In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator
Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
+92-331-506-6282
usamakausar.062@gmail.com
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: FPPRA (Federal Public Procurement Regulatory Authority (PPRA)) The subject of procurement is: CDA TEST Procurement Expected commencement date: Wednesday, August 19, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P54935 |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Monday, July 20, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on FPPRA (Federal Public Procurement Regulatory Authority (PPRA)) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid: No |
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 180 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Call at Deposit |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Tuesday, August 4, 2026 03:00 PM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Tuesday Date: August 04, 2026 Time : 03:30 PM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 0%. The Performance Guarantee shall be acceptable in the form of: Nil |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Any | None |
Least Cost Based Selection (LCBS)
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 40 | |
| Technical Evaluation Criteria | ||
| Technical Evaluation Criteria (Quantitative)(Doc Required) | 100 | |
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| CDA | Address: Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory Schedule: 27 Days Quantity: 1/hectare |
1/hectare | 369368 PKR |
| Item | UNSPSC | Delivery Schedule | Quantity | Bid Security | Related to Job/Lot |
|---|---|---|---|---|---|
| Test | Acadesine |
Address: Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
Schedule: 27 Days
Quantity: 22/Qty
|
22/Qty | 22800000000 PKR | CDA (Job) |
No
Jobs Without Lots :
Job: CDA
Specifications / Requirements:
| Sr. No | Ref. No. | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|---|
| 1 | 21-1(b) (ii) | Excavation in foundation of building, bridges and other structures,including dagbelling, dressing, refilling around structure with excavated earth, watering and ramming lead upto one chain (30 m) and lift upto 5 ft.(1.5m) b) By Excavator. ii) in ordinary soil. | 1000 Cft. | 225 | 10738.9 | 2416252.5 |
| 2 | 21-2 (ii) | Lift from 5ft (1.5m) to 15 ft (4.5 m):- ii) Ordinary soil | 1000 Cft. | 675 | 13017.6 | 8786880 |
| 3 | 21-2 (b) | Lift above 15 ft (4.5 m):- ii) in ordinary soil. | 1000 Cft. | 270 | 15215.1 | 4108077 |
| 4 | 5 (f) + ( 1 of Ch-1) | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate): including lead up to 30 km ( 47976.70 + 2208 ) (f) Ratio 1:2: 4 | 100 Cft | 355 | 50184.7 | 17815568.5 |
| 5 | (h) + (1 of CH-1) | (h) Ratio 1:3: 6 (40804.30 + 2318.40 ) | 100 Cft | 10 | 43122.7 | 431227 |
| 6 | (i) + (1 of CH-1) | (i) Ratio 1: 4: 8 ( 35568.70 + 2377.8 ) | 100 Cft | 270 | 37946.5 | 10245555 |
| 7 | 9 | Placing, compacting, finishing and curing of concrete using Ordinary Portland Cement / Sulphate resisting cement / Slag cement as may be required; including screening, washing of aggregates and mixing of constituents using batching plant, Transportation by transit mixer, pouring with pump in the required proportions to achieve a nominal cylindrical strength in the field as per ACI 214, with the specified consistency. i/c the cost of shuttering, compaction with Viberator, excluding the cost of Admixture, as approved and directed by the Engineer Incharge including lead up to 30 km | ||||
| 8 | c) + (1 of CH-1) | Substructure (Foundations, Raft, Strip and Footing Beams) (vi) 3000 PSI | Per Cft | 130209 | 584.63 | 76124087.67 |
| 9 | a) + (1 of CH-1) | in roof slab, beams, lintels, girders and other structural members (vi) 3000 PSI | Per Cft | 131624 | 729.28 | 95990750.72 |
| 10 | a) + (1 of CH-1) | Superstructure (Columns and others requiring formwork) (iv) 4000 PSI | Per Cft | 35578 | 826.93 | 29420515.54 |
| 11 | b) + (1 of CH-1) | Retaining/ Shear walls laid in situ or precast laid in position. iv) 4000 PSI (ii) More Than 9" Thick | Per Cft | 26850 | 713.03 | 19144855.5 |
| 12 | 12 (b) | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars):- (ii) Deformed bars (Grade-60) | 100 kg | 17023 | 28479.6 | 484808230.8 |
| 13 | 5 (i) + 6 (ii) | i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 21.75 | 46208.85 | 1005042.4875 |
| 14 | BRICK WORK (in Upper Basement) | |||||
| 15 | 5 (i) + 6 (i) | i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 21.45 | 43975.4 | 943272.33 |
| 16 | 5 (i) | BRICK WORK (Ground Floor) | ||||
| 17 | Pacca brick work ground floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 104.5 | 42181.95 | 4408013.775 | |
| 18 | 5 (i) + 6 (i) | BRICK WORK (1st Floor) | ||||
| 19 | Pacca brick work in 1st floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 122.85 | 43975.4 | 5402377.89 | |
| 20 | 5 (i) + 6 (ii) | BRICK WORK (2nd Floor) | ||||
| 21 | Pacca brick work in 2nd floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 128.34 | 46208.85 | 5930443.809 | |
| 22 | 5 (i) + 6 (iii) | BRICK WORK (3rd Floor) | ||||
| 23 | Pacca brick work in above 2nd floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 99.4 | 48442.25 | 4815159.65 | |
| 24 | 5 (i) + 6 (iv) | BRICK WORK (4th Floorfloors) | ||||
| 25 | Pacca brick work in above 2nd floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 104.55 | 52232.45 | 5460902.6475 | |
| 26 | 5 (i) + 6 (v) | BRICK WORK (5th & subsequent floors) | ||||
| 27 | Pacca brick work in above 2nd floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 214.2 | 53308.5 | 11418680.7 | |
| 28 | 35 | Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen,complete in all respect iii) Thermopore sheet 1" (25 mm) thick | 100 Sft | 88.23 | 19751.6 | 1742683.668 |
| 29 | 15 | Khuras on roof 2'x2'x6" (600 x 600 x 150 mm) | Each | 10 | 1228.55 | 12285.5 |
| 30 | 57 (b) | Providing and fixing ornamental wooden architrave 3" x (1½" tapered to ¼") all along the door frame complete in allrespect. (b) Deodar wood architrave | Per Sft | 9083 | 153.8 | 1396965.4 |
| 31 | 17 | Providing and fixing 2" wide MS Chowkat singel/double rebate made of 16 SWG MS sheet pressed/welded/supported with M.S.flat1-1/4"x1/8" i/c 6" long M.S. Flat 1"x1/8" hold fasts (6-Nos) welded/screwed, punching of lock hole covered with MS Box, coating with anti rust paint including filling with cement sand mortar (1:8) and embedding holdfast in cemen tconcrete (1:2:4) ,complete in all respect as approved and directed by Engineer Incharge. | ||||
| 32 | (ii) | 10.50 " wide | Per Sft | 2290 | 731.35 | 1674791.5 |
| 33 | (iii) | 5.5 " wide | Per Sft | 1240 | 530.45 | 657758 |
| 34 | 5 | Providing and fixing 1st class solid wood wrought joinery in panelled or panelled and glazed doors and windows of specified thickness with 1" thick solid wood panels with step and 1-1/2"x2-1/2" beadings all around the panels i /c the cost of Tower bolt and handles compl ete in all respect (Excluding the cost of sliding bolt,lock and chowkats (frame), etc.) as approved and directed by the Engineer Incharge. b) Ash wood Door (iii) 1-1/2" thick (40 mm) | Per Sft | 3540 | 3287.65 | 11638281 |
| 35 | 60 | P/F 3/4" dia heavy duty sliding bolt of specified materi al i /c the cost of hardware complete in all respect as approved and directed by the Engineer Incharge. b) Brass i ) 10" (250 mm) l ong | Each | 195 | 1058.5 | 206407.5 |
| 36 | 62 | Providing and fixing automatic hydraulic operated door closer imported heavy duty complete in all respect as approved and directed by the Engineer Incharge. | Each | 125 | 5027 | 628375 |
| 37 | 64 | Providing and fixing Imported Mortice Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge. | Each | 195 | 4569.55 | 891062.25 |
| 38 | 3 | Supplying and filling sand under floor; or plugging in wells. | 100 Cft | 428.4 | 4156.7 | 1780730.28 |
| 39 | 39 | Providing and laying 1" thick terrazzo tile for specified colour & size full body, best quality with minimum 5000 PSI in approved design with adhesive bond over 3/4" thick 1:3 cement plaster i/c the cost of sealer for finishing the joints i/c cutting, grinding, rubbing, filling. Complete in all respect as approved and directed by the Engineer incharge. (Without Polishing) b) Size 24"x24"x1" ii) Coloured | P.Sft | 89760 | 450.05 | 40396488 |
| 40 | 25 (b) | Rubbing and polishing grit floor, including repairing voids, uneven surface, complete in all respects | 100 Cft | 897.6 | 4838.2 | 4342768.32 |
| 41 | 23 | Providing and laying superb quality Ceramic tile floors of Master brand of specific size, Glossy/Matt/ Texture of approved Color and Shade as per approved design with adhesive bond, over 3/4" thick (1;2) cement sand plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respects and as approved and directed by the Engineer Incharge. | ||||
| 42 | (i) | 12"x18"/12"x24"/10"x24" /8"x24"/12"x36" | Per Sft | 4102 | 306.9 | 1258903.8 |
| 43 | 24 | Providing and laying superb quality Ceramic tiles dado of Master brand of specified size, Glossy/Matt/Textures kirting/dado of approved Color and Shade with adhesive bond over1/2" thick (1:2) cement plaster i/c the cost of sealer for finishing the jointsi/ccutting, grinding complete in all respects as approved and directed by theEngineerIncharge | ||||
| 44 | (i) | 12"x18"/12"x24"/10"x24" /8"x24"/12"x36" | Per Sft | 19075 | 307.15 | 5858886.25 |
| 45 | 36 | Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of matching sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge a) Full body Glazed tiles | ||||
| 46 | (iii) | 600mm x 600 mm | Per Sft | 57400 | 450.8 | 25875920 |
| 47 | 33 | Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: a) New surface: | ||||
| 48 | (i) | i) 1st coat | 100 Sft | 207.9 | 5011.15 | 1041818.085 |
| 49 | (ii) | 2-Coats & Subsequent Coat | 100 Sft | 207.9 | 2778.55 | 577660.545 |
| 50 | 41 | Extra labour for painting, varnishing, etc. from 20' (6.10 m) height and above, for every additional 10' (3.05 m) height, or part thereof, requiring scaffolding. (2 x 3 x 259.85)=1559.10 %sft | 100 Sft./ Coat | 140.7 | 1559.1 | 219365.37 |
| 51 | 9 | Cement plaster 1:4 upto 20' (6.00 m) height:- b) ½" (13 mm) thick | 100 Sft | 4236 | 4923.45 | 20855734.2 |
| 52 | 39 | Preparing surface and applying GraffiatoWeathe rCoating (Co-polymer emulsion) of approved colour & shade with weather resistant pigment, highly water repellant with Metalic Spatula having top class finish by smoothing with a plastic Spatula, on a base coat (Primer) over well cleaned plastered surface complete in all respect as approved and directed by the Engineer Incharge. | Per Sft | 42185 | 86.45 | 3646893.25 |
| 53 | 10 | Fabrication of heavy steel work, with angle, tees, flat ironround iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, but excluding erection in position. | 100 Kg | 465.5 | 35334.3 | 16448116.65 |
| 54 | 33 | Providing and fixing stair railing (all types and designs) of hard wood, including bends and corners, screwed to 5/8"x5/8" (16x16 mm) M.S. square bars 2.75 ft. (838 mm) high, at 5.5 inch (137 mm) inch centre to centre, fixed in steps of stairs, M.S. flat 1"x1/8" (25x3 mm) welded to bars, painting/polishing 3 coats, etc. complete. | Per Rft | 1052 | 2590.2 | 2724890.4 |
| 55 | 61 | P/F Iron door comprising of specified leaves made of 1-1/4”x1-1/4”x3/16" MS angle iron for leaf frame, diagonal and horizontal braces duly welded with MS. sheet 18-SWG i/c the cost of sliding bolt, tower bolt and painting 3-coats but excluding the cost of Chowkat complete in all respect as approved and directed by the Engineer incharge. (ii) Double Leaf | Per Sft | 128 | 1480.8 | 189542.4 |
| 56 | 43 | Spraying anti termite proofing by using liquid FMC Biflex 2.5%EC Mixing Ratio 1:50=137-Sft or using liquid MIRAGE Ali Akbar /RANGERS Auriga 5% SC Mixing Ability-HEXTAR Ratio 1:110=205-Sft or any other equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge. | Per Sft | 47250 | 12.7 | 600075 |
| 57 | UPVC WINDOWS | |||||
| 58 | Non Schedule | Providing and fixing factory made uPVC (Full Body Gray/Black color with outside PMMA (co extruded coating) sliding glazed window/ventilators comprising of uPVC multi-chambered frame with aluminium roller track and sash extruded profiles of Yingde Conch Profiles Co Ltd / Dimex or approved equivalent, Three track three panels sliding window with fly proof wire mesh (Two nos. glazed & one no. wire mesh panels) made of (series) frame 88x52 mm & sash 42x66mm & 21x52mm mesh Sash and single glazing bead / double glazing bead of appropriate dimension duly reinforced with 1.2 ± 0.1 mm thick galvanized mild steel section of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, Silicone fin wool pile, zinc alloy (Black powder coated) Handle with espagnolette (multipoint lock) lock, metal frame nylon rollers .Nylon Frame fixing anchors 80x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (without Glass) (Before Execution contractor shall submit the shop drawings, samples, design calculation and fixing detail etc for Consultant's approval.) | Sft | 5200 | 2405 | 12506000 |
| 59 | Non Schedule | Providing and fixing factory made uPVC (Full Body Gray/black color with outside PMMA co extruded Coating) Fully Fix glazed window comprising of uPVC multi-chambered frame extruded profiles of Yingde Conch Profiles Co Ltd / Dimex or approved equivalent frame 60x58mm & 60x72mm Mullion and single glazing bead / double glazing bead of appropriate dimension duly reinforced with 1.2 ± 0.1mm thick galvanized mild steel section of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads .EPDM gasket. Nylon Frame fixing anchors 80x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. without Glass. (Before Execution contractor shall submit the shop drawings, samples, design calculation and fixing detail etc for Consultant's approval.) | Sft | 1200 | 1300 | 1560000 |
| 60 | Non Schedule | Providing and fixing factory made uPVC ( Full Body Gray color with outside PMMA co extruded Coating) casement/Casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles of Yingde Conch Profiles Co Ltd / Dimex or approved equivalent made of (series) frame 60x58 mm & sash 60x78mm & 72x60mm Mullion and single glazing bead / double glazing bead of appropriate dimension duly reinforced with 1.2 ± 0.2 mm thick galvanized mild steel section required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, Hinges, Stay EPDM gasket, zinc alloy (Black powder coated) handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, Nylon Frame fixing anchors 80x8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. without Glass (Before Execution contractor shall submit the shop drawings, samples, design calculation and fixing detail etc for Consultant's approval.) | Sft | 660 | 2145 | 1415700 |
| 61 | Non Schedule | Providing and fixing Single Glaze Solar Control/Low-e Tempered 6mm Glass of approved quality, color for window/Doors/ventilators complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Sft | 7060 | 975 | 6883500 |
| 62 | Floor Cabinets | |||||
| 63 | Non Schedule | Providing & Fixing of floor cabinet 600mm wide & 862mm high with First class Soft wood (deodar) frame, 2 1/2" x 1 1/4'' thick 3/4" thick lamination board (local) shutter /drawer of approved colour/design incl all necessary chromium plated (cp) mongery, PVC beading,RCC slab, 25mm thick 625 mm wide white/ coloured marble slab, PCC in side, complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Sft | 480 | 1378 | 661440 |
| 64 | Wall Cabinets | |||||
| 65 | Non Schedule | Providing & Fixing of kitchen wall cabinets 381mm wide & 610mm high with first class Soft wood (deodar) frame, size 2 1/2''x1 1/2'' thick lamination (local) board shutter of approved colour/design incl all necessary CP mongery fixture, & PVC beading complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Sft | 390 | 1185 | 462150 |
| 66 | WPC DOORS | |||||
| 67 | Non Schedule | Providing and Fixing Factory made single panel extruded 37-38mm WPC(wood polymer composite) door shutter/frame/beading of required size, shape, and design of 5mm thickness. Comprising of Pure polymer, calcium carbonate and natural fiber wood powder/rice husk/wheat husk and non toxic additives having specific gravity value 1.07% and Tensile strength 10.3 MPa flexural strength of 23-24 MPa and resisting to spread flame with property of being termite/borer proof, water/moisture proof fire retardant. Fixing with stainless steel hinges of required sizes and full body threaded star head counter sunk SS screws. Door shutter Hinges and lock side reinforce with best guilty wood pieces with 4nos bars in each door shutter and sealed all sides with wpc strip. Door frame(chokht) fix to wall with anchors in back filled with PU Foam. including the cast of Enamal paint/Polish, Tower Bolt & Door stopper etc complete in all respect as per Specifications and instruction of the engineer In- Charge | Sft | 1420 | 2450 | 3479000 |
| 68 | PAINTING ON PLASTERED WALLS /CEILING ETC | |||||
| 69 | Non Schedule | Providing & applying 3- coats of spot less Emulsion paint of approved make , color (stain repellent) at any height/floor incl preparation of surface with 3-coats of ACS putty, one coat of sealer on plastered walls including rubbing, finishing the surfaces, complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Sft | 390885 | 75 | 29316375 |
| 70 | Gypsum Board Ceiling | |||||
| 71 | Non Schedule | Providing and fixing water proof PVC Laminated with foil backing Gypsum Board Tiles size 24" x 24" x 1/2" ceiling with complete fixing mechanism of aluminium tees, angles, hanging wire, hooks, clips etc. foresee location of light fixtures, A/C & other services complete in all respect as per drawings, Technical Provisions and or as directed by the Engineer. | Sft | 153144 | 170 | 26034480 |
| 72 | 3 | Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge. A) Two Piece ii) PORTA HD 200N Toilet Cito with Hydraulic Seat Cover | Each | 45 | 61651.1 | 2774299.5 |
| 73 | 4 | Providing and fitting glazed earthen ware water closet, squatter type (Orisa pattern), combined with foot rest. i) white | Each | 17 | 6949.6 | 118143.2 |
| 74 | 7 (i) | Providing and fitting glazed earthen ware wash hand basin 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc. i) white, with pedestal | Each | 10 | 12051.55 | 120515.5 |
| 75 | (v) | (v) Under Counter Vanity Basin | Each | 62 | 13047.55 | 808948.1 |
| 76 | 8 | Providing and fixing stainless steel sink with drain board, size 120x60 cm (48"x24") including bracket set, waste pipe and waste coupling. | Each | 8 | 15806.95 | 126455.6 |
| 77 | 16 | Providing and fixing, chromium plated soap dish. | Each | 60 | 981.6 | 58896 |
| 78 | 18 | Providing and fixing, chromium plated toilet paper holder. | Each | 65 | 1271.45 | 82644.25 |
| 79 | 19 | Providing and fixing, chromium plated towel rail:- i) 60 cm (24") long, and 2 cm (¾") dia. | Each | 30 | 1337.2 | 40116 |
| 80 | 21 | Providing and fixing glass shelf 60x13 cm (24"x5"), with 5mm thick glass:- i) with chromium plated brackets and railing | Each | 30 | 1701.7 | 51051 |
| 81 | 24 | Providing and fixing chromium plated pillar-cock, heavy:- i) 2 cm (¾") | Each | 80 | 3928 | 314240 |
| 82 | 27 | Providing and fixing chromium plated bib cock:- i) 2 cm (¾") | Each | 30 | 1828 | 54840 |
| 83 | 28 | Providing and fixing chromium plated tee stop cock 15mm (½"). | Each | 206 | 2068 | 426008 |
| 84 | 30 | Providing and fixing, chromium plated mixing valve, for wash hand basin, sink or shower. | Each | 4 | 3950 | 15800 |
| 85 | 31 | Providing and fixing gun metal peet/gate valve (screwed):- iii) 50 mm(2") dia | Each | 13 | 12132 | 157716 |
| 86 | 40 | Supply and fitting of cast iron manhole cover with frame, etc. complete. i) 30 cm (12") dia | Each | 50 | 2532 | 126600 |
| 87 | ii) 45 cm (18") dia | Each | 35 | 3492 | 122220 | |
| 88 | 44 (a) | Providing and fixing, brass gas cock:- a) 15 mm (½") dia | Each | 150 | 793.75 | 119062.5 |
| 89 | (b) | Providing and fixing, brass gas cock:- b) 20 mm (3/4") dia | Each | 45 | 1021.75 | 45978.75 |
| 90 | 47 | Providing, fixing, testing and commissioning of µ-PVC (Unplasticized Polyvinyl Chloride ) Nikasi/ SWV pipe, Dadex / Popular / Beta or approved equivalent manufacturer, plain / Bell Ended / Z - Joints conforming to BS 4514 / BS 5255 - EN 1329 including the cost of specials and Solvents complete in all respects, as per drawings & specifications and / or as approved and directed by the Engineer Incharge. | ||||
| 91 | (iv) | (82 mm ) | Per Rft | 8500 | 160.6 | 1365100 |
| 92 | (v) | (110 mm) | Per Rft | 7500 | 254.3 | 1907250 |
| 93 | (vi) | (160 mm) | Per Rft | 3750 | 493.4 | 1850250 |
| 94 | (vii) | (200 mm) | Per Rft | 2250 | 525.65 | 1182712.5 |
| 95 | 49 | Providing, fixing, testing and commissioning of μ-PVC (Un plasticized poly vinyl Chloride) Nikasi/wastepipe Fittings make of dadex/Popular/Beta/BBJ conforming to code EN-1401encluding the cost of Solvents complete in all respectas approved and directed by the Engineer Incharge. (b) Multi-Trap | ||||
| 96 | (i) | 4" dia | Each | 62 | 1436.1 | 89038.2 |
| 97 | (ii) | 3" dia | Each | 78 | 1046.1 | 81595.8 |
| 98 | 52 (v) | Providing and fixing1/2"dia Muslim Shower of Fasial/Master comprising of 1/2"dia one-meter long rubber/CP fexible pipe and hand shower set complete in all respects as approved and directed by the Engineer Incharge.Providing and fixing CP bath Room Set made of Sonex /Master /Faisal comprising o f3-No Tee stop cocks, leverty pe Basin Mixer,double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge (v) Muslim shower | Each | 62 | 2387 | 147994 |
| 99 | (iii) | (iii) Double Bib Cock | Each | 62 | 1907 | 118234 |
| 100 | (iv) | (iv) Open Type Wall Shower | Each | 5 | 18707 | 93535 |
| 101 | 1 | Providing and laying R.C.C. pipe, moulded with cement concrete 1:1½:3, with spigot socket or collar joint, etc including cost of reinforcement, conforming to B.S. 5911:Part I: 1981, Class "L" including carriage of pipe from factory to site of work, lowering in trenches to correct alignment and grade, jointing, cutting pipes where necessary, finishing and testing, etc., complete. iii) 225 mm (9:) i/d | Rft | 1750 | 606.75 | 1061812.5 |
| 102 | 5 | Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects. b) concrete Gully trap | Each | 19 | 7079.95 | 134519.05 |
| 103 | 16 | Providing and fixing 6" thick R.C.C. manhole cover with tee shaped C.I. frame of 22" I/d (frame weighing 37.324 Kg. or one maund as per Standard Drawing STD/PD No. 6, of 1977, complete in all respect. | Per Set | 19 | 11263.6 | 214008.4 |
| 104 | 19 | Providing, laying, cutting, jointing, testing and disinfecting G.I. pipe line in trenches, with socket joints, using G.I.pipes of B.S.S. 1387-1967 complete in all respects, with specials and valves. A) With Socket Joints 2) Medium Quality | ||||
| 105 | (ii) | ¾" i/d (20 mm) 2.65mm thick | Per Rft | 6500 | 287.3 | 1867450 |
| 106 | (iii) | 1" i/d (25 mm) 3.25mm thick | Per Rft | 1750 | 430.55 | 753462.5 |
| 107 | (vi) | 2" i/d (50 mm) 3.65mm thick | Per Rft | 5800 | 872.7 | 5061660 |
| 108 | (ix) | 4" i/d (100 mm) 4.5mm thick | Per Rft | 1100 | 1999.25 | 2199175 |
| 109 | 33 | Providing,laying,testing and commissioning of POLY PROPYLENE RANDOM COPOLYMER (PPRC) water supply pipe made of (Dadex/Popular/Beta/BBJ) with specified pressure rating PN (PRESSURE NOMINAL) and conforming to DIN8077-8078 codei/ccost of solvent,specials,making jharries complete inall respect as approved and directed by Engineer Incharge. (Internal/ External Diameters mentioned). b) PN-20 pipe | ||||
| 110 | (ii) | (3/4") 25 mm | Per Rft | 1850 | 99.7 | 184445 |
| 111 | (iii) | (1") 32 mm | Per Rft | 5800 | 158.25 | 917850 |
| 112 | (iv) | (1-1/4") 40 mm | Per Rft | 2500 | 241.75 | 604375 |
| 113 | (v) | (1-1/2") 50 mm | Per Rft | 1650 | 347.1 | 572715 |
| 114 | (vi) | (2") 63 mm | Per Rft | 1500 | 541.3 | 811950 |
| 115 | (vii) | (2-1/4") 75 mm | Per Rft | 1150 | 798.05 | 917757.5 |
| 116 | 48 | Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities /Shelves /Treads / Window Cills,having Uniform texture (Spotless ) with adhesive bond over 3/4" thick (1:2) cemen sand mortor i/c the cost of matching sealer complete in all respect as approved and directed by the Engineer Incharge. i) China Verona | Per Sft | 275 | 642.35 | 176646.25 |
| 117 | 9 | Placing, compacting, finishing and curing of concrete using Ordinary Portland Cement / Sulphate resisting cement / Slag cement as may be required; including screening, washing of aggregates and mixing of constituents using batching plant, Transportation by transit mixer, pouring with pump in the required proportions to achieve a nominal cylindrical strength in the field as per ACI 214, with the specified consistency. i/c the cost of shuttering, compaction with Viberator, excluding the cost of Admixture, as approved and directed by the Engineer Incharge including lead up to 30 km | ||||
| 118 | a) + (1 of CH-1) | in roof slab, beams, lintels, girders and other structural members (vi) 3000 PSI | Per Cft | 10500 | 729.28 | 7657440 |
| 119 | a) + (1 of CH-1) | Superstructure (Columns and others requiring formwork) (iv) 4000 PSI | Per Cft | 7500 | 826.93 | 6201975 |
| 120 | b) + (1 of CH-1) | Retaining/ Shear walls laid in situ or precast laid in position. iv) 4000 PSI (ii) More Than 9" Thick | Per Cft | 1365 | 713.03 | 973285.95 |
| 121 | 12 (b) | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars):- (c) Deformed bars (Grade-60) | 100 kg | 210.323 | 28479.6 | 5989914.9108 |
| 122 | EXCAVATION | |||||
| 123 | 21-1(b) (ii) | Excavation in foundation of building, bridges and other structures,including dagbelling, dressing, refilling around structure with excavated earth, watering and ramming lead upto one chain (30 m) and lift upto 5 ft.(1.5m) b) By Excavator ii) in ordinary soil. | 1000 Cft. | 5.5 | 10738.9 | 59063.95 |
| 124 | 21-2 (ii) | Lift from 5ft (1.5m) to 15 ft (4.5 m):- ii) Ordinary soil | 1000 Cft. | 4.35 | 13017.6 | 56626.56 |
| 125 | 9 | Cement plaster 1:4 upto 20' (6.00 m) height:- b) ½" (13 mm) thick | 100 Sft | 15.5 | 4923.45 | 76313.475 |
| 126 | 10 | Fabrication of heavy steel work, with angle, tees, flat ironround iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, but excluding erection in position. | 100 Kg | 25 | 35334.3 | 883357.5 |
| 127 | Non Schedule | Proiding and fixing of mirror any shape and pattern, circular, rectangular, oval etc 5 mm thick, imported (mirror foreign made) including cost of edging, fixing accessories complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Sft | 435 | 425 | 184875 |
| 128 | Non Schedule | Proiding and fixing of casted grating CP 4"x4" complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 185 | 592 | 109520 |
| 129 | Non Schedule | Proiding and fixingof Non return valveor reflux valve, screwed 3/4" dia, complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 10 | 1470 | 14700 |
| 130 | Non Schedule | Proiding and fixing of Air valve automatic, 2" size, double acting complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 8 | 3160 | 25280 |
| 131 | 3 | Boring for tubewell in shingle, gravel and rock, including sinking and withdrawing of casing pipe:- | ||||
| 132 | a) | From ground level to 200 ft. (60 m) below ground level:- i) 12" to 18" (300 to 450 mm) i/d | Rft of bore | 200 | 1991.5 | 398300 |
| 133 | b) | Exceeding 200 ft. (60 m) depth below ground level:- i) 12" to 18" (300 to 450 mm) i/d | Rft of bore | 450 | 2190.65 | 985792.5 |
| 134 | 4 | Providing strong substantially built box of deodar wood 4'x2½'x9" (1200x750x225 mm), with compartments, lock and locking arrangement for preserving samples of strata from bore hole. | Job for complete Bore | 1 | 43572.85 | 43572.85 |
| 135 | 5 | Furnishing sample of water from bore hole. | P. Set of 2 bottles | 5 | 232.75 | 1163.75 |
| 136 | 9 | Providing and installing Fiberglass Reinforced Polypropelene (FRP) strainer of specifid wall thickness having slot size of 0.9 mm to 1.10 mm in Tubewell borehole i/c the cost of male/female coupling with Nylone Strip,studs complete in all respect as approved and directed by the Engineer Incharge. vi) 10" inch dia (6.35 mm thickness) | Rft | 200 | 4030.4 | 806080 |
| 137 | 11 | Providing and installing P.V.C. Bail/End plug, in tubewell bore hole:- a) B.S.S. Class `B' vi) 10" i/d (250 mm) | Each | 1 | 782.35 | 782.35 |
| 138 | 12 | Providing and installing M.S. blind pipe socketed/welded joint, M.S reducer (where necessary), in tubewell bore hole, including jointing/ welding with strainer, etc. complete:- i) 10" i/d, ¼" (250 mm i/d 6 mm) thick | Rft | 460 | 5120.6 | 2355476 |
| 139 | 16 | Testing and developing of tubewell of size 6" (150 mm) i/d and above continuously. i) upto 1.5 cs. discharge | P. Hour | 12 | 2681.3 | 32175.6 |
| 140 | 17 | Shrouding with graded pea gravel 3/8" to 1/8" (10 to 3 mm), around tubewell in bore hole. | Per Cft. | 500 | 189.3 | 94650 |
| 141 | 31 | Providing & mixing bentonite clay / powder have swelling factor of 1200% for lining /seal and plug earthen bore holes/ponds in the specified ratio conforming to IS:6186 for stabilization of soil as specified by the designer etc complete in all respect. | P. Pound | 500 | 13.2 | 6600 |
| 142 | 42 | Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK), Scon (Pakistan) or approved quivalent manufacturer, i/c the cost of all accessories flanges,nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge. (b) Flange Ended Ductile Iron Valve (ix) 4" dia | Each | 4 | 30780 | 123120 |
| 143 | 19 | Providing, laying, cutting, jointing, testing and disinfecting G.I. pipe line in trenches, with socket joints, using G.I.pipes of B.S.S. 1387-1967 complete in all respects, with specials and valves. A) With Socket Joints 2) Medium Quality | ||||
| 144 | (ix) | 4" i/d (100 mm) 4.5mm thick | Per Rft | 650 | 1999.25 | 1299512.5 |
| 145 | 44 | Providing and fixing heavy duty Check Valve of specified diameter and material for pressure rating PN-16 made of Crane (USA), Hatersly (UK), Scon (Pakistan) or approved equivalent manufacturer i/c the cost of all accessories flanges,nut/bolt and gaskit where required complete in all Providing and fixing heavy duty Check Valve of specified diameter and respect as approved and directed by the Engineer Incharge. | ||||
| 146 | i) | (a) Brass Threaded Valves (vi) 2" dia | Each | 8 | 13420.8 | 107366.4 |
| 147 | ii) | (b) Flange Ended Ductile Iron Valve (ix) 4" dia | Each | 4 | 13346.4 | 53385.6 |
| 148 | 9 | Placing, compacting, finishing and curing of concrete using Ordinary Portland Cement / Sulphate resisting cement / Slag cement as may be required; including screening, washing of aggregates and mixing of constituents using batching plant, Transportation by transit mixer, pouring with pump in the required proportions to achieve a nominal cylindrical strength in the field as per ACI 214, with the specified consistency. i/c the cost of shuttering, compaction with Viberator, excluding the cost of Admixture, as approved and directed by the Engineer Incharge including lead up to 30 km | ||||
| 149 | a) + (1 of CH-1) | in roof slab, beams, lintels, girders and other structural members (vi) 3000 PSI | Per Cft | 10500 | 729.28 | 7657440 |
| 150 | a) + (1 of CH-1) | Superstructure (Columns and others requiring formwork) (iv) 4000 PSI | Per Cft | 7500 | 826.93 | 6201975 |
| 151 | b) + (1 of CH-1) | Retaining/ Shear walls laid in situ or precast laid in position. iv) 4000 PSI (ii) More Than 9" Thick | Per Cft | 1365 | 713.03 | 973285.95 |
| 152 | 12 (b) | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars):- (c) Deformed bars (Grade-60) | 100 kg | 210.323 | 28479.6 | 5989914.9108 |
| 153 | 21-1(b) (ii) | Excavation in foundation of building, bridges and other structures,including dagbelling, dressing, refilling around structure with excavated earth, watering and ramming lead upto one chain (30 m) and lift upto 5 ft.(1.5m) b) By Excavator ii) in ordinary soil. | 1000 Cft. | 5.5 | 10738.9 | 59063.95 |
| 154 | 21-2 (ii) | Lift from 5ft (1.5m) to 15 ft (4.5 m):- ii) Ordinary soil | 1000 Cft. | 4.35 | 13017.6 | 56626.56 |
| 155 | 9 | Cement plaster 1:4 upto 20' (6.00 m) height:- b) ½" (13 mm) thick | 100 Sft | 15.5 | 4923.45 | 76313.475 |
| 156 | 10 | Fabrication of heavy steel work, with angle, tees, flat ironround iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, but excluding erection in position. | 100 Kg | 25 | 35334.3 | 883357.5 |
| 157 | Non Schedule | Supply and installation of sentrifugal pump set with A.C electric motor, 400 v, 3-phase, 50 cycles, motor and pump , motor control unit directly coupled and mounted on commen bed plate/ channel base, duly aligned, head 35 M, capacity above 300 up to 550 gpm, 1450 rpm, with anchoring bolts/nuts, complete in all respects as per drawings technical provisions and instructions of the Engineer Incharge. | Each | 2 | 650000 | 1300000 |
| 158 | Non Schedule | Supply & installing of pumping set submersible with AC electric motor driven, 400 volts 3 phase, 50 cycles, complete with pump, motor, cable, column pipes, motor control unit, pump capacity 0.5 to o.75 cusec up to 100 M head with 30 hp motor, 2900 rpm complete in all respects as per drawings, technical provisions and instructions of the Engineer Incharge. | Each | 1 | 3686200 | 3686200 |
| 159 | 21-1(b) (ii) | Excavation in foundation of building, bridges and other structures,including dagbelling, dressing, refilling around structure with excavated earth, watering and ramming lead upto one chain (30 m) and lift upto 5 ft.(1.5m) b) By Excavator ii) in ordinary soil. | 1000 Cft. | 2.5 | 10738.9 | 26847.25 |
| 160 | 5 (f) + ( 1 of Ch-1) | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate): including lead up to 30 km ( 35568.70 + 2377.8 ) (i) Ratio 1:4: 8 | 100 Cft | 10.5 | 37946.5 | 398438.25 |
| 161 | 9 | Placing, compacting, finishing and curing of concrete using Ordinary Portland Cement / Sulphate resisting cement / Slag cement as may be required; including screening, washing of aggregates and mixing of constituents using batching plant, Transportation by transit mixer, pouring with pump in the required proportions to achieve a nominal cylindrical strength in the field as per ACI 214, with the specified consistency. i/c the cost of shuttering, compaction with Viberator, excluding the cost of Admixture, as approved and directed by the Engineer Incharge including lead up to 30 km | ||||
| 162 | c) + (1 of CH-1) | Substructure (Foundations, Raft, Strip and Footing Beams) (vi) 3000 PSI | Per Cft | 530 | 584.63 | 309853.9 |
| 163 | a) + (1 of CH-1) | in roof slab, beams, lintels, girders and other structural members (vi) 3000 PSI | Per Cft | 450 | 729.28 | 328176 |
| 164 | a) + (1 of CH-1) | Superstructure (Columns and others requiring formwork) (iv) 4000 PSI | Per Cft | 375 | 826.93 | 310098.75 |
| 165 | 12 (c) | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars):- (c) Deformed bars (Grade-60) | 100 kg | 10 | 28479.6 | 284796 |
| 166 | 40 | Providing and fixing collapsible gate made of 2"x2"x"¼ (50x50x6 mm) tee iron at top and bottom, channel iron verticals ¾"x¼"x¼"x1/8" (20x6x6x3 mm) at 3" (75 mm) to 5" (125 mm) centre to centre (approximate) and flat iron crosses 3"x3/16" (75x5 mm), and best quality rollers at bottom of 3" (75 mm) diameter including holdfasts,handles 12" (300 mm) ong of ¾"x¼"x¼"x1/8" (20x6x6x3 mm) channel iron, locking arrangement inside andoutside, painting 3 coats of black Japan enameled, complete in working order. | Per Sft | 240 | 1996 | 479040 |
| 167 | 4 (i) | Pacca brick work in foundation and plinth in:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 4.5 | 41153.25 | 185189.625 |
| 168 | 5 (i) | Pacca brick work ground floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 2.5 | 42181.95 | 105454.875 |
| 169 | 9 | Cement plaster 1:4 upto 20' (6.00 m) height:- b) ½" (13 mm) thick | 100 Sft | 45 | 4923.45 | 221555.25 |
| 170 | 33 | Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: a) New surface: | ||||
| 171 | (i) | i) 1st coat | 100 Sft | 50 | 5011.15 | 250557.5 |
| 172 | (ii) | 2-Coats & Subsequent Coat | 100 Sft | 50 | 2778.55 | 138927.5 |
| 173 | 18 | Dressing and levelling of earhtwork to designed section, etc. complete:- b) Ordinary or hard soil. | 1000 Cft | 25 | 1018.6 | 25465 |
| 174 | 47 | Jungle clearance and removing within 100 ft. (30 m). b) Heavy | 1000 Sft | 55 | 812.05 | 44662.75 |
| 175 | 5 (f) + ( 1 of Ch-1) | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate): including lead up to 30 km ( 47976.70 + 2208 ) (f) Ratio 1:2: 4 | 100 Cft | 15.5 | 50184.7 | 777862.85 |
| 176 | (i) + (1 of CH-1) | (i) Ratio 1: 4: 8 ( 35568.70 + 2377.8 ) | 100 Cft | 30.75 | 37946.5 | 1166854.875 |
| 177 | 53 | Providing & fixing precast Edge Kerb Stone (4" to 6"thick) and 14" high of Compressive Strength of 3500 PSI laid in cement sand mortar (1:3) over pre-laid brick masonary for drain cum footpath etc complete in all respect. b) (ii) With painting | Per Rft | 1250 | 671.4 | 839250 |
| 178 | 43 | Providing and laying Tuff pavers, having 7000 PSI, crushing strength of approved manufacturer, over 2" to 3" sand cushion i/c grouting with sand in joints i/c finishing to require slope . complete in all respect. (50% Grey / 50% Coloured) b) 60-mm thick | Sft | 3500 | 216.1 | 756350 |
| 179 | 3 (a) | Providing and laying sub-base course of stone product of approved quality and grade, including placing, mixing, spreading and compaction of sub-base material to required depth, camber, grade to achieve 100% maximum modified AASHO dry density, including carriage of all material to site of work. ii) Crushed stone aggregate. | 100 Cft | 85 | 10389.75 | 883128.75 |
| 180 | 4(a) | Providing and laying base course of crushed stone aggregate of approved quality and grade, and supply and spreading of stone screening, including placing, mixing, spreading and compaction of base course material to required depth, camber and grade to achieve 100% maximum modified AASHO dry density, including carriage of all materials to site of work. | 100 Cft | 85 | 13859.1 | 1178023.5 |
| 181 | 6 | Providing and laying bituminous priming coat, using 10 lbs. kerosene oil and 10 lbs. binder per 100 Sft. or 0.5 Kg kerosene and 0.5 Kg binder per square metre. | 100Sft. | 150 | 2201.55 | 330232.5 |
| 182 | 10 | a) Providing and laying plant premixed bituminous carpet, including compaction and finishing to required camber, grade and density.(for 4" thickness) iv) 4.5% Bitumen Rate for 3" (3 x 7,159.70) =22557.15) | per inch thickness/100Sft | 150 | 21579.1 | 3236865 |
| 183 | 43 (2) | Earthwork excavation in open cutting for sewers and manholes as shown in drawings including shuttering and timbering, dressing to correct section and dimensions according to templates and levels, and removing surface water, in all types of soil except shingle, gravel and rock:- a) (iii) 0 ft. to 7.0 ft. (0 to 2.10 m) depth | 1000 Cft | 12.5 | 12907.8 | 161347.5 |
| 184 | 5 (f) + ( 1 of Ch-1) | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate): including lead up to 30 km ( 47976.70 + 2208 ) (f) Ratio 1:2:4 | 100 Cft | 10 | 50184.7 | 501847 |
| 185 | (i) + (1 of CH-1) | (i) Ratio 1: 4: 8 ( 35568.70 + 2377.8 ) | 100 Cft | 8 | 37946.5 | 303572 |
| 186 | 5 (i) | Pacca brick work ground floor:- i) Cement, sand mortar:- Ratio 1:4 | 100 Cft | 8.5 | 42181.95 | 358546.575 |
| 187 | 9 | Cement plaster 1:4 upto 20' (6.00 m) height:- c) ¾" (20 mm) thick | 100Sft | 150 | 6585.35 | 987802.5 |
| 188 | 3 (c) | Provi ding and l aying R.C.C. pipe sewers, moulded with cement concrete 4000 psi conforming to ASTM Specification C-76-20, specific class. Wall B, including carriage of pipe from factory to site of work, lowering in trenches to correct alignment and grade, jointing with rubber ring,cutting pipes where necessary, testing, etc. , complete. i) 310 mm (12") i/d | Rft | 275 | 1023.85 | 281558.75 |
| 189 | 5 | Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects. b) concrete Gully trap | Each | 25 | 7079.95 | 176998.75 |
| 190 | 14 | Providing and fixing 6" thick R.C.C. manhole cover with tee shaped C.I. frame of 22" I/d (frame weighing 37.324 Kg. or one maund as per Standard Drawing STD/PD No. 6, of 1977, complete in all respect. | Per Set | 21 | 24427.75 | 512982.75 |
| 191 | Non Schedule | Providing & Installation of water pressure boosting pumping system consisting of 2 nos of vertical multistage centrifugal pumps make (Grundfos/KSB/TACO) with requisite Grundfos/Siemens motor 3x400v, 2 pole, IP55, F class alarm with sluice valves, non return valves, suction and discharge headers with 2 nos. pressure tanks (300 liter each) bladder time imported, pressure gauge and pressure switches with motor control unit for system consisting of metalic box,magnetic control, ON/OFF switch, control fuse, CT control wire, electronic over current relay, auto manual selector switch, indication lamps etc. The pumps shall be capable of total discharge 90 IGPM, against 80 feet head, pumps shafts, mechanical seal, material of construction of pump, impeller, intermediate chamber, pump shaft in (Stainless Steel), electrical wiring from EDB to motor control unit of the system and motors complete in all respects including testing and commissioning as directed by the engineer-in-charge. | Each | 1 | 1550000 | 1550000 |
| 192 | Non Schedule | Supply, Installation, testing and commissioning of NFPA 20 compliant HMA Fire Fighting Pumping System switches fire installation on underground tank comprising of 1 no. main service Electrical driven vertical fire turbine pump coupled with motor (Grundfos/Siemens) of 50 HP 3 x 400v, 2 pole, IP 55, F classs and 1 no. Electrical driven backup vertical fire turbine pump coupled with motor Grundfos/Siemens) of 50 HP 3 x400v 2 pole IP 55 F class meeting the NFPA 20 Performance criteria. Electrical driven vertical fire turbine pump ( The both side fire pumps (Grundfor /KSB/Taco) having capacity 500 USGPM each at 7bar pressure meeting the NFPA 20 Performance criterial and shall not less than 150% of the rated capacity at a pressure of not less than 65% of the rated head at 2900 RPM ). The impellers of the fire pump must be bronze /SS and shaft in SS with one number electrical driven (Grundfos/HMA) Electrical multistage Jockey pump having discharge of 15 US GPM with 7 bar pressure having stainless steel. | Each | 1 | 5250000 | 5250000 |
| 193 | Non Schedule | Supply, Installation, testing and commissioning of NFPA 20 compliant Fire Fighting Pumping System on underground tank comprising of 1 no. main service Electrical driven Vertical fire turbine pump coupled with motor and 1 no. Diesel Engine driven backup vertical fire turbine pump coupled with motor. Make: KSB / DAB / NAFFCO / Equivalent | Each | 1 | 19364715 | 19364715 |
| 194 | i) 01 Nos Duty Electrical driven Vertical turbine fire pump, 750 USgpm @ 10 bar pressure. | |||||
| 195 | ii) 01 Nos Standby Diesel Engine driven backup Vertical turbine fire pump, 750 USgpm @ 10 bar pressure. | |||||
| 196 | iii) Electrical driven multistage jockey pump 25 USgpm @ 12 bar pressure. | |||||
| 197 | iv) Control panel: controller consists of all accessories like auto & manual switches, emergency switches, loss of phase, run period timer, short circuit protection etc. | |||||
| 198 | v) Delivery & suction side accessories include: Gate valve, pressure gauge, pressure switch and delivery manifold, common header, non retun valve (NRV), circulation relief valve & Strainer etc. | |||||
| 199 | Non Schedule | Providing, laying, jointing, Flushing & Hydrostatic testing MS (mild steel) ASTM seamless Schedule-40 pipelines with welded type fittings including tee, reducer, elbow, plug, socket, including protective coating consisting of two coats of bitumen and wrapping of bitumen dipped hessian cloth for pipes below ground and one coat of red oxide with two coats of enamel paint for pipe above ground, complete in all respect and as per specifications and drawings and as directed by the Engineer. Make: Baolai / Hebei Minhai / Equivalent. | ||||
| 200 | a) | Dia 150mm (6 inches) | Rft | 492 | 2500 | 1230000 |
| 201 | b) | Dia 100mm (4 inches) | Rft | 820 | 2000 | 1640000 |
| 202 | c) | Dia 75mm (3 inches) | Rft | 394 | 3705 | 1459770 |
| 203 | d) | Dia 65mm (2 1/2 inches) | Rft | 463 | 2955 | 1368165 |
| 204 | e) | Dia 50mm (2 inches) | Rft | 443 | 1873 | 829739 |
| 205 | f) | Dia 40mm (1 1/2 inches) | Rft | 164 | 1477 | 242228 |
| 206 | g) | Dia 32mm (1 1/4 inches) | Rft | 175 | 1208 | 211400 |
| 207 | h) | Dia 25mm (1 inches) | Rft | 165 | 895 | 147675 |
| 208 | Non Schedule | Providing & Installation & testing Automatic Air vent 3/4'' i/d as per BSS including the cost of 3/4'' ball valve to isolate the vent, complete in all respect as per specifications & drawings & as directed by the Engineer. TAP/Equivalent | Each | 2 | 15000 | 30000 |
| 209 | Non Schedule | Providing & Fixing & testing of external fire hydrant pillar type of specified size with delivery outlets with British instantaneous female coupling and blank caps, all connection to have individual ball valve manufactured by Haseen Habib or equivalent. | ||||
| 210 | a) | 4'' i/d barrel | Each | 6 | 40000 | 240000 |
| 211 | Non Schedule | Providing & Fixing External Fire Hose cabinet (Pak Made) made of steel sheet 24'' x 24'' x 9'' size, solid front, red painted with 100 Rft 2.5'' dia nylon rubber lined OSW hose 600 psi bursting pressure complete with male & female coupling & 2.5'' dia nozzle with each hose manufactured by Haseen Habib or equivalent. | Each | 6 | 45000 | 270000 |
| 212 | Non Schedule | Providing & Fixing of Internal Fire Hose Reel swinging type with 100 feet x 1'' i/d high pressure hose with nozzle 1'' inlet, 1" i/d Pressure Reducing Valve, 2.5" i/d Oblique Landing Valve , 2.5" i/d Hose Pipe, Jet Nozzle , Fire extinguishers CO2 5Kg & DCP 6Kg, Cabinet size 30'' W x 62'' H x 12'' D, powder coated, red finish, solid/glass front, complete in all respect. Manufactured By: Haseen Habib / Equivalent | Each | 23 | 341688 | 7858824 |
| 213 | Non Schedule | Providing and fixing multipurpose fire extinguishers Halotron – I model Halitron-2 complete with controlled discharged operating lever, pressure gauge, wall bracket & initial charged, manufactured by Haseen Habib or equivalent complete in all respect as per specification & drawings and as directed by the Engineer. | Each | 24 | 15000 | 360000 |
| 214 | Non Schedule | Providing & Installation of Gate Valves of the following sizes. Make : SCON / Mughal. | ||||
| 215 | a) | Dia 150mm (6 inches) | Each | 3 | 89741 | 269223 |
| 216 | b) | Dia 100mm (4 inches) | Each | 18 | 61542 | 1107756 |
| 217 | c) | Dia 75mm (3 inches) | Each | 2 | 44807 | 89614 |
| 218 | d) | Dia 65 mm (2 1/2 inches) | Each | 24 | 38059 | 913416 |
| 219 | e) | Dia 50 mm (2 inches) | Each | 20 | 30709 | 614180 |
| 220 | Non Schedule | Providing & Installation of Non Return Valves of the following sizes. Make : SCON / Mughal. | ||||
| 221 | a) | Dia 100mm (4 inches) | Each | 4 | 78471 | 313884 |
| 222 | b) | Dia 50mm (2 inches) | Each | 2 | 51220 | 102440 |
| 223 | Non Schedule | Supply & installation of Automatic Water Sprinkler, Brass Finish, 12.5 mm ( ½”) NPT (M) Coverage 13.4 M² (144 Sq ft) Temp 68-C, K-factor 5.6, quick response Pendent type with base plate. (Shield/Equivalent) | Each | 375 | 3475 | 1303125 |
| 224 | Non Schedule | Supply of Automatic Wall type Water Sprinkler, Brass Finish, 12.5 mm ( ½”) NPT (M) Temp 68-C, K-factor 5.6, quick response Pendent wall type. (Shield/Equivalent) | Each | 18 | 3654 | 65772 |
| 225 | Non Schedule | Providing & Installation of Flow switches. (Potter/Equivalent) | Each | 3 | 68310 | 204930 |
| 226 | Non Schedule | Supply of alarm check valve, vertical series complete with trim assembly, retarding chamber, pressure gauges and water motor bell, complete in all respects. Size: 150 mm | Each | 2 | 661586 | 1323172 |
| 227 | Non Schedule | Providing, fixing, testing and commissioning of PRV assembly consisting of 2 No. butterfly valve with temper switch, I No PRV, I No Flow switch, 2 No. pressure gauges complete in all respect. | Each | 2 | 578220 | 1156440 |
| 228 | Non Schedule | Providing and Fixing of Auto Fire Extinguisher 6 Kg for Electrical panel rooms on multiple floors. | Each | 18 | 109620 | 1973160 |
| 229 | Non Schedule | Providing and Installation of sprinkler Supervisory Panel (12- Zones), including temper switches, electrical wiring etc. (Global Fire/ Menvier OR Equivalent) | Each | 2 | 1813375 | 3626750 |
| 230 | Non Schedule | Providing and Installation of Reserved sprinkler Cabinet along with 50-Nos Sprinklers and wrench etc. | Each | 2 | 188715 | 377430 |
| 231 | Non Schedule | Providing & Fixing of Sprinkler test & drain line Valve | Each | 2 | 31050 | 62100 |
| 232 | Non Schedule | Providing & fixing of Fire brigade/Breeching inlet saimese connection (Twin). Flanged and with built in check valve. (Haseen Habib/Equivalent) | Each | 2 | 89973 | 179946 |
| 233 | Non Schedule | MCC for fire fighting system (Main Power Cable to MCC is not included). | Each | 2 | 583602 | 1167204 |
| 234 | Non Schedule | Standard Fire Protection Accessories 01 Ms Cabinet 03 Fire Suit. 06 Leather Gloves. 03 Hard Helmets. 03 Fire Blanket 03 Fire Service Mask. 03 Fireman Axe. | Each | 1 | 572680 | 572680 |
| 235 | ELECTRICAL INSTALLATION | |||||
| 236 | 3 (a) | Supply and erection of PVC pipe for wiri ngincluding inspection boxes, pull boxes, hooks, and repairing surace, etc., complete with all specials. | ||||
| 237 | ii) 80 mm i/d | Per Rft | 1250 | 299.65 | 374562.5 | |
| 238 | iii) 100 mm i/d | Per Rft | 650 | 377.65 | 245472.5 | |
| 239 | 10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 660/1000 volts grade cable, in to prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | ||||
| 240 | ix | 95 mm sq (37/0.072") | Per Rft | 500 | 1260.95 | 630475 |
| 241 | viii | 70 mm sq (19/0.083") | Per Rft | 375 | 917.85 | 344193.75 |
| 242 | vii | 50 mm sq (19/0.072") | Per Rft | 350 | 700.9 | 245315 |
| 243 | vi | 35 mm sq (19/0.064") | Per Rft | 1500 | 497.3 | 745950 |
| 244 | v | 25 mm sq (19/0.052") | Per Rft | 2000 | 358.5 | 717000 |
| 245 | iv | 16 mm sq (7/0.064") | Per Rft | 3500 | 234.3 | 820050 |
| 246 | iii | 10.00 mm sq (7/0.052") | Per Rft | 1000 | 155.7 | 155700 |
| 247 | 11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- c) PVC insulated, PVC sheathed 4 core, 660/1000 volt non armoured cable:- | ||||
| 248 | xvii) | 300 mm sq (61/0.099") | Per Rft | 300 | 16386.55 | 4915965 |
| 249 | xvi) | 240 mm sq (37/0.114") | Per Rft | 220 | 12679.45 | 2789479 |
| 250 | (xiii) | 120 mm2 (37/0.083") | Per Rft | 1200 | 6335.75 | 7602900 |
| 251 | (vi) | 50 mm2 (19/0.072") | Per Rft | 600 | 2562.85 | 1537710 |
| 252 | (vii) | 16 mm2 (7/0.064") | Per Rft | 1500 | 926.05 | 1389075 |
| 253 | (viii) | 25 mm (19/0.052") | Per Rft | 1500 | 1426.2 | 2139300 |
| 254 | (vi) | 10 mm (7/0.052") | Per Rft | 1000 | 605.85 | 605850 |
| 255 | 86 | Supplying ,Installation and commissioning of MCCB (Moulded Case Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as approved and directed by the Engineer Incharge. b) Four Pole | ||||
| 256 | (i) | 15-100 Amp(18KA) | Each | 12 | 23154.9 | 277858.8 |
| 257 | (iv) | 125-250 Amp(25 KA) | Each | 25 | 39467.4 | 986685 |
| 258 | 99 | Providing and fixing cable tray with straight flange fabricated with perforated G.I. Sheet of specified guage,size and depth duly supported on painted brackets of MS angle iron of 1-1/2"x1-1/2"x3/16" and MS patti of 1-1/2"x3/16" size @ 3 ft C/C, hangers i/c the cost of hardwares as approved and directed by the Engineer Incharge. (a) 14 SWG | ||||
| 259 | (i) | 12"x4" | Per Rft | 425 | 1303.25 | 553881.25 |
| 260 | (iii) | 16"x4" | Per Rft | 450 | 1467 | 660150 |
| 261 | (v) | 24"x4" | Per Rft | 500 | 1953.4 | 976700 |
| 262 | 102 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Exaust Fan i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. (a) Plastic body | ||||
| 263 | (ii) | 12 " dia | Each | 50 | 5685.5 | 284275 |
| 264 | (ii) | (b) Steel body | Each | 10 | 6641.75 | 66417.5 |
| 265 | 18" sweep | |||||
| 266 | 105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c thevcost of switches / sockets / dimmer made of Hi-Life / Bush / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge (a) One way Gange Switch | ||||
| 267 | SMALL (i) | 01 Gange | Each | 50 | 463.2 | 23160 |
| 268 | (ii) | 02 Gange | Each | 200 | 704.4 | 140880 |
| 269 | (iv) | Three pin Light Plug 10/13 Amp | Each | 250 | 754.45 | 188612.5 |
| 270 | (viii) | Three Pin Power Plug 15-32 Amp | Each | 150 | 924.55 | 138682.5 |
| 271 | LARGE (b) (i) | 04 Gange | Each | 350 | 981.25 | 343437.5 |
| 272 | (iii) | 06 Gange | Each | 195 | 1405.85 | 274140.75 |
| 273 | (i) | (c) Two way Gange Switch | ||||
| 274 | 01 Gange | Each | 56 | 499.9 | 27994.4 | |
| 275 | 104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. iii) 56" dia | Each | 332 | 10180.2 | 3379826.4 |
| 276 | 103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. i)18" Sweep dia | Each | 42 | 6861.15 | 288168.3 |
| 277 | SECTION -1 | |||||
| 278 | Points and Outlets wiring. | |||||
| 279 | Wiring with 450/750 V CU/PVC wires Low Smoke Zero Halogen Fire Retardant (LSZH) of approved make (including circuit wiring, solar/ups (where required) & insulated E.C.C) | |||||
| 280 | 1 | Circuit Wirring from DB to gang switch board with 3 x 7/0.74 mm (7/0.29") 2.5mm Low Smoke Zero Halogen Fire Retardant (LSZH) (R+B+G+Y+W) including UPS/Solar Circuit & Earth cable of pvc insulated single core cables in appropriate 25mm pvc conduit complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 198 | 5460 | 1081080 |
| 281 | 2 | Wiring of light or fan point or other from switch to the point with 3x1.5mm (3/0.029") Low Smoke Zero Halogen Fire Retardant (LSZH) pvc insualting single core cable in PVC 25mm pipes concealed in wall column and slab i/c acesseries like bend, tees etc complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 825 | 2730 | 2252250 |
| 282 | 3 | Point wiring from light point to point with 3x1.5mm (3/0.029") Low Smoke Zero Halogen Fire Retardant (LSZH) pvc insulated single core cables in appropriate 25mm pvc conduit recessed in wall and column as required complete in all respect and as approved by engineer incharge | Each | 528 | 1890 | 997920 |
| 283 | 4 | Wirring of 5 Amp 2/3 pin universal flush mounting switch socket unit away from switch board and wired with 3x2.5mm (7/0.029) Low Smoke Zero Halogen Fire Retardant (LSZH) single core cable from nearest circuit available in 25mm PVC concealed conduits or trunking including all conduit accessories as required complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 200 | 4410 | 882000 |
| 284 | 5 | The same as above item but wiring from one socket to another socket with 3x2.5 mm2 (7/0.029") Low Smoke Zero Halogen Fire Retardant (LSZH) single core cable complete in all respect and as approved by engineer incharge | Each | 225 | 4085 | 919125 |
| 285 | 6 | Wiring of 15/20 A 3-pin flush mounting switch socket unit (Power Plug) wired with 2x 6 mm2 Low Smoke Zero Halogen Fire Retardant (LSZH) 1-core and 1-core 2.5 mm2 Low Smoke Zero Halogen Fire Retardant (LSZH) (Earth) wires starting from Distribution Board in 25mm PVC pipe complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 388 | 7845 | 3043860 |
| 286 | 7 | The same as above item but wiring from one socket to another socket with 3x4 mm2 (7/0.029") Low Smoke Zero Halogen Fire Retardant (LSZH) single core cable complete in all respect and as approved by engineer incharge | Each | 356 | 4545 | 1618020 |
| 287 | SECTION - 2 | |||||
| 288 | LIGHT FIXTURES | |||||
| 289 | INCLUDING SUSPENSION/ FIXING MATERIAL | |||||
| 290 | Supply and Installation of LED light fittings of approved make. All the light fixture have the efficacy of 100 lumens/Watt & have 2 years of standard replacment warranty. The power factor of the light fitting should >0.9 & have <15% THD. The color shifting of the LED Source should not be greater than 5 SDCM for indoor light. The driver should be Meanwell or approved equivalent complete in all respects as per drawings, specifications and instructions of the Engineer In-charge.. | |||||
| 291 | 1 | Surface mounted Ceiling10-12 Watt LED down lighter. | Each | 280 | 2050 | 574000 |
| 292 | 2 | Surface mounted Ceiling15-18 Watt LED down lighter. | Each | 108 | 2850 | 307800 |
| 293 | 3 | surface mounted tornado type LED light fitting (4 feet long) with 36/40 watt ) LED Double Rod. | Each | 724 | 3750 | 2715000 |
| 294 | 4 | LED light fitting (4 feet long) with 18-20 watt ) LED. | Each | 60 | 2750 | 165000 |
| 295 | 5 | Decorative weatherproof Bulk Head light IP65 with 12Watt LED lamp. | Each | 45 | 2880 | 129600 |
| 296 | SECTION - 3 | |||||
| 297 | 1 | Main /Sub Main Distribution Boards | ||||
| 298 | INCOMING (Normal) Ground Floor, Basement | Each | 3 | 350000 | 1050000 | |
| 299 | 1-150 ATP MCCB (ICS 15 KA) | |||||
| 300 | 1-Digital voltmeter+volt selector switch | |||||
| 301 | 1-Digital ammeter+ammeter selector switch | |||||
| 302 | 3-C.T.'s ratio 150/5A | |||||
| 303 | 3-Phase indications lights+control fuses/MCB's (2A). | |||||
| 304 | OUTGOING | |||||
| 305 | 2-63 ATP MCCB (ICS 15 KA) | |||||
| 306 | 2-40 ATP MCCB (ICS 15 KA) | |||||
| 307 | 2 | Sub Main Distribution Boards (First Floor to Sixth Floor) | Each | 12 | 225000 | 2700000 |
| 308 | INCOMING | |||||
| 309 | 1-250 ATP MCCB (ICS 15 KA) | |||||
| 310 | 1-Digital voltmeter+volt selector switch | |||||
| 311 | 1-Digital ammeter+ammeter selector switch | |||||
| 312 | 3-C.T.'s ratio 200/5A | |||||
| 313 | 3-Phase indications lights+control fuses/MCB's (2A). | |||||
| 314 | OUTGOING | |||||
| 315 | i). | 4-63 ATP MCCB (ICS 15 KA) | ||||
| 316 | ii). | 1-40 ATP MCCB (ICS 15 KA) | ||||
| 317 | 3 | Distribution Board Normal | Each | 12 | 175000 | 2100000 |
| 318 | Incoming | |||||
| 319 | 1x63 A TP MCCB (15 - KA) | |||||
| 320 | Outgoing | |||||
| 321 | 33 Nos 10 Amp SP (MCB) (6-KA) | |||||
| 322 | 18 Nos 16 Amp SP (MCB) (6-KA) | |||||
| 323 | 1 Nos 25 Amp TP (MCB) (6-KA) | |||||
| 324 | 4 | Distribution Board (FF1-FF4 & 2F1-2F4) | Each | 12 | 125000 | 1500000 |
| 325 | i) | Incoming | ||||
| 326 | 1x100 A TP MCCB (15 - KA) | |||||
| 327 | Outgoing | |||||
| 328 | 33 Nos 10 Amp SP (MCB) (6-KA) | |||||
| 329 | 18 Nos 16 Amp SP (MCB) (6-KA) | |||||
| 330 | 5 | Distribution Board (Miscellaneous ) | Each | 4 | 85000 | 340000 |
| 331 | i). | Incoming | ||||
| 332 | 1x80 A TP MCCB (15 - KA) | |||||
| 333 | Outgoing | |||||
| 334 | i). | 13 Nos 6/10/15/20 Amp SP (MCB) (6-KA), 1Nos 63 ATP MCCB 15KA | ||||
| 335 | SECTION - 4 | |||||
| 336 | Earthing and Lightning Protection | |||||
| 337 | 1 | Supply and installation of Earthing comprising copper plate 24" x 24" x 1/4" placed at 20 feet depth not less than 10 feet away from the building foundations, connecting to the distribution board/generator body by double run of Earthing Lead including excavation and back filling with coal, lime & salt mixture in 1:1:1 ratio around the plate, and fixing 1/2" dia G.I. water and feed pipe to full depth of excavation, including cost of brick masonry chamber of 12" x 12" clear size sinside duly plastered inside, M.S. hinged cover of 16 SWG thick M.S. sheet and 1" x 1" x 1/8" angle iron frames, duly enamel painted, complete as per specification and as directed. The chamber is to be constructed on firm/original ground to avoid settlement complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 4 | 60000 | 240000 |
| 338 | 2 (a). | Supply, fixing of 1"x1/8" copper strip on walls, parapet of the building including Copper Saddles, nails and all other necessary fixing material complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Rft | 1550 | 685 | 1061750 |
| 339 | (b). | Supply, installation and commissioning of test point 250 mm x 75 mm x 6 mm complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 6 | 6800 | 40800 |
| 340 | (c). | Supply, installation and commissioning of lightning protection air terminal, 20 mm dia and 450 mm long copper rod (Air Terminal) complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 10 | 8500 | 85000 |
| 341 | (d). | Supply, installation and commissioning of 20mm dia 3 meter long copper rod as earth electrode for lightning protection system including the cost of concrete pit and all necessary material complete with 300mm x 300 x 300mm inspection chamber with CI cover,complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 6 | 10200 | 61200 |
| 342 | 11 (b) | Supply and erection of PVC insulated, PVC sheathed copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- b) Three core, 600/1000 volt cable:- vi) 7/1.63 mm (7/0.064") | Per Rft | 1200 | 706.25 | 847500 |
| 343 | 11 (c ) | c) PVC insulated, PVC sheathed 4 core, 660/1000 volt non armoured cable:- | ||||
| 344 | xvii) | 300 mm sq (61/0.099") | Per Rft | 300 | 16386.55 | 4915965 |
| 345 | xvi) | 240 mm sq (37/0.114") | Per Rft | 220 | 12679.45 | 2789479 |
| 346 | (x) | 120 mm2 (37/0.083") | Per Rft | 1200 | 6335.75 | 7602900 |
| 347 | 108 | Supply, insatllation, commissioning and testing of oil cooled type, Step down Power Transformer pole mounted of specified rating,11/0.415 kV, i/c the cost of lifting hooks, thermometers, LT & HT bushing 5-steps, tap changer, imported double float buchholz relay, 2 earthing terminals, roller wheels, connecting terminals for cables M.S box on transformer in order to cover complete L.T side, all necessary materials required for connections on H.T & L.T side, rated voltage 11000/415/240 V specified impedance as specified by WAPDA/IEC system earth: Delta / Star, neutral solidly earthed, i/c Wapda testing charges,complete in all changer, imported double float buchholz relay, 2 earthing terminals, roller wheels, connecting terminals for cables M.S box on transformer in order respects made of PEL, Siemens, Transfopower, Elmetec or as approved and directed by the Engineer Incharge | ||||
| 348 | a) | (ix) 630 KVA | Each | 1 | 4304717 | 4304717 |
| 349 | b) | (ii) 1000 KVA | Each | 1 | 5262217 | 5262217 |
| 350 | Supply and installation of double arm MS lighting pole 10M high with 2 Nos. "PIERLITE" Roadspan 250W high pressure sodium lamp road lighting fixture complete with all accessories including lamp, ballast, capacitor, ignitor, junction box and wiring from junction box to fixture complete in all respect. | Each | 20 | 160000 | 3200000 | |
| 351 | AS above but single arm 8M high pole with 1 No. "PHILIPS" Avenue SGX186 250W HPS lighting fixture. | Each | 25 | 135000 | 3375000 | |
| 352 | Supply and installation of Gate Light with 70 W HPS Lamp. | Each | 8 | 7500 | 60000 | |
| 353 | Power Distribution System (Sub-Station) | |||||
| 354 | Supply, Installation & Commissioning of sheet metal clad totally enclosed free standing, front excess LT-SWITCH BOARD frames fabricated from 14-SWG sheet steel derusted phosphated & with electrostatic paint of approved color Size (2100(700+4x800)800)mm, and suitable for system voltage 400/230,50 Hz., 3 phase & Neutral bus bars (Rated as per incoming breaker) of 99.99% electrolytic copper conductor, rated to a minimum short circuit of 55 KA for 3 seconds. Earthing link, Internal wiring. The switch board shall be equipped with following air circuit breakers/moulded case circuit breakers rated at 50 ºC of specified breaking capacity. Shop drawings shall be submitted by the contractor for approval before the manufacture of all distribution equipment. All breakers, instrumentations and other materials shall be make SIEMENS or approved equivalent as listed in Annexure “A”.complete in all respects as per drawings, specifications and instructions of the Engineer In- | |||||
| 355 | Main LT Panel Having 1 Incomig From Wapda Having Following Incoming & Out Goings | Each | 1 | 16983220 | 16983220 | |
| 356 | incoming | |||||
| 357 | 1 No. ACB 2000A TP 65KA (NW20H1) | |||||
| 358 | 1 No. Motor Mechanism | |||||
| 359 | 1 No. UVT | |||||
| 360 | 1 No. Shunt Trip | |||||
| 361 | 1 No. Closing Coil | |||||
| 362 | 3 No. Volt Meter (0~500) (Digital) | |||||
| 363 | 3 No. AMP Meter (2000/5A) (Digital) | |||||
| 364 | 3 No. Control Fuse 2A with Base | |||||
| 365 | 1 No.Energy Analyzer | |||||
| 366 | 3 No. C.T 2000/5A | |||||
| 367 | 4 No. HRC Fuse With Base | |||||
| 368 | 1 No. Surge Protective Device FP 100KA | |||||
| 369 | 1 No. Timer | |||||
| 370 | 2 No. Auxiliary Contactor | |||||
| 371 | 1 No. H-O-A S/Switch TP | |||||
| 372 | 2 No. Push Button (On/Off) | |||||
| 373 | 2 No. Indication Light (On/Off) | |||||
| 374 | 3 No. Indication Light (R/Y/B) | |||||
| 375 | 3 No. Control MCB 6A SP 6KA (R/Y/B) | |||||
| 376 | 5 No. Limit Switch | |||||
| 377 | 10 No. Louver With Mash | |||||
| 378 | 5 No. Exhaust Fan 6''/8" | |||||
| 379 | 3 No. Thermostate Switch | |||||
| 380 | 5 No. Control MCB 6A SP 6KA | |||||
| 381 | 20 No. Control Terminal Block 2.5mm | |||||
| 382 | Outgoing Wapda | |||||
| 383 | 20 No. MCCB 250A TP 25KA (EZC250N) | |||||
| 384 | 12 No. MCCB 400A TP 36KA (EZC400N) | |||||
| 385 | 8 No. MCCB 630A TP 50KA (NSX630N) | |||||
| 386 | 1 No. Bus Bar & Insulator | |||||
| 387 | Supply and installation of Lv Panels/ PFI Plant (500 KVAR ) fabricated from 14- SWG Size (2100(2x700)800)mm Comprising the following complete in all respect as per drawings, specifications and instrucation of the engineer incharge. | Each | 1 | 3485255 | 3485255 | |
| 388 | 1 No. C.T 2000/5A | |||||
| 389 | 8 No. Capacitor 50KVAR | |||||
| 390 | 4 No. Capacitor 25KVAR | |||||
| 391 | 8 No. Magnetic Contactor TP (LC1 - D95) | |||||
| 392 | 4 No. Magnetic Contactor TP (LC1 - D65A) | |||||
| 393 | 24 No. HRC Fuse 100A With Base | |||||
| 394 | 12 No. HRC Fuse 63A With Base | |||||
| 395 | 1 No. PFI Relay 12 Stage | |||||
| 396 | 6 No. Control Relay | |||||
| 397 | 1 No. H-O-A S/Switch | |||||
| 398 | 25 No. Indication Light (On/Off) | |||||
| 399 | 24 No. Push Button (On/Off) | |||||
| 400 | 3 No. Control MCB 6A SP 6KA | |||||
| 401 | 2 No. Limit Switch | |||||
| 402 | 4 No. Louver With Mash | |||||
| 403 | 2 No. Exhaust Fan 6''/8" | |||||
| 404 | 1 No. Thermostate Switch | |||||
| 405 | 2 No. Control MCB 6A SP 6KA | |||||
| 406 | 8 No. Control Terminal Block 2.5mm | |||||
| 407 | 1 No. Bus Bar & Insulator | |||||
| 408 | Supply and installation of M.v Panel (2 No. Incoming and 4 No. outgoings), Make of Siemens or approved equlaint Comprising the following complete in all respect and instrucation of the engineer incharge. | Each | 1 | 54035288 | 54035288 | |
| 409 | HT Panel (Protection Panel) Supply and installation of HT (Protection Panel) 11 KVA 4 way Switch/Panel Indoor type,one Incoming and 3,Out goings. | Each | 2 | 3500000 | 7000000 | |
| 410 | Supply & Installation of Cat-6A U/UTP Cable, Solid Copper, • Conductor Diameter: AWG 23 (0.57±0.005 mm) • Insulation Diameter: PE Ø 1.03±0.03 mm mm • Number of Pairs: 4 pairs • Conductor Type: Solid Bare Copper • Sheath material: LSZH Standards: Cables Cabling System Standard Fire Rating IEC 61156-5 ed. 2 • ISO/IEC11801 ed.2 • PVC: IEC 60332-1 LSZH: IEC 60332-1• ANSI/TIA 568-C.2 (i-Connect/UK, Panduit USA or Equivalent) | Rft | 2850 | 115 | 327750 | |
| 411 | Supply & Installation of Single/Dual Port Face Plate without Shuttered, UK Style 86x86mm with Top Label Holder, Color Signal White with 1-PVC Back Box Mandatory Features: • Single Port Wihout Shuttered Face Plate with Label holder with white label strip and transparent hinged cover• Keystone Fixing • UK standard single gang faceplate with 86 x 86 mm dimensions • Color Signal White• Compatible with all keystone jacks (Shielded/unshielded, Cat. 5E/6/6A, with/without shutters) • Two mounting screws included • Back Box, PVC/Steel 16SWG (i-Connect/UK, Panduit USA or Equivalent) | Nos | 180 | 725 | 130500 | |
| 412 | Supply & Installation of U/UTP Cat-6A Toolles Shuttered I/O, Mandatory Features: • Toolless Assembly • u/UTP I/O Shielded, 10G Supported • Shuttered I/O • Keystone Fixing Standards: SO/IEC 11801 Ed.2.2• DIN EN 50173-1• TIA EIA-568-C.2• IEC 60603-7-51 ((i-Connect/UK, Panduit USA or Equivalent) | Nos | 90 | 1535 | 138150 | |
| 413 | Supply & Installation of 24 Port Patch Panel with U/UTP Cat-6A Toolless Shuttered I/Os, Fully Loaded, Mandatory Features: • 24 Port Patch Panel with Top Label Holder • Patch Panel Color Black • Toolless Assembly • U/UTP I/O, Shielded, 10G Supported • Shuttered I/O • Keystone Fixing Standards: SO/IEC 11801 Ed.2.2 • DIN EN 50173-1• TIA EIA-568-C.2• IEC 60603-7-51 (i-Connect/UK, Panduit USA or Equivalent) | Nos | 10 | 38500 | 385000 | |
| 414 | Supply & Installation of Cable Manager Mandatory Features: • Horizontal and Vertical Hoops • Cage Nut Set included • Standard EIA 19" rack and cabinet mount • Plastic, 1U • Available in black colour (i-Connect/UK, Panduit USA or Equivalent) | Nos | 12 | 4390 | 52680 | |
| 415 | Supply & Installation of U/UTP Cat-6A RJ45 to RJ45 Patch Cord, PVC, 1-Meter 10G Supported (i-Connect/UK, Panduit USA or Equivalent) | Nos | 28 | 1245 | 34860 | |
| 416 | Supply & Installation of U/UTP Cat-6A RJ45 to RJ45 Patch Cord, PVC, 3-Meter, 10G Supported (i-Connect/UK, Panduit USA or Equivalent) | Nos | 28 | 1680 | 47040 | |
| 417 | Supply & Installation of Optical Fiber Patch Cord, Single Mode, SC/LC and SC/SC Duplex, 3/5-Meter (i-Connect/UK, Panduit USA or Equivalent) | Nos | 5 | 3650 | 18250 | |
| 418 | Supply & Installation 25 Pair Cable 0.5mm (i-Connect/UK, Panduit USA or Equivalent) | Rft | 235 | 335 | 78725 | |
| 419 | Supply and Installation of PVC Pipe 1 Inch With Socket and Bend (Adamjee or equivalent) | Rft | 6635 | 30 | 199050 | |
| 420 | Supply & Installation PoE 24-Port Switch 24x 10/100/1000 Ethernet PoE+ ports and 370W PoE budget, 4x 10G SFP+ uplinks Switching capacity: 125 Gbps , Forwarding performance: 92 Mpps Memory 500 MB and Flash 500 MB The equipment must support up to 30K MAC address tables , 4K ARP entries and 4K IPv4 Routes. Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 1 | 438500 | 438500 | |
| 421 | Supply & Installation PoE 48-Port Switch 48x 10/100/1000 Ethernet PoE+ ports and 740W PoE budget, 4x 10G SFP+ uplinks Switching capacity: 120 Gbps , Forwarding performance: 170Mpps Memory 2GB and Flash 1GB The equipment must support up to 60K MAC address tables , 16K ARP entries and 16K IPv4 Routes Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 1 | 410000 | 410000 | |
| 422 | Supply & Installation Optical Transceiver,SFP+,10G,Single-mode Module(1310nm,10km,LC) (Huawei/Cisco or Eqequivalent) | Nos | 1 | 105000 | 105000 | |
| 423 | Supply & Installation IP Office SMB Model Consisting of IP office IP500 VERSION 2A control unit with SD card, power cord and rackmount kit inclusive of 3 years avaya support (Avaya-Alcatel Equivalent) | Nos | 1 | 1550000 | 1550000 | |
| 424 | Supply & Installation IP OFFICE MEDIA CARD VOICE (VCM) CODING MODULE 64 V2 (Avaya-Alcatel Equivalent) | Nos | 1 | 98000 | 98000 | |
| 425 | Supply & Installation IP OFFICE R11 ESSENTIAL EDITION LIC:DS (Avaya-Alcatel Equivalent) | Nos | 1 | 87500 | 87500 | |
| 426 | Supply & Installation IP OFFICE R10+ AVAYA IP ENDPOINT 1 LIC:CU (Avaya-Alcatel Equivalent) | Nos | 70 | 6700 | 469000 | |
| 427 | Supply & Installation J159 IP Phone Executive (Avaya-Alcatel Equivalent) | Nos | 6 | 55600 | 333600 | |
| 428 | Supply & Installation J139 IP Phone (Avaya-Alcatel Equivalent) | Nos | 8 | 45000 | 360000 | |
| 429 | Supply & Installation Image Sensor: 4 MPX CMOS sensor 1/3” SmartSens; Min. Illumination: 0.005 lx (0 lx, IR on); Digital Slow Shutter (DSS): up to 1/3 s; Wide Dynamic Range (WDR): WDR double scan, 120dB; Digital Noise Reduction (DNR): 2D, 3D; Defog Function (F-DNR): Defog (F-DNR); HLC; Lens Type: fixed focal, f=2.8 mm/F1.6; Switching Type: mechanical IR cut filter; Frame Rate: 30 fps for 2592 x 1520, 60 fps for 1920 x 1080 (Full HD) and lower resolutions; Multistreaming Mode: 3 streams; Video/Audio Compression: H.264, H.264+, H.264 Smart, H.265, H.265+, H.265 Smart, MJPEG/G.711; Privacy Zones: 4; motion detection; Video Content Analysis (VCA): tamper, abandoned object, object disappearance, line cross, zone entrance, zone exit, object counting, face detection, pedestrian detection, cross counting, Scene Change, Video Blurred, Video Color Cast, objects distinguishing, people counting, vehicle detection, vehicle counting; IR LED: IR LED, range up to 30 m; Audio Input/Output: wej. audio audio; Memory Card Slot: microSD - capacity up to 128GB; Dimensions (mm): 95 (Ф) x 83 (H); Degree of Protection: IP 67; Enclosure: vandalproof IK10 impact rating aluminium, white; Power Supply: PoE, 12 VDC; Operating Temperature: -30°C ~ 60°C (Bosh/Novus/Honeywell or equivalent) | Nos | 8 | 78000 | 624000 | |
| 430 | Supply & Installation Image Sensor: 4 MPX CMOS sensor 1/3” SmartSens; Min. Illumination: 0.005 lx (0 lx, IR on); Digital Slow Shutter (DSS): up to 1/3 s; Wide Dynamic Range (WDR): WDR double scan, 120dB; Digital Noise Reduction (DNR): 2D, 3D; Defog Function (F-DNR): Defog (F-DNR); HLC; Lens Type: fixed focal, f=2.8 mm/F1.6; Switching Type: mechanical IR cut filter; Frame Rate: 30 fps for 2592 x 1520, 60 fps for 1920 x 1080 (Full HD) and lower resolutions; Multistreaming Mode: 3 streams; Video/Audio Compression: H.264, H.264+, H.264 Smart, H.265, H.265+, H.265 Smart, MJPEG/G.711; Privacy Zones: 4; motion detection; Video Content Analysis (VCA): tamper, abandoned object, object disappearance, line cross, zone entrance, zone exit, object counting, face detection, pedestrian detection, cross counting, Scene Change, Video Blurred, Video Color Cast, objects distinguishing, people counting, vehicle detection, vehicle counting; IR LED: IR LED, range up to 50 m; Audio Input/Output: wej. audio; Memory Card Slot: microSD - capacity up to 128GB; Degree of Protection: IP 67; Enclosure: aluminium, white, fully cable managed wall mount bracket in-set included , IK10 impact rating; Power Supply: PoE, 12 VDC; Operating Temperature: -30°C ~ 60°C (Bosh/Novus/Honeywell or equivalent) | Nos | 8 | 85000 | 680000 | |
| 431 | Supply & Installation Image Sensor: 4 MPX CMOS sensor 1/2.5” ON Semiconductor; Min. Illumination: from 0.002 lx (0 lx, IR on); Digital Slow Shutter (DSS): up to 1 s; Wide Dynamic Range (WDR): WDR double scan, 120dB; Digital Noise Reduction (DNR): 2D, 3D; Defog Function (F-DNR): Defog (F-DNR); HLC; Optical Zoom: 25x; Lens Type: motorized, auto-iris function, f=4.8 ~ 120 mm/F1.65 ~ F3.8; Switching Type: mechanical IR cut filter; Frame Rate: 30 fps for each resolution; Multistreaming Mode: 3 streams; Video/Audio Compression: H.264, H.265, MJPEG/-; Preset Commands: 360 including 20 special (function) presets; Tours: 8 (up to 16 presets per tour); Patterns: 4 (max. 360 commands or 180 s for each pattern); motion detection; Video Content Analysis (VCA): Auto Tracking linked to Video Content Analysis (VCA) functions, tamper, line cross, zone entrance, zone exit, cross counting, Scene Change, Video Blurred, Video Color Cast, zone entrance detection and object tracking, objects distinguishing, comparing faces; IR LED: IR LED, range up to 130 m (depends on current optical zoom value); Memory Card Slot: microSD - capacity up to 256GB; Degree of Protection: IP 66; Enclosure: aluminium, white, , in set: outdoor housing (integrated with the camera), wall mount bracket; Power Supply: PoE+, 12 VDC; Operating Temperature: -30°C ~ 55°C; Built-in Heater/Fan: yes/yes; (Bosh/Novus/Honeywell or equivalent) | Nos | 1 | 275000 | 275000 | |
| 432 | Supply & Installation UNIVERSAL KEYBOARD FOR MANAGING CCTV APPLICATIONS FROM PC USB keyboard for managing CCTV applications, with joystick and jog shuttle (Bosh/Novus/Honeywell or equivalent) | Nos | 1 | 210000 | 210000 | |
| 433 | Supply & Installation 32CH NETWORK VIDEO RECORDER (with 2 HDD supported) Video and audio channels: 32 Supported protocols: ONVIF, RTSP Recording speed up to 960 fps at 4000 x 3000 Recorded stream size: 192 Mb/s in total from all cameras Internal HDDs mount: 2 Monitor outputs: 2 (HDMI (4K UltraHD), VGA) RACK mount Face recognition (Bosh/Novus/Honeywell or equivalent) | Nos | 1 | 475000 | 475000 | |
| 434 | Supply & Installation HD 16 TB | Nos | 1 | 98000 | 98000 | |
| 435 | Supply & Installation LED 4K 45" (Samsung/LG or equivalent) | Nos | 1 | 195000 | 195000 | |
| 436 | Public Adress System | |||||
| 437 | Public Adress System: Providing, fixing, testing and commissioning of the following Public adress System equipment make LDA Audio Tech/ Passo/ Honey Well or approved equivalent complete in all respects as per drawings, specifications and instructions of the Engineer In-charge.- | |||||
| 438 | Mixing Amplifier with Matrix , Storage type: | Each | 1 | 1450000 | 1450000 | |
| 439 | 8 amplifier sound box with 5 analog audio inputs and two amplification configurations, dual amplification outputs fro A+B wiring. 8 pre-amp outputs for external PA amplifiers connection, triple Ethernet port , audio Matrix 7x8, LED indicators according to standard, Touch screen with at least 4GB internal Memory with RJ45 connection including all fittings & Accesriescomplete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | |||||
| 440 | Mixing Amplifier Standard: 350 W mixing Amplifier including all fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 1 | 195000 | 195000 | |
| 441 | MULTI-ZONE PAGING MICROPHONE . 8 zone buttons, all zones Call button, Recall function, and LED indicators for selected-zone, occupied-zone and floor taken, as well as system indicators or Latch mode configuration. The buttons can be configured from the configuration software, equalization or gain adjustment, recording or playback of pre-recorded messages and transparent cover for zone's names indication etc. including all fittings & Accesriescomplete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 2 | 105575 | 211150 | |
| 442 | Call Station complete with Chime Microphone, DVD Player, Equipment Rack and accessories including all fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 2 | 62500 | 125000 | |
| 443 | MULTISOURCE TWO CHANNELS PLAYER DVD/USB/SD AND FM/AM RADIO TUNNER Integrated multisource player with DVD player, USB and SD interface, Independent DVD/USB/SD and FM/AM lines outputs, mix audio RCA output with two line outputs with independent volume control. Support CD, DVD,USB, videos and JPEG. RMVB 720P etc. including all fittings & Accesries complete in all respect or instruction of Engineer Incharge. | Each | 2 | 72400 | 144800 | |
| 444 | CEILING SPEAKERS 6" Ceiling metal speaker for 70/100V lines with fire protection low loss transformer 6w, 3w 100 V Line 3W, 1.5W Frequency response 100-20000Hz+/- 10db, sensitivity 92db etc. i/c all fittings & accesseries complete in all respect or instruction of Engineer Incharge. | Each | 66 | 8200 | 541200 | |
| 445 | ANTIVANDAL CYLINDER SOUND PROJECTION, fixing of 5" metal speaker for 70/100 V line i/c all fittings & accesseries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 4 | 12500 | 50000 | |
| 446 | Testing and commissiong and maintenaince under warrenty from the date of commessioning including spare parts complete in all respects as per instructions of the Engineer In-charge.. | Job | 2 | 125000 | 250000 | |
| 447 | Fire Retendent Cable: Providing, laying and connecting of 2 core 1.5mm2 copper conductor fire resistant cable complete in all respects as per drawings, specifications and instructions of the Engineer In-charge.. | Rft | 6250 | 88 | 550000 | |
| 448 | Providing, laying PVC conduit in roof slab, walls, ceiling etc. 1" (25mm) dia complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Rft | 2385 | 26 | 62010 | |
| 449 | Providing, laying PVC conduit in roof slab, walls, ceiling etc. 3/4" (20mm) dia complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Rft | 1148 | 22 | 25256 | |
| 450 | Fire Alarm System: Providing, fixing, testing and commissioning of the following Fire Alarm equipment make Velex, Gent, Menvire, Photain, Simplex, Ziton,Honey Well or approved equivalent complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | |||||
| 451 | Adressable Fire Alarm control panel, Compact 4 loop panal with 1 loop card and battries with, 1 loop capacity maximum 200, with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 8 | 533250 | 4266000 | |
| 452 | 10 Zone repeater Fire Alarm control panel with power supply, with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 4 | 240975 | 963900 | |
| 453 | Addressable optical smoke detector: Optical smoke detector for general fire detection application with common base plate, diodes nominal voltage 9-28v dc Operating temp.= -10ºc to+50ºc with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 150 | 7425 | 1113750 | |
| 454 | Addressable optical Heat detector: Optical smoke detector for general fire detection application with common base plate, diodes nominal voltage 9-28v dc Operating temp.= -10ºc to+50ºc with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 45 | 7500 | 337500 | |
| 455 | Addressable manual call points: Manual call stations are manufactured From ABS with plastic covered push glass, Nominal voltage 24 v dc , Operating temp.= 0ºc to+50ºc with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 80 | 9075 | 726000 | |
| 456 | Addressable Flasher Wall sounder: with both audible and visual alaram signals (flash), bulit in volume level control and short circuit isolater, with all necessary fittings & Accesries complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Each | 15 | 12350 | 185250 | |
| 457 | Fire Retendent Cable: Providing, laying and connecting approved make of 2 core 1.5mm2 copper conductor fire retendent cable (draka, perle UK or approved Equivalent )complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Rft | 17375 | 155 | 2693125 | |
| 458 | Providing and laying of PVC conduit in roof slab, walls, ceiling etc. 3/4" (20mm) dia complete in all respects as per drawings, specifications and instructions of the Engineer In-charge. | Rft | 18375 | 62 | 1139250 | |
| 459 | Supply & Installation, testing & commissioning of Cat-6A U/UTP Cable, Solid Copper, • Conductor Diameter: AWG 23 (0.57±0.005 mm) • Insulation Diameter: PE Ø 1.03±0.03 mm mm • Number of Pairs: 4 pairs • Conductor Type: Solid Bare Copper • Sheath material: LSZH Standards: Cables Cabling System Standard Fire Rating IEC 61156-5 ed. 2 • ISO/IEC11801 ed.2 • PVC: IEC 60332-1 LSZH: IEC 60332-1• ANSI/TIA 568-C.2 (i-Connect/UK, Panduit USA or Equivalent) | Rft | 8500 | 112 | 952000 | |
| 460 | Supply & Installation, testing & commissioning of Single/Dual Port Face Plate without Shuttered, UK Style 86x86mm with Top Label Holder, Color Signal White with 1-PVC Back Box Mandatory Features: • Single Port Wihout Shuttered Face Plate with Label holder with white label strip and transparent hinged cover• Keystone Fixing • UK standard single gang faceplate with 86 x 86 mm dimensions • Color Signal White• Compatible with all keystone jacks (Shielded/unshielded, Cat. 5E/6/6A, with/without shutters) • Two mounting screws included • Back Box, PVC/Steel 16SWG (i-Connect/UK, Panduit USA or Equivalent) | Nos | 250 | 725 | 181250 | |
| 461 | Supply & Installation, testing & commissioning of U/UTP Cat-6A Toolles Shuttered I/O, Mandatory Features: • Toolless Assembly • u/UTP I/O Shielded, 10G Supported • Shuttered I/O • Keystone Fixing Standards: SO/IEC 11801 Ed.2.2• DIN EN 50173-1• TIA EIA-568-C.2• IEC 60603-7-51 ((i-Connect/UK, Panduit USA or Equivalent) | Nos | 250 | 1535 | 383750 | |
| 462 | Supply & Installation, testing & commissioning of 24 Port Patch Panel with U/UTP Cat-6A Toolless Shuttered I/Os, Fully Loaded, Mandatory Features: • 24 Port Patch Panel with Top Label Holder • Patch Panel Color Black • Toolless Assembly • U/UTP I/O, Shielded, 10G Supported • Shuttered I/O • Keystone Fixing Standards: SO/IEC 11801 Ed.2.2 • DIN EN 50173-1• TIA EIA-568-C.2• IEC 60603-7-51 (i-Connect/UK, Panduit USA or Equivalent) | Nos | 13 | 46750 | 607750 | |
| 463 | Supply & Installation, testing & commissioning of Cable Manager Mandatory Features: • Horizontal and Vertical Hoops • Cage Nut Set included • Standard EIA 19" rack and cabinet mount • Plastic, 1U • Available in black colour (i-Connect/UK, Panduit USA or Equivalent) | Nos | 14 | 4375 | 61250 | |
| 464 | Supply & Installation, testing & commissioning of U/UTP Cat-6A RJ45 to RJ45 Patch Cord, PVC, 1-Meter 10G Supported (i-Connect/UK, Panduit USA or Equivalent) | Nos | 250 | 1245 | 311250 | |
| 465 | Supply & Installation, testing & commissioning of U/UTP Cat-6A RJ45 to RJ45 Patch Cord, PVC, 3-Meter, 10G Supported (i-Connect/UK, Panduit USA or Equivalent) | Nos | 250 | 1675 | 418750 | |
| 466 | Supply & Installation, testing & commissioning of 12 Core Optical Fiber Cable, Single Mode, PE Sheet, Black (i-Connect/UK, Panduit USA or Equivalent) | Rft | 1500 | 152 | 228000 | |
| 467 | Supply & Installation, testing & commissioning of 12 Port Rack Mounted ODF with Pigtails, Adopters, Sleeves, Splicing Trays, Fully Loaded, Single Mode (i-Connect/UK, Panduit USA or Equivalent) | Nos | 10 | 43500 | 435000 | |
| 468 | Supply & Installation, testing & commissioning of 24 Port Rack Mounted ODF with Pigtails, Adopters, Sleeves, Splicing Trays, Fully Loaded, Single Mode (i-Connect/UK, Panduit USA or Equivalent) | Nos | 2 | 125000 | 250000 | |
| 469 | Supply & Installation, testing & commissioning of 48 Port Rack Mounted ODF with Pigtails, Adopters, Sleeves, Splicing Trays, Fully Loaded, Single Mode (i-Connect/UK, Panduit USA) | Nos | 2 | 138000 | 276000 | |
| 470 | Supply & Installation, testing & commissioning ofOptical Fiber Patch Cord, Single Mode, SC/LC and SC/SC Duplex, 3/5-Meter (i-Connect/UK, Panduit USA or Equivalent) | Nos | 50 | 3650 | 182500 | |
| 471 | Supply & Installation, testing & commissioning of 12U Wall Mounted Cabinet W600*D600 with side door locks, 1-PDU Toughened glass front door with symmetrical strip-type vented hole border Standard:Comply with ANSI/EIA, RS-310-D, IEC297-2, DIN41494;PART1, DIN41494;PART7, GB/T3047.2-92, ETSI standard. Material: Spcc cold Rolled Steel Thickness :Mounting profiles:1.5mm; Side panels, back panel :0.8mm;others 1.2mm Surface finish: Degreasing, Vitrification, power coated; Degree of protection: IP20. Loading capacity: Static loading: 60KG (HP,i-Connect/UK or Equivalent) | Nos | 1 | 51000 | 51000 | |
| 472 | Supply & Installation, testing & commissioning of 15U Wall Mounted Cabinet W600*D600 with side door locks, 1-PDU Toughened glass front door with symmetrical strip-type vented hole border Standard:Comply with ANSI/EIA. RS-310-D, IEC297-2, DIN41494;PART1, DIN41494;PART7, GB/T3047.2-92. ETSI standard. Material: Spcc cold Rolled Steel Thickness :Mounting profiles:1.5mm; Side panels, back panel :0.8mm;others 1.2mm Surface finish: Degreasing, Vitrification, power coated; Degree of protection: IP20. Loading capacity:Static loading: 60KG (HP, i-Connect/UK or Equivalent) | Nos | 1 | 65500 | 65500 | |
| 473 | Supply & Installation, testing & commissioning of42U Network Cabinet 600*1000 Perforated front door & Double Secction rear door Elegant Lock with 2-Fix, 1-Sliding Trays, 4-Fans, 4-Wheels, 1-PDU Standard:Comply with ANSI/EIA, RS-310-D.IEC297-2, DIN41494;PART1, DIN41494;PART7, GB/T3047.2-92、ETSI standard. Front & Rear Door: *Toughened glass front door with symmetrical strip-type vented hole border * Steel Rear Door without Vented hole * front & Rear Doors are Free Solder Reinforcement Structure Elegant and Sturdy *Front & Rear Door with Elegant Lock Material: Mounting Profile & Mounting Angle, Fingerprint resistant aluminum zinc plate,SPCC cold rolled steel, Thickness, Mounting profile 2.0mm, Mounting angle 1.5mm, others 1.2mm, Surface finish: Degreasing, Vitrification, power coated; Degree of protection:IP20. (HP, i-Connect/UK or Equivalent) | Nos | 2 | 283000 | 566000 | |
| 474 | Supply & Installation, testing & commissioning of 42U 800x1000 Server Floor Standing Rack, Front Perforated, 4-Fans, 2-Fix, 1-Sliding Trays, Back Double Door, • Flat vented front single door with handle lock. • Double flat vented rear doors with handle lock. • Flat door border and arc door edge treatment. • Removable side doors to enable easy access. • Top and bottom wire path holes. • Max load capacity 1000kg. • Made of SPCC quality cold rolled steel material. • Mounting rails 2.0mm and mounting angle 1.2 - 1.5mm. • IP20 standard protections. • Degreasing, acid pickling, Parkerizing surface finishing. Compliance: Complies with ANSI/EIA RS-310-D, IEC297-2, DIN41491; PART1, DIN41494; PART7, ETSI (HP, i-Connect/UK or Equivalent) | Nos | 2 | 348500 | 697000 | |
| 475 | Supply & Installation, testing & commissioning of 3" x 6" GI Cable Tray Profrated With Cover 18SWG With Pin Anchor Sleve 10mm,threading Rod 10mm,Angle Iron 1.5" x1" for Cable Tray Supports and Nut Bolts(Local) | Rft | 550 | 445 | 244750 | |
| 476 | Supply & Installation, testing & commissioning of 3" x 9" GI Cable Tray Profrated With Cover 18SWG With Pin Anchor Sleve 10mm,threading Rod 10mm,Angle Iron 1.5" x1" for Cable Tray Supports and Nut Bolts (Local) | Rft | 576 | 623 | 358848 | |
| 477 | Supply & Installation, testing & commissioning of 3" x 12" GI Cable Tray Profrated With Cover 18SWG With Pin Anchor Sleve 10mm,threading Rod 10mm,Angle Iron 1.5" x1" for Cable Tray Supports and Nut Bolts (Local) | Rft | 615 | 800 | 492000 | |
| 478 | Supply & Installation, testing & commissioning of PVC Pipe 1 Inch With Socket and Bend (Adamjee or equivalent) | Rft | 1750 | 29 | 50750 | |
| 479 | Supply & Installation, testing & commissioning of PoE 24-Port Switch 24x 10/100/1000 Ethernet PoE+ ports and 370W PoE budget, 4x 10G SFP+ uplinks Switching capacity: 125 Gbps , Forwarding performance: 92 Mpps Memory 500 MB and Flash 500 MB The equipment must support up to 30K MAC address tables , 4K ARP entries and 4K IPv4 Routes. Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 2 | 378000 | 756000 | |
| 480 | Supply & Installation, testing & commissioning of 24-Port Switch 24x 10/100/1000 Ethernet ports, 4x 10G SFP+ uplinks Switching capacity: 125 Gbps , Forwarding performance: 92 Mpps Memory 500 MB and Flash 500 MB The equipment must support up to 30K MAC address tables , 4K ARP entries and 4K IPv4 Routes. Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 1 | 365000 | 365000 | |
| 481 | Supply & Installation, testing & commissioning of48-Port Switch 48x 10/100/1000 Ethernet ports, 4x 10G SFP+ uplinks Switching capacity: 170 Gbps , Forwarding performance: 130 Mpps Memory 500 MB and Flash 500 MB The equipment must support up to 30K MAC address tables , 4K ARP entries and 4K IPv4 Routes. Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 2 | 235000 | 470000 | |
| 482 | Supply & Installation, testing & commissioning of Core Switch 28 x 25 Gig SFP28, 4 x 100 Gig QSFP28(25GE SFP28 interfaces support 10GE, 100GE QSFP28 interfaces support 40GE) Switching capacity: 2.1Tbps Memory 4GB and Flash 2GB The equipment must support up to 300K MAC address tables , 100K ARP entries and 250K IPv4 Routes. Support for Telnet, SSHv2, IPv4 and IPv6, RIP, OSPFv2, v3, DHCP Server, STP, RSTP, MSTP or equivalent Brand should be minimum in Visionaries position in Wired and Wireless LAN Infrastructure Gartner report (Huawei/Cisco or Eqequivalent) | Nos | 1 | 1950000 | 1950000 | |
| 483 | Supply & Installation, testing & commissioning of Access Point Dual Band 2.4 GHz and 5 GHz bands, at a rate of up to 570Mbps at 2.4 GHz(2x2), 1Gbps at 5GHz (2x2), and 1.70Gbps for the device Interfaces: 1 x GE electrical 1 x USB,BLE 5.0 Available transmit power settings (2.4 & 5 GHz): 2.4GHz: 25dBm (combined power) 5GHz: 25dBm (combined power) Support number of users (512/Radio) Supported Features: Uplink/downlink OFDMA, MU-MIMO technology, BSS coloring, Target wake time,Bluetooth (Huawei/Cisco or Eqequivalent) | Nos | 13 | 197395 | 2566135 | |
| 484 | Supply, Installation, testing, and commissioning of imported brand new Simplex Passenger Cum Cargo Elevator, Machine Room Less (MRL Type), Single Entrance Door, heavy duty fully complied and certified by EN 81-20, EN 81-50 and EN 81-70 Standards of minimum features including but not limited to VVVF high efficiency motor, complete inside stainless steel finish,indoor type for ambient condition of 0°C - 40 °C, capacity of 1000 kg, Cabin Size1100 ×2100 ×2300 mm (W×D×H) speed 1.5~ 1.75m/s, 10 /10 openings, approx. total travel height 38 meter . entrance 900 × 2100 mm (W×H). Lift shall minimum includes car, hoisting machinery, counter-weight, supports, brackets, automatic controls, embedded parts, access ladder, separator screen & trap door, electric overload, shaft lightening, intercom system, gong, emergency operation for cabin/door, emergency rescue device (ups/battery) safety devices & Manual emergency operation lever, all essential spare parts for use for two (02) year of defect liability period complete in all respects as per specification & Drawings and according to EN 81 standard compliance.All taxes/duties shall be included.(Country/origin of manufacturing USA, EUROPE, JAPAN) | Each | 3 | 17500000 | 52500000 | |
| 485 | Supply and installation, testing & commissioning of 500 KVA DG Set of approved make F.G. Wilson, Cummins (uk), Perkins (uk) or approved equivelant 400/230 Volt, 3 Phase Auto Start Skid Mounted Set complete with ATS / AMF panel, weather proof out door acoustic canopy (low noise sielencer) built in fuel tank sufficient. continuous operator as per specification, drawing and instruction of the Engineer Incharge. | Each | 2 | 37500000 | 75000000 | |
| 486 | SUPPLY OF WATER COOLED ELECTRIC OPERATED SCREW CHILLER WITH BACnet ENABLED BMS NETWORK CARD COMPLETE AS SPECIFIED & SCHEDULED. | |||||
| 487 | CH 1-1 | Each | 1 | 38000000 | 38000000 | |
| 488 | CH 1-2 | Each | 1 | 38000000 | 38000000 | |
| 489 | SUPPLY OF FRP INDUCED DRAFT CROSS FLOW VERTICAL DISCHARGE TYPE COOLING TOWERS COMPLETE AS SPECIFIED & SCHEDULED. | |||||
| 490 | CT 1-1 | Each | 1 | 11857500 | 11857500 | |
| 491 | SUPPLY OF FORCED DRAFT HORIZONTAL TYPE AUTO IGNITION HOT WATER GENERATOR COMPLETE AS SPECIFIED & SCHEDULED. | |||||
| 492 | HWG-1 | Each | 1 | 3383100 | 3383100 | |
| 493 | HWG-2 | Each | 1 | 3383100 | 3383100 | |
| 494 | SUPPLY OF AIR HANDLING UNITS COMPLETE AS SPECIFIED & SCHEDULED. | |||||
| 495 | AHU / 1 | Each | 1 | 5042500 | 5042500 | |
| 496 | AHU / 2 | Each | 1 | 4118500 | 4118500 | |
| 497 | AHU /3 | Each | 1 | 4712500 | 4712500 | |
| 498 | AHU / 4 | Each | 1 | 4118500 | 4118500 | |
| 499 | AHU / 5 | Each | 1 | 4712500 | 4712500 | |
| 500 | AHU / 6 | Each | 1 | 4712500 | 4712500 | |
| 501 | AHU / 7 | Each | 1 | 4712500 | 4712500 | |
| 502 | AHU /8 | Each | 1 | 3285250 | 3285250 | |
| 503 | AHU /9 | Each | 1 | 3970000 | 3970000 | |
| 504 | AHU /10 | Each | 1 | 3970000 | 3970000 | |
| 505 | SUPPLY OF CEILING CONCEILED TYPE DUCTED FAN COIL UNITS BUILT-IN 2-WAY CONTROL VALVE COMPLETE WITH WIRED REMOTE CONTROLLER AS SPECIFIED & SCHEDULED. | |||||
| 506 | FCU-1 | Each | 10 | 313600 | 3136000 | |
| 507 | FCU-2 | Each | 10 | 344000 | 3440000 | |
| 508 | FCU-3 | Each | 25 | 360000 | 9000000 | |
| 509 | FCU-4 | Each | 10 | 555520 | 5555200 | |
| 510 | FCU-5 | Each | 8 | 797600 | 6380800 | |
| 511 | FCU-6 | Each | 8 | 974400 | 7795200 | |
| 512 | FCU-7 | Each | 8 | 670400 | 5363200 | |
| 513 | FCU-8 | Each | 1 | 1563200 | 1563200 | |
| 514 | SUPPLY OF BMS TEMPERATURE & AUTOCONTROL WITH CONTROL VALVES (2-WAY), ACTUATORS, SENSORS AND CONTROLERS FOR AHUs SHOWN ON DRAWING. | Each | 2 | 1125000 | 2250000 | |
| 515 | SUPPLY OF BMS TEMPERATURE & AUTOCONTROL WITH SENSORS AND CONTROLERS FOR DSAC's SHOWN ON DRAWING. | Each | 2 | 750000 | 1500000 | |
| 516 | SUPPLY OF BMS TEMPERATURE & AUTOCONTROL FOR HVAC PLANT ROOM AND COOLING TOWER, COMPLETE WITH MOTORIZED VALVES, ACTUATORS, SENSORS, CONTROLER, SOFTWARE (LIFETIME LICENCED), COMPUTER & PRINTER INCLUDING SUPERVISORY CONTROL, AS SHOWN ON DRAWING. | Each | 1 | 4375000 | 4375000 | |
| 517 | SUPPLY OF BMS CONTROL FOR PARKING VENTILATION FANS AT BASEMENTS WITH CARBON MONOXIDE (CO) SENSORS AS SHOWN ON DRAWING | LOT | 1 | 3125000 | 3125000 | |
| 518 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF WATER COOLED ELECTRIC OPERATED SCREW CHILLER WITH #T ENABLED BMS NETWORK CARD INCLUDING UNLOADING, LIFTING AND PLACING AT FOUNDATIONS AS SHOWN ON DRAWINGS AND SPECIFIED COMPLETE IN ALL RESPECT | |||||
| 519 | CH 1-1 | NO | 1 | 272000 | 272000 | |
| 520 | CH 1-2 | NO | 1 | 272000 | 272000 | |
| 521 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF FRP INDUCED DRAFT CROSS FLOW VERTICAL DISCHARGE TYPE COOLING TOWERS INCLUDING UNLOADING, LIFTING AND PLACING AT FOUNDATIONS AS SHOWN ON DRAWINGS AND SPECIFIED COMPLETE IN ALL RESPECT | |||||
| 522 | CT 1-1 | NO | 1 | 487500 | 487500 | |
| 523 | INSTALLATION, TESTING AND COMMISSIONING OF FORCED DRAFT HORIZONTAL TYPE AUTO IGNITION HOT WATER GENERATOR INCLUDING UNLOADING, LIFTINGN AND PLACING AS SHOWN ON DRAWINGS AND SPECIFIED IN SPECIFICATION COMPLETE IN ALL RESPECT | |||||
| 524 | HWG-1 | NO | 1 | 203700 | 203700 | |
| 525 | HWG-1 | NO | 1 | 203700 | 203700 | |
| 526 | INSTALLATION, TESTING AND COMMISSIONING OF GAS PIPELINE CONNECTION FOR HOT WATER GENERATOR COMPLETE IN ALL RESPECT | LOT | 1 | 2000000 | 2000000 | |
| 527 | INSTALLATION, TESTING AND COMMISSIONING OF AIR HANDLING UNITS INCLUDING UNLOADING, LIFTING AND PLACING AT FOUNDATIONS AS SHOWN ON DRAWINGS, SCHEDULED AND SPECIFICATIONS, COMPLETE IN ALL RESPECT | |||||
| 528 | AHU / 1 | NO | 1 | 76200 | 76200 | |
| 529 | AHU / 2 | NO | 1 | 76200 | 76200 | |
| 530 | AHU / 3 | NO | 1 | 76200 | 76200 | |
| 531 | AHU / 4 | NO | 1 | 76200 | 76200 | |
| 532 | AHU / 5 | NO | 1 | 76200 | 76200 | |
| 533 | AHU / 6 | NO | 1 | 76200 | 76200 | |
| 534 | AHU / 7 | NO | 1 | 76200 | 76200 | |
| 535 | AHU / 8 | NO | 1 | 76200 | 76200 | |
| 536 | AHU / 9 | NO | 1 | 76200 | 76200 | |
| 537 | AHU / 10 | NO | 1 | 76200 | 76200 | |
| 538 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CHILLED WATER CENTRIFUGAL END SUCTION PUMPS INCLUDING LIFTING AND PLACING AT FOUNDATIONS AS SHOWN ON DRAWINGS & SPECIFIED. | |||||
| 539 | CHP-1-1 | NO | 1 | 1592200 | 1592200 | |
| 540 | CHP-1-2 | NO | 1 | 1592200 | 1592200 | |
| 541 | CHP-1-2 (Stand By) | NO | 1 | 1592200 | 1592200 | |
| 542 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CONDENSER WATER CENTRIFUGAL END SUCTION PUMPS INCLUDING LIFTING AND PLACING AT FOUNDATIONS AS SHOWN ON DRAWINGS & SPECIFIED. | |||||
| 543 | CWP-1-1 | NO | 1 | 1566875 | 1566875 | |
| 544 | CWP-1-2 | NO | 1 | 1566875 | 1566875 | |
| 545 | CWP-1-2 (Stand By) | NO | 1 | 1566875 | 1566875 | |
| 546 | SUPPLY & INSTALLATION OF AIR SEPARATOR COMPLETE WITH ACCESSORIES AS SPECIFIED & SCHEDULED. | |||||
| 547 | AS-1 | NO | 1 | 533400 | 533400 | |
| 548 | SUPPLY & INSTALLATION OF CLOSED CYLINDRICAL DIAPHRAGM TYPE EXPANSSION TANK COMPLETE WITH ACCESSORIES AS SPECIFIED & SCHEDULED. | |||||
| 549 | ET-1 | NO | 1 | 622500 | 622500 | |
| 550 | SUPPLY & INTALLTION OF DIESEL STORAGE DAY TANK FOR HOT WATER GENERATOR, CONSTRUCTED WIH 3MM M.S SHEET. DAY TANK SHALL BE PROVIDED WITH FLOAT VALVE, INLET & OUTLET VALVES, DRAIN COCK AND GAGE GLASS FOR LEVEL MONITORING, COMPLETE WITH ACCESSORIES AS SPECIFIED AND SCHEDULED. | |||||
| 551 | DT-1 | NO | 1 | 1536500 | 1536500 | |
| 552 | SUPPLY INSTALLATION, TESTING AND COMMISSIONING OFCEILING CONCEILED TYPE DUCTED FAN COIL UNITS BUILT-IN 2-WAY CONTROL VALVE COMPLETE WITH WIRED REMOTE CONTROLLER, INCLUDING UNLOADING, LIFTING AND FIXING AS SHOWN ON DRAWINGS & SPECIFIED | |||||
| 553 | FCU-1 | NO | 10 | 13950 | 139500 | |
| 554 | FCU-2 | NO | 10 | 13950 | 139500 | |
| 555 | FCU-3 | NO | 25 | 13950 | 348750 | |
| 556 | FCU-4 | NO | 10 | 13950 | 139500 | |
| 557 | FCU-5 | NO | 8 | 13950 | 111600 | |
| 558 | FCU-6 | NO | 8 | 13950 | 111600 | |
| 559 | FCU-7 | NO | 8 | 13950 | 111600 | |
| 560 | FCU-8 | NO | 1 | 13950 | 13950 | |
| 561 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DSACs WITH THERMOSTATE CONTROL KIT, INCLUDING UNLOADING, LIFTING AND PLACING AS SHOWN ON DRAWINGS & SPECIFIED. COMPLETE IN ALL RESPECT. | |||||
| 562 | DSAC-1 / CU-1 | NO | 1 | 5712000 | 5712000 | |
| 563 | DSAC-1 / CU-1 | NO | 1 | 5712000 | 5712000 | |
| 564 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DUCT MOUNT ELECTRICAL HEATERS COMPLETE WITH HIGH TEMPERATURE LIMIT THERMOSTATE FOR SAFTY, INCLUDING UNLOADING, LIFTING AND FIXING AS SHOWN ON DRAWING & SPECIFIED | |||||
| 565 | EDH-1 | NO | 1 | 199750 | 199750 | |
| 566 | EDH-2 | NO | 10 | 199750 | 1997500 | |
| 567 | SUPPLY, INSTALLATION, TESTNG AND COMMISSIONING OF DECORATIVE WALL MOUNTED TYPE COOL & HEAT SPLIT AIR CONDITIONERS WITH WIRELESS REMOTE CONTROL, INCLUDING UNLOADNG, LIFTING & FIXING AS SHOWN ON DRAWING & SPECIFIED. | |||||
| 568 | SAC-1 | NO | 15 | 550000 | 8250000 | |
| 569 | SAC-2 | NO | 15 | 650000 | 9750000 | |
| 570 | SUPPLY AND INSTALLATION OF COPPER PIPES WITH 3/4" CLOSE CELL FOAM INSULATION AND CONTROL WIRE FOR DSACs, INSULATION SHALL PROTECTED WITH PVC TAPE, COMPLETE IN ALL RESPECT. | |||||
| 571 | DIA 1.0 INCH | RFT | 375 | 3643 | 1366125 | |
| 572 | DIA 5/8 INCH | RFT | 375 | 1976 | 741000 | |
| 573 | SUPPLY AND INSTALLATION OF MANUFACTURER RECOMMEND SIZES COPPER PIPES WITH 3/4" CLOSE CELL FOAM INSULATION AND CONTROL WIRE FOR SPLIT ACs. INSULATION SHALL PROTECTED WITH PVC TAPE. COMPLETE IN ALL RESPECT. | |||||
| 574 | SAC-1 | RFT | 330 | 1573 | 519090 | |
| 575 | SAC-2 | RFT | 190 | 1969 | 374110 | |
| 576 | SUPPLY & INSTALLATION OF TRUNKING OF G.I SHEET (US GAUGE-22) WITH REMOVEABLE TOP COVER FOR EXPOSED COPPER PIPES AS SHOWN ON THE DRAWINGS | |||||
| 577 | 18" X 3" | RFT | 100 | 2426 | 242600 | |
| 578 | 12" X 3" | RFT | 20 | 2170 | 43400 | |
| 579 | SUPPLY & INSTALLATION OF FRESH & EXHAUST FANS AS SPECIFIED, SCHEDULED.& SHOWN ON DRAWINGS | |||||
| 580 | EF-1 | NO | 2 | 537030 | 1074060 | |
| 581 | EF-2 | NO | 2 | 642600 | 1285200 | |
| 582 | EF-3 | NO | 1 | 596700 | 596700 | |
| 583 | EF-4 | NO | 1 | 202300 | 202300 | |
| 584 | EF-5 | NO | 4 | 95200 | 380800 | |
| 585 | EF-6 | NO | 3 | 78540 | 235620 | |
| 586 | EF-7 | NO | 1 | 4001800 | 4001800 | |
| 587 | EF-8 | NO | 1 | 634100 | 634100 | |
| 588 | SF-1 | NO | 1 | 1028500 | 1028500 | |
| 589 | PF-1 | NO | 1 | 547400 | 547400 | |
| 590 | SUPPLY & INSTALLATION OF CHEMICAL FEEDER AND CHEMICALS AS SPECIFIED FOR CHILLED WATER SYSTEM WITH SUFFCIENT CHEMICALS FOR FEEDING FOR 1 YEAR OPERATION, TESTING AND COMMISSIONING. BASED ON 10 HRS OPERATION PER DAY | Lot | 1 | 632500 | 632500 | |
| 591 | SUPPLY & INSTALLATION OF CHEMICAL FEEDER, DOZING PUMP AND CHEMICALS AS SPECIFIED FOR CONDENSER WATER SYSTEM WITH SUFFCIENT CHEMICALS FOR FEEDING FOR 1 YEAR OPERATION, TESTING AND COMMISSIONING. BASED ON 10 HRS OPERATION PER DAY | Lot | 1 | 632500 | 632500 | |
| 592 | SUPPLY AND INSTALLATION OF DUCTING & SHEET METAL WORK COMPLETE WITH HANGERS, BRACINGS, SPLITTER DAMPERS ETC. | |||||
| 593 | US GAUGE 26 | SFT | 2150 | 443 | 952450 | |
| 594 | US GAUGE 24 | SFT | 4750 | 541 | 2569750 | |
| 595 | US GAUGE 22 | SFT | 5500 | 627 | 3448500 | |
| 596 | US GAUGE 20 | SFT | 1865 | 684 | 1275660 | |
| 597 | US GAUGE 18 | SFT | 1475 | 696 | 1026600 | |
| 598 | SUPPLY & INSTALLATION OF 1.0" THICK FIBER GLASS BALNKET INSULATION OF DENSITY 1.0 LBS/Ft3, HAVING FACTORY APPLIED FRK FACING PROTECTED WITH 8OZ CANVAS CLOTH COMPLETE WITH ADHESIVES, SEALERS AND PROTECTIONS, COMPLETE IN ALL RESPECT. | SFT | 9500 | 293 | 2783500 | |
| 599 | SUPPLY AND & INSTALLATION OF 12 GAUGE THICK MS SHEET FLUE DUCT WITH 3" THICK ROCK WOOL INSULATION AND 26GAUGE G.I SHEET CLADDING FOR HOT WATER GENERATOR's EXHAUST OF SIZE DIA 12". | RFT | 125 | 7475 | 934375 | |
| 600 | SUPPLY & INSTALATION OF AIR DEVICES AS SPECIFIED AND SCHEDULED | |||||
| 601 | SRAD | (SUPPLY ROUND AIR DIFFUSER) DIA 12" | NO | 15 | 4928 | 73920 |
| 602 | SD | (SWIRL DIFFUSER) DIA 16" | NO | 175 | 4928 | 862400 |
| 603 | SAD | (SUPPLY AIR DIFFUSER) | SFT | 148 | 4691 | 694268 |
| 604 | RAD | (RETURN AIR DIFFUSER) | SFT | 135 | 4691 | 633285 |
| 605 | EAD | (EXHAUST AIR DIFFUSER) | SFT | 21 | 4928 | 103488 |
| 606 | EAG | (EXHAUST AIR GRILLE) | SFT | 90 | 4928 | 443520 |
| 607 | SAG | (SUPPLY AIR GRILLE) | SFT | 45 | 4806 | 216270 |
| 608 | RAG | (RETURN AIR GRILLE) | SFT | 10 | 4806 | 48060 |
| 609 | RAL | (RETURN AIR LINEAR GRILL) 3" X 2 SLOTS X 3/4" | RFT | 190 | 1890 | 359100 |
| 610 | L | (Fresh/ Exhaust) Louver | SFT | 165 | 4455 | 735075 |
| 611 | SUPPLY & INSTALLATION OF 18 GAUGE GI SHEET DAMPERS AS SPECIFIED. COMPLETE IN ALL RESPECT. | |||||
| 612 | VCD (VOLUME CONTROL DAMPER) | SFT | 125 | 5003 | 625375 | |
| 613 | FD (FIRE DAMPER) UL | SFT | 95 | 5665 | 538175 | |
| 614 | SUPPLY & INSTALLATION OF GRAVITY SHUTTER TYPE DUCT MOUNTED NON RETURN DAMPERS AS SPECIFIED. COMPLETE IN ALL RESPECT | |||||
| 615 | NRD (NON RETURN DAMPER) | SFT | 50 | 5003 | 250150 | |
| 616 | SUPPLY AND INSTALLATION OF 2" THICK WASH ABLE ALUMINUM MESH FILTERS OTHER THAN INSTALLED IN AHUS FABRICATED WITH MIN. 12 MESH LAYERS | SFT | 35 | 3553 | 124355 | |
| 617 | SUPPLY AND INSTALLATION OF GLASS FIBER SOUND LINER OF DENSITY 1.5 LBS/Ft3 COMPLETE WITH ADHESIVES & SEALERS | SFT | 1500 | 290 | 435000 | |
| 618 | FLEXIBLE DUCT CONNECTORS 3" WIDE FACTORY FABRICATED WITH COATD WOVEN FABRIC AND GI COLLARS BOTH BY MEANS OF DOUBLE LOCK SEAM ON EACH SIDE | RFT | 1225 | 508 | 622300 | |
| 619 | SUPPLY & INSTALLATION OF BLACK STEEL SEAMLESS SCHEDULED 40 PIPING & FITTINGS EXCLUDING VALVES AND STRAINERS INCLUDING HANGERS ANCHOR BOLTS FOR CHILLED WATER CIRCULATION. | |||||
| 620 | DIA 0.50 INCH | RFT | 350 | 504 | 176400 | |
| 621 | DIA 0.75 INCH | RFT | 1350 | 605 | 816750 | |
| 622 | DIA 1.00 INCH | RFT | 550 | 814 | 447700 | |
| 623 | DIA 1.25 INCH | RFT | 500 | 1008 | 504000 | |
| 624 | DIA 1.50 INCH | RFT | 475 | 1225 | 581875 | |
| 625 | DIA 2.00 INCH | RFT | 475 | 1535 | 729125 | |
| 626 | DIA 2.50 INCH | RFT | 200 | 2441 | 488200 | |
| 627 | DIA 3.00 INCH | RFT | 65 | 3139 | 204035 | |
| 628 | DIA 4.00 INCH | RFT | 290 | 4410 | 1278900 | |
| 629 | DIA 5.00 INCH | RFT | 210 | 6107 | 1282470 | |
| 630 | DIA 6.00 INCH | RFT | 125 | 7711 | 963875 | |
| 631 | DIA 8.00 INCH | RFT | 125 | 12710 | 1588750 | |
| 632 | DIA 10.00 INCH | RFT | 225 | 12788 | 2877300 | |
| 633 | DIA 12.00 INCH | RFT | 90 | 13222 | 1189980 | |
| 634 | SUPPLY & INSTALLTION OF PVC PIPING AND FITTINGS WITH 1/2" THICK JUMBOLON FOAM INSULATION AS SCHEDULED, EXCLUDING VALVES AND STRAINERS, INCLUDING HANGERS, ANCHOR BOLTS FOR CONDENSATE DRAIN WATER. | |||||
| 635 | DIA 0.75 INCH | RFT | 1125 | 250 | 281250 | |
| 636 | DIA 1.00 INCH | RFT | 650 | 297 | 193050 | |
| 637 | DIA 1.25 INCH | RFT | 345 | 385 | 132825 | |
| 638 | DIA 2.00 INCH (CT DRAIN) | RFT | 100 | 736 | 73600 | |
| 639 | SUPPLY & INSTALLATION OF ELASOMERIC/EPDM CLOSED CELL FM APPROVED FOAM TYPE INSULATION OF DENSITY 45-65 Kg/m3 AND THERMAL CONDUCTIVITY 0.035 W/M AT 24 DEG C OF CLASS-0 RATING, PROTECTED WITH FIRE RETARDENT TYPE HIGH DENSITY CLOSELY WOVEN SHINY FIBERGLASS CLOTH AS SPECIFIED BY MANUFACTURED COMPLETE WITH ADHESIVES AND SEALERS AS SPECIFIED & SCHEDULED FOR CHILLED WATER PIPING & FITTING INCLUDING VALVES, STRAINERS ETC. | |||||
| 640 | DIA 0.50 INCH | RFT | 165 | 457 | 75405 | |
| 641 | DIA 0.75 INCH | RFT | 1020 | 508 | 518160 | |
| 642 | DIA 1.00 INCH | RFT | 650 | 558 | 362700 | |
| 643 | DIA 1.25 INCH | RFT | 565 | 616 | 348040 | |
| 644 | DIA 1.50 INCH | RFT | 375 | 725 | 271875 | |
| 645 | DIA 2.00 INCH | RFT | 375 | 798 | 299250 | |
| 646 | DIA 2.50 INCH | RFT | 145 | 1088 | 157760 | |
| 647 | DIA 3.00 INCH | RFT | 68 | 1160 | 78880 | |
| 648 | DIA 4.00 INCH | RFT | 375 | 1508 | 565500 | |
| 649 | DIA 5.00 INCH | RFT | 265 | 1479 | 391935 | |
| 650 | DIA 6.00 INCH | RFT | 100 | 1668 | 166800 | |
| 651 | DIA 8.00 INCH | RFT | 45 | 2211 | 99495 | |
| 652 | SUPPLY & INSTALLATION OF 26-GAUGE G.I SHEET CLADDING OVER INSULATED CHILLED WATER PIPES & VALVES IN PLANT ROOM | SFT | 1250 | 405 | 506250 | |
| 653 | SUPPLY AND INSTALLATION OF GATE VALVES. | |||||
| 654 | DIA 0.50 INCH | NO | 20 | 4050 | 81000 | |
| 655 | DIA 0.75 INCH | NO | 65 | 5333 | 346645 | |
| 656 | DIA 1.00 INCH | NO | 15 | 7054 | 105810 | |
| 657 | DIA 1.25 INCH | NO | 8 | 10463 | 83704 | |
| 658 | DIA 2.00 INCH | NO | 10 | 23355 | 233550 | |
| 659 | SUPPLY AND INSTALLATION OF BUTTERFLY VALVES. | |||||
| 660 | DIA 2.50 INCH | NO | 8 | 25684 | 205472 | |
| 661 | DIA 3.00 INCH | NO | 2 | 28961 | 57922 | |
| 662 | DIA 4.00 INCH | NO | 1 | 36720 | 36720 | |
| 663 | DIA 5.00 INCH | NO | 5 | 50355 | 251775 | |
| 664 | DIA 6.00 INCH | NO | 6 | 57375 | 344250 | |
| 665 | DIA 8.00 INCH | NO | 1 | 60075 | 60075 | |
| 666 | DIA 10.00 INCH | NO | 2 | 66488 | 132976 | |
| 667 | DIA 12.00 INCH | NO | 1 | 76579 | 76579 | |
| 668 | SUPPLY AND INSTALLATION OF BALANCING VALVES. | |||||
| 669 | DIA 0.50 INCH | NO | 7 | 3861 | 27027 | |
| 670 | DIA 0.75 INCH | NO | 20 | 5667 | 113340 | |
| 671 | DIA 1.00 INCH | NO | 5 | 8026 | 40130 | |
| 672 | DIA 1.25 INCH | NO | 2 | 11340 | 22680 | |
| 673 | DIA 2.00 INCH | NO | 3 | 32805 | 98415 | |
| 674 | DIA 2.50 INCH | NO | 4 | 42525 | 170100 | |
| 675 | DIA 3.00 INCH | NO | 2 | 52650 | 105300 | |
| 676 | DIA 4.00 INCH | NO | 4 | 69188 | 276752 | |
| 677 | DIA 5.00 INCH | NO | 1 | 90315 | 90315 | |
| 678 | DIA 6.00 INCH | NO | 1 | 129128 | 129128 | |
| 679 | DIA 8.00 INCH | NO | 3 | 229500 | 688500 | |
| 680 | SUPPLY AND INSTALLATION OF STRAINERS. | |||||
| 681 | DIA 0.50 INCH | NO | 8 | 3173 | 25384 | |
| 682 | DIA 0.75 INCH | NO | 20 | 4566 | 91320 | |
| 683 | DIA 1.00 INCH | NO | 5 | 6413 | 32065 | |
| 684 | DIA 1.25 INCH | NO | 2 | 9477 | 18954 | |
| 685 | DIA 2.00 INCH | NO | 3 | 20250 | 60750 | |
| 686 | DIA 2.50 INCH | NO | 2 | 24030 | 48060 | |
| 687 | DIA 5.00 INCH | NO | 2 | 62775 | 125550 | |
| 688 | DIA 6.00 INCH | NO | 2 | 69930 | 139860 | |
| 689 | DIA 8.00 INCH | NO | 2 | 75938 | 151876 | |
| 690 | SUPPLY AND INSTALLATION OF CHECK VALVE | |||||
| 691 | DIA 1.00 INCH | NO | 2 | 5569 | 11138 | |
| 692 | DIA 5.00 INCH | NO | 2 | 80325 | 160650 | |
| 693 | DIA 6.00 INCH | NO | 2 | 97200 | 194400 | |
| 694 | DIA 8.00 INCH | NO | 2 | 138645 | 277290 | |
| 695 | SUPPLY AND INSTALLATION OF PIPE FLEXIBLE CONNECTORS. | |||||
| 696 | DIA 5.00 INCH | NO | 3 | 43470 | 130410 | |
| 697 | DIA 6.00 INCH | NO | 3 | 46575 | 139725 | |
| 698 | DIA 8.00 INCH | NO | 2 | 49140 | 98280 | |
| 699 | SUPPLY & INSTALLATION OF PRESSURE GAUGES COMPLETE WITH SIPHON & GAUGE COCK | NO | 22 | 11800 | 259600 | |
| 700 | SUPPLY AND INSTALLATION OF PIPE LINE THER-MOMETERS COMPLETE WITH THERMOWELLS | NO | 12 | 15255 | 183060 | |
| 701 | SUPPLY AND INSTALLATION OF DRAIN COCKS. | |||||
| 702 | DIA 0.75 INCH | NO | 50 | 5567 | 278350 | |
| 703 | DIA 1.00 INCH | NO | 1 | 7088 | 7088 | |
| 704 | SUPPLY AND INSTALLATION OF ISOLATION BALL VALVE. | |||||
| 705 | DIA 2.00 INCH | NO | 1 | 29160 | 29160 | |
| 706 | SUPPLY AND INSTALLATION OF AIR VENTS | |||||
| 707 | AUTOMATIC | NO | 9 | 12393 | 111537 | |
| 708 | SUPPLY AND INSTALLATION OF AIR PRESSURE REDUCING VALVE | |||||
| 709 | DIA 1.00 INCH | NO | 2 | 74858 | 149716 | |
| 710 | SUPPLY AND INSTALLATION OF AIR PRESSURE RELIEFE VALVE | |||||
| 711 | DIA 1.25 INCH | NO | 2 | 99765 | 199530 | |
| 712 | SUPPLY AND INSTALLATION OF GAS PRESSURE REGULATOR | NO | 1 | 101858 | 101858 | |
| 713 | SUPPLY AND INSTALLATION OF ELECTRICAL WORKS AS SPECIFIED AND AS SHOWN ON DRAWINGS | |||||
| 714 | a) | SUPPLY & INSTALLATION OF ELECTRICAL PANELS | ||||
| 715 | MCC-1 | NO | 1 | 1674750 | 1674750 | |
| 716 | MCC-2 | NO | 1 | 1558750 | 1558750 | |
| 717 | ACP-1 | NO | 1 | 144275 | 144275 | |
| 718 | ACP-2 | NO | 1 | 152250 | 152250 | |
| 719 | ACP-3 | NO | 1 | 144275 | 144275 | |
| 720 | ACP-4 | NO | 1 | 171100 | 171100 | |
| 721 | ACP-5 | NO | 1 | 323350 | 323350 | |
| 722 | ACP-6 | NO | 1 | 144710 | 144710 | |
| 723 | ACP-7 | NO | 1 | 141230 | 141230 | |
| 724 | ACP-8 | NO | 1 | 161675 | 161675 | |
| 725 | ACP-9 | NO | 1 | 138475 | 138475 | |
| 726 | ACP-10 | NO | 1 | 93235 | 93235 | |
| 727 | SUPPLY & INSTALLTAION OF POWER CABLES FROM ATS (AUTO TRANSFER SOURCE) PANEL IN "ELECTRICAL PANEL ROOM" AT BASEMENT-2 TO MCC-1 & MCC-2 IN HVAC PLANT ROOM, COMPLETE WITH G.I TRUCNH, HANGING, LUGS, GLANDS, ACCESSORIES & TERMINATIONS, COMPLETE IN ALL RESPECT. | |||||
| 728 | 300 mm² - 3 Core | RFT | 850 | 12071 | 10260350 | |
| 729 | 120 mm² - 1 Core | RFT | 850 | 1740 | 1479000 | |
| 730 | 70 mm² - 1 Core | RFT | 450 | 1037 | 466650 | |
| 731 | SUPPLY & INSTALLATION OF TRUNKING OF G.I SHEET (US GAUGE-16) FOR MAIN POWER CABLES FROM ATS TO MCC-1 & MCC-2 WITH HANGING ARRANGEMENT, COMPLETE IN ALL RESPECT. | |||||
| 732 | 18" X 3" | RFT | 245 | 2163 | 529935 | |
| 733 | INSTALLATION OF BMS TEMPERATURE & AUTOCONTROL WITH CONTROL VALVES (2-WAY), ACTUATORS, SENSORS AND CONTROLERS FOR AHUs SHOWN ON DRAWING COMPLETE WITH CONDUITING AND WIRING. | NO | 3 | 195025 | 585075 | |
| 734 | INSTALLATION OF BMS TEMPERATURE & AUTOCONTROL FOR HVAC PLANT ROOM AND COOLING TOWERS, COMPLETE WITH MOTORIZED VALVES, ACTUATORS, SENSORS, CONTROLER, SOFTWARE (LIFETIME LICENCED), COMPUTER & PRINTER INCLUDING SUPERVISORY CONTROL, AS SHOWN ON DRAWING. | NO | 1 | 1312250 | 1312250 | |
| 735 | INSTALLATION OF BMS TEMPERATURE & AUTOCONTROL WITH SENSORS AND CONTROLERS FOR DSAC's SHOWN ON DRAWING. | NO | 2 | 232435 | 464870 | |
| 736 | INSTALLATION OF BMS CONTROL FOR PARKING VENTILATION FANS AT BASEMENTS WITH CARBON MONOXIDE (CO) SENSORS AS SHOWN ON DRAWING, COMPLETE WITH CONDUITING AND WIRING. | LOT | 1 | 703250 | 703250 | |
| 737 | PERFORMANCE TEST OF ONE CHILLER AND PRESHIPMENT INSPECTION OF ALL AHUs AT MANUFACTURER FACILITIES IN THE PRESENCE OF EMPLOYER, CONSULTANT, CONTRACTOR & MANUFACTURER, AS SPECIFIED IN TECHNICAL SPECIFICATIONS CLAUSE NO. 41 | JOB | 1 | 1250000 | 1250000 | |
| 738 | NOTE: PERFORMANCE TEST OF CHILLER SHALL BE CONDUCTED AT 100% LOAD AND CONDITIONS SPECIFIED IN EQUIPMENT SCHEDULE, REPORTS SHALL BE SUBMITTED DIRECTLY BY MANUFACTURER. | |||||
| 739 | OPERATION & MAINTENANCE FOR 1 YEAR PERIOD AFTER ISSUENCE OF SUBSTANTIAL COMPLETION CERTIFICATE, AS SPECIFIED IN TECHNICAL SPECIFICATIONS CLAUSE NO. 39 | LOT | 1 | 9000000 | 9000000 | |
| 740 | PAINTING & EQUIPMENT IDENTIFICATION | LOT | 1 | 1125000 | 1125000 | |
| 741 | INSPECTION, TESTING COMMISSION AND AIR/WATER BALANCING | LOT | 1 | 1875000 | 1875000 | |
| 742 | SHOP AND AS-BUILT DRAWINGS | LOT | 1 | 1250000 | 1250000 | |
| 743 | CIVIL WORKS RELATED HVAC EQUIPMENT FOUNDATIONS CUTTING OF WALLS/SLAB, PATCHING, PLASTERING & FINISHING AND COORDINATION WITH OTHERS. | LOT | 1 | 3500000 | 3500000 | |
| 744 | Excavation or cutting of earth to required gradient for Horticulture and land scarping in any kinds of soil and disposal of surplus excavated stuff outside the limit as per drawing and instructions of the Engineer In-charge. | Sqm | 500 | 175 | 87500 | |
| 745 | Supply, stacking and dressing of approved garden soil (sweet earth) from approved source free from salt, pebbles and grass roots etc including all leads &lifts, complete in all respects as per drawings and instructions of the Engineer In-charge. | Cum | 150 | 1155 | 173250 | |
| 746 | Supply, stacking and spreading of approved cowding manure from approved source free from pebbles and grass roots etc including all leads &lifts, complete in all respects as per drawings and instructions of the Engineer In-charge. | Sqm | 1000 | 165 | 165000 | |
| 747 | Supply of american grass including all leads an lifts and grassing fine by dibbling grass roots including watering, weeding till such time the grass is set and becomes green and is fit for removing complete in all respects as per drawings and instructions of the Engineer In-charge. | Sqm | 850 | 390 | 331500 | |
| 748 | Supply of approved INDOOR PLANTS including clay pot ,all leads an lifts etc complete in all respects and instructions of the Engineer In-charge. | Each | 100 | 5500 | 550000 | |
| 749 | Providing & Planting a Tree incl preparing a Tree Pit (size 900mm. X 900 mm. X 900mm.) by excavation, termite treatment in form of 20ml of any approved anti termite per plant on the walls & base of the pit,filling the pit with compost (ratio 1 manure : 3 sweet earth: 1 sand by volume) , transportation and mixing of soil improvement nutrients as required in all pits , DAP, Urea, etc. as per good horticultural practices, flooding with water at least 20 ltr. Per plant , dressing ,removal of rubbish & surplus earth if any with all leads & lifts, all locations specified. Maintenance of plants for a period of 24 months, replacement of any dead & sickly plants in this period, spraying of insecticides as requiredand complete in all respects as per botanical name, drawings and instructions of the Engineer In-charge. | |||||
| 750 | a) Fruit plants as required | Each | 30 | 2500 | 75000 | |
| 751 | b) Miscellaneous Trees | Each | 30 | 2500 | 75000 | |
| 752 | c) Lawn trees/ plants | Each | 30 | 2500 | 75000 | |
| 753 | d) Permanent flower plants | Each | 100 | 2500 | 250000 | |
| 754 | Providing & planting a Shrub incl preparing a Shrub Pit (size 450mm. X 450 mm. X 450mm.) by excavation, termite treatment in form of 15 ml of any approved anti termite per plant on the walls & base of the pit, filling the pit with compost. (ratio 1 manure : 3 sweet earth : 1 sand by volume) , DAP, Urea, transportation and mixing of soil as required in all pits, flooding with water at least 15 ltr. Per plant , dressing , removal of rubbish & surplus earth if any with all leads & lifts, planting in full and final location specified, maintenance of plants for a period of 24 months, replacement of any dead & sickly plants in this period, spraying of insecticides as required, as per botanical name & specification mentioned hereunder, complete in all respects as per drawings and instructions of the Engineer In-charge. | |||||
| 755 | a) Rangoon Creeper Double | Each | 30 | 2500 | 75000 | |
| 756 | b) Golden Shower | Each | 30 | 2500 | 75000 | |
| 757 | c) Sinacio | Each | 30 | 2500 | 75000 | |
| GRAND TOTAL: | Rs 1,846,842,456.83 |
Technical Evaluation Criteria
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
The Supplier is:
The title of the subject procurement is: CDA TEST Procurement
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator
Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
+92-331-506-6282
usamakausar.062@gmail.com
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator
Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
+92-331-506-6282
usamakausar.062@gmail.com
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 2.00% to 2.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 0% of the contract price in acceptable form of Nil
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
For being Brand New, bearing relevant reference numbers of the equipment (Certificate from supplier)
For Physical Fitness having No Damages (Certificate from supplier)
For the Country of Origin as quoted by the Supplier (Certificate from manufacturer)
For conformance to specifications and performance parameters, through Prior to delivery inspection (Inspection Report by Procurement Committee / Inspection Team)
For successful operation at site after complete installation, testing and commissioning of the equipment (Installation, Testing and Commissioning Report by Procurement Committee / Inspection Team)
Copies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount;
Original and two copies of the usual transport document (for example, a negotiable bill of lading, a non-negotiable sea waybill, an inland waterway document, an air waybill, a railway consignment note, a road consignment note, or a multimodal transport document) which the buyer may require to take the goods;
Copies of the packing list identifying contents of each package;
Insurance Certificate;
Manufacturer’s or Supplier’s Valid Warranty Certificate;
Inspection Certificate issued by the Nominated Inspection Agency (if any), and the Supplier’s Factory Inspection Report;
Certificate of Origin.
The above documents would be required even if the equipment has already been imported and is available with the supplier ex-stock
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P54935
To: FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., CDA TEST Procurement (P54935) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: FPPRA (Federal Public Procurement Regulatory Authority (PPRA)), Assistant Network Administrator Office # 201(B), Second Floor, Evacuee Trust Complex, Islamabad., Islamabad Capital Territory
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}