In terms of Rules 65 of Public Procurement Rules, 2026 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and also available on EPADS v2.0 as well as Authority’s website at (www.ppra.gov.pk).
Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer
Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
+92-333-864-5341
repmangla@gmail.com
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
BDS Clause Number
ITB Number
Amendments of, and Supplements to, Clauses in the Instruction to Bidders
BDS Clause Number 1
ITB Number 1.1
Name of Procuring Agency: Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water))
The subject of procurement is: ITR-1092-3 Installation of Perimeter Electric Fencing at Warehouse Power Station Mangla
Expected commencement date: Monday, January 11, 2027
BDS Clause Number 2
ITB Number 2.1
Financial year for the operations of the Procuring Agency: 2026-27
Name and identification number of the Contract: P196827
BDS Clause Number 3
ITB Number 4
JV/Consortium or Association Allowed: No
Number of JV/Consortium Members: Nil
BDS Clause Number 4
ITB Number 7.1
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Monday, December 7, 2026
BDS Clause Number 5
ITB Number 8.1
Any addendum, in case issued, shall be published on Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)) website and on EPADS v2.0.
BDS Clause Number 6
ITB Number9.1
List of documents required along with the bid: No
BDS Clause Number 7
ITB Number 11.1
The qualification criteria to establish the supply / production capability of the bidder.
see Eligibility Criteria
BDS Clause Number 8
ITB Number 7.1
Services and Their related documents:
See section Required Services and Scope of Work
BDS Clause Number 9
ITB Number 13.1 & 13.2
Price schedule will be provided according to the format defined and acquired.
see section price schedule.
BDS Clause Number 10
ITB Number 7.1
Specifications:
see section of specifications.
BDS Clause Number 11
ITB Number 13.5
The price shall be Fixed.
BDS Clause Number 12
ITB Number 15.1
Currency of the Bids shall be : PKR
BDS Clause Number 13
ITB Number 16.1
The Bids/Bid Validity period shall be: 120 Days
BDS Clause Number 14
ITB Number 17.1
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given
Instrument of Bid Security Shall be in the Name of : Water and Power Development Authority (Chief Engineer (Power)) Mangla
The Bid Security shall be in the form of: Banker's Cheque, Call at Deposit, Bank Guarantee
BDS Clause Number 15
ITB Number 17.3
The Bids security shall be valid for twenty-eight (28) days beyond the expiry of the Bids validity period specified in the bidding documents, for example the bid validity is 180 days so the bid security shall be valid for 180+28 = 208 days.
BDS Clause Number 16
ITB Number 18.1
Alternative Bids to the requirements of the bidding documents will not be permitted.
BDS Clause Number 17
ITB Number 21.1
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following;
Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
Bids that are not submitted on EPADS v2.0 shall be disqualified.
The deadline for Bids submission is: Thursday, December 10, 2026 10:00 AM
BDS Clause Number 18
ITB Number 26.1
The Bids opening shall take place on EPADS v2.0.
Day : Thursday
Date: Thursday, December 10, 2026
Time : 10:30 AM
BDS Clause Number 19
ITB Number 32.1
Selection technique adopted will be: Least Cost Based Selection (LCBS)
see Evaluation Criteria
BDS Clause Number 20
ITB Number 49.1
The Performance guarantee shall: 10.00%.
The Performance Guarantee shall be acceptable in the form of: Banker's Cheque, Call at Deposit, Bank Guarantee
BDS Clause Number 21
ITB Number 51.1
Arbitrator shall be appointed by mutual consent of the both parties.
BDS Clause Number 22
ITB Number 53.1
Grievence against this procurement shall be submitted online on EPADS v2.0.
All Active Taxpayers shall be eligible to participate in the procurement process, unless expressly excluded or otherwise restricted under the Eligibility Criteria specified by the Procuring Agency.
| Required Registration |
|---|
|
NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) FBR (GSTN) |
Least Cost Based Selection (LCBS)
Lot Title : Installation of Perimeter Electric Fence
Bid Security : 60000 PKR
| Position | Delivery Schedule | Quantity |
|---|---|---|
| High-Tensile Stainless Steel Conductor Wire (2.5 mm, 8-line system; spacing 4–6 | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: Days 45Quantity: 7200/ft |
7200/ft |
| Fence Support Posts (MS square pipe, powder-coated, anti-tamper, wall-top mounting) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: Days 45Quantity: 80/Qty |
80/Qty |
| Heavy-Duty UV Insulators (line, corner, strain; UV & weather stable) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 762/Qty |
762/Qty |
| High-Strength Tensioners / Strainers (galvanized) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 64/Qty |
64/Qty |
| Corner & End Post Reinforcement Bracing Sets (heavy-duty) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 15/set |
15/set |
| Premium High-Voltage Energizer — 12–14 J, IP65, LCD diagnostics, dual alarm outputs, GSM SMS alerts, tamper detection (mains-powered) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/Qty |
1/Qty |
| Backup Battery — 12V, 150Ah deep-cycle, maintenance-free, weatherproof enclosure | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/Qty |
1/Qty |
| Alarm System (high-intensity Siren + Strobe + GSM notification module & wiring) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/bundle |
1/bundle |
| Earthing System (3× copper-bonded rods, 25×3 mm copper strip, clamps, earthing compound; test ≤4Ω) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/bundle |
1/bundle |
| Wiring, Conduits, Flexible Protective Ducts, Cable Trays (HV & LV), Junction Boxes (IP55) — mains integration | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/bundle |
1/bundle |
| Lightning / Surge Protection Kit (Class-1 MOV arrester, bonding kit, IP65 enclosure) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/Qty |
1/Qty |
| Warning Signage (reflective UV polycarbonate, bilingual Urdu & English) | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: Days 45Quantity: 37/Qty |
37/Qty |
| Labour, Transport, Site Mobilization, Contingency & Miscellaneous Charges | Address: Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province). Schedule: 45 DaysQuantity: 1/bundle |
1/bundle |
No
Lot Title : Installation of Perimeter Electric Fence
Position: High-Tensile Stainless Steel Conductor Wire (2.5 mm, 8-line system; spacing 4–6
Specifications / Requirements:
Material: Stainless Steel SS-304, corrosion-resistant, tensile strength ≥ 900 N/mm². Electrical Properties: Resistance ≤ 0.09 Ω/m, rated for continuous high voltage up to 10 kV, capable of handling energizer output safely. Mechanical Properties: Stretch <1% under maximum tension, fatigue-resistant, no sagging over time. Environmental: UV-stable, resistant to rain, humidity, temperature range −10°C to +55°C. Installation: Four parallel wires, 1 ft vertical spacing, mounted on insulators. Wires must never contact metal posts or adjacent conductive surfaces. Maintenance: Inspect annually for corrosion, tension, and continuity. Quantity: 7,200 ftPosition: Fence Support Posts (MS square pipe, powder-coated, anti-tamper, wall-top mounting)
Specifications / Requirements:
Material: Mild Steel, 50×50 mm square pipe, wall thickness ≥ 2.5 mm. Finish: UV-stable, powder-coated for corrosion resistance. Mounting Accessories: Anti-tamper brackets, bolts, washers, and base plates. Mechanical Requirements: Must withstand wind pressure ≥ 120 km/h, maintain vertical alignment, carry full wire tension. Safety: Posts must be free of sharp edges; brackets must prevent conductor slippage. Quantity: 80 Nos.Position: Heavy-Duty UV Insulators (line, corner, strain; UV & weather stable)
Specifications / Requirements:
UV-stable Polycarbonate or Nylon, dielectric strength ≥ 20 kV, non-conductive. Types: Line, corner, strain. Design: Withstands mechanical tension of conductor wire ≥ 200 kg. Installation: Insulators must securely hold wires without slipping, prevent wire contact with posts. Quantity: 762 pcs. Durability: Rated for >10 years outdoor exposure.Position: High-Strength Tensioners / Strainers (galvanized)
Specifications / Requirements:
Material: Galvanized steel, anti-corrosion finish. Design: Screw/rachet type for fine tensioning of each wire. Load Capacity: ≥ 200 kg tensile force. Environmental: Weatherproof, UV and corrosion resistant. Installation: Must maintain correct wire tension, allow future adjustments, prevent conductor deformation. Quantity: 64 pcs.Position: Corner & End Post Reinforcement Bracing Sets (heavy-duty)
Specifications / Requirements:
Galvanized steel struts, ratchet or screw assemblies. Design: Suitable for corner and end posts to prevent sagging or movement. Mechanical Requirements: Must support cumulative wire tension ≥ 1,000 kg per corner. Installation: Correctly anchored to wall-top, using bolts and brackets; must not allow movement of posts. Quantity: 15 sets.Position: Premium High-Voltage Energizer — 12–14 J, IP65, LCD diagnostics, dual alarm outputs, GSM SMS alerts, tamper detection (mains-powered)
Specifications / Requirements:
Source: 230V AC mains, 50 Hz. Output: 12–14 Joules, peak voltage ≥ 7 kV. Enclosure: IP55 weatherproof, UV-stable, tamper-resistant. Features: LCD display for output monitoring, LED status indicators, alarm dry-contact output. Compliance: IEC 60335-2-76, CE-marked. Installation: Secure, ventilated mounting on wall-top post or adjacent structure, proper earthing required. Mobile SMS Alert System (GSM Module): • Sends SMS alerts to up to 3 registered mobile numbers. • Alerts include: o Power Failure o Fence Breach / Line Cut o Low Output Voltage o Energizer Tampering o System Restart • Supports local GSM SIM networks (Jazz / Zong / Telenor). • Includes antenna for stable signal performance. Maintenance: Annual inspection, cleaning, and voltage verification.Position: Backup Battery — 12V, 150Ah deep-cycle, maintenance-free, weatherproof enclosure
Specifications / Requirements:
Type: 12V deep-cycle AGM/VRLA, 150Ah. Enclosure: Vented, weatherproof, UV-resistant. Purpose: Provides temporary backup during mains outages. Integration: Automatic switch-over to energizer; battery cables rated for load. Maintenance: Check electrolyte (if VRLA), voltage level, connections annually.Position: Alarm System (high-intensity Siren + Strobe + GSM notification module & wiring)
Specifications / Requirements:
Components: Siren ≥ 50 W, flashing beacon, GSM module for mobile alert. Integration: Dry-contact from energizer; triggers on voltage drop, fence cut, or tamper. Wiring: Low-voltage, flame-retardant, UV-resistant conduit. Operation: Continuous monitoring; must sound local alarm and send remote alert. Maintenance: Test monthly for audible/visual and GSM alert.Position: Earthing System (3× copper-bonded rods, 25×3 mm copper strip, clamps, earthing compound; test ≤4Ω)
Specifications / Requirements:
Components: 3 copper-bonded rods ≥ 2.4 m, 25 mm² copper strip, clamps, earthing compound. Electrical Requirement: Resistance ≤ 4 Ω. Installation: Driven vertically into ground; rods connected with copper strip; bonded to energizer and lightning protection. Testing: Measure resistance before commissioning; document test certificate.Position: Wiring, Conduits, Flexible Protective Ducts, Cable Trays (HV & LV), Junction Boxes (IP55) — mains integration
Specifications / Requirements:
Wiring: HV wires insulated, UV-stable, flame-retardant; low-voltage cables for alarms. Conduits & Trays: PVC/HDPE, UV-protected, wall-mounted securely. Junction Boxes: IP55, lockable, weatherproof. Scope: Connect energizer, optional battery, alarm, and lightning protection safely. Safety: All wiring must follow local electrical codes and IEC standards.Position: Lightning / Surge Protection Kit (Class-1 MOV arrester, bonding kit, IP65 enclosure)
Specifications / Requirements:
Components: MOV surge arresters, bonding conductors, IP65 enclosure. Function: Protect energizer and fence from lightning and voltage spikes. Installation: Bonded to earthing system, shortest possible lead length, proper grounding. Testing: Verify functionality after installation.Position: Warning Signage (reflective UV polycarbonate, bilingual Urdu & English)
Specifications / Requirements:
Material: UV-stable polycarbonate, weatherproof. Size: ≥ 30×20 cm. Content: “High Voltage / Electric Fence” in English & Urdu. Placement: Every 30 ft along wall-top, at gates, corners, and entry points. Quantity: 37 pcs.Position: Labour, Transport, Site Mobilization, Contingency & Miscellaneous Charges
Specifications / Requirements:
• Installation of all posts, wires, insulators, tensioners, energizer, alarm interface, earthing system, warning signage, and associated accessories. • Execution of fencing alignment, including site preparation, removal of obstructions, and clearance of trees/vegetation along the wall boundary where required. • Line tensioning, reinforcement of corner/end posts, strain balancing, continuity check, voltage testing, alarm test, and earthing resistance measurement. • Electrical integration of energizer with mains supply and configuration of alarm dry-contact output. • Material transport, shifting along the perimeter, and safe handling/hoisting. • Supervision by qualified electric-fence engineers/technicians during installation, testing, and commissioning. • Documentation: As-Built installation drawings, system layout, test certificates (including earthing and voltage reports), component datasheets, and commissioning report. • General provision for minor incidental works required to complete the installation to the required operational standard.Installation of Perimeter Electric Fencing at Warehouse, Power Station Mangla
|
Sr. No. |
Item |
Technical Specifications / Scope |
|
1 |
High-Tensile Stainless Steel Conductor Wire (2.5 mm, 8-line system; spacing 4–6") |
Material: Stainless Steel SS-304, corrosion-resistant, tensile strength ≥ 900 N/mm². Electrical Properties: Resistance ≤ 0.09 Ω/m, rated for continuous high voltage up to 10 kV, capable of handling energizer output safely. Mechanical Properties: Stretch <1% under maximum tension, fatigue-resistant, no sagging over time. Environmental: UV-stable, resistant to rain, humidity, temperature range −10°C to +55°C. Installation: Four parallel wires, 1 ft vertical spacing, mounted on insulators. Wires must never contact metal posts or adjacent conductive surfaces. Maintenance: Inspect annually for corrosion, tension, and continuity. Quantity: 7,200 ft |
|
2 |
Fence Support Posts (MS square pipe, powder-coated, anti-tamper, wall-top mounting) |
Material: Mild Steel, 50×50 mm square pipe, wall thickness ≥ 2.5 mm. Finish: UV-stable, powder-coated for corrosion resistance. Mounting Accessories: Anti-tamper brackets, bolts, washers, and base plates. Mechanical Requirements: Must withstand wind pressure ≥ 120 km/h, maintain vertical alignment, carry full wire tension. Safety: Posts must be free of sharp edges; brackets must prevent conductor slippage. Quantity: 80 Nos. |
|
3 |
Heavy-Duty UV Insulators (line, corner, strain; UV & weather stable) |
Material: UV-stable Polycarbonate or Nylon, dielectric strength ≥ 20 kV, non-conductive. Types: Line, corner, strain. Design: Withstands mechanical tension of conductor wire ≥ 200 kg. Installation: Insulators must securely hold wires without slipping, prevent wire contact with posts. Quantity: 762 pcs. Durability: Rated for >10 years outdoor exposure. |
|
4 |
High-Strength Tensioners / Strainers (galvanized) |
Material: Galvanized steel, anti-corrosion finish. Design: Screw/rachet type for fine tensioning of each wire. Load Capacity: ≥ 200 kg tensile force. Environmental: Weatherproof, UV and corrosion resistant. Installation: Must maintain correct wire tension, allow future adjustments, prevent conductor deformation. Quantity: 64 pcs. |
|
5 |
Corner & End Post Reinforcement Bracing Sets (heavy-duty) |
Material: Galvanized steel struts, ratchet or screw assemblies. Design: Suitable for corner and end posts to prevent sagging or movement. Mechanical Requirements: Must support cumulative wire tension ≥ 1,000 kg per corner. Installation: Correctly anchored to wall-top, using bolts and brackets; must not allow movement of posts. Quantity: 15 sets. |
|
6 |
Premium High-Voltage Energizer — 12–14 J, IP65, LCD diagnostics, dual alarm outputs, GSM SMS alerts, tamper detection (mains-powered) |
Power Source: 230V AC mains, 50 Hz. Output: 12–14 Joules, peak voltage ≥ 7 kV. Enclosure: IP55 weatherproof, UV-stable, tamper-resistant. Features: LCD display for output monitoring, LED status indicators, alarm dry-contact output. Compliance: IEC 60335-2-76, CE-marked. Installation: Secure, ventilated mounting on wall-top post or adjacent structure, proper earthing required. Mobile SMS Alert System (GSM Module):
Maintenance: Annual inspection, cleaning, and voltage verification. |
|
7 |
Backup Battery — 12V, 150Ah deep-cycle, maintenance-free, weatherproof enclosure |
Type: 12V deep-cycle AGM/VRLA, 150Ah. Enclosure: Vented, weatherproof, UV-resistant. Purpose: Provides temporary backup during mains outages. Integration: Automatic switch-over to energizer; battery cables rated for load. Maintenance: Check electrolyte (if VRLA), voltage level, connections annually. |
|
8 |
Alarm System (high-intensity Siren + Strobe + GSM notification module & wiring) |
Components: Siren ≥ 50 W, flashing beacon, GSM module for mobile alert. Integration: Dry-contact from energizer; triggers on voltage drop, fence cut, or tamper. Wiring: Low-voltage, flame-retardant, UV-resistant conduit. Operation: Continuous monitoring; must sound local alarm and send remote alert. Maintenance: Test monthly for audible/visual and GSM alert. |
|
9 |
Earthing System (3× copper-bonded rods, 25×3 mm copper strip, clamps, earthing compound; test ≤4Ω) |
Components: 3 copper-bonded rods ≥ 2.4 m, 25 mm² copper strip, clamps, earthing compound. Electrical Requirement: Resistance ≤ 4 Ω. Installation: Driven vertically into ground; rods connected with copper strip; bonded to energizer and lightning protection. Testing: Measure resistance before commissioning; document test certificate. |
|
10 |
Wiring, Conduits, Flexible Protective Ducts, Cable Trays (HV & LV), Junction Boxes (IP55) — mains integration |
Wiring: HV wires insulated, UV-stable, flame-retardant; low-voltage cables for alarms. Conduits & Trays: PVC/HDPE, UV-protected, wall-mounted securely. Junction Boxes: IP55, lockable, weatherproof. Scope: Connect energizer, optional battery, alarm, and lightning protection safely. Safety: All wiring must follow local electrical codes and IEC standards. |
|
11 |
Lightning / Surge Protection Kit (Class-1 MOV arrester, bonding kit, IP65 enclosure) |
Components: MOV surge arresters, bonding conductors, IP65 enclosure. Function: Protect energizer and fence from lightning and voltage spikes. Installation: Bonded to earthing system, shortest possible lead length, proper grounding. Testing: Verify functionality after installation. |
|
12 |
Warning Signage (reflective UV polycarbonate, bilingual Urdu & English) |
Material: UV-stable polycarbonate, weatherproof. Size: ≥ 30×20 cm. Content: “High Voltage / Electric Fence” in English & Urdu. Placement: Every 30 ft along wall-top, at gates, corners, and entry points. Quantity: 37 pcs. |
|
13 |
Labour, Transport, Site Mobilization & Documentation + Contingency and other misc. charges |
• Installation of all posts, wires, insulators, tensioners, energizer, alarm interface, earthing system, warning signage, and associated accessories. |
Installation of Perimeter Electric Fencing at Warehouse, Power Station Mangla
For Individual Positions
| # | Position Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Definitions
The Procuring Agency is: Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
Contractor is:
The title of the subject procurement is:ITR-1092-3 Installation of Perimeter Electric Fencing at Warehouse Power Station Mangla
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer
Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
+92-333-864-5341
repmangla@gmail.com
Contractor/ Bidder:
[Name, address and telephone number].
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer
Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
+92-333-864-5341
repmangla@gmail.com
For the Bidder:
Name: ………………………
Designation: ……………..
Address: ……………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/ Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ………………….
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 16.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.25% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
Instrument of Performance Guarantee shall be in the Name of : Water and Power Development Authority (Chief Engineer (Power)) Mangla
The amount of performance guarantee shall be 10.00% of the contract price in acceptable form of Banker's Cheque, Call at Deposit, Bank Guarantee
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
For being Brand New, bearing relevant reference numbers of the equipment (Certificate from supplier)
For Physical Fitness having No Damages (Certificate from supplier)
For the Country of Origin as quoted by the Supplier (Certificate from manufacturer)
For conformance to specifications and performance parameters, through Prior to delivery inspection (Inspection Report by Procurement Committee / Inspection Team)
For successful operation at site after complete installation, testing and commissioning of the equipment (Installation, Testing and Commissioning Report by Procurement Committee / Inspection Team)
Copies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount;
Original and two copies of the usual transport document (for example, a negotiable bill of lading, a non-negotiable sea waybill, an inland waterway document, an air waybill, a railway consignment note, a road consignment note, or a multimodal transport document) which the buyer may require to take the goods;
Copies of the packing list identifying contents of each package;
Insurance Certificate;
Manufacturer’s or Supplier’s Valid Warranty Certificate;
Inspection Certificate issued by the Nominated Inspection Agency (if any), and the Supplier’s Factory Inspection Report;
Certificate of Origin.
The above documents would be required even if the equipment has already been imported and is available with the supplier ex-stock
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract unless they otherwise agree that the Authority shall pay the Bidder any monies due to the Bidder.
Arbitrator’s fee:
The fee shall be specified in Pak Rupees, as determined by the Arbitrator, which shall be shared equally by both parties.
Appointing Authority for Arbitrator:
By the Mutual Consent or in accordance with the provisions of Arbitration Act, 1940, in case the parties fail to reach a consensus on the name of sole arbitrator, any party may submit an application to the Chief Justice Islamabad High Court for appointment of sole arbitrator. The Chief Justice IHC may appoint a former judge of any High Court or Supreme Court as the sole arbitrator to resolve the dispute between the parties.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder who is a national of the Islamic Republic of Pakistan arising in connection with the present Contract shall be referred to adjudication or arbitration in accordance with the laws of the Islamic Republic of Pakistan including Arbitration Act 1940, however above provision shall prevail in referring the case to the Arbitrator.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place of arbitration shall be at Islamabad. The award of the arbitrator shall be final and shall be binding on the parties.
Date: [insert date (as day, month and year)]
Bid No.:P196827
To: Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., ITR-1092-3 Installation of Perimeter Electric Fencing at Warehouse Power Station Mangla (P196827) and has accepted a Bids by the Bidder for the provision of Services in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: Water and Power Development Authority (Chief Engineer (Power)) Mangla (Water and Power Development Authority (WAPDA) / Member (Water)), Resident Engineer Power Station, Mirpur Tehsil, Mirpur District (District), Mirpur Division (Division), Azad Jammu and Kashmir (AJK) (Province).
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Non-Consultancy Services(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}
Bidder should have experience of minimum 02 years of same like works completed successfully. Documentary evidence should be attach herewith.