In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil
Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
+92-309-799-3589
afaqmalik3589@gmail.com
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)) The subject of procurement is: REHABILITATION OF ADMIN BLOCK AT NAWABSHAH AIRPORT Expected commencement date: Monday, December 28, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P130483 |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Tuesday, October 20, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid:
|
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 120 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Banker's Cheque, Call at Deposit |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province). Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Tuesday, October 27, 2026 11:00 AM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Tuesday Date: October 27, 2026 Time : 11:30 AM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 5.00%. The Performance Guarantee shall be acceptable in the form of: Pay Order, Banker's Cheque, Call at Deposit, Bank Guarantee, Demand Draft |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Any | NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) PEC |
| Eligibility Criteria | Document |
|---|---|
| Affidavit for Non-Blacklisting and Non-Litigation | Yes |
| Licensed Constructors registered with PEC in Category C-6 or above | Yes |
Least Cost Based Selection (LCBS)
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| Civil & Electrical Works | Address: Nawabshah Airport Schedule: 120 Days Quantity: 01/job |
1/job | 200000 PKR |
No
Jobs Without Lots :
Job: Civil & Electrical Works
Specifications / Requirements:
| Sr. No | Ref. No. | Description | Unit | Qty | Rate | Rate in Words | Amount |
|---|---|---|---|---|---|---|---|
| 1 | BW-01 | DISMANTLING BURNT BRICK MASONRY IN LIME OR CEMENT MORTAR FOUNDATION, BASEMENT, PLINTH AND GROUND FLOOR INCLUDING STACKING SALVAGED MATERIAL (SERVICEABLE) AND DISPOSING OF SURPLUS MATERIAL AS DIRECTED WITHIN THREE UNIT CHAINS (91.5 M). | %Cft | 24 | |||
| 2 | BW-02 | TAKING OUT CAREFULLY SHUTTERS OF DOORS AND WINDOWS IN GROUND FLOOR AND STACKING AS DIRECTED WITHIN THREE CHAINS (91.5 M). | Nos. | 2 | |||
| 3 | BW-03 | LEVELLING AND DRESSING THE GROUND BY CUTTING AND FILLING EARTH UPTO 6 INCHES (152 MM) IN DEPTH INCLUDING CONSOLIDATING AND WATERING, COMPLETE AS REQUIRED. | %Sft | 1350 | |||
| 4 | BW-04 | EXCAVATION FOR FOUNDATION TRENCHES AND DRAINS IN ALL KINDS OF SOIL (EXCEPT GRAVELLY AND MURUM SOIL, WET SILT, CLAY OR MUD CONGLOMERATION OF GRAVEL AND BOULDERS, SOFT, SANDY OR DISINTEGRATED SANDY AND HARD ROCK) AND BACK FILLING THE EXCAVATED MATERIAL IN FOUNDATION, PLINTH OR UNDER FLOOR INCLUDING BREAKING CLODS, WATERING, CONSOLIDATION BY RAMMING IN LAYERS NOT EXCEEDING 9 INCHES (229 MM) IN DEPTH TO FULL COMPACTION, DRESSING AND DISPOSAL OF SURPLUS EXCAVATED STUFF AS DIRECTED, LEAD UPTO ONE CHAIN (30.5 R.M) AND LIFT UPTO 5 FEET (1.52 M). | %Cft | 480 | |||
| 5 | BW-05 | PROVIDING AND LAYING 1:4:8 (1 CEMENT 4 SAND AND 8 COARSE AGGREGATE) CEMENT CONCRETE USING GRADED STONE BALLAST 2 INCHES (51 MM) AND DOWN GAUGE IN FOUNDATION INCLUDING LEVELLING, COMPACTING AND CURING ETC. COMPLETE. | %Cft | 353 | |||
| 6 | BW-06 | PROVIDING AND LAYING 1:4:8 CEMENT CONCRETE BED UNDER FLOORS USING GRADED STONE BALLAST 1 INCHES (25 MM) AND DOWN GAUGE WITH LEVELLING AND RAMMING, WATERING AND CURING ETC. COMPLETE.. | %Cft | 947 | |||
| 7 | BW-07 | PROVIDING AND CARRYING OUT TERMITE PROOFING IN FOUNDATIONS, UNDER FLOORS AND WOOD WORK SURFACE WITH A SOLUTION USING OF CONFRONT TC WITH WATER AND SPRAYING THE SOLUTION OF THE AREA TO BE TREATED AS COMPLETED AS PER DIRECTION OF ENGINEER INCHARGE. | Sft | 416 | |||
| 8 | BW-08 | PROVIDING AND LAYING REINFORCED CEMENT CONCRETE USING CRUSHED GRADED BOULDERS 3/4 INCH (19 MM) AND DOWN GAUGE HAVING A MINIMUM WORKS CUBE CRUSHING STRENGTH OF 3000 IBS. PER SQ INCH (20.69 N/MM2 ) AT 28 DAYS WITH A MIX NOT LEANER THAN 1:2:4 IN COLUMN FOOTING OF REQUIRED SHAPE INCLUDING FORM WORK AND ITS REMOVAL, COMPACTING AND CURING ETC. COMPLETE BUT EXCLUDING THE COST OF REINFORCEMENT, IN FOUNDATION BASEMENT AND PLINTH | %Cft | 42 | |||
| 9 | BW-09 | PROVIDING AND LAYING REINFORCED CEMENT CONCRETE USING CRUSHED GRADED BOULDERS 3/4 INCH (19 MM) AND DOWN GAUGE HAVING A MINIMUM WORKS CUBE CRUSHING STRENGTH OF 3000 IBS.. PER SQ INCH (20.69 N/MM2) AT 28 DAYS WITH A MIX NOT LEANER THAN 1:2:4 IN PLINTH BEAMS OF REQUIRED SHAPE AND DESIGN INCLUDING FORM WORK AND ITS REMOVAL, COMPACTING AND CURING ETC. BUT EXCLUDING THE COST OF REINFORCEMENT, TN FOUNDATION BASEMENT AND PLINTH | %Cft | 16 | |||
| 10 | BW-10 | PROVIDING AND LAYING REINFORCED CEMENT CONCRETE USING CRUSHED GRADED BOULDERS 3/4 INCH (19 MM) AND DOWN GAUGE HAVING A MINIMUM WORKS CUBE CRUSHING STRENGTH OF3000 IBS. PER SQ INCH (20.69 N/MM2) AT 28 DAYS WITH A MIX NOT LEANER THAN 1:2:4 IN STRAIGHT BEAMS, LINTELS CANTILEVER BEAMS OF REQUIRED SHAPE OR SECTION INCLUDING FORM WORK AND ITS REMOVAL, COMPACTING AND CURING ETC. COMPLETE BUT EXCLUDING THE COST OF REINFORCEMENT, IN BASEMENT AND GROUND FLOOR. | %Cft | 22 | |||
| 11 | BW-11 | PROVIDING AND LAYING REINFORCED CEMENT CONCRETE USING CRUSHED GRADED BOULDERS 3/4 INCH (19 MM) AND DOWN GAUGE HAVING A MINIMUM WORKS CUBE CRUSHING STRENGTH OF 3000 IBS. PER SQ INCH (20.69 N/MM2) AT 28 DAYS WITH A MIX NOT LEANER THAN 1:2:4 IN ORDINARY SLAB 5 INCHES (127 MM) TO 6 INCHES (152 MM) THICK INCLUDING FORM WORK AND ITS REMOVAL COMPACTING AND CURING ETC. COMPLETE BUT EXCLUDING THE COST OF REINFORCEMENT, IN BASEMENT PLINTH AND GROUND FLOOR. | %Cft | 46 | |||
| 12 | BW-12 | PROVIDING AND LAYING COLD WORKED TWISTED RIBBED STEEL REINFORCEMENT BARS WITH MINIMUM YIELD STRESS OF 60,000 PSI WITH AND INCLUDING THE COST OF STRAIGHTENING, CUTTING, BENDING, BINDING, WASTAGE, COMPLETE IN ALL KINDS OF RCC WORK. | Kg | 458 | |||
| 13 | BW-13 | PROVIDING AND LAYING FLOORS OF 2 INCHES (51 MM) THICK 1:2:4 CEMENT CONCRETE USING GRADED SCREENED BAJRI 3/4 INCH (19 MM) AND DOWN GAUGE IN GROUND FLOOR LAID IN PANELS INCLUDING FORM WORK, CONSOLIDATION, FINISHING, AND CURING ETC. COMPLETE. | %Sft | 1664 | |||
| 14 | BW-14 | PROVIDING AND LAYING FIRST CLASS SOLID BURNT BRICK MASONRY SET IN CEMENT MORTAR 1:6 IN STRAIGHT OR CURVED WALLS MORE THAN 13-1/2 INCHES (343 MM) THICK INCLUDING SCAFFOLDING, RAKING OUT JOINTS AND CURING ETC. COMPLETE IN FOUNDATION, BASEMENT AND PLINTH (FOUNDATION AND BASEMENT MASONRY UPTO 5 FEET (1.52 RU.M.) DEPTH AND PLINTH UPTO 4 FEET (1.2 RU.M.) HEIGHT FROM GROUND LEVEL) . | %Cft | 192 | |||
| 15 | BW-15 | PROVIDING AND LAYING FIRST CLASS SOLID BURNT BRICK MASONRY SET IN CEMENT MORTAR 1:6 IN STRAIGHT OR CURVED WALLS 9 TO 13-1/2 INCHES (229 MM TO 343 MM) THICK INCLUDING SCAFFOLDING, RAKING, OUT JOINTS AND CURING ETC. COMPLETE IN GROUND FLOOR SUPERSTRUCTURE . | %Cft | 281 | |||
| 16 | BW-16 | PROVIDING AND LAYING 1:9 CEMENT CONCRETE USING SCREENED GRADED BAJRI 3/4 INCH (19 MM) AND DOWN GAUGE IN TERRACING 3 INCHES (76 MM) AVERAGE THICKNESS TO REQUIRED SLOPE IN PANELS INCLUDING FORM WORK, CONSOLIDATION, FINISHING, CURING ETC. AND PAINTING THE SURFACE WITH PLASTIC BITUMEN NO. 4 AT THE RATE OF 15 IBS PER HUNDRED SQUARE FEET (0.73 KG PER S.M) BLINDED WITH SAND AT THE RATE OF 2 CUBIC FEET PER HUNDRED SQUARE FEET (0.06 KG PER S.M) COMPLETE" ON GROUND FLOOR ROOF. | %Sft | 100 | |||
| 17 | BW-17 | 1/4" (6.4 MM) THICK CEMENT PLASTER 1:4 ON SOFFITS OF CEILING, CANTILEVER SLABS, SIDES AND SOFFITS OF BEAMS ETC., IN BASEMENT, MEZZANINE AND GROUND FLOOR INCLUDING MAKING EDGES, CORNERS AND CURING ETC., COMPLETE. | %Sft | 100 | |||
| 18 | BW-18 | 3/4'' (19 MM) THICK CEMENT PLASTER 1:4 ON WALLS AND COLUMNS ETC. IN BASEMENT, PLINTH, MEZZANINE AND GROUND FLOOR INCLUDING MAKING EDGES, CORNERS, AND CURING ETC., COMPLETE. | %Sft | 808 | |||
| 19 | BW-19 | PROVIDNG AND FIXING FIBER SHED CONSISTING OF 5 PLY FIBER SHEET AND 2" X 2'' M.S BOX PIPE 16 GAUGE MAIN FRAME BEAMS AND CENTRAL BRACING 2" X 2" AT 24" C/C DIAGONAL AND 2"X2" SUPPORT UPTO 2 FEET C/C OVER 4" DIA M.S PIPE 16 GAUGE 10-14 FEET HEIGH I/C THE COST OF EXCAVATION WITH PCC 1 :2:4 AND RCC WITH STEEL AND M.S STEEL PLATE 1 /2" THICK IN FOUNDATION, SIZE 2'X2' CUTTING FITTING, WELDING PAINTING ETC, COMPLETE AS PER DIRECTION OF ENGINEER IN-CHARGE | Sft | 800 | |||
| 20 | BW-20 | PROVIDING AND FIXING IRON GRILLS WITH REQUIRED SECTION OF ANGLE / FLAT IRON AND M.S SQUARE BAR AS PER APPROVED DESIGN INCLUDING WELDING ALL SIDES OF THE SECTION AT THE JUNCTION, AND FIXING WITH SUNK IRON SCREWS, PAINTING TWO COATS OF RED OXIDE PAINT ETC. COMPLETE AS REQUIRED IN ANY FLOOR IN MASONRY OR CONCRETE WORK. | Kg | 912 | |||
| 21 | BW-21 | PROVIDING AND LAYING IN FLOOR C.C. 1:2:4 TUFF PAVER 2-1/2" THICK (AVG. STRENGTH 7000 PSI) OF APPROVED DESIGN AND COLOUR PATTREN LAID ON SAND CUSHION FILLING OF JOINT WITH SAND AND WATEING ETC. COMPLETE AS PER DIRECTION OF ENGINEER LNCHARGE. (THE COST OF SAND CUSHION IS INCLUDED). | Sft | 5356 | |||
| 22 | BW-22 | PROVIDING AND FIXING KITCHEN CABINET FLOOR 3/4 THICK LAMINATED BOARD WITH BEST QUALITY DEODAR WOOD FRAME AND BEADING 1/8" THICK HARD BOARD BANKING REQUIRED SECTION IN APPROVED PATTERN ETC,, FIXED WITH RAWAL PLUGS SCREWS I/C COST OF GLUE, NAIL, HINGES, HANDLES ETC AS PER DRWAING, COMPLETED IN ALL RESPECT. | Sft | 16 | |||
| 23 | BW-23 | PROVIDING AND FIXING KITCHEN WALL CABINET MAKING OF SHUTTER BOARD BOX & 3/4 INCH THICK HIGH GLOSS LAMINATED LASANI SHUTTER, PVC BEADING PVC BEADING, DEODAR WOODEN FRAM 2.5 X 1.25 INCH SIZE MAKING TRAY DRAWER OF APPROVED DESIGN ETC, FIXED WITH RAWAL PLUGS SCREWS INCLUDING COST OF GLUE, NAIL, HINGES, HADLES ETC AS PER DRAWINGS, COMPLETE IN AL RESPECT. | Sft | 8 | |||
| 24 | BW-24 | PROVIDING AND FIXING WITH BRASS SCREWS OR SPECIALTY SUPPLIED SCREWS HYDRAULIC DOOR CLOSER RAYOBI OF APPROVED DESIGN NO. 62, JAPAN MAKE, CUTTING WOOD ETC., TO REQUIRED SHAPE AND SIZE AS PER DIRECTION OF ENGINEER-IN-CHARGE. | Nos. | 2 | |||
| 25 | BW-25 | PROVIDING AND FIXING WITH BRASS SCREWS ALPHA KNOB SET LOCK OF APPROVED DESIGN (NO. 7000) JAPAN MAKE, CUTTING WOOD TO REQUIRED SHAPE AND SIZE WITH TWO OPERATING KEYS AS PER DIRECTION OF THE ENGINEER-IN-CHARGE | Nos. | 3 | |||
| 26 | BW-26 | REPLACING G.I. WIRE GAUZE OF 22 GAUGE AND 144 MESH PER SQ.INCH INCLUDING REPLACING THE BEADING WHERE NECESSARY WITH BEST QUALITY DEODAR WOOD OF EXISTING DESIGN AND SECTION WITH IRON SCREW INCLUDING DISMANTLING WIRE GAUZE ETC. AND REMOVAL OF RUBBISH AS REQUIRED . | Sft | 105 | |||
| 27 | BW-27 | PROVIDING AND FIXING WITH BRASS SCREWS CARONA BATH LATCH LOCK OF APPROVED DESIGN (NO. 21031), (JAPAN MAKE), CUTTING WOOD TO REQUIRED SIZE AND SHAPE WITH TWO OPERATING KEYS AS PER DIRECTION OF THE ENGINEER-IN-CHARGE. | Nos. | 3 | |||
| 28 | BW-28 | PROVIDING AND FIXING APPROVED BRASS DRAWER AND CUPBOARD LOCK WITH BRASS SCREWS INCLUDING TWO OPERATING KEYS: 2-3/4" (70 MM) SIZE (4 LEVERS) | Nos. | 4 | |||
| 29 | BW-29 | PROVIDING AND FIXING ALUMINIUM SHEET OF 22 GAUGE (1.15 MM THICK) ON WOODEN SURFACE WITH SUNKEN ALUMINIUM SCREW OF REQUIRED SIZE AS PER DIRECTION OF THE ENGINEER-IN-CHARGE. | Sft | 30 | |||
| 30 | BW-30 | PROVIDING AND FIXING FULLY GLAZED CHAMPAGNE ANODIZED ALUMINIUM SLIDING WINDOWS AS PER BRITISH STANDARD MANUFACTURED BY LUCKY, PRIME, CHAWLA, KRUDSON, PAKISTAN CABLE AND ALCOP (FIXING THROUGH THEIR APPROVED FABRICATORS), DELUXE MODEL BOX SECTION 95MM X 30MM AND 1.6MM THICK INCLUDING THE COST OF ALUMINIUM NETTING ,FITTINGS, WITH ALL ACCESSORIES CUTTING HOLE ETC. AND MAKING GOOD DAMAGES TO WALLS ETC. COMPLETE AS REQUIRED IN ANY FLOOR AS PER DIRECTION OF ENGINEER-IN-CHARGE, BUT EXCLUDING THE COST OF GLASS PANS. | Sft | 24 | |||
| 31 | BW-31 | PROVIDING AND FIXING FULLY GLAZED CHAMPAGNE ANODIZED ALUMINIUM SWING DOOR WITH FRAME AS PER BRITISH STANDARD MANUFACTURED BY LUCKY, PRIME, CHAWLA, KRUDSON, PAKISTAN CABLE AND ALCOP (FIXING THROUGH THEIR APPROVED FABROCATORS), DELUXE MODEL SECTION, 101.6MM X 44.5MM AND 1.6MM THICK INCLUDING THE ALUMINIUM FITTINGS, WITH ALL ACCESSORIES CUTTING HOLE ETC. AND MAKING GOOD DAMAGES TO WALLS ETC. COMPLETE AS REQUIRED IN ANY FLOOR AS PER DIRECTION OF ENGINEER-IN-CHARGE, BUT EXCLUDING THE COST OF GLASS PANS. | Sft | 56 | |||
| 32 | BW-32 | PROVIDING AND FIXING FULLY GLAZED CHAMPAGNE ANODIZED ALUMINIUM FIXED WINDOWS PARTITION AS PER BRITISH STANDARD MANUFACTURED BY LUCKY, PRIME, CHAWLA, KRUDSON, PAKISTAN CABLE AND ALCOP (FIXING THROUGH APPROVED FABRICATORS) DELUXE MODEL BOX SECTION 101.76MM X 44.50MM AND 1.6MM THICK INCLUDING THE COST OF ALUMINIUM FITTINGS, WITH ALL ACCESSORIES CUTTING HOLE ETC. AND MAKING GOOD DAMAGES TO WALLS ETC. COMPLETE AS REQUIRED IN ANY FLOOR AS PER DIRECTION OF ENGINEER-IN-CHARGE, BUT EXCLUDING THE COST OF GLASS PANS. | Sft | 184 | |||
| 33 | BW-33 | PROVIDING AND FIXING TINTED GLASS PANES 5MM THICK TO M.S. BOX PIPE / ALUMINIUM DOOR, WINDOWS AND VENTILATORS INCLUDING THE COST OF LABOUR BUT EXCLUDING THE COST OF M.S. SQUARE PIPE BEADING, RUBBER PACKING AND SCREW IN ANY FLOOR AT ANY HEIGHT. | Sft | 264 | |||
| 34 | BW-34 | PROVIDING AND FIXING PVC HARD SHEET WALL PANELLING OR LINING (PRINTED) ON WALL, JAMBS, SKIRTING ETC., ON WOODEN BACKING BUT EXCLUDING THE COST OF BACKING ETC., AS REQUIRED. | Sft | 706 | |||
| 35 | BW-35 | PROVIDING AND LAYING FLOOR OF 6MM (APPROX: 1/4") THICK COLOURED GLAZED TILES 12" X 12" (304MM X 304MM) OF MASTER MAKE (PAKISTANI) FIRST GRADE IN GROUND FLOOR LAID OVER 1" (25MM) THICK CEMENT MORTAR 1:2 (1 CEMENT AND 2 SAND) INCLUDING JOINTING AND WASHING THE TILES WITH WHITE CEMENT SLURRY A MATCHING COLOUR (BY USING PIGMENT IN WHITE CEMENT) AND CURING ETC. COMPLETE. | %Sft | 64 | |||
| 36 | BW-36 | PROVIDING AND FIXING 1/4"(6MM APPROX.) THICK OF PAKISTANI MAKE FIRST GRADE COLOURED GLAZED TILES UPTO 144 SQ.IN SIZE IN DADO AND SKIRTING IN GROUND FLOOR OVER 1/2" (13MM) THICK BASE OF CEMENT MORTAR 1:3 SETTING OF TILES IN SLURRY OF GREY CEMENT OVER MORTAR BASE INCLUDING FILLING THE JOINT WITH WHITE CEMENT SLURRY TO MATCHING THE COLOUR AND WASHING THE TILE, CURING AND CLEANING ETC. COMPLETE | %Sft | 112 | |||
| 37 | BW-37 | PROVIDING AND LAYING FLOOR OF 1 INCH (19 MM) THICK GRANITE STONE PAKISTANI ORIGIN TILES MORE THAN 7 SQ.FT. UPTO 16 SQ.FT. (MORE THAN 0.65 SQ.M UPTO 1.48 SQ.M) SIZE FINE DRESSED ON THE SURFACE, WITHOUT WINDING IN GROUND FLOOR OVER 1 INCH (25 MM) CEMENT MORTAR 1:2 (ONE CEMENT TWO SAND) SETTING THE MARBLE TILES WITH GREY CEMENT SLURRY OVER LIME MORTAR, JOINTING AND WASHING THE TILES WITH WHITE CEMENT SLURRY INCLUDING CURING, RUBBING AND POLISHING ETC. COMPLETE, INCLUDING THE COST OF MORTAR. | %Sft | 16 | |||
| 38 | BW-38 | DISTEMPERING WITH VINYLE DISTEMPER (ICI) DULUX PAINTEX OF APPROVED MAKE AND SHADE IN TWO COATS OVER AND INCLUDING THE COST OF ONE PRIMING COAT OF LIME WASH INCLUDING SAND PAPERING, DUSTING, AND FILLING THE HOLES, CRACKS AND INEQUALITIES, IF ANY, AT ANY HEIGHT IN ANY FLOOR. | %Sft | 762 | |||
| 39 | BW-39 | DISTEMPERING THREE RENEWAL COATS WITH VINYLE DISTEMPER (PAINTEX ICI DULUX) OF APPROVED MAKE AND SHADE TO WALLS AND CEILING ETC., INCLUDING SCRAPING CLEANING THE OLD SURFACE IN ANY FLOOR . | %Sft | 1087 | |||
| 40 | BW-40 | REPAINTING TWO COATS WITH PLASTIC EMULSION PAINT OF (!CL) DULUX MAKE AND SHADE TO WALLS AND CEILING INCLUDING CLEANING, AND SAND PAPERING THE SURFACE AS DIRECTED BY THE ENGINEER-IN-CHARGE IN ANY FLOOR. | %Sft | 3531 | |||
| 41 | BW-41 | REPAINTING TWO COATS WITH ENAMEL PAINT OF APPROVED MAKE AND SHADE TO PLASTERED SURFACE ETC., INCLUDING SAND PAPERING THE SURFACE AS DIRECTED BY THE ENGINEER-IN-CHARGE IN ANY FLOOR. | %Sft | 651 | |||
| 42 | BW-42 | PAINTING PLASTERED SURFACE WITH SUPER GLASS SYNTHETIC ENAMEL PAINT OF APPROVED MAKE AND SHADE TWO COATS OVER AND INCLUDING THE COST OF ONE COAT OF PRIMING COMPLETE AT ANY HEIGHT IN ANY FLOOR | %Sft | 356 | |||
| 43 | BW-43 | REPAINTING TWO COATS WITH ENAMEL PAINT (ROBIALAC) OF APPROVED MAKE AND SHADE TO WOOD WORK INCLUDING CLEANING AND SAND PAPERING THE SURFACE AS DIRECTED BY THE ENGINEER-IN-CHARGE IN ANY FLOOR. | %Sft | 519 | |||
| 44 | BW-44 | PAINTING IRON WORK WITH ENAMEL PAINT OF APPROVED MAKE AND SHADE TWO COATS OVER AND INCLUDING THE COST OF ONE COAT OF PRIMING COMPLETE AT ANY HEIGHT IN ANY FLOOR. | %Sft | 418 | |||
| 45 | BW-45 | REPAINTING TWO COATS WITH ENAMEL PAINT (ROBIALAC) OF APPROVED MAKE AND SHADE TO IRON WORK INCLUDING SCRAPING AND SAND PAPERING THE SURFACE AS DIRECTED BY THE ENGINEER-IN-CHARGE IN ANY FLOOR. | %Sft | 292 | |||
| 46 | BW-46 | P/F WINDOWS ROLL UP BLINDS SUNSCREEN, DARK OUT, OR TRANSLUCENT FABRIC ANY COLOUR/SHADE BEST QUALITY (IMPORTED) WITH MANUAL ROLL UP ARRANGEMENTS COMPLETE IN ALL RESPECT WITH ALL OTHER REQUIRED ACCESSORIES AND HARDWARE FROM THE APPROVED SUPPLIERS AND MANUFACTURERS, AS PER DIRECTION OF ENGINEER INCHARGE | Sft | 297 | |||
| 47 | BW-47 | PROVIDING AND 'FIXING 2" DIA STAINLESS STEEL PIPE (18 GAUGE) RAILING ALONGWITH 4 NOS 3/4" DIA PARALLEL PIPE HAVING S/S PIPE VERTICAL POST 2" DIA AT 3 FT C/C AVERAGE SPACING AND 4" DIA VERTICAL POST AT START TURNING AND END POINT INCLUDING COST OF LABOUR, WELDING CHARGES FITTING & FIXING IN MARBLE FLOOR AND WALL ETC COMPLETE AS PER DIRECTION OF THE ENGINEER INCHARGE. | Rft | 12 | |||
| 48 | BW-48 | REPAINTING TWO COATS WITH WEATHER SHIELD PAINT OF (ICI) DULUX MAKE AND SHADE ON PLASTER SURFACE (EXTERNAL) INCLUDING CLEANING, SAND PAPERING THE SURFACE AS DIRECTED BY THE ENGINEER-IN-CHARGE IN ANY FLOOR. | %Sft | 3147 | |||
| 49 | S&PW-01 | PROVIDING AND FIXING 1/2 INCH (15 MM) DIA CP BIB COCKS. | Nos. | 2 | |||
| 50 | S&PW-02 | PROVIDING AND FIXING 1/2 INCH (15 MM) DIA CP STOP COCKS. | Nos. | 6 | |||
| 51 | S&PW-03 | PROVIDING & FIXING CHROMIUM PLATED MUSLIM BIB-COCK WITH MUSLIM SHOWER OF APPROVED QUALITY. | No | 1 | |||
| 52 | S&PW-04 | PROVIDING AND FIXING 3/4 INCHES (19 MM) DIA FULL WAY GUN METAL VALVES WITH WHEELS THREADED OR FLANGED ENDS WITH RUBBER WASHERS, (STANDARD PATTERN).. | No | 1 | |||
| 53 | S&PW-05 | PROVIDING AND FIXING UPVC MULTI FLOOR TRAPE OF SIZES WITH GRATINGS INCLUDING CUTTING AND MAKEING THE REQUSITE NUMBER OF HOLES IN WALLS PLINTH AND FLOORS AND MAKING GOOD IN 1:2:4, C.C. | Nos. | 4 | |||
| 54 | S&PW-06 | PROVIDING AND FIXING APPROVED QUALITY STAINLESS STEEL SINK 48” X 20” PAK MADE (ATLAS) COMPLETE WITH BRASS OXIDIZED BOLT KIT/ANGLE IRON BRACKETS BUILT INTO WALLS ½” DIA CP SINK MIXER 1-1/4” RUBBER PLUG AND CP BRASS CHAIN 1-1/4” CP BRASS WASTE 1-1/4” DIA MALLEABLE IRON OR CP BRASS BOTTLE TRAP WITH MALLEABLE IRON OR BRASS UNIONS AND MAKING REQUISITE NUMBER OF HOLES IN WALLS, PLINTH AND FLOOR FOR PIPE CONNECTIONS AND MAKING GOOD IN CEMENT CONCRETE 1:2:4 | No | 1 | |||
| 55 | S&PW-07 | PROVIDING AND FIXING 20MM DIA PPRC PIPE PN-20 WITH SPECIALS AND CLAMPS ETC INCLUDING CUTTINGAND FITTING COMPLETE WITH AND IN-CLUDING THE COST OF BREAKING THROUGH WALLS AND ROOF AND MAKING GOOD ETC; AFTER CLEANING THE PIPE AND CARTAGE WITHIN 10 MILES | Rft | 50 | |||
| 56 | S&PW-08 | PROVIDING AND FIXING 3 INCHES (80 MM) DIA UN PLATISIZED POLYVINYL CHLORIDE PIPE (U.P.V.C) "D" CLASS AND SPECIALS ETC. INCLUDING CUTTING AND FITTING COMPLETE WITH AND INCLUDING THE COST OF CUTTING TRENCH UPTO 1-1/2 FEET DEEP REFILLING, WATERING, RAMMING, AND DISPOSAL OF SURPLUS EARTH WITHIN ONE CHAIN AND AFTER CLEANING THE PIPE AND CARTAGE WITHIN 10 MILES (16.09 KM.) (WORKING PRESSURE 12 KG/CM2) PIPE. | Rft | 30 | |||
| 57 | S&PW-09 | PROVIDING AND FIXING 6" X 6" (150 MM X 150 MM) WITH 4 INCHES (100 MM) OUTLET CEMENT CONCRETE C.I. GULLY TRAP WT: 42 IBS. (19 KG.) COMPLETE WITH 4 INCHES THICK (100 MM) 1:2:4 CEMENT CONCRETE FOR BED AND KERB, 1/2 INCH (13 MM) THICK CEMENT PLASTER (1:3) TO THE KERB, C.I. GRATING 6 INCHES X 6 INCHES (150 MM X 150 MM) AND C.I. COVER AND FRAME 12 INCHES X 12 INCHES (305 MM X 305 MM) (INSIDE) ETC., COMPLETE... | No | 1 | |||
| 58 | S&PW-10 | DO. DO. RCC COVER (12" X 12") (305MM X 305MM) THICK WITH HANDLE. | No | 1 | |||
| 59 | S&PW-11 | PROVIDING MANHOLE TYPE 'B' SIZE 3 FEET X 2-1/2 FEET OR 914 MM X 762 MM (INSIDE DIMENSIONS) X 4 FEET (1219 MM DEEP AS PER APPROVED DESIGN AND SPECIFICATIONS COMPLETE FOR 4 INCHES TO 12 INCHES (100 MM TO 305 MM) DIA. PIPE 4 FEET TO 7 FEET-5 INCHES (1.22 M TO 2.26M) DEPTH WITH 18 INCHES (457 MM) DIA. (INSIDE) CAST IRON COVER AND FRAME (WEIGHTS 1 CWT. 3 QRS.) OR 88.9 KG, FIXED IN R.C.C.1:2:4 SLAB 6 INCHES (152 MM) THICK, 9 INCHES (229 MM) THICK BURNT BRICK MASONRY WALLS SET IN 1:4 C.M., 6 INCHES (152 MM) THICK 1:3:6 C,C. IN FOUNDATION, 1:2:4 C.C. IN BENCHING AND 1/2 INCH (13 MM) THICK CEMENT PLASTER IN 1:3 C.M., TO ALL INSIDE WALL SURFACES, CHANNELS AND BENCHING ETC. AND TO TOP INCLUDING PROVIDING AND FIXING CAST IRON FOOT REST AT EVERY FOOT OF DEPTH AND MAKING REQUISITE NUMBER OF MAIN AND BRANCH CHANNELS BUT EXCLUDING THE COST OF EXCAVATION, BACK FILLING, DISPOSAL OF EXCAVATED STUFF, MANHOLE COVER AND FRAME. | No | 1 | |||
| 60 | S&PW-12 | PROVIDING & FIXING C.I COVER & FRAME 24" DIA (610 MM) WEIGHT 2 CWT 2 QTR (127.00 KG.) | No | 1 | |||
| 61 | S&PW-13 | MAKING CONNECTION WITH THE EXISTING G.I. PIPE UPTO 2 INCHES (50 MM) DIA INCLUDING CUTTING THE PIPE AND PROVIDING AND FIXING NECESSARY FITTINGS. | No | 1 | |||
| 62 | S&PW-14 | MAKING CONNECTION WITH THE EXISTING MANHOLE INCLUDING THE COST OF CUTTING HOLES IN WALLS, MAKING THEM GOOD IN CEMENT CONCRETE 1:2:4 AND MAKING THE REQUIRED CHANNEL ETC., COMPLETE. | No | 1 | |||
| 63 | OCW-01 | REMOVING / REFIXING EXISTING KERB STONE (SIZE=12' X 6'' X 18'') INCLUDING REFIXING WITH CEMENT MORTAR 1:3 IN POSITION AS REQUIRED AND ALIGMENT CUTTING / SIZING ETC COMPLETE IN ALL RESPECT AS DIRECTED BY ENGR.-IN-CHARGE. | Rft | 404 | |||
| 64 | OCW-02 | PROVIDING & FIXING GLASS PAPER / DECORATIVE SHEET ON GLASS WITH APPROVED ADHESIVE / SOLUTION INCLUDING THE COST OF CLEANING AND WASHING THE GLASS WITH APPROVED DETERGENT ETC COMPLETE IN ANY FLOOR. | Sft | 608 | |||
| 65 | OCW-03 | PROVIDING & FIXING PLASTIC LOW LEVEL FLUSHING CISTERN 13.6 LITTERS CAPACITY WITH INTERNAL FITTINGS. WITH COMPLETE FITTING ETC. AS DIRECTED BY THE ENGINEER-IN-CAHRGE. | Nos. | 3 | |||
| 66 | OCW-04 | P/F CP MIXER 1/2" DIA FOR WASH BASIN ETC. COPMPLETE IN ALL RESPECTS. | Nos. | 4 | |||
| 67 | EM-01 | WIRING FOR LIGHT, FAN OR CALL BELL POINT WITH (3/.029") PVC INSULATED WIRE IN 20 MM², (3/4") DIA UPVC CONDUIT RECESSED IN THE WALL, COLUMN, ROOF, INCLUDING 1MM² SINGLE CORE PVC INSULATED WIRE AS ECC AS REQUIRED. PAKISTAN CABLES/ FAST/ NEWAGE/ AGE | Points | 26 | |||
| 68 | EM-02 | EXTENSION/ADDITIONAL WIRING FOR LIGHT, FAN, CALL BELL OR LIGHT PLUG POINT, CONTROLLED WITH SAME SWITCH WITH (3/.029”) PVC INSULATED WIRE IN 20 MM (3/4") DIA UPVC CONDUIT RECESSED IN THE WALL, COLUMN OR ROOF INCLUDING 1MM² SINGLE CORE, PVC INSULATED WIRE AS ECC AS REQUIRED. | Points | 28 | |||
| 69 | EM-03 | WIRING FOR PLUG POINT WITH (3/.029") PVC INSULATED WIRE IN 20 MM (3/4") DIA UPVC CONDUIT RECESSED IN THE WALL, COLUMN, ROOF, INCLUDING 1MM², SINGLE CORE PVC INSULATED WIRE AS ECC AS REQUIRED. PAKISTAN CABLES/ FAST/ NEWAGE/ AGE | Points | 28 | |||
| 70 | EM-04 | WIRING FOR SUB-MAIN WITH 2X 2.5 MM², PVC INSULATED WIRE 300/500 VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE IN 20 MM (3/4")DIA UPVC CONDUIT RECESSED IN THE WALL, COLUMN AND ROOF ETC AS REQUIRED. PAKISTAN CABLES/ FAST/ NEWAGE/ AGE | RM | 239 | |||
| 71 | EM-05 | PROVIDING & FIXING 10 AMPS POLYCARBONATE FLAME RETARDANT S.P SWITCH WITH FANCY REQUIRED GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER/PHILIPS) | No. | 28 | |||
| 72 | EM-06 | PROVIDING & FIXING 13 AMPS POLYCARBONATE FLAME RETARDANT 3-PIN SWITCH SOCKET UNIT WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER/PHILIPS) | No. | 28 | |||
| 73 | EM-07 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF 40-42 WATT LED BATTEN LIGHT INCLUDING DRIVER, 6500K COLOUR, 90-110 LUMENS, 0.9 OR ABOVE PFI, 25000 HOURS LIFE CYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY ENGINEER INCHARGE. | No. | 31 | |||
| 74 | EM-08 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED SPOT LIGHTS 10 WATT INCLUDING DRIVER, HAVING WARM / NEUTRAL WHITE/ COOL WHITE COLOUR, 80 LM/WATT EFFICACY, 0.9 OR ABOVE POWER FACTOR 15000-20000 HOURS LIFE CYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY ENGINEER INCHARGE. | No. | 4 | |||
| 75 | EM-09 | PROVIDING & FIXING INDOOR WALL-MOUNTED LED MIRROR LIGHT, AS PER ANNEX B 90–240V AC, BLACK & GOLD FINISH WITH INTEGRATED DUAL-DIRECTIONAL LED LIGHTING, FIXTURE INCLUDES 2× 7-10W LED LIGHT SOURCES (TOTAL 14-20W), ONE FORWARD AND ONE SIDE ON BASE, WITH TRI-COLOR TEMPERATURE SWITCHING (3000K, 4000K, 6000K), 1000–1200 LUMENS. WITH MOUNTING BRACKET AND ALL NECESSARY ACCESSORIES COMPLETE IN ALL RESPECT AS REQUIRED BY ENGINEER IN-CHARGE. | No. | 4 | |||
| 76 | EM-10 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF FLOOD LIGHTS (IP-66) 100 WATT (ROOF MOUNTED) INCLUDING DRIVER, HAVING MULTI COLOUR, 90-110 LM/WATT EFFICACY, 0.9 OR ABOVE POWER FACTOR, 25000 HOURS LIFE CYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY ENGINEER INCHARGE. | No. | 6 | |||
| 77 | EM-11 | PROVIDING AND INSTALLATION OF LED EMERGENCY EXIT LIGHT, DOUBLE-SIDED, 230V AC, 50HZ, 4-7W, WITH HIGH-VISIBILITY LEDS, ≥48 LM IN EMERGENCY MODE, CRI >80, LIFEPO₄ OR NI-CD BATTERY WITH 3-HOUR BACKUP.MOUNTED ON CEILING OR WALL SURFACE, WITH REPLACEABLE DIRECTIONAL LEGENDS (UP, DOWN, LEFT, RIGHT). IP20 INDOOR & IP65 OUTDOOR, CLASS II INCLUDING ALL ACCESSORIES, COMPLETE IN ALL RESPECT AS REQUIRED BY ENGINEER IN-CHARGE. | No. | 1 | |||
| 78 | EM-12 | PROVIDING & INSTALLING FALSE CEILING FAN (BOX FAN) WITH REMOTE, 24" (2' X 2') SIZE INCLUDING CONNECTIONS, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE (VOLDAM/ PAK/ ROYAL) | No. | 6 | |||
| 79 | EM-13 | PROVIDING & INSTALLING 140 CM (56") SWEEP INVERTER CEILING FAN INCLUDING PCB & REMOTE WITH BLADES, CANOPY, STRANDARD LENGTH OF DOWN ROD INCLUDING CONNECTION WITH 14.0076" FLEXABLE WIRE COMPLETE AS REQUIRED. PAK/ GFC/ SK/ ROYAL. | No. | 4 | |||
| 80 | EM-14 | PROVIDING & INSTALLING 45 CM (18") SWEEP WALL BRACKET FAN COMPLETE WITH BLADES, REGULATOR & PULLING CORD SWITCH, FITTED ON WALL OR COLUMN WITH GI CLIP INCLUDING CONNECTION AS REQUIRED. MILLAT/PAK/ GFC/ ROYAL. | No. | 2 | |||
| 81 | EM-15 | PROVIDING & INSTALLING 30 CM (12") SWEEP, METTALIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FITTED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076" FLEXABLE WIRE COMPLETE AS REQUIRED PAK / GFC/ ROYAL. | No. | 2 | |||
| 82 | EM-16 | PROVIDING & INSTALLING 60 CM (24") SWEEP, METTALIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FITTED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076" FLEXABLE WIRE COMPLETE AS REQUIRED PAK / GFC/ ROYAL. | No. | 1 | |||
| 83 | EM-17 | PROVIDING & LAYING NETWORKING CABLE CAT-6 4 PAIR IN 20 MM (3/4") DIA PIPE RECESSED IN THE WALL, COLUMN, ROOF ETC AS REQUIRED. | ft | 93 | |||
| 84 | EM-18 | PROVIDING & FIXING POLYCARBONATE FLAME RETARDANT DATA SOCKET UNIT 8 CONTACT CAT-5 WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED (SCHNEIDER/PHILIPS) | Nos | 7 | |||
| 85 | EM-19 | PROVIDING, INSTALLING, AND COMMISSIONING CUBICAL-TYPE LT DB (2.5′×3.5′), 16 SWG CRCA (ENCL.) & 18 SWG (DOORS), POWDER COATED 70 µM, IP66, VERMIN-PROOF, DOUBLE-LEAF, EPDM GASKET, INTERNAL PROTECTION COVER, LOCK HANDLES, LIFTING HOOKS, REMOVEABLE GLAND PLATES, DUAL EARTH STUDS, 200 A CU TINNED BUSBARS (50 KA/1S, ΔT<35 °C, RYBK, HEAT-SHRINK), 25×3 CU EARTH BAR, FRLSH CU WIRING, CRIMP LUGS, BRASS COMP. GLANDS, CLASS II SPD (IEC 61643), TESTED & COMMISSIONED TO ENG-IN-CHARGE APPR. COMPLETE IN ALL RESPECTS AS REQUIRED BY ENGINEER INCHARGE APPROVAL. INCOMING: 01 NO. 160-250 AMPS. TP MCCB HIGH BREAKING CAPACITY ADJUSTABLE (70KA) OUTGOING: 14 NO. 20-32 AMPS DP MCB 10KA IEC60947-2 07 NO. 20-32 AMPS DP 30MA RCCB (02 TYPE, 04 TYPE AC) 10 NO. 10-16 AMPS SP MCB 10KA IEC60947-2 01 NO. 3 PHASE VOLTMETER LED 480 V (96X96) 500VAC 01 NO. 3 PHASE AMMETER LED 5A (96X96) 30./5A TO 9999/5A 01 NO. PHASE SELECTOR SWITCH 02 SET CTS (300/5A & 100/5A) BUS-BAR TYPE 01 SET BUSBAR (3PHASE+1N) 1000 AMPS. | Job | 1 | |||
| 86 | EM-20 | PROVIDING AND FIXING EARTHING SET WITH 2'X2'X1/84' COPPER PLATE BURIED IN THE GROUND AT A DEPTH OF 12 FEET OR LESS IF WATER COMES OUT FROM THE GROUND LEVEL (WITH SALT AND CHARCOAL, OR EARTHING CHAMICAL POWDER) ETC MAKING THE PIT 12 FEET DEEP BY EXCAVATION OF ALL TYPE OF SOIL (EXCEPT SOFT OR HARD ROCK) I/C FIXING OF 8 SWG COPPER WIRE IN 1/2 '' G.I CONDUIT COMPLETE IN ALL RESPECT AS REQUIRED. | Job | 1 | |||
| 87 | TOTAL | 7540236 | |||||
| GRAND TOTAL: | Rs 7,540,236.00 |
REHABILITATION OF ADMIN BLOCK AT NAWABSHAH AIRPORT
a) Building Works
b) Sanitary & Plumbing Works
c) Other Civil Works
d) Electrical & Mechanical Works
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
The Supplier is:
The title of the subject procurement is: REHABILITATION OF ADMIN BLOCK AT NAWABSHAH AIRPORT
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil
Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
+92-309-799-3589
afaqmalik3589@gmail.com
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil
Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
+92-309-799-3589
afaqmalik3589@gmail.com
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.05% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 5.00% of the contract price in acceptable form of Pay Order, Banker's Cheque, Call at Deposit, Bank Guarantee, Demand Draft
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
As per the conditions of the Contract
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P130483
To: Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., REHABILITATION OF ADMIN BLOCK AT NAWABSHAH AIRPORT (P130483) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: Civil Aviation Training Institute (CATI), Hyderabad - Pakistan Airports Authority PAA (Pakistan Airports Authority (PAA)), Assistant Director Civil Civil Aviation Training Institute, Hyderabad Airport., Hyderabad, Hyderabad (District), Hyderabad (Division), Sindh (Province).
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}
The Bidders shall enter the unit rates, both in figures and words, and the total amount for each item in the BOQ, without making any alteration, addition, or omission to the items therein.
This Bidding Document shall prevail over all other provisions. The Bidder(s) shall sign and stamp this document and upload a scanned copy thereof as part of their Bid submission.