In terms of Rule 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Divisional Superintendent Workshop (Pakistan Railways), Divisional Superintendent
Office of the Divisional Superintendent Workshops, Pakistan Railways, Moghalpura, Lahore.
+92-333-408-2711
pemdsw2020@gmail.com
Sections of Prequalifica¬tion Documents
The following specific data for the Prequalification of Applicants shall complement, supplement, or amend the provisions in the Instructions to Applicants (ITA). Whenever there is a conflict, the provisions herein shall prevail over those in ITA.
PDS Clause No
ITA No
Amendments of, and Supplements to, Clauses in the Instructions to Applicants
PDS Clause No 1
ITA No 1.1
Identification Number of the Invitation for Prequalification: P207729
The Procuring Agency is: Divisional Superintendent Workshop (Pakistan Railways)
List of Contracts:
See section items and Lots
PDS Clause No 2
ITA No 2.1
The name of Procuring Agency is: Divisional Superintendent Workshop (Pakistan Railways)
The name of Project / Procurement is: 197-S/1/8903/11-2026 (Prequalification of firms for Procurement of Liquid Oxygen)
PDS Clause No 3
ITA No 4.2
Maximum number of members in a Joint Venture (JV): 3
PDS Clause No 4
ITA No 4.5
A list of debarred firms and individuals is available on PPRA website:https://ppra.gov.pk
PDS Clause No 5
ITA No 7.1
For clarification, the Applicant shall seek clarifications through: EPADS v2.0
PDS Clause No 6
ITA No 7.1 & 8.2
Information related to Prequalification shall be published on: EPADS v2.0
PDS Clause No 7
ITA No 7.2
Pre-Application Meeting: Clarification Date: Wednesday, December 2, 2026
PDS Clause No 8
ITA No 10.1
This Prequalification Document has been issued in the language: English
PDS Clause No 9
ITA No 11.1(d)
Additional documents to be submitted through EPADS v2.0:
PDS Clause No 10
ITA No 14.2
Source for determining exchange rates: Not Applicable
PDS Clause No 11
ITA No 16.1
Deadline for Application Submission:
Day: Saturday
Date: Saturday, December 5, 2026
Time: 10:30 AM
PDS Clause No 12
ITA No 17.1
Opening of Applications shall be conducted through: EPADS v2.0
Day: Saturday
Date: Saturday, December 5, 2026
Time: 11:00 AM
Virtual participation link: https://vendors.epads.gov.pk/
PDS Clause No 13
ITA No 21.1
Margin of Domestic Preference: Not Applicable
(Applicable only if authorized in Procurement Plan)
PDS Clause No 14
ITA No 29.1
Prequalification-related complaints / grievances shall be submitted in writing through: EPADS v2.0
A complaint may challenge:
All Active Taxpayers shall be eligible to participate in the procurement process, unless expressly excluded or otherwise restricted under the Eligibility Criteria specified by the Procuring Agency.
| Required Registration |
|---|
|
NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) FBR (GSTN) |
| Eligibility Criteria | Document |
|---|---|
| As required in prequalification requirements matrix | No |
| As per DSW & PR requirements | No |
| Applicant Name, Address, Contact Details & Legal Status (Proprietor/partners/directors) | Yes |
| NTN Certificate | Yes |
| GSTN Certificate | Yes |
| ATL / Active Status (NTN & GST) | Yes |
| Registration with relevant authorities | Yes |
| Item Description & Stock Code number with signatures of applicant along with name and designation | Yes |
| Declaration (with name, signatures & designation): Information is correct & consent for verification / inquiries. | Yes |
| Declaration (with name, signatures & designation): Acceptance of committee decisions, instructions & consequences of false information | Yes |
Quality Based Selection (QBS)
Weightage (Without Financial Criteria)
| Technical Evaluation % |
|---|
| 100 |
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 70 | |
| ISO CERTIFICATIONS (Valid certificate number & Validity) | ||
| ISO 9001:2015 Quality Management System (Qualitative)(Doc Required) | 4 | |
| ISO 14001:2015 Environmental Management System (Qualitative)(Doc Required) | 4 | |
| ISO 45001:2018 Occupational Health & Safety (Qualitative)(Doc Required) | 4 | |
| SECP registration (Optional) (Qualitative)(Doc Required) | 3 | |
| Regulatory Certification and Experience (PSQCA) | ||
| PSQCA Registration Valid Certificate (Mandatory: Minimum 1 year validity) [last year valid registration = 1 mark; each additional year = +1 mark. (Max 5 marks)] (Qualitative)(Doc Required) | 5 | |
| Plant & Machinery | ||
| Air Purification Unit (Qualitative)(Doc Required) | 1 | |
| Safety System (Qualitative)(Doc Required) | 1 | |
| Cryogenic Pump (Qualitative)(Doc Required) | 1 | |
| High Purification Unit (Qualitative)(Doc Required) | 1 | |
| Specialized Cryogenic Tanker (Qualitative)(Doc Required) | 1 | |
| Main heat Exchanger (Qualitative)(Doc Required) | 1 | |
| Air Separation Column (Qualitative)(Doc Required) | 1 | |
| Filling /Loading system (Qualitative)(Doc Required) | 1 | |
| Storage tank capacity : Minumum 5000 Ltr capacity per day as per P.R Required [Min 5000 Ltr=3 Marks; each additional 5000 Ltr=2 Marks up to Max 7 marks (Qualitative)(Doc Required) | 7 | |
| Supply Details (Purchase orders executed during last 5 Year. [ Description of supply: organization / Client, value & P.O copies (Min 3 Year supply required (+1 marks /yr: max 5) ] | ||
| 1. FY 2025-26 (Qualitative)(Doc Required) | 1 | |
| FY 2024-25 (Qualitative)(Doc Required) | 1 | |
| FY 2023-24 (Qualitative)(Doc Required) | 1 | |
| FY 2022-23 (Qualitative)(Doc Required) | 1 | |
| FY 2021-22 (Qualitative)(Doc Required) | 1 | |
| Testing Facilities | ||
| Manufacturer Certificate / Certificate of Conformity (Qualitative)(Doc Required) | 2 | |
| Desgin and Prsssure Vessel certificate (Qualitative)(Doc Required) | 2 | |
| Hydraulic /Pressure Test Certificate (Qualitative)(Doc Required) | 2 | |
| Vacuum / Installation Test Record (Qualitative)(Doc Required) | 2 | |
| Safety /Relief valve Certificate (Qualitative)(Doc Required) | 2 | |
| Financial Postion (Annual turnover for Last 5 Years) | ||
| Average Turover More than 100 million PKR= 3 marks [+1 mark for each 10 Million above 100 Million max 10 Marks allowed) (Qualitative)(Doc Required) | 10 | |
| Oxygen Tank Installation & cryogenic Competence | ||
| Successful installation & commissioning of Cryogenic Liquid oxygen storage Tanks: [ 2 Marks per verfied Tank Installation (Minimum 2 installation =4 marks : Max =10 marks (Qualitative)(Doc Required) | 10 | |
| Factory Visit by Technical Committee of Pakistan Railways | ||
| Technical Committee's factory visit / evaluation Site / facility assessment and marks awarded by the committee (Qualitative)(Doc Required) | 30 | |