In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
National Bank of Pakistan (Engineering), Sr. Vice President
Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
+92-213-890-2590
teemar@nbp.com.pk
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: National Bank of Pakistan (Engineering) The subject of procurement is: MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION Expected commencement date: Monday, November 30, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P128299 |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Wednesday, October 21, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on National Bank of Pakistan (Engineering) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid:
|
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 360 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Banker's Cheque |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Monday, October 26, 2026 11:00 AM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Monday Date: October 26, 2026 Time : 11:30 AM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 0%. The Performance Guarantee shall be acceptable in the form of: Nil |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Sole Proprietorship Partnership Firm Company (Private Limited) | NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) FBR (GSTN) PEC |
| Eligibility Criteria | Document |
|---|---|
| The bidder should have an active status on FBR Active Taxpayer List and with Provincial Revenue Board. | Yes |
| Valid registration in Pakistan Engineering Council in financial category C-6 or above with Specialization Code CE-10 & EE-04 on bidding date. | Yes |
| An Undertaking/Affidavit by the bidder that he has not been blacklisted and hence debarred due to involvement in corrupt and fraudulent practices, or performance failure or due to breach of bid securing declaration by any Organization/ Department / Institution in the past, on E Stamp Paper.of Rs. 500/- | Yes |
| Sindh Revenue Board (SRB) Tax (or relevant province/federal Board registration Certificate) | Yes |
| Three ( 03) number of similar contracts that have been satisfactorily completed as a prime contractor during last 03 years of at least Three 3.0 (M) | Yes |
Least Cost Based Selection (LCBS)
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION | Address: NBP AIB GHARO BRANCH (0187) HYDERABAD REGION Schedule: 90 Days Quantity: 1/job |
1/job | 150000 PKR |
No
Jobs Without Lots :
Job: MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION
Specifications / Requirements:
| Sr. No | S.NO | DESCRIPTION | UNIT | QTY | RATE | AMOUNT |
|---|---|---|---|---|---|---|
| 1 | 1 | DISMANTLING WORKS (where required) | ||||
| 2 | Dismantling and removing of existing masonry walls, False ceiling, tile Flooring/walls, Doors, Windows, Glass work,electrical, plumbing fitting fitting / fixtures, front boudry wall and grills and any other material etc. complete in all respects as per drawings. | Job | 1 | 30000 | 30000 | |
| 3 | 2 | Shifting of existing branch furniture, heavy duty safe and fire proof almirah of strong room/ locker room including labor, equipment, chain pully etc. Complete in all respect. | Job | 1 | 25000 | 25000 |
| 4 | 3 | REINFORCEMENT CEMENT CONCRETE 3000 PSI | ||||
| 5 | Provide, mix, place and vibrate reinforcement cement concrete in the volumetrix mix. 1:2:4 using one part of op cement to 2- part of 50 % lawrancepur and 50 % chenab sand and 4-parts of sargodha crush nominal size 3/4'' and down mesh with min. cube crushing strength of 3000 psi at 28 days finishing the necked surface and curing etc, including water tight finishing the necked surfaces and curing etc, from work including its sub-sequent removal, complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer. | |||||
| 6 | I) R.C.C Walls for Vault. | cft | 250 | 750 | 187500 | |
| 7 | 4 | STEEL REINFORCEMENT | ||||
| 8 | P/F Grade 60 steel reinforcement deformed bars at any floor with minimum yield strength of 60000 psi as per ASTM standards A-615, including cost of binding wire of 16-SWG, chairs. (Wastage of bars, Over laps etc. is to be Contractors accounts). | kgs | 650 | 575 | 373750 | |
| 9 | 5 | BRICK MASONARY WORK | ||||
| 10 | Providing and laying Block /brick masonary with 1:4 cement sand mortar in super structure, incluing raking out joints, scaffolding, curing, drilling for walls/ Ramps where required complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer. | |||||
| 11 | 4" or 4-1/2'' (114 mm) Thick | Sft | 100 | 125 | 12500 | |
| 12 | 6 | PLASTER WORK | ||||
| 13 | Providing and applying Plaster (thickness and cement / sand ratio as indicate in sub items below) including making edges and corners, curing, scaffolding etc, complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer. | |||||
| 14 | 12mm Thick in (1:4) on walls | Sft | 650 | 80 | 52000 | |
| 15 | 19mm Thick in 1:3 on stairs soffit / ceiling | Sft | 100 | 56 | 5600 | |
| 16 | 7 | P.C.C (1:4:8) UNDER FLOOR | ||||
| 17 | Providing and laying under floor cement concrete of the nominal mixes by volume as indicated, using 1-1/2'' down guage stone ballast as coarse aggregate, including formwork and its removal, compacting, curing etc, complete in all respects as per drawing, specifications and as directed by the Consultant / Engineer. | Cft | 100 | 220 | 22000 | |
| 18 | 8 | GRANITE SKIRTING | ||||
| 19 | Providing and laying Skirting of Porcelain tiles 100mm X 600mm/1200mm (Conoliaen Brown) 11mm thick of takceram tile imported made (Chaina or equavilent including base mortar (2-1/2" average) thick c.c and matching colour grouting, cement slurry for fixing of tiles, complete in all respects as per drawings, specifications and as directed by the Engineer. | Rft | 50 | 315 | 15750 | |
| 20 | 9 | WOODEN DOORS | ||||
| 21 | Supply of WOODEN DOOR ( WD- 1A ), made with 38mm thick sandwich chipboard (tactile sheet 4024) with 19mm thick soft wood vertical rail both sides covered with approved, 9mm thick mahagni wood edging, finish with clear NC lacquer polish, including door frame of 16 SWG GI sheet with red oxide coat covered with approved laminate/door boarder and hardwares i-e hinges, imported door lock and door stopper etc, complete with hard ware. And complete with all respect as per design. | Sft | 21 | 1750 | 36750 | |
| 22 | 10 | Removing and re-fixing of 12mm glass partion including with frosting paper in pattern as shown on drawings, with approved aluminum H section/ solid oak wooden section 2'' thick finished with lacqure polish approved shade as frame on top and bottom and sides and all necessary joinery details complete in all respects | Sft | 200 | 200 | 40000 |
| 23 | 11 | INTERNALPAINT WORKS | ||||
| 24 | Providing and applying Paint on internal/ External walls of ICI or Berger including rubbing with sand stone, filling the uneven surfaces with putty, rubbing with sand paper and preparation of surface perfect in all respects, applying one coat of primer on prepared surface of plastered and finish paint coats as indicated in sub items, complete in all respects as per drawings. | |||||
| 25 | Plastic Emulsion Paint ash white (on Internal walls) | Sft | 1200 | 60 | 72000 | |
| 26 | Enamel paint | Sft | 500 | 45 | 22500 | |
| 27 | 12 | Providing and applying Three coats of ICI deluxe distemper paint for roof/ ceiling after scraping, sand papering, plain surface complete with all material labour, equipment scaffolding etc As per entire satisfaction of Regional Engineer/ Engineer Incharge. | Sft | 100 | 35 | 3500 |
| 28 | 13 | Wooden CABINETS ( Record Room) | ||||
| 29 | P/fixing of wooden filling cabinets low and full height at any height made with 16mm MDF laminated 4025 with edging made of laminated 4025 veneer properly fixed and Internal carcass in 16mm thick lamination chipboard # 7056 , includindg approved handles, hings and shelf approved drawing and design. Complete in all respect. (Size upto 4'x8' approx.) | No. | 6 | 42000 | 252000 | |
| 30 | 14 | Wooden CABINETS ( Banking Hall) | ||||
| 31 | P/fixing of wooden filling cabinets low and full height at any height made with 16mm MDF laminated 4024 tactile sheet with edging made of laminated tactile sheet veneer properly fixed and Internal carcass in 16mm thick lamination chipboard # 7056 , includindg approved handles, hings and shelf approved drawing and design. Complete in all respect. (Size upto 4'x8' approx.) | No. | 3 | 42000 | 126000 | |
| 32 | 15 | KITCHEN CABINETS | ||||
| 33 | P/fixing of wooden filling cabinets low and full height at any height made with 16mm MDF laminated 7419 with edging made of laminated 7419 veneer properly fixed and Internal carcass in 16mm thick lamination chipboard # 7056 , includindg approved handles, hings and shelf approved drawing and design. Complete in all respect. (Size upto 2.5'x6' approx.) | No. | 1 | 18000 | 18000 | |
| 34 | 16 | FALSE CEILING | ||||
| 35 | Providing and fixing 7.5mm thick Lamination gypsum tile 600mm x 600mm False including hanging system(Groove), making opening for lights or diffuser complete in all respects as per drawing, specifications and as directed by the Consultant / Engineer. | Sft | 800 | 140 | 112000 | |
| 36 | 17 | CORNICE | ||||
| 37 | Providing and fixing 11mm thick and 75mm high MDF Cornice tactile sheet architrave on wall and applying of approved paint, including joinery detail complete in all respects as per drawing, specifications and as directed by the Consultant / Engineer. | Rft | 150 | 170 | 25500 | |
| 38 | 18 | BLINDS | ||||
| 39 | Providing and fixing imported sunthetic fibre roller Blinds according to the instructions of the manufacturer, complete in all respects as per drawing, specifications and as directed by the Consultant / Engineer. | Sft | 30 | 450 | 13500 | |
| 40 | 19 | Repair and service of G.I shutter grill including oiling / greesing, addition and alteration of MS angles and fence, service of bearing box and locking system etc. Complete in all respect. | Sft | 50 | 400 | 20000 |
| 41 | 20 | WALL CLADDING | ||||
| 42 | Providing and fixing of wall cladding with 17mm thick approved design and shade laminated tectile sheet # 4025 made by alnoor or equivalent with partal wood frame size 2"x1" at 2' C/C, having vertical stripes 1" wide x 3/4" thick @ 1" c/c spacing finished with maching color lipping best quality. complete in all respect as per specification or as directed by the Engineer Incharge. | Sft | 170 | 1200 | 204000 | |
| 43 | 21 | TERMITE PROOFING | ||||
| 44 | P/A Termite proofing and rat killer spry or chemicals best quality imported approved before application inside Branch/warehouse/ Rooms with warrenty certificate providev with invoice/ bill etc. Complete in all repsect. | Job | 1 | 15000 | 15000 | |
| 45 | 22 | P/Fixing imported Door machine (New Star) Or Equivalent at floor base supporting Glass door of main enterance,Opertion Manager Chamber as per entire satisfaction of Regional Engineer/ Engineer Incharge. | No | 5 | 15000 | 75000 |
| 46 | 23 | P/F of hydraulic door closer best quality imported etc. Complete in all respect. | Each | 3 | 3000 | 9000 |
| 47 | 24 | Wooden Hanging Beam | ||||
| 48 | Semi cercal wooden hanging beam for glass partitions made with 1/2 “ thick in lassani top and oak ply paste and front back covered with lassani sheet frame made with partel wood as approved design and 03 coats of mate finish paint complete in all respect. | Rft | 25 | 500 | 12500 | |
| 49 | 25 | Logo / Theme Wall | ||||
| 50 | Logo wall at Reception made of chipboard with oak veneer pressed under 100 -150 kg/cm2 of air pressure and 60 C0 of temperature with softwood framing inside. Including complete joinery details. Complete in all respects as per drawing and specifications. Size (mm): W: 2590 x T: 75 x H: 2440 | Job | 1 | 40000 | 40000 | |
| 51 | 26 | BITUMEN STRONG ROOM | ||||
| 52 | Providing and Laying bitumen in a sold coat using in strong area with approved grade etc i/c repairing the walls using Ultra bond etc. as per entirer specification of Engineer Incharge. | Sft | 160 | 120 | 19200 | |
| 53 | 27 | Aluminum louver shutter | ||||
| 54 | P/Fixing Aluminum Louvers shutters below wash basin & sink with Aluminum frame 2mm thick 4" wide extruded section including fixing Aluminum louver shutter with handle, locks etc. complete in all respect as directed by the Engineer Incharge | Sft | 20 | 1700 | 34000 | |
| 55 | 28 | CONCRETE PAVER | ||||
| 56 | Providing and laying of pavers size 4"x8" having 3" thick best quality made of envicrete/ hub crete or equvilant with sand cusion approved colour over 2" thick p.c.c avg: and grouting in cement complete in all respect. | Sft | 600 | 290 | 174000 | |
| 57 | 29 | P/F of wooden wall paneling back side cash counter and staff sitting area made of MDF laminated tactile 4025 al noor, as per design approved design or as directed by Executive Engineer, MDF lassani sheet 1/2" thick imported quality having partal wooden frame base 2"x1-1/2 " covered with lamminated tactile sheet 5mm thick as per approved design. Complete in all respect. | Sft | 100 | 1100 | 110000 |
| 58 | 30 | WOODEN RAFTER | ||||
| 59 | i | Providing & fixing wooden rafter in 1/2'' thick lassani & laying oak wood ply / 16mm thick tactile alnoor MDF sheet 4'' x 6'' under lassani ceiling finished with matt finish paint with rafters finished with approved shade of lacquer polish best quality imported etc. complete in all respect. In Entrance lobby | Sft | 200 | 750 | 150000 |
| 60 | 31 | Stone Soling | ||||
| 61 | i | Providng and Laying Stone soling 6" thick including compaction, watering as in foundation complete in all respect | cft | 50 | 85 | 4250 |
| 62 | 32 | P/F imported glass frosted gliter paper at required places, job complete in all respects. (For Old Glass) | sft | 150 | 120 | 18000 |
| 63 | 33 | Removing, re-fixing and repairing of Aluminum windows including gas kit/ rubber packing, Locks, repalcement of broken glass with new as per existing design and shade etc. Complete in all respect. | Sft | 120 | 250 | 30000 |
| 64 | 34 | Providing SS planters of approved dia, size and standards job complete in all respects | No | 2 | 5200 | 10400 |
| 65 | 35 | Providing & fixing wooden rafters vertical posts up to ceiling in waiting area/ staff area, rafters made of MDF Tactile sheet 4025 alnoor made or in 1/2'' thick lassani box with partal wooden framing & laying oak wood ply size 4'' x 12'' with laying lacqure polish finish or rafters and back sheet made with laminated tactile sheet etc. complete in all respect. | Rft | 150 | 1200 | 180000 |
| 66 | 36 | Providing SS Trash bin of approved size and shape, complete in all respects | No | 5 | 3000 | 15000 |
| 67 | 37 | Supply and installation i/c transportation of standard strong room / locker room door of size 7’ x 4’ x 11”, the main frame should be of 9mm thickness angle or U-channel and 6mm thickness main shutter a composite of outer 6mm and inner 3mm. The space between outer and inner sheet should be filled with fire proof material, tale and alum crystals. The outer 6mm plate is reinforced with 3mm thick anti-torch material plate in the locking regions. The lock area should be protected with 1/8x27x30 inch copper sheet. Thickness of door slab is 2”. Locking box wall made of wide 4” M.S sheet plate covered with 3mm BS sheet two brass locks with triple control locking system. Hinges made from 2-1/2” dia solid steel bars 9” in length & 12” long 4” wide flat bars with all bearings. Locking system triple control 2 way locking system. Made of 2.5” x 2.5” x 6mm angle iron 2-1/2” long 1-1/2” steel shooting bolts fixed on it with total no 11 bolts 6 at front & 5 at rear. Grill door, main frame and 08 Nos. supporting strips should be of ½” M.S Plates with 6/8” solid rounds bars 13-14 at brass locks with master control keys operation with grill door i/c exact alignment, plumb, welding. Placement of strong room door in vertical position in the opening of the strong room with chain kopi and welding of the the angle bars with steel bars of the strong room bars | No | 1 | 600000 | 600000 |
| 68 | PLUMBING | |||||
| 69 | S.NO | DESCRIPTION/SPECIFICATION | UNIT | QTY | RATE | AMOUNT |
| 70 | SECTION-01, SUPPLY & INSTALLATION OF PLUMBING FIXTURES | |||||
| 71 | Supply and Installation of plumbing fixtures & faucets complete in all respects including all accessories, support, hangers, etc. ready to use as per specifications of Consultant. | |||||
| 72 | 1.1 | European style W.C. floor mounted type, with seat cover, flush tank, cover plate floor mounted brackets with fixing accessories. | ||||
| 73 | ii. | P/F ORISA type W.C Manufactured by Master / PORTA Ceramic or equivalent approved quality with integral tread 19’’ clear opening as measured between flushing rims, C.I. Trap 4’’ dia Gallons capacity low level flushing cistern of same manufacturers making good in cement concrete (1:2:4) complete. | Nos. | 1 | 25000 | 25000 |
| 74 | 1.5 | Wash basin hot and cold water mixer, etc. | ||||
| 75 | i. | Type - WB | Nos. | 1 | 8628 | 8628 |
| 76 | 1.6 | Stainless steel kitchen sink including stop cocks, P-trap / Bottle trap, waste pipe etc complete in all respects. | ||||
| 77 | i | SK - 1, 40" x 20" single bowl and single drainer. | Nos. | 1 | 22000 | 22000 |
| 78 | 1.8 | Toilet accessories complete set. | ||||
| 79 | i. | Soap Dispenser | Nos. | 1 | 2200 | 2200 |
| 80 | ii. | Towel Rod | Nos. | 1 | 3500 | 3500 |
| 81 | iii. | Paper Holder | Nos. | 1 | 1800 | 1800 |
| 82 | iv. | Coat Hooks | Nos. | 1 | 1300 | 1300 |
| 83 | vi. | P/F Looking Mirror best quality balgium made fixed with clips complete in all respect and size as per site requirement | Sft | 15 | 700 | 10500 |
| 84 | SECTION-02 WATER SUPPLY SYSTEM | |||||
| 85 | Supply, installation, testing and commissioning of complete pipe work for cold and hot water system including all accessories required to complete systems ready to operate as per specification, drawings & instruction of Consultant. | |||||
| 86 | 2.1 | Polypropylene Random PP-R pipes PN 20 and fittings with fusion jointing along with all types of unions, tees, bends, sockets, clamps hangers, supports, sleeves, masking plates,chiseling, making holes making good, excavation, bedding backfilling as required complete in all respect. | ||||
| 87 | ii. | Dia. OD 32 mm (also for A.C Drainage) | Rft | 100 | 280 | 28000 |
| 88 | SECTION-03 SOIL, WASTEVENT AND RAIN WATER DRAINAGE SYSTEM | |||||
| 89 | Supply, fixing, testing and commissioning of equipment, pipe work required to complete the soil, waste, vent and rain water systems in all respects with accessories ready to operate as per specifications, drawings instructions of Consultant. | |||||
| 90 | 3.1 | UPVC pipes of approved make along with specials, fittings bends wye, tees sockets , sleeves, masking plates, chiseling , making hole excavation, backfilling making good where as required jointing with rubber ring seal. | ||||
| 91 | i. | Dia 1-1/2" | Rft | 50 | 322 | 16100 |
| 92 | TOTAL | |||||
| 93 | WIRING WORKS | |||||
| 94 | ELECTRICAL WIRING | |||||
| 95 | Supply, laying, connection and testing of following wiring types; in heavy duty PVC Conduit recessed in walls, columns, slabs, floors or fixed at Ceiling above false ceiling or in Dura duct if exposed on walls, with all necessary fixing accessories, conduit/duct accessories, pull boxes, steel pull wires complete in all respects, required as per site conditions. with make/brand of material being specified in Annexure A. (PVC insulated Copper - 300/500 Volt Grade Wires to be used) | |||||
| 96 | (a) | Circuit Wiring (For Switchboard/Light Plug etc.) | ||||
| 97 | From DB to Switch Board or 2/3 pin Light Plug (5/10/13A) to be wired with 2x2.5 sq.mm S/C wires and 1 X 2.5 sq.mm S/C wire of Green/Yellow Colour as Circuit Protective Conductor (CPC) in 25 mm dia. heavy duty PVC conduit Each circuit shall have independent CPC. Maximum wiring of 2 light circuits can be pulled through 25 mm dia. PVC conduit. | Nos. | 5 | 4500 | 22500 | |
| 98 | (b) | Switch Board to Switch Board OR Switch Board to Light plug etc. Circuit Wiring | ||||
| 99 | Same as item No. A-1-1 (a) but from point to point i.e. Switchboard to Switchboard/Light Plug or Light Plug to Light Plug. (Side by Side or Back to Back Wiring points will not be payable and will be considered to be included in item No. A-1-1 (a) | Nos. | 5 | 1300 | 6500 | |
| 100 | ( c ) | Strong & Locker Rooms Wiring Circuit | ||||
| 101 | Same as item No A-1-1 (a) but including 40/.076 Cable with 20 A Switch Socket Outlet (SSO), back box etc. for connection to Switchboard in Strong & Locker Rooms complete with connections in all respects. | Nos. | 2 | 5200 | 10400 | |
| 102 | (a) | Point Wiring (Light/Fan etc.) | ||||
| 103 | From Switchboard to 1st Point (Light/Fan) with 1 x 1.5 sq.mm S/C wire from Piano Switch and 1 x 2.5 sq.mm wire common neutral including i/c P/F 10A Piano Switch in 20 mm dia. heavy duty PVC conduit, recessed in walls, columns, slabs, floors or fixed at Ceiling above false ceiling with all necessary fixing accessories, conduit accessories, 75 mm high PVC junction boxes, pull boxes, steel pull wires, connectors, M.S. sheet steel switch box 16 SWG with earth terminal with 2 coats of powder coating of orange colour, M.S. box shall be of the same size as that of 1, 2 or 3 upto 6 gangs flush type plate switches complete in all respects, required as per site conditions. (In case of point wiring at Ceiling, 2 X 1.5 sq.mm wires in Flexible Conduit from junction box equiped with PVC gland to light/fan fixture, will also have to be provided). Maximum wiring of 6 points (light/fan) can be pulled through 20 mm dia. PVC conduit. | Nos. | 25 | 1450 | 36250 | |
| 104 | (b) | Point to Point Wiring (Light/Fan etc.) | ||||
| 105 | Same as item No. A-1-2 (a) but from Point to Point and without including cost of Switch and M.S. sheet steel switch box 16 SW. (Maximum of 05 points can be connected with 1st Point) | Nos. | 8 | 700 | 5600 | |
| 106 | (a) | Wiring for Industrial Sockets for UPS Connections | ||||
| 107 | (i) | From UPS DB to Branch UPS I/O Connections (two connections) with 1 x 6.0 sq.mm 3 Core wire in 25 mm dia. heavy duty PVC conduit or PVC Dura duct (appropriate size), with all necessary fixing accessories, complete in all respects, required as per site conditions. | Rft. | 60 | 260 | 15600 |
| 108 | (ii) | From ATM DB/Branch UPS DB/Branch UPS to ATM UPS I/O Connections (two connections) with 1 x 4.0 sq.mm 3 Core PVC/PVC insulated wire in 20 mm dia. heavy duty PVC conduit or PVC Dura duct (appropriate size), with all necessary fixing accessories, complete in all respects, required as per site conditions. | Rft. | 60 | 160 | 9600 |
| 109 | (b) | Wiring from Main DB to UPS DB or any other purpose. | ||||
| 110 | Wiring with 1 x 6.0 sq.mm 3 Core PVC/PVC insulated wire in 25 mm dia. heavy duty PVC conduit or PVC Dura duct (appropriate size), with all necessary fixing accessories, complete in all respects, required as per site conditions. | Rft. | 25 | 260 | 6500 | |
| 111 | DATA / VOICE / TV WIRING | |||||
| 112 | Supply, laying, connection and testing of following wiring types; with make/brand of material being specified in Annexure A. | |||||
| 113 | (a) | Data points/outlets | ||||
| 114 | Wiring for each Data point from Communication Rack (Patch Panel) to each Data point on wall or in M.S floor outlet box with 4 pair Cat. 6E 23 AWG cable in 20 mm dia. heavy duty PVC conduit recessed in walls, columns, slabs, floors or above false ceiling with all necessary fixing accessories as required as per site condition, complete in all respects. | Nos. | 2 | 2500 | 5000 | |
| 115 | Main Telephone Cable | |||||
| 116 | Supply, installation and connection of 10 pair telephone cable to be connected from Utility MDF to Telephone Junction Box (TJB) in 25 mm dia PVC conduit including cost of identification tags, all necessary material / accessories complete in all respects.Actual length of cables to be installed shall be practically measured at site by the Contractor, duly checked by Engineer Incharge. | Rft. | 50 | 165 | 8250 | |
| 117 | MAIN / SUB MAIN CABLES | |||||
| 118 | FITTINGS, FIXTURES & ACCESSORIES | |||||
| 119 | Supply, Installation, testing and commissioning of following fittings/fixtures as per specified brand/make given in Annexure "A" recessed in or on wall / ceiling / column etc. complete in all respects, duly approved by Engineer Incharge prior to installaion. | |||||
| 120 | LIGHTS | |||||
| 121 | (The temperature / Colour Index to be got confirmed from Site Engineer before installation) | |||||
| 122 | (a) | Ceiling mounted LED Panel Light - 48W - 610 x 610 mm (Warm White/Warm/DayLight) recessed in False Ceiling | Nos. | 6 | 9500 | 57000 |
| 123 | (c ) | Ceiling mounted LED Down Light - 18/20W - 20 mm dia (Warm White/Warm/DayLight) recessed in False Ceiling | Nos. | 40 | 1700 | 68000 |
| 124 | FANS | |||||
| 125 | (a) | False Ceiling Fan 14/16 " sweep, Size(2'X2') | Nos. | 5 | 12100 | 60500 |
| 126 | POWER SOCKETS | |||||
| 127 | Switch Socket Outlet | |||||
| 128 | Following SSO complete with back box i.e. M.S. box, made of 16 SWG sheet steel with earth terminal having 2 coats of powder coating of orange colour, M.S. box shall be of the same size as that of SSO. | |||||
| 129 | (a) | 5 A - 2 Pin Round type SSO (for General Use) | Nos. | 2 | 690 | 1380 |
| 130 | ( c ) | 13A Duplex SSO - 3 Pin Flat type / Universal type (for UPS Power) | Nos. | 6 | 1500 | 9000 |
| 131 | Industrial Sockets | |||||
| 132 | Following Industrial Socket Unit (Male & Female Complete Set) complete with back box i.e. M.S. box, made of 16 SWG sheet steel with earth terminal having 2 coats of powder coating of orange colour. | |||||
| 133 | (a) | 16 A, 3 Pin | Nos. | 1 | 4000 | 4000 |
| 134 | CABLE CONTAINMENT | |||||
| 135 | DATA / VOICE FIXTURES | |||||
| 136 | Face Plates with I/Os | |||||
| 137 | Following Face Plates white/off white finish, complete with shuttered Click-ins, labels and all accessories including back box i.e. M.S. box, made of 16 SWG sheet steel having 2 coats of powder coating of orange colour. M.S. box shall be of the same size as that of Face Plate. | |||||
| 138 | (f) | Simplex Face Plate with RG-6 / RG-7 Connector for TV Cable | Nos. | 1 | 500 | 500 |
| 139 | Supply of Patch / Drop Cords | |||||
| 140 | Factory tested (imported) Cords of Cat6 - 23 AWG Cable of following sizes | |||||
| 141 | (a) | 01 meter Patch Cord | Nos. | 6 | 650 | 3900 |
| 142 | (b) | 03 meter Drop Cord | Nos. | 6 | 1300 | 7800 |
| 143 | Racks and Panels | |||||
| 144 | (a) | 19" Rack for Data Communication | ||||
| 145 | Supply and Installation of 19" - Communication Rack made of M.S Frame, Glass Door, Pull Handle, supported by perforated sides / M.S Cover of following size: | |||||
| 146 | 27U Floor Standing | Nos. | 1 | 35000 | 35000 | |
| 147 | (b) | Thermostatic type Exhaust/Cooling Fans | ||||
| 148 | Supply and Installation of Thermostatic type Exhaust/Cooling Fans in Communication Rack, with proper connections, complete in all respects | Nos. | 2 | 800 | 1600 | |
| 149 | INTERNAL COMPONENTS OF DBs | |||||
| 150 | Providing, installation, testing and commissioning of following Components as per brands/makes specified in Annexure "A" in already installed or to be installed DBs with proper connections and tagging, complete in all respects, as per Site requirements and prior approval of Bank's Engineer Incharge. | |||||
| 151 | Miniature Circuit Breakers (MCBs) Rail Type, C Type | |||||
| 152 | (a) | Single Pole (SP) - RC-6 KA | ||||
| 153 | (i) | 6/10 A | Nos. | 10 | 900 | 9000 |
| 154 | (ii) | 16/20/32 A | Nos. | 4 | 800 | 3200 |
| 155 | (b) | Double Pole (DP) - RC - 10 KA | ||||
| 156 | (i) | 16/32 A | Nos. | 1 | 4900 | 4900 |
| 157 | Change Over Switch 1-0-2 | |||||
| 158 | (ii) | 32 A | Nos. | 1 | 3700 | 3700 |
| 159 | BURGLAR ALARM SYSTEM | |||||
| 160 | WIRING | |||||
| 161 | Supply, laying, connection and testing of following wiring types; in already laid heavy duty PVC Conduit recessed in walls, columns, slabs, floors or fixed at Ceiling above false ceiling or in already laid Dura duct if exposed on walls, with all necessary fixing accessories, conduit/duct accessories, pull boxes, steel pull wires complete in all respects, required as per site conditions. with make/brand of material being specified in Annexure A. due in consultation with & recommendation of any one of Bank’s approved Security Company for different security sensing components, devices, sirens, smoke detector etc. complete with connections in all respect. | |||||
| 162 | (b) | 1 x 2 Pair Cable | Rft. | 120 | 15 | 1800 |
| 163 | EARTHING SYSTEM | |||||
| 164 | Supply, installation, testing and commissioning of Earthing / Grounding System including all material, boring, labor, tools, transportation, construction of appropriate sized Main Hole Pit (1' x 1' or 13" dia) with CI Cover, other accessories etc. Complete in all respects with detailed test report. TThe Earth Resistance should be below 05-OHM / Neutral to Ground potential less than 03V otherwise earthing would not be acceptable and neither payable. | |||||
| 165 | CHEMICAL TYPE | |||||
| 166 | Supply, installation, testing and commissioning of Chemical Enhanced Earthing System comprises of the following: | Job | 1 | 10584 | 10584 | |
| 167 | (a) | 1-1/2" dia - 10 ft Copper pipe filled with soil conditioning material/chemical with termination Clamps for Wire connections. | ||||
| 168 | (b) | 11 ft or more boring of 6" dia and placing above Copper pipe in it. | ||||
| 169 | ( c ) | Back filling of 6" dia boring with Chemical to enhance Conductivity. | ||||
| 170 | (d) | Fixing of 02 Nos. Copper Equipotential bars made with 150 mm wide, 50 mm high, 5 mm thick Earth Connecting Points (ECP) respectively with holes for fixing of Copper Conductor. | ||||
| 171 | ( e ) | Interconnection of ECP with termination Clamps of Chemical Pipe with 2 x 8 SWG Solid Copper Conductor or 2 x 10 sq.mm bare flexible Copper Conductor | ||||
| 172 | TOTAL | Rs | ||||
| GRAND TOTAL: | Rs 3,693,292.00 |
| MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION |
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: National Bank of Pakistan (Engineering), Sr. Vice President Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
The Supplier is:
The title of the subject procurement is: MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
National Bank of Pakistan (Engineering), Sr. Vice President
Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
+92-213-890-2590
teemar@nbp.com.pk
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
National Bank of Pakistan (Engineering), Sr. Vice President
Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
+92-213-890-2590
teemar@nbp.com.pk
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.10% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 0% of the contract price in acceptable form of Nil
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
Copies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount;
Manufacturer’s or Supplier’s Valid Warranty Certificate (if any);
Completion Certificate from Concerned Branch & Regional Office.
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P128299
To: National Bank of Pakistan (Engineering), Sr. Vice President Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between National Bank of Pakistan (Engineering), Sr. Vice President Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., MINOR RENOVATION WORK OF NBP AIB GHARO BRANCH (0187) HYDERABAD REGION, SINDH BALOCHISTAN REGION (P128299) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: National Bank of Pakistan (Engineering), Sr. Vice President Office of the Department Head-Tender, Procurement Division-LCMG, 3rd Floor, NBP Head Office Building, I.I Chundrigar Road, Karachi
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}
| Experience under construction contracts in the role of prime contractor for at least the last 03 years, starting from 1st May 2023 |
| Three ( 03) number of similar contracts that have been satisfactorily completed as a prime contractor during last 03 years of atleast Three 3.0 (M) |
| Non-performance of a contract did not occur as a result of contractor default since [ 3 years]. Bidder’s financial position and prospective long term profitability sound according to criteria established in 3.1 below and assuming that all pending litigation will be resolved against the Bidder No consistent history of court/arbitral award decisions against the Bidder since 1st May [2023] |
| Bidder Must Provide copies of Work Orders & Agreement of ongoing projects & current status certificate from awarding authority. |
| (i) The Bidder shall demonstrate that it has access to, or has available, liquid assets, unencumbered real assets, lines of credit, and other financial means (independent of any contractual advance payment) sufficient to meet the construction cash flow requirements estimated as PKR 2.0 (M)for the subject contract(s) net of the Bidders other commitments | (ii) The Bidders shall also demonstrate, to the satisfaction of the Procuring agency/Employer, that it has adequate sources of finance to meet the cash flow requirements on works currently in progress and for future contract commitments. | (iii) The audited balance sheets or, if not required by the laws of the Bidder’s country, other financial statements acceptable to the Procuring agency/Employer for the last 03 years shall be submitted and must demonstrate the current soundness of the Bidder’s financial position and indicate its prospective long-term profitability. |
| Minimum average annual construction turnover of PKR 08 Million, calculated as total certified payments received for contracts in progress and/or completed within the last 03years, divided by 03 years, starting from1st May 2023 |