In terms of Rules 65 of Public Procurement Rules, 2026 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP
Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
+92-312-914-8869
meetkarim015@gmail.com
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: Pakistan Airports Authority (Pakistan Airports Authority) The subject of procurement is: PROVISION AND INSTALLATION OF UVSS AND REPLACEMENT OF HYDRAULIC BARRIERS AT BKIAP PESHAWAR Expected commencement date: Monday, December 28, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P169767 |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Saturday, November 14, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on Pakistan Airports Authority (Pakistan Airports Authority) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid:
|
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 180 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Banker's Cheque, Call at Deposit, Demand Draft |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar. Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Tuesday, November 17, 2026 11:00 AM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Tuesday Date: November 17, 2026 Time : 11:30 AM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 5.00%. The Performance Guarantee shall be acceptable in the form of: Pay Order, Bank Guarantee |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
All Active Taxpayers shall be eligible to participate in the procurement process, unless expressly excluded or otherwise restricted under the Eligibility Criteria specified by the Procuring Agency.
| Required Registration |
|---|
| NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) SECP PEC |
| Eligibility Criteria | Document |
|---|---|
| Original Bid Security in favor of Pakistan Airports Authority shall reach office of the undersigned prior to bid submission time as per instruction to Bidders. Bids received without original security shall not be entertained. A Scanned copy shall be uploaded on EPADS. Tender submitted without required earnest money will not be entertained. | Yes |
| Certificate of incorporation / Memorandum & Article of Association or Partnership Deed / Sole Proprietorship on stamp paper Rs. 200 etc. (as applicable) (Attested by Notary Public / Oath Commissioner). | Yes |
| Active Taxpayer Status (ATL), NTN Certificate | Yes |
| Professional Tax Certificate issued by Excise & Taxation Deptt. Govt of Khyber Pakhtunkhwa. | Yes |
| Valid Certification/ License by the Pakistan Engineering Council (PEC) i.e. C-5 (or above) with PEC relevant Specialization Codes i.e. EE-02,EE-04, EE-07,EE-09 ,ME-04 & ME-06. | Yes |
| Affidavit on non-judicial stamp paper Rs. 100 to the effect that the firm has not been blacklisted by any Government, Semi Government and Autonomous Body (Attested by Notary Public / Oath Commissioner). | Yes |
| Details of any arbitration / litigation of similar proceeding against any Govt. / Autonomous / Private body showing extent and results on non-judicial stamp paper Rs. 100 (Attested by Notary Public / Oath Commissioner). | Yes |
| Power of Attorney on stamp paper worthing Rs.500/- (if applicable). | Yes |
| Bidding Documents with each page to be signed and stamped by Authorized Representative of the Bidder. | Yes |
Least Cost Based Selection (LCBS)
Weightage
| Technical Evaluation % |
|---|
| 100 |
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 70 | |
| Financial Capability | ||
| Available Bank Credit Line of min. Rs. 50 Million. (Bank certificate for available credit line shall be required) (Quantitative)(Doc Required) | 7 | |
| Average Annual Turnover of min. Rs.50 Million for the last three (03) years. (Audited Financial Statements shall be required for verification) (Quantitative)(Doc Required) | 8 | |
| Technical Evaluation Criteria | ||
| Clients Profile for Installation/ Testing / Commissioning/ Troubleshooting of UVSS & Road Blockers / automatic Boom Barriers: (Work Order/ Work Completion Certificate shall be required for verification) (Quantitative)(Doc Required) Firm has four (04) No.of distinct clients (20) Firm has three (03) No.of distinct clients (15) Firm has two (02) No.of distinct clients (10) | 20 | |
| Personnel Capability (Quantitative)(Doc Required) 02 Nos. BE (Mechanical/Electrical) having experience of 05 years or above = 10 Marks (05 Mark each) 05 Nos. DAE (Mechanical/Electrical) having experience 03 years or above = 10 Marks (02 Mark each) (20) | 20 | |
| Firm Resource Profile (Quantitative)(Doc Required) Affidavit on (non-judicial) stamp paper enlisting tools / equipment / plant in possession of the firm(s): Excavator / mini-excavator = 05 Marks Hydraulic jack hammer / breaker/ Hydraulic pressure gauge and test kit=03 Marks Forklift=02 Marks Chain block with lifting slings and shackles=04 Marks Welding machine=01 marks Rotary hammer / hammer drill=01 Marks Electric drill machine=01 Marks Portable generator=01 Marks Cable pulling winch=01 Marks Laptop for UVSS configuration=01 Marks (20) | 20 | |
| Experience in Installation/ Testing / Commissioning/ Troubleshooting of UVSS & Road Blockers / automatic Boom Barriers: (Work Order/ Work Completion Certificate shall be required for verification) (Quantitative)(Doc Required) Firm has successfully completed five (05) projects (25) Firm has successfully completed four (04) projects (20) Firm has successfully completed three (03) projects (15) | 25 | |
Lot Title : Provision & Installation of Under Vehicle Surveillance System (UVSS) and Replacement of Hydraulic Road Blockers at BKIAP Peshawar
Bid Security : 900000 PKR
| Job | Delivery Schedule | Quantity |
|---|---|---|
| E&M Works |
Address: Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
Schedule: 90 Days
Quantity: 1/job
|
1/job |
| Civil Works |
Address: Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
Schedule: 90 Days
Quantity: 1/job
|
1/job |
| CNS Works |
Address: Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
Schedule: 90 Days
Quantity: 1/job
|
1/job |
No
Lot Title: Provision & Installation of Under Vehicle Surveillance System (UVSS) and Replacement of Hydraulic Road Blockers at BKIAP Peshawar
Specifications / Requirements:
| Sr. No | Ref. No. | Description | Unit | Qty | Rate | Figure | Amount |
|---|---|---|---|---|---|---|---|
| 1 | 1 | Providing, supply, installation, testing, and commissioning of an Automatic Boom Barrier System suitable for security checkpoints, comprising a heavy-duty automatic boom barrier with minimum 5 million MTFB/MCBF, supporting a straight or folding boom arm up to 6.0 meters, driven by a high-performance electromechanical motor for continuous 24/7 operation, with adjustable opening and closing speeds for medium to high traffic. The system shall include an integrated control panel interfaced with UVSS, access control systems, and push buttons, along with safety features such as obstacle detection, emergency stop, and manual release, housed in an outdoor-rated, corrosion-resistant enclosure. The scope shall also include supply and installation of a VR10 radar vehicle detection system (as an alternative to inductive loop detector) for detection of stationary and moving vehicles, fully interlocked with the boom barrier control logic for safety and automatic operation. The system shall operate on 220–240 VAC, 50 Hz and include all civil works (excavation, concrete foundation, anchor bolts, conduits, and reinstatement), complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 02 | |||
| 2 | 2 | Supply, installation, testing, and commissioning of an Automatic parking Boom Barrier System suitable for haevy traffic, comprising a heavy-duty automatic boom barrier with minimum 5 million MTFB/MCBF, supporting a straight or folding boom arm up to 6.0 meters, driven by a high-performance electromechanical motor for continuous 24/7 operation, with adjustable opening and closing speeds for medium to high traffic. The system shall includeloop detector long rang reader (MTAG) with all assessories,LPR Cameras with stand ,16 channel NVR,ticket dispenser kiosk, access control systems, and push buttons, along with safety features such as obstacle detection, emergency stop, and manual release, housed in an outdoor-rated, corrosion-resistant enclosure. The system shall operate on 220–240 VAC, 50 Hz and include all civil works (excavation, concrete foundation, anchor bolts, conduits, and reinstatement), complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 02 | |||
| 3 | 3 | Dismantaling of existing old hydraulic barrier along with all accessoriesand shifting in store as per requirment as approved by engineer incharge . | P.Job | 02 | |||
| 4 | 4 | Providing, installation, testing and commissioning of Split type wall mounted air conditioner T3 DC Inverter,in the specified place. The job includes connection of copper piping of outdoor unit fitted on roof or angle iron frame, making inter connection of the unit with suitable sizes of wire also piping for condensed water , refrigerant top up etc as required approved make (Imported). a. 0.9 Ton -1 Ton (10800BTU-12000BTU) | P/Job | 04 | |||
| 5 | 5 | Supply, installation, testing & commissioning of hydraulic barrier (road blocker),10-12 feet span with Siemens motor (7.5 HP ar above ), having following specifications: Limit switch (humidity prrof) solinoid valve for reliability & safety in operation, Maximum running pressure 25 bar (approx), must interface with access control system , Load bearing capacity of appprox 40 metric ton, Raising /lowering time 6-8 seconds, Operating temprature ranging from -20c° to 50c°, Manual override (in case of power failure),constructed in heavy duty grade keeping in view the actual entrance size. The barrier includes submersible pupm for water drainage , complete with all related accessories, as approved by engineer incharge. | P.Job | 02 | |||
| 6 | 6 | Providing & laying 4 core, 10 mm2 , stranded copper conductor, PVC insulated and PVC sheeted cable I/c 2.5mm2 single core PVC insulated wire ECC in all kind of existing or given conduite /duct as required. | P/Mtr. | 100 | |||
| 7 | 7 | Providing & fixing 10-60 Amps (High breaking capacity) TP MCCB fixed on existing board, i/c inter connection as required. | Ea. | 02 | |||
| 8 | 8 | Wiring for sub-main with 4 core, 6 mm2, stranded copper conductor, PVC insulated & uPVC sheathed cable in 30mm (1 ¼”) dia high pressure ‘D’ class uPVC conduit buried in ordinary soil at the depth of 0.5 meter including 2.5 mm2 PVC insulated wire single core wire as ECC as per Pak. P.W.D. Specifications as required. | P/Mtr | 105 | |||
| 9 | 9 | Wiring for sub-main with 2x4 mm2,, PVC insulated wire 300/500 volts grade , single core, stranded copper conductor wire in 20mm (3/4”) dia uPVC conduit recessed in the wall , column & roof etc i/c 1.5mm2 PVC insulated wire single core wire as ECC as required. | P/Mtr | 20 | |||
| 10 | 10 | Supply an drawing of 2x2.5 mm2,single core,PVC insulated wire including 1 mm2 PVC insulated wire single core wire as ECC in all kinds of existingor given conduit/cable duct as required. | P/Mtr | 60 | |||
| 11 | 11 | Wiring for sub-main with 2x2.5 mm2,, PVC insulated wire 300/500 volts grade , single core, stranded copper conductor wire in 16x16 mm uPVC duct fiited on surface including 1.5mm2 PVC insulated wire single core wire as ECC as required. | P/Mtr | 40 | |||
| 12 | 12 | Providing & fixing flush type,6/10Amps, 3-Pin socket & double switches combine unit (Universal) fixed on Plastic or fiber top covered sheet on(14SWG) metal board with earth terminal recessed in wall and column including, connection as required. | Each | 6 | |||
| 13 | 13 | Providing & fixing flush type, 15 Amps, Porcelain base, 3-Pin switch & socket combine unit with neon bulb (Power plug) fixed on Plastic or fiber top covered sheet on (14SWG) metal board with earth terminal recessed in wall & column,including connection as required. | Each | 4 | |||
| 14 | 14 | Providing & fixing 10 Amps Polycarbonate flame retardant S.P switch with fancy"Ivory" gang plate fixed on dia fabricated,powder coated, metal board recessed in the wall or column including connection as required.(MATRIX/SOK/TJ SERIES/TRUST make). | Each | 10 | |||
| 15 | 15 | Providing & fixing 10 Amps Polycarbonate flame retardant 2-Pin switch socket unit ( Universal) with fancy gang plate fixed on die fabricated, powder coated metal board recessed in wall or column including connection as required.(Schneider/Philips) . | Each | 4 | |||
| 16 | 16 | Providing, Installation ,Testing & commissioning of Flood lights (IP66) including driver having neutral white/cool white colour,110-120 lm/watts efficiency,0.9 or above power factor,20000-25000 hours life cycle, including connection, complete in all respect as approved by the engineer Incharge. b) 50-70 Watts | Each | 4 | |||
| 17 | 17 | Providing, installation, Testing & Commissioning of high bay Lights including driver, having warm / neutral white / cool white colour, 100-120 Im/watt efficieny, 0.9 or above power factor, 20000-25000 hours life cycle, including connection, complete in all respect as approved by Engineer incharge. a) 80-100 Watts | Each | 6 | |||
| 18 | 18 | Providing, installation, Testing & Commissioning of LED Tube / batten Lights including driver, having warm / neutral white / cool white colour, 80-90 Im/watt efficieny, 0.9 or above power factor, 10000-15000 hours life cycle, including connection, complete in all respect as approved by Engineer incharge. b) 4 feet 18-20 Watts | Each | 2 | |||
| 19 | 19 | Providing & installing 140 Cm (56") sweep ceiling fan with blades, canopy,standerd length of down rod including connection with 14.0076" flexible wire complete as required.(without regulator). Pak,Royal,GFC,Younas,Millat. | Each | 4 | |||
| 20 | 20 | Providing & installing 45 Cm (18") sweep wall bracket fan complete with blades, regulator & pulling cord switch, fitted on wall or column with GI clip including connection as required. Pak,Royal,GFC,Younas,Millat. | Each | 2 | |||
| 21 | 21 | Providing / fixing testing & commissioning of metal clad cubical type Distribution Board size 18"x24"’ (min. 10" depth) with locking arrangement complete with circuit breakers 3-Phase, indication lamps, to be mounted on wall as per site requirement and instruction of Engineer Incharge having following specification:- Incoming 100A 3- pole MCCB 3-Phase --- 01 No. Indication Lamps - 03 Nos Outgoing 6-10 Amp S- pole MCB-----03 Nos 20 Amp 2 Pole MCB-----02 Nos 32 Amp 3 Pole MCB-----01 Nos | P.Job | 2 | |||
| 22 | Total Sub Head I (E&M Portion) Rs. | ||||||
| 23 | Sub Head-II A Civil Works | ||||||
| 24 | 1 | Dismantling lime or cement concrete in foundation or under floor basement, plinth and ground floor and disposing of surplus material as directed within three chains (91.5 m). | 100 Cft | 95 | |||
| 25 | 2 | Dismantling bitumen carpet of any description from existing road surface including its removal and disposal within three chains (91 m) lead as desired. | 100 Sft | 455.125 | |||
| 26 | 3 | Dismantling of stone metalling from existing road from where bitumen carpet has already been removed and stacking the useful material within one chain (30.5 m) lead including disposal of surplus stuff within 3 chains (91 m) lead as desired. | 100 Cft | 54 | |||
| 27 | 4 | Excavation for foundation trenches and drains in all kinds of soil (except gravelly and murum soil, wet silt, clay or mud conglomeration of gravel and boulders, soft, sandy or disintegrated sandy and hard rock) and back filling the excavated material in foundation, plinth or under floor including breaking clods, watering, consolidation by ramming in layers not exceeding 9 inches (229 mm) in depth to full compaction, dressing and disposal of surplus excavated stuff as directed, lead upto one chain (30.5 R.m) and lift upto 5 feet (1.52 m). | 100 Cft | 217.25 | |||
| 28 | 5 | Providing and laying 1:4:8 (1 cement 4 sand and 8 coarse aggregate) cement concrete using graded gavel (bajri) 1 inch (25 mm) and down gauge in foundation including levelling, compacting and curing etc.complete. | 100 Cft | 35.5625 | |||
| 29 | 6 | Providing and fixing un platisized polyvinyl chloride pipe (P.V.C) "D" class and specials etc. including cutting and fitting complete with and including the cost of cutting trench upto 1-1/2 feet deep refilling, watering, ramming, and disposal of surplus earth within one chain and after cleaning the pipe and cartage within 10 miles (16.09 km.) (working pressure 12 kg/cm2 ) 4 inches (100 mm) dia. | P.Rft | 55 | |||
| 30 | 7 | Providing and fixing un platisized polyvinyl chloride pipe (P.V.C) "D" class and specials etc. including cutting and fitting complete with and including the cost of cutting trench upto 1-1/2 feet deep refilling, watering, ramming, and disposal of surplus earth within one chain and after cleaning the pipe and cartage within 10 miles (16.09 km.) (working pressure 12 kg/cm2 ) 2 inches (50 mm) dia. | P.Rft | 40 | |||
| 31 | 8 | Providing and laying 6" (153 mm) thick cement concrete not leaner than 1: 1-1/2:3 (minimum works cube strength of 2812 PSI or 198 Kg/Sq.cm. at 28 days) in roads, paths, crete-ways etc. using graded screened bajri in panels of approved size laid to required gradient and camber including cost of necessary form work and its removal, compacting with vibrators (immersion or screen or both) belting and roughening the surface after laying concrete, with brush and curing etc., complete. | 100 Sft | 384 | |||
| 32 | 9 | Providing and laying hard grade ribbed deformed (minimum yield point 60,000 psi) reinforcement bars with & including the cost of straightening, cutting, bending, binding, wastage, and such overlaps as are not shown in the drawings, placing in position on cement concrete 1:2:4 precast or m.s. chairs, tying with binding wire, cost of chairs and wires etc. in all kinds of RCC work in foundation, basement, plinth and ground floor of building including septic tanks and under ground tanks and in projections for future extension. | P.Kg | 139 | |||
| 33 | 10 | Providing and laying reinforced cement concrete using crushed graded boulder 3/4 inch (19 mm) and down gauge having a minimum works cube crushing strength of 3000 Ibs. per sq inch (20.69 N/mm2 ) at 28 days with a mix not leaner than 1:2:4 in column footing of required shape including form work and its removal, compacting and curing etc. complete but excluding the cost of reinforcement, in foundation basement and plinth. | 100 Cft | 40 | |||
| 34 | 11 | Providing and laying reinforced cement concrete using crushed graded boulder 3/4 inch (19 mm) and down gauge having a minimum works cube crushing strength of 3000 Ibs. per sq inch (20.69 N/mm2) at 28 days with a mix not leaner than 1:2:4 in columns of square or rectangular shape of regular section including form work and its removal, compacting and curing etc. but excluding the cost of reinforcement, in foundation basement and plinth. | 100 Cft | 39 | |||
| 35 | 12 | Providing and fixing M. S. tees, angles and flats including welding all the sides of the section at the junction, gusset plates, bolts, nuts etc. complete with hoisting and erecting in position in steel trusses, frames, towers etc. of any design in ground floor. | P.Kg | 174 | |||
| 36 | Total Sub Head II A: Rs. | ||||||
| 37 | Sub Head II B: Canopy Shed | ||||||
| 38 | 1 | Dismantling bitumen carpet of any description from existing road surface including its removal and disposal within three chains (91 m) lead as desired. | 100 Sft | 150 | |||
| 39 | 2 | Excavation for foundation trenches and drains in gravelly soil and back filling the excavated material in foundation trenches plinth or under floor including breaking clods, watering, consolidation by ramming in layers not exceeding 9 inches (229 mm) in depth to full compaction, dressing and disposal of surplus excavated stuff as directed lead upto one chain (30.5 R.m) and lift upto 5 feet (1.52 m). | 100 Cft | 144 | |||
| 40 | 3 | Providing and laying 1:4:8 (1 cement 4 sand and 8 coarse aggregate) cement concrete using graded gavel (bajri) 1 inch (25 mm) and down gauge in foundation including levelling, compacting and curing etc.complete. | 100 Cft | 18 | |||
| 41 | 4 | Providing and laying 1:2:4 (1 cement 2 sand and 4 coarse aggregate) cement concrete using crushed graded boulder (machine broken) 1inch (25 mm) and down gauge in foundation including levelling, compacting and curing etc. complete. | 100 Cft | 144 | |||
| 42 | 5 | Providing/ errecting in position vertically M.S Pipe 8" dia (14 Gauge), 20' in height of approved quality, welded M.S plate 12"x12"x1/4" thick on bottom & top of pipe and cross angle iron 2" x 2" x 3/16" with necessary welding properly where its required etc complete as directed by the Engineer Incharge. | P.Rft | 80 | |||
| 43 | 6 | P/F M.S pipe Truss 1'-6" height consisting of (2" x 2") & (2"x1-1/2") rectangular pipe (18 guage) welded horizontaly, vertically and inclined as per drawing I/c welding all the sides of section at the junction with existing pipes,gusset plates properly where its required complete as directed by the Engineer Incharge. | P.Rft | 120 | |||
| 44 | 7 | P/F M.S pipe (2" X 2") rectangular (18 guage) Frame as per drawing i/c welding all the sides of section at the junction with existing pipes properly where it is required complete as directed by the Engineer Incharge. | P.Rft | 550 | |||
| 45 | 8 | Painting iron work with enamel paint of approved make and shade two coats over and including the cost of one coat of priming complete at any height in any floor. | 100 Sft | 894 | |||
| 46 | 9 | P/F Fiber glass sheet/ canopy 5mm thick with existing frame I/c the cost of nut bolts limpet washers, silicone tube, adhesive material/ chemicals etc complete as directed by the Engineer Incharge. | P.Sft | 750 | |||
| 47 | 10 | Removing the existing worn out bituminous surface, having pot holes and ruts in patches of regular shape brushing and re-carpeting with 2" (51 mm) thick (consolidated) asphalt macadam as per specifications complete, including disposal of excavated stuff within one chain (30.5 m) lead as desired. | 100 Sft | 114 | |||
| 48 | Total Sub Head II B: Rs. | ||||||
| 49 | Sub Head III: CNS Works | ||||||
| 50 | 1 | Supply, Installation, Testing, Commissioning & Integration of Complete Area Scan UVSS System Package including civil work complete installation (all-Inclusive)Stationary Under Vehicle Surveillance System (UVSS) 1) UVSS Scanning Module Image Resolution: Up to 20MP, 2K per line Field of View: 180° Imaging Time: < 1 second after trigger Max Vehicle Speed: 80 km/h (recommended < 50 km/h) Vehicle Compatibility: o Chassis height: ≥ 60 mm o Chassis width: ≤ 4500 mm Load Bearing: 50 tons Illumination: 240W dynamic LED array Material: Stainless steel Protection: IP68 (dust & waterproof) Operating Temperature: -40°C to +85°C Dimensions: 900 × 190 × 180 mm Weight: 50 kg UVSS Industrial Computer CPU: Intel Core i5-4570, 3.2 GHz Memory: 8 GB DDR3L Storage: 1 TB SATA HDD + 128 GB SSD Graphics: VGA & HDMI (1920×1200 @ 60 Hz) Network: 2× Gigabit Ethernet OS: Windows 7 Pro 64-bit Power: ≤ 250 W Operating Temp: 0°C to 60°C UVSS Controller Input Power: 48V / 240W Interfaces: GigE, RS485 Supports: Scan camera, ANPR camera, LED modules Certifications: CE / FCC / UL Operating Temp: -35°C to +60°C Dimensions: 137.5 × 190 × 95.4 mm Power System Input Voltage: 90–264 VAC Output: 48V DC, 7.3A Rated Power: 350 W Protections: Overload, over-voltage, over temperature Operating Temp: -20°C to +70° Resolution: 2MP (1920×1080) WDR: Up to 140 dB Lens: Motorized (approx. 2.7–12 mm / 3.2–10.5 mm) Recognition Speed: < 40 km/h Functions: Plate capture, vehicle snapshot, white list control Protection: IP67, IK10 Power: DC 12V / PoE Operating Temp: -40°C to +60°C Display Size: 20.7" (16:9) Resolution: 1920×1080 (FHD) Brightness: 250 cd/m² •Inputs: VGA, HDMI Power Consumption: 23 W Loop Sensor Working Voltage: ≤ AC 250V / DC 500V Operating Temp: -60°C to +80°C Application: Vehicle trigger detection two (02) mounting poles; CAT-6 or fiber optic cable (FOC) cabling for complete system where required; inc. software configuration; testing, calibration; and one-time on-site training by OEM. The job shall also include all associated civil works, including excavation, RCC foundations for UVSS, camera poles and equipment, trenching, conduit laying, inductive loop cutting, laying, sealing and reinstatement, surface restoration, and all allied civil works complete in all respects, as per attached specifications and to the satisfaction of the Engineer-in-Charge. | P/Job | 2 | |||
| 51 | 2 | Providing, supply, installation, testing, and commissioning of Rack Mount Smark True Online Uninterruptible Power Supply (UPS) systems of 3 kVA capacity with long back up, based on double-conversion technology with pure sine wave output, built-in Automatic Voltage Regulation (AVR), LCD status display, and USB/communication interface for monitoring and diagnostics, complete with internal batteries. The UPS systems shall be suitable for continuous operation and for powering server rack equipment, networking devices, and security systems, complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 2 | |||
| 52 | 3 | Providing, supply, installation, testing, and commissioning of Artifical Intelligence License Plate 4 MP Speed Detection Cameras with installation Accessories Generic Specifications • Camera Type: 4MP AI ANPR (Automatic Number Plate Recognition) • AI & Smart Features: o Deep learning-based LPR engine o Vehicle detection with high accuracy o Direction detection, license plate recognition, vehicle size & color detection o Vehicle structuring for data analysis • Vehicle Detection Capabilities: o Sizes: 11 types (large bus, heavy truck, medium truck, sedan, minivan, light truck, SUV, MPV, medium bus, pick-up, minicar) o Colors (Daytime): 11 colors (white, black, blue, red, yellow, green, pinkish purple, gray, brown, orange, silver) • Performance & Database: o White List: Supports 10,000 records o Vehicle capture rate: ≥ 99% o Minimum detection speed: 60 km/h • Video & Encoding: o H.265 & H.264 dual-stream encoding • Storage & Lens: o Micro SD memory support o Powerful motorized lens • Illumination & Capture Range: o Built-in white light o IR Illumination Distance: 30m (98.43 ft) o Capture Distance: 8m–30m o Minimum Illumination: 0.002 lx (with illuminator on) • Protection: o IP67 (Weatherproof) o Designed for outdoor applications complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 2 | |||
| 53 | 4 | Providing/Installation ,testing & commissioning of Mini PTZ Speed Dome Cameras for Outdoor Surveillance Generic Specifications • Resolution: 2MP (1920 × 1080) @ 25/30fps • AI & Smart Features: o Deep-learning-based Pro AI o Perimeter Protection o Video Structurization o Smart Motion Detection (SMD) • Optical & Low-Light Performance: o Zoom: 25× Optical Zoom o Low Light: Starlight technology • Compression: H.265 • IR & Illumination: IR distance up to 100m • Mechanical & Environmental: o Tilt range: -15° ~ 90° o Operating Temperature: 40°C ~ 70°C o Weatherproof: IP66 • Power: PoE+ Warranty: 2 years complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 2 | |||
| 54 | 5 | Providing/Installation ,testing & commissioning of 08 Port Industrial Grade POE Network Managed Gigabit Switch. ➢ 8 Ports Industrial Full Gigabit Poe Managed Switch Provide 8* 10/100/1000Base-T Ethernet ports (Poe) + 2* 1000BASE-X SFP Ports. ➢ Support 4K high-definition video transmission; PoE Function: support IEEE802.3af/at standard, each port supports up to 60W PoE Output. ➢ Support Web-based network management, support VLAN, QoS, RSTP, SNMP, Support IGMP Snooping etc. ➢ Network function. ➢ Support 4K VLAN, Support 802.1Q Protocol-Based VLAN, Support PortBased VLAN. ➢ Support Fast Ring as redundant link Support relay alarm for power off, network broken, PoE off, 6KV surge immunity, 8KV ESD Protection and anti-interference ability; -40℃~75℃ working temperature. ➢ Support redundant Power Supply Rail/Rack kit Fitting, CE、FCC、ROHS Certified. Two Years Warranty complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 2 | |||
| 55 | 6 | Providing/Installation ,testing & commissioning of 16CH Network Video Recorder with 16 TB HDD. Key Points Max. 448/448/448 Mbps Incoming/Recording/Outgoing Bandwidth Max. Decoding Capability: 40 × 1080p@30 fps IP Cameras Resolution Up to 32MP 8K HDMI Output 2 Bays. Each HDD Storage Capacity Up to 26TB complete in all respects as per specifications and instructions of the Engineer-in-Charge. | P/Job | 2 | |||
| 56 | Total Sub Head III: Rs. | ||||||
| 57 | G.Total: Sub Head I+SubHead II A+SubHead IIB+Sub Head III (Rs.) | 35565358 | |||||
| GRAND TOTAL: | Rs 35,565,358.00 |
|
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
The Supplier is:
The title of the subject procurement is: PROVISION AND INSTALLATION OF UVSS AND REPLACEMENT OF HYDRAULIC BARRIERS AT BKIAP PESHAWAR
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP
Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
+92-312-914-8869
meetkarim015@gmail.com
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP
Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
+92-312-914-8869
meetkarim015@gmail.com
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.05% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 5.00% of the contract price in acceptable form of Pay Order, Bank Guarantee
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
For being Brand New, bearing relevant reference numbers of the equipment (Certificate from supplier)
For Physical Fitness having No Damages (Certificate from supplier)
For the Country of Origin as quoted by the Supplier (Certificate from manufacturer)
For conformance to specifications and performance parameters, through Prior to delivery inspection (Inspection Report by Procurement Committee / Inspection Team)
For successful operation at site after complete installation, testing and commissioning of the equipment (Installation, Testing and Commissioning Report by Procurement Committee / Inspection Team)
Copies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount;
Original and two copies of the usual transport document (for example, a negotiable bill of lading, a non-negotiable sea waybill, an inland waterway document, an air waybill, a railway consignment note, a road consignment note, or a multimodal transport document) which the buyer may require to take the goods;
Copies of the packing list identifying contents of each package;
Insurance Certificate;
Manufacturer’s or Supplier’s Valid Warranty Certificate;
Inspection Certificate issued by the Nominated Inspection Agency (if any), and the Supplier’s Factory Inspection Report;
Certificate of Origin.
The above documents would be required even if the equipment has already been imported and is available with the supplier ex-stock
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P169767
To: Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., PROVISION AND INSTALLATION OF UVSS AND REPLACEMENT OF HYDRAULIC BARRIERS AT BKIAP PESHAWAR (P169767) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: Pakistan Airports Authority (Pakistan Airports Authority), Divisional Engineer ES (E&M), BKIAP Office of the Divisional Engineer ES (E&M), Bacha Khan International Airport, Peshawar.
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}