In terms of Rules 65 of Public Procurement Rules, 2026 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.gov.pk).
Quetta Airport (Pakistan Airports Authority (PAA)), Secretary
Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
+92-322-826-8402
rasheedbizenjo35@gmail.com
The following specific data for the procurement of works shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITBs). Whenever there is a conflict, the provisions herein shall prevail over those in ITBs.
ITB Number 1.1
Name of Procuring agency/Employer: Quetta Airport (Pakistan Airports Authority (PAA))
The subject of procurement is: Operationalization of Dalbandin Airport (Rehabilitation of Airside Pavements, Security Fence, PTB and Allied Works)
Period for completion of the works 24 Months
Commencement date execution of the works: 15 Days
Type of Procurement: Local
ITB Number 2.1
Financial year for the operations of the Procuring agency/Employer: 2026-27
Name of Project :
Name of financing institution:
Name and identification number of the Contract: P202140
ITB Number 3.1
JV/Consortium or Association Allowed: No
Maximum number of members in the joint venture shall be: Nil.
ITB Number 6.4
The Bidders may seek clarifications through EPADS v2.0: Last Clarification Date: Sunday, November 22, 2026
ITB Number 8.1
The Language of all correspondences and documents related to the Bid is: English
ITB Number 5.1 & 9.1
The following documents must be included to constitute the Bid
ITB Number 9.4 (b)
Other procurement specific documentation requirements are:
Signed / Stamped Bidding Document
ITB Number 12.4
The Bid price will be/will not be subject to the price adjustment Yes
Price Adjustment Annexure is attached in the Annexure Section with the name of Adjustment Data.
ITB Number 12.6
The Bid price shall be adjusted in accordance with Schedule-A to Bid – “Schedule of Adjustment Data” if available.
ITB Number 13.1
Bidders to quote entirely in Pak rupees (PKR)
Schedule of Adjustment Data for Local Currency (LC)
| Index Code | Index Description | Source of Index | Weighting |
|---|---|---|---|
| 1 | Non-adjustable | --- | 0.30 |
| 2 | Labour | PBS Statistical Bulletin | 0.16 |
| 3 | Steel | PBS Statistical Bulletin | 0.05 |
| 4 | Cement | PBS Statistical Bulletin | 0.11 |
| 5 | Bitumen | PARCO / Attock Notification | 0.05 |
| 6 | Aggregate | PBS Statistical Bulletin | 0.20 |
| 7 | HSD | OGRA / PSO | 0.13 |
| Total | PKR | 1.00 |
ITB Number 15.1
The Bid Validity period shall be 90 Days days.
ITB Number 16.1
The amount of Bid Security shall be ... see section itemd and bid security
The currency of the Bid Security shall be: PKR.
ITB Number 16.2
The Bid Security shall be in the form of:
ITB Number 19.1
The deadline for Bid submission is: Wednesday, November 25, 2026 02:00 PM
Address for submission of Original Bid Security: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
ITB Number 21.1
The Bid opening shall take place at: EPADS v2.0
Day : Wednesday
Date: November 25, 2026
Time : 02:30 PM
ITB Number 27.1
The currency that shall be used for Bid evaluation and comparison purposes to convert all Bid prices expressed in various currencies is: PKR Only
The source of exchange rate shall be: Nil
The date of exchange rate shall be: Nil
ITB Number 28.2 & 28.5
Least Cost Based Selection (LCBS)
see Evaluation Criteria
ITB Number 29.1
Domestic preference to apply.
Domestic preference: Yes
The Percentage of Domestic Preference is 90%
Preference to domestic or national suppliers or contractors shall be provided in accordance with policies of the Federal Government and/or in accordance with the regulations issued by the Authority.
If Yes, The percentage for the domestic preference alongwith calculation formula is provided in the evaluation and qualification criteria.
ITB Number 32.2
Sub-contracting is allowed? : Yes
30 % of the total value of the contract.
39.1 The Performance Security (or guarantee) shall be 0%
39.2 The Performance Security (or guarantee) shall be in the form of: Nil
All Active Taxpayers shall be eligible to participate in the procurement process, unless expressly excluded or otherwise restricted under the Eligibility Criteria specified by the Procuring Agency.
| Required Registration |
|---|
| NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) PEC |
Least Cost Based Selection (LCBS)
Lot Title : Rehabilitation of Dalbandin Project
Bid Security : 0 PKR
| Job | Delivery Schedule | Quantity |
|---|---|---|
| Rehabilitation of Airside Pavements |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Access Road |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Ancillary Civil Infrastructure |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Renovation of PTB |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Public Health Engineering |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Security Infrastructure |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| External Electrical Infrastructure |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Building Electrification & Life Safety |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365 Days
Quantity: 1/job
|
1/job |
| Mechanical Works |
Address: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Schedule: 365Days
Quantity: 1/job
|
1/job |
Lot Title: Rehabilitation of Dalbandin Project
Specifications / Requirements:
| Sr. No | REF | DESCRIPTION | UNIT | QUANTITY | RATE | AMOUNT |
|---|---|---|---|---|---|---|
| 1 | SH1 | DEMOLITION OF PREMIX CARPET / BITUMINOUS PAVEMENTS, LOAD MATERIAL FOR DISPOSE OFF AND LEAD UPTO 5 KM OUTSIDE AIRPORT PREMISES | CUM | 120999 | ||
| 2 | SH1 | CUTTING OF ORDINARY / HARD SOIL OF ROADWAY / RUNWAY / HARD STANDING STRIPPING ETC AND DISPOSE OFF / COLLECT SPOIL WITHIN 5 KM COMPLETE | CUM | 101 | ||
| 3 | SH1 | COMPACTION OF NATURAL GROUND UP TO 95% MODIFIED AASHTO DENSITY ALL AS SPECIFIED | SQM | 100750 | ||
| 4 | SH1 | EXCAVATION AS IN ORDINARY / HARD SOIL UPTO 1.50 MTR DEPTH IN FOUNDATIONS OR TRENCHES, THROW EARTH CLEAR OF EDGES OF EXCAVATION INCL LOADING AND UNLOADING AND UP TO 10 KM LEAD | CUM | 6971 | ||
| 5 | SH1 | PROVIDING AND LAYING IMPROVED SUBGRADE USING 80% EXISTING EXCAVATED MATERIAL TO ACHIEVE 95% MODIFIED AASHTO DENSITY COMPLETE | CUM | 27670 | ||
| 6 | SH1 | PROVIDING AND LAYING IMPROVED SUBGRADE USING 20% GRANULAR MATERIAL TO ACHIEVE 95% MODIFIED AASHTO DENSITY COMPLETE | CUM | 6917 | ||
| 7 | SH1 | BOTTOMING / SUB BASE OF ANY THICKNESS AS SPECIFIED USING GRANULAR MATERIAL OF CBR 30% LAID AND COMPACTED TO 100% MODIFIED AASHTO DENSITY BY APPROPRIATE COMPACTION COMPLETE | CUM | 34588 | ||
| 8 | SH1 | PROVISION AND INSTALLING OF HDPE GEOGRID BIAXIAL IN PAVEMENT STRUCTURAL LAYERS AS PER OEM RECOMMENDATIONS AND DIRECTIONS OF ENGINEER IN CHARGE. | SQM | 70000 | ||
| 9 | SH1 | PROVISION AND INSTALLING OF HDPE GEOCELLS (CELL DEPTH 150MM, CELL SIZE 440 MM, SHEET THICK 1.5 MM) IN PAVEMENT STRUCTURAL LAYERS AS PER OEM RECOMMENDATIONS AND DIRECTIONS OF ENGINEER IN CHARGE. | SQM | 70000 | ||
| 10 | SH1 | AGGREGATE BASE COURSE OF ANY THICKNESS AS SPECIFIED LAID AND COMPACTED TO 100% MODIFIED AASHTO DENSITY BY APPROPRIATE COMPACTION EQUIPMENT AND ROLLER | CUM | 43189 | ||
| 11 | SH1 | PRIME COAT ON BASE COURSE SURFACE COMPLETE | SQM | 113400 | ||
| 12 | SH1 | PROVIDING AND LAYING (BATCHING-PLANT-MIXED) ASPHALT BASE COURSE OF ANY THICKNESS IN LAYERS AS SPECIFIED WITH ASPHALT CONCRETE IN 60/70 OR 80/100 GRADES USING APPROVED JMF COMPLETE (EXCEPT PRIME COAT) | TON | 27784 | ||
| 13 | SH1 | TACK COAT ON ASPHALTIC SURFACE COMPLETE | SQM | 113400 | ||
| 14 | SH1 | PROVIDING AND LAYING (BATCHING-PLANT-MIXED) ASPHALT WEARING COURSE OF ANY THICKNESS IN LAYERS AS SPECIFIED WITH AASPHALT CONCRETE IN 60/70 OR 80/100 GRADES USING APPROVED JMF COMPLETE (EXCEPT TACK COAT) | TON | 13892 | ||
| 15 | SH1 | BLEND ADDITIVE(S) SBS/SBR/PEVA IN BITUMEN BINDER TO MAKE IT PMB PG 76-22 COMPATIBLE FOR USE IN ASPHALT CONCRETE AS SPECIFIED. | TON | 137 | ||
| 16 | SH1 | LABOUR AND NECESSARY MATERIAL FOR FORMING OF EXPANSION JOINT 13 MM WIDE AND LEAVING THE JOINT CLEAR FOR FILLING (LENGTH OF JOINT MULTIPLIED BY THICKNESS OF JOINT) | SQM | 15 | ||
| 17 | SH1 | PROVIDING AND FILLING OF RIGID PAVEMENT JOINTS 3/4 INCH X 5/8 INCH (AVERAGE) WITH JET FUEL RESISTANT SEALANT (CRAFCO USA OR EQUIVALENT IMPORTED) CONFORMING TO ASTM D6690 INCL REMOVAL/CLEANING OF EXISTING SEALANT, CLEANING INTERFACES BY SAWING OR MECHANICAL ABRASION, BLOWING DRY WITH COMPRESSOR, DISPOSAL OF RUBBISH AND P/L BACKER ROD/RUBBER STRIP | METRE | 2561 | ||
| 18 | SH1 | FILLING OF JOINT WITH AEROLASTIC MATERIAL INCL FOAM ROPE (BACKER ROD), CUTTING WITH SAW | METRE | 110 | ||
| 19 | SH1 | P/L OF LEAN CONCRETE USING CRUSHED OR BROKEN STONE GRADED 1:4:8 ALL AS SPD | CUM | 431 | ||
| 20 | SH1 | PROVIDING AND LAYING PCC 1:2:4 CONCRETE USING CRUSHED OR BROKEN STONE GRADED ALL AS SPD | CUM | 1394 | ||
| 21 | SH1 | PROVIDING AND LAYING PCC 1:2:4 AS IN FLOOR SLABS SURFACE FINISHED SMOOTH WITH NEAT CEMENT AND STEEL TROWEL USING CRUSHED OR BROKEN STONE FOR BASEMENT / GROUND FLOOR | CUM | 183 | ||
| 22 | SH1 | PROVIDING AND LAYING PQC FLEXURAL STRENGTH OF 600 PSI FOR RUNWAY TAXIWAY LINKS LEAD-INS AND TARMAC OF ANY THICKNESS USING CONCRETE MIX DESIGN LAID MANUALLY ALL AS SPECIFIED | CUM | 67 | ||
| 23 | SH1 | PROVIDING AND LAYING RCC 4000 PSI CONCRETE USING CRUSHED OR BROKEN STONE AS IN WALLS ROOF SLAB LANDING PLINTH BEAMS AND BAND ETC INCL FORM WORK REINFORCEMENT MEASURED AND PAID SEPARATELY | CUM | 1165 | ||
| 24 | SH1 | SUPPLY AND FIX STEEL REINFORCEMENT USING DEFORMED BAR GRADE-60 INCL CUTTING BINDING AND PLACING | KG | 8722 | ||
| 25 | SH1 | SUPPLY AND FIX BARS ROUND SQUARE OR FLAT INCLUDING CUTTING BENDING BINDING AND PLACING REINFORCEMENT IN POSITION | KG | 633 | ||
| 26 | SH1 | PROVIDING AND LAYING RCC PIPE 230MM BORE LAID AND JOINTED WITH SPIGOT SOCKET OR COLLAR COMPLETE | METRE | 2525 | ||
| 27 | SH1 | PROVIDING AND LAYING POLYETHYLENE PIPE (PE-100) 160MM DIA CLASS PN-10 / SDR-17 COMPLETE | METRE | 1001 | ||
| 28 | SH1 | PROVIDING AND LAYING UPVC 150MM BORE COMPLETE | METRE | 480 | ||
| 29 | SH1 | PROVIDING SAND CUSHION IN LAYER AS SPD UNDER CONCRETE ROAD, HARD STANDING AND RUNWAY ETC COMPLETE | CUM | 2958 | ||
| 30 | SH1 | PROVIDING AND LAYING BOND BREAKING MATERIALS USING 0.102 MM THICK POLYTHENE FILM OVER NORMAL THICKNESS OF CONCRETE FLOOR | SQM | 335 | ||
| 31 | SH1 | BURNT BRICK WORK IN WALL OVER 115MM THICK WALL LAID AND JOINTED IN CM 1:3 STRAIGHT OR CURVE WITH INNER RADIUS LESS THAN 6 MTR UPTO 4.25 MTR DEPTH COMPLETE | CUM | 777 | ||
| 32 | SH1 | PLASTER 1:4 13MM THICK FINISHED AS SPD (BASEMENT, GF, 1ST AND 2ND FLOOR) | SQM | 3397 | ||
| 33 | SH1 | PROVIDING AND APPLYING ONE COAT OF UNDILUTED WATER BASED ROAD / AIRFIELD MARKINGS PAINT (BERGER, STAR BRITE OR EQUIVALENT) WITH GLASS BEADS CONFORMING TO FEDERAL SPEC TT-B-1325C TYPE 1 GRADE A APPLIED AT 1 KG PER LITRE OF PAINT (FAA P-602) USING AIRLESS PNEUMATIC SPRAY MACHINE CAPABLE OF PAINTING UP TO 3 FEET WIDE STRIP WITH SYNCHRONIZED GLASS BEAD DISPENSING ATTACHMENT | SQM | 10011 | ||
| 34 | SH2 | CLEARING AND GRUBBING THE SITE INCLUDING REMOVAL OF GRASS, SHRUBS, BRUSHWOOD, UNDERGROWTH, ROOTS AND SMALL TREES NOT EXCEEDING 225 MM GIRTH, AND DISPOSING OF CLEARED MATERIAL OFF-SITE, COMPLETE AS SPECIFIED. | SQM | 7352 | ||
| 35 | SH2 | COMPACTION OF NATURAL GROUND UP TO 95% MODIFIED AASHTO DENSITY, INCLUDING SCARIFYING, WATERING AND ROLLING, COMPLETE AS SPECIFIED. | SQM | 7352 | ||
| 36 | SH2 | EXCAVATION IN ORDINARY SOIL UP TO 1.5 M DEPTH, IN FOUNDATIONS AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M; TIMBERING TO BE PAID EXTRA. | CUM | 2290 | ||
| 37 | SH2 | MAKING EMBANKMENT WITH SPECIFIED/APPROVED SOIL OBTAINED FROM BORROW EXCAVATION, INCLUDING LOADING WITHIN 5 KM, COMPACTION IN 150 MM LAYERS UP TO 95% MODIFIED AASHTO DENSITY, AND DRESSING TO REQUIRED PROFILE AND SHAPE. | CUM | 11028 | ||
| 38 | SH2 | GRANULAR FILLING UNDER FOOTING/FOUNDATION USING SPECIFIED/APPROVED GRANULAR MATERIAL, INCLUDING LOADING AND TRANSPORTATION WITHIN 5 KM, COMPACTION IN 150 MM LAYERS UP TO 95% MODIFIED AASHTO DENSITY, AND DRESSING TO REQUIRED PROFILE AND SHAPE. | CUM | 1103 | ||
| 39 | SH2 | PROVIDING AND LAYING AGGREGATE BASE COURSE OF ANY THICKNESS, LAID AND COMPACTED TO 100% MODIFIED AASHTO DENSITY USING APPROPRIATE COMPACTION EQUIPMENT AND ROLLER, COMPLETE AS SPECIFIED. | CUM | 1103 | ||
| 40 | SH2 | PROVIDING AND APPLYING PRIME COAT ON PREPARED AGGREGATE BASE COURSE SURFACE USING APPROVED BITUMINOUS MATERIAL AT THE SPECIFIED RATE, COMPLETE AS SPECIFIED. | SQM | 7352 | ||
| 41 | SH2 | PROVIDING AND LAYING PLANT-MIXED ASPHALTIC WEARING COURSE OF ANY THICKNESS USING ASPHALT CEMENT GRADE 60/70 OR 80/100 AND APPROVED JOB MIX FORMULA (JMF), INCLUDING HAULING, PLACING AND COMPACTION, EXCLUDING TACK COAT. | TON | 368 | ||
| 42 | SH2 | PROVIDING AND LAYING LEAN CONCRETE (PCC 1:4:8) USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED, FOR DRAIN WORKS, COMPLETE. | CUM | 76 | ||
| 43 | SH2 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN DIFFERENT STRUCTURAL ELEMENTS (FOUNDATION ETC.) INCLUDING FORMWORK, FOR DRAIN WORKS; REINFORCEMENT MEASURED AND PAID SEPARATELY. | CUM | 762 | ||
| 44 | SH2 | PROVIDING AND LAYING LEAN CONCRETE (PCC 1:4:8) USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED, FOR CULVERT WORKS, COMPLETE. | CUM | 5 | ||
| 45 | SH2 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN DIFFERENT STRUCTURAL ELEMENTS (FOUNDATION ETC.) INCLUDING FORMWORK, FOR CULVERT WORKS; REINFORCEMENT MEASURED AND PAID SEPARATELY. | CUM | 14 | ||
| 46 | SH2 | SUPPLY AND FIXING RCC PIPES 600 MM BORE, LAID AND JOINTED WITH SPIGOT-SOCKET OR TONGUE-AND-GROOVE JOINT INCLUDING RUBBER RING, COMPLETE AS SPECIFIED. | MTR | 4 | ||
| 47 | SH2 | APPLYING THREE COATS OF APPROVED ROAD MARKING PAINT ON NEW OR OLD SURFACE USING MECHANICAL MEANS, COMPLETE AS SPECIFIED. | SQM | 666 | ||
| 48 | SH2 | PROVIDING AND LAYING ROAD MARKING WITH REFLECTIVE THERMOPLASTIC (TP) PAINT FOR LINES OF 12.50 CM WIDTH (YELLOW). RATE BUILT FROM SOR COMPONENTS: 15-75 (PRIMER/PREP), 15-76 (TP APPLICATION), 15-77 (GLASS BEADS). | SQM | 822 | ||
| 49 | SH2 | PROVIDING AND LAYING ROAD MARKING WITH REFLECTIVE THERMOPLASTIC (TP) PAINT FOR LINES OF 12.50 CM WIDTH (WHITE). RATE BUILT FROM SOR COMPONENTS: 15-75 (PRIMER/PREP), 15-76 (TP APPLICATION), 15-77 (GLASS BEADS). | SQM | 11605 | ||
| 50 | SH2 | PROVIDING AND LAYING ROAD MARKING WITH REFLECTIVE THERMOPLASTIC (TP) PAINT FOR 4-METRE ARROWS. RATE BUILT FROM SOR COMPONENTS: 15-75 (PRIMER/PREP), 15-76 (TP APPLICATION), 15-77 (GLASS BEADS). | SQM | 881 | ||
| 51 | SH2 | PROVIDING AND FIXING ROAD SIGN BOARDS (E.G., CAUTION SIGNS) WITH REFLECTIVE PAINT, HAVING SUPERFICIAL AREA OF 1.125 SQM, INCLUDING COST OF POST, FOUNDATION, FIXING AND ALL ACCESSORIES, AS APPROVED BY THE ENGINEER, COMPLETE AS SPECIFIED. | NOS | 20 | ||
| 52 | SH3 | EXCAVATION IN ORDINARY SOIL UP TO 1.5 M DEPTH, IN FOUNDATION AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M; TIMBERING TO BE PAID EXTRA, COMPLETE AS SPECIFIED. | CUM | 1774 | ||
| 53 | SH3 | EXCAVATION IN HARD SOIL UP TO 1.5 M DEPTH, IN FOUNDATION AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M, INCLUDING BACKFILLING, COMPLETE AS SPECIFIED. | CUM | 612 | ||
| 54 | SH3 | EXCAVATION OVER AREAS IN ORDINARY/HARD SOIL FROM 1.5 M TO 3 M DEPTH, IN FOUNDATION/EXCAVATIONS, THROWING EARTH CLEAR WITHIN 50 M, COMPLETE AS SPECIFIED. | CUM | 157 | ||
| 55 | SH3 | EXCAVATION OVER AREAS IN ORDINARY/HARD SOIL UP TO 1.5 M DEPTH, IN FOUNDATION/EXCAVATIONS, THROWING EARTH CLEAR WITHIN 50 M, COMPLETE AS SPECIFIED. | CUM | 1787 | ||
| 56 | SH3 | BOTTOMING/SUB-BASE OF ANY THICKNESS USING GRANULAR SUB-BASE MATERIAL/SOIL AGGREGATES CBR 30%, LAID AND COMPACTED TO 100% MODIFIED AASHTO DENSITY, COMPLETE AS SPECIFIED. | CUM | 910 | ||
| 57 | SH3 | EARTH FILLING IN ORDINARY OR HARD SOIL, IN FOUNDATION, PIPE TRENCHES, SHAFTS, WELLS, INDEPENDENT HOLES, UNDER FLOORS OR AROUND PLINTH ETC., 1.5 M BELOW OR ABOVE GROUND LEVEL, WITH SPOIL OBTAINED FROM EXCAVATION, INCLUDING WATERING AND COMPACTION IN 150 MM LAYERS, COMPLETE AS SPECIFIED. | CUM | 894 | ||
| 58 | SH3 | PROVIDING AND LAYING LEAN CONCRETE (PCC 1:4:8) USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED, UNDER FOOTINGS/FOUNDATIONS, COMPLETE. | CUM | 310 | ||
| 59 | SH3 | PROVIDING AND LAYING SAND CUSHION UNDER FLOOR (100 MM THICK), COMPLETE AS SPECIFIED. | CUM | 1655 | ||
| 60 | SH3 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN DIFFERENT STRUCTURAL ELEMENTS (FOUNDATION ETC.) INCLUDING FORMWORK; REINFORCEMENT MEASURED AND PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 483 | ||
| 61 | SH3 | PROVIDING AND LAYING RCC WITH 4000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN FOUNDATIONS ETC., INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 188 | ||
| 62 | SH3 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN COLUMNS, BEAMS, STAIRS, POSTS, STRUTS, PIERS, LINTELS AND THE LIKE, INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 306 | ||
| 63 | SH3 | PROVIDING AND LAYING RCC WITH 4000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN COLUMNS, BEAMS, STAIRS, POSTS, STRUTS, PIERS, LINTELS, INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 105 | ||
| 64 | SH3 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ROOF SLABS, LANDINGS, WALLS, PLINTH BEAMS AND BANDS ETC., INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 618 | ||
| 65 | SH3 | PROVIDING AND LAYING RCC WITH 4000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ROOF SLABS, LANDINGS, WALLS, PLINTH BEAMS AND BANDS, INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY, COMPLETE AS SPECIFIED. | CUM | 430 | ||
| 66 | SH3 | PROVIDING AND LAYING PCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ALL NON-STRUCTURAL ELEMENTS, INCLUDING FORMWORK AND FAIR FACES TO EXPOSED SURFACES, COMPLETE AS SPECIFIED. | CUM | 12 | ||
| 67 | SH3 | PROVIDING AND LAYING PCC 1:2:4 IN FLOOR SLABS AS UNDERLAYER FOR TERRAZZO/TILES TOP FINISH, USING CRUSHED OR BROKEN STONE, COMPLETE AS SPECIFIED. | CUM | 194 | ||
| 68 | SH3 | PROVIDING AND LAYING PCC 1:3:6 IN FLOOR SLABS AS UNDERLAYER FOR TERRAZZO/TILES TOP FINISH, COMPLETE AS SPECIFIED. | CUM | 95 | ||
| 69 | SH3 | PROVIDING AND LAYING PCC 1:6:12 UNDER FLOORS USING CRUSHED OR BROKEN STONES, COMPLETE AS SPECIFIED. | CUM | 319 | ||
| 70 | SH3 | PROVIDING AND LAYING PCC 1:4:8 UNDER FLOOR USING CRUSHED OR BROKEN STONES, COMPLETE AS SPECIFIED. | CUM | 77 | ||
| 71 | SH3 | PROVIDING AND LAYING 50 MM THICK PCC 1:2:4 USING 3 MM AGGREGATE, FINISHED SMOOTH WITH STEEL FLOAT, COVERED WITH TWO COATS OF HOT BITUMEN AT 0.75 KG PER SQM EACH, AND BLINDED WITH 0.012 CUM OF SAND PER SQM. | SQM | 47 | ||
| 72 | SH3 | ADDITIONAL LABOUR FOR HOISTING/LOWERING CONCRETE FOR EACH STOREY BEYOND 12 M ABOVE/BELOW GL. | CUM | 222 | ||
| 73 | SH3 | PROVIDING, CUTTING, BENDING, PLACING AND BINDING HIGH TENSILE (GRADE-60) DEFORMED STEEL BAR REINFORCEMENT, COMPLETE. | KG | 290478 | ||
| 74 | SH3 | BURNT BRICK WORK IN WALL OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:6, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO 4.25 M DEPTH, COMPLETE AS SPECIFIED. | CUM | 118 | ||
| 75 | SH3 | BURNT BRICK WORK IN WALLS 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:4, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO GROUND FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 78 | ||
| 76 | SH3 | BURNT BRICK WORK IN WALL OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:6, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO GROUND FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 151 | ||
| 77 | SH3 | BURNT BRICK WORK IN WALL OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:6, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO FIRST FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 4 | ||
| 78 | SH3 | BURNT BRICK WORK IN WALL 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:4, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO FIRST FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 312 | ||
| 79 | SH3 | EXTRA TO BRICK FOR FORMING CAVITY, 57 MM WIDE, LAID AND JOINTED IN CEMENT MORTAR 1:3, ONE FACE MEASURED (CAVITY WALL), COMPLETE AS SPECIFIED. | SQM | 224 | ||
| 80 | SH3 | SUPPLY AND FIXING STEEL CHOWKAT, PRESS-MOULDED 18 SWG, FOR 115 MM WALLS, SINGLE LEAF, INCLUDING HOLDFAST, TIES FOR LATERAL MOVEMENT, PCC 1:2:4 CAVITY FILLING, ONE COAT ANTI-CREOSOTE PAINT (INTERNAL) AND RED OXIDE PAINT (EXTERNAL), COMPLETE AS SPECIFIED. | MTR | 1591 | ||
| 81 | SH3 | SUPPLY AND FIXING STEEL CHOWKAT, PRESS-MOULDED 18 SWG, FOR 230 MM WALLS, SINGLE/DOUBLE LEAF, INCLUDING HOLDFAST, TIES FOR LATERAL MOVEMENT, PCC 1:2:4 CAVITY FILLING, ONE COAT ANTI-CREOSOTE PAINT (INTERNAL) AND RED OXIDE PAINT (EXTERNAL), COMPLETE AS SPECIFIED. | MTR | 1075 | ||
| 82 | SH3 | SUPPLY AND FIXING WATERPROOF BUILDING/INSULATING PAPER WEIGHING 3.92 KG PER 10 SQM, FIXED ANY POSITION WITH 50 MM SIDE AND 150 MM END LAPS, COMPLETE AS SPECIFIED. | SQM | 1238 | ||
| 83 | SH3 | PROVIDING AND LAYING BOND-BREAKING SLIP MEMBRANE USING 0.102 MM THICK POLYETHYLENE FILM OVER NORMAL THICKNESS OF CONCRETE FLOOR, COMPLETE AS SPECIFIED. | SQM | 18 | ||
| 84 | SH3 | PROVIDING AND APPLYING TWO COATS OF HOT BITUMEN AT 0.75 KG PER SQM PER COAT, BLINDED WITH SAND AT 0.012 CUM PER SQM, COMPLETE AS SPECIFIED. | SQM | 130 | ||
| 85 | SH3 | SUPPLY AND FIXING SYNTHETIC VINYL (PVC) FLEXIBLE MEMBRANE 0.50 MM THICK WITH 75-100 MM SIDE/END LAPS, SEAMED/WELDED THERMALLY/CHEMICALLY (SUNK PORTION), COMPLETE AS SPECIFIED. | SQM | 137 | ||
| 86 | SH3 | SUPPLY AND FIXING DOUBLE LAYER OF WATERPROOFING BUILDING/INSULATING PAPER 3.92 KG PER 10 SQM FIXED ANY POSITION WITH 50 MM SIDE AND 150 MM END LAPS AND NAILING, COMPLETE AS SPECIFIED. | SQM | 7 | ||
| 87 | SH3 | SUPPLY AND FIXING DOUBLE LAYER OF WATERPROOFING BUILDING/INSULATING PAPER WITHOUT NAILING, INCLUDING 13 MM THICK CEMENT PLASTER CM 1:4, COMPLETE AS SPECIFIED. | SQM | 36 | ||
| 88 | SH3 | SUPPLY AND APPLYING ROOF INSULATION/WATERPROOFING USING DOUBLE LAYER OF BITUMEN FELT MEMBRANE (16-18 KG PER 10 SQM) WITH 50 MM SIDE AND 150 MM END LAPS, INCLUDING PRIMER AND STICKING COAT, COMPLETE AS SPECIFIED. | SQM | 1408 | ||
| 89 | SH3 | SUPPLY AND FIXING POLY EXTRUDED BOARD 50 MM THICK, DENSITY 32-35 KG/CUM, AS ROOF INSULATION WITH SHIP-LAP EDGES, ANY SIZE OF SHEET, ALL AS SPECIFIED. | SQM | 188 | ||
| 90 | SH3 | PROVIDING AND LAYING 50 MM THICK SCREED BED ON BOND-BREAKING MATERIAL, INCLUDING TWO COATS OF ELASTOMERIC CEMENTITIOUS WATERPROOFING COATING, COMPLETE AS SPECIFIED. | SQM | 111 | ||
| 91 | SH3 | PROVIDING AND LAYING SINGLE LAYER OF POLYESTER-BASED ROOFING BITUMEN FELT, INCLUDING PRIMER AND STICKING COAT, FOLLOWED BY A DOUBLE-LAYER FELT MEMBRANE, COMPLETE AS SPECIFIED. | SQM | 365 | ||
| 92 | SH3 | PROVIDING AND LAYING 50 MM THICK SCREED BED, 20 MM THICK TERRAZZO FLOOR USING MARBLE CHIPS (1:2), INCLUDING CUTTING, RUBBING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 367 | ||
| 93 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:3 MIX) ON WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 3930 | ||
| 94 | SH3 | PROVIDING AND APPLYING 19 MM THICK CEMENT-SAND PLASTER (1:3 MIX) ON WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 88 | ||
| 95 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:4 MIX) ON WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 5740 | ||
| 96 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:6 MIX) ON WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 6264 | ||
| 97 | SH3 | APPLYING THREE COATS OF PLASTIC EMULSION PAINT ON WALLS AND CEILING, COMPLETE AS SPECIFIED. | SQM | 3437 | ||
| 98 | SH3 | APPLYING THREE COATS OF WEATHER-SHIELD PAINT ON EXTERIOR SURFACES (NEW), COMPLETE AS SPECIFIED. | SQM | 1351 | ||
| 99 | SH3 | APPLYING THREE COATS OF WHITE WASH ON CEILING, COMPLETE AS SPECIFIED. | SQM | 1945 | ||
| 100 | SH3 | APPLYING THREE COATS OF DISTEMPER ON WALLS, COMPLETE AS SPECIFIED. | SQM | 5844 | ||
| 101 | SH3 | PROVIDING AND APPLYING TWO COATS OF WATERPROOFING COMPOUND USING BITUMEN 10/20 APPLIED HOT AT 4.90 KG PER 10 SQM, COMPLETE AS SPECIFIED. | SQM | 129 | ||
| 102 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT PLASTER 1:4 INCLUDING DECORATIVE PLASTER (EXTERNAL) FINISH, COMPLETE AS SPECIFIED. | SQM | 479 | ||
| 103 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT PLASTER 1:4 WITH PUDLO OR OTHER SIMILAR APPROVED WATERPROOFING MATERIAL MIXED WITH CEMENT AT 3% BY WEIGHT, COMPLETE AS SPECIFIED. | SQM | 26 | ||
| 104 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT PLASTER 1:4, INCLUDING ONE COAT OF HOT BITUMEN AT 0.75 KG PER SQM AND BLINDING WITH SAND AT 0.012 CUM PER SQM (BELOW GROUND LEVEL), COMPLETE AS SPECIFIED. | SQM | 208 | ||
| 105 | SH3 | PROVIDING AND APPLYING 13 MM THICK CEMENT PLASTER 1:4, INCLUDING THREE COATS OF CEMENT SLURRY WASH ON NEW/OLD SURFACE, COMPLETE AS SPECIFIED. | SQM | 19 | ||
| 106 | SH3 | FORMING V-GROOVES 13 MM WIDE AND 10 MM DEEP IN NEW PLASTER, COMPLETE AS SPECIFIED. | MTR | 139 | ||
| 107 | SH3 | FORMING V-GROOVES 25 MM WIDE AND 10 MM DEEP IN NEW PLASTER, COMPLETE AS SPECIFIED. | MTR | 427 | ||
| 108 | SH3 | FORMING V-GROOVES 25 MM WIDE AND 10 MM DEEP IN NEW PLASTER, INCLUDING SUPPLY AND FIXING ALUMINIUM COVER STRIP 60 MM WIDE X 2 MM THICK WITH ALL FITTINGS FOR ALL JOINTS, COMPLETE AS SPECIFIED. | MTR | 149 | ||
| 109 | SH3 | PROVIDING AND LAYING PLINTH PROTECTION 3 FEET WIDE, 3 INCH THICK PCC 1:2:4, INCLUDING EDGE WALL, PCC BLOCK, AND MARBLE PATTY, USING SULPHATE-RESISTANT CEMENT (SRC), COMPLETE AS SPECIFIED. | SQM | 1460 | ||
| 110 | SH3 | PROVIDING AND LAYING 50 MM THICK SCREED BED ON BOND-BREAKING MATERIAL, COMPLETE AS SPECIFIED. | SQM | 139 | ||
| 111 | SH3 | PROVIDING AND LAYING STANDARD QUALITY TILES OF ANY MAKE EXCEEDING 1600 SQ CM ON WALLS AND FLOORS, INCLUDING SETTING, JOINTING AND BONDING, COMPLETE AS SPECIFIED. | SQM | 243 | ||
| 112 | SH3 | PROVIDING AND LAYING STANDARD QUALITY MARBLE TILES (VARIOUS COLOURS) OF ANY SIZE, 20 MM THICK, INCLUDING SETTING, JOINTING, BONDING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 233 | ||
| 113 | SH3 | PROVIDING AND LAYING STANDARD QUALITY MARBLE TILES (VARIOUS COLOURS) OF ANY SIZE, 13 MM THICK, INCLUDING SETTING, JOINTING, BONDING AND CHEMICAL POLISHING (SKIRTING), COMPLETE AS SPECIFIED. | SQM | 41 | ||
| 114 | SH3 | PROVIDING AND LAYING 13 MM THICK TERRAZZO IN DADO/SKIRTING USING MARBLE CHIPS (1:2), INCLUDING 10 MM CEMENT PLASTER 1:3, CUTTING, RUBBING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 460 | ||
| 115 | SH3 | PROVIDING AND LAYING 20 MM THICK TERRAZZO FLOOR USING MARBLE CHIPS (1:2), INCLUDING CUTTING, RUBBING, CLEANING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 2811 | ||
| 116 | SH3 | PROVIDING AND LAYING 13 MM THICK STONOLITHIC 150 MM DADO/SKIRTING, INCLUDING 10 MM CEMENT PLASTER CM 1:4 AND TUCKING IN TOP EDGE, COMPLETE AS SPECIFIED. | SQM | 25 | ||
| 117 | SH3 | PROVIDING AND LAYING 20 MM THICK STONOLITHIC LAYER SPREAD OVER ORDINARY CONCRETE FLOORS, INCLUDING MARBLE PATTY AND RUBBING, COMPLETE AS SPECIFIED. | SQM | 213 | ||
| 118 | SH3 | PROVIDING AND LAYING 19 MM THICK TERRAZZO FLOOR, MARBLE CHIPS 1:2 MIXED WITH ORDINARY CEMENT, EXCLUDING CUTTING, RUBBING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 518 | ||
| 119 | SH3 | SUPPLY AND FIXING 8-10 MM THICK AND 40 MM WIDE MARBLE PATTY AS DIVIDING STRIPS IN FLOORS, COMPLETE AS SPECIFIED. | MTR | 3284 | ||
| 120 | SH3 | SUPPLY AND FIXING 25 MM THICK MARBLE SLAB AROUND VANITY BOWL WITH BRACKETS, INCLUDING CUTTING, RUBBING, POLISHING AND WATERTIGHT JOINTS, COMPLETE AS SPECIFIED. | SQM | 15 | ||
| 121 | SH3 | SUPPLY AND FIXING GYPSUM CEILING TILES 600 MM X 600 MM X 7.5 MM THICK, INCLUDING ALUMINIUM TEE/ANGLE FRAMING, HANGER CLIPS, JOINTING CLIPS AND GI WIRE, COMPLETE AS SPECIFIED. | SQM | 69 | ||
| 122 | SH3 | SUPPLY AND FIXING 13 MM THICK SOFT BOARD SHEET IN CAVITIES, COMPLETE AS SPECIFIED. | SQM | 7 | ||
| 123 | SH3 | APPLYING PRIMER COAT ON NEW WOOD WORK SUCH AS TIMBER WORK IN CEILING AND TIMBER BOARDING, COMPLETE AS SPECIFIED. | SQM | 33 | ||
| 124 | SH3 | SUPPLY AND FIXING 1ST CLASS SOFT WOOD (DEODAR) FRAMED AND PANELLED DOORS, PANELS FILLED WITH MDF 16 MM SHEET (EXCEPT CHOWKATS), INCLUDING HOLDFAST, MONGERY AND THREE COATS SYNTHETIC ENAMEL PAINT, 38 MM THICK, COMPLETE AS SPECIFIED. | SQM | 206 | ||
| 125 | SH3 | SUPPLY AND FIXING 1ST CLASS SOFT WOOD (DEODAR) GLAZED DOORS WITH MOULDED/CHAMFERED BARS, PANELS FILLED WITH GLASS, HOLDFASTS, HINGES/PIVOTS, MONGERY AND THREE COATS SYNTHETIC ENAMEL PAINT (EXCEPT CHOWKATS), 38 MM THICK, COMPLETE AS SPECIFIED. | SQM | 47 | ||
| 126 | SH3 | SUPPLY AND FIXING 38 MM FIRST CLASS SOFT WOOD (DEODAR) GLAZED DOOR, 9X9 MESH 24 GAUGE, EXCLUDING CHOWKATS, HOLDFASTS, HINGES/PIVOTS, MONGERY, WITH THREE COATS SYNTHETIC ENAMEL PAINT, COMPLETE AS SPECIFIED. | SQM | 6 | ||
| 127 | SH3 | SUPPLY AND FIXING 38 MM THICK FIRST CLASS SOFT WOOD HOLLOW FLUSH DOOR, INCLUDING 3 MM THICK TEAK PLY BOTH SIDES AND BRASS CP MONGERY, EXCEPT CHOWKAT, KICK PLATES AND BOW HANDLES, COMPLETE AS SPECIFIED. | SQM | 43 | ||
| 128 | SH3 | SUPPLY AND FIXING 38 MM THICK 1ST CLASS SOFT WOOD (DEODAR) FRAMED AND PANELLED DOORS, PANELS FILLED WITH MDF 16 MM SHEET, INCLUDING 2X2 ARCHITRAVE WITH ALL FITTINGS, CHOWKAT AND THREE COATS SYNTHETIC ENAMEL PAINT (LOCKERS), COMPLETE AS SPECIFIED. | SQM | 77 | ||
| 129 | SH3 | SUPPLY AND FIXING 1ST CLASS SOFT WOOD (DEODAR) GAUZED DOORS, 9X9 MESH 24 GAUGE, 38 MM THICK, WITHOUT CHOWKATS, INCLUDING THREE COATS SYNTHETIC ENAMEL PAINT, COMPLETE AS SPECIFIED. | SQM | 22 | ||
| 130 | SH3 | SUPPLY AND FIXING 38 MM THICK 1ST CLASS SOFT WOOD GAUZE DOORS, GATES ETC., EXCEPT CHOWKATS, INCLUDING CP IRON MONGERY AND THREE COATS SYNTHETIC ENAMEL PAINT, COMPLETE AS SPECIFIED. | SQM | 3 | ||
| 131 | SH3 | SUPPLY AND FIXING TUBULAR PARTICLE BOARD ENGINEERED DOOR 38 MM THICK, INCLUDING MONGERY, DOLLY FRAME CHOWKATS 2X2 ALL AROUND, AND TWO COATS SYNTHETIC ENAMEL PAINT, COMPLETE AS SPECIFIED. | SQM | 60 | ||
| 132 | SH3 | SUPPLY AND FIXING BOX-PIPE TYPE OPENABLE AND FIXED SIDE-HUNG WINDOW OR CSW USING 16 GAUGE FRAME 50X25 MM, PANEL Z 38X31X38 MM, 10X10 MM SQUARE GOLA, NOT EXCEEDING 1.48 SQM EACH, WITH FITTINGS/MONGERY, HOLDFAST, TWO COATS SYNTHETIC ENAMEL PLUS PRIMER, INCLUDING 5 MM PLAIN SHEET GLASS, COMPLETE AS SPECIFIED. | SQM | 254 | ||
| 133 | SH3 | SUPPLY AND FIXING UPVC SLIDING WINDOW, 37 MM THICK SHUTTER WITH FRAME 80X50 MM, EXCEEDING 2.23 SQM EACH, WHITE, WITH FITTINGS, MONGERY, FLY-PROOF NETTING, INCLUDING 5 MM TINTED SHEET GLASS, COMPLETE AS SPECIFIED. | SQM | 175 | ||
| 134 | SH3 | SUPPLY AND FIXING UPVC SLIDING WINDOW, DOUBLE GLAZED 5 MM TINTED GLASS, 37 MM THICK SHUTTER WITH FRAME 80X50 MM, EXCEEDING 2.23 SQM EACH, COMPLETE AS SPECIFIED. | SQM | 29 | ||
| 135 | SH3 | SUPPLY AND FIXING UPVC OPENABLE WINDOW, 60 MM THICK SHUTTER WITH FRAME, DOUBLE GLAZING 5 MM TINTED GLASS, EXCEEDING 2.23 SQM EACH, COMPLETE AS SPECIFIED. | SQM | 6 | ||
| 136 | SH3 | SUPPLY AND FIXING 1.6 MM ALUMINIUM SLIDING WINDOW, DELUXE QUALITY, WOOD-LOOK COLOUR EXTRUDED SECTION, INCLUDING 5 MM THICK GLASS, COMPLETE AS SPECIFIED. | SQM | 45 | ||
| 137 | SH3 | SUPPLY AND FIXING BOX TYPE STEEL SLIDING/FIXED WINDOW OR CSW, 16 GAUGE FRAME 75X30 MM, PANEL 25X50 MM GOLA, INCLUDING FITTINGS, MONGERY, HOLDFAST, SYNTHETIC ENAMEL PAINT, PRIMER, GLASS PANES, GRILL AND WIRE GAUZE, COMPLETE AS SPECIFIED. | SQM | 26 | ||
| 138 | SH3 | SUPPLY AND FIXING ALUMINIUM TINNED WIRE GAUZE, 16X16 MESH, 26 GAUGE, FIXED WITH FLAT IRON 13X3 MM TO STEEL WINDOW FRAMES WITH SCREWS 75 MM OLC, COMPLETE AS SPECIFIED. | SQM | 134 | ||
| 139 | SH3 | SUPPLY AND FIXING ALUMINIUM FLY/INSECT SCREENING WITH MESH (PREMIUM MODEL), ANODIZED EXTRUDED SECTION, INCLUDING FIXING ON CONCRETE/WOOD/STEEL FRAMES, COMPLETE AS SPECIFIED. | SQM | 25 | ||
| 140 | SH3 | SUPPLY AND FIXING UPVC DOOR, 60 MM THICK SHUTTER, GROOVE PANEL 20 MM THICK, FILLED AS PER FIG 07-2 SKETCH 7-2.4 INSTEAD OF GLASS, COMPLETE, EXCEEDING 1.9 SQM EACH, WHITE, WITH FITTINGS, MONGERY AND FLY-PROOF NETTING, COMPLETE AS SPECIFIED. | SQM | 170 | ||
| 141 | SH3 | SUPPLY AND FIXING UPVC OPENABLE DOOR, 60 MM THICK SHUTTER WITH FRAME, EXCEEDING 2.23 SQM EACH, WHITE, WITH FITTINGS, MONGERY, AND PLASTIC WIRE GAUZE MOSQUITO PROOF 18X18 MESH 28 GAUGE (FOR GAUZE DOOR), COMPLETE AS SPECIFIED. | SQM | 18 | ||
| 142 | SH3 | SUPPLY AND FIXING GUARD BARS, GRILLS, RAILINGS, LADDERS, BRACKETS, HOOKS, HOLDFASTS AND FRAMES ETC., CUT TO DEAD LENGTH, REDUCED TO SIZE/SHAPE, FIGURE ETC. INCLUDING PUNCHING / DRILLING HOLES IF NECESSARY AND FIXING, ASSEMBLING BY WELDING OR BOLTS/NUTS/RIVETS/WASHERS ETC. AND ERECTION / FIXING IN POSITION INCLUDING MAKING GOOD DISTURBED SURFACES, COMPLETE AS SPECIFIED. | SQM | 35260 | ||
| 143 | SH3 | SUPPLY AND FIXING CP LOCK OR LATCH, 150 MM DELUXE, TWO BOLTS, TWO LEVERS, COMPLETE. | EACH | 10 | ||
| 144 | SH3 | SUPPLY AND FIXING RIM LOCK/LATCH CP BEST QUALITY, TWO KEYS, TWO LEVERS, COMPLETE. | EACH | 19 | ||
| 145 | SH3 | SUPPLY AND FIXING DOOR CLOSER (DELUXE), ANODIZED BRONZE, COMPLETE. | NO | 14 | ||
| 146 | SH3 | SUPPLY AND FIXING ALUMINIUM DOOR CLOSER (PREMIUM), ANODIZED BRONZE, COMPLETE. | EACH | 10 | ||
| 147 | SH3 | SUPPLY AND FIXING UPVC DOOR LOCK, COMPLETE. | NO | 19 | ||
| 148 | SH3 | SUPPLY AND FIXING UPVC DOOR HANDLE, COMPLETE. | NO | 47 | ||
| 149 | SH3 | SUPPLY AND FIXING 300 MM CP SLIDING/LOCKING BOLTS WITH STAPLE, COMPLETE. | EACH | 111 | ||
| 150 | SH3 | SUPPLY AND FIXING 150 MM HELICAL STEEL SPRING FOR DOORS, CP, COMPLETE. | EACH | 127 | ||
| 151 | SH3 | SUPPLY AND FIXING BRASS PEGS 125 MM OR OVER, COMPLETE. | EACH | 15 | ||
| 152 | SH3 | SUPPLY AND FIXING STAINLESS STEEL KICK PLATE (16-18G), COMPLETE. | SQM | 1 | ||
| 153 | SH3 | SUPPLY AND FIXING FILLETS (UP TO 12.90 SQ CM) 1ST CLASS SOFT WOOD, WROUGHT AND SCREWED, COMPLETE. | MTR | 101 | ||
| 154 | SH3 | SUPPLY AND FIXING 5 MM TINTED GLASS TO TIMBER/STEEL SASHES WITH BEADS OR RUBBER LINING, COMPLETE. | SQM | 48 | ||
| 155 | SH3 | SUPPLY AND FIXING GENERAL STEEL WORK (HOLDFASTS, FLAT IRON, WALL TIES) CUT TO LENGTH, DRILLED AND ERECTED, COMPLETE. | KG | 291 | ||
| 156 | SH3 | SUPPLY AND FIXING STAINLESS STEEL GRADE 304 HAND RAILING (3/4 INCH TO 2 INCH DIA, 16-18G PIPE), COMPLETE. | MTR | 108 | ||
| 157 | SH3 | SUPPLY AND FIXING 2 INCH X 2 INCH MS HOLLOW PIPE (16G), INCL WELDING AND PAINTING, COMPLETE. | MTR | 48 | ||
| 158 | SH3 | SUPPLY AND FIXING XPM (EXPANDED METAL) BRC WELD-MESH, INCL BINDING WIRE, COMPLETE. | SQM | 91 | ||
| 159 | SH3 | SUPPLY AND FIXING UPVC DUCT COVERS USING UPVC FILLETS 45 MM X 20 MM, COMPLETE. | SQM | 6 | ||
| 160 | SH3 | APPLYING TWO COATS WEATHER-RESISTANT PAINT ON EXTERIOR WALL (OLD), COMPLETE. | SQM | 857 | ||
| 161 | SH3 | APPLYING TWO COATS SYNTHETIC ENAMEL PAINT, COMPLETE. | SQM | 53 | ||
| 162 | SH3 | SUPPLY AND FIXING 5 MM SILVERED GLASS MIRROR, GROUND EDGES, COMPLETE. | SQM | 41 | ||
| 163 | SH3 | SUPPLY AND FIXING PLASTIC SHELF WITH PLUGS AND SCREWS, COMPLETE. | EACH | 31 | ||
| 164 | SH3 | SUPPLY AND FIXING CP TOWEL RAIL (SINGLE ROD), COMPLETE. | EACH | 53 | ||
| 165 | SH3 | SUPPLY AND FIXING SOAP/SPONGE TRAY WITH PLUGS AND SCREWS, COMPLETE. | EACH | 43 | ||
| 166 | SH3 | SUPPLY AND FIXING TOILET PAPER HOLDER, PAK MADE, COMPLETE. | EACH | 1 | ||
| 167 | SH3 | SUPPLY AND FIXING 6-PIECE BATH SET (PLASTIC), COMPLETE. | EACH | 2 | ||
| 168 | SH3 | SUPPLY AND FIXING 7-PIECE BATH SET (DELUXE, CP/YC), COMPLETE. | EACH | 12 | ||
| 169 | SH3 | SUPPLY AND FIXING VANITY BOWL (GLAZED), INCL BOTTLE TRAP, WASTE COUPLING, CP MIXER, COMPLETE. | EACH | 44 | ||
| 170 | SH3 | SUPPLY AND FIXING WHB (660X560 MM), INCL WASTE, COUPLING, PLUG, CP MIXER, COMPLETE. | EACH | 15 | ||
| 171 | SH3 | SUPPLY AND FIXING WHB WITH PEDESTAL (660X560 MM), INCL WASTE, CHAIN, PLUG, COMPLETE. | EACH | 2 | ||
| 172 | SH3 | SUPPLY AND FIXING WC (EUROPEAN COUPLED), DELUXE, COMPLETE. | EACH | 16 | ||
| 173 | SH3 | SUPPLY AND FIXING WC (ASIATIC, >550 MM) WITH FLUSHING SYSTEM, COMPLETE. | EACH | 55 | ||
| 174 | SH3 | SUPPLY AND FIXING URINAL BASIN (STALL PATTERN), INCL FLUSHING PIPE, COMPLETE. | EACH | 1 | ||
| 175 | SH3 | SUPPLY AND FIXING CP SHOWER ROSE (FIXED/ADJUSTABLE), COMPLETE. | EACH | 2 | ||
| 176 | SH3 | SUPPLY AND FIXING TOILET SHOWER, 100 MM DIA, COMPLETE. | EACH | 4 | ||
| 177 | SH3 | SUPPLY AND FIXING SINK MIXER, STANDARD, COMPLETE. | EACH | 4 | ||
| 178 | SH3 | SUPPLY AND FIXING STAINLESS STEEL SINK SCULLERY (SINGLE/DOUBLE BOWL), INCL CP MIXER, COMPLETE. | EACH | 3 | ||
| 179 | SH3 | SUPPLY AND FIXING KITCHEN FLOOR/SINK CABINET (600X862 MM), INCL MONGERY, MARBLE SLAB, COMPLETE. | SQM | 37 | ||
| 180 | SH3 | SUPPLY AND FIXING KITCHEN WALL CABINET (381X610 MM), INCL CP MONGERY, COMPLETE. | MTR | 33 | ||
| 181 | SH3 | SUPPLY AND FIXING KITCHEN EXHAUST HOOD (TEAK VENEER + PGI SHEET), COMPLETE. | MTR | 1 | ||
| 182 | SH3 | SUPPLY AND FIXING WARDROBE (BUILT-IN CABINET), INCL FRAME, SHUTTERS, MONGERY, COMPLETE. | SQM | 86 | ||
| 183 | SH3 | SUPPLY AND FIXING 50 MM PRECAST RCC JALI, INCL SETTING AND JOINTING, COMPLETE. | SQM | 5 | ||
| 184 | SH3 | CONSTRUCTION OF KHURRA (TOP ROOF OR GROUND), INCL PCC BASE AND BRICKWORK, COMPLETE. | NO | 7 | ||
| 185 | SH3 | CONSTRUCTION OF CHIMNEY STACK, INCL BRICKWORK, PLASTER, GI FLASHING, COMPLETE. | EACH | 6 | ||
| 186 | SH3 | PROVIDING EXPANSION JOINT (13 MM WIDE) WITH BITUMEN FILLER, COMPLETE. | JOB | 1 | ||
| 187 | SH3 | CONSTRUCTION OF GREASE TRAP (NOT EXCEEDING 600 MM DEEP), COMPLETE. | EACH | 11 | ||
| 188 | SH3 | PROVISION OF HEATER RECESS, INCL BRICKWORK, PLASTER, PCC, COMPLETE. | EACH | 6 | ||
| 189 | SH3 | SUPPLY AND FIXING CHULLAH HOOD, INCL MS FRAME, GI SHEET, PLASTER, COMPLETE. | EACH | 1 | ||
| 190 | SH3 | SUPPLY AND FIXING OF PROPRIETARY CLAY TANDOOR COMPLETE, INCLUDING ALL LABOR, MATERIALS, PLANT, SCAFFOLDING, AND TESTING, COMPRISING SUPPLY AND INSTALLATION OF THE PROPRIETARY CLAY TANDOOR UNIT WITH ITS INSULATED CLAY BODY AND LINING, MILD STEEL OR CAST IRON GRILL AND FRAME, ASH COLLECTION TRAY, CHIMNEY/FLUE CONNECTION, AND ALL NECESSARY ACCESSORIES, COMPLETE WITH FIXING IN POSITION, SEALING, AND FINISHING TO MAKE THE INSTALLATION FULLY FUNCTIONAL, STRICTLY IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, THE APPROVED DRAWING, AND ALL APPLICABLE LOCAL CODES AND STANDARDS, WITH THE CONTRACTOR RESPONSIBLE FOR ENSURING PROPER ALIGNMENT, LEVELING, AND SAFE TERMINATION OF THE FLUE, AND FOR DEMONSTRATING SATISFACTORY WORKING PERFORMANCE (INCLUDING PROPER DRAFT AND COMBUSTION) UPON COMPLETION, ALL TO THE ENTIRE SATISFACTION OF THE ENGINEER-IN-CHARGE. | EACH | 1 | ||
| 191 | SH3 | SEWERAGE HANG ARRANGEMENT, COMPLETE WITH U-TRAPEZE HANGER, EPOXY FILLING, CEMENTITIOUS GROUT, CORE CUT, COMPLETE. | JOB | 1 | ||
| 192 | SH3 | EXCAVATE, DISPOSE SPOIL, SUPPLY SURFACE GULLIES (230X230X100 MM) WITH 100 MM PCC SURROUND AND CI GRATING, COMPLETE. | EACH | 62 | ||
| 193 | SH3 | CONSTRUCTION OF MANHOLES, COMPLETE, NOT EXCEEDING 600 MM DEEP, BRICK WALLS, EXCEPT COVER, COMPLETE. | CUM | 78 | ||
| 194 | SH3 | CONSTRUCTION OF MANHOLES, COMPLETE, 600-1800 MM DEEP, WITH IRON STEPS, BRICK WALLS, EXCEPT COVER, COMPLETE. | CUM | 12 | ||
| 195 | SH3 | PROVIDING AND LAYING PRECAST RCC MANHOLE COVER WITH ANGLE IRON FRAME, COMPLETE. | EACH | 192 | ||
| 196 | SH3 | SUPPLY AND FIXING RCC PIPES 150 MM BORE, LAID AND JOINTED, COMPLETE. | MTR | 234 | ||
| 197 | SH3 | SUPPLY AND FIXING UPVC SOIL AND WASTE PIPE 50 MM DIA, WITH SOLVENT CEMENT JOINT, COMPLETE. | MTR | 155 | ||
| 198 | SH3 | SUPPLY AND FIXING UPVC SOIL AND WASTE PIPE 75 MM DIA, WITH SOLVENT CEMENT JOINT, COMPLETE. | MTR | 478 | ||
| 199 | SH3 | SUPPLY AND FIXING UPVC SOIL AND WASTE PIPE 110 MM DIA, WITH SOLVENT CEMENT JOINT, COMPLETE. | MTR | 530 | ||
| 200 | SH3 | SUPPLY AND FIXING UPVC SOIL AND WASTE PIPE 160 MM BORE, WITH SOLVENT CEMENT JOINT, COMPLETE. | MTR | 293 | ||
| 201 | SH3 | SUPPLY AND FIXING UPVC ELBOW/BEND 90 DEG 75 MM DIA, COMPLETE. | EACH | 71 | ||
| 202 | SH3 | SUPPLY AND FIXING UPVC ELBOW/BEND 90 DEG 110 MM DIA, COMPLETE. | EACH | 198 | ||
| 203 | SH3 | SUPPLY AND FIXING 75 MM DIA UPVC ELBOW/BENDS 90 DEG, COMPLETE. | EACH | 2 | ||
| 204 | SH3 | SUPPLY AND FIXING 110 MM DIA UPVC ELBOW/BENDS 90 DEG, COMPLETE. | EACH | 2 | ||
| 205 | SH3 | SUPPLY AND FIXING ECCENTRIC REDUCER 50 MM X 110 MM DIA, COMPLETE. | EACH | 69 | ||
| 206 | SH3 | SUPPLY AND FIXING UPVC EQUAL TEE 110 MM DIA, COMPLETE. | EACH | 82 | ||
| 207 | SH3 | SUPPLY AND FIXING UPVC ACCESS/DOOR TEE 110 MM DIA, COMPLETE. | EACH | 13 | ||
| 208 | SH3 | SUPPLY AND FIXING UPVC ACCESS/DOOR TEE 75 MM DIA, COMPLETE. | EACH | 4 | ||
| 209 | SH3 | SUPPLY AND FIXING UPVC REDUCER Y-TEE 75 MM X 110 MM DIA, COMPLETE. | EACH | 5 | ||
| 210 | SH3 | SUPPLY AND FIXING UPVC VENT COWL 50 MM DIA, COMPLETE. | EACH | 61 | ||
| 211 | SH3 | SUPPLY AND FIXING 100 MM DIA FLOOR TRAP WITH GRATING, COMPLETE. | EACH | 110 | ||
| 212 | SH3 | SUPPLY AND FIXING 150 MM DIA (MEDIUM) GI WATER PIPE WITH FITTINGS, COMPLETE. | MTR | 410 | ||
| 213 | SH3 | SUPPLY AND FIXING 200 MM DIA (4.8 MM THICK) GI WATER PIPE WITH FITTINGS, COMPLETE. | MTR | 57 | ||
| 214 | SH3 | SUPPLY AND FIXING 150 MM DIA SLUICE VALVE (BSS-3464), COMPLETE. | EACH | 2 | ||
| 215 | SH3 | SUPPLY AND FIXING 150 MM DIA MS/GI FLANGES, COMPLETE. | EACH | 4 | ||
| 216 | SH3 | SUPPLY AND INSTALLATION OF WATER GAUGE WITH FLOAT AND ACCESSORIES, COMPLETE. | EACH | 1 | ||
| 217 | SH3 | DESIGN, SUPPLY, FABRICATION, AND CONSTRUCTION OF A COMPLETE REINFORCED CEMENT CONCRETE (RCC) OVERHEAD WATER TANK ON BUILDING ROOF, INCLUDING ALL LABOR, MATERIALS, PLANT, SCAFFOLDING, AND TESTING, COMPRISING SURFACE PREPARATION OF THE EXISTING ROOF SLAB, RCC PEDESTALS AND COLUMNS WITH BRACING, RCC TANK BODY COMPRISING WALLS AND BED SLAB, RCC ROOF SLAB WITH MANHOLE COVER, COMPLETE MS ACCESS LADDER WITH ANCHOR CONNECTIONS, ALL INTERNAL PLUMBING (INLET, OUTLET, OVERFLOW, WASHOUT PIPES WITH VALVES, AND WATER LEVEL INDICATOR), COMPLETE MS RAILING, AND LIGHTNING ARRESTER WITH GROUNDING, STRICTLY ADHERING TO GRADE-60 DEFORMED STEEL, SPECIFIED CONCRETE MIXES, AND LOCAL SEISMIC AND WIND PARAMETERS, WITH PERFORMANCE PARAMETERS INCLUDING A STORAGE CAPACITY [>20,000 US GALLONS], FREEBOARD, ZERO-LEAKAGE WATERPROOFING, AND COMPLIANCE WITH ALL STRUCTURAL SAFETY AND SERVICEABILITY REQUIREMENTS AS PER BCP. | EACH | 15 | ||
| 218 | SH3 | ELECTRIC WELDING WORKS, COMPLETE AS PER SPECIFICATION. | MTR | 60 | ||
| 219 | SH4 | TAKING UP OR DOWN TILES/MARBLE/GRANITE WORK OF ANY TYPE LAID IN FLOORS/WALLS ETC., INCLUDING STACKING SERVICEABLE MATERIAL AND DISPOSING OF UN-SERVICEABLE MATERIAL, COMPLETE AS SPECIFIED. | SQM | 112 | ||
| 220 | SH4 | DISMANTLING SINGLE TILING OF BRICK OR PCC IN ROOF OR FLOOR, LAID IN CEMENT MORTAR, INCLUDING HALF BRICKS OR BLOCKS ON EDGE, IN ANY POSITION, INCLUDING DISPOSAL OF DEBRIS, COMPLETE AS SPECIFIED. | SQM | 139 | ||
| 221 | SH4 | DEMOLITION OF PLAIN CEMENT CONCRETE OF ANY THICKNESS, INCLUDING BREAKING, STACKING AND DISPOSAL OF DEBRIS, COMPLETE AS SPECIFIED. | CUM | 27 | ||
| 222 | SH4 | TAKING DOWN DOOR OR GATE LEAVES ONLY (SINGLE OR FOLDING) OF ANY PATTERN OR THICKNESS NOT EXCEEDING 2.60 M EACH, INCLUDING REMOVAL OF FITTINGS AND STACKING SERVICEABLE MATERIAL, COMPLETE AS SPECIFIED. | EACH | 18 | ||
| 223 | SH4 | REMOVING WHITE/COLOUR WASH, DISTEMPER, PLASTIC EMULSION PAINT AND WEATHER RESISTANT PAINT FROM PLASTERED/UN-PLASTERED SURFACES BY SCRAPING, SANDING OR CHEMICAL MEANS, INCLUDING CLEANING THE SURFACE, COMPLETE AS SPECIFIED. | SQM | 934 | ||
| 224 | SH4 | EXCAVATION IN ORDINARY SOIL UP TO 1.5 M DEPTH, IN FOUNDATIONS AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M; TIMBERING TO BE PAID EXTRA. | CUM | 15 | ||
| 225 | SH4 | SUPPLY AND FIXING RCC PIPES 230 MM BORE, LAID AND JOINTED WITH SPIGOT-SOCKET OR COLLARS, INCLUDING RUBBER RING, COMPLETE AS SPECIFIED. | MTR | 64 | ||
| 226 | SH4 | CONSTRUCTION OF BRICK MASONRY MANHOLE, RECTANGULAR OR CIRCULAR, EXCEEDING 600 MM DEEP BUT NOT EXCEEDING 1800 MM DEEP, WITH IRON STEPS AT 380 MM CENTRES, 230 MM THICK BRICK WALLS, EXCLUDING COVER, COMPLETE AS SPECIFIED. | CUM | 17 | ||
| 227 | SH4 | SUPPLY AND FIXING UPVC SOIL AND WASTE PIPE 110 MM DIAMETER, COMPLETE WITH Z-JOINT AND RUBBER RING, COMPLETE AS SPECIFIED. | MTR | 46 | ||
| 228 | SH4 | SUPPLY AND FIXING STEEL CHOWKAT, PRESS-MOULDED 18 SWG, FOR 115 MM WALLS, SINGLE LEAF, INCLUDING HOLDFAST, TIES FOR LATERAL MOVEMENT, PCC 1:2:4 CAVITY FILLING, ONE COAT ANTI-CREOSOTE PAINT (INTERNAL) AND RED OXIDE PAINT (EXTERNAL), COMPLETE AS SPECIFIED. | MTR | 26 | ||
| 229 | SH4 | PROVIDING AND APPLYING 19 MM THICK CEMENT-SAND PLASTER (1:4 MIX) ON INTERNAL WALL SURFACES (BASEMENT, GROUND, FIRST AND SECOND FLOORS), FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 139 | ||
| 230 | SH4 | PROVIDING AND LAYING 50 MM THICK SCREED BED ON BOND-BREAKING MATERIAL, COMPLETE AS SPECIFIED. | SQM | 139 | ||
| 231 | SH4 | PROVIDING AND LAYING STANDARD QUALITY TILES OF ANY MAKE NOT EXCEEDING 1600 SQ CM (16 INCH X 16 INCH), INCLUDING SETTING, JOINTING AND BONDING, COMPLETE AS SPECIFIED. | SQM | 185 | ||
| 232 | SH4 | SUPPLY AND FIXING GYPSUM CEILING TILES 600 MM X 600 MM X 7.5 MM THICK, INCLUDING ALUMINIUM TEE/ANGLE FRAMING, HANGER CLIPS, JOINTING CLIPS AND GI WIRE, COMPLETE AS SPECIFIED. | SQM | 142 | ||
| 233 | SH4 | APPLYING PRIMER COAT ON NEW WOOD WORK SUCH AS TIMBER WORK IN CEILING AND TIMBER BOARDING, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 33 | ||
| 234 | SH4 | SUPPLY AND FIXING 38 MM THICK 1ST CLASS SOFT WOOD (DEODAR) FRAMED AND PANELLED DOORS, INCLUDING CHOWKATS, HOLDFASTS, MONGERY AND TWO COATS OF SYNTHETIC ENAMEL PAINT, COMPLETE AS SPECIFIED. | SQM | 10 | ||
| 235 | SH4 | RE-SECURING WITHOUT TAKING DOWN DOOR CHOWKATS EXCEEDING 2.60 M EACH, INCLUDING ARCHITRAVES IF ANY, HARD/SOFT WOOD, INCLUDING ADJUSTMENT AND PLUGGING, COMPLETE AS SPECIFIED. | EACH | 18 | ||
| 236 | SH4 | SUPPLY AND FIXING ALUMINIUM SWING DOOR, SINGLE SHUTTER, DELUXE QUALITY, ANODIZED ALUMINIUM EXTRUDED SECTION, ANY SIZE/COLOUR/TEXTURE, FIXED ON CONCRETE/WOOD/STEEL FRAMES, COMPLETE EXCEPT GLASS, LOCK AND HANDLE. | SQM | 24 | ||
| 237 | SH4 | SUPPLY AND FIXING ALUMINIUM SLIDING WINDOW, PREMIUM QUALITY, ANODIZED ALUMINIUM EXTRUDED SECTION, ANY SIZE/COLOUR/TEXTURE, FIXED ON CONCRETE/WOOD/STEEL FRAMES, WITH ALL NECESSARY FITTINGS EXCEPT GLASS. | SQM | 25 | ||
| 238 | SH4 | SUPPLY AND FIXING 5 MM THICK TINTED GLASS, FIXED TO TIMBER OR STEEL SASHES WITH HARD/SOFTWOOD BEADS AND SCREWS OR RUBBER LINING, COMPLETE AS SPECIFIED. | SQM | 48 | ||
| 239 | SH4 | SUPPLY AND FIXING CP LOCK OR LATCH, 150 MM DELUXE QUALITY, WITH TWO BOLTS AND TWO LEVERS, IN ANY PATTERN/SHAPE, COMPLETE AS SPECIFIED. | EACH | 10 | ||
| 240 | SH4 | SUPPLY AND FIXING ALUMINIUM DOOR CLOSER, PREMIUM MODEL, ANODIZED BRONZE, COMPLETE AS SPECIFIED. | EACH | 10 | ||
| 241 | SH4 | APPLYING TWO COATS OF APPROVED WEATHER-RESISTANT EXTERIOR PAINT ON OLD PLASTERED EXTERIOR WALL SURFACES, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 857 | ||
| 242 | SH4 | SUPPLY AND FIXING WALL SHOWER SET SINGLE LEVER CP (STANDARD), CONSISTING OF WALL SHOWER, DOUBLE BIB COCK, TEE STOP COCK, BASIN MIXER AND TOILET SHOWER, COMPLETE AS SPECIFIED. | EACH | 1 | ||
| 243 | SH4 | SUPPLY AND FIXING TOILET SHOWER, 15 MM DIAMETER, COMPLETE AS SPECIFIED. | EACH | 2 | ||
| 244 | SH4 | SUPPLY AND FIXING VANITY BOWL, GLAZED WARE, ONE HOLE, WITH BOTTLE TRAP AND WASTE COUPLING, COMPLETE AS SPECIFIED (EXCLUDING MIXER). | EACH | 2 | ||
| 245 | SH4 | SUPPLY AND FIXING WATER CLOSET (WC) OF DELUXE QUALITY, EUROPEAN PATTERN, COMPLETE (COUPLED), COMPLETE AS SPECIFIED. | EACH | 2 | ||
| 246 | SH4 | SUPPLY AND FIXING BATH ACCESSORIES SET (PLASTIC) CONSISTING OF SHELF, TOWEL RAIL, RING, BRUSH HOLDER, TOILET PAPER HOLDER, SOAP DISH AND MIRROR, COMPLETE AS SPECIFIED. | EACH | 2 | ||
| 247 | SH4 | PROVIDING AND LAYING PRECAST RCC 1:2:4 MANHOLE COVER WITH EMBEDDED ANGLE-IRON FRAME, AS PER INFORMATION SHEET SVCS-341, COMPLETE AS SPECIFIED. | NOS | 15 | ||
| 248 | SH4 | SUPPLY AND FIXING STAINLESS STEEL HANDRAIL FOR STAIRS/RAMPS/ACCESSIBILITY, USING 3/4 INCH TO 2 INCH DIA 16-18 GAUGE PIPE INCLUDING BALUSTERS AND ALL FITTINGS, HEIGHT UP TO 900 MM, COMPLETE AS SPECIFIED. | MTR | 25 | ||
| 249 | SH4 | PROVIDING AND LAYING 75 MM THICK PCC 1:2:4 PLINTH PROTECTION/USE FOR WHEELCHAIR RAMP BASE, USING CRUSHED STONES, SURFACE FINISHED AND SMOOTHED WITH CEMENT AND STEEL TROWEL, INCLUDING FORMWORK, COMPLETE AS SPECIFIED. | SQM | 18 | ||
| 250 | SH4 | PROVIDING AND LAYING STANDARD QUALITY NON-SLIP FLOOR TILES FOR WHEELCHAIR RAMPS/ACCESSIBLE AREAS, INCLUDING SETTING, JOINTING AND BONDING, COMPLETE AS SPECIFIED. | SQM | 18 | ||
| 251 | SH4 | SUPPLY AND FIXING STEEL BUTT HINGES, 50 MM LONG, COMPLETE WITH SCREWS AND FIXING, FOR DOORS AND WINDOWS, COMPLETE AS SPECIFIED. | EACH | 150 | ||
| 252 | SH4 | SUPPLY AND FIXING CP TOWER BOLTS, 100 MM LONG, WITH BRIGHT SHOOTS, FIXED WITH SOCKETS OR LET INTO ANY MATERIAL, COMPLETE AS SPECIFIED. | EACH | 50 | ||
| 253 | SH4 | SUPPLY AND FIXING STEEL HANDLE BOW, 150 MM OVERALL, COMPLETE WITH SCREWS, COMPLETE AS SPECIFIED. | EACH | 60 | ||
| 254 | SH4 | SUPPLY AND FIXING STEEL KNOB 30 MM FOR CUPBOARD, HAVING SCREWED END, COMPLETE AS SPECIFIED. | EACH | 40 | ||
| 255 | SH4 | SUPPLY AND FIXING BRASS OR COPPER KICK PLATE (16-18 GAUGE), COMPLETE AS SPECIFIED. | SQM | 8 | ||
| 256 | SH4 | SUPPLY AND FIXING 13 MM THICK SOFT BOARD SHEET, FIXED IN CEILING AND PARTITIONS WITH 1ST CLASS SOFT WOOD (DEODAR) BEVELED EDGE COVER FILLETS 50 MM X 13 MM SCREWED ON, COMPLETE AS SPECIFIED. | SQM | 45 | ||
| 257 | SH4 | SUPPLY AND FIXING FIBRE GLASS CEILING PANELS (1200 MM X 600 MM), SINGLE PLY (NOT LESS THAN 1 MM THICK), IN ANY COLOUR/TEXTURE, INCLUDING ALUMINIUM TEE AND ANGLE 25X25X1 MM, HANGER CLIPS, JOINTING CLIPS AND GI 14 SWG WIRE, INCLUDING OPENINGS FOR LIGHTS, COMPLETE AS SPECIFIED. | SQM | 65 | ||
| 258 | SH4 | SUPPLY AND FIXING PLASTER OF PARIS (POP) CEILING TILES (600 MM X 600 MM X 20 MM), FIXED IN CEILING IN ANY DESIGN, PARTITIONS AND DADOS, COMPLETE AS SPECIFIED. | SQM | 35 | ||
| 259 | SH4 | SUPPLY AND FIXING 10 MM THICK MDF SHEETS CEILING, ALONG WITH HANGING ARRANGEMENTS, ALUMINIUM TEE AND ANGLE 25X25X1 MM, INCLUDING HANGER CLIPS, JOINTING CLIPS, COMPLETE AS SPECIFIED. | SQM | 30 | ||
| 260 | SH5 | IN ANY SOIL DRILLING BORE HOLE 450 MM DIA EMPLOYING REVERSE ROTARY HYDRAULIC PERCUSSION METHOD BORE UPTO 50 M DEPTH COMPLETE. | METRE | 260 | ||
| 261 | SH5 | IN ANY SOIL DRILLING BORE HOLE 450 MM DIA EMPLOYING REVERSE ROTARY HYDRAULIC / PERCUSSION METHOD BORE MORE THAN 50M BUT UPTO 100 M DEPTH COMPLETE. | METRE | 230 | ||
| 262 | SH5 | SUPPLY AND INSTALLATION MS BLIND PIPE 5 MM THICK 250MM DIA WITH WELDING JOINTS COMPLETE. | METRE | 280 | ||
| 263 | SH5 | SUPPLY AND LOWERING IN PREDRILLED BORE HOLE 250 MM DIA V-WIRE V-WEDGE CONTINUOUS SLOT STAINLESS STEEL WATER WELL SCREEN PROPER WELDED WITH MS PIPE COMPLETE. | METRE | 140 | ||
| 264 | SH5 | SUPPLY AND INSTALLATION OF BAIL PLUG 250 MM DIA OF APPROVED SPECIFICATIONS. | EACH | 1 | ||
| 265 | SH5 | SUPPLY AND POURING OF SHROUDING GRAVEL OF REQUISITE GRADE IN ANNULAR SPACE BETWEEN BLIND PIPE/STRAINER AND BORE HOLE ACCORDING TO SPECIFICATIONS FOR 250 MM DIA BLIND PIPE/STRAINER. | METRE | 360 | ||
| 266 | SH5 | PROVISION OF SANITARY SEAL OF APPROVED DESIGN AND SPECIFICATION FOR 250 MM DIA BLIND PIPE. | METRE | 14 | ||
| 267 | SH5 | DEVELOP TEST AND STERILIZE TUBE WELL IN ACCORDANCE WITH APPROVED PROCEDURE 250 MM DIA. | EACH | 1 | ||
| 268 | SH5 | EXCAVATE AS IN ORDINARY SOIL UPTO 1.5 M DEPTH IN FOUNDATION AND PIPE TRENCHES UPTO 1.5M WIDE IN SHAFTS WELLS AND INDEPENDENT HOLES UPTO 30 SQM EACH AND THROW EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10M. TIMBERING TO BE PAID EXTRA. | CUM | 2083 | ||
| 269 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 1.5 MTR BUT NOT EXCEEDING 3 MTR DEPTH. | CUM | 340 | ||
| 270 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 3 MTR BUT NOT EXCEEDING 4.50 MTR DEPTH. | CUM | 42 | ||
| 271 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 4.5 MTR BUT NOT EXCEEDING 6.00 MTR DEPTH. | CUM | 42 | ||
| 272 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 6 MTR BUT NOT EXCEEDING 7.50 MTR DEPTH. | CUM | 42 | ||
| 273 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 7.50 MTR BUT NOT EXCEEDING 9.0 MTR DEPTH. | CUM | 42 | ||
| 274 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 9 MTR BUT NOT EXCEEDING 10.50 MTR DEPTH. | CUM | 42 | ||
| 275 | SH5 | EXCAVATE AS IN ORDINARY SOIL EXCEEDING 10.5 MTR BUT NOT EXCEEDING 12.0 MTR DEPTH. | CUM | 42 | ||
| 276 | SH5 | EXCAVATION AS IN HARD SOIL UPTO 1.5 M DEPTH IN FOUNDATION AND PIPE TRENCHES UPTO 1.5 M WIDE IN SHAFTS WELLS AND INDEPENDENT HOLES UPTO 30 SQM EACH AND THROW EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10M. | CUM | 357 | ||
| 277 | SH5 | EARTH FILLING AS IN ORDINARY OR HARD SOIL FILLING IN FOUNDATION PIPE TRENCHES SHAFTS WELLS INDEPENDENT HOLES UNDER FLOORS OR AROUND PLINTH ETC 1.5 M BELOW OR ABOVE GROUND LEVEL (GL) WITH SPOIL OBTAINED FROM EXCAVATION IN TRENCHES/OVER AREAS WITHIN 10M INCLUDING WATERING AND COMPACTION IN 150MM LAYER AND DRESSING TO REQUIRED PROFILE AND SHAPE. | CUM | 802 | ||
| 278 | SH5 | PROVIDING AND LAYING OF LEAN CONCRETE USING CRUSHED OR BROKEN STONE GRADED 1:4:8 ALL AS SPECIFIED. | CUM | 21 | ||
| 279 | SH5 | PROVIDING AND LAYING OF CC TYPE C USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED. | CUM | 58 | ||
| 280 | SH5 | PROVIDING AND LAYING OF RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH USING WEIGH BATCH CONCRETE INCLUDING PUMP ETC AND TRANSPORTATION UPTO 5 KM BY TRANSIT MIXER AS SPECIFIED IN ROOF SLABS LANDINGS WALLS PLINTH BEAMS AND BANDS ETC INCLUDING FORM WORK (REINFORCEMENT MEASURED AND PAID SEPARATELY). | CUM | 11 | ||
| 281 | SH5 | SUPPLY AND FIX BARS ROUND USING DEFORMED BARS GRADE - 40 INCLUDING CUTTING BENDING BINDING AND PLACING REINFORCEMENT IN POSITION. | KG | 921 | ||
| 282 | SH5 | BURNT BRICK WORK IN WALL OVER 115 MM THICK LAID AND JOINTED IN CEMENT MORTAR 1:4 STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER UPTO 4.25 M DEPTH. | CUM | 65 | ||
| 283 | SH5 | BRICK BATS OR OTHER APPROVED FILLING IN SOKAGE PITS ETC. | CUM | 291 | ||
| 284 | SH5 | PROVIDING AND LAYING 13MM TH CEMENT PLASTER AS IN CM 1:4 WITH PUDLO OR OTHER SIMILAR APPROVED MATERIAL MIXED WITH CEMENT AT THE RATE OF 3% BY WEIGHT COMPLETE ALL AS SPD. | SQM | 1367 | ||
| 285 | SH5 | TUBE WATER QUALITY (GI) WITH ALL FITTINGS (I.E. SOCKETS BENDS TEES ELBOWS WHERE REQUIRED) AND LAID COMPLETE IN TRENCHES (EXCLUDING EXCAVATION) OR FIXED TO WALL FLOOR (SURFACE OR CONCEALED) AND CEILING ETC. INCLUDING CAPS AND PLUGS AS REQUIRED 100 MM DIA (MEDIUM) SUPPLY AND FIXING. | METRE | 1293 | ||
| 286 | SH5 | POLYETHYLENE PIPE (PE-100) 63 MM DIA CLASS PN-10/SDR-17 LAID IN TRENCHES (EXCLUDING EXCAVATION) SUPPLY AND FIXING. | MTR | 92 | ||
| 287 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 20 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 192 | ||
| 288 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 25 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 1299 | ||
| 289 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 32 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 697 | ||
| 290 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 40 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 350 | ||
| 291 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 50 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 207 | ||
| 292 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 63 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 23 | ||
| 293 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 75 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 705 | ||
| 294 | SH5 | PPR PIPE WITH ALL FITTINGS I.E. SOCKET BEND TEE ELBOW WHERE REQUIRED 110 MM DIA CLASS PN-20 (EXCL EXCAVATION) SUPPLY AND FIXING. | MTR | 5 | ||
| 295 | SH5 | POLYETHYLENE PIPE (PE-100) 160 MM DIA CLASS PN-16 / SDR-11 (EXCLUDING COST OF EXCAVATION) SUPPLY AND FIXING. | METRE | 1900 | ||
| 296 | SH5 | SUPPLY AND FIX RCC PIPES 300 MM BORE LAID AND JOINTED WITH SPIGOT SOCKET OR TONGUE AND GROOVE JOINT INCLUDE RUBBER RING AS SPECIFIED. | MTR | 1866 | ||
| 297 | SH5 | SUPPLY AND FIX UPVC SOIL AND WASTE PIPE 160MM BORE (OUTSIDE DIA) COMPLETE WITH PLAIN END AND SOLVENT CEMENT JOINT AS SPECIFIED. | MTR | 58 | ||
| 298 | SH5 | PPR COUPLER / SOCKET 40 MM DIA SUPPLY AND FIXING. | EACH | 5 | ||
| 299 | SH5 | SUPPLY AND FIX UPVC EQUAL TEE 160MM DIA COMPLETE WITH SOLVENT CEMENT JOINT ALL AS SPECIFIED. | NO | 6 | ||
| 300 | SH5 | BALL TAP WITH HANDLE 20 MM DIA FOR PPR PIPE. | EACH | 16 | ||
| 301 | SH5 | BALL TAP WITH HANDLE 25 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 108 | ||
| 302 | SH5 | BALL TAP WITH HANDLE 32 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 16 | ||
| 303 | SH5 | BALL TAP WITH HANDLE 40 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 20 | ||
| 304 | SH5 | BALL TAP WITH HANDLE 50 OR 60 MM DIA FOR PPR PIPE. | EACH | 2 | ||
| 305 | SH5 | BALL TAP WITH HANDLE 63 MM DIA FOR PPR PIPE. | EACH | 9 | ||
| 306 | SH5 | SCREW TAP WITH HANDLE 32 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 4 | ||
| 307 | SH5 | SCREW TAP WITH HANDLE 40 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 6 | ||
| 308 | SH5 | SCREW TAP WITH HANDLE 50 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 3 | ||
| 309 | SH5 | SCREW TAP WITH HANDLE 63 MM DIA FOR PPR PIPE SUPPLY AND FIXING. | EACH | 1 | ||
| 310 | SH5 | BIB COCK BRASS CP FANCY TYPE SCREWED DOWN BSP 15 MM DIA. | EACH | 27 | ||
| 311 | SH5 | STOP COCK BRASS CP SCREW DOWN HIGH PRESSURE FANCY TYPE 15MM DIA. BUT CONCEALED TYPE. | EACH | 54 | ||
| 312 | SH5 | STOP COCK BRASS CP SCREW DOWN HIGH PRESSURE FANCY TYPE 15MM DIA. BUT TEE STOP COCK. | EACH | 114 | ||
| 313 | SH5 | FLOAT VALVES BRASS (CORYDON) OR OTHER APPROVED PATTERN WITH PLASTIC BALL SCREWED FOR IRON (BRASS FERRULE) WITH COPPER BALL 40MM DIA. | EACH | 4 | ||
| 314 | SH5 | FLOAT VALVES BRASS (CORYDON) OR OTHER APPROVED PATTERN WITH PLASTIC BALL SCREWED FOR IRON (BRASS FERRULE) WITH COPPER BALL 50MM DIA. | EACH | 1 | ||
| 315 | SH5 | GLOBE VALVES GUNMETAL SCREWED BOTH ENDS COMPLETE WITH STEEL HANDLE CLASS-150 40 MM DIA SUPPLY AND FIXING. | EACH | 10 | ||
| 316 | SH5 | GLOBE VALVES GUNMETAL SCREWED BOTH ENDS COMPLETE WITH STEEL HANDLE CLASS-150 50 MM DIA SUPPLY AND FIXING. | EACH | 10 | ||
| 317 | SH5 | GLOBE VALVES GUNMETAL FLANGED AND DRILLED TO BS TABLE 18-1-10 COMPLETE WITH STEEL HANDLE CLASS-150 80MM DIA SUPPLY AND FIXING. | EACH | 12 | ||
| 318 | SH5 | SLUICE VALVE ACCORDING TO BSS-3464 CLASS 150 (TABLE 18-1-6) FLANGED AND DRILLED TO BS TABLE 18-1-10 COMPLETE WITH RUBBER PACKING 100 MM DIA SUPPLY AND FIXING. | EACH | 1 | ||
| 319 | SH5 | SLUICE VALVE ACCORDING TO BSS-5150/5163 PN-16 (TABLE 18-1-8) FLANGED AND DRILLED TO BS TABLE 18-1-10 COMPLETE WITH RUBBER PACKING 150 MM DIA SUPPLY AND FIXING. | EACH | 18 | ||
| 320 | SH5 | SUPPLY AND FIXING OF NON RETURN VALVE OR REFLUX VALVE SCREWED 15 MM DIA. | EACH | 2 | ||
| 321 | SH5 | SUPPLY AND FIXING OF NON RETURN VALVE OR REFLUX VALVE SCREWED 20 MM DIA. | EACH | 4 | ||
| 322 | SH5 | SUPPLY AND FIXING OF NON RETURN VALVE OR REFLUX VALVE SCREWED 150 MM DIA | EACH | 2 | ||
| 323 | SH5 | SOCKET GI 150 MM DIA SUPPLY AND FIXING. | EACH | 12 | ||
| 324 | SH5 | BEND GI 45 DEG / 90 DEG 150 MM DIA SUPPLY AND FIXING. | EACH | 8 | ||
| 325 | SH5 | SUPPLY AND FIX GUARD BARS GRILLS RAILING LADDERS BRACKETS HOOKS HOLD FASTS AND FRAMES ETC CUT TO DEAD LENGTH REDUCED TO SIZE SHAPE FIGURE ETC INCLUDING PUNCHING / DRILLING HOLES IF NECESSARY AND FIXING ASSEMBLING BY WELDING OR WITH THE USE OF BOLTS NUTS RIVETS WASHERS ETC AND ERECTION/FIXING IN POSITION INCLUDING MAKING GOOD THE DISTURBED SURFACES. | KG | 41 | ||
| 326 | SH5 | SUPPLY AND FIX XPM EXPENDED METAL 25MM X 25MM MASH 18 GAGUE BRC FABRIC WELD MESH MAXWELD ETC IN REINFORCEMENT OR IN OTHER POSITIONS LIKE DOORS PARTITION AND LATHING FOR PLASTER TO SHAPE SIZE AS REQUIRED INCLUDING BINDING WITH 14 SWG WIRE NAILS STAPLES ETC AND PLACING IN POSITION MEASURED NET. | SQM | 3 | ||
| 327 | SH5 | MANHOLES COMPLETE RECTANGULAR OR CIRCULAR AS DESCRIBED EXCEEDING 600 MM DEEP BUT NOT EXCEEDING 1800 MM DEEP WITH IRON STEPS (IN ANGLES 380 MM CENTRES) 230MM THICK BRICK WALLS (EXCEPT MANHOLE COVER). | CUM | 269 | ||
| 328 | SH5 | PROVIDING AND LAYING RCC TYPE B MANHOLE COVER (PRECAST COMPLETE WITH ANGLE IRON FRAME EMBEDDED IN CONCRETE ALL AS PER INFORMATION SHEET NO. SVCS-341 DATED 10-11-99. | NO | 141 | ||
| 329 | SH5 | EXCAVATE DISPOSE SPOIL SUPPLY SURFACE GULLIES (230X230X100 MM) WITH 100 MM PCC SURROUND AND CI GRATING COMPLETE. | EACH | 6 | ||
| 330 | SH5 | DEMOLITION OF PLAIN CEMENT CONCRETE. | CUM | 23.986318315808 | ||
| 331 | SH5 | SUPPLY AND FIX WALL SHOWER SET SINGLE LEVER CP (PREMIUM) CONSISTING OF A WALL SHOWER, DOUBLE BIB COCK, TEE STOP COCK, BASIN MIXER AND TOILET SHOWER COMPLETE ALL AS SPECIFIED | EACH | 8 | ||
| 332 | SH5 | SUPPLY AND FIXING BASIN MIXER SINGLE LEVER CP, 15MM DIA INCLUDING PIPE CONNECTION COMPLETE AS SPECIFIED. | EACH | 8 | ||
| 333 | SH5 | SUPPLY AND FIXING SINK MIXER CP SINGLE LEVER HIGH NECK FANCY, 15 MM DIA, INCLUDING PIPE CONNECTION COMPLETE ALL AS SPECIFIED | EACH | 8 | ||
| 334 | SH5 | SUPPLY AND FIXING OF WHITE GLAZED EARTHENWARE ASIATIC-PATTERN WATER CLOSET (WC) NOT LESS THAN 550 MM LONG COMPLETE WITH FLUSHING CISTERN FLUSH PIPE AND CONNECTIONS COMPLETE AS SPECIFIED. | NO | 6 | ||
| 335 | SH5 | SUPPLY AND FIXING OF GLAZED-WARE WASH BASIN/VANITY BOWL WITH SINGLE FAUCET HOLE INCLUDING BOTTLE TRAP WASTE COUPLING CP BASIN MIXER AND ALL CONNECTIONS COMPLETE AS SPECIFIED. | NO | 6 | ||
| 336 | SH5 | SUPPLY AND FIXING OF 5 MM THICK SILVERED GLASS MIRROR (ANY SHAPE: RECTANGULAR CIRCULAR OR OVAL) WITH GROUND AND POLISHED EDGES FIXED TO WALL WITH SCREWS AND PLUGS COMPLETE AS SPECIFIED. | SQM | 6 | ||
| 337 | SH5 | SUPPLY AND FIXING OF PLASTIC SHELF (ANY SIZE AND SHAPE) WITH SCREWS AND WALL PLUGS COMPLETE AS SPECIFIED. | EACH | 6 | ||
| 338 | SH5 | SUPPLY AND FIXING OF CHROME-PLATED (CP) SINGLE-ROD TOWEL RAIL ANY PATTERN AND SIZE WITH SCREWS AND WALL PLUGS COMPLETE AS SPECIFIED. | EACH | 6 | ||
| 339 | SH5 | ELECTRIC GEYSER 45 LIT CAPACITY COMPLETE WITH THERMOSTAT SAFETY VALVE SUPPLY AND FIXING. | EACH | 2 | ||
| 340 | SH5 | ELECTRIC WATER COOLER SP 220/240V COOLING CAPACITY 60 LIT/HR COMPLETE SUPPLY AND FIXING. | EACH | 6 | ||
| 341 | SH5 | HYPO-CHLORINATOR SOLENOID TYPE HAVING LIQUID CHLORINE FEEDING CAPACITY 20 GPD AT 150 PSI FITTED WITH FLOW RATE CONTROL KNOB MANUALLY ADJUSTABLE 0-100% OPERATED AT 220/240V 50 HZ DIAPHRAGM TYPE OF NON-CORROSIVE MATERIAL WITH STANDARD SUCTION/DISCHARGE TUBING INJECTOR PRESSURE AUTO RELIEF VALVE ANTI-SIPHON VALVE SOLUTION STORAGE TANK OF 50 GAL CAPACITY PE/PVC WITH STAND DULY PAINTED AS SPECIFIED SUPPLY AND FIXING. | EACH | 2 | ||
| 342 | SH5 | PUMPING SET SUBMERSIBLE WITH AC ELECTRIC MOTOR DRIVEN 400 V 3 PHASE 50 CYCLES COMPLETE WITH PUMP MOTOR CABLE COLUMN PIPES MOTOR CONTROL UNIT PUMP CAPACITY 0.5 CUSEC UPTO 97 M HEAD PUMP SETTING 60 M WITH 82-91 HP MOTOR 2900 RPM MOTOR EFFICIENCY IE2 INSULATION CLASS F ENCLOSURE CHARACTERISTICS IP-68 SUPPLY AND FIXING. | EACH | 2 | ||
| 343 | SH6 | CLEARING AND GRUBBING THE SITE INCLUDING REMOVAL OF GRASS, SHRUBS, BRUSHWOOD, UNDERGROWTH, ROOTS, AND SMALL TREES NOT EXCEEDING 225 MM GIRTH, DISPOSING OF CLEARED MATERIAL OFF-SITE, COMPLETE AS SPECIFIED. | SQM | 92 | ||
| 344 | SH6 | EXCAVATION IN ORDINARY SOIL UP TO 1.5 M DEPTH, IN FOUNDATION AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M; TIMBERING TO BE PAID EXTRA, COMPLETE AS SPECIFIED. | CUM | 11324 | ||
| 345 | SH6 | EXCAVATION IN HARD SOIL UP TO 1.5 M DEPTH, IN FOUNDATION AND PIPE TRENCHES UP TO 1.5 M WIDE, IN SHAFTS, WELLS AND INDEPENDENT HOLES UP TO 30 SQM EACH, THROWING EARTH CLEAR OF EDGES OF EXCAVATION WITHIN 10 M; TIMBERING TO BE PAID EXTRA, COMPLETE AS SPECIFIED. | CUM | 903 | ||
| 346 | SH6 | EXCAVATION OVER AREAS IN ORDINARY/HARD SOIL FROM 1.5 M TO 3 M DEPTH, IN FOUNDATION/EXCAVATIONS, THROWING EARTH CLEAR WITHIN 50 M; FOR DEEP EXCAVATION OF SEMI-UNDERGROUND UAV BUNKER STRUCTURES. | CUM | 400 | ||
| 347 | SH6 | EARTH FILLING IN ORDINARY OR HARD SOIL, IN FOUNDATION, PIPE TRENCHES, SHAFTS, WELLS, INDEPENDENT HOLES, UNDER FLOORS OR AROUND PLINTH ETC., 1.5 M BELOW OR ABOVE GROUND LEVEL, WITH SPOIL OBTAINED FROM EXCAVATION IN TRENCHES/OVER AREAS WITHIN 50 M, INCLUDING WATERING AND COMPACTION IN 150 MM LAYERS AND DRESSING TO REQUIRED PROFILE AND SHAPE. | CUM | 468 | ||
| 348 | SH6 | MAKING EMBANKMENT WITH SPECIFIED/APPROVED SOIL OBTAINED FROM BORROW EXCAVATION, INCLUDING LOADING WITHIN 5 KM, COMPACTION IN 150 MM LAYERS UP TO 95% MODIFIED AASHTO DENSITY, AND DRESSING TO REQUIRED PROFILE AND SHAPE. | CUM | 200 | ||
| 349 | SH6 | CUT OR FILL IN GRANULAR SOIL NOT EXCEEDING 150 MM, COMPACTING THE FORMATION SURFACE BY COMPACTION EQUIPMENT AND ROLLER UP TO 100% MODIFIED AASHTO DENSITY, INCLUDING FILLING DEPRESSIONS WITH HARD SOIL. | SQM | 92 | ||
| 350 | SH6 | LOADING OF EXCAVATED SOIL, ROCK, DEMOLISHED BRICK BATS, BRICKS, SAND AND BITUMEN ETC. BY ANY MEANS UP TO 1000 M, UNLOADING AND STACKING OR SPREADING, PLUS CARRIAGE FOR EACH SUBSEQUENT 5 KM OR PART THEREOF. | CUM | 130 | ||
| 351 | SH6 | MAKING EMBANKMENT WITH SPECIFIED/APPROVED SOIL OBTAINED FROM BORROW EXCAVATION FOR EARTH COVERING OVER UAV BUNKER ROOFS FOR CAMOUFLAGE AND THERMAL INSULATION, INCLUDING LOADING, PLACING IN LAYERS, AND COMPACTION, COMPLETE AS SPECIFIED. | CUM | 250 | ||
| 352 | SH6 | GRANULAR BACKFILLING USING APPROVED GRANULAR SUB-BASE MATERIAL, LAID AND COMPACTED IN LAYERS TO 100% MODIFIED AASHTO DENSITY, COMPLETE AS SPECIFIED. | CUM | 534 | ||
| 353 | SH6 | PROVIDING SAND CUSHION IN LAYERS AS SPECIFIED, UNDER CONCRETE SLABS, HARD STANDINGS AND RUNWAYS ETC., COMPLETE. | CUM | 250 | ||
| 354 | SH6 | PROVIDING AND LAYING LEAN CONCRETE (PCC 1:4:8) USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED, COMPLETE. | CUM | 721 | ||
| 355 | SH6 | PROVIDING AND LAYING LEAN CONCRETE (PCC 1:3:6) USING CRUSHED OR BROKEN STONE GRADED AS SPECIFIED, COMPLETE. | CUM | 104 | ||
| 356 | SH6 | PROVIDING AND LAYING PCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ALL STRUCTURAL/NON-STRUCTURAL ELEMENTS (E.G., STEPS), INCLUDING FORMWORK AND FAIR FACES TO EXPOSED SURFACES. | CUM | 125 | ||
| 357 | SH6 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN DIFFERENT STRUCTURAL ELEMENTS (FOUNDATION ETC.) INCLUDING FORMWORK, COMPLETE; REINFORCEMENT MEASURED AND PAID SEPARATELY. | CUM | 2382 | ||
| 358 | SH6 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ROOF SLABS, LANDINGS, WALLS, PLINTH BEAMS AND BANDS ETC., INCLUDING FORMWORK; REINFORCEMENT MEASURED AND PAID SEPARATELY. | CUM | 337 | ||
| 359 | SH6 | PROVIDING AND LAYING RCC WITH 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN COLUMNS, BEAMS, STAIRS, POSTS, STRUTS, PIERS, LINTELS AND THE LIKE, INCLUDING FORMWORK; REINFORCEMENT MEASURED AND PAID SEPARATELY. | CUM | 1751 | ||
| 360 | SH6 | PROVIDING AND LAYING RCC WITH 4000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ROOF SLABS, LANDINGS, WALLS, PLINTH BEAMS AND BANDS, INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY; FOR UAV BUNKER ROOF SLAB WITH WATERPROOFING MEMBRANE. | CUM | 90 | ||
| 361 | SH6 | PROVIDING AND LAYING RCC WITH 4000 PSI COMPRESSIVE CYLINDRICAL STRENGTH IN ROOF SLABS, LANDINGS, WALLS, PLINTH BEAMS AND BANDS, INCLUDING FORMWORK; REINFORCEMENT PAID SEPARATELY; FOR UAV BUNKER ROOF SLAB WITH WATERPROOFING MEMBRANE. | CUM | 55 | ||
| 362 | SH6 | SUPPLY AND FIXING DEFORMED STEEL BARS GRADE-60 REINFORCEMENT, INCLUDING CUTTING, BENDING, BINDING WITH 16 SWG WIRE, AND PLACING IN POSITION AT ANY HEIGHT/LEVEL, COMPLETE AS SPECIFIED. | KG | 3212598.9501584 | ||
| 363 | SH6 | BURNT BRICK WORK IN WALLS OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:4, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO GROUND FLOOR ROOF LEVEL, COMPLETE. | CUM | 211 | ||
| 364 | SH6 | BURNT BRICK WORK IN WALLS OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:6, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO GROUND FLOOR ROOF LEVEL, COMPLETE. | CUM | 128 | ||
| 365 | SH6 | BURNT BRICK WORK IN WALLS OVER 115 MM THICK, LAID AND JOINTED IN CEMENT MORTAR 1:6, STRAIGHT OR TO CURVE WITH INNER RADIUS OF 6 M AND OVER, UP TO FIRST FLOOR ROOF LEVEL, COMPLETE. | CUM | 141 | ||
| 366 | SH6 | PROVIDING AND LAYING PCC SOLID BLOCKS FOR NON-LOAD-BEARING WALLS, INCLUDING SETTING AND JOINTING IN CEMENT MORTAR 1:6, UP TO GROUND FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 5215 | ||
| 367 | SH6 | PROVIDING AND LAYING PCC HOLLOW BLOCKS FOR NON-LOAD-BEARING WALLS, INCLUDING SETTING AND JOINTING IN CEMENT MORTAR 1:6, UP TO BASEMENT/GROUND FLOOR ROOF LEVEL, COMPLETE AS SPECIFIED. | CUM | 6 | ||
| 368 | SH6 | PROVIDING AND LAYING 50 MM THICK PCC 1:2:4 USING 3 MM AGGREGATE, FINISHED SMOOTH WITH STEEL FLOAT, COVERED WITH TWO COATS OF HOT BITUMEN AT 0.75 KG PER SQM EACH, AND BLINDED WITH 0.012 CUM OF SAND PER SQM. | SQM | 1398 | ||
| 369 | SH6 | PROVIDING AND LAYING A BOND-BREAKING SLIP MEMBRANE BENEATH FLOOR SLABS, CONSISTING OF 0.102 MM THICK POLYETHYLENE FILM LAID OVER THE PREPARED SUB-BASE, COMPLETE AS SPECIFIED. | SQM | 29 | ||
| 370 | SH6 | PROVIDING AND APPLYING TWO COATS OF HOT-APPLIED BITUMEN (10/20 GRADE) ON ROOF SURFACE AT 0.75 KG PER SQM PER COAT, EACH COAT BLINDED WITH SAND AT 0.012 CUM PER SQM, INCLUDING CLEANING AND PREPARATION OF THE SURFACE, COMPLETE. | SQM | 269 | ||
| 371 | SH6 | TERMITE PROOFING OF NEW BUILDINGS/FOUNDATIONS WITH APPROVED CHEMICALS (EXCEPT JOINERY), APPLIED TO BEDS AND SIDES OF EXCAVATED TRENCHES, BACKFILLS, FILLED-UP EARTH, AND SURROUNDING AREAS WITHIN 5 M OF THE BUILDING, COMPLETE WITH 5-YEAR WARRANTY. | SQM | 51 | ||
| 372 | SH6 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:4 MIX) ON INTERNAL WALL SURFACES (BASEMENT, GROUND, FIRST AND SECOND FLOORS), FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 1061 | ||
| 373 | SH6 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:6 MIX) ON WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 110 | ||
| 374 | SH6 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:3 MIX) ON WALL SURFACES (BASEMENT, GROUND, FIRST AND SECOND FLOORS), FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 3854 | ||
| 375 | SH6 | PROVIDING AND LAYING 13 MM THICK TERRAZZO DADO/SKIRTING (MARBLE CHIPS MIXED WITH ORDINARY CEMENT IN 1:2 RATIO) ON A 1:3 CEMENT PLASTER BASE, INCLUDING CUTTING AND RUBBING, COMPLETE. | SQM | 16 | ||
| 376 | SH6 | PROVIDING AND LAYING 80 MM THICK HYDRAULICALLY-COMPRESSED PCC PAVING STONES IN NATURAL COLOUR, IN ANY PATTERN OR SHAPE, LAID AND JOINTED IN SAND ON A 50 MM THICK SAND BEDDING COURSE, FOR FLOORS, LOADING DECKS AND HEAVY-DUTY AREAS, COMPLETE AS SPECIFIED. | SQM | 75139 | ||
| 377 | SH6 | PROVIDING AND LAYING 80 MM THICK HYDRAULICALLY-COMPRESSED PCC PAVING STONES IN ANY COLOUR OTHER THAN NATURAL, IN ANY PATTERN OR SHAPE, LAID AND JOINTED IN SAND ON A 50 MM THICK SAND BEDDING COURSE, COMPLETE AS SPECIFIED. | SQM | 322 | ||
| 378 | SH6 | PROVIDING AND LAYING 20 MM THICK TERRAZZO FLOOR USING MARBLE CHIPS (1:2) WITH ORDINARY CEMENT, INCLUDING CUTTING, RUBBING, CLEANING AND CHEMICAL POLISHING, COMPLETE AS SPECIFIED. | SQM | 11 | ||
| 379 | SH6 | SUPPLY AND FIXING 8-10 MM THICK AND 40 MM WIDE MARBLE PATTY AS DIVIDING STRIPS IN FLOORS, COMPLETE AS SPECIFIED. | MTR | 12 | ||
| 380 | SH6 | PROVIDING AND LAYING PCC 1:4:8 UNDER FLOOR USING CRUSHED OR BROKEN STONES, COMPLETE AS SPECIFIED. | CUM | 64 | ||
| 381 | SH6 | PROVIDING AND LAYING PCC 1:2:4 IN FLOOR SLABS, SURFACE FINISHED SMOOTH WITH NEAT CEMENT AND STEEL TROWEL, USING CRUSHED OR BROKEN STONE, FOR BASEMENT/GROUND FLOOR, COMPLETE AS SPECIFIED. | CUM | 2 | ||
| 382 | SH6 | PROVIDING AND LAYING 50 MM THICK FLOOR TOPPING WITH PCC OF 3000 PSI COMPRESSIVE CYLINDRICAL STRENGTH, COMPLETE AS SPECIFIED. | SQM | 389 | ||
| 383 | SH6 | PROVIDING AND LAYING PAVEMENT QUALITY CONCRETE (PQC) OF 600 PSI FLEXURAL STRENGTH FOR RUNWAY, TAXIWAY LINKS, LEAD-INS AND TARMAC, OF ANY THICKNESS, USING AN APPROVED CONCRETE MIX DESIGN, LAID MANUALLY, COMPLETE AS SPECIFIED. | CUM | 73 | ||
| 384 | SH6 | PROVIDING AND LAYING 75 MM THICK PCC 1:2:4 PLINTH PROTECTION USING CRUSHED STONES, SURFACE FINISHED AND SMOOTHED WITH CEMENT AND STEEL TROWEL, INCLUDING FORMWORK, COMPLETE AS SPECIFIED. | SQM | 79 | ||
| 385 | SH6 | PROVIDING AND LAYING PCC 1:3:6 IN FLOOR SLABS, SURFACE FINISHED SMOOTH WITH CEMENT AND STEEL TROWEL USING CRUSHED OR BROKEN STONES, FOR BASEMENT/GROUND FLOOR, COMPLETE AS SPECIFIED. | CUM | 4 | ||
| 386 | SH6 | PROVIDING AND FIXING 22 BG CORRUGATED GALVANIZED IRON (CGI) ROOFING SHEETS ON THE VEHICLE SHED ROOF, FIXED TO TIMBER/STEEL PURLINS WITH ONE-AND-A-HALF CORRUGATION SIDE LAPS AND 150 MM END LAPS, USING GALVANIZED SCREWS, FIBRE WASHERS, AND CURVED/LIMPET WASHERS AT CENTRES NOT EXCEEDING 380 MM, COMPLETE AS SPECIFIED. | SQM | 558 | ||
| 387 | SH6 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF A MOTORIZED SLIDING/OPENING MECHANISM WITH REMOTE CONTROL FOR THE HEAVY-DUTY STEEL GATE, INCLUDING MOTOR, DRIVE, CONTROLS, SAFETY SENSORS, AND ALL ACCESSORIES, COMPLETE AS SPECIFIED. | JOB | 1 | ||
| 388 | SH6 | SUPPLY OF HIGH-STRENGTH WOVEN POLYPROPYLENE HESCO/DEFENCE BARRIER BAGS, 4 FT X 4 FT X 8 FT (L X W X H), WITH UV-STABILIZED COATING AND INTEGRAL FILLING SPOUTS, COMPLETE AS SPECIFIED. | NOS | 15000 | ||
| 389 | SH6 | PROVIDING AND PLACING APPROVED IMPORTED SAND/EARTH FILLING MATERIAL INTO HESCO BARRIER BAGS, INCLUDING LOADING, TRANSPORTATION TO SITE, UNLOADING AND FILLING, COMPLETE AS SPECIFIED. | CUM | 1258.5 | ||
| 390 | SH6 | PROVIDING AND FIXING TWO STRANDS OF GALVANIZED 12 SWG BARBED WIRE (4-POINT BARBS AT 75 MM CENTRES) ON ANGLED STEEL BRACKETS ALONG THE TOP OF THE HESCO WALL, FIXED WITH GI STAPLES AND TENSIONED, COMPLETE AS SPECIFIED. | MTR | 3900 | ||
| 391 | SH6 | SUPPLY AND FIXING OF GUARD BARS, GRILLS, RAILINGS, LADDERS, BRACKETS, HOOKS, HOLDFASTS AND FRAMES ETC., CUT TO DEAD LENGTH, REDUCED TO SIZE AND SHAPE, PUNCHED/DRILLED AS NECESSARY, ASSEMBLED BY WELDING OR WITH BOLTS/NUTS/RIVETS/WASHERS, AND ERECTED/FIXED IN POSITION, INCLUDING MAKING GOOD DISTURBED SURFACES, COMPLETE AS SPECIFIED. | KG | 33828 | ||
| 392 | SH6 | SUPPLY AND FIXING OF ROUND, SQUARE OR FLAT STEEL BARS INCLUDING CUTTING, BENDING, BINDING AND PLACING REINFORCEMENT IN POSITION, COMPLETE AS SPECIFIED. | KG | 714 | ||
| 393 | SH6 | SUPPLY AND FIXING OF BOLTS EXCEEDING 10 MM BUT NOT EXCEEDING 18 MM DIAMETER, LENGTH EXCEEDING 75 MM AND NOT EXCEEDING 150 MM, WITH HEXAGON/SQUARE/CUP/CHEESE HEADS, SCREWED ONE OR BOTH ENDS, EACH WITH ONE WASHER AND ONE HEXAGON OR SQUARE NUT, COMPLETE AS SPECIFIED. | EACH | 2762 | ||
| 394 | SH6 | SUPPLY AND FIXING OF 2 INCH X 2 INCH SQUARE MS HOLLOW PIPE SECTION, 16 GAUGE, INCLUDING CUTTING, WELDING, JOINTING AND ERECTION IN POSITION, COMPLETE AS SPECIFIED. | MTR | 396 | ||
| 395 | SH6 | SUPPLY AND FIXING OF GALVANIZED IRON WIRE NETTING, 50 MM X 50 MM MESH, 10 SWG, FIXED WITH TINNED TACKS AND GI STAPLES, COMPLETE AS SPECIFIED. | SQM | 2928 | ||
| 396 | SH6 | PROVIDING AND FIXING TWO STRANDS OF GALVANIZED 12 SWG BARBED WIRE (4-POINT BARBS AT 75 MM CENTRES) ON POSTS/BRACKETS, FIXED WITH GI STAPLES/NAILS, INCLUDING CONNECTING UP ENDS AND TENSIONING, MEASURED PER LINEAR METRE, COMPLETE AS SPECIFIED. | MTR | 57009 | ||
| 397 | SH6 | SUPPLY AND FIXING OF CONCERTINA/RAZOR WIRE, SINGLE COIL, 10/12 GAUGE GALVANIZED WIRE, LOOP DIAMETER 0.452 TO 0.990 M, COMPLETE WITH ALL ACCESSORIES, ALL AS SPECIFIED. | MTR | 8701 | ||
| 398 | SH6 | SUPPLY AND FIXING OF MS DT-TYPE CLAMP BRACKET, FABRICATED AS PER APPROVED DRAWING, INCLUDING BOLTS, NUTS AND WASHERS, COMPLETE AS SPECIFIED. | EACH | 789.23 | ||
| 399 | SH6 | SUPPLY AND FIXING OF UPVC DOOR, 60 MM THICK SHUTTER WITH 20 MM THICK GROOVE PANEL FILLED INSTEAD OF GLASS, WITH FRAME, EXCEEDING 1.9 SQM EACH, IN WHITE COLOUR, INCLUDING ALL NECESSARY FITTINGS AND MONGERY, COMPLETE AS SPECIFIED. | SQM | 79 | ||
| 400 | SH6 | SUPPLY AND FIXING OF BOX-PIPE TYPE OPENABLE/FIXED SIDE-HUNG STEEL WINDOW (OR CSW), FABRICATED FROM 16 GAUGE MS FRAME SECTION 50 MM X 25 MM AND Z-SHAPED PANEL 38 X 31 X 38 MM WITH 10 X 10 MM SQUARE GOLA, NOT EXCEEDING 1.48 SQM EACH, INCLUDING ALL FITTINGS, MONGERY, HOLDFASTS, TWO COATS OF SYNTHETIC ENAMEL PAINT OVER ONE COAT OF PRIMER, AND 5 MM THICK PLAIN SHEET GLASS, COMPLETE AS SPECIFIED. | SQM | 36 | ||
| 401 | SH6 | SUPPLY AND FIXING OF HEAVY-DUTY REINFORCED STEEL GATE FOR UAV TAXIWAY ACCESS (30 FT WIDE &12 FT HIGH), APPROX. 20 KG/SQM, INCLUDING CUTTING, WELDING, ERECTION, HINGES, GUIDES, LOCKING MECHANISM, AND TWO COATS OF ENAMEL PAINT OVER PRIMER, COMPLETE AS SPECIFIED. | NOS | 1 | ||
| 402 | SH6 | SUPPLY AND FIXING OF STEEL DOOR AS PER APPROVED DRAWING, FABRICATED FROM MS SHEET/SECTIONS WITH NECESSARY STIFFENERS, HINGES, LOCKS, HANDLES, AND TWO COATS OF ENAMEL PAINT OVER PRIMER, APPROX. 25 KG/SQM, COMPLETE AS SPECIFIED. | SQM | 3 | ||
| 403 | SH6 | SUPPLY AND INSTALLATION OF BLAST-RESISTANT STEEL DOOR FOR UAV BUNKER, HEAVY-DUTY CONSTRUCTION WITH AIRTIGHT NEOPRENE GASKET SEALING, MULTI-POINT LOCKING SYSTEM, AND BLAST-RATED HINGES, COMPLETE WITH ALL HARDWARE AND FACTORY FINISH AS SPECIFIED. | NOS | 2 | ||
| 404 | SH6 | PROVIDING AND APPLYING 13 MM THICK CEMENT-SAND PLASTER (1:4 MIX) ON INTERNAL WALL SURFACES, FINISHED SMOOTH, COMPLETE AS SPECIFIED. | SQM | 131 | ||
| 405 | SH6 | APPLYING ONE COAT OF APPROVED WEATHER-RESISTANT EXTERIOR EMULSION PAINT ON NEW PLASTERED EXTERIOR WALL SURFACES, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 613 | ||
| 406 | SH6 | APPLYING SECOND AND SUBSEQUENT COATS OF APPROVED WEATHER-RESISTANT EXTERIOR EMULSION PAINT ON PREVIOUSLY PRIMED/COATED EXTERIOR WALL SURFACES, COMPLETE AS SPECIFIED. | SQM | 613 | ||
| 407 | SH6 | APPLYING A THREE-COAT SYSTEM OF APPROVED WEATHER-RESISTANT EXTERIOR EMULSION PAINT (ONE PRIMER COAT PLUS TWO FINISH COATS) ON NEW PLASTERED EXTERIOR WALL SURFACES, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 2678 | ||
| 408 | SH6 | APPLYING ONE COAT OF LIME WHITEWASH (FAT LIME SLAKED AND STRAINED) ON NEW OR OLD WALL/CEILING SURFACES, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 66 | ||
| 409 | SH6 | APPLYING SECOND AND SUBSEQUENT COATS OF LIME WHITEWASH ON PREVIOUSLY WHITEWASHED WALL/CEILING SURFACES, COMPLETE AS SPECIFIED. | SQM | 66 | ||
| 410 | SH6 | APPLYING A THREE-COAT LIME WHITEWASH FINISH ON NEW OR OLD WALL/CEILING SURFACES, INCLUDING SURFACE PREPARATION AND CLEANING, COMPLETE AS SPECIFIED. | SQM | 59398 | ||
| 411 | SH6 | APPLYING A THREE-COAT OIL-BOUND DISTEMPER (OR POLYVINYL DISTEMPER) FINISH ON NEW OR OLD PLASTERED WALL SURFACES, INCLUDING SURFACE PREPARATION, COMPLETE AS SPECIFIED. | SQM | 1483 | ||
| 412 | SH6 | APPLYING TWO COATS OF SYNTHETIC ENAMEL PAINT ON NEW OR OLD STEEL DOORS, WINDOWS AND CSWS, INCLUDING SURFACE PREPARATION (CLEANING, SANDING, PRIMING WHERE REQUIRED), COMPLETE AS SPECIFIED. | SQM | 72 | ||
| 413 | SH6 | APPLYING THREE COATS OF SYNTHETIC ENAMEL PAINT ON MS GRILLS/RAILINGS, INCLUDING SURFACE PREPARATION (REMOVAL OF RUST, SCALE AND OLD PAINT), COMPLETE AS SPECIFIED. | SQM | 75 | ||
| 414 | SH7 | EXCAVATION OF CABLE TRENCH UP TO 3 FEET DEEP AND 1.5 FEET WIDE FOR LAYING OF AIRFIELD LIGHTING PRIMARY CABLE OF ANY DESCRIPTION 6MM2 ON DESIRED LOCATION INCLUDING BACKFILLING IN LAYERS WITH COVERING LAYER OF SAND AROUND THE CABLE WARNING TAPE AND TILES/BRICKS COMPACTION AND MAKING GOOD AS PER PAK PWD SPECIFICATIONS. | MTR | 2000 | ||
| 415 | SH7 | EXCAVATION OF CABLE TRENCH UP TO 3 FEET DEEP AND 3 FEET WIDE FOR LAYING OF AIRFIELD LIGHTING PRIMARY CABLE OF ANY DESCRIPTION 6MM2 ON DESIRED LOCATION INCLUDING BACKFILLING IN LAYERS WITH COVERING LAYER OF SAND AROUND THE CABLE WARNING TAPE AND TILES/BRICKS COMPACTION AND MAKING GOOD AS PER PAK PWD SPECIFICATIONS. | MTR | 6500 | ||
| 416 | SH7 | PROVIDING AND LAYING OF 4 CORE 25MM2 PVC INSULATED AND PVC SHEATHED 1900/3300 VOLTS GRADE CIRCULAR STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE IN A PROPER CABLE TRENCH BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING TILES AS PER PAK PWD SPECIFICATION. | MTR | 1500 | ||
| 417 | SH7 | PROVIDING AND LAYING OF 4 CORE 50MM2 PVC INSULATED AND PVC SHEATHED 1900/3300 VOLTS GRADE CIRCULAR STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE IN A PROPER CABLE TRENCH BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING TILES AS PER PAK PWD SPECIFICATION. | MTR | 4000 | ||
| 418 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 10MM2. | MTR | 200 | ||
| 419 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 16MM2. | MTR | 11180 | ||
| 420 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 25MM2. | MTR | 210 | ||
| 421 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 35MM2. | MTR | 150 | ||
| 422 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 50MM2. | MTR | 110 | ||
| 423 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 70MM2. | MTR | 110 | ||
| 424 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 95MM2. | MTR | 100 | ||
| 425 | SH7 | PROVIDING AND LAYING 4 CORE PVC INSULATED AND PVC SHEATHED 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR ARMORED UNDERGROUND LT CABLE BURIED IN THE GROUND DULY COVERED WITH SAND AND WARNING CABLE TILES AS PER PAK PWD SPECIFICATION - 120MM2. | MTR | 100 | ||
| 426 | SH7 | PROVIDING AND LAYING HT 11 KV 3 CORE STRANDED COPPER CONDUCTOR XLPE INSULATED CU TAPE SCREENED PVC BEDDED AND PVC SHEATHED ARMORED CABLE LAID IN EXISTING ALL KIND OF PIPES CABLE DUCT CHANNELS ETC AS PER PAK PWD SPECIFICATION - 50MM2. | MTR | 150 | ||
| 427 | SH7 | PROVIDING AND LAYING HT 11 KV 3 CORE STRANDED COPPER CONDUCTOR XLPE INSULATED CU TAPE SCREENED PVC BEDDED AND PVC SHEATHED ARMORED CABLE LAID IN EXISTING ALL KIND OF PIPES CABLE DUCT CHANNELS ETC AS PER PAK PWD SPECIFICATION - 95MM2. | MTR | 150 | ||
| 428 | SH7 | PROVIDING AND FIXING INDOOR/OUTDOOR 3 CORE 11KV XLPE HEAT SHRINK TERMINATION ENDS KIT COMPLETE IN ALL RESPECT AS REQUIRED - 50MM2 TO 95MM2. | JOBS | 6 | ||
| 429 | SH7 | PROVIDING INSTALLATION AND COMMISSIONING OF OUTDOOR WATER TIGHT TYPE 30KVA 2000/415VOLTS 50HZ TRANSFORMER INCLUDING MAKING CONNECTIONS AND TESTING ON LOAD COMPLETE. | NOS | 5 | ||
| 430 | SH7 | PROVIDING INSTALLATION AND COMMISSIONING OF OUTDOOR WATER TIGHT TYPE 200 KVA 415/2000 VOLTS 50HZ TRANSFORMER INCLUDING MAKING CONNECTIONS AND TESTING ON LOAD COMPLETE. | NOS | 1 | ||
| 431 | SH7 | PROVIDING INSTALLATION AND COMMISSIONING OF OUTDOOR WATER TIGHT TYPE 150 KVA 415/2000 VOLTS 50HZ TRANSFORMER INCLUDING MAKING CONNECTIONS AND TESTING ON LOAD COMPLETE. | NOS | 1 | ||
| 432 | SH7 | PROVIDING FIXING AND COMMISSIONING INDOOR/POLE MOUNTED STEPDOWN 11000/400 VOLTS THREE PHASE 50HZ TRANSFORMER AS PER ELECTRICITY CODE COMPLETE IN ALL RESPECT - 400 KVA. | NOS | 1 | ||
| 433 | SH7 | PROVIDING FIXING AND COMMISSIONING INDOOR/POLE MOUNTED STEPDOWN 11000/400 VOLTS THREE PHASE 50HZ TRANSFORMER AS PER ELECTRICITY CODE COMPLETE IN ALL RESPECT - 630 KVA. | NOS | 2 | ||
| 434 | SH7 | PROVIDING AND FIXING HT 11 KV INDOOR/OUTDOOR TYPE FUSE D LINK/CUT OFF FUSE ASSEMBLY SET OF THREE PIECES COMPLETE WITH FUSE FITTED ON ANGLE IRON BASE FRAME AS REQUIRED. | JOBS | 3 | ||
| 435 | SH7 | PROVIDING AND ERECTING LT MS TUBULAR POLE 30 FEET LONG IN THE GROUND 5FT DEEP AND MAKING PCC FOUNDATION 1:3:6 RATIO 2FT HEIGHT FROM GROUND LEVEL DULY PLASTERED INCLUDING ACCESSORIES AND INTERCONNECTION. | JOBS | 370 | ||
| 436 | SH7 | SUPPLY AND INSTALLATION OF 2 FEET 2MM THICK GI SINGLE ARM MOUNTING BRACKET. | NOS | 10 | ||
| 437 | SH7 | SUPPLY AND INSTALLATION OF 2 FEET 2MM THICK GI DOUBLE ARM MOUNTING BRACKET. | NOS | 350 | ||
| 438 | SH7 | SUPPLY AND INSTALLATION OF 2 FEET 2MM THICK GI FOUR ARM MOUNTING BRACKET. | NOS | 10 | ||
| 439 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF FLOOD LIGHTS IP66 INCLUDING DRIVER HAVING NEUTRAL WHITE/COOL WHITE COLOUR 90-110 LM/WATTS EFFICIENCY 0.9 OR ABOVE POWER FACTOR 20000-25000 HOURS LIFE CYCLE INCLUDING CONNECTION - 90-100 WATTS. | NOS | 100 | ||
| 440 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF FLOOD LIGHTS IP66 INCLUDING DRIVER HAVING NEUTRAL WHITE/COOL WHITE COLOUR 90-110 LM/WATTS EFFICIENCY 0.9 OR ABOVE POWER FACTOR 20000-25000 HOURS LIFE CYCLE INCLUDING CONNECTION - 140-160 WATTS. | NOS | 550 | ||
| 441 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF STREET/ROAD LIGHTS IP65 INCLUDING DRIVER HAVING NEUTRAL WHITE/COOL WHITE COLOUR 90-110 LM/WATTS EFFICIENCY 0.9 OR ABOVE POWER FACTOR 20000-25000 HOURS LIFE CYCLE INCLUDING CONNECTION - 90-100 WATTS. | NOS | 50 | ||
| 442 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF STREET/ROAD LIGHTS IP65 INCLUDING DRIVER HAVING NEUTRAL WHITE/COOL WHITE COLOUR 90-110 LM/WATTS EFFICIENCY 0.9 OR ABOVE POWER FACTOR 20000-25000 HOURS LIFE CYCLE INCLUDING CONNECTION - 140-160 WATTS. | NOS | 140 | ||
| 443 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF FLOODLIGHTS IP66 INCLUDING DRIVER HAVING NEUTRAL WHITE/COOL WHITE COLOUR 110-120 LM/WATTS EFFICIENCY 0.9 OR ABOVE POWER FACTOR 40000-50000 HOURS LIFE CYCLE INCLUDING CONNECTION - 300 WATTS. | NOS | 24 | ||
| 444 | SH7 | PROVIDING FABRICATION AND INSTALLATION OF HOT DIPPED GALVANIZED POLYGONAL MAST UP TO 25 METERS HEIGHT INCLUDING MID PLATFORM HEAD PLATFORM CLIMBING LADDERS SAFETY LOOPS BASE PLATE ANCHOR BOLTS AND STIFFENERS AS PER DRAWING AND SPECIFICATION. | JOBS | 2 | ||
| 445 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED UNIDIRECTIONAL INSET APPROACH LIGHT COMPLETE WITH PRISM GASKET CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 5 | ||
| 446 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED UNIDIRECTIONAL ELEVATED APPROACH LIGHT COMPLETE WITH FRANGIBLE COUPLING POLE/BASE ASSEMBLY CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 19 | ||
| 447 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED UNIDIRECTIONAL INSET THRESHOLD LIGHT COMPLETE WITH PRISM GASKET CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 12 | ||
| 448 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED BIDIRECTIONAL INSET THRESHOLD/RUNWAY END LIGHT COMPLETE WITH GREEN/RED FILTERS PRISM GASKET CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 12 | ||
| 449 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED BIDIRECTIONAL INSET RUNWAY EDGE LIGHT COMPLETE WITH PRISM GASKET CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 6 | ||
| 450 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED BI-DIRECTIONAL ELEVATED RUNWAY EDGE LIGHT COMPLETE WITH FRANGIBLE COUPLING OPTICAL SYSTEM CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 134 | ||
| 451 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED OMNIDIRECTIONAL ELEVATED TAXIWAY EDGE LIGHT COMPLETE WITH FRANGIBLE COUPLING OPTICAL SYSTEM CABLE TERMINATION CALIBRATION AND ALL ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOBS | 50 | ||
| 452 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 45 W ISOLATING TRANSFORMER RATED 6.6A/6.6A 50/60 HZ COMPLETE WITH PRIMARY AND SECONDARY CONNECTIONS EARTHING MOUNTING AND ALL ACCESSORIES SUITABLE FOR SERIES AIRFIELD LIGHTING CIRCUITS. | JOBS | 62 | ||
| 453 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 65 W ISOLATING TRANSFORMER RATED 6.6A/6.6A 50/60 HZ COMPLETE WITH PRIMARY AND SECONDARY CONNECTIONS EARTHING MOUNTING AND ALL ACCESSORIES SUITABLE FOR SERIES AIRFIELD LIGHTING CIRCUITS. | JOBS | 188 | ||
| 454 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF ISOLATION TRANSFORMER RATED 200 W PRIMARY CURRENT 6.6 A SECONDARY CURRENT 6.6 A FREQUENCY 50/60 HZ COMPLETE WITH AL CORE CONSTRUCTION AND ALL NECESSARY ACCESSORIES SUITABLE FOR OPERATION WITH ICAO COMPLIANT AIRFIELD LIGHTING SYSTEMS. | JOBS | 8 | ||
| 455 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF LED PRECISION APPROACH PATH INDICATOR PAPI LIGHT 04 COMPLETE UNIT COMPLETE WITH OPTICAL ASSEMBLY FRANGIBLE MOUNTING AIMING AND CALIBRATION MECHANISM AND ALL NECESSARY ACCESSORIES CONFORMING TO ICAO ANNEX 14 AND FAA STANDARDS. | JOB | 1 | ||
| 456 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 8 INCH ALUMINUM SHALLOW BASE FOR INSET AIRFIELD LIGHTING FIXTURES 135 MM HEIGHT WITH 100 MM CENTRE HOLE COMPLETE WITH O-RING GASKET MOUNTING SCREWS GROUNDING SCREW AND ALL NECESSARY ACCESSORIES. | JOBS | 11 | ||
| 457 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 12 INCH ALUMINUM SHALLOW BASE FOR INSET AIRFIELD LIGHTING FIXTURES 150 MM HEIGHT WITH 100 MM CENTRE HOLE COMPLETE WITH O-RING GASKET MOUNTING STUDS GROUNDING SCREW AND ALL NECESSARY ACCESSORIES. | JOBS | 24 | ||
| 458 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 5 KVA CONSTANT CURRENT REGULATOR CCR AIR-COOLED MICROPROCESSOR-CONTROLLED MODULAR TYPE INCORPORATING FIVE BRIGHTNESS STEPS LOCAL AND REMOTE CONTROL FACILITIES AND ALL NECESSARY PROTECTIONS CONFORMING TO FAA AND ICAO STANDARDS. | JOBS | 4 | ||
| 459 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 7.5 KVA CONSTANT CURRENT REGULATOR CCR AIR-COOLED MICROPROCESSOR-CONTROLLED MODULAR TYPE INCORPORATING FIVE BRIGHTNESS STEPS LOCAL AND REMOTE CONTROL FACILITIES AND ALL NECESSARY PROTECTIONS CONFORMING TO FAA AND ICAO STANDARDS. | JOBS | 6 | ||
| 460 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF 15 KVA CONSTANT CURRENT REGULATOR CCR AIR-COOLED MICROPROCESSOR-CONTROLLED MODULAR TYPE INCORPORATING FIVE BRIGHTNESS STEPS LOCAL AND REMOTE CONTROL FACILITIES AND ALL NECESSARY PROTECTIONS CONFORMING TO FAA AND ICAO STANDARDS. | JOBS | 2 | ||
| 461 | SH7 | PROVIDING SUPPLYING LAYING TESTING AND COMMISSIONING OF 6 MM2 SINGLE-CORE AIRFIELD LIGHTING AFL PRIMARY CABLE 5 KV GRADE XLPE INSULATED STRANDED COPPER CONDUCTOR SCREENED AND PVC/PE SHEATHED SUITABLE FOR 6.6 A SERIES LIGHTING CIRCUITS CONFORMING TO ICAO AND FAA STANDARDS. | MTR | 35000 | ||
| 462 | SH7 | PROVIDING SUPPLYING LAYING TESTING AND COMMISSIONING OF 4 MM2 2-CORE AIRFIELD LIGHTING AFL SECONDARY CABLE COPPER CONDUCTOR WITH POLYCHLOROPRENE PCP INSULATION/SHEATH SUITABLE FOR CONNECTION BETWEEN ISOLATION TRANSFORMER AND AIRFIELD LIGHTING FIXTURES CONFORMING TO ICAO AND FAA STANDARDS. | MTR | 2100 | ||
| 463 | SH7 | SUPPLYING AND DRAWING OF 6MMSQ SINGLE CORE PVC INSULATED WIRE IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. | MTR | 6000 | ||
| 464 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF PRIMARY CONNECTOR KIT KD500 SUITABLE FOR 5 KV 6.6 A AIRFIELD LIGHTING AFL SERIES PRIMARY CABLE COMPRISING MOLDED PLUG AND RECEPTACLE ASSEMBLY WATERTIGHT INSULATED CONNECTORS AND ALL NECESSARY HARDWARE. | JOBS | 242 | ||
| 465 | SH7 | PROVIDING SUPPLYING AND INSTALLATION OF L-867 HOT-DIP GALVANIZED DEEP BASE ISOLATION TRANSFORMER HOUSING FABRICATED FROM HEAVY-DUTY GALVANIZED STEEL 12-INCH DIAMETER AND 18-INCH DEPTH COMPLETE WITH COVER PLATE MOUNTING STUDS UPVC CONDUIT EXCAVATION CONCRETE FOUNDATION EARTHING AND ALL ASSOCIATED ACCESSORIES CONFORMING TO FAA STANDARDS. | JOBS | 242 | ||
| 466 | SH7 | PROVIDING SUPPLYING INSTALLATION TESTING AND COMMISSIONING OF SECONDARY CONNECTOR KIT MALE AND FEMALE KD501 AND KD502 SUITABLE FOR AIRFIELD LIGHTING AFL SECONDARY CABLE CONNECTION BETWEEN THE ISOLATION TRANSFORMER AND LIGHTING FIXTURE COMPLETE WITH MOLDED WATERTIGHT CONNECTORS AND ALL NECESSARY HARDWARE CONFORMING TO FAA AND ICAO STANDARDS. | JOBS | 254 | ||
| 467 | SH7 | PROVIDING CORE CUTTING FIXING INSTALLATION TESTING AND COMMISSIONING OF 8-INCH INSET AIRFIELD LIGHTING SHALLOW BASE INCLUDING CORE DRILLING OF EXISTING PAVEMENT POSITIONING AND ALIGNMENT GROUTING WITH APPROVED NON-SHRINK EPOXY/CEMENTITIOUS GROUT REINSTATEMENT OF SURROUNDING PAVEMENT CONFORMING TO ICAO AND FAA STANDARDS. | JOBS | 31 | ||
| 468 | SH7 | PROVIDING CORE CUTTING FIXING INSTALLATION TESTING AND COMMISSIONING OF 12-INCH INSET AIRFIELD LIGHTING SHALLOW BASE INCLUDING CORE DRILLING OF EXISTING PAVEMENT POSITIONING AND ALIGNMENT GROUTING WITH APPROVED NON-SHRINK EPOXY/CEMENTITIOUS GROUT RESTORATION OF PAVEMENT CONFORMING TO ICAO AND FAA STANDARDS. | JOBS | 165 | ||
| 469 | SH7 | PROVIDING SLOT CUTTING 25 MM WIDE AND UP TO 100 MM DEEP IN EXISTING PAVEMENT INCLUDING CUTTING CLEANING LAYING OF AIRFIELD LIGHTING AFL CABLE INSTALLATION OF BACKER ROD FILLING WITH APPROVED NON-SHRINK GROUT/SEALANT SURFACE FINISHING RESTORATION OF PAVEMENT CONFORMING TO ICAO AND FAA STANDARDS. | MTR | 200 | ||
| 470 | SH7 | PROVIDING SUPPLYING AND INSTALLATION OF AIRFIELD LIGHTING AFL CABLE ROUTE MARKERS MANUFACTURED FROM REINFORCED PRECAST CONCRETE COMPLETE WITH ENGRAVED AFL CABLE IDENTIFICATION EXCAVATION CONCRETE FOUNDATION ALIGNMENT FIXING BACKFILLING AND ALL NECESSARY HARDWARE INSTALLED AT REQUIRED INTERVALS CONFORMING TO ICAO AND FAA STANDARDS. | JOBS | 446 | ||
| 471 | SH7 | PROVIDING AND INSTALLATION OF RUNWAY/TAXIWAY GUIDANCE SIGN BOARD FACE SIZE 2100 MM X 600 MM X 210 MM LOCALLY FABRICATED 14 SWG ALUMINUM SHEET FRAME MADE WITH 1-1/4IN ALUMINUM ANGLE FRAME DULY POWDER COATED SINGLE FACED WITH 5 MM THICK ACRYLIC SHEET WITH 3M VINYL PASTING INTERNALLY ILLUMINATED BY LED TYPE LIGHTS TO BE RUN ON 6.6A CCR CIRCUIT. | JOBS | 2 | ||
| 472 | SH7 | PROVIDING AND INSTALLATION OF RUNWAY/TAXIWAY GUIDANCE SIGN BOARD FACE SIZE 1200 MM X 600 MM X 210 MM LOCALLY FABRICATED 14 SWG ALUMINUM SHEET FRAME MADE WITH 1-1/4IN ALUMINUM ANGLE FRAME DULY POWDER COATED SINGLE FACED WITH 5 MM THICK ACRYLIC SHEET WITH 3M VINYL PASTING INTERNALLY ILLUMINATED BY LED TYPE LIGHTS TO BE RUN ON 6.6A CCR CIRCUIT. | JOBS | 3 | ||
| 473 | SH7 | PROVIDING AND INSTALLATION OF RUNWAY/TAXIWAY GUIDANCE SIGN BOARD FACE SIZE 2700 MM X 800 MM X 210 MM LOCALLY FABRICATED 14 SWG ALUMINUM SHEET FRAME MADE WITH 1-1/4IN ALUMINUM ANGLE FRAME DULY POWDER COATED DOUBLE FACED WITH 5 MM THICK ACRYLIC SHEET WITH 3M VINYL PASTING INTERNALLY ILLUMINATED BY LED TYPE LIGHTS TO BE RUN ON 6.6A CCR CIRCUIT. | JOBS | 2 | ||
| 474 | SH7 | FABRICATING/MAKING 1.5FT X 1.5FT X 4FT RCC FOUNDATION PADS FOR INSTALLATION OF GUIDANCE SIGN BOARDS INCLUDING NECESSARY GROUND WORK COMPLETE AS PER SITE REQUIREMENT. | JOBS | 8 | ||
| 475 | SH7 | PROVIDING AND LAYING D CLASS 50MM UPVC CONDUIT 2INCH DIA WITH ALL SPECIALS FITTING INCLUDING MAKING GOOD THE DAMAGES AS PER ORIGINAL COMPLETE. | MTR | 444 | ||
| 476 | SH7 | PROVIDING AND INSTALLATION OF 3 METERS X 19 MM DIA COPPER EARTH ROD ELECTRODE BURIED UNDER GROUND ALONG WITH SUITABLE COPPER CLAMPS NUTS/BOLTS AND MAKING CONNECTIONS INCLUDING TESTING COMPLETE. | JOBS | 40 | ||
| 477 | SH7 | PROVIDING AND LAYING OF 10MM2 STRANDED BARE COPPER CONDUCTOR FOR COUNTERPOISE IN THE EXISTING CABLE TRENCH ENSURING PROPER SPACING AS PER ICAO/FAA SPECIFICATIONS COMPLETE AS REQUIRED. | MTR | 8000 | ||
| 478 | SH7 | PROVIDING AND FIXING 4IN DIA UPVC PIPE D CLASS AND SPECIALS ETC OF APPROVED MAKE AND QUALITY WITH SPECIALS AND CLAMPS ETC. | RFT | 4081 | ||
| 479 | SH7 | EXCAVATION FOR FOUNDATION TRENCHES AND DRAINS IN STRATA OF CONGLOMERATIONS OF GRAVEL AND BOULDERS BY HAMMERING CHISELING AND JUMPER WORK INCLUDING STACKING OF SERVICEABLE AND UNSERVICEABLE MATERIALS SEPARATELY LEAD UP TO ONE CHAIN AND LIFT UP TO 5 FEET. | 100CFT | 3855 | ||
| 480 | SH7 | PROVIDING AND LAYING 1:3:6 CEMENT CONCRETE SOLID BLOCK MASONRY MACHINE MADE MORE THAN 6 INCHES THICK USING GRADED SCREENED BAJRI 3/4 INCH AND DOWN GAUGE SET IN CEMENT MORTAR 1:5 IN FOUNDATION BASEMENT AND PLINTH INCLUDING SCAFFOLDING RAKING OUT JOINTS AND CURING COMPLETE. | 100CFT | 132 | ||
| 481 | SH7 | 1/4IN THICK CEMENT PLASTER 1:4 ON SOFFITS OF CEILING CANTILEVER SLABS SIDES AND SOFFITS OF BEAMS ETC IN FIRST FLOOR INCLUDING MAKING EDGES CORNERS AND CURING COMPLETE. | 100SFT | 180 | ||
| 482 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF MONOCRYSTALLINE A GRADE TIER I HIGH EFFICIENCY IEC CERTIFIED SOLAR PANEL INCLUDING CABLING MAKING CONNECTIONS COMPLETE. | WATTS | 500000 | ||
| 483 | SH7 | PROVIDING AND FIXING OF GALVANIZED RUST FREE 14 GAUGE SOLID DESIGN FRAME FOR SOLAR PANEL COMPLETE. | NOS | 800 | ||
| 484 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF HYBRID ONGRID INVERTER INCLUDING NECESSARY CABLES MAKING CONNECTIONS WITH LOCKING ARRANGEMENTS COMPLETE - 50 KVA. | NOS | 10 | ||
| 485 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 10 AMP TO 20 AMP. | NOS | 25 | ||
| 486 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 25 AMP. | NOS | 25 | ||
| 487 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 40 AMP. | NOS | 25 | ||
| 488 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 50 AMP. | NOS | 25 | ||
| 489 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 10 AMP TO 20 AMP. | NOS | 25 | ||
| 490 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 32 AMP. | NOS | 25 | ||
| 491 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 40 AMP TO 50 AMP. | NOS | 25 | ||
| 492 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF SINGLE POLE DC CIRCUIT BREAKER FIXED ON EXISTING BOARD INCLUDING INTERCONNECTIONS - 63 AMP. | NOS | 25 | ||
| 493 | SH7 | PROVIDING LAYING FIXING TESTING AND COMMISSIONING SINGLE-CORE 6 MM2 DC SOLAR CABLE RATED UP TO 1500V DC MANUFACTURED WITH TINNED COPPER CONDUCTOR DOUBLE INSULATED LSZH FLAME RETARDANT AND UV WEATHER RESISTANT CABLE LAID IN SURFACE OR CONCEALED PVC CONDUITS INCLUDING CABLE TIES LUGS MC4 CONNECTORS GLANDING CRIMPING TERMINATION COMPLETE. | MTR | 4200 | ||
| 494 | SH7 | SUPPLY AND FIXING 12IN X 4IN MS CABLE TRAY PERFORATED 18 SWG COMPLETE WITH COVER OF 20 SWG INCLUDING PAINTING AND SUPPORTING SYSTEM. | MTR | 250 | ||
| 495 | SH7 | SUPPLY AND FIXING OF 6IN X 4IN MS CABLE TRAY PERFORATED 18 SWG COMPLETE WITH COVER OF 20 SWG INCLUDING PAINTING AND SUPPORTING SYSTEM. | MTR | 150 | ||
| 496 | SH7 | PROVIDING INSTALLATION TESTING AND COMMISSIONING OF RECESSED SPOT LIGHTS INCLUDING DRIVER HAVING WARM/NEUTRAL WHITE/COOL WHITE COLOUR 80 LM/WATT EFFICIENCY 0.9 OR ABOVE POWER FACTOR 15000-20000 HOURS LIFE CYCLE INCLUDING CONNECTION - 3 WATTS. | NOS | 8 | ||
| 497 | SH7 | WIRING FOR LIGHT POINT WITH 1.5 MM2 SINGLE CORE PVC INSULATED WIRE COPPER CONDUCTOR IN 20 MM DIA UPVC CONDUIT RECESSED IN THE WALL OR COLUMN ROOF ETC INCLUDING 1 MM2 SINGLE CORE PVC INSULATED WIRE AS ECC AS REQUIRED. | POINT | 5 | ||
| 498 | SH7 | PROVIDING AND FIXING 6/10 AMPS FLUSH TYPE SP PIANO SWITCH FITTED ON GIVEN SHEET OR ALL KIND OF BOARD INCLUDING CONNECTION AS REQUIRED. | EACH | 5 | ||
| 499 | SH7 | PROVIDING AND FIXING FLAME PROOF FITTING 20 MM ET TAPPED ENTRY CI BODY GREY PAINTED WITH HEAVY GLASS CEMENTED TO FIXED RING STRONG WIRE GUARD AND LAMP HOLDER WITH TERMINAL CHAMBER SUITABLE FOR 60/100 W LAMP. | EACH | 5 | ||
| 500 | SH7 | PROVIDING AND FIXING DISTRIBUTION BOARD STEEL SHEET FLAME PROOF OF REQUIRED SIZE WITH HINGED COVER HARD DRAWN COPPER BUS BARS MOUNTED ON INSULATED FRAMES COMPLETE WITH MAIN AND BRANCH CABLES SOCKETS AND TERMINALS ENAMEL PAINT INSIDE AND BLACK OUTSIDE 500 V 200 A 4 BARS 400 MM HEIGHT. | EACH | 5 | ||
| 501 | SH7 | PROVIDING AND FIXING 6 TO 32 AMPS SP MCCB FIXED ON EXISTING BOARD INCLUDING INTER-CONNECTION AS REQUIRED. | EACH | 5 | ||
| 502 | SH7 | PROVIDING AND FIXING 6 TO 63 AMPS DP MCCB FIXED ON EXISTING BOARD INCLUDING INTER-CONNECTION AS REQUIRED. | EACH | 5 | ||
| 503 | SH7 | PROVIDING AND FIXING EARTHING SET COMPLETE WITH 8 SWG COPPER CONDUCTOR SUPPLY AND FIXING. | EACH | 2 | ||
| 504 | SH8 | WIRING FOR LIGHT OR FAN POINT WITH 1.5 mm2 SINGLE CORE, PVC INSULATED WIRE COPPER CONDUCTOR WIRE IN 20 mm (3/4in) DIA UPVC CONDUIT RECESSED IN THE WALL OR COLUMN, ROOF ETC. INCLUDING 1mm2 SINGLE CORE PVC INSULATED WIRE AS ECC AS REQUIRED. | POINTS | 1600 | ||
| 505 | SH8 | EXTENSION/ADDITIONAL WIRING FOR LIGHT, FAN OR CALL BELL POINT CONTROLLED WITH SAME SWITCH WITH 1.5mm2 PVC INSULATED WIRE IN 20 mm (3/4in) DIA UPVC CONDUIT RECESSED IN THE WALL OR COLUMN, INCLUDING 1mm2 PVC INSULATED WIRE AS ECC AS REQUIRED. | POINTS | 1500 | ||
| 506 | SH8 | SUPPLY & DRAWING OF 2 x 2.5mm2, SINGLE CORE, PVC INSULATED WIRE INCLUDING 1mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED (P+N+E) | METERS | 16000 | ||
| 507 | SH8 | SUPPLY & DRAWING OF 2 x 4mm2, SINGLE CORE, PVC INSULATED WIRE INCLUDING 1.5mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 11000 | ||
| 508 | SH8 | SUPPLY & DRAWING OF 2 x 6mm2, SINGLE CORE, PVC INSULATED WIRE INCLUDING 2.5mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 200 | ||
| 509 | SH8 | WIRING FOR SUB-MAIN WITH 4 x 4mm2, PVC INSULATED WIRE 300/500VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 1.5mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 310 | ||
| 510 | SH8 | WIRING FOR SUB-MAIN WITH 4 x 6mm2, PVC INSULATED WIRE 300/500VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 2.5mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 3360 | ||
| 511 | SH8 | WIRING FOR SUB-MAIN WITH 4x10mm2, PVC INSULATED WIRE 300/500VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 2.5mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ALL KINDS OF EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 423 | ||
| 512 | SH8 | WIRING FOR SUB-MAIN WITH 4x16 mm2, PVC INSULATED WIRE 450/750VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 4mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ANY EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 200 | ||
| 513 | SH8 | WIRING FOR SUB-MAIN WITH 4x25mm2, PVC INSULATED WIRE 450/750VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 4mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ANY EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 170 | ||
| 514 | SH8 | WIRING FOR SUB-MAIN WITH 4x35mm2, PVC INSULATED WIRE 450/750 VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 6mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ANY EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 150 | ||
| 515 | SH8 | WIRING FOR SUB-MAIN WITH 4x50mm2, PVC INSULATED WIRE 450/750 VOLTS GRADE, SINGLE CORE, STRANDED COPPER CONDUCTOR WIRE INCLUDING 6mm2 PVC INSULATED WIRE SINGLE CORE WIRE AS ECC IN ANY EXISTING OR GIVEN CONDUIT/CABLE DUCT AS REQUIRED. (P+N+E) | METERS | 100 | ||
| 516 | SH8 | SUPPLY & FIXING 25mm (1in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC FITTED ON SURFACE AS REQUIRED. | METERS | 1200 | ||
| 517 | SH8 | SUPPLY & FIXING 40mm (1 1/2in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC FITTED ON SURFACE AS REQUIRED. | METERS | 1000 | ||
| 518 | SH8 | SUPPLY & FIXING 50mm (2in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC FITTED ON SURFACE AS REQUIRED. | METERS | 1000 | ||
| 519 | SH8 | SUPPLY & FIXING 25mm (1in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC RECESSED IN THE WALL OR COLUMN AS REQUIRED. | METERS | 5800 | ||
| 520 | SH8 | SUPPLY & FIXING 40mm (1 1/2in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC RECESSED IN THE WALL OR COLUMN AS REQUIRED. | METERS | 9000 | ||
| 521 | SH8 | SUPPLY & FIXING 50mm (2in) DIA UPVC CONDUIT WITH ALL ESPECIAL SUCH AS BENDS, SOCKETS, JUNCTION ETC RECESSED IN THE IN THE WALL OR FLOOR AS REQUIRED. | METERS | 9000 | ||
| 522 | SH8 | PROVIDING & FIXING OF 50X50mm UPVC DUCT FITTED ON SURFACE AS REQUIRED BY SITE INCHARGE. | METERS | 200 | ||
| 523 | SH8 | PROVIDING & FIXING OF 100X100mm UPVC DUCT FITTED ON SURFACE AS REQUIRED BY SITE INCHARGE. | METERS | 200 | ||
| 524 | SH8 | PROVIDING & FIXING OF 150X150mm UPVC DUCT FITTED ON SURFACE AS REQUIRED BY SITE INCHARGE. | METERS | 200 | ||
| 525 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED / SURFACE MOUNTED PROJECT / PROFESSIONAL SERIES CEILING LIGHTS / DOWNLIGHTS INCLUDING DRIVER HAVING WARM/NEUTRAL WHITE/COOL WHITE COLOUR, 100-110 LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWER FACTOR, 40000-50000 HOURS LIFECYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 11-13 WATTS | NOS | 600 | ||
| 526 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED / SURFACE MOUNTED PROJECT / PROFESSIONAL SERIES CEILING LIGHTS / DOWNLIGHTS INCLUDING DRIVER HAVING WARM/NEUTRAL WHITE/COOL WHITE COLOUR, 100-110 LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWER FACTOR, 40000-50000 HOURS LIFECYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 16-18 WATTS | NOS | 1500 | ||
| 527 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED / SURFACE MOUNTED PROJECT / PROFESSIONAL SERIES CEILING LIGHTS / DOWNLIGHTS INCLUDING DRIVER HAVING WARM/NEUTRAL WHITE/COOL WHITE COLOUR, 100-110 LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWER FACTOR, 40000-50000 HOURS LIFECYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 22-24 WATTS | NOS | 150 | ||
| 528 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED / SURFACE MOUNTED PROJECT / PROFESSIONAL SERIES CEILING LIGHTS / DOWNLIGHTS INCLUDING DRIVER HAVING WARM/NEUTRAL WHITE/COOL WHITE COLOUR, 100-110 LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWER FACTOR, 40000-50000 HOURS LIFECYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 30-34 WATTS | NOS | 100 | ||
| 529 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF RECESSED/ SURFACE MOUNTED LED PANEL LIGHT INCLUDING DRIVER, HAVING WARM/ NEUTRALWHITE /COOL WHITE COLOUR, 80-100LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWERFACTOR, 20000-25000 HOURS LIFE CYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 38-40 WATTS (2 x 2) | NOS | 250 | ||
| 530 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF LED BATTEN LIGHTS INCLUDING DRIVER, HAVING WARM / NEUTRAL WHITE /COOL WHITE COLOUR, 90-100 LM/WATTS EFFICIENCY, 0.9 OR ABOVE POWER FACTOR, 20000-25000 HOURS LIFE CYCLE, INCLUDING CONNECTION, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 18-20 WATTS | NOS | 250 | ||
| 531 | SH8 | PROVIDING & INSTALLING 140 Cm (56in) SWEEP CEILING FAN WITH BLADES, CANOPY, STANDARD LENGTH OF DOWN ROD INCLUDING CONNECTION WITH 14.0076in FLEXIBLE WIRE COMPLETE AS REQUIRED. (WITHOUT REGULATOR) PAK, ROYAL, GFC, YOUNAS, MILLAT. | NOS | 250 | ||
| 532 | SH8 | PROVIDING & INSTALLING FALSE CEILING FAN (BOX FAN) WITH REMOTE, 24in (2 x 2) SIZE INCLUDING CONNECTIONS, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE (VOLDAM / PAK / ROYAL) | NOS | 250 | ||
| 533 | SH8 | PROVIDING & INSTALLING 45 Cm (18in) SWEEP WALL BRACKET FAN COMPLETE WITH BLADES, REGULATOR & PULLING CORD SWITCH, FITTED ON WALL OR COLUMN WITH GI CLIP INCLUDING CONNECTION AS REQUIRED. PAK, ROYAL, GFC, YOUNAS, MILLAT | NOS | 50 | ||
| 534 | SH8 | PROVIDING & INSTALLING 30 Cm (12in) SWEEP, METALLIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FITTED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076in FLEXIBLE WIRE COMPLETE AS REQUIRED PAK, ROYAL, GFC, YOUNAS, MILLAT. | NOS | 20 | ||
| 535 | SH8 | PROVIDING & INSTALLING 60 Cm (24in) SWEEP, METALLIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FIXED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076in FLEXIBLE WIRE COMPLETE AS REQUIRED PAK, ROYAL, GFC, YOUNAS, MILLAT. | NOS | 12 | ||
| 536 | SH8 | PROVIDING & INSTALLING 25 Cm (10in) SWEEP, PLASTIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FIXED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076in FLEXIBLE WIRE COMPLETE AS REQUIRED PAK, ROYAL, GFC, YOUNAS, MILLAT. | NOS | 66 | ||
| 537 | SH8 | PROVIDING & INSTALLING 30 Cm (12in) SWEEP, PLASTIC BODY EXHAUST FAN COMPLETE WITH BLADES, MOTOR, ETC FIXED IN EXISTING HOLE INCLUDING CONNECTION WITH 14/.0076in FLEXIBLE WIRE COMPLETE AS REQUIRED PAK, ROYAL, GFC, YOUNAS, MILLAT. | NOS | 60 | ||
| 538 | SH8 | PROVIDING & FIXING 10 AMPS POLYCARBONATE FLAME RETARDANT S.P SWITCH WITH FANCY REQUIRED GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 1900 | ||
| 539 | SH8 | PROVIDING & FIXING 10 AMPS POLYCARBONATE FLAME RETARDANT 2-PIN SWITCH SOCKET UNIT ( UNIVERSAL) WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 1000 | ||
| 540 | SH8 | PROVIDING & FIXING 15 AMPS POLYCARBONATE FLAME RETARDANT 3-PIN SWITCH SOCKET UNIT WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 400 | ||
| 541 | SH8 | PROVIDING & FIXING 10/15 AMPS POLYCARBONATE FLAME RETARDANT 2-PIN SCHUKO SOCKET UNIT(GR-EARTH PIN) WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 40 | ||
| 542 | SH8 | PROVIDING & FIXING LIGHT DIMMER POLYCARBONATE FLAME RETARDANT WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 355 | ||
| 543 | SH8 | PROVIDING & FIXING POLYCARBONATE FLAME RETARDANT DATA SOCKET UNIT 8 CONTACT CAT-5 WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 250 | ||
| 544 | SH8 | PROVIDING & FIXING POLYCARBONATE FLAME RETARDANT TELEPHONE SOCKET 4 CONTACT SINGLE 2 LINE WITH FANCY GANG PLATE FIXED ON DIE FABRICATED, POWDER COATED METAL BOARD RECESSED IN WALL OR COLUMN INCLUDING CONNECTION AS REQUIRED. (SCHNEIDER / PHILIPS) | NOS | 250 | ||
| 545 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF ONLINE UPS, WITH STANDARD BACKUP OF 15-20 MINUTES, SUITABLE FOR OPERATION AT 220/240 VOLTS, 50HZ, SINGLE PHASE AC SUPPLY, INCLUDING CONNECTIONS, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 1 KVA | NOS | 3 | ||
| 546 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF ONLINE UPS, WITH STANDARD BACKUP OF 15-20 MINUTES, SUITABLE FOR OPERATION AT 220/240 VOLTS, 50HZ, SINGLE PHASE AC SUPPLY, INCLUDING CONNECTIONS, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 2 KVA | NOS | 3 | ||
| 547 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF ONLINE UPS, WITH STANDARD BACKUP OF 15-20 MINUTES, SUITABLE FOR OPERATION AT 220/240 VOLTS, 50HZ, SINGLE PHASE AC SUPPLY, INCLUDING CONNECTIONS, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 3 KVA | NOS | 6 | ||
| 548 | SH8 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF ONLINE UPS, 10KVA CAPACITY, WITH STANDARD BACKUP OF 15-20 MINUTES, 3 PHASE IN AND 3 PHASE OUT, SUITABLE FOR OPERATION AT 380/400VOLTS, 50HZ, AC SUPPLY, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. | NOS | 5 | ||
| 549 | SH8 | PROVIDING & FIXING CUBICAL TYPE METAL SHEET VERMIN PROTECTED LT PANEL BOARD AS PER DRAWING WITH LOCKING ARRANGEMENT DULY POWDER COATED I/C ALL FASTENING DEVICES AND ELECTRICAL WIRE/ LEADS FOR INTERNAL CONNECTION COMPLETE AS REQUIRED. | SFT | 650 | ||
| 550 | SH8 | PROVIDING & FIXING 6 TO 32 AMPS, S.P MCCB FIXED ON EXISTING BOARD, I/C INTER-CONNECTION AS REQUIRED. | NOS | 950 | ||
| 551 | SH8 | 6-32 AMPS DP MCCB. | NOS | 250 | ||
| 552 | SH8 | PROVIDING & FIXING 10 TO 60 AMPS,( HIGH BREAKING CAPACITY) T.P MCCB FIXED ON EXISTING BOARD, I/C INTER-CONNECTION AS REQUIRED. | NOS | 70 | ||
| 553 | SH8 | PROVIDING & FIXING 75 TO 100 AMPS,( LOW BREAKING CAPACITY) T.P MCCB FIXED ON EXISTING BOARD, I/C INTER-CONNECTION AS REQUIRED. | NOS | 30 | ||
| 554 | SH8 | PROVIDING & FIXING 250 TO 400 AMPS,( HIGH BREAKING CAPACITY) T.P CIRCUIT BREAKER FIXED ON EXISTING BOARD, I/C INTER-CONNECTION AS REQUIRED. | NOS | 20 | ||
| 555 | SH8 | PROVIDING & FIXING 400 TO 630 AMPS,( HIGH BREAKING CAPACITY) T.P CIRCUIT BREAKER FIXED ON EXISTING BOARD, I/C INTER-CONNECTION AS REQUIRED. | NOS | 20 | ||
| 556 | SH8 | PROVIDING & FIXING 400 TO 630 AMPS,(ADJUSTABLE- HIGH BREAKING CAPACITY) 4 POLE CIRCUIT BREAKER FIXED ON EXISTING BOARD, I/C INTERCONNECTION AS REQUIRED. | NOS | 4 | ||
| 557 | SH8 | PROVIDING & FIXING 630 TO 1200 AMPS, (ADJUSTABLE- HIGH BREAKING CAPACITY) 4 POLE CIRCUIT BREAKER FIXED ON EXISTING BOARD, I/C INTER CONNECTION AS REQUIRED. | NOS | 4 | ||
| 558 | SH8 | PROVIDING & FIXING 10 TO 60 AMPS, 4 POLE, THREE PHASE BUS BAR STRIP FITTED IN GIVEN DISTRIBUTION BOARD COMPLETE WITH BUS BAR INSULATOR, SCREWS, BOLTS ETC AS REQUIRED. | NOS | 55 | ||
| 559 | SH8 | PROVIDING & FIXING 70 TO 100 AMPS, 4 POLE, THREE PHASE BUS BAR STRIP FITTED IN GIVEN DISTRIBUTION BOARD COMPLETE WITH BUS BAR INSULATOR, SCREWS, BOLTS ETC AS REQUIRED. | NOS | 60 | ||
| 560 | SH8 | PROVIDING & FIXING 160 TO 200 AMPS, 4 POLE, THREE PHASE BUS BAR STRIP FITTED IN GIVEN DISTRIBUTION BOARD COMPLETE WITH BUS BAR INSULATOR, SCREWS, BOLTS ETC AS REQUIRED. | NOS | 20 | ||
| 561 | SH8 | PROVIDING & FIXING 400 AMPS, 4 POLE, THREE PHASE BUS BAR STRIP SET (STANDARD SIZE) FITTED IN SUITABLE SIZE METALLIC SHEET STEEL BOX WITH HINGED TYPE FRONT DOOR DULY PAINTED AND FIXED ON EXISTING BOARD I/C CONNECTION AS REQUIRED. | NOS | 20 | ||
| 562 | SH8 | PROVIDING & FIXING PILOT LAMP SET FITTED ON EXISTING BOARD I/C CONNECTION AS REQUIRED. | SETS | 60 | ||
| 563 | SH8 | VOLT METER 96 mm x 96 mm | NOS | 60 | ||
| 564 | SH8 | AMPERE METER 96 mm x 96 mm CT OPERATED 150 TO 1000 AMP | NOS | 60 | ||
| 565 | SH8 | CURRENT TRANSFORMER 200/5A | NOS | 180 | ||
| 566 | SH8 | PROVIDING AND FIXING EARTHING SET WITH 2ftx2ftx1/4in COPPER PLATE BURIED IN THE GROUND AT A DEPTH OF 12 FEET OR LESS IF WATER COMES OUT FROM THE GROUND LEVEL (WITH SALT AND CHARCOAL, OR EARTHING CHEMICAL POWDER) ETC MAKING THE PIT 12 FEET DEEP BY EXCAVATION OF ALL TYPE OF SOIL (EXCEPT SOFT OR HARD ROCK) I/C FIXING OF 8SWG COPPER WIRE IN 1/2in G.I CONDUIT COMPLETE IN ALL RESPECT AS REQUIRED. | JOBS | 60 | ||
| 567 | SH8 | PROVIDING AND FIXING 1in DIAMETER 3FT LONG LIGHTING COPPER ROD WITH FIVE SPIKES AND BALLS ON ITS HEAD AS REQUIRED. | JOBS | 100 | ||
| 568 | SH8 | PROVIDING AND FIXING 1-1/2in x 1/3in THICK COPPER STRIP WITH SUITABLE SADDLE AT 12in INTERVALS COMPLETE AS REQUIRED. | METERS | 2000 | ||
| 569 | SH8 | WIRING OF CCTV CAMERA WITH UTP CAT-6 IN EXISTING PVC CONDUIT/DUCT I/C CONNECTORS COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE (VOICE + DATA) | METERS | 15000 | ||
| 570 | SH8 | PROVIDING, FIXING AND INSTALLING POE GIGA BIT SWITCHES, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. - 8 PORT POE SWITCH | JOBS | 32 | ||
| 571 | SH8 | PROVIDING, FIXING AND INSTALLING POE GIGA BIT SWITCHES, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. - 16 PORT POE SWITCH | JOBS | 32 | ||
| 572 | SH8 | PROVIDING, SUPPLYING, INSTALLATION, FITTING, FIXING AND COMMISSIONING OF 4 CORE SINGLE MODE FIBER OPTICS CABLE IN GIVEN EXISTING PVC CONDUIT, BOX CONDUIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. | METERS | 500 | ||
| 573 | SH8 | PROVIDING, SUPPLYING, INSTALLATION, FITTING, FIXING AND COMMISSIONING OF 8 CORE SINGLE MODE FIBER OPTICS CABLE IN GIVEN EXISTING PVC CONDUIT, BOX CONDUIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE | METERS | 500 | ||
| 574 | SH8 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF MEDIA CONVERTER, USED FOR DATA CONVERSION FROM FIBER OPTIC TO CAT-6 ETHERNET CABLE, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. | NOS | 64 | ||
| 575 | SH8 | PROVIDING, SUPPLYING, INSTALLATION, FITTING, FIXING AND COMMISSIONING OF ODF WITH UP & DOWN FIBER CONNECTIVITY WITH REQUIRED PROGRAMMING AS NEEDED, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 8 PORT POE SWITCH | NOS | 40 | ||
| 576 | SH8 | PROVIDING AND INSTALLATION OF ILLUMINATED SIGNBOARDS FOR LOUNGES IN BOTH URDU AND ENGLISH WORDS BEST MATERIAL (MS SHEET 18 SWG), LASER/FIBRE CUTTING OF LETTERS & SIGNS, ACRYLIC SHEET 4 mm YELLOW, POWDER COATING, COMPLETE 3D BENDING SCREWLESS SIGN, LED /SMD INJECTED MODULES, WATER PROOF POWER SUPPLY, 3D LIGHTING LATEST TYPE APPROVED COLOUR AND PATTERN, SINGLE AND DOUBLE FACED SIGNS COMPLETE IN ALL RESPECT AS PER INSTRUCTIONS OF ENGINEER INCHARGE. | SFT | 250 | ||
| 577 | SH8 | PROVIDING AND INSTALLATION OF MS 3D ILLUMINATED SIGNBOARDS FABRICATED WITH MS CHANNEL 3/4in x 1in (18-20SWG) STRUCTURE INCLUDING MS LETTER HAVING 4in THICKNESS OF 18-20 SWG POWDER COATED APPROVED COLOR, PLASTIC / ACRYLIC LETTER SHEET 3mm PURE YELLOW ILLUMINATED WITH 400 WATTS, SMD / LED INJECTED MODULES 5730 / 5050 COOL WHITE COLOR WITH SUITABLE WATER PROOF WIRING / POWER SUPPLY. JOB ALSO INCLUDES INVISIBLE ANGLE IRON STRUCTURE 2inx2in OF 6mm WITH WELDED SUPPORT FITTED ON HEAVY GAUGE IRON STRUCTURE AS PER SITE REQUIREMENT COMPLETE IN ALL RESPECTS WITH TESTING AND AS PER INSTRUCTIONS OF ENGINEER IN-CHARGE | SFT | 480 | ||
| 578 | SH8 | PROVIDING & FIXING OF UNIVERSAL MOUNTED LED BASED EXIT SIGN IMPORTED MAKE WITH DOUBLE / SINGLE FACE CONFIGURATION, 220VAC, 02 WATTS, COMPLETE WITH RECHARGEABLE NI-CAD BATTERY I/C MAKING CONNECTION ETC. COMPLETE IN ALL RESPECTS AS PER SATISFACTION OF ENGINEER IN-CHARGE | NOS | 31 | ||
| 579 | SH8 | PROVIDING & INSTALLATION OF 45 LITRES / HOUR CAPACITY WATER COOLER WITH BRAND NEW COMPRESSOR AND CONDENSOR, PRIME COPPER WRAPPED STEEL TANK AND ELECTRIC FAN MOTOR, PRIME GRADE INSULATION, STAINLESS STEEL FULLY DIE MADE BODY WITH BLACK COLOR ETC. COMPLETE IN ALL RESPECTS AS PER SATISFACTION OF ENGINEER IN-CHARGE | NOS | 5 | ||
| 580 | SH8 | PROVIDING & FIXING 12in x 4in MS CABLE TRAY PERFORATED 18 SWG COMPLETE WITH COVER OF 20 SWG INCLUDING PAINTING AND SUPPORTING SYSTEM | METERS | 250 | ||
| 581 | SH8 | PROVIDING & FIXING OF 6in x 4in MS CABLE TRAY PERFORATED 18 SWG COMPLETE WITH COVER OF 20 SWG INCLUDING PAINTING AND SUPPORTING SYSTEM | METERS | 150 | ||
| 582 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL 02 ZONE FIRE ALARM CONTROL PANEL SURFACE /RECESSED MOUNTING TYPE WITH FULL SWITCHING PROGRAMMING CAPABILITIES, SYSTEM SUITABLE OPERATION OF 230 VOLTS 50HZ WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER WITH BATTERY BACKUP COMPLIES WITH ALLIED COMPONENTS APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED | JOBS | 3 | ||
| 583 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL 04 ZONE FIRE ALARM CONTROL PANEL SURFACE /RECESSED MOUNTING TYPE WITH FULL SWITCHING PROGRAMMING CAPABILITIES, SYSTEM SUITABLE OPERATION OF 230 VOLTS 50HZ WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER WITH BATTERY BACKUP COMPLIES WITH ALLIED COMPONENTS APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 2 | ||
| 584 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL 08 ZONE FIRE ALARM CONTROL PANEL SURFACE /RECESSED MOUNTING TYPE WITH FULL SWITCHING PROGRAMMING CAPABILITIES, SYSTEM SUITABLE OPERATION OF 230 VOLTS 50HZ WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER WITH BATTERY BACKUP COMPLIES WITH ALLIED COMPONENTS APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED | JOB | 1 | ||
| 585 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL SMOKE DETECTOR, WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER/ DRAWING WITH ALLIED COMPONENTS APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 180 | ||
| 586 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL HEAT DETECTOR, WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER/ DRAWING WITH ALLIED COMPONENTS APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 25 | ||
| 587 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF MANUAL CALL POINT BREAK GLASS TYPE WITH SPARE GLASS WITH ALLIED COMPONENTS WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER/ DRAWING ETC APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 50 | ||
| 588 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL WALL SOUNDER WITH ALLIED COMPONENTS WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER/ DRAWING ETC APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 50 | ||
| 589 | SH8 | PROVIDING, FIXING, TESTING AND COMMISSIONING OF CONVENTIONAL 6in BELL WITH ALLIED COMPONENTS WITH FULL FUNCTIONALITY AS PER SPECIFICATION OF MANUFACTURER/ DRAWING ETC APPROVED MAKE OR AS APPROVED BY THE ENGINEER IN-CHARGE AS REQUIRED. | JOBS | 50 | ||
| 590 | SH8 | PROVIDING, FIXING, TWO CORE, 1.5mm, FIRE RESISTANT CABLE, MINIMUM FIRE RATING OF 2 HOUR, LAID IN CONDUIT (25mm DIA), COMPLETE IN ALL RESPECT, AS APPROVED BY THE ENGINEER IN-CHARGE. | METERS | 3500 | ||
| 591 | SH9 | CONDUCTING ELECTRIC RESISTIVITY SURVEY AT DIFFERENT LOCATIONS TO CONFIGURE THE SUBSURFACE LITHOLOGIES/POSSIBILITY OF GROUND WATER SUITABLE FOR DRILLING TUBE WELL. | JOBS | 4 | ||
| 592 | SH9 | DRILLING OF TRIAL BORE IN SHINGLE GRAVEL AND ROCK INCLUDING SINKING AND WITH DRAWING OF CASING PIPES 6in - 10in DIA GROUND LEVEL TO 250 Rft | RFT | 250 | ||
| 593 | SH9 | EXCEEDING 250 Rft | RFT | 170 | ||
| 594 | SH9 | CONVERSION OF TRIAL BORE IN SHINGLE GRAVEL AND ROCK INCLUDING SINKING AND WITH DRAWING OF CASING PIPES 15in - 18in DIA GROUND LEVEL TO 250 Rft | RFT | 250 | ||
| 595 | SH9 | EXCEEDING 250 Rft | RFT | 170 | ||
| 596 | SH9 | FURNISHING SAMPLES OF WATER FROM BORE HOLE. | SETS | 2 | ||
| 597 | SH9 | PROVIDING AND INSTALLING PVC BAIL/END PLUG IN TUBE WELL BORE HOLE 2 ft LONG & 10in DIA CLASS E COMPLETE AS REQUIRED. | NOS | 2 | ||
| 598 | SH9 | PROVIDING AND INSTALLING 10in DIA U PVC BLIND PIPE BSS CLASS E IN TUBE WELL BORE HOLE INCLUDING SOCKETS AND SALVENT ETC COMPLETE AS REQUIRED AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED | RFT | 200 | ||
| 599 | SH9 | PROVIDING AND INSTALLING 10in DIA U PVC STRAINER BSS CLASS E IN TUBE WELL BORE HOLE INCLUDING SOCKETS AND SALVENT ETC COMPLETE AS REQUIRED AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED | RFT | 640 | ||
| 600 | SH9 | SHROUDING WITH GRADED PEA GRAVEL INTO THE SPACE BETWEEN BORE HOLE AND BLIND PIPE/STRAINER. | CFT | 1105 | ||
| 601 | SH9 | ELECTRIC/VIDEO LOGGING OF SUCCESSFUL BORE HOLE FOR PROPER PLACEMENT OF STRAINER/BLIND PIPE ETC COMPLETE AS REQUIRED. | JOBS | 2 | ||
| 602 | SH9 | TESTING DEVELOP AND STERILIZE OF TUBE WELL THROUGH COMPRESSOR UPTO 1.5 CUSECS DISCHARGE IN ACCORDANCE WITH APPROVED PROCEDURE UPTO DURATION OF 72 HOURS AS REQUIRED BY THE ENGINEER. | JOBS | 2 | ||
| 603 | SH9 | PROVIDING & LAYING IN SITU 1:2:4 CEMENT CONCRETE USING SCREEN GRADED BAJRI IN FOUNDATION AND PLINTH I/C FORM WORK, RODDING, COMPACTING, CURING ETC. | CFT | 144 | ||
| 604 | SH9 | PROVIDING & FIXING CENTRIFUGAL PUMPING SET COMPLETE WITH AC 5 HP 2850/2900 RPM 380/400V 50 CYCLE 3 PHASE AC MOTOR WITH CENTRIFUGAL PUMP HAVING SUCTION & DISCHARGE 2 x 1 1/2in COUPLED ON A COMMON BASE PLATE AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 605 | SH9 | PROVIDING & FIXING CENTRIFUGAL PUMPING SET COMPLETE WITH AC 10 HP 2850/2900 RPM 380/400V 50 CYCLE 3 PHASE AC MOTOR WITH CENTRIFUGAL PUMP HAVING SUCTION & DISCHARGE 4in x 3in COUPLED ON A COMMON BASE PLATE AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 606 | SH9 | PROVIDING & FIXING CENTRIFUGAL PUMPING SET COMPLETE WITH AC 15 HP 2850/2900 RPM 380/400V 50 CYCLE 3 PHASE AC MOTOR WITH CENTRIFUGAL PUMP HAVING SUCTION & DISCHARGE 4in x 3in COUPLED ON A COMMON BASE PLATE AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 607 | SH9 | PROVIDING & FIXING SUBMERSIBLE PUMPING SET COMPRISING OF SUBMERSIBLE PUMP WITH 5 HP 2850/2900 RPM, 3 PHASE, 400 V, 50 HZ, AC ELECTRIC MOTOR CAPABLE TO DISCHARGE 1800-2500 US GPH (GALLONS PER HOUR) OF CLEAR WATER AT HEAD OF 250 TO 300 ft, INCLUDING ERRECTION CLAMP, CABLE CLAMP, NON RETURN VALVE, MOTOR CONTROL UNIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 608 | SH9 | PROVIDING & FIXING SUBMERSIBLE PUMPING SET COMPRISING OF SUBMERSIBLE PUMP WITH 10 HP 2850/2900 RPM, 3 PHASE, 400 V, 50 HZ, AC ELECTRIC MOTOR CAPABLE TO DISCHARGE 1800-2500 US GPH (GALLONS PER HOUR) OF CLEAR WATER AT HEAD OF 250 TO 300 ft, INCLUDING ERRECTION CLAMP, CABLE CLAMP, NON RETURN VALVE, MOTOR CONTROL UNIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 609 | SH9 | PROVIDING & FIXING SUBMERSIBLE PUMPING SET COMPRISING OF SUBMERSIBLE PUMP WITH 15 HP 2850/2900 RPM, 3 PHASE, 400 V, 50 HZ, AC ELECTRIC MOTOR CAPABLE TO DISCHARGE 1800-2500 US GPH (GALLONS PER HOUR) OF CLEAR WATER AT HEAD OF 250 TO 300 ft, INCLUDING ERRECTION CLAMP, CABLE CLAMP, NON RETURN VALVE, MOTOR CONTROL UNIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 610 | SH9 | PROVIDING & FIXING SUBMERSIBLE PUMPING SET (KSB/GRUNDFOS/HMA) COMPRISING OF SUBMERSIBLE PUMP WITH 3 HP 2850/2900 RPM, 3 PHASE, 400 V, 50 HZ, AC ELECTRIC MOTOR CAPABLE TO DISCHARGE 800-900 US GPH (GALLONS PER HOUR) OF CLEAR WATER AT HEAD OF 250 TO 320 ft, INCLUDING ERRECTION CLAMP, CABLE CLAMP, NON RETURN VALVE, MOTOR CONTROL UNIT, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE AS REQUIRED. | NO | 1 | ||
| 611 | SH9 | PROVIDING & FIXING MANUAL OPERATED STAR DELTA STARTER SUITABLE FOR 3-10 HP AC.3 PHASE 50 CYCLE SUPPLY UP TO 12/25 AMPS TRIP RATING ON A PREPARED BOARD. | NOS | 6 | ||
| 612 | SH9 | WIRING FOR SUB-MAIN WITH 3 CORE, 6 mm2, STRANDED COPPER CONDUCTOR, PVC INSULATED & PVC SHEATHED CIRCULAR / FLAT CABLE IN EXISTING CONDUIT FITTED ON SURFACE / UNDERGROUND AS REQUIRED. | METERS | 250 | ||
| 613 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF SPLIT TYPE WALL MOUNTED AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 0.9 TON - 1.0 TON (10800 BTU - 12000 BTU) | JOBS | 50 | ||
| 614 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF SPLIT TYPE WALL MOUNTED AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 1.5 TON - 1.6 TON (18000 BTU - 19500 BTU) | JOBS | 150 | ||
| 615 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF SPLIT TYPE WALL MOUNTED AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 1.9 TON - 2 TON (22800 BTU - 24000 BTU) | JOBS | 25 | ||
| 616 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF SPLIT TYPE WALL MOUNTED AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 2.2 TON - 2.5 TON (26000 BTU - 30000 BTU) | JOBS | 25 | ||
| 617 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF CASSETTE TYPE AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 1.9 TON - 2 TON (22800 BTU - 24000 BTU) | JOBS | 30 | ||
| 618 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF CASSETTE TYPE AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 3.8 TON - 4.0 TON (45600 BTU - 48000 BTU) | JOBS | 25 | ||
| 619 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF FLOOR STANDING AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 2 TON - 2.3 TON (24000 BTU - 28000 BTU) | JOBS | 10 | ||
| 620 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF FLOOR STANDING AIR CONDITIONER, HEAT & COOL, IN THE SPECIFIED PLACE. THE JOB INCLUDES CONNECTION OF COPPER PIPING OF OUT DOOR UNIT FITTED ON ROOF OR ANGLE IRON FRAME, MAKING INTER CONNECTION OF THE UNIT WITH SUITABLE SIZES OF WIRE ALSO PIPING FOR CONDENSED WATER ETC AS REQUIRED APPROVED MAKE (IMPORTED). - 3.8 TON - 4.0 TON (45600 BTU - 48000 BTU) | JOBS | 20 | ||
| 621 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF REFRIGERANT COPPER PIPE, 22 GAUGE WITH ALL TYPE OF FITTINGS LIKE, ELBOW, CLAMPING, AERO FLEX INSULATION, WRAPPING TAPE, ETC COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 1/4in | FTS | 2000 | ||
| 622 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF REFRIGERANT COPPER PIPE, 22 GAUGE WITH ALL TYPE OF FITTINGS LIKE, ELBOW, CLAMPING, AERO FLEX INSULATION, WRAPPING TAPE, ETC COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 1/2in | FTS | 2000 | ||
| 623 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF REFRIGERANT COPPER PIPE, 22 GAUGE WITH ALL TYPE OF FITTINGS LIKE, ELBOW, CLAMPING, AERO FLEX INSULATION, WRAPPING TAPE, ETC COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 3/8in | FTS | 2000 | ||
| 624 | SH9 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF REFRIGERANT COPPER PIPE, 22 GAUGE WITH ALL TYPE OF FITTINGS LIKE, ELBOW, CLAMPING, AERO FLEX INSULATION, WRAPPING TAPE, ETC COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 5/8in | FTS | 2000 | ||
| 625 | SH9 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF STANDBY 1500 RPM, DIESEL GENERATING SET, SUITABLE FOR 400/415 VOLTS, 3-PHASE, 50HZ, AC SUPPLY, WITH CANOPY, INCLUDING CONTROL WIRING, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 440 KVA (400 KVA PRIME RATINGS) | JOB | 1 | ||
| 626 | SH9 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF STANDBY 1500 RPM, DIESEL GENERATING SET, SUITABLE FOR 400/415 VOLTS, 3-PHASE, 50HZ, AC SUPPLY, WITH CANOPY, INCLUDING CONTROL WIRING, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 700 KVA (640 KVA PRIME RATINGS) | JOBS | 2 | ||
| 627 | SH9 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF 400 VOLTS, 3-PHASE, 3 POLE, ATS PANEL, WITH MOR, DULY POWDER COATED, PAINTED, HAVING MAGNETIC CONTACTOR, MECHANICAL INTERLOCKING, EMERGENCY STOP SYSTEM, ATS MODULE, BATTERY CHARGER, AUXILIARY RELAYS, VOLTMETER, AMPERE METER, FREQUENCY METER, SELECTOR SWITCH, INDICATION LIGHTS, COPPER BUS BAR, TIMERS, INCLUDING WIRING, LOCKING ARRANGEMENTS, ETC, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 400 KVA | JOB | 1 | ||
| 628 | SH9 | PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF 400 VOLTS, 3-PHASE, 3 POLE, ATS PANEL, WITH MOR, DULY POWDER COATED, PAINTED, HAVING MAGNETIC CONTACTOR, MECHANICAL INTERLOCKING, EMERGENCY STOP SYSTEM, ATS MODULE, BATTERY CHARGER, AUXILIARY RELAYS, VOLTMETER, AMPERE METER, FREQUENCY METER, SELECTOR SWITCH, INDICATION LIGHTS, COPPER BUS BAR, TIMERS, INCLUDING WIRING, LOCKING ARRANGEMENTS, ETC, COMPLETE IN ALL RESPECT AS APPROVED BY THE ENGINEER INCHARGE. - 600 KVA | JOBS | 2 | ||
| 629 | SH9 | PROVIDING & FIXING 4 CORE, PVC INSULATED & PVC SHEATHED, 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR, UNARMOURED, L.T CABLE FIXED ON SURFACE WITH HEAVY GAUGE GI FLAT STRIP SADDLE AT SUITABLE DISTANCE AS PER PAK. P.W.D SPECIFICATION AS REQUIRED. - 185 mm2 | METERS | 310 | ||
| 630 | SH9 | PROVIDING & FIXING 4 CORE, PVC INSULATED & PVC SHEATHED, 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR, UNARMOURED, L.T CABLE FIXED ON SURFACE WITH HEAVY GAUGE GI FLAT STRIP SADDLE AT SUITABLE DISTANCE AS PER PAK. P.W.D SPECIFICATION AS REQUIRED. - 240 mm2 | METERS | 200 | ||
| 631 | SH9 | PROVIDING & FIXING 4 CORE, PVC INSULATED & PVC SHEATHED, 600/1000 VOLTS GRADE WITH STRANDED COPPER CONDUCTOR, UNARMOURED, L.T CABLE FIXED ON SURFACE WITH HEAVY GAUGE GI FLAT STRIP SADDLE AT SUITABLE DISTANCE AS PER PAK. P.W.D SPECIFICATION AS REQUIRED. - 300 mm2 | METERS | 180 | ||
| 632 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 16 mm2 TO 25 mm2 | NOS | 750 | ||
| 633 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 35 mm2 TO 50 mm2 | NOS | 30 | ||
| 634 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 70 mm2 TO 95 mm2 | NOS | 30 | ||
| 635 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 120 mm2 TO 150 mm2 | NOS | 20 | ||
| 636 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 185 mm2 TO 240 mm2 | NOS | 20 | ||
| 637 | SH9 | MAKING TERMINATION OF 3 OR 4 CORE ARMOURED / UN-ARMOURED COPPER CONDUCTOR, PVC X PVC L.T CABLE INCLUDING PROVIDING & FIXING PROPER LUGS, ETC COMPLETE IN ALL RESPECT AS REQUIRED. - 300 mm2 | NOS | 14 | ||
| 638 | SH9 | VENTILATION SYSTEM: EXPLOSION-PROOF EXHAUST FANS AND AIR VENTS (UAV BUNKERS) COMPLETE AS PER SPECIFICATIONS AND DIRECTIONS OF THE ENGINEER. | NOS | 4 | ||
| 639 | SH9 | DEHUMIDIFIER: TO MAINTAIN LOW HUMIDITY INSIDE BUNKER (UAV BUNKERS) COMPLETE AS PER SPECIFICATIONS AND DIRECTIONS OF THE ENGINEER. | NOS | 2 | ||
| 640 | SH9 | FIRE SUPPRESSION: FIRE EXTINGUISHERS (DCP) AS PER SAFETY CODES (UAV BUNKERS) | NOS | 4 | ||
| 641 | TOTAL ESTIMATED COST | JOB | 1 | 7343223931 | ||
| GRAND TOTAL: | Rs 7,343,223,931.00 |
The contractor shall execute all procurement, installation, testing, and commissioning works across the following nine sub-heads:
1. Rehabilitation of Airside Pavements (SH 1)
Earthworks and Sub Base: Demolishing existing bituminous pavements, stripping topsoil, compacting natural subgrade, and laying granular sub base reinforced with biaxial HDPE geogrids and geocells.
Paving and Markings: Constructing polymer modified asphalt base and wearing courses, laying PQC for taxiway links and aprons, sealing rigid joints with jet fuel resistant sealant, installing airside drainage pipes, and applying FAA compliant reflective airfield markings.
2. Access Road (SH 2)
Roadway Construction: Clearing the alignment, constructing compacted borrow embankments, laying aggregate base courses, and paving with plant mixed asphaltic wearing course.
Drainage and Furniture: Building reinforced concrete roadside drains and pipe culverts, applying thermoplastic road markings, and installing reflective caution signboards.
3. Ancillary Civil Infrastructure (SH 3)
Structural and Architectural Works: Constructing Grade 60 steel reinforced concrete foundations, frames, roof slabs, and overhead water tanks, alongside brick masonry, plastering, terrazzo and marble flooring, gypsum ceilings, Deodar wood doors, uPVC or aluminium windows, and stainless steel railings.
Plumbing and Sewerage: Fitting washroom sanitary ware, kitchen cabinetry, grease traps, brick manholes, uPVC waste stacks, and galvanized iron water mains.
4. Renovation of Passenger Terminal Building (SH 4)
Refurbishment and Finishes: Stripping damaged tiles, plaster, and paint, re securing door frames, applying fresh plaster and non slip tiling, repainting exteriors, and installing gypsum, fiberglass, Plaster of Paris, and MDF false ceilings.
Glazing and Accessibility: Fitting anodized aluminium doors and tinted glass sliding windows, upgrading washrooms, and constructing a concrete wheelchair ramp with stainless steel handrails.
5. Public Health Engineering (SH 5)
Tube Wells and Pumping: Drilling deep boreholes using reverse rotary percussion methods, installing mild steel blind pipes and stainless steel V wire screens, gravel shrouding, sterilizing wells, and commissioning high head submersible pumps with chlorination units.
Water and Sewerage Networks: Trenching and laying PE 100, PPR, and galvanized iron water distribution lines with isolation valves, alongside constructing masonry manholes, soakage pits, and reinforced concrete sewer lines.
6. Security Infrastructure (SH 6)
UAV Bunkers and Hardening: Excavating and constructing reinforced concrete semi underground bunkers with bituminous waterproofing, camouflage earth cover, and blast resistant steel doors.
Perimeter Barriers and Access: Deploying and sand filling UV stabilized HESCO defense barriers, erecting galvanized wire mesh, barbed wire, and concertina razor wire fencing, installing a motorized heavy duty steel taxiway gate, and laying hydraulically compressed concrete pavers.
7. External Electrical Infrastructure (SH 7)
Power Distribution: Trenching and laying 11 kV XLPE armored cables and underground low tension copper cables, and commissioning step down transformers and switchgear.
Airfield Lighting and Solar Plant: Installing ICAO and FAA compliant LED inset and elevated approach, threshold, runway, and taxiway lights, a PAPI system, Constant Current Regulators, isolating transformers, illuminated guidance signs, street and high mast floodlighting, and a 500 kW solar PV plant with hybrid inverters.
8. Building Electrification and Life Safety (SH 8)
Internal Power and Lighting: Installing concealed uPVC conduits, copper wiring, flame retardant switches and sockets, vermin proof distribution boards, copper plate earthing, lightning protection, online UPS systems, LED lighting fixtures, fans, and illuminated lounge signage.
IT, CCTV, and Fire Safety: Deploying CAT 6 cabling, single mode fiber optic backbones, PoE switches, conventional multi zone fire alarm panels with fire resistant cabling, smoke and heat detectors, call points, sounders, and battery backed exit signs.
9. Mechanical Works (SH 9)
Groundwater and Pumping Systems: Conducting electric resistivity surveys, drilling and video logging production boreholes, installing uPVC casing and strainers, and commissioning centrifugal and submersible pump sets.
HVAC and Standby Generation: Installing wall mounted split, ceiling cassette, and floor standing air conditioners with insulated copper piping, equipping UAV bunkers with explosion proof exhaust fans, dehumidifiers, and fire extinguishers, and commissioning canopy type standby diesel generators with Automatic Transfer Switch panels.
The Rehabilitation of Dalbandin Airport, commissioned by the Pakistan Airports Authority (PAA) in Dalbandin, Balochistan, is a comprehensive infrastructure modernization and security upgrade initiative. Designed to restore full operational readiness, elevate aviation safety, and harden perimeter defenses, the project integrates nine civil, electrical, mechanical, and public health engineering packages.
Core airside works involve the demolition and full depth reconstruction of runways, taxiways, and aprons utilizing Asphalt Concrete, and Pavement Quality Concrete (PQC) compliant with ICAO and FAA standards. Landside improvements include constructing a paved access road with drainage culverts, renovating the Passenger Terminal Building (PTB) with accessibility upgrades, and erecting reinforced ancillary support buildings. A central focus of the project is tactical and perimeter security hardening, featuring HESCO defense barriers, concertina fencing, heavy duty concrete paving, and semi underground, blast resistant Unmanned Aerial Vehicle (UAV) bunkers.
Supporting utility and electromechanical packages cover deep tube well boring, potable water supply and sewerage networks, 11 kV high tension and low tension power distribution, an ICAO Annex 14 compliant LED Airfield Ground Lighting (AGL) system, a 500 kW grid tied solar power plant, standby diesel generators, HVAC installations, and conventional fire detection and life safety systems. Together, these upgrades will establish Dalbandin Airport as a resilient, modern, and secure regional aviation facility.
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
Red Book:
© FIDIC 2017. All rights reserved.
The Conditions of Contract are the “General Conditions” which form part of the “Conditions of Contract for Construction for Building and Engineering Works Designed by the Employer (“Red book”) Second edition 2017” published by the Federation Internationale Des Ingenieurs – Conseils (FIDIC) and the following “Particular Conditions” which shall complement the General Conditions of the Contract.
The successful Bidder, upon contract award, shall be required to furnish two (02) copies of aforementioned “General Conditions” for incorporation in the Works Contract.
International Federation of Consulting Engineers (FIDIC) FIDIC
Bookshop – Box- 311 – CH – 1215 Geneva 15, Switzerland
Fax: +41 22 799 49 054
Telephone: +41 22 568 0500
E-mail: fidic@fidic.org
Website: www.fidic.org
FIDIC code: ISBN13: 978-2-88432-084-9
Particular Conditions
(Mandatory Provisions not to be amended/substituted)
The Particular Conditions (PCC) complement the General Conditions (GCC) to specify dates, contractual requirements, and special circumstances related to the Works. The PCC consists of two parts, Part A - Contract Data and Part B - Special Provisions. The provisions to be found in the Special Provisions (Particular Conditions - Part B) take precedence over the equivalent provisions found under the same Sub-Clause number(s) in the General Conditions, and the provisions of the Contract Data (Particular Conditions - Part A) take precedence over the Special Provisions (Particular Conditions - Part B).
Sub-Clause 1.1.27
Defects Notification Period (DNP): 365 Days
Sub-Clause 1.1.31
Employer's name & address: Quetta Airport (Pakistan Airports Authority (PAA)), Secretary Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Sub-Clause 1.1.35
Engineer's name & address: Abdul Mohaymin Sahito, DDS Civil HQ
HQ, Terminal I, JIAP, Karachi
Sub-Clause 1.1.84
Time for Completion: 730 days for whole of the works
Sub-Clause 1.3 (a)(ii)
Agreed method of electronic transmission: Agreed
The Electronic Transmission Methods are Email
Sub-Clause 1.3 (d)
Address of Empoyer for Communications: Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
Address of Engineer for Communications:
HQ, Terminal I, JIAP, Karachi
Sub-Clause 1.4
Contract shall be governed by the law of: Islamic Republic of Pakistan
Ruling language: English
Language for communications: English
Sub-Clause 2.1
After receiving the Letter of Acceptance, the Contractor shall be given right of access to all or part of the Site within: 15 days after Commencement Date
Sub-Clause 2.4
Employer’s financial arrangements:
Funded by Provincial Government
Sub-Clause 3.2 (e)(ii)
Engineer’s Duties and Authority: Variation resulting in an increase of the Accepted Contract Amount in excess ofone percent (1%)subject to accumulative Variations not exceeding five percent (5%)of the Accepted Contract Amount
Sub-Clause 4.2
Performance Security (as percentage of the Accepted Contract Amount in Currencies): 0%
Form of Performance Guarantee: Nil
Sub-Clause 4.2.1
List of Insurance Companies:
Insurance Company in Pakistan having at least “AA” rating from PACRA
Sub-Clause 4.7.2
period for notification of errors in the items of reference: Twenty Eight (28) days
Sub-Clause 4.19
Period of payment for temporary utilities: Each Month
Sub-Clause 5.1 (a)
Maximum allowable accumulated value of work subcontracted (as a percentage of the Accepted Contract Amount): 30 %
Sub-Clause 5.1 (b)
Parts of the Works for which subcontracting is not permitted: 40
None
Sub-Clause 6.5
Normal working hours on the Site: 09
Sub-Clause 8.3
Number of additional paper copies of programmes: 06
Sub-Clause 8.8 & 14.15(b)
Delay Damages payable for each day of delay 0.01% of the Accepted Contract Amountfor delay in completion of whole of the Works
Sub-Clause 8.8
Maximum amount of Delay Damages 10.00 % of the Accepted Contract Amount
Sub-Clause 8.14
Applicability of Incentives for Early Completion No
Sub-Clause 12.3
Percentage profit (Not more than 10%): Nil
Sub-Clause 13.4.(b)(ii)
Percentage rate to be applied to Provisional Sums for overhead charges and profit: Twenty Five percent (25%)
Sub-Clause 14.2
Total Advance Payment: Fifteen percent (15%) of the Accepted Contract Amount excluding Provisional Sums payable in the currencies and proportions in which the Accepted Contract Amount is payable
Sub-Clause 14.2.1
Advance Payment Insurance Allowed
Insurance Company in Pakistan having at least “AA” rating from PACRA
Sub-Clause 14.2.3
Percentage deductions for the repayment of the Advance Payment: Deduction shall be made at the amortization rate of 17.5 % of the value of the Works executed of each IPC as provided in paragraph (i) of Sub-Clause GCC 14.3, starting from 2nd IPC provided that the advance payment shall be completely repaid prior to the time when 90% of the Accepted Contract Amount less Provisional Sums has been certified for payment. It may be more than 17.5% in the last instalment to ensure full repayment.
Sub-Clause 14.3
Period of payment One Month
Sub-Clause 14.3(b)
Number of additional paper copies of Statements: 06
Sub-Clause 14.3 (iii)
Percentage of retention: Seven percent (7%)
Sub-Clause 14.3 (iii)
Limit of Retention Money (as a percentage of the Accepted Contract Amount): Five percent (5%)
Sub-Clause 14.5(b)(i)
Plant and Materials for payment when shipped: Plant and Materials under Bill of “Imported Plant and Materials”
Deleted. Not Applicable.
Sub-Clause 14.5(c)(i)
Plant and Materials for payment when delivered to the Site: Plant and Non Perishable Materials
Plant and Non-Perishable Materials for payment shall include: 1. Steel Reinforcement 2. Tile, Marble and Granite 3. Electric Cables
Sub-Clause 14.6.2
Minimum amount of Interim Payment Certificate (IPC): Yes
The Minimum Amount IPC is 150,000,000
[Employer to give value not exceeding one fifth of the average expected value of Interim Payment Certificate]
Sub-Clause 14.7(a)
Period of payment of Advance Payment to the Contractor: 14 days
Sub-Clause 14.7b(i)
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.6: 28 days
Sub-Clause 14.7b(ii)
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.13 (Final Payment): 56 days
Sub-Clause 14.7(c)
Period for the Employer to make final payment to the Contractor: 56 days
Sub-Clause 14.8
Financing charges for delayed payment Local Currency (PKR):
6-Month KIBOR (Offer) +3% per annum.
Foreign Currency:
USD
6-Month SOFR (Secured Overnight Financing Rate for USD) +1% per annum.
EURO
6-Month EURIBOR (EURO Interbank Offered Rate for EURO) +1% per annum.
Others
Appropriate rates +1% (for other foreign currencies, Ref. Schedule-A, A-4 to Bid).
Sub-Clause 14.11.1(b)
Number of additional paper copies of draft Final Statements: 06
[insert number of copies say six (06)]
Sub-Clause 14.15
Currencies of payment of Contract Price: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(a)(i)
Proportions or amounts of Local and Foreign currencies: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(c)
Currencies and proportions for payment of Delay Damages: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(f)
rates of exchange: as stated in the Table IV of Schedule A (If Given)
Sub-Clause 17.2(d)
Forces of nature, the risks of which are allocated to the Contractor: Nil
Sub-Clause 19.1
Permitted deductible limits:
i) insurance required for the Works: Ten percent (10%) of loss amount on each & every loss
ii) insurance required for Goods: Nil
iii) insurance required for liability for breach of professional duty: Nil
iv) insurance required against liability for fitness for purpose (if any is required): Nil
v) insurance required for injury to persons and damage to property: Nil
vi) insurance required for injury to employees: Nil
vii) other insurances required by Laws and by local practice : Nil
Periods for submission of insurance:
a) evidence of insurance: Not later than the Commencement Date
b) relevant policies: Within twenty eight (28) day from the Commencement Date
Sub-Clause 19.2.1(b)
Additional amount to be insured (as a percentage of the replacement value): 15% of the replacement value (Accepted Contract Amount)
Sub-Clause 19.2.2
Extent of insurance required for Goods: From Ex-Works (i.e., works, factory, warehouse, etc) to delivery at the Site
Amount of insurance required for Goods: Full replacement value
Sub-Clause 19.2.3(a)
Amount of insurance required for liability for breach of professional duty: Full replacement value of the Works to be designed by the Contractor
Sub-Clause 19.2.3(b)
Insurance required against liability for fitness for purpose: Yes
Sub-Clause 19.2.3
Period of insurance required for liability for breach of professional duty: Until the date of issuance of Performance Certificate
Sub-Clause 19.2.4
Amount of insurance required for injury to persons and damage to property: Injury to person and Fatal case:
in accordance with Workmen Compensation Act
Damage to Property: The Amount of Insurance Required for Person Injury is In accordance with Workmen Compensation Act
The Amount of Insurance Required for Damage to Property is In accordance with Contractor's All Risk Policy as per his assessment of the adjoining property(ies) other than the Works]
without limit to the number of incidents
Sub-Clause 19.2.6
Other insurances required by Laws and by local practice: All insurances as applicable, to the extent of execution of the project, under Federal and Provincial laws of Islamic Republic of Pakistan
Sub-Clause 21.1
Time for appointment of the DAAB: Within 28 days from the Commencement Date.
In case the Accepted Contract Amount is lesser than PKR one (01) billion, appointment of the DAAB shall be made when Dispute arises between the Parties.
Sub-Clause 21.1
The DAAB shall comprise 3
[insert either “a sole Member” or “Three Members”]
[For a Contract estimated to cost above PKR 2.5billion, the DAAB shall comprise of three members. For a Contract estimated to cost between PKR1billion and PKR2.5billion, the DAAB may comprise of three members or a sole member. For a Contract estimated to cost less than PKR1billion, a sole member is recommended.]
Sub-Clause 21.1
List of proposed members of DAAB
- proposed by Employer
Sole Member
-
-
Sub-Clause 21.2
Appointing entity (official) for DAAB members Managing Director Public Procurement Regulatory Authority (PPRA) or Chairman Pakistan Engineering Council (PEC) from the list of PEC approved arbitrators published at its website
Sub-Clause 21.6
Rules of Arbitration: PEC Rules of Conciliation and Arbitration or Pakistan Arbitration Act of 1940, if the former is inactive.
The place of Arbitration shall be in the Employer’s country: Karachi
[Insert name of city]
PartB - Special Provisions
1.1 Definitions
1.1.76 “Specification”
Following is added at the end:
“and consists of two parts i.e.,
i) “Part A - Specific Provisions”; and
ii) “Part B - Technical Provisions”.”
1.2 Interpretation
“and” is deleted from the end of sub-paragraph (i) and added at the end of sub-paragraph (j).
Sub-paragraph (k) is added:
“(k) The word “tender” is synonymous with “bid” the word tenderer with “bidder”, the words “tender documents” with “bidding documents” and “Schedule of Prices” with “Bill of Quantities”, as applicable.”
1.5 Priority of Documents
The documents listed at (a) through (k) of this Sub-Clause are deleted and substituted with the following:
(a) the Contract Agreement;
(b) the Letter of Acceptance;
(c) the Letter of Bid;
(d) the Particular Conditions Part A - Contract Data;
(e) the Particular Conditions Part B - SpecialProvisions;
(f) the General Conditions;
(g) the Specification Part A - SpecificProvisions;
(h) the Specification Part B- Technical Provisions;
(i) the Drawings;
(j) the completed Schedules to Bid includingBillof Quantities;
(k) the JV Undertaking (if the Contractor is a JV); and
(l) any other documents forming part of the Contract.
The addenda/corrigenda, if any, shall be deemed to have been incorporated at the appropriate places in the documents forming the Contract.
1.6 Contract Agreement
In the last line of the 1st paragraph the text “shall be borne by the Employer” is substituted by“ shall be reimbursed by the Employer to the Contractor”.
3.1 The Engineer
In sub-paragraph (a) the text “as defined in the Pakistan Engineering Council Act, 1975 (Act No.V of 1976)” are added after the words “professional engineer”.
3.2 Engineer’s Duties and Authority
The Engineer shall obtain the consent in writing of the Employer before taking action under the following Sub-Clauses of these Conditions:
(a) Consenting to the subcontracting of any part of the Works under Sub-Clause 5.1 [Subcontractors]
(b) Any action under Sub-Clauses 8.9 [Employer’s Suspension] and 8.12 [Prolonged Suspension]
(c) Issuance of “Taking Over Certificate” under Sub-Clause 10.1 [Taking Over the Works and Sections].
(d) Issuing the “Performance Certificate” under Sub-Clause 11.9 [Performance Certificate].
(e) Sub-Clause 13.1 [Right to Vary]: instructing a Variation, except;
(i) in an emergency situation as determined by the Engineer, or
(ii) if such a Variation would increase the Accepted Contract Amount by less than the percentage specified in the Contract Data.
(f) Sub-Clause 13.3 [Variation Procedure]: approving a proposal for Variation submitted by the Contractor in accordance with Sub-Clause 13.3.2 [Variation by Request for Proposal] or 13.2 [Value Engineering].
(g) Certifying release of second half of the Retention Money under Sub-Clause 14.9 [Release of Retention Money].
(h) Issuing Final Payment Certificate under Sub-Clause 14.13 [Issue of FPC].
(i)
-
4.2 Performance Security
4.2.1 Contractor’s Obligations
The entity issuing the Performance Security and its form shall be as under:
The Performance Security shall be, at the option of the Contractor,issuedin the prescribed form included in the Bidding Documents,by(a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistan or (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofratingas provided in Table below:
Accepted Contract Amount (In Eq. PKR million) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
In case of Joint Venture, the Performance Security shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.
Following paragraph is added at the end of this Sub-Clause:
“The amount of Performance Security shall be reducedto 50%following issue of the Taking-Over Certificate for the whole of the Works under Clause 10 of Conditions of Contract.”
4.3 Contractor’s Representative
In second paragraphthe text “professional engineer as defined in the Pakistan Engineering Council Act, 1975 (Act No. V of 1976) (having temporary licence in case of foreign engineer under Section 12 of the Pakistan Engineering Council Act, 1975 (Act No. V of 1976)” are added after the words “qualified, experienced”.
In the 3rd paragraph the words “28 days” are substituted by “14 days”. In 2nd line of 4thparagraph the text “or appoint a replacement” is substituted by “except appointment of a suitable temporary replacement is deployed at the Site”
4.4 Contractor’s Documents
4.4.2 As-Built Records
First paragraph is deleted and the text in the last paragraph is substituted with the following:
“The Contractor shall furnish to the Engineer 6 copies, one reproducible and one electronic copy(provided the Engineer has made available to the Contractor editable form of the Drawings)of all Drawings amended to conform to the Works as built.In case the Engineer does not make available to the Contractor editable form of the Drawings, the Contractor shall furnish to the Engineer as-built data for incorporation in the Drawings. Upon receipt of PDF versions of the as-built drawings prepared by the Engineer, the Contractor shall furnish to the Engineer 6copies and one reproducible of these Drawings.
The price of such Drawings shall be deemed to be included in the Contract Price.”
Following Sub-Clause is added:
4.4.4 ShopDrawings
The Contractor shall submit to the Engineer for review 3 copies of all shop and erection drawings applicable to this Contract as per provision of relevant Sub-Clause of the Contract.
Review and approval by the Engineer shall not exceed 21 days and be construed as a complete check but will indicate only that the general method of construction and detailing is satisfactory and the Engineer’s review or approval shall not relieve the Contractor of any of his responsibilities under the Contract.
4.8 Health and Safety Obligations
The following text is added at the end ofthis Sub-Clause:
In the event of work being carried out outside the normal working hours and in the event of work being carried out at night, the Contractor shall at his own cost, provide and maintain such good and sufficient light as will enable the work to proceed satisfactorily and without danger. The approaches to the Site and the Works where the night work is being carried out shall be sufficiently lighted. All arrangement adopted for such lighting shall be to the satisfaction of the Engineer.
4.20 Progress Reports
At the end of sub-paragraph (g) the word “and” is deleted and at the end of sub-paragraph (h) the full stop (.) is replaced with “;”, and the following new sub-paragraphs are added as:
(i) planned programme for the execution of the Works for next 56 days to enable the Engineer to determine its programme of inspection and testing;
(j) monthly summery of daily job record indicating weather conditions, deployment of Contractor’s Equipment, labour employment, local material procurement and material import, if any; and
(k) salient contractual and project information.
5.1 Subcontractors
Add the following text at the end of paragraph (ii):
“underSchedule to Bid”
The following is added at the end of the last paragraph of Sub-Clause 5.1:
“All subcontracts relating to the Works shall include provisions which entitle the Employer to require the subcontract to be assigned to the Employer under sub-paragraph (a) of Sub-Clause 15.2.3 [After Termination].
The Contractor shall give reasonable opportunity to contractors from Islamic Republic of Pakistan for subcontracts for the Works, and endeavour to employ such contractors as Subcontractors.”
5.2 Nominated Subcontractors
5.2.2 Objection to Nomination
In sub-paragraph (c), “and” is deleted from the end of (i);
“.” at the end of (ii) is replaced with: “, and”.
The following is then added as (iii):
“(iii) be paid only if and when the Contractor has received from the Employer payments for sums due under the Subcontract referred to under Sub-Clause 5.2.3 [Payment to nominated Subcontractors].”
6.1 Engagement of Staff and Labour
The following paragraph is added at the end of the Sub-Clause:
“The Contractor shall, to the extent practicable and reasonable, employ staff (not less than 50%) and labour (not less than 85%) with appropriate qualifications and experience from sources within the Islamic Republic of Pakistan.”
6.7 Health and Safety of Personnel
The existing text is substituted with the following:
“In order to provide for the safety, health and welfare of persons, and for prevention of damage of any kind, all operations for the purposes of or in connection with the Contract shall be carried out in compliance with the Safety Requirements of the Government of Pakistan with such modifications thereto as the Engineer may authorize or direct and the Contractor shall take or cause to be taken such further measures and comply with such further requirements as the Engineer may determine to be reasonably necessary for such purpose. The Contractor shall also provide all other medical services and appoint a health and safety officer at Site if stated in the Specifications. In case of any fatality or serious accident, the Contractor shall, in addition, notify the Engineer immediately by the quickest available means.”
6.8 Contractor’s Superintendence
Insert at the end of sub-paragraph (a) of this Sub-Clause:
"or, if not, the Contractor shall make competent interpreters available during all working hours, in a number sufficient for those persons to properly perform their superintendence duties"
The following text is added at the end of this Sub-Clause:
“The Contractor’s authorized representative and his other engineers working at site shall possess valid registration with the Pakistan Engineering Council.
The Contractor’s authorized representative at Site shall be authorized to exercise adequate administrative and financial powers on behalf of the Contractor so as to achieve completion of the Works as per the Contract.”
6.12 Key Personnel
The following is inserted at the end of the last paragraph:
“If any of the Key Personnel are not fluent in this language, the Contractor shall make competent interpreters available during all working hours in a number deemed sufficient by the Engineer.”
The following Sub-Clauses 6.13 to 6.26 are added at the end of Sub-Clause 6.12:
6.13 Foreign Personnel
The Contractor may bring in to the Country any foreign personnel who are necessary for the execution of the Works to the extent allowed by the applicable Laws. The Contractor shall ensure that these personnel are provided with the required residence visas and work permits. The Employer will, if requested by the Contractor, use all reasonable endeavours in a timely and expeditious manner to assist the Contractor in obtaining any local, state, national, or government permission required for bringing in the Contractor’s personnel.
The Contractor shall be responsible for the return of these personnel to the place where they were recruited or to their domicile. In the event of the death in the Country of any of these personnel or members of their families, the Contractor shall similarly be responsible for making the appropriate arrangements for their return or burial.
6.14 Supply of Foodstuffs
The Contractor shall arrange for the provision of a sufficient supply of suitable food as may be stated in the Specification at reasonable prices for the Contractor’s Personnel for the purposes of or in connection with the Contract.
6.15 Supply of Water
The Contractor shall, having regard to local conditions, provide on the Site an adequate supply of drinking and other water for the use of the Contractor’s Personnel.
6.16 Measures against Insect and Pest Nuisance
The Contractor shall at all times take the necessary precautions to protect the Contractor’s Personnel employed on the Site from insect and pest nuisance, and to reduce the danger to their health. The Contractor shall comply with all the regulations of the local health authorities, including use of appropriate insecticide.
6.17 Alcoholic Liquor or Drugs
The Contractor shall not, otherwise than in accordance with the Laws of the Country, import, sell, give, barter or otherwise dispose of any alcoholic liquor or drugs, or permit or allow importation, sale, gift, barter or disposal thereto by Contractor’s Personnel.
6.18 Arms and Ammunition
The Contractor shall not give, barter, or otherwise dispose of, to any person, any arms or ammunition of any kind, or allow Contractor’s Personnel to do so.
6.19 Festivals and Religious Customs
The Contractor shall respect the Country’s recognized festivals, days of rest and religious or other customs.
6.20 Funeral Arrangements
The Contractor shall be responsible, to the extent required by local regulations, for making any funeral arrangements for any of its local employees who may die while engaged upon the Works.
6.21 Forced Labour
The Contractor, including its Subcontractors, shall not employ or engage forced labour which consists of any work or service, not voluntarily performed, that is exacted from an individual under threat of force or penalty, and includes any kind of involuntary or compulsory labour, such as indentured labour, bonded labour or similar labour-contracting arrangements.
6.22 Child Labour
The Contractor, including its Subcontractors, shall not employ or engage child labour in accordance with relevant law(s) in force in Islamic Republic of Pakistan.
6.23 Employment Records of Workers
The Contractor shall keep complete and accurate records of the employment of labour at the Site. The records shall include the names, ages, genders, hours worked and wages paid to all workers. These records shall be summarized on a monthly basis and submitted to the Engineer. These records shall be included in the details to be submitted by the Contractor under Sub-Clause 6.10 [Contractor’s Records].
6.24 Workers’ Organizations
The Contractor shall comply with the relevant labour laws of Pakistan which recognize workers’ rights to form and to join workers’ organizations/Trade Union of their choosing and to bargain collectively without interference.
6.25 Non-Discrimination and Equal Opportunity
The Contractor shall not make decisions relating to the employment or treatment of Contractor’s Personnel on the basis of personal characteristics unrelated to inherent job requirements. The Contractor shall base the employment of Contractor’s Personnel on the principle of equal opportunity and fair treatment, and shall not discriminate with respect to any aspects of the employment relationship, including recruitment and hiring, compensation (including wages and benefits), working conditions and terms of employment, access to training, job assignment, promotion, termination of employment or retirement, and disciplinary practices.
Special measures of protection or assistance to remedy past discrimination or selection for a particular job based on the inherent requirements of the job shall not be deemed discrimination. The Contractor shall provide protection and assistance as necessary to ensure nondiscrimination and equal opportunity, including for specific groups such as women, persons with disabilities, migrant workers and children (of working age in accordance with Sub-Clause 6.22).
6.26 Epidemics
In the event of any out-break of illness of epidemic nature, the Contractor shall comply with and carry out such regulations, orders and requirements as may be made by the Government or the local medical or sanitary authorities for the purpose of overcoming the same.
7.7 Ownership of Plant and Materials
The following is added before the first paragraph:
“Except as otherwise provided in the Contract,”
The following is added at the end of the Sub-Clause:
"No Plant and/or Materials that is the property of the Employer shallbe removed from the Site. If it becomes necessary to:
(i) remove any item of such Plant from the Site for the purposesof repair, the Contractor shall give a Notice, with reasons, tothe Engineer requesting consent to remove the defective ordamaged item off the Site. This Notice shall clearly identifythe item of defective or damaged Plant, and shall give detailsof: the defect or damage to be repaired; the place to whichdefective or damaged item of Plant is to be taken for repair;the transportation to be used (and insurance cover for suchtransportation); the proposed inspections and testing off theSite; and the planned duration required before the repaireditem of Plant shall be returned to the Site. The Contractorshall also provide any further details that the Employer mayreasonably require; or
(ii) replace any item(s) of such Plant and/or Materials, theContractor shall give a Notice, with reasons, to the Engineerclearly identifying the item(s) of Plant and/or Materials to bereplaced, and giving details of the due date of delivery tothe Site of the replacement item(s).
Where any item of Plant and/or Materials has become the propertyof the Employer under this Sub-Clause before it has been deliveredto the Site, the Contractor shall ensure that such an item is notmoved except for its delivery to the Site.
The Contractor shall indemnify and hold the Employer harmlessagainst and from the consequences of any defect in title orencumbrance or charge (except any reasonable restrictionarising from the intellectual property rights of the manufacturer orproducer) on any item of Plant and/or Materials that has becomethe property of the Employer under this Sub-Clause."
The following Sub-Clause7.9 is added after Sub Clause 7.8:
7.9 Use of Pakistani Materials and Services
The Contractor shall, so far as may be consistent with the Contract, make the maximum use of materials, supplies, plant and equipment indigenous to or produced or fabricated in Pakistan and services available in Pakistan provided such materials, supplies, plant, equipment and services shall be of required standard.
8.1 Commencement of Works
The following is added before the first paragraph:
“After signing of the Contract Agreement by both Parties,” and thereafter the word “The” is replaced with the word “the”.
8.5 Extension of Time for Completion
The following is added after paragraph (c):
“for last five years”.
The following Sub-Clause 8.14 is added after Sub-Clause 8.13:
8.14 Incentives For Early Completion
If Contract Data does not state applicability of incentives for early completion, this Sub-Clause shall not apply.
The Contractor shall be entitled subject to Sub-Clause 20.2 [Claims for Payment and/or EOT] to bonus payment if the Works and/or each Section is completed earlier than the Time for Completion for the Works or Section (as the case may be). The amount of bonus for early completion of the Works and/or each Section shall be upto a limit and at a rate to 50% of the relevant limit and rate of delay damages prescribed in Contract Data and shall be paid for every day which shall elapse between the relevant Date of Completion of the Works or Section and the relevant Time for Completion.
For the purposes of calculating any bonus payment, the applicableTime for Completion stated in the Contract Data is fixed and noadjustments of this time by reason of granting an EOT will beallowed.
The following Sub-Clause 11.12 is added after Sub-Clause 11.11:
11.12 Supervisory Assistance During DNP
If provided under the Schedule of Prices, the Contractor shall provide supervisory assistance to the Employer during the DNP for the Works. Such supervisory assistance shall be as described in the Specification for the purpose of supporting the Employer's operation and maintenance of the Plant for the period specified in the Schedule of Prices after the Date of Completion.
12.2 Method of Measurement
The following paragraph is added at the end of the Sub-Clause:
“Summary of measured quantity for payment shall be delineated item-wise under four headsnamely; “Schedule of Prices Quantity”, “Quantity Executed To-date”, “Quantity Certified Previously” and “Net Quantity Executed under this Certificate”.
12.3 Valuation of the Works
The following text is added at the end of fifth paragraph of the Sub-Clause:
“Sum of overhead charges and profit for sub-paragraph (a) shall be Twenty Five percent (25%)”.
13.4 Provisional Sums
The following paragraph is inserted as the penultimate paragraph:
“The Provisional Sum shall be used to cover the Employer’s share of the DAAB members’ fees and expenses, in accordance with Clause 21. No prior instruction of the Engineer shall be required with respect to the work of the DAAB. The Contractor shall submit the DAAB members’ invoices and the satisfactory evidence of having paid 100% of such invoices as part of the substantiation of those Statements submitted under Sub-Clause 14.3.
13.6 Adjustments for Changes in Laws
The following paragraphsare added at the end of the Sub-Clause:
“Notwithstanding the foregoing, the Contractor shall not be entitled to an extension of time if the relevant delay has already been taken into account in the determination of a previous extension of time and such Cost shall not be separately paid if the same shall already have been taken into account in the indexing of any inputs to the Table of Adjustment Data in accordance with the provisions of Sub-Clause 13.7 [Adjustments for Changes in Cost].”
14.1 The Contract Price
The following is added at the end of the Sub-Clause:
“Notwithstanding the provisions of subparagraph (b), Contractor's Equipment, including essential spare parts, imported by the Contractor for the sole purpose of executing the Contract shall be temporarily exempt from the payment of import duties and taxes upon initial importation, provided the Contractor shall post with the customs authorities at the port of entry an approved re-export bond or bank guarantee, valid until the Time for Completion plus six months, in an amount equal to the full import duties and taxes which would be payable on the assessed imported value of such Contractor's Equipment and spare parts, and callable in the event the Contractor's Equipment is not re-exported from the Country on completion of the Contract. A copy of the bond or bank guarantee endorsed by the customs authorities shall be provided by the Contractor to the Employer upon the importation of individual items of Contractor's Equipment and spare parts. Upon re-export of individual items of Contractor's Equipment or spare parts, or upon the completion of the Contract, the Contractor shall prepare, for approval by the customs authorities, an assessment of the residual value of the Contractor's Equipment and spare part to be re-exported, based on the depreciation scale(s) and other criteria used by the customs authorities for such purposes under the provisions of the applicable Laws. Import duties and taxes shall be due and payable to the customs authorities by the Contractor on (a) the difference between the initial imported value and the residual value of the Contractor's Equipment and spare parts to re-exported; and (b) on the initial imported value of the Contractor's Equipment and spare parts remaining in the Country after completion of the Contract. Upon payment of such dues within 28 days of being invoiced, the bond or bank guarantee shall be reduced or released accordingly; otherwise the security shall be called in the full amount remaining.”
[The Employer may change or delete this Sub-Clause as per Project requirements]
14.2 Advance Payment
14.2.1 Advance Payment Guarantee
The entity issuing the Advance PaymentGuaranteeand its form shall be as under:
The Advance PaymentGuarantee shall be in the form of Guarantee issued by (a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistanor (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofrating as provided in Table below:
Accepted Contract Amount (In Eq. million PKR) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
In case of Joint Venture, the Advance PaymentGuarantee(s)shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.
14.6 Issue of IPC
14.6.1 The IPC
In the first line of the 1st paragraph the words “28 days” are substituted by “14 days”.
14.7 Payment
The words “or through crossed cheque in favour of the Contractor or JV partners. The Payment to JV partners shall be made at the request of the Joint Ventures in the ratio of their shares specified by them” are added at the end of the Sub-Clause.
14.8 Delayed Payment
In the first paragraph, third line, the words “compounded monthly” are deleted.
The text of 2nd paragraph is deleted and substituted with the following:
“The Employer shall pay to the Contractor compensation at the rate stated in the Contract Data.”
14.9 Release of Retention Money
The following is added at the end of Sub-Clause 14.9:
“Unless otherwise stated in the Contract, when the Taking-Over Certificate has been issued for the Works and the first half of the Retention Money has been certified for payment by the Engineer, the Contractor shall be entitled to substitute a guarantee, in the form annexed to the Particular Conditions or in another form approved by the Employer and issued by a schedule bank selected by the Contractor, for the second half of the Retention Money. The Contractor shall ensure that the guarantee is in the amounts and currencies of the second half of the Retention Money and is valid and enforceable until the Contractor has executed and completed the Works and remedied any defects, as specified for the Performance Security. On receipt by the Employer of the required guarantee, the Engineer shall certify, and the Employer shall pay the second half of the Retention Money. The release of the second half of the Retention Money against a guarantee shall then be in lieu of the release after the latest of the expiry dates of the Defects Notification Periods. The Employer shall return the guarantee to the Contractor within 21 days after receiving a copy of the Performance Certificate.
If the Performance Security required under Sub-Clause 4.2 is in the form of a demand guarantee, and the amount guaranteed under them when the Taking-Over Certificate is issued is more than half of the Retention Money, then the Retention Money guarantee will not be required. If the amount guaranteed under the Performance Security when the Taking-Over Certificate is issued is less than half of the Retention Money, the Retention Money guarantee will only be required for the difference between half of the Retention Money and the amount guaranteed under the Performance Security.
15.2 Termination for Contractor’s Default
15.2.1 Notice
Following text is added at the end of sub-paragraph (h) of this Sub-Clause:
“For the purposes of this Contract, corrupt and fraudulent practices have been defined in Public Procurement Rules 2026.”
15.2.3 After Termination
The word “and” at the end of sub-paragraph (ii) of paragraph (b) is deleted the following paragraph is added after sub-paragraph (iii):
“(iv) all Employer-Supplied Materials and/or Employer's Equipment madeavailable to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer's Equipment], and”
15.4 Payment after Termination
The following text is added at the end of this Sub-Clause:
“The Employer shall be entitled to sell any of the Contractor’s Equipment, Temporary Works and unused materials and apply the proceeds of sale towards payment of any debt due from the Contractor to the Employer under this Clause including any outstanding payments to the Subcontractors.
16.2 Termination by Contractor
16.2.1 Notice
The sub-paragraph (j) is deleted in its entirety.
At the end of sub-paragraph (i) “; or” is replaced with “.” and at the end of sub-paragraph (h) “;” is replaced with “; or”.
In sub-paragraph (f) “84 days” are replaced with “180 days” and text “for reasons not attributable to the Contractor” is added at the end.
16.3 Contractor’s Obligations After Termination
Sub-paragraph (c) is deleted and replaced with:
"(c) deliver to the Engineer all Employer-Supplied Materials and/orEmployer's Equipment made available to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer’s Equipment]; and
(d) remove all other Goods from the Site, except as necessary for safety,and leave the Site."
17.1 Responsibility for Care of the Works
After the two instances of “Goods” in the last paragraph, the words “Employer-Supplied Materials and/orEmployer's Equipment” are added.
The following Sub-Clause 17.7 is added after Sub-Clause 17.6:
17.7 Use of Employer’s Accommodation/Facilities
The Contractor shall take full responsibility for the care of the items of the Employer’s facilities and/or accommodation, if any, as detailed in the Specification, from the date of use and/or occupation by the Contractor until the date on which such use and/or occupation is re-vested in the Employer.
If any loss or damage happens to any of the above items during a time while the Contractor is responsible for its care, arising from any cause other than a cause for which the Employer is responsible or liable, the Contractor shall promptly rectify the loss or damage at the Contractor’s risk and cost.
18.1 Exceptional Events
The words “or disorder” are replaced with “disorder or sabotage” in sub-paragraph (c) of the Clause.
18.4 Consequences of an Exceptional Event
The following is added at the end of sub-paragraph (b) after deleting the “.”:
“, including the costs of rectifying or replacing the Works and/or Goods damaged or destroyed by Exceptional Events, to the extent they are not indemnified through the insurance policy referred to in Sub-Clause 19.2 [Insurance to be provided by the Contractor].”
18.5 Optional Termination
In sub-paragraph (c), the words “and necessarily” areadded after the words “was reasonably”.
19.1 General Requirements
Following text is added at the end of first paragraph:
“The Contractor shall immediately after the date of the Letter of Acceptance submit the draft of insurance policies for the Employer’s consent.”
Following text is added at the end of third paragraph:
“The Contractor shall, within the respective periods stated in the Contract Data submit to the Engineer and the Employer a) evidence that the insurances described in this Clause have been effected, and b) copies of policies of the insurances described in Sub-Clauses 19.2.1, 19.2.4 and 19.2.5.”
19.2 Insurance to be provided by the Contractor
19.2.5 Injury to employees
The words “sickness, disease” are deleted in the third line of first paragraph.
The following Sub-Clause is added after Sub-Clause 19.2.6:
19.2.7 Insurance Company
“The Contractor shall be obliged to place all insurances described in this Clause with insurers listed in the Contract Data and rated byPACRA/VISofrating as provided in Table below:
Accepted Contract Amount (In Eq. million PKR) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
21.6 Arbitration
The word “international” is deleted in the sixth line of first paragraph. The text of sub-paragraph (a) is substituted with the following:
“the Dispute shall be finally settled under the Rules of Arbitration, specified in the Contract Data;”
The following Clauses are added after Clause 21
22 Custom Duty
[Employer may incorporate provisions where applicable. However, in order to make the bid more balanced, the payment of Customs Duties should be the responsibility of the Employer.]
23 Taxes
The Contractor, Subcontractors and their employees shall be liable to pay income tax, withholding tax, super tax and other taxes on income arising out of the Contract. The rates and prices as stated in the contract shall be deemed to cover all such taxes.
24 Integrity Part
If it is found and established at any stage that the Contractor or any of his Subcontractors, agents or servants have violated or involved in violation of the Integrity Pact signed by the Contractor then the Employer shall be entitled to :
(a) recover from the Contractor an amount equivalent to ten times the sum of any commission, gratification, bribe, finder’s fee or kickback given by the Contractor or any of his Subcontractors, agent or servants;
(b) terminate the Contract; and
(c) recover from the Contractor any loss or damage to the Employer as a result of such termination or of any other corrupt business practices of the Contractor or any of his Subcontractors, agent or servants.
The termination under sub-paragraph(b) of this Sub-Clause shall proceed in the manner prescribed under Sub-Clause 15.1 to 15.4 and the payment under Sub-Clause 15.4 shall be made after having deducted the amounts due to the Employer under sub-paragraph(a) and (c) of this Sub-Clause.
Appendix General Conditions of Dispute Avoidance/Adjudication Agreement
12 Disputes Under DAAB Agreement
In the first paragraph, third, fourth and fifth line, the text “under the Rules of Arbitration of the International Chamber of Commerce 2017……………shall apply” is substituted with “under the Arbitration Act 1940 by sole arbitrator appointed by the Managing Director Public Procurement Regulatory Authority or Chairman Pakistan Engineering Council.”
Date:
No.:
Alternative No.: P202140
To: Quetta Airport (Pakistan Airports Authority (PAA)), Secretary Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid-Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
(a) have withdrawn our Bid during the period of Bid validity specified in the Letter of Bid; or
(b) having been notified of the acceptance of our Bid by the Procuring agency/Employer during the period of Bid validity, (i) fail or refuse to sign the Contract; or (ii) fail or refuse to furnish the Performance Security (or guarantee), if required, in accordance with the ITB.
We understand this Bid Securing Declaration shall expire if we are not the successful Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight days after the expiration of our Bid.
Name of the Bidder*
Name of the person duly authorized to sign the Bid on behalf of the Bidder** _______
Title of the person signing the Bid ______________________
Signature of the person named above ______________________
Date signed ________________________________ day of ___________________, _____
*: In the case of the Bid submitted by joint venture specify the name of the Joint Venture as Bidder
**: Person signing the Bid shall have the power of attorney given by the Bidder attached to the Bid
[Note: In case of a Joint Venture, the Bid-Securing Declaration must be in the name of all members to the Joint Venture that submits the Bid.]
THIS CONTRACT AGREEMENT (hereinafter called the “Agreement”) made on the _________ day of __________ (month) 20_____ between Quetta Airport (Pakistan Airports Authority (PAA)), Secretary Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province). (hereinafter called the “Employer”) of the one part and __________________________________________________ (hereinafter called the “Contractor”) of the other part.
WHEREAS the Employer is desirous that certain Works, viz., Operationalization of Dalbandin Airport (Rehabilitation of Airside Pavements, Security Fence, PTB and Allied Works) (P202140) should be executed by the Contractor and has accepted a Bid by the Contractor for the execution and completion of such Works and the remedying of any defects therein.
NOW this Agreement witnessed as follows:
1. In this Agreement words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract hereinafter referred to.
2. The following documents, in the order of priority, after incorporating addenda, if any, except those parts relating to Instructions to Bidders shall be deemed to form and be read and construed as part of this Agreement:
a) This Contract Agreement;
b) The Letter of Acceptance;
c) The Letter of Bid;
d) The Particular Conditions Part A - Contract Data;
e) The Particular Conditions Part B - SpecialProvisions;
f) The General Conditions;
g) The Specifications Part A - SpecificProvisions;
h) The Specifications Part B- Technical Provisions;
i) The Drawings;
j) The Completed Schedules to Bid including Schedule of Prices;
k) the JV Undertaking (if the Contractor is a JV); and
l) [Employer to insert any other documents forming part of the Contract]
The addenda/corrigenda,if any, (Excluding part relating to Instructions to Bidders alongwith Bidding Data) shall be deemed to have been incorporated at the appropriate places in the “Documents forming the Contract”.
3. In consideration of the payments to be made by the Employer to the Contractor as hereinafter mentioned, the Contractor hereby covenants with the Employer to execute and complete the Works and remedy defects therein in conformity and in all respects with the provisions of the Contract.
4. The Employer hereby covenants to pay the Contractor, in consideration of the execution and completion of the Works as per provisions of the Contract, the Contract Price or such other sum as may become payable under the provisions of the Contract at the times and in the manner prescribed by the Contract.
IN WITNESS WHEREOF the parties hereto have caused this Agreement to be executed on the day, month and year first before written in accordance with their respective laws.
Signature of the Contactor Signature of Employer
(Seal) (Seal)
Signed, Sealed and Delivered in the presence of:
Witness Witness
(Name, Title and Address) (Name, Title and Address)
[All italicised text and any text within square brackets (except sub-clause headings) in this form of agreement is for use in preparing the form and should be deleted from the final product].
Name and details of the Contract Operationalization of Dalbandin Airport (Rehabilitation of Airside Pavements, Security Fence, PTB and Allied Works)
______________________________________________________________________________
This Agreement made the ______day of ______ [month], _____ [year], between
Name and contact details of the Employer Quetta Airport (Pakistan Airports Authority (PAA)), Secretary
Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province).
+92-322-826-8402
rasheedbizenjo35@gmail.com
Name and contact details of the Contractor _____________________________________ (name)
____________________________________ (address)
__________________________________ (telephone)
___________________(email / other contact details);
Name and contact details of the DAAB Member _____________________________________ (name)
____________________________________ (address)
__________________________________ (telephone)
___________________(email / other contact details);
Whereas:
A. the Employer and the Contractor have entered (or intend to enter) into the Contract;
B. under the Contract, the “DAAB” or “Dispute Avoidance/Adjudication Board” means the sole member or three members (as stated in the Contract Data of the Contract) so named in the Contract, or appointed under Sub-Clause 21.1 [Constitution of the DAAB] or Sub-Clause 21.2 [Failure to Appoint DAAB Members] of the Conditions of Contract;
C. the Employer and the Contractor desire jointly to appoint the above-named DAAB Member to act on the DAAB as:
a. the sole member of the DAAB, and where this is the case, all references to the “Other Members” do not apply; or
b. one of three members / chairman [delete the one which is not applicable] of the DAAB and, where this is the case, the other two persons are:
____________________________ (name) _________________________ (name)
___________________________ (address) _______________________ (address)
_____________________________(telephone) ______________________(telephone)
______________(email/ other contact details) _______ (email/other contact details)
the “Other Members”; and
D. the DAAB Member accepts this appointment.
The Employer, Contractor and DAAB Member jointly agree as follows:
1. The conditions of this DAAB Agreement comprise:
(a) Clause 21 [Disputes and Arbitration] of the Conditions of Contract, and any other provisions of the Contract that are applicable to the DAAB’s Activities; and
(b) the “General Conditions of Dispute Avoidance/Adjudication Agreement”, which is appended to the General Conditions of the “Conditions of Contract for Construction” Second Edition 2017 published by FIDIC (“GCs”), as amended and/or added to by the following provisions.
2. [Details of amendments to the GCs, if any. For example:
In the procedural rules annexed to the GCs, Rule _ is deleted and replaced by: “ … “]
3. The DAAB Member shall be paid in accordance with Clause 9 of the GCs. The currency of payment shall be ________.
In respect of Sub-Clauses 9.1 and 9.2 of the GCs, the amounts of the DAAB Member’s monthly fee and daily fee shall be:
monthly fee___________________ per month, and
daily fee of____________________ per day
(or as otherwise set under Sub-Clause 9.3 of the GCs).
4. In consideration of the above fees, and other payments to be made to the DAAB Member in accordance with the GCs, the DAAB Member undertakes to act as DAAB Member in accordance with the terms of this DAAB Agreement.
5. The Employer and the Contractor shall be jointly and severally liable for the DAAB Member’s fees and other payments to be made to the DAAB Member in accordance with the GCs.
6. This DAAB Agreement shall be governed by the law of _____________ (if not stated, the law that governs the Contract under Sub-Clause 1.4 of the Conditions of Contract).
SIGNED by:_______________ SIGNED by:_______________ SIGNED by:_______________
Print name:_________________ Print name:_________________ DAAB Member
Title: _____________________ Title:______________________ Title:______________________
for and on behalf of the
Employer for and on behalf of the
Contractor
in the presence of in the presence of in the presence of
Witness:___________________ Witness:___________________ Witness:___________________
Name:_____________________ Name:_____________________ Name:_____________________
Address:___________________ Address:___________________ Address:___________________
__________________________ __________________________ __________________________
Date:______________________ Date:______________________ Date:______________________
Guarantee No._________________________________________ Date _________________
WHEREAS _____________________________________ (hereinafter called the 'Employer')
has entered into a Contract for __________________________________________________
(Particulars of Contract)
with ____________________________________________ (hereinafter called the "Contractor').
AND WHEREAS, the Employer has agreed to advance to the Contractor, at the Contractor's request, an amount of Pak Rupees ___________________________________ (PKR _________ ) which amount shall be advanced to the Contractor as per provisions of the Contract.
AND WHEREAS, the Employer has asked the Contractor to furnish Guarantee to secure the mobilization advance for the performance of his obligations under the said Contract.
AND WHEREAS, ____________________________________________________________
(hereinafter called the “Guarantor”) at the request of the Contractor and in consideration of theEmployer agreeing to make the above advance to the Contractor, has agreed to furnish the said Guarantee.
NOW, THEREFORE, the Guarantor hereby guarantees that the Contractor shall use the advance for the purpose of above mentioned Contract and if he fails and commits default in fulfilment of any of his obligations for which the advance payment is made, the Guarantor shall be liable to the Employer for payment not exceeding the aforementioned amount.
Notice in writing of any default,on the part of the Contractor, of which the Employer at his discretion of making decision, shall be given by the Employer to the Guarantor, and on such first written demand, payment shall be made by the Guarantor of all sums then due under this Guarantee without any reference to the Contractor and without any objection.
This Guarantee shall remain in force until the advance is fully adjusted against payments from the Interim Payment Certificates of the Contractor or until _________________________whichever is earlier. (Date)
The Guarantor's liability under this Guarantee shall not in any case exceed the sum of
PKR ______________________ (PakRupees ________________________________________________).
This Guarantee shall remain valid up to the aforesaid date and shall be null and void after the aforesaid date or earlier if the advance made to the Contractor is fully adjusted against paymentsfrom Interim Payment Certificates of the Contractor provided that the Guarantor
agrees that the aforesaid period of validity shall be deemed to be extended if on the above mentioned date the advance payment is not fully adjusted.
Guarantor
(Scheduled Bank/ Insurance Company)
Signature ________________________________________________
Name ________________________________________________
Title ________________________________________________
WITNESS:
1. ________________________________________________
________________________________________________
Corporate Secretary (Seal) Corporate Guarantor (Seal)
2. ________________________________________________
________________________________________________
Name, Title & Address
________________________________ [Guarantor letterhead or SWIFT identifier code]
Beneficiary: ___________________ [Insert name and Address of Employer]
Date: ________________[Insert date of issue]
RETENTION MONEY GUARANTEE No.: [Insert guarantee reference number]
Guarantor: [Insert name and address of place of issue, unless indicated in the letterhead]
We have been informed that ________________ [insert name of Contractor, which in the case of a joint venture shall be the name of the joint venture] (hereinafter called "the Contractor") has entered into Contract No. _____________ [insert reference number of the contract] dated ____________ with the Employer, for the execution of _____________________ [insert name of contract and brief description of Works] (hereinafter called "the Contract").
Furthermore, we understand that, according to the conditions of the Contract, the Employer retains moneys up to the limit set forth in the Contract (“the Retention Money”), and that when the Taking-Over Certificate has been issued under the Contract and the first half of the Retention Money has been certified for payment, payment of [insert the second half of the Retention Money orifthe amount guaranteed under the Performance Guarantee when the Taking-Over Certificate is issued is less than half of the Retention Money, the difference between half of the Retention Money and the amount guaranteed under the Performance Security and, if required, the ES Performance Security] is to be made against a Retention Money guarantee.
At the request of the Applicant, we, as Guarantor, hereby irrevocably undertake to pay the Beneficiary any sum or sums not exceeding in total an amount of ___________ [insert amount in figures] () [amount in words] upon receipt by us of the Employer’s complying demand supported by the Beneficiary’s statement, whether in the demand itself or in a separate signed document accompanying or identifying the demand, stating that the Applicant is in breach of its obligation(s) under the Contract, without your needing to prove or show grounds for your demand or the sum specified therein.
A demand under this guarantee may be presented as from the presentation to the Guarantor of a certificate from the Employer’s bank stating that the second half of the Retention Money as referred to above has been credited to the contractor on its account number ___________ at _________________ [insert name and address of Contractor’s bank].
This guarantee shall expire no later than the …. day of ……, 2…, and any demand for payment under it must be received by us at the office indicated above on or before that date.
____________________
[signature(s)]
Note: All italicized text (including footnotes) is for use in preparing this form and shall be deleted from the final product.
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
Name of Employer: ……………… Name of Bidder/Contractor: ……………
Signature: …………………… Signature: …………………………….
[Seal] [Seal]
Guarantee No.___________________
Executed on ____________________
Expiry date _____________________
Name of Guarantor with address: _________________________________________________________________________________________________________________________________
Name of Principal (Contractor) with address:___________________________________________________________________________________________________________________________
Penal Sum of Security (express in words and figures) ____________________________________________________________________________________________________________________
Letter of Acceptance No. _____________________________________Dated __________________
KNOW ALL MEN BY THESE PRESENTS, that in pursuance of the terms of the Bidding Documents and above said Letter of Acceptance (hereinafter called the Documents) and at the request of the said Principal we, the Guarantor above named, are held and firmly bound unto the Quetta Airport (Pakistan Airports Authority (PAA)), Secretary Quetta Airport., Sadar, Quetta (District), Quetta Division (Division), Balochistan (Province). (hereinafter called the Employer) in the penal sum of the amount stated above for the payment of which sum well and truly to be made to the said Employer, we bind ourselves, our heirs, executors, administrators and successors, jointly and severally, firmly by these presents.
THE CONDITION OF THIS OBLIGATION IS SUCH, that whereas the Principal has accepted the Employer's above said Letter of Acceptance for _____________________________________ ________________________________
(Name of Contract) for the Operationalization of Dalbandin Airport (Rehabilitation of Airside Pavements, Security Fence, PTB and Allied Works) (P202140)
______________________________________________ (Name of Project).
NOW THEREFORE, if the Principal (Contractor) shall well and truly perform and fulfill all the undertakings, covenants, terms and conditions of the said Documents during the original terms of the said Documents and any extensions thereof that may be granted by the Employer, with or without notice to the Guarantor, which notice is, hereby, waived and shall also well and truly perform and fulfill all the undertakings, covenants terms and conditions of the Contract and of any and all modifications of said Documents that may hereafter be made, notice of which modifications to the Guarantor being hereby waived, then, this obligation to be void; otherwise to remain in full force and virtue till all requirements of Clause11, Defects After Taking Over, of Conditions of Contract are fulfilled.
Our total liability under this Guarantee is limited to the sum stated above and it is a condition of any liability attaching to us under this Guarantee that the claim for payment in writing shall be received by us within the validity period of this Guarantee, failing which we shall be discharged of our liability, if any, under this Guarantee.
We, _________________________________________________ (the Guarantor), waiving all objections and defense under the Contract, do hereby irrevocably and independently guarantee to pay to the Employer without delay upon the Employer's first written demand without cavil or arguments and without requiring the Employer to prove or to show grounds or reasons for such demand any sum or sums up to the amount stated above, against the Employer's written declaration that the Principal has refused or failed to perform the obligations under the Contract which payment will be effected by the Guarantor to Employer’s designated Bank & Account Number.
PROVIDED ALSO THAT the Employer shall decide, whether the Principal (Contractor) has duly performed his obligations under the Contract or has defaulted in fulfilling said obligations and the Guarantor shall pay without objection any sum or sums up to the amount stated above upon first written demand from the Employer forthwith and without any reference to the Principal or any other person.
IN WITNESS WHEREOF, the above-bounden Guarantor has executed this Instrument under its seal on the date indicated above, the name and corporate seal of the Guarantor being hereto affixed and these presents duly signed by its undersigned representative, pursuant to authority of its governing body.
Guarantor
(Schedule Bank/ Insurance Company)
Signature: _________________________________________________
Name: _________________________________________________
Title: _________________________________________________
Corporate Guarantor (Seal)
WITNESS:
1.
_________________________________________________
_________________________________________________
2.
_________________________________________________
_________________________________________________
Name, Title & Address
Mandatory Requirement. Please attach signed and stamped copy of the document.
Mandatory Requirement: Please attached filled, signed and stamped BoQ