In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Â
Â
PNSC (CSR), Actg. General Manager Finance
FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI
+92-333-326-2196
shoais.pervaiz@pnsc.com.pk
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency:Â PNSC (CSR) The subject of procurement is:Â REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY Expected commencement date: Monday, July 20, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency:Â 2025-26 Name and identification number of the Contract: P36011Â |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Tuesday, June 2, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on PNSC (CSR) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid: No |
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2Â |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
 Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 120 Days |
| 14. |
17.1Â |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Bank Guarantee  |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Monday, June 8, 2026 11:00 AM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Monday Date:Â June 08, 2026 Time : 11:30 AM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 5.00%. The Performance Guarantee shall be acceptable in the form of:Â Pay Order, Bank Guarantee |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Individual / Individual Consultant Sole Proprietorship Partnership Firm Company (Private Limited) Company (Public Limited) Company (Holding Company) Company (Limited by Guarantee) State Owned Enterprise (Private Limited) State Owned Enterprise (Public Limited) | NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) PEC |
| Eligibility Criteria | Document |
|---|---|
| Valid Pakistan Engineering Council (PEC) for the year 2026 in Category C-4 or above | Yes |
| Valid Sales Tax Certificate from Sales Tax Authorities (Sindh Revenue Board SRB). | Yes |
| The bidder/firms must be duly enlisted on the Active Taxpayer List (ATL) maintained by the Federal Board of Revenue, with an active status for Income Tax and an operative status for Sales Tax at the time of bid submission and throughout the procurement process. | Yes |
| The bidder shall furnish an affidavit on a stamp paper of PKR 100/- duly notarized, affirming that the firm has not been blacklisted by any Procuring Agency, Government or Semi-Government Department, Autonomous Body, or International Organization operating in Pakistan. The bidder shall further declare that the firm has no history of litigation and has never engaged in any corrupt, fraudulent, collusive, or unethical practices. The bidder shall also undertake and certify that all information and | Yes |
Least Cost Based Selection (LCBS)
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 70 | |
| a. Work Experience | ||
| i) Experience of Overall works of the firm as prime contractor (10 points for each project of Rs. 50 Million or above satisfactorily completed in last 12 years up to a maximum of 03 such projects). Documentary proof (i.e. work order & completion certificate) to be attached (Quantitative)(Doc Required)  3 projects of Rs. 50 Million or above satisfactorily completed in last 12 years  (30)  2 projects of Rs. 50 Million or above satisfactorily completed in last 12 years  (20)  1 project of Rs. 50 Million or above satisfactorily completed in last 12 years  (10) | 30 | |
| ii) Experience of Similar/ Building of the firm as prime contractor (5 points for each project of Rs. 50 Million or above satisfactorily completed in last 05 years up to a maximum of 03 such projects). Documentary proof (i.e. work order & completion certificate) to be attached. (Quantitative)(Doc Required)  3 projects of Rs. 50 Million or above satisfactorily completed in last 05 years  (15)  2 projects of Rs. 50 Million or above satisfactorily completed in last 05 years  (10)  1 project of Rs. 50 Million or above satisfactorily completed in last 05 years  (5) | 15 | |
| iii) Regional Experience of Similar/ Building works of the firm as prime contractor (5 points for each project of Rs. 50 Million or above satisfactorily completed in last 05 years up to a maximum of 03 such projects). Documentary proof (i.e. work order & completion certificate) to be attached. (Quantitative)(Doc Required)  3 projects of Rs. 50 Million or above satisfactorily completed in last 05 years  (15)  2 projects of Rs. 50 Million or above satisfactorily completed in last 05 years  (10)  1 project of Rs. 50 Million or above satisfactorily completed in last 05 years  (5) | 15 | |
| b. Personal Capability and Equipment | ||
| Project Manager (Must be a University Engineering Degree Holder in Civil) B.E./B.Sc. Civil or Master’s Degree in Civil/ Construction Engineering (Quantitative)(Doc Required) | 1 | |
| Project Manager Total Work Experience (Years) (Quantitative)(Doc Required) Â Total Work Experience (More Than 20 Years) Â (2) Â Total Work Experience (More Than 10 Years) Â (1) | 2 | |
| Project Manager Specific Work Experience (More than 10 Years) (Quantitative)(Doc Required) | 1 | |
| Site Engineer (Must be a University Engineering Degree Holder in Civil) B.E. Civil (Quantitative)(Doc Required) | 1 | |
| Site Engineer with Minimum Total experience of 4 years and Specific experience of 4 years (Quantitative)(Doc Required) | 1 | |
| Lab Technician (At least holds Diploma of Associate Engineer in Civil) D.A.E. Civil with Total Work Experience of more than 4 Years and specific experience of 3 years (Quantitative)(Doc Required) | 1 | |
| Quantity Surveyor (At least holds Diploma of Associate Engineer in Civil) with Total Work Experience of more than 4 Years and specific experience of 3 years (Quantitative)(Doc Required) | 1 | |
| Surveyor (At least holds Diploma of Associate Engineer in Civil) with Total Work Experience of more than 4 Years and specific experience of 3 years (Quantitative)(Doc Required) | 1 | |
| Site Supervisor (At least holds Diploma of Associate Engineer in Civil) with Total Work Experience of more than 4 Years and specific experience of 3 years (Quantitative)(Doc Required) | 1 | |
| List of machinery and equipment intended to be used on the projects with proof of ownership. (Quantitative)(Doc Required) | 5 | |
| c. Financial Position and Litigation History | ||
| i. Audited Account Report for last 03 years (Quantitative)(Doc Required) | 5 | |
| ii. Average Annual turnover of last 03 Years ( to be ascertained from Audited Reports) (Quantitative)(Doc Required) Â More than Rs 400 M Â (15) Â Rs 260.1 M to Rs. 300 M Â (12) Â Rs 120.1 M to Rs. 260 M Â (9) Â Rs 80.1 M to Rs 120 M Â (6) Â Rs 40 M to Rs. 80 M Â (3) | 15 | |
| iii. Banker’s certificate for financially soundness, issued in last 06 months, that the bidder has sufficient amount in particular. (Quantitative)(Doc Required) | 5 | |
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY | Address: PAKISTAN MARINE ACADEMY Schedule: 160 Days Quantity: 1 | 1 | 2326397.4 |
| Item | UNSPSC | Delivery Schedule | Quantity | Bid Security | Related to Job/Lot |
|---|---|---|---|---|---|
| REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY | Commercial and office building renovation and repair service |
Address: PAKISTAN MARINE ACADEMY
Schedule: 160 Days
Quantity: 1
|
1 | 3 | REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY (Job) |
No
Jobs Without Lots :
Job: REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY
Specifications / Requirements:
| Sr. No | Ref. No. | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|---|
| 1 | REWA/1 | Dismantling R.C.C. including separating reinforcement from concrete including stacking at site and disposing of unserviceable material complete and as per instructions of Engineer in charge. | %Cft | 9809 | 161.5 | 1,584,154 |
| 2 | REWA/2 | Dismantling Block masonry including disposing of surplus material and Providing & laying pre-cast solid blocks masonary using 6"x8"x12" size pre-cast blocks of min 1000 psi compressive strength set in cement mortar 1:5 in any floor superstructure including scaffolding, raking out joints & curing and plastering with 1/2" (13 mm) thick cement plaster 1:6 complete. complete and as per instructions of engineer in charge | %Cft | 388 | 872.93 | 338,697 |
| 3 | REWA/3 | Clearing and grubbing the site by cutting, uprooting and removing all rubbish and shrubs including disposal to (outside limits) designated places. | %Sft | 2291 | 1.8 | 4,124 |
| 4 | REWA/4 | Providing and laying Ready mix Reinforced concrete 4000 Psi cylindrical strength using stationary or any other pumps, as in roof, slabs, walls, landings, plinth beams,rafts and bands etc as specified requiring steel shuttering etc complete & as per instructions of engineer in charge. Reinforcement to be measured and paid separately. | %Cft | 9291 | 891.4 | 8,281,997 |
| 5 | REWA/5 | Providing and laying deformed (minimum yield point 60,000 psi) reinforcement bars with & including the cost of straightening, cutting, bending, binding, placing in position in all kinds of RCC work in foundation, basement, plinth and any floor of building and as per direction of engineer in charge. | %Kg | 16858 | 381.62 | 6,433,350 |
| 6 | REWA/6 | Providing loose concrete near the Corroded Exposed Rebars and adjacent to the corroded area, wire brushing of rebars,applying zinc Rich on Rebars,nailing the treated surface by concrete nails if 8 BWG, applying SBR all around the surface, placing 20 BWG Expanded Metal and laying with installed nails and plastering with 1:3 cement sand Mortar mixed with plasticizer and finishing the surface to fine and level the surrounding surface. | %Sft | 948 | 2911.66 | 2,760,254 |
| 7 | REWA/7 | Rehablitation of Columns By cutting the damaged surface and brushing of existing steel bars to remove the rust, and coating the bars with zinc rich primer to protect from rust, add new bars where required by drilling holes and filling the holes with chemical grout and concreting the column with 5000PSI Concrete as per drawings, site requirement and direction of engineer incharge. | %Sft | 722 | 953.67 | 688,550 |
| 8 | REWA/8 | Rehabilitation of Plinth Beams by Cutting the damaged surface and brushing of existing steel bars to remove the rust, and coating the bars with zinch rich primer, excavate the area to add lean 1:2:4 below plinth beam, add new bars and concreting the beam with 5000 PSI concrete as per drawings, site requirement and direction of engineer incharge. | %Rft | 42 | 3547.96 | 149,014 |
| 9 | CPB/1 | 1/2" (13 mm) thick cement plaster 1:4 on walls and columns etc. making edges, comers, and curing etc., complete. (Internal Plaster) | %Sft | 927 | 79.1 | 73,326 |
| 10 | CPB/2 | 3/8" (10 mm) thick cement plaster 1:4 including making edges, corners, and curing etc. (Ceiling Plaster) | %Sft | 11973 | 59.63 | 713,950 |
| 11 | CPB/3 | 3/4" (19 mm) thick cement plaster 1:4 including making edges, corners, and curing etc. (External Plaster) | %Sft | 4348 | 68.78 | 299,055 |
| 12 | PC/1 | Removal of old Paint and Painting three coats with weather shield paint (Each coat will be applied after 5 Days) | %Sft | 5296 | 52.24 | 276,663 |
| 13 | PC/2 | Removal of old Paint and Distempering three coats with poly vinyl distemper (Each coat will be applied after 5 Days) | %Sft | 11973 | 43.02 | 515,078 |
| 14 | PC/3 | Removal of old Paint and Preparing the surface and painting three coats with matt finish (Each coat will be applied after 5 Days) | %Sft | 1843 | 56.76 | 104,609 |
| 15 | PC/4 | Providing and fixing angle section of L 6"x6"x1/4" for supporting of Existing Beam and making its connections with Rawal Bolts and using Welding work to attach Angle iron with another Angle iron | %Each | 51 | 1624.45 | 82,847 |
| 16 | FD/1 | Providing & laying floor of mosaic marble chips tile 1" (25mm) thick of approved quality and shade laid in white cement and pigment over 3/4" (20mm) thick bedding in cement sand mortar 1:2 including finshing and polishing complete as per Approval of Client | %Sft | 11510 | 222.88 | 2,565,349 |
| 17 | FD/2 | Laying floor of approved with glazed tiles 1/4" thick dado of approved color & size jointing in white cement and laid over 1:2 cement sand mortor 3/4" thick including grouting with matching color and finishing | %Sft | 675 | 389.36 | 262,818 |
| 18 | RTE/1 | Providing water proofing roof treatment by Dismentaling old Screeding and providing hot bitumen layer with Insulation Board and sand as slope after screeding provided for water drainage. | %Sft | 11963 | 104.96 | 1,255,636 |
| 19 | RTE/2 | Providing and laying 3" thick topping of cement concrete (1:2:4 ) including Surface finishing and dividiing into panels: | %Sft | 11963 | 145 | 1,734,635 |
| 20 | DWF/1 | Providing and fixing Alminium windows & Ventilator box section including the cost of glass pan, aluminium fittings, with all accessories cutting hole etc. and making good damages to walls etc. complete as required in any floor as per direction of engineer-in-charge | %Sft | 558 | 1358.5 | 758,043 |
| 21 | DWF/2 | First Class deodar wood wrought joinery in doors and windows etc. panelled or panelled or glazed or fully glazed fixed in position including chowkhat, holdfast, hinges, tower bolt rubber stop cleats/G I clamp,handles and chord with hooks etc. complete (excluding sliding bolts or lock). | %Sft | 460 | 3000 | 1,380,000 |
| 22 | DWF/3 | Supplying & fixing in position iron/steel grill of 3/4" x 1/4" size flat iron of approved design including painting 3 coats etc. complete (weight not to be less than 3.7 Lbs./Sq . Foot of finished grill) | %Sft | 558 | 1125 | 627,750 |
| 23 | PPG/1 | Excavation for Plinth Protection about 1.5ft wide & 1.5ft Deep and Providing CC 1:4:8 Below Foundation with 6" Thick Block Masonry and laying 50mm Pavers, 2" Thick Sand Cushion,4" Thk Gravel Layer and 4" Thk 1:3:6 as Per Direction of Engineer-in-Charge. | %Rft | 482 | 5617.82 | 2,707,789 |
| 24 | PH/a/1 | 25mm 1" --PPRC pipe PN-20 | %Rft | 66 | 899.41 | 59,361 |
| 25 | PH/b/1 | 50mm 2" --PPRC pipe PN-20 | %Rft | 20 | 3753.42 | 75,068 |
| 26 | PH/c/1 | 1 inches (25mm) dia Ball Valve | %Each | 2 | 212.26 | 425 |
| 27 | PH/d/1 | 1-1/2 inches (40mm) dia Ball Valve | %Each | 3 | 399.26 | 1,198 |
| 28 | PH/e/1 | 2 inches (50mm) dia Ball Valve | %Each | 2 | 652.26 | 1,305 |
| 29 | PH/g/1 | 4 inches (100 mm) dia pipe. --(U.P.V.C) "E" class | %Rft | 40 | 5354.32 | 214,173 |
| 30 | PH/2 | Supplying & fixing Fiber glass tank of approved quality and design and wall thickness as specified including cost of nuts, bolts and fixing in plat form of cement concrete 1:3:6 and making connection for inlet, outlet and over flow pipes etc. complete 350 gallons tank with wall thickness 4.0mm | %Each | 2 | 50000 | 100,000 |
| 31 | PH/3 | Providing and fixing squatting type white glazed earthen ware W.C pan with front flush inlet & complete with including the cost of flushing cistern with internal fitting and flush pipe with bend and requiste number of holes in walls plinth & floor for pipe connection & making good in cement concrete 1:2:4 Far.(23 inch | %Each | 2 | 10440.5 | 20,881 |
| 32 | PH/4 | Providing and fixing European type white glazed earthen ware wash down W.C. pan complete with & including the cost of white / black plastic seat ( Best quality ) and lid with C.P. brass hinges best quality and buffers 3 gallons white glazed earthen ware low level flushing cistem with siphon fitting 1½ " dia white porcelain enameled flush bend dia and making requisite number of holes in walls , plinth & floor for pipe connection & making good in cement concrete 1:2:4 | %Each | 2 | 24100 | 48,200 |
| 33 | PH/5 | Providing and fixing 24x18" lavatory basin in white glazed carthen ware complete with &e including the cost of W.I. or C.I. cantilever bracket 6 inches built into wall, painted white in two coats after a primary coat of red lead paint, a pair of ½" dia chrome plated pillar taps, 1-1/2" rubber plug & chrome plated brass chain 1-1/4" dia malleable iron or C.P. brass traps malleable iron or brass unions and making requisite number of holes in walls, plinth & floor for pipe connection & making good in cement concrete 1:2:4 | %Each | 2 | 9495.14 | 18,990 |
| 34 | PH/6 | Supplying & Fixing wash basin mixture of superior quality with C.P head 1/2" dia with swan type piller cock of Superior quality single c.p. head 1/2" dia. and Providing & fixing in position nyloon connection complete with 1/2" dia brass stop cock with pair of brass nuts and linig joints to nyloon connection . | %Each | 2 | 3773.25 | 7,547 |
| 35 | PH/7 | Upvc rain water down pipe 4" | %Rft | 75 | 399.12 | 29,934 |
| 36 | MI/1 | Installation of ON Grid Solar System 50 KW (Grade- I) | %Nos | 1 | 4836428 | 4,836,428 |
| 37 | MI/2 | Providing & Fixing appropriate numbers of Air Conditioners of 4 Ton | %Nos | 8 | 800000 | 6,400,000 |
| 38 | MI/3 | Providing "Expansion Joint" in concrete work of 9" wide corugated PVC waterstop (with bulb) i.c soldering cost of material and labour etc complete. | %Rft | 68 | 1800 | 122,400 |
| 39 | SJ/1 | Rehablitation of External Sewerage by Repair Or Dismantling R.C.C / pipe & providing and laying New Manhole or Gully Trap where required. | %Rft | 532 | 1000 | 532,000 |
| 40 | EK/a/1 | Providing & laying 20mm dia PVC Conduit recessed / surface (For light & Fan point wiring) | %Rft | 1400 | 40 | 56,000 |
| 41 | EK/a/2 | Providing & laying 25mm dia PVC Conduit recessed / surface (For power plug & circuit wiring) | %Rft | 2800 | 50 | 140,000 |
| 42 | GCK/b/1 | Providing & fixing 12mm dia GI Conduit (For light & Fan extension rod) | %Rft | 350 | 360 | 126,000 |
| 43 | WK/c/1 | Providing & laying 1.5sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For light & Fan point wiring) | %Rft | 17500 | 31 | 542,500 |
| 44 | WK/c/2 | Providing & laying 2.5sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For power plug, circuit and highbay light wiring) | %Rft | 5000 | 64 | 320,000 |
| 45 | WK/c/3 | Providing & laying 4sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For industrial socket wiring) | %Rft | 2200 | 84 | 184,800 |
| 46 | WK/c/4 | Providing & laying 6sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For SPlit AC wiring) | %Rft | 150 | 121 | 18,150 |
| 47 | WK/c/5 | Providing & laying 25sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For DB wiring) | %Rft | 700 | 465 | 325,500 |
| 48 | FFK/d/1 | Providing & fixing PVC box recessed / surface size 3"x3" (For gang switch and socket) | %Nos | 60 | 250 | 15,000 |
| 49 | FFK/d/2 | Providing & fixing PVC box recessed / surface size 6"x3" (For gang switch and socket) | %Nos | 12 | 360 | 4,320 |
| 50 | FFK/d/3 | Providing & fixing PVC box recessed / surface size 8"x6" (For gang switch and socket) | %Nos | 15 | 550 | 8,250 |
| 51 | FFK/d/4 | Providing & fixing 4 gang switch on given junction box good quality | %Nos | 8 | 1250 | 10,000 |
| 52 | FFK/d/5 | Providing & fixing 6 gang switch on given junction box good quality | %Nos | 12 | 1500 | 18,000 |
| 53 | FFK/d/6 | Providing & fixing 10A three pin switch and socket on given junction box good quality | %Nos | 22 | 1400 | 30,800 |
| 54 | FFK/d/7 | Providing & fixing 15A three pin switch and socket on given junction box good quality | %Nos | 16 | 1850 | 29,600 |
| 55 | FFK/d/8 | Providing & fixing 20A industrial socket on given junction box good quality | %Nos | 15 | 2600 | 39,000 |
| 56 | FFK/d/9 | Providing & fixing fan clamp box good quality | %Nos | 64 | 700 | 44,800 |
| 57 | FFK/d/10 | Providing & fixing ceiling fan 56" sweep good quality | %Nos | 64 | 8500 | 544,000 |
| 58 | FFK/d/11 | Providing & fixing Industrial Exhaust Fan 36" dia | %Nos | 1 | 90000 | 90,000 |
| 59 | FFK/d/12 | Providing & fixing fan dimmer good quality | %Nos | 64 | 250 | 16,000 |
| 60 | FFK/d/13 | Providing and fixing 18" sweep metalic body exhaust fan complete with blades, motor, shutter etc including making hole in the wall & connection with 14.0076 flexible wire complete as required. | %Nos | 9 | 9000 | 81,000 |
| 61 | FFK/d/14 | Providing & fixing PVC batten holder good quality | %Nos | 107 | 180 | 19,260 |
| 62 | FFK/d/15 | Providing & fixing PVC ceiling rose good quality | %Nos | 9 | 120 | 1,080 |
| 63 | FFK/d/16 | Providing & fixing LED bulb 30w good quality | %Nos | 107 | 600 | 64,200 |
| 64 | FFK/d/17 | Providing & fixing LED down light 9w good quality | %Nos | 40 | 750 | 30,000 |
| 65 | FFK/d/18 | Providing & fixing LED High bay light 60-100w good quality | %Nos | 18 | 12500 | 225,000 |
| 66 | CWK/e/1 | providing and Installation of CCTV System with Complete Acessories | %Rft | 11500 | 200 | 2,300,000 |
| 67 | DBK/f/1 | Providing & Fixing, testing,commissioning cubical type metal sheet distribution board flush / surface type with locking arrangement duly powder quoted paint including all fastening material including wiring with suitable gauge PVC wire complete in all respect. | %Sft | 6 | 4300 | 25,800 |
| 68 | CBK/g/1 | Providing & fixing 10A to 32A SP MCB circuit breaker in given DB Terasaki or Equalent | %Nos | 90 | 1500 | 135,000 |
| 69 | CBK/g/2 | Providing & fixing 20A to 32A DP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 8 | 2200 | 17,600 |
| 70 | CBK/g/3 | Providing & fixing 100A TP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 4 | 11500 | 46,000 |
| 71 | CBK/g/4 | Providing & fixing 200A TP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 1 | 18000 | 18,000 |
| 72 | CBK/g/5 | Providing & fixing pilot lamp in given DB good quality | %Nos | 9 | 600 | 5,400 |
| 73 | CBK/g/6 | Providing & fixing Ampere meter in given DB good quality | %Nos | 2 | 3500 | 7,000 |
| 74 | CBK/g/7 | Providing & fixing Volt meter in given DB good quality | %Nos | 2 | 3500 | 7,000 |
| 75 | ESK/h/1 | Providing and fixing Earthing set with 2'x2'x1/8" copper plate buried in the ground at a depth of 12 feet or less if water comes out from the ground level (salt & charcoal, or earthing chemical powder) etc. making the pit 12 feet deep by excavation of all type of soil (except soft or hard rock) including fixing of 2x8 SWG copper wire in 1/2" dia GI conduit complete in all respect as required. | %Job | 2 | 70000 | 140,000 |
| 76 | ESK/h/2 | Providing & fixing earth connecting strip size 150mmx20mmx6mm as required. | %Each | 4 | 1500 | 6,000 |
| 77 | CWK/i/1 | P/Laying (Main or Sub Main) Pvc insulated / Pvc sheathed with size 4 core 95sq mm ug cable copper conductor (From Supply Point to M.DB) | %Rft | 100 | 5200 | 520,000 |
| 78 | FL/1 | Examination Hall Seats Good Quality | %Nos | 220 | 6000 | 1,320,000 |
| 79 | RWA/1 | Dismantling Block masonry including disposing of surplus material and Providing & laying pre-cast solid blocks masonary using 6"x8"x12" size pre-cast blocks of min 1000 psi compressive strength set in cement mortar 1:5 in any floor superstructure including scaffolding, raking out joints & curing and plastering with 1/2" (13 mm) thick cement plaster 1:6 complete. complete and as per instructions of engineer in charge | %Cft | 1460 | 872.93 | 1,274,478 |
| 80 | RWA/2 | Clearing and grubbing the site by cutting, uprooting and removing all rubbish and shrubs including disposal to (outside limits) designated places. | %Sft | 9430 | 1.8 | 16,974 |
| 81 | RWA/3 | Providing loose concrete near the Corroded Exposed Rebars and adjacent to the corroded area, wire brushing of rebars,applying zinc Rich on Rebars,nailing the treated surface by concrete nails if 8 BWG, applying SBR all around the surface, placing 20 BWG Expanded Metal and laying with installed nails and plastering with 1:3 cement sand Mortar mixed with plasticizer and finishing the surface to fine and level the surrounding surface. | %Sft | 953 | 2911.66 | 2,774,812 |
| 82 | RWA/4 | Rehablitation of Columns By cutting the damaged surface and brushing of existing steel bars to remove the rust, and coating the bars with zinc rich primer to protect from rust, add new bars where required by drilling holes and filling the holes with chemical grout and concreting the column with 5000PSI Concrete as per drawings, site requirement and direction of engineer incharge. | %Sft | 70 | 953.67 | 66,757 |
| 83 | CPB/1 | 3/4" (19 mm) thick cement plaster 1:4 including making edges, corners, and curing etc. (External Plaster) | %Sft | 1200 | 73 | 87,600 |
| 84 | PC/1 | Removal of old Paint and Painting three coats with weather shield paint (Each coat will be applied after 5 Days) | %Sft | 20 | 52.24 | 1,045 |
| 85 | PC/2 | Removal of old Paint and Distempering three coats with poly vinyl distemper (Each coat will be applied after 5 Days) | %Sft | 98 | 43.02 | 4,216 |
| 86 | PC/3 | Removal of old Paint and Preparing the surface and painting three coats with matt finish (Each coat will be applied after 5 Days) | %Sft | 248 | 56.76 | 14,076 |
| 87 | FD/1 | Providing & laying floor of mosaic marble chips tile 1" (25mm) thick of approved quality and shade laid in white cement and pigment over 3/4" (20mm) thick bedding in cement sand mortar 1:2 including finshing and polishing complete as per Approval of Client | %Sft | 4451 | 222.88 | 992,039 |
| 88 | FD/2 | Laying Verona marble flooring Size 24"x12"x1"/12"x12"x1" fine dressed on the surface without winding set in lime mortar 1:2 including rubbing and polishing of the joints b) 1" thick marble | %Sft | 2806 | 381.88 | 1,071,555 |
| 89 | FD/3 | Laying floor of approved with glazed tiles 1/4" thick dado of approved color & size jointing in white cement and laid over 1:2 cement sand mortor 3/4" thick including grouting with matching color and finishing | %Sft | 1302 | 389.36 | 506,947 |
| 90 | FD/4 | P/F Granite Strips (5''x1''x1'') thick fixed over stair steps of required width set in cement sand mortar 1:2 in gray cement 1''thick in/c washing and filling etc complete. | %Sft | 612 | 1500 | 918,000 |
| 91 | FD/5 | Providing & Laying Full Body Porcelain Tile in Flooring or Facing of Approved Design Set in Gry Cement Motor 1:2 or of 3/4" Thickinss I/C Washing & Joints With White Cement Slurry Using Colour Pigment for matching complete as per Spacification 16"x16"x5/16" thick flooring | %Sft | 6697 | 389.36 | 2,607,544 |
| 92 | FD/6 | Providing and laying, CC Paving stone, 50 mm thick in natural colour, as in floors, ramps etc, any Reference and any shape, are fixed using 1:4 motar 3/4" thick and slurry of cement as the practice adopted in tiles ,granite or marble as per drawing and instruction engineer in charge. | %Sft | 2670 | 230 | 614,100 |
| 93 | FD/7 | Stone cladding of required size on wall facing of approved design shape and pattern set in cement sand mortar ratio 1:2 in gray cement 3/4'' thick in/c washing of joints with net white cement salary and pigment in desire shape in/c cutting and dressing the stone tile to proper profile in/c labour etc complete as per specification as directed by the Engineer / Incharge. | %Sft | 1920 | 541.93 | 1,040,506 |
| 94 | RTE/1 | Providing water proofing roof treatment by Dismentaling old Screeding and providing hot bitumen layer with Insulation Board and sand as slope after screeding provided for water drainage. | %Sft | 45711 | 104.96 | 4,797,827 |
| 95 | RTE/2 | Providing and laying 3" thick topping of cement concrete (1:2:4 ) including Surface finishing and dividiing into panels: | %Sft | 45711 | 145 | 6,628,095 |
| 96 | DWF/1 | Providing and fixing fully glazed aluminium Slinding windows & Ventilator box section including the cost of glass pan, aluminium fittings, with all accessories cutting hole etc. and making good damages to walls etc. complete as required in any floor as per direction of engineer-in-charge | %Sft | 20 | 1358.5 | 27,170 |
| 97 | DWF/2 | First Class deodar wood wrought joinery in doors and windows etc. panelled or panelled or glazed or fully glazed fixed in position including chowkhat, holdfast, hinges, tower bolt rubber stop cleats/G I clamp,handles and chord with hooks etc. complete (excluding sliding bolts or lock). | %Sft | 124 | 3000 | 372,000 |
| 98 | DWF/3 | Supplying & fixing in position iron/steel grill of 3/4" x 1/4" size flat iron of approved design including painting 3 coats etc. complete (weight not to be less than 3.7 Lbs./Sq . Foot of finished grill) | %Sft | 24 | 1125 | 27,000 |
| 99 | PPG/1 | Excavation for Plinth Protection about 1.5ft wide & 1.5ft Deep and Providing CC 1:4:8 Below Foundation with 6" Thick Block Masonry and laying 50mm Pavers, 2" Thick Sand Cushion,4" Thk Gravel Layer and 4" Thk 1:3:6 as Per Direction of Engineer-in-Charge. | %Rft | 1958 | 5617.82 | 10,999,692 |
| 100 | PH/1/a | 25mm 1" --PPRC pipe PN-20 | %Rft | 110 | 899.4 | 98,934 |
| 101 | PH/1/b | 50mm 2" --PPRC pipe PN-20 | %Rft | 70 | 3753.42 | 262,739 |
| 102 | PH/1/c | 1 inches (25mm) dia Ball Valve | %Each | 9 | 212.256 | 1,910 |
| 103 | PH/1/d | 1-1/2 inches (40mm) dia Ball Valve | %Each | 8 | 399.26 | 3,194 |
| 104 | PH/1/e | 2 inches (50mm) dia Ball Valve | %Each | 5 | 652.26 | 3,261 |
| 105 | PH/1/g | 4 inches (100 mm) dia pipe. --(U.P.V.C) "E" class | %Rft | 60 | 5354.32 | 321,259 |
| 106 | PH/2 | Supplying & fixing Fiber glass tank of approved quality and design and wall thickness as specified including cost of nuts, bolts and fixing in plat form of cement concrete 1:3:6 and making connection for inlet, outlet and over flow pipes etc. complete 350 gallons tank with wall thickness 4.0mm | %Each | 3 | 50000 | 150,000 |
| 107 | PH/3 | Providing and fixing squatting type white glazed earthen ware W.C pan with front flush inlet & complete with including the cost of flushing cistern with internal fitting and flush pipe with bend and requiste number of holes in walls plinth & floor for pipe connection & making good in cement concrete 1:2:4 Far.(23 inch | %Each | 9 | 10440.5 | 93,965 |
| 108 | PH/4 | Providing and fixing 24x18" lavatory basin in white glazed carthen ware complete with &e including the cost of W.I. or C.I. cantilever bracket 6 inches built into wall, painted white in two coats after a primary coat of red lead paint, a pair of ½" dia chrome plated pillar taps, 1-1/2" rubber plug & chrome plated brass chain 1-1/4" dia malleable iron or C.P. brass traps malleable iron or brass unions and making requisite number of holes in walls, plinth & floor for pipe connection & making good in cement concrete 1:2:4 | %Each | 9 | 9495.14 | 85,456 |
| 109 | PH/5 | Supplying & Fixing wash basin mixture of superior quality with C.P head 1/2" dia with swan type piller cock of Superior quality single c.p. head 1/2" dia. and Providing & fixing in position nyloon connection complete with 1/2" dia brass stop cock with pair of brass nuts and linig joints to nyloon connection . | %Each | 9 | 3773.25 | 33,959 |
| 110 | PH/6 | Providing and fixing flat black lipped front urinal basin ( of not less than 17 " in height ) of white glazed earthen ware complete with & including the cost of ½ " dia gun metal gate valve with standard flush pipe , waste pipe ( enameled iron ) complete with fitting and making requisite number of holes in walls , plinth & floor for pipe connection & making good in cement concrete 1:2:4 . ( Standard pattern ) | %Each | 5 | 4464.14 | 22,321 |
| 111 | PH/7 | Upvc rain water down pipe 4" | %Rft | 320 | 399.12 | 127,718 |
| 112 | MI/1 | 2” Thick Asphalt Concrete Wearing Course Mix Laying mechanically to proper Asphalt Concrete incharge rolling and finishing to design Proper grade line level and comber etc | %Sft | 161900 | 70 | 11,333,000 |
| 113 | MI/2 | Providing & Fixing appropriate numbers of Air Conditioners of 4 Ton | %Nos | 2 | 800000 | 1,600,000 |
| 114 | MI/3 | Making and fixing fiber glass sun shade standard size 3mm sheet (02 layer) molded in panel in/c M.S Pipe 6'' dia 20' height at 20' center fixing C.C foundation with M.S Square pipe 1-1/2'' x 1-1/2'' double kanchi around from with internal M.S Square pipe 2x2 center to center in/c welding assembling etc complete in all respect | %Each | 2400 | 1200 | 2,880,000 |
| 115 | MI/4 | Deodar wood counter including shutters and shelves complete with iron fitting. | %Sft | 692 | 5000 | 3,460,000 |
| 116 | MI/5 | Providing "Expansiomn Joint" in concrete work of 9" wide corugated PVC waterstop (with bulb) i.c soldering cost of material and labour etc complete. | %Rft | 805 | 1000 | 805,000 |
| 117 | SJ/1 | Rehablitation of External Sewerage by Repair Or Dismantling R.C.C / pipe & providing and laying New Manhole or Gully Trap where required. | %Rft | 1794 | 1000 | 1,794,000 |
| 118 | SJ/2 | Supplying and fixing Centrifugal Pumping set complete with AC, electric motor driven, 400 volts, 3 phase, 50 cycles, 1 hp, mounted on a common channel base, total head 25/30 M | %Each | 1 | 112033 | 112,033 |
| 119 | EK/a/1 | Providing & laying 20mm dia PVC Conduit recessed / surface (For light & Fan point wiring) | %Rft | 40 | 40 | 1,600 |
| 120 | EK/a/2 | Providing & laying 25mm dia PVC Conduit recessed / surface (For power plug & circuit wiring) | %Rft | 15 | 50 | 750 |
| 121 | EK/c/3 | Providing & laying 1.5sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For light & Fan point wiring) | %Rft | 100 | 31 | 3,100 |
| 122 | EK/c/4 | Providing & laying 2.5sq mm PVC wire single core stranded copper conductor in given PVC Conduit recessed / surface (For power plug, circuit and highbay light wiring) | %Rft | 40 | 64 | 2,560 |
| 123 | EK/d/1 | Providing & fixing PVC box recessed / surface size 3"x3" (For gang switch and socket) | %Nos | 2 | 250 | 500 |
| 124 | EK/d/2 | Providing & fixing 4 gang switch on given junction box good quality | %Nos | 1 | 1250 | 1,250 |
| 125 | EK/d/3 | Providing & fixing 10A three pin switch and socket on given junction box good quality | %Nos | 1 | 1400 | 1,400 |
| 126 | EK/d/4 | Providing & fixing fan clamp box good quality | %Nos | 1 | 700 | 700 |
| 127 | EK/d/5 | Providing & fixing ceiling fan 56" sweep good quality | %Nos | 1 | 8500 | 8,500 |
| 128 | EK/d/6 | Providing & fixing fan dimmer good quality | %Nos | 1 | 250 | 250 |
| 129 | EK/d/7 | Providing & fixing PVC batten holder good quality | %Nos | 4 | 180 | 720 |
| 130 | EK/d/8 | Providing & fixing LED bulb 30w good quality | %Nos | 29 | 600 | 17,400 |
| 131 | EK/e/1 | Providing & Fixing, testing,commissioning cubical type metal sheet distribution board flush / surface type with locking arrangement duly powder quoted paint including all fastening material including wiring with suitable gauge PVC wire complete in all respect. | %Sft | 4 | 4300 | 17,200 |
| 132 | EK/g/1 | Providing & fixing 10A to 32A SP MCB circuit breaker in given DB Terasaki or Equalent | %Nos | 38 | 1500 | 57,000 |
| 133 | EK/g/2 | Providing & fixing 20A to 32A DP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 2 | 2200 | 4,400 |
| 134 | EK/g/3 | Providing & fixing 100A TP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 1 | 11500 | 11,500 |
| 135 | EK/g/4 | Providing & fixing 200A TP MCCB circuit breaker in given DB Terasaki or Equalent | %Nos | 1 | 18000 | 18,000 |
| 136 | EK/g/5 | Providing & fixing pilot lamp in given DB good quality | %Nos | 3 | 600 | 1,800 |
| 137 | EK/g/6 | Providing & fixing Ampere meter in given DB good quality | %Nos | 1 | 3500 | 3,500 |
| 138 | EK/g/7 | Providing & fixing Volt meter in given DB good quality | %Nos | 1 | 3500 | 3,500 |
| 139 | FABL/1 | Chart Table | %Nos | 80 | 8250 | 660,000 |
| 140 | FABL/2 | Table | %Nos | 2 | 13200 | 26,400 |
| 141 | FMCM/1 | Clinical Couch | %Nos | 6 | 30800 | 184,800 |
| 142 | FMCM/2 | Examination Trolley | %Nos | 6 | 24750 | 148,500 |
| 143 | FMCM/3 | Bed | %Nos | 15 | 33000 | 495,000 |
| 144 | FMCM/4 | Sofa Set | %Nos | 25 | 23100 | 577,500 |
| 145 | FMCM/5 | Chairs | %Nos | 25 | 20350 | 508,750 |
| 146 | FMCM/6 | Staff Table | %Nos | 5 | 50160 | 250,800 |
| 147 | FMCM/7 | Office Table | %Nos | 4 | 61380 | 245,520 |
| 148 | FMCM/8 | Bed, Patient, Electric | %Nos | 2 | 302500 | 605,000 |
| 149 | FMCM/9 | Cabinet (Fixed/ Display Cabinet) | %Nos | 4 | 75625 | 302,500 |
| 150 | FMCM/10 | Wheel Chair | %Nos | 4 | 22000 | 88,000 |
| 151 | FMCM/11 | Workstation | %Nos | 2 | 38500 | 77,000 |
| 152 | FMCM/12 | Waiting Chairs | %Nos | 14 | 13200 | 184,800 |
| 153 | FMCM/13 | Ward Screen | %Nos | 15 | 12122 | 181,830 |
| GRAND TOTAL: | Rs 116,319,870.00 |
Repair \ renovation and refurbishment of admin block, medical center, parade ground, sports complex, swimming pool & examination hall at Pakistan marine academy
Table of Contents
CIVIL WORKS
Â
1.            Section-1              General                                                                                                                                        Â
2.            Section-2              Site Clearing, Grubbing and Setting out of Works                                                             Â
3.            Section-3              Excavation, Filling, Backfill and Disposal                                                                           Â
4.            Section-4              Termite Control                                                                                                                         Â
5.            Section-5              Water                                                                                                                                           Â
6.            Section-6              Concrete                                                                                                                                      Â
7.            Section-7              Steel Reinforcement                                                                                                                  Â
Â
ARCHITECTURAL AND FINISHES WORKS
Â
8.            Section-8              Block Masonry                                                                                                                          Â
9.            Section-9              Plastering                                                                                                                                    Â
10.         Section-10            Flooring                                                                                                                                       Â
11.         Section-11            Wooden Doors and Windows                                                                                                 Â
12.         Section-12            Timber Joinery and Hardware                                                                                                Â
13.         Section-13            Aluminum Anodized Doors/Windows and Ventilators                                                      Â
14.         Section-14            False Ceiling                                                                                                                              Â
15.         Section-15            Glass & Glazing                                                                                                                        Â
16.         Section-16            Roof Treatment                                                                                                                           Â
17.         Section-17            Painting / Distempering                                                                                                           Â
18.        Section-18            Color Creting                                                                                        Â
19.         Section-19            Steel Windows, Ventilators, Gates and Grills                                                                      Â
20.         Section-20            Structural Steel Works                                                                                                             Â
PLUMBING WORKS
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
Â
Â
Â
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
|
Number of GC Clause |
Amendments of, and Supplements to, Clauses in the General Conditions of Contract |
|
 |
Definitions The Procuring Agency is: PNSC (CSR), Actg. General Manager Finance FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI The Supplier is: The title of the subject procurement is:REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY |
|
GCC 2 |
Applicable/Governing Law: The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan |
|
GCC 3 |
Language: The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English. |
|
GCC 4 |
Notices: The addresses for the notices are: Procuring Agency: PNSC (CSR), Actg. General Manager Finance Contractor/ Bidder:  [Name, address and telephone number]. The Contractor/ Bidder’s Representative(s) [Name, address, telephone number and e-mail address]  |
|
GCC 6.1 |
The Authorized Representatives are:  For the Procuring Agency: PNSC (CSR), Actg. General Manager Finance For the Bidder: Name: ……………………… Designation: …………….. Address: ……………………………..  |
|
GCC 7 |
Effectiveness of the contract The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties |
|
GCC 8 |
Commencement of Contract: The Contractor/ Bidder shall provide Non-Consultancy Services from the effective date of contract. |
|
GCC 10.2 |
Expiration of Contract: The time period shall be …………………. |
|
GCC 14 |
Termination In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements. |
|
GCC 16 |
Conflict of Interest: The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17. |
|
GCC 20 |
Liquidated Damages If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.10% to 10.00%Â of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority. |
|
GCC 21 |
Performance Guarantee: The amount of performance guarantee shall be 5.00%Â of the contract price in acceptable form of Pay Order, Bank Guarantee |
|
GCC 27 |
Currency of Payment: All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees. |
|
GCC 28 |
Payment terms: Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract. |
| Â | Â |
|
GCC 29 |
Identifying Defects: The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided. Inspections & Tests RequirementsFor being Brand New, bearing relevant reference numbers of the equipment (Certificate from supplier) For Physical Fitness having No Damages (Certificate from supplier) For the Country of Origin as quoted by the Supplier (Certificate from manufacturer) For conformance to specifications and performance parameters, through Prior to delivery inspection (Inspection Report by Inspection Team) For successful operation at site after complete installation, testing and commissioning of the equipment (Installation, Testing and Commissioning Report by Inspection Team) Delivery & DocumentsCopies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount; Original and two copies of the usual transport document (for example, a negotiable bill of lading, a non-negotiable sea waybill, an inland waterway document, an air waybill, a railway consignment note, a road consignment note, or a multimodal transport document) which the buyer may require to take the goods; Copies of the packing list identifying contents of each package; Insurance Certificate; Manufacturer’s or Supplier’s Valid Warranty Certificate; Inspection Certificate issued by the Nominated Inspection Agency (if any), and the Supplier’s Factory Inspection Report; Certificate of Origin. The above documents would be required even if the equipment has already been imported and is available with the supplier ex-stock |
|
GCC 31 Â |
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract unless they otherwise agree that the Authority shall pay the Bidder any monies due to the Bidder. Arbitrator’s fee: The fee shall be specified in Pak Rupees, as determined by the Arbitrator, which shall be shared equally by both parties. Appointing Authority for Arbitrator: By the Mutual Consent or in accordance with the provisions of Arbitration Act, 1940, in case the parties fail to reach a consensus on the name of sole arbitrator, any party may submit an application to the Chief Justice Islamabad High Court for appointment of sole arbitrator. The Chief Justice IHC may appoint a former judge of any High Court or Supreme Court as the sole arbitrator to resolve the dispute between the parties. Rules of procedure for arbitration proceedings: Any dispute between the Authority and a Bidder who is a national of the Islamic Republic of Pakistan arising in connection with the present Contract shall be referred to adjudication or arbitration in accordance with the laws of the Islamic Republic of Pakistan including Arbitration Act 1940, however above provision shall prevail in referring the case to the Arbitrator. Place of Arbitration and Award: The arbitration shall be conducted in English language and place of arbitration shall be at Islamabad. The award of the arbitrator shall be final and shall be binding on the parties. |
Date: [insert date (as day, month and year)]
Bid No.:P36011
To: PNSC (CSR), Actg. General Manager Finance FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI
Â
Â
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred  for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
Â
THIS AGREEMENT made the _____ day of __________ 20_____ between PNSC (CSR), Actg. General Manager Finance FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI
 (hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
Â
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., REPAIR RENOVATION AND REFURBISHMENT OF ADMIN BLOCK, MEDICAL CENTER, PARADE GROUND, SPORTS COMPLEX, SWIMMING POOL & EXAMINATION HALL AT PAKISTAN MARINE ACADEMY (P36011) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
Â
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1.  In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2.  The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3.  In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4.  The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
Â
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Â
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Â
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Â
Witness to the signatures of the Bidder: …………………………………………………
Â
Â
Â
Contract                          Number:  Contract                              Value:  Contract Title:
Dated:
Â
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid  or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
Â
To:     PNSC (CSR), Actg. General Manager Finance FINANCE DEPARTMENT, 12TH FLOOR, PNSC BUILDING, M.T KHAN ROAD, KARACHI
Â
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
Â
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
Â
AND WHEREAS we have agreed to give the Bidders guarantee:
Â
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarÂantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
Â
This guarantee is valid until the: [insert date]
Â
Â
Signature and seal of the Guarantors
Â
Â
_____________________________________________________________________
[name of bank or financial institution]
Â
Â
_____________________________________________________________________
[address]
Â
Â
_____________________________________________________________________
[date}
Project Drawings
Detailed Technical Specification of project
Detailed BOQ