In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA
Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
+92-334-856-6622
ammarpavero@gmail.com
The following specific data for the procurement of works shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITBs). Whenever there is a conflict, the provisions herein shall prevail over those in ITBs.
ITB Number 1.1
Name of Procuring agency/Employer: Capital Development Authority (Works Directorate)
The subject of procurement is: WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.
Period for completion of the works 4 Months
Commencement date execution of the works: 14 Days
Type of Procurement: Local
ITB Number 2.1
Financial year for the operations of the Procuring agency/Employer: 2026-27Name of Project [insert: name and summary description of the Project if any]
Name of financing institution: [insert: name if any]
Name and identification number of the Contract: P63434
ITB Number 3.1
JV/Consortium or Association Allowed: Yes
Maximum number of members in the joint venture shall be: 3.
ITB Number 6.4
The Bidders may seek clarifications through EPADS v2.0: Last Clarification Date: Thursday, July 23, 2026
ITB Number 8.1
The Language of all correspondences and documents related to the Bid is: English
ITB Number 5.1 & 9.1
The following documents must be included to constitute the Bid
ITB Number 9.4 (b)
Other procurement specific documentation requirements are:
The bidder shall submit with its pricedbid the following documents to be uploded on E-PADS
ITB Number 12.4
The Bid price will be/will not be subject to the price adjustment Nil.
ITB Number 12.6
The Bid price shall be adjusted in accordance with Schedule-A to Bid – “Schedule of Adjustment Data” if available.
ITB Number 13.1
Bidders to quote entirely in Pak rupees (PKR)
ITB Number 15.1
The Bid Validity period shall be 120 Days days.
ITB Number 16.1
The amount of Bid Security shall be (insert amount)
The currency of the Bid Security shall be: PKR.
ITB Number 16.2
The Bid Security shall be in the form of: Pay Order, Call at Deposit
ITB Number 19.1
The deadline for Bid submission is: Friday, July 31, 2026 11:30 AM
Address for submission of Original Bid Security: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
ITB Number 21.1
The Bid opening shall take place at: EPADS v2.0
Day : Friday
Date: July 31, 2026
Time : 12:00 PM
ITB Number 27.1
The currency that shall be used for Bid evaluation and comparison purposes to convert all Bid prices expressed in various currencies is: PKR Only
The source of exchange rate shall be: Nil
The date of exchange rate shall be: Nil
ITB Number 28.2 & 28.5
Least Cost Based Selection (LCBS)
see Evaluation Criteria
ITB Number 29.1
Domestic preference to apply.
Domestic preference: No
Preference to domestic or national suppliers or contractors shall be provided in accordance with policies of the Federal Government and/or in accordance with the regulations issued by the Authority.
If Yes, The percentage for the domestic preference alongwith calculation formula is provided in the evaluation and qualification criteria.
ITB Number 32.2
Sub-contracting is allowed? : No
No % of the total value of the contract.
39.1 The Performance Security (or guarantee) shall be 10.00%
39.2 The Performance Security (or guarantee) shall be in the form of: Bank Guarantee
| Bidder's Type | Required Registration |
|---|---|
| Sole Proprietorship Partnership Firm Company (Private Limited) Company (Public Limited) Company (Limited by Guarantee) State Owned Enterprise (Private Limited) State Owned Enterprise (Public Limited) | NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) FBR (GSTN) PEC |
| Eligibility Criteria | Document |
|---|---|
| The Contractor/Firm having valid registration for the year 2026-27 with Pakistan Engineering Council in Category C-3 or above with specialization codes CE-01, CE-09, CE-10, EE-02, EE-04, EE-06, EE-07 & ME-02 are eligible to apply. | Yes |
| The bidder shall submit written power of Attorney authorizing the signatory of the bid to act for and on behalf of the bidder. The name and position held be each person signing the authorization must be typed or printed below the signature. | Yes |
Least Cost Based Selection (LCBS)
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 70 | |
| WORKING EXPERIENCE | ||
| Number of completed contracts of public sector Sports Facility Related works (i.e. Government or Semi Government organization or autonomous bodies or authorities) of minimum value of 60 % of the laydown cost of the project completed in the last 10 years.
**NOTE**
In case of Joint Venture, the working experience of leader of the Joint Venture shall be evaluated.
**DOCUMENTATION REQUIREMENT**
The bidder must upload Project Award Letter, Work Orders or Contract Agreement & completion Certificates and other documents necessary for confirming scope of works i.e. BOQs, IPC’s etc.
The bidder must upload joint venture agreement in case of projects is executed as a partner of joint venture clearly showing scope of works and percentage share of all partners of joint venture. To comply with the criteria, the share of bidder under the joint venture for similar works must be equal or exceeding the qualification criteria and requirement (Quantitative)(Doc Required) 2 Completed Contracts (20) 1 Completed Contract (10) | 20 | |
| Number of on-going contracts of public sector Sports Facility Related works (i.e. Government or Semi Government organization or autonomous bodies or authorities) of minimum value of 70 % of the laydown cost of the project completed in the last 10 years.
**NOTE**
In case of Joint Venture, the working experience of leader of the Joint Venture shall be evaluated.
**DOCUMENTATION REQUIREMENT**
The bidder must upload Project Award Letter, Work Orders or Contract Agreement & completion Certificates and other documents necessary for confirming scope of works i.e. BOQs, IPC’s etc.
The bidder must upload joint venture agreement in case of projects is executed as a partner of joint venture clearly showing scope of works and percentage share of all partners of joint venture. To comply with the criteria, the share of bidder under the joint venture for similar works must be equal or exceeding the qualification criteria and requirement (Quantitative)(Doc Required) 2 On going Contracts (20) 1 On going Contract (10) | 20 | |
| **EQUIPMENT CAPABILITIES** | ||
| Concrete Batching Plant (1 m3 Capacity or above) (01) (Quantitative)(Doc Required) | 4 | |
| Mobile Concrete Transit Mixers (6 Cum Capacity or above) (02) (Quantitative)(Doc Required) 02 nos. (4) 01 no. (2) | 4 | |
| Mobile Crane (01 no.) (Quantitative)(Doc Required) | 2 | |
| Generator (50KVA) (01 no.) (Quantitative)(Doc Required) | 2 | |
| Tractor Trolley/ Dumper (02 nos.) (Quantitative)(Doc Required) 02 nos. (2) 01 NO. (1) | 2 | |
| Water Tanker (01 no.) (Quantitative)(Doc Required) | 1 | |
| **PERSONNEL CAPABILITIES** | ||
| Project Manager (01 No.) • BSc Civil Engineering • registration with PEC as Registered Engineer • At least 15 years’ of Professional Experience (Quantitative)(Doc Required) | 5 | |
| Site Engineer (Civil) (01 No.) • BSc Civil Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required) | 5 | |
| Site Engineer (E&M) • BSc Electrical/Mechanical/Mechatronic Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required) | 4 | |
| Material Engineer • BSc Civil/ Geological Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required) | 2 | |
| Supervisor (Civil) • Diploma in Civil (DAE) • at least 5 years’ experience in building and road works (Quantitative)(Doc Required) | 1 | |
| Supervisor (E&M) • Diploma in Electrical (DAE) • at least 5 years’ experience in building and road works (Quantitative)(Doc Required) | 1 | |
| Quantity Surveyor • Diploma (DAE)/Relevant Certificate • at least 5 years’ experience in building project estimation (Quantitative)(Doc Required) | 1 | |
| Surveyor • Diploma in Civil (DAE) /Relevant Certificate • at least 5 years’ experience in building and road works (Quantitative)(Doc Required) | 1 | |
| **FINANCIAL SOUNDNESS** | ||
| Financial Resources (Contract/Project Specific Bank Credit Line) (Quantitative)(Doc Required) Contract/Project Specific Bank Credit Line PKR 224 Million or above (15) Contract/Project Specific Bank Credit Line less than PKR 224 Million and more than or equal to PKR 210 Million (14) Contract/Project Specific Bank Credit Line less than PKR 210 Million and more than or equal to PKR 196 Million (13) Contract/Project Specific Bank Credit Line less than PKR 196 Million and more than or equal to PKR 182 Million (12) Contract/Project Specific Bank Credit Line less than PKR 182 Million and more than or equal to PKR 168 Million (11) Contract/Project Specific Bank Credit Line less than PKR 168 Million and more than or equal to PKR 154 Million (10) Contract/Project Specific Bank Credit Line less than PKR 154 Million and more than or equal to PKR 140 Million (9) Contract/Project Specific Bank Credit Line less than PKR 140 Million and more than or equal to PKR 126 Million (8) | 15 | |
| Average Annual Construction Turnover in last 3 years, evaluated through the bidder’s, Audited financial statements for the last three (03) years. (Quantitative)(Doc Required) Average Annual Construction Turnover of PKR 220 million or above. (10) Average Annual Construction Turnover less than PKR 220 million and more than or equal to PKR 200 Million. (9) Average Annual Construction Turnover less than PKR 200 million and more than or equal to PKR 180 Million. (8) Average Annual Construction Turnover less than PKR 180 million and more than or equal to PKR 160 Million. (7) Average Annual Construction Turnover less than PKR 160 million and more than or equal to PKR 140 Million. (6) Average Annual Construction Turnover less than PKR 140 million and more than or equal to PKR 120 Million. (5) | 10 | |
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| Wellness Complex | Address: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, IslamabadSchedule: 120 DaysQuantity: 1/job |
1/job | 14897491 PKR |
Jobs Without Lots :
Job: Wellness Complex
Specifications / Requirements:
| Sr. No | Ref. No. | Description | Unit | Qty | Rate | Rate in Words | Amount |
|---|---|---|---|---|---|---|---|
| 1 | **RECEPTION/BILLIARD/TABLE-TENNIS** | ||||||
| 2 | **CIVIL WORKS** | ||||||
| 3 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 4 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 2.7 | 12266.7 | 33120.09 | |
| 5 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 1.44 | 8155.5 | 11743.92 | |
| 6 | ii) With new earth excavated from outside lead upto one chain (30 m). | 1000 Cft | 1.86 | 17545.5 | 32634.63 | ||
| 7 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 8 | (h) | Ratio 1:3:6 | 100 Cft | 0.26 | 40827.38 | 10615.1188 | |
| 9 | (i) | Ratio 1:4:8 | 100 Cft | 9.56 | 35592.28 | 340262.1968 | |
| 10 | 06-06 | Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.). | |||||
| 11 | a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift. | ||||||
| 12 | (2) Type B (nominal mix 1:1½: 3) | Per Cft | 2045 | 853.53 | 1745468.85 | ||
| 13 | (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects: including all lead and lift. | ||||||
| 14 | (2) Type B (nominal mix 1:1½: 3) | ||||||
| 15 | (i) Upto 9" thick (Avg) | Per Cft | 68 | 823.28 | 55983.04 | ||
| 16 | (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift. | ||||||
| 17 | (2) Type B (nominal mix 1: 1½: 3) | Per Cft | 762 | 700.58 | 533841.96 | ||
| 18 | 06-12 | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars). | |||||
| 19 | (b) Deformed bars | ||||||
| 20 | ii) Grade-60 | 100kg | 118.7 | 28479.6 | 3380528.52 | ||
| 21 | **BRICK WORK** | ||||||
| 22 | 07-05 (i) | Pacca brick work in 1:4 C/S mortar in Ground floor | 100 Cft | 16.67 | 42181.95 | 703173.1065 | |
| 23 | **ROOFING** | ||||||
| 24 | 09-15 | Khuras on roof 2'x2'x6" (600 x 600 x 150 mm) | Each | 4 | 1228.55 | 4914.2 | |
| 25 | 09-35 (iii) | Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick | 100 Sft | 17.33 | 19751.6 | 342295.228 | |
| 26 | 09-46 | Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain | |||||
| 27 | i) 3 mm thick | Per Sft | 1733 | 125.15 | 216884.95 | ||
| 28 | 09-48 | Providing and fixing false ceiling comprises of Gypsum board laminated sheet of size 2'x2'/2'x3'/ 3'x3'of specified design and thickness i/c cost of fixtures i.e galvanized angle 1" x 1" at wall sides, galvanized tee 1¼" x 1"and 1 ½” x 1” both at 4’ c/c ( made of Taiwan CKM or equivalent),hanging with G.I/Copper wire 16 SWG, G.I hook, Rawal Plug etc:complete in all respects as approved and directed by the Engineer Incharge | |||||
| 29 | iv) 12 mm thick | Per Sft | 1535 | 182.25 | 279753.75 | ||
| 30 | **FLOORING** | ||||||
| 31 | 06-02 | Dry rammed brick or stone ballast, 1½" to 2" ( 40 mm to 50 mm) gauge. | 100Cft | 7.28 | 14076.5 | 102476.92 | |
| 32 | 10-14 | Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm) | 100 Sft | 5.76 | 21668.65 | 124811.424 | |
| 33 | 10-46-a | Providing and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") | Per Sft | 1535 | 501.05 | 769111.75 | |
| 34 | 10-36 | Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge | |||||
| 35 | a) Full body Glazed tiles | ||||||
| 36 | (iv) 600mmx 1200 mm (24"x48") | Per Sft | 613 | 501.2 | 307235.6 | ||
| 37 | 10-47 | Providing and laying flooring with China Verona Marble having uniform texture (Spotless) of required size and specified thickness, with adhesive bond over 3/4" thick bedding of (1:2) cement sand mortor i/c the cost of matching sealer,cutting, grinding and chemical polishing complete in all respect as approved and directed by the Engineer Incharge. ii) 3/4" thick (12"x24"/12"x36") | Per Sft | 120 | 538 | 64560 | |
| 38 | 10-48 | Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Risers/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White | Per Sft | 66 | 2015.75 | 133039.5 | |
| 39 | 10-49 | Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. | Per Rft | 42 | 39.9 | 1675.8 | |
| 40 | **SURFACE RENDERING** | ||||||
| 41 | 11-9(b) | Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick | 100 Sft | 37.21 | 4923.45 | 183201.5745 | |
| 42 | 11-9(c) | Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick | 100 Sft | 23.72 | 6585.35 | 156204.502 | |
| 43 | 11-12 | Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3 | 100 Sft | 0.58 | 5624.75 | 3262.355 | |
| 44 | **DOORS AND WINDOWS** | ||||||
| 45 | 12-64 | Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge | Each | 3 | 4569.55 | 13708.65 | |
| 46 | 12-30 | Providing and fixing approved quality rim lock adjustable over the style surface | Each | 4 | 1680 | 6720 | |
| 47 | 12-13 | P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge. | Per Sft | 81 | 916.45 | 74232.45 | |
| 48 | 12-18 | Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc | |||||
| 49 | b) Deodar wood | Per Sft | 81 | 1075.45 | 87111.45 | ||
| 50 | 25-50 | Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick Glass | Per Sft. | 123 | 1799.55 | 221344.65 | |
| 51 | 25-55 | providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick Glass | Per Sft. | 628 | 2764.35 | 1736011.8 | |
| 52 | 25-52 | Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect. | Per Sft. | 316 | 538.3 | 170102.8 | |
| 53 | **PAINTING AND VARNISHING** | ||||||
| 54 | 13-31 | Preparing surface and painting emulsion paint : | |||||
| 55 | a) 1st coat | 100 Sft | 37.79 | 1760.75 | 66538.7425 | ||
| 56 | b) 2nd & each subsequent coat. | 100 Sft | 75.58 | 1361.75 | 102921.065 | ||
| 57 | 13-33, 13-31 | Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh | |||||
| 58 | i) 1st coat | 100 Sft | 180 | 5271 | 948780 | ||
| 59 | ii) 2nd & each subsequent coat. | 100 Sft | 360 | 3038.4 | 1093824 | ||
| 60 | 13-9 | Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m) | 100 Sft | 13.27 | 2821.7 | 37443.959 | |
| 61 | **IRON WORKS** | ||||||
| 62 | **MISCELLANEOUS** | ||||||
| 63 | 26-43 | Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge | Sft | 5638 | 12.7 | 71602.6 | |
| 64 | **NON-SCHEDULED ITEM** | ||||||
| 65 | NSI-01 | Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects. | Sft. | 615 | 110 | 67650 | |
| 66 | NSI-02 | Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer. | Each | 3 | 50000 | 150000 | |
| 67 | NSI-03 | Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area. | Sft | 1186 | 440 | 521840 | |
| 68 | NSI-04 | Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects. | Sft | 1186 | 2500 | 2965000 | |
| 69 | **CAFÉ** | ||||||
| 70 | **CIVIL WORKS** | ||||||
| 71 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 72 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 5.12 | 12266.7 | 62805.504 | |
| 73 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 3 | 8155.5 | 24466.5 | |
| 74 | ii) | ii) With new earth excavated from outside lead upto one chain (30 m). | 1000 Cft | 0.25 | 17545.5 | 4386.375 | |
| 75 | **CONCRETE** | ||||||
| 76 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 77 | (h) | Ratio 1:3:6 | 100 Cft | 0.3 | 40827.38 | 12248.214 | |
| 78 | (i) | Ratio 1:4:8 | 100 Cft | 14.06 | 35592.28 | 500427.4568 | |
| 79 | 06-06 | Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.). | |||||
| 80 | a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift. | ||||||
| 81 | (2) Type B (nominal mix 1:1½: 3) | Per Cft | 11091.33 | 853.53 | 9466782.8949 | ||
| 82 | (3) Type C (nominal mix 1: 2: 4) | Per Cft | 54 | 778.78 | 42054.12 | ||
| 83 | (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects: including all lead and lift. (Water Tank Walls) | ||||||
| 84 | (2) Type B (nominal mix 1:1½: 3) | ||||||
| 85 | (i) Upto 9" thick (Avg) | Per Cft | 230 | 823.28 | 189354.4 | ||
| 86 | (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift. | ||||||
| 87 | (2) Type B (nominal mix 1: 1½: 3) | Per Cft | 1527 | 700.58 | 1069785.66 | ||
| 88 | 06-12 | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars). | |||||
| 89 | (b) Deformed bars | ||||||
| 90 | ii) Grade-60 | 100kg | 549 | 28479.6 | 15635300.4 | ||
| 91 | 06-32 | Providing and embedding 10" (250mm) wide PVC water stopper in expansion joints of RCC structures (Retaining walls, water tanks, Slabs) complete in all respect. | |||||
| 92 | ii) 10 mm thick | Rft | 60 | 816 | 48960 | ||
| 93 | **BRICK WORK** | ||||||
| 94 | 07-05 (i) | Pacca brick work in 1:4 C/S mortar in Ground floor | 100 Cft | 119.08 | 42181.95 | 5023026.606 | |
| 95 | 07-06-i | Pacca brick work in 1:4 C/S mortar.'Add extra labour on item No. 5 for brickwork in (i) first floor:- | 100 Cft | 20.77 | 1793.45 | 37249.9565 | |
| 96 | **ROOFING** | ||||||
| 97 | 09-15 | Khuras on roof 2'x2'x6" (600 x 600 x 150 mm) | Each | 4 | 1228.55 | 4914.2 | |
| 98 | 09-35 (iii) | Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick | 100 Sft | 24.04 | 19751.6 | 474828.464 | |
| 99 | 09-46 | Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain | |||||
| 100 | i) 3 mm thick | Per Sft | 2404 | 125.15 | 300860.6 | ||
| 101 | 09-48 | Providing and fixing false ceiling comprises of Gypsum board laminated sheet of size 2'x2'/2'x3'/ 3'x3'of specified design and thickness i/c cost of fixtures i.e galvanized angle 1" x 1" at wall sides, galvanized tee 1¼" x 1"and 1 ½” x 1” both at 4’ c/c ( made of Taiwan CKM or equivalent),hanging with G.I/Copper wire 16 SWG, G.I hook, Rawal Plug etc:complete in all respects as approved and directed by the Engineer Incharge | |||||
| 102 | iv) 12 mm thick | Per Sft | 1809 | 182.25 | 329690.25 | ||
| 103 | 09-50 | Providing and fixing Drywall Partition (4" thick) which consist of Gypsum Board sheet screwed to G.I Track U Channel (72mm x 32mmx 32mm x 0.50mm thick) fixed at top & bottom and G.I Studs (C-Channel) size (70mm x 34mm x 36mm x 0.50mm thick) equal vertical interval @ 2' C/C fit within the channel sections to form the frame work, including 12mm gypsum board (confirming to ASTM 1396) on both sides with infill insulation material (rockwool) i/c of jointing compound, self adhesive fiberglass tape for covering the joints between the drywall panels, corner angle bead, Smart Screws (3.5mm x 25mm), flex metal corner tape, for smooth and homogeneous look, grinding the exposed compound with abrasive paper, complete in all respects, as per specification and as approved by the Engineer incharge | Per Sft | 138 | 464.65 | 64121.7 | |
| 104 | **FLOORING** | ||||||
| 105 | 06-02 | Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge. | 100Cft | 9.56 | 14076.5 | 134571.34 | |
| 106 | 10-14 | Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm) | 100 Sft | 6.48 | 21668.65 | 140412.852 | |
| 107 | 10-35 | Mosaic dado or skirting with one part of cement and marble powder in the ratio of 3:1 and two parts of marble chips, laid over ½"(13 mm) thick cement plaster 1:3, including rubbing and polishing, complete with finishing: (a) using grey cement: i) 1/2"(13 mm) thick | 100 Sft | 4.5 | 20075.65 | 90340.425 | |
| 108 | 10-46-a | Providing and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") | Per Sft | 4500 | 501.05 | 2254725 | |
| 109 | 10-36 | Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge | |||||
| 110 | a) Full body Glazed tiles | ||||||
| 111 | (iv) 600mmx 1200 mm (24"x48") | Per Sft | 1946 | 501.2 | 975335.2 | ||
| 112 | 10-47 | Providing and laying flooring with China Verona Marble having uniform texture (Spotless) of required size and specified thickness, with adhesive bond over 3/4" thick bedding of (1:2) cement sand mortor i/c the cost of matching sealer,cutting, grinding and chemical polishing complete in all respect as approved and directed by the Engineer Incharge. ii) 3/4" thick (12"x24"/12"x36") | Per Sft | 69 | 538 | 37122 | |
| 113 | 10-48 | Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White | Per Sft | 402 | 2015.75 | 810331.5 | |
| 114 | 10-49 | Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. | Per Rft | 205 | 39.9 | 8179.5 | |
| 115 | 10-50 | Extra cost for making hole in Marble slab for fixtures, Sink,burners,basin Vanities i/c cost of bevelling of internal edge as approved and directed by the Engineer Incharge. | Each | 2 | 980.7 | 1961.4 | |
| 116 | 10-51 | Providing and laying Prepolished Granite of specified thickness and shade of full width of approved quality laid with adhesive bond over 3/4" thick (1:2) cement sand mortor bed , complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 117 | (i) 3/4" thick | Per Sft | 81 | 1181.2 | 95677.2 | ||
| 118 | 10-19 | Extra labour for each storey above ground, for mosaic, conglomerate, tiles, stone and wooden floor.(First floor) | 100 Sft | 30.08 | 1218.1 | 36640.448 | |
| 119 | **SURFACE RENDERING** | ||||||
| 120 | 11-9(b) | Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick | 100 Sft | 72.08 | 4923.45 | 354882.276 | |
| 121 | 11-29 | Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30') | 100 Sft | 24.63 | 659.45 | 16242.2535 | |
| 122 | 11-9(c) | Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick | 100 Sft | 42.72 | 6585.35 | 281326.152 | |
| 123 | 11-29 | Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30') | 100 Sft | 24.06 | 659.45 | 15866.367 | |
| 124 | 11-12 | Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3 | 100 Sft | 4.17 | 5624.75 | 23455.2075 | |
| 125 | 11-29 | Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30') | 100 Sft | 3.58 | 659.45 | 2360.831 | |
| 126 | **DOORS AND WINDOWS** | ||||||
| 127 | 12-13 | P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge. | Per Sft | 77 | 916.45 | 70566.65 | |
| 128 | 12-18 | Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc | |||||
| 129 | b) Deodar wood | Per Sft | 77 | 1075.45 | 82809.65 | ||
| 130 | 12-64 | Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge | Each | 2 | 4569.55 | 9139.1 | |
| 131 | 12-30 | Providing and fixing approved quality rim lock adjustable over the style surface | Each | 4 | 1680 | 6720 | |
| 132 | 25-50 | Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick Glass | Per Sft. | 117 | 1799.55 | 210547.35 | |
| 133 | 25-55 | providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick Glass | Per Sft. | 1752 | 2764.35 | 4843141.2 | |
| 134 | 25-52 | Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect. | Per Sft. | 876 | 538.3 | 471550.8 | |
| 135 | **PAINTING AND VARNISHING** | ||||||
| 136 | 13-31 | Preparing surface and painting emulsion paint : | |||||
| 137 | a) 1st coat | 100 Sft | 76.25 | 1760.75 | 134257.1875 | ||
| 138 | b) 2nd & each subsequent coat. | 100 Sft | 152.51 | 1361.75 | 207680.4925 | ||
| 139 | 13-31 | Extra labour for painting, varnishing, etc. from 20' (6.10 m)height and above, for every additional 10' (3.05 m) height,or part thereof, requiring scaffolding | 100 Sft | 28.21 | 259.85 | 7330.3685 | |
| 140 | 13-33, 13-31 | Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh | |||||
| 141 | i) 1st coat | 100 Sft | 6.89 | 5271 | 36317.19 | ||
| 142 | ii) 2nd & each subsequent coat. | 100 Sft | 13.78 | 3038.4 | 41869.152 | ||
| 143 | 13-9 | Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m) | 100 Sft | 23.8 | 2821.7 | 67156.46 | |
| 144 | **IRON WORKS** | ||||||
| 145 | 25-38 | Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer Incharge | Per Rft | 30 | 3387.45 | 101623.5 | |
| 146 | **MISCELLANEOUS** | ||||||
| 147 | 26-43 | Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge | Sft | 6077 | 12.7 | 77177.9 | |
| 148 | **NON-SCHEDULED ITEM** | ||||||
| 149 | NSI-01 | Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects. | Sft. | 1635 | 110 | 179850 | |
| 150 | NSI-02 | Supply and installation of Wood Plastic Composite (WPC) ceiling panels, manufactured from weather‑resistant composite material, designed to be durable, moisture‑proof, termite‑proof, and low maintenance. Installation shall include all necessary fixtures, fasteners, and accessories, and complete in all respects as per drawings and as directed by The Engineer’s instructions. | Sft. | 2499 | 1000 | 2499000 | |
| 151 | NSI-03 | Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects. | Sft. | 162 | 1020 | 165240 | |
| 152 | NSI-04 | Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer. | Each | 3 | 50000 | 150000 | |
| 153 | NSI-05 | Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area. | Sft | 3339 | 440 | 1469160 | |
| 154 | NSI-06 | Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects. | Sft | 3339 | 2500 | 8347500 | |
| 155 | **GYM** | ||||||
| 156 | **CIVIL WORKS** | ||||||
| 157 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 158 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 26.18 | 12266.7 | 321142.206 | |
| 159 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 18.37 | 8155.5 | 149816.535 | |
| 160 | ii) | ii) With new earth excavated from outside lead upto one chain (30 m). | 1000 Cft | 3.62 | 17545.5 | 63514.71 | |
| 161 | **CONCRETE** | ||||||
| 162 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 163 | (h) | Ratio 1:3:6 | 100 Cft | 1.18 | 40827.38 | 48176.3084 | |
| 164 | (i) | Ratio 1:4:8 | 100 Cft | 25.52 | 35592.28 | 908314.9856 | |
| 165 | 06-06 | Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.). | |||||
| 166 | a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift. | ||||||
| 167 | (2) Type B (nominal mix 1:1½: 3) | Per Cft | 10116 | 853.53 | 8634309.48 | ||
| 168 | (3) Type C (nominal mix 1: 2: 4) | Per Cft | 13 | 778.78 | 10124.14 | ||
| 169 | (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects:including all lead and lift. | ||||||
| 170 | (2) Type B (nominal mix 1:1-1/2:3) | ||||||
| 171 | (i) Upto 9" thick (Avg) | Per Cft | 1971 | 823.28 | 1622684.88 | ||
| 172 | (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:- including all lead and lift. | ||||||
| 173 | (2) Type B (nominal mix 1: 1½: 3) | Per Cft | 5617 | 700.58 | 3935157.86 | ||
| 174 | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars). | ||||||
| 175 | (b) Deformed bars | ||||||
| 176 | ii) Grade-60 | 100kg | 682.7 | 28479.6 | 19443022.92 | ||
| 177 | Providing and embedding 10" (250mm) wide PVC water stopper in expansion joints of RCC structures (Retaining walls, water tanks, Slabs) complete in all respect. | ||||||
| 178 | ii) 10 mm thick | Rft | 122 | 816 | 99552 | ||
| 179 | **BRICK WORK** | ||||||
| 180 | 07-4(i) | Pacca brick work in 1:4 C/S mortar in foundation and upto plinth top:- | 100Cft | 0.54 | 41153.25 | 22222.755 | |
| 181 | 07-05 (i) | Pacca brick work in 1:4 C/S mortar in Ground floor | 100 Cft | 57.13 | 42181.95 | 2409854.8035 | |
| 182 | 07-06-i | Pacca brick work in 1:4 C/S mortar.'Add extra labour on item No. 5 for brickwork in (i) first floor:- | 100 Cft | 19.13 | 1793.45 | 34308.6985 | |
| 183 | **ROOFING** | ||||||
| 184 | 09-15 | Khuras on roof 2'x2'x6" (600 x 600 x 150 mm) | Each | 4 | 1228.55 | 4914.2 | |
| 185 | 09-35 (iii) | Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick | 100 Sft | 46.84 | 19751.6 | 925164.944 | |
| 186 | 09-46 | Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain | |||||
| 187 | i) 3 mm thick | Per Sft | 7410 | 125.15 | 927361.5 | ||
| 188 | **FLOORING** | ||||||
| 189 | 06-02 | Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge. | 100Cft | 12.52 | 14076.5 | 176237.78 | |
| 190 | 10-14 | Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm) | 100 Sft | 8.7 | 21668.65 | 188517.255 | |
| 191 | 10-16 | Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick | 100 Sft | 3.9 | 16609.8 | 64778.22 | |
| 192 | 10-35 | Mosaic dado or skirting with one part of cement and marble powder in the ratio of 3:1 and two parts of marble chips, laid over ½"(13 mm) thick cement plaster 1:3, including rubbing and polishing, complete with finishing: (a) using grey cement: i) 1/2"(13 mm) thick | 100 Sft | 2 | 20075.65 | 40151.3 | |
| 193 | 10-39 | Providing and laying 1" thick terrazo tile for specified colour & size full body, best quality with minimum 5000 PSI in approved design with adhesive bond over 3/4" thick 1:3 cement plaster i/c the cost of sealer for finishing the joints i/c cutting, grinding, rubbing, filling Complete in all respect as approved and directed by the Engineer incharge. (Without Polishing) b) Size 24"x24"x1" ii) Coloured | Sft | 1414 | 405.05 | 572740.7 | |
| 194 | 10-46-a | Providing and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") | Per Sft | 3510 | 501.05 | 1758685.5 | |
| 195 | 10-36 | Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge | |||||
| 196 | a) Full body Glazed tiles | ||||||
| 197 | (iv) 600mmx 1200 mm (24"x48") | Per Sft | 4341 | 501.2 | 2175709.2 | ||
| 198 | 10-48 | Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Risers/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White | Per Sft | 355 | 2015.75 | 715591.25 | |
| 199 | 10-49 | Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. | Per Rft | 181 | 39.9 | 7221.9 | |
| 200 | 10-50 | Extra cost for making hole in Marble slab for fixtures, Sink,burners,basin Vanities i/c cost of bevelling of internal edge as approved and directed by the Engineer Incharge. | Each | 5 | 980.7 | 4903.5 | |
| 201 | 10-51 | Providing and laying Prepolished Granite of specified thickness and shade of full width of approved quality laid with adhesive bond over 3/4" thick (1:2) cement sand mortor bed , complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 202 | (i) 3/4" thick | Per Sft | 84 | 1181.2 | 99220.8 | ||
| 203 | 10-19 | Extra labour for each storey above ground, for mosaic, conglomerate, tiles, stone and wooden floor.(First floor) | 100 Sft | 0.91 | 1218.1 | 1108.471 | |
| 204 | **SURFACE RENDERING** | ||||||
| 205 | 11-9(b) | Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick | 100 Sft | 79.48 | 4923.45 | 391315.806 | |
| 206 | 11-29 | Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30') | 100 Sft | 36.29 | 659.45 | 23931.4405 | |
| 207 | 11-9(c) | Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick | 100 Sft | 54.84 | 6585.35 | 361140.594 | |
| 208 | 11-29 | Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30') | 100 Sft | 26.88 | 659.45 | 17726.016 | |
| 209 | 11-12 | Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3 | 100 Sft | 6.06 | 5624.75 | 34085.985 | |
| 210 | **PAINTING AND VARNISHING** | ||||||
| 211 | 13-31 | Preparing surface and painting emulsion paint : | |||||
| 212 | a) 1st coat | 100 Sft | 30.66 | 1760.75 | 53984.595 | ||
| 213 | b) 2nd & each subsequent coat. | 100 Sft | 61.32 | 1361.75 | 83502.51 | ||
| 214 | 13-33, 13-31 | Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh | |||||
| 215 | i) 1st coat | 100 Sft | 9.3 | 5271 | 49020.3 | ||
| 216 | ii) 2nd & each subsequent coat. | 100 Sft | 18.6 | 3038.4 | 56514.24 | ||
| 217 | **DOORS AND WINDOWS** | ||||||
| 218 | 12-64 | Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge | Each | 8 | 4569.55 | 36556.4 | |
| 219 | 25-50 | Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick Glass | Per Sft. | 73 | 1799.55 | 131367.15 | |
| 220 | 25-55 | providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick Glass | Per Sft. | 1001 | 2764.35 | 2767114.35 | |
| 221 | 25-61 | P/F Iron door comprising of specified leaves made of 1-1/4”x1-1/4”x3/16" MS angle iron for leaf frame, diagonal and horizontal braces duly welded with MS. sheet 18-SWG i/c the cost of sliding bolt, tower bolt and painting 3-coats but excluding the cost of Chowkat complete in all respect as approved and directed by the Engineer incharge (i) Single Leaf | Sft | 74 | 1083.75 | 80197.5 | |
| 222 | 12-05 | Providing and fixing 1st class solid wood wrought joinery in panelled or panelled and glazed doors and windows of specified thickness with 1" thick solid wood panels with step and 1-1/2"x2-1/2" beadings all around the panels i/c the cost of Tower bolt and handles complete in all respect (Excluding the cost of sliding bolt,lock and chowkats (frame), etc.) as approved and directed by the Engineer Incharge b) Ash wood Door (i) 2" thick (50 mm) | Sft | 157 | 3753.45 | 589291.65 | |
| 223 | 12-13 | P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge. | Per Sft | 140 | 916.45 | 128303 | |
| 224 | 12-18 | Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc | |||||
| 225 | b) Deodar wood | Per Sft | 297 | 1075.45 | 319408.65 | ||
| 226 | 25-52 | Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect. | Per Sft. | 501 | 538.3 | 269688.3 | |
| 227 | **PAINTING AND VARNISHING** | ||||||
| 228 | 13-9 | Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m) | 100 Sft | 51.22 | 2821.7 | 144527.474 | |
| 229 | **IRON WORKS** | ||||||
| 230 | 25-38 | Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer Incharge | Per Rft | 76 | 3387.45 | 257446.2 | |
| 231 | **MISCELLANEOUS** | ||||||
| 232 | 26-43 | Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge | Sft | 11053 | 12.7 | 140373.1 | |
| 233 | **NON-SCHEDULED ITEM** | ||||||
| 234 | **MISCELLANIES WORKS** | ||||||
| 235 | NSI-01 | Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects. | Sft. | 2494 | 110 | 274340 | |
| 236 | NSI-02 | Supply and installation of Wood Plastic Composite (WPC) ceiling panels, manufactured from weather‑resistant composite material, designed to be durable, moisture‑proof, termite‑proof, and low maintenance. Installation shall include all necessary fixtures, fasteners, and accessories, and complete in all respects as per drawings and as directed by The Engineer’s instructions. | Sft. | 830 | 1000 | 830000 | |
| 237 | NSI-03 | Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects. | Sft. | 8032 | 1020 | 8192640 | |
| 238 | NSI-04 | Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer. | Each | 3 | 50000 | 150000 | |
| 239 | NSI-05 | Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area. | Sft | 4086 | 440 | 1797840 | |
| 240 | NSI-6 | Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects, and directions of the Engineer-in-Charge, | Sft | 4086 | 2500 | 10215000 | |
| 241 | NSI-7 | Supply and installation of MR (Moisture Resistant) grade board lockers, complete with internal shelves as per requirement, finished with approved laminate finish, including premium quality hinges and hardware, such as handles, locks, screws, and fittings. and directions of The Engineer. | Sft | 264 | 6875 | 1815000 | |
| 242 | NSI-8 | Supply and installation of high-density gym rubber flooring, made from durable shock-absorbing rubber, slip-resistant, impact-resistant, and noise-reducing. Suitable for heavy gym equipment and high-traffic fitness areas. Installed complete with proper leveling and finishing.. and directions of The Engineer. | Sft | 4582 | 4200 | 19244400 | |
| 243 | NSI-9 | Three coats of Matt Enamel Paint of approved colour, including surface preparation by provision of a film with Alkali resisting primer to form smooth base for paint, including sand papering etc. , filling where required, etc. complete. | Sft | 3483 | 85 | 296055 | |
| 244 | **PEDAL COURT** | ||||||
| 245 | **CIVIL WORKS** | ||||||
| 246 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 247 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 0.06 | 12266.7 | 736.002 | |
| 248 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 0.05 | 8155.5 | 407.775 | |
| 249 | **CONCRETE** | ||||||
| 250 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 251 | (f) | Ratio 1:2:4 | 100 Cft | 7.68 | 47998.78 | 368630.6304 | |
| 252 | (h) | Ratio 1:3:6 | 100 Cft | 0.08 | 40827.38 | 3266.1904 | |
| 253 | **FLOORING** | ||||||
| 254 | 10-16 | Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick | 100 Sft | 21.4 | 16609.8 | 355449.72 | |
| 255 | **NON-SCHEDULED ITEM** | ||||||
| 256 | NSI-01 | Providing, supplying and fixing of MS STEEL Square Tube for Corner Columns 5 inch, (Triangular Shape) 10gauge Thick.Supply of MS STEEL Square Tube for Cross 4 inch x 4 inch x12 gauge Thick for Top Sections same as bottom section. Supply of MS STEEL Rectangular Tube for Mesh Frame 3 inch x 1.5 inch x 12 gauge Thick. Supply and Fixing of 2 inch x 2 inch x 8 gauge Wire Mesh Black Paint. Supply of Floodlight Column MS STEEL Square Tube 10 ft Long 3 inch x 1.5 inch 14 gauge Thick. Supply & fixing with complete accessories with 10 mm thick metal plates and fixtures. (Botts, Elastic Washers, Rubber Mats) etc.complete in all respects. | Sft. | 2178 | 1186 | 2583108 | |
| 257 | NSI-02 | Providing, supplying and fixing Ghani Glass12 mm thick Tempered glass with complete accessories etc.complete in all respects. | Sft. | 1261 | 1814 | 2287454 | |
| 258 | NSI-03 | Providing, supplying and fixing Bellin Turf Vietnam / CC Gras Color Blue, Green, TerracottaThickness 12 mm Backing: PU backing Material: PE Monofilament +PP texturized Yarn (Curly) Dtex: 9600 Also Include Installation of Silica Sand (2 tons) Waterproof Turf Cover complete in all respects. | Sft. | 2178 | 1084 | 2360952 | |
| 259 | NSI-04 | Providing, Supplying and fixing Paddle Net Length: 9830 mm, Height 920mm Material: PP, Thickness: 3mm Mesh: 43mm x 43mm Net Column 4 in x 4 in 12 gauge pole With pully and tightner Height: 920 mm Column Size: 80 mm x 80 mm x 3 mm Leather Poshish with branding (Complete Set) complete in all respects. | Set. | 1 | 221250 | 221250 | |
| 260 | NSI-05 | Providing, Supplying and fixing Digital Scoring Board | No | 1 | 73750 | 73750 | |
| 261 | NSI-06 | Providing and Supplying Rackets and Balls 2x Padel Rackets 12k 2x Containers and Padel balls Racket hanger complete in all respects. | No | 1 | 147500 | 147500 | |
| 262 | **BADMINTON** | ||||||
| 263 | **CIVIL WORKS** | ||||||
| 264 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 265 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 3.66 | 12266.7 | 44896.122 | |
| 266 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 2.01 | 8155.5 | 16392.555 | |
| 267 | ii) | ii) With new earth excavated from outside lead upto one chain (30 m). | 1000 Cft | 1.95 | 17545.5 | 34213.725 | |
| 268 | **CONCRETE** | ||||||
| 269 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 270 | (h) | Ratio 1:3:6 | 100 Cft | 0.26 | 40827.38 | 10615.1188 | |
| 271 | (i) | Ratio 1:4:8 | 100 Cft | 12.34 | 35592.28 | 439208.7352 | |
| 272 | 06-06 | Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.). | |||||
| 273 | a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects.including all lead and lift. | ||||||
| 274 | (2) Type B (nominal mix 1:1½: 3) | Per Cft | 3358 | 853.53 | 2866153.74 | ||
| 275 | (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift. | ||||||
| 276 | (2) Type B (nominal mix 1: 1½: 3) | Per Cft | 1152 | 700.58 | 807068.16 | ||
| 277 | 06-12 | Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars). | |||||
| 278 | (b) Deformed bars | ||||||
| 279 | ii) Grade-60 | 100kg | 148 | 28479.6 | 4214980.8 | ||
| 280 | **BRICK WORK** | ||||||
| 281 | 07-05 (i) | Pacca brick work in 1:4 C/S mortar in Ground floor | 100 Cft | 11.79 | 42181.95 | 497325.1905 | |
| 282 | **FLOORING** | ||||||
| 283 | 06-02 | Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge. | 100Cft | 7.72 | 14076.5 | 108670.58 | |
| 284 | 10-14 | Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm) | 100 Sft | 5.76 | 21668.65 | 124811.424 | |
| 285 | 10-48 | Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White | Per Sft | 114 | 2015.75 | 229795.5 | |
| 286 | 10-49 | Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. | Per Rft | 42 | 39.9 | 1675.8 | |
| 287 | 10-48 | Providing, laying and jointing Premium Quality Imported HDF Laminated Wooden Flooring (sustainable certification compliance )of approved color, shade, size and surface finish having properties of water resistance, UV resistance, stain resistance, scratch resistance, abrasion resistance complying EN 438, including the cost of edging & underlayment (min 2 mm polyethylene / EVA ), etc., complete in all respect as per approved specifications and as approved by the Engineer incharge. ii 12mm thick (AC5 - cycle>6000) | Per Sft | 1665 | 909.7 | 1514650.5 | |
| 288 | **SURFACE RENDERING** | ||||||
| 289 | 11-9(b) | Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick | 100 Sft | 18.98 | 4923.45 | 93447.081 | |
| 290 | 11-9(c) | Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick | 100 Sft | 19.54 | 6585.35 | 128677.739 | |
| 291 | **DOORS AND WINDOWS** | ||||||
| 292 | 12-64 | Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge | Each | 1 | 4569.55 | 4569.55 | |
| 293 | **PAINTING AND VARNISHING** | ||||||
| 294 | 13-5d | Preparing surface and painting guard bars, gates of iron bars, gratings, railing (including standards, braces, etc.) and in similar open work:- | |||||
| 295 | i). Priming coat | 100 Sft | 18.59 | 1274.1 | 23685.519 | ||
| 296 | ii). each subsequent coat of paint (2 coats) | 100 Sft | 37.18 | 850.6 | 31625.308 | ||
| 297 | 13-9 | Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m) | 100 Sft | 16.5 | 2821.7 | 46558.05 | |
| 298 | **IRON WORKS** | ||||||
| 299 | 25-10 | Fabrication of heavy steel work, with angle, tees, flat iron round iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, but excluding erection in position | 100 Kg | 56.24 | 35334.3 | 1987201.032 | |
| 300 | 25-11 | Erection and fitting in position iron trusses, staging of water tanks, etc. | 100 Kg | 56.24 | 2042.95 | 114895.508 | |
| 301 | 25-38 | Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer Incharge | Per Rft | 15 | 3387.45 | 50811.75 | |
| 302 | 25-69 | Providing and fixing 12 mm Tempered Glass Door frameless comprising of aluminium H-section (D48) at bottom, H-type S.S framless handles both side (approved), top pivot hinges, bottom concealed floor machine hinges, s.s patch fitting, D glass door lock (approved) and all the cost of using approved standard fittings, accessories etc., and hardware any required, as shown on drawings, complete in all respect as per Specifications,as approved by the Engineer. | Per Sft | 40 | 2184.75 | 87390 | |
| 303 | **MISCELLANEOUS** | ||||||
| 304 | 26-43 | Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge | Sft | 5919 | 12.7 | 75171.3 | |
| 305 | **NON SCHEDULE ITEMS** | ||||||
| 306 | **IRON WORKS** | ||||||
| 307 | NSI-01 | Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects. | Sft. | 385 | 110 | 42350 | |
| 308 | NSI-02 | Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects. | Sft. | 1665 | 1020 | 1698300 | |
| 309 | NSI-03 | Supplying and installation of sandwich roofing panels of 2" (50 mm) overall thickness, comprising outer sheet of 24 SWG pre-painted galvanized steel (PPGI) and inner sheet of 26 SWG PPGI, factory-bonded with rigid insulation core of PUF/PIR/EPS of density 40 ± 2 kg/m³, modular width approx. 1000 mm, lengths as per site requirement, with tongue-and-groove/cam-lock jointing system, complete with ridge, flashing, fasteners, sealants, and trims, ensuring thermal conductivity ≤ 0.024 W/make, sound insulation ≥ 25 dB, and fire resistance Class B or equivalent, including all cutting, fixing finishing and complete in all respects as per drawings and as directed by The Engineer’s instructions. | Sft. | 1859 | 1560 | 2900040 | |
| 310 | NSI-04 | Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer. | Sft. | 1 | 50000 | 50000 | |
| 311 | NSI-05 | Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area. | Sft | 977 | 440 | 429880 | |
| 312 | NSI-06 | Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects. | Sft | 977 | 2500 | 2442500 | |
| 313 | NSI-07 | Structural/glazing system with 2 mm thick and 100mm wide powder coated (in approved colour) base frame system as per the recommendations of the specialized facade designer and agreed by the approved manufacturer and stainless steel fittings using insulated glazing unit (IGU) system comprising of 6mm thick imported Low-E glass of approved color/shade having Low-E coating on surface no. 2 (inside the outer glass) and 6mm thick clear tempered glass (inner glass), with 12 mm wide aluminum spacers Low-E glass shall have a maximum of 3.7 U-factor with 0.45 solar heat gain coefficient. The glass to be used shall be from Pilkington/Guardian or an approved equivalent manufacturer. Doors in the curtain wall shall be of 12 mm thick Low-E tempered glass of approved color/shade, having handles 1500 mm long with 38mm dia & 2 mm wall thickness pipes of SS-316 brushed finish. All joints between the panels shall be sealed with minimum clear silicon sealant from Dow Corning of an approved equivalent. The Contractor shall submit shop drawings for the approval of the Engineer. | Sft | 841 | 3800 | 3195800 | |
| 314 | **BOX CRICKET /FUTSAL GROUND** | ||||||
| 315 | **CIVIL WORKS** | ||||||
| 316 | **EARTH WORK (EXCAVATION & EMBANKMENT)** | ||||||
| 317 | 03-21 | Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum | 1000 Cft | 0.1 | 12266.7 | 1226.67 | |
| 318 | 03-15 | Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc. | 1000 Cft | 0.06 | 8155.5 | 489.33 | |
| 319 | **CONCRETE** | ||||||
| 320 | 06-05 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 321 | (f) | Ratio 1:2:4 | 100 Cft | 15.08 | 47998.78 | 723821.6024 | |
| 322 | (h) | Ratio 1:3:6 | 100 Cft | 0.12 | 40827.38 | 4899.2856 | |
| 323 | **FLOORING** | ||||||
| 324 | 10-16 | Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick | 100 Sft | 42.64 | 16609.8 | 708241.872 | |
| 325 | **NON SCHEDULE ITEMS** | ||||||
| 326 | NSI-01 | Providing, supplying and fixing 3 inch round poles galvanized for vertical columns 12 gauge 22 ft height 2 inch round poles galvanized for horizontal connections 2 lines on after 10 ft height Ground fixing with J-bolt system 3 ft deep and 10 mm thick iron base plates Top net tension iron cable 9 mm etc.complete in all respects. | Sft. | 4264 | 676 | 2882464 | |
| 327 | NSI-02 | Providing, supplying and fixing Iron Mesh / Net Coverage Iron mesh with 2 inch holes on all four sides diamond shape Height 20 ft 10 guage UV coated fiber net on top Solid CNC designed gate etc.complete in all respects. | Sft. | 14500 | 87 | 1261500 | |
| 328 | NSI-03 | Providing, supplying and fixing Imported turf for cricket pitch Color: Blue, Green, Terracotta Pile height 12 mm PU backing PE Monofilament + PP texturized Yarn (Curly) Turf for Ground Multiparous Grass for futsal and cricket Color: Lite and Dark Green Pile height 30 mm 20 stiches UV coated complete in all respects. | Sft. | 4264 | 606 | 2583984 | |
| 329 | NSI-04 | Providing and Supplying Play Equipment 2 x Bats Set of Wickets 2 x Balls | No | 1 | 36875 | 36875 | |
| 330 | **INTERNAL ROADS** | ||||||
| 331 | **CIVIL WORKS** | ||||||
| 332 | 03-25/P-26 | Compaction of earthwork with power road roller, includingploughing, mixing, moistening earth to optimum moisture content in layers, etc. complete | |||||
| 333 | i) 95% to 100% maximum modified AASHTO dry density. | P.CUM | 385.448646336 | 60.05 | 23146.191212477 | ||
| 334 | 06-05/P-35 | Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift. | |||||
| 335 | (f) Ratio 1: 2: 4 | P.CUM | 192.724323168 | 16945.35 | 3265781.1095949 | ||
| 336 | 18-3 /P-106 | a) Providing and laying sub-base course of stone product of approved quality and grade, including placing, mixing, spreading and compaction of sub-base material to required depth, camber, grade to achieve 100% maximum modified AASHO dry density, including carriage of all material to site of work except gravel and. aggregate. i/c lead ii) Crushed stone aggregate. | P.CUM | 254.39610658176 | 3669.65 | 933544.67251776 | |
| 337 | 10-44/p-65 | Providing and laying Polygon Pavers, having 7000 PSI crushing strength of approved manufacturer, 60mm thick, over 2" to 3" sand cushion i/c grouting with sand in joints i/c finishing to require slope,in pattern as approved by Engineer Incharge. Complete in all respect. (Grey & Combination of any Colour) | Per Meter | 1264.9140148699 | 1873 | 2369183.9498513 | |
| 338 | **PLUMBING WORKS** | ||||||
| 339 | **BILLIARD ROOM** | ||||||
| 340 | **SANITARY FIXTURES AND FITTINGS** | ||||||
| 341 | 19 / 3 | Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 342 | B | One Piece | |||||
| 343 | iii. | PORTA HD 102N Toilet Cito with Hydraulic Seat Cover | Each | 2 | 59851.1 | 119702.2 | |
| 344 | 19 / 7 | Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc. | |||||
| 345 | (i) | white with pedestal | Each | 2 | 12051.55 | 24103.1 | |
| 346 | 19 / 16 | Providing and fixing, chromium plated soap dish. | Each | 2 | 981.6 | 1963.2 | |
| 347 | 19 / 9 / ii page 119 | Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steel | Each | 2 | 4229.4 | 8458.8 | |
| 348 | 19 / 18 | Providing and fixing, chromium plated toilet paper holder. | Each | 2 | 1271.45 | 2542.9 | |
| 349 | 19 / 19 / i | Providing and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") dia | Each | 2 | 1337.2 | 2674.4 | |
| 350 | 19 / 20 | Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality. | Each | 2 | 1546.2 | 3092.4 | |
| 351 | 19/21 | Providing and fixing glass shelf 60x13 cm (24"x5"), with 5mm thick glass:- i) with chromium plated brackets and railing. | Each | 2 | 1701.7 | 3403.4 | |
| 352 | 19 / 27/ ii | Providing and fixing chromium plated bib cock 1.5cm (1/2") | Each | 2 | 1588 | 3176 | |
| 353 | 19 / 28 | Providing and fixing chromium plated Tee stop cock 15mm (1/2") | Each | 10 | 2068 | 20680 | |
| 354 | 19 / 52 | Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge | |||||
| 355 | ii | Lever Type Basin Mixer | Each | 2 | 6707 | 13414 | |
| 356 | iii | Double Bib Cock | Each | 2 | 1907 | 3814 | |
| 357 | v | Muslim shower | Each | 2 | 2387 | 4774 | |
| 358 | viI | Bottle Trap | Each | 2 | 1487 | 2974 | |
| 359 | 19 / 7 / ii page 118 | Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) | Each | 10 | 712.8 | 7128 | |
| 360 | 19 / 55 page 117 | Providing/fixing Gas water heater (Geyser) of specified capacity, comprising of water tank made of 14 SWG steel sheet and cover with 20 SWG MS sheet, best quality make of Corona/Ambassador / Super Asia/Canon or approved equivalent manufacturer i/c the cost of non return valve,imported thermostate,G.I. accessories, safety valve and making connection with existing water supply pipe line complete in all respects as approved and directed by the Engineer Incharge | |||||
| 361 | (i) | 06 Gallons | Each | 2 | 19730.05 | 39460.1 | |
| 362 | **WATER SUPPLY PIPES AND FITTINGS** | ||||||
| 363 | 23 / 33 / b | Providing, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20 | |||||
| 364 | ii | 25mm dia | Rft | 100 | 99.7 | 9970 | |
| 365 | iii | 32mm dia | Rft | 50 | 158.25 | 7912.5 | |
| 366 | iv | 40mm dia | Rft | 20 | 241.75 | 4835 | |
| 367 | 23 / 42 | Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 368 | a-ii | 3/4" dia Brass Threaded Valves | Each | 1 | 3510 | 3510 | |
| 369 | a-iii | 1" dia Brass Threaded Valves | Each | 1 | 5025.6 | 5025.6 | |
| 370 | 23 / 45 | Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic | |||||
| 371 | a-ii | 3/4 inches | Each | 1 | 1896 | 1896 | |
| 372 | **SOIL, WASTE AND VENT PIPES & FITTINGS** | ||||||
| 373 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 374 | iii | 50mm | Rft | 20 | 103.95 | 2079 | |
| 375 | iv | 82mm | Rft | 50 | 160.6 | 8030 | |
| 376 | v | 110mm | Rft | 30 | 254.3 | 7629 | |
| 377 | vi | 160mm | Rft | 10 | 493.4 | 4934 | |
| 378 | 19 / 49 | Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 379 | b-i | Multi-Trap 4" | Each | 2 | 1436.1 | 2872.2 | |
| 380 | c-ii | Vent Cowel 3" | Each | 2 | 386.1 | 772.2 | |
| 381 | 19 / 12 page 119 | Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 382 | (i) | 4" Diameter | Each | 2 | 1254.95 | 2509.9 | |
| 383 | 21 / 5 | Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects: | |||||
| 384 | a) | with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type. | Each | 2 | 17212.95 | 34425.9 | |
| 385 | **STORM DRAINAGE PIPES & FITTINGS** | ||||||
| 386 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 387 | v | 110mm | Rft | 30 | 254.3 | 7629 | |
| 388 | 19 / 13 page 119 | Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 389 | (i) | 4" Diameter | Each | 2 | 1284.8 | 2569.6 | |
| 390 | **NON-SCHEDULED ITEMS** | ||||||
| 391 | **GENERAL NOTE ** | ||||||
| 392 | Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer. | ||||||
| 393 | NS-01 | CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects. | Each | 2 | 2170 | 4340 | |
| 394 | **PLUMBING WORKS** | ||||||
| 395 | **CAFÉ / CIGAR ROOM** | ||||||
| 396 | **SANITARY FIXTURES AND FITTINGS** | ||||||
| 397 | 19 / 3 | Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 398 | B | One Piece | |||||
| 399 | iii. | PORTA HD 102N Toilet Cito with Hydraulic Seat Cover | Each | 2 | 59851.1 | 119702.2 | |
| 400 | 19 / 7 | Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc. | |||||
| 401 | (i) | white with pedestal | Each | 2 | 12051.55 | 24103.1 | |
| 402 | 19 / 8 | Providing and fixing stainless steel sink with drain board, size 120x60 cm (48"x24") including bracket set, waste pipe and waste coupling. | Each | 2 | 15806.95 | 31613.9 | |
| 403 | 19 / 30 | Providing and fixing, chromium plated mixing valve, for wash hand basin, sink or shower. | Each | 2 | 3950 | 7900 | |
| 404 | 19 / 16 | Providing and fixing, chromium plated soap dish. | Each | 2 | 981.6 | 1963.2 | |
| 405 | 19 / 9 / ii page 119 | Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steel | Each | 2 | 4229.4 | 8458.8 | |
| 406 | 19 / 18 | Providing and fixing, chromium plated toilet paper holder. | Each | 2 | 1271.45 | 2542.9 | |
| 407 | 19 / 19 / i | Providing and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") dia | Each | 2 | 1337.2 | 2674.4 | |
| 408 | 19 / 20 | Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality. | Each | 2 | 1546.2 | 3092.4 | |
| 409 | 19/21 | Providing and fixing glass shelf 60x13 cm (24"x5"), with 5mm thick glass:- i) with chromium plated brackets and railing. | Each | 2 | 1701.7 | 3403.4 | |
| 410 | 19 / 27/ ii | Providing and fixing chromium plated bib cock 1.5cm (1/2") | Each | 2 | 1588 | 3176 | |
| 411 | 19 / 28 | Providing and fixing chromium plated Tee stop cock 15mm (1/2") | Each | 8 | 2068 | 16544 | |
| 412 | 19 / 52 | Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge | |||||
| 413 | ii | Lever Type Basin Mixer | Each | 2 | 6707 | 13414 | |
| 414 | iii | Double Bib Cock | Each | 2 | 1907 | 3814 | |
| 415 | v | Muslim shower | Each | 2 | 2387 | 4774 | |
| 416 | viI | Bottle Trap | Each | 2 | 1487 | 2974 | |
| 417 | 19 / 7 / ii page 118 | Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) | Each | 8 | 712.8 | 5702.4 | |
| 418 | 19 / 56 page 117 | Supply & Installation of Duel (Electric and Gas Water Heaters) with factory-installed pressure relief valve, adjustable water temperature control thermostate, Copper connections for specific capacity having leaving waterr temprature 140 deg F & working pressure 15 PSI, Ambasador/Canon or approved manufacturer i/c cost of all accessories to complete the job as per specifications and standards & making connection, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 419 | ii | 55 Gallons | Each | 1 | 83161.5 | 83161.5 | |
| 420 | **WATER SUPPLY PIPES AND FITTINGS** | ||||||
| 421 | 23 / 33 / b | Providing, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20 | |||||
| 422 | ii | 25mm dia | Rft | 200 | 99.7 | 19940 | |
| 423 | iii | 32mm dia | Rft | 50 | 158.25 | 7912.5 | |
| 424 | iv | 40mm dia | Rft | 30 | 241.75 | 7252.5 | |
| 425 | v | 50mm dia | Rft | 10 | 347.1 | 3471 | |
| 426 | vi | 63mm dia | Rft | 50 | 541.3 | 27065 | |
| 427 | 23 / 42 | Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 428 | a-ii | 3/4" dia Brass Threaded Valves | Each | 6 | 3510 | 21060 | |
| 429 | a-iii | 1" dia Brass Threaded Valves | Each | 4 | 5025.6 | 20102.4 | |
| 430 | a-iv | 1-1/4" dia Brass Threaded Valves | Each | 1 | 7039.2 | 7039.2 | |
| 431 | a-v | 1-1/2" dia Brass Threaded Valves | Each | 4 | 9930 | 39720 | |
| 432 | a-vi | 2" dia Brass Threaded Valves | Each | 1 | 14500.8 | 14500.8 | |
| 433 | 23 / 45 | Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic | |||||
| 434 | a-ii | 3/4 inches | Each | 2 | 1896 | 3792 | |
| 435 | 19 / 12 page 118 | Providing and fixing brass ball float valve: | |||||
| 436 | v | 4.0 cm (1½") dia | Each | 1 | 1934 | 1934 | |
| 437 | **SOIL, WASTE AND VENT PIPES & FITTINGS** | ||||||
| 438 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 439 | iii | 50mm | Rft | 50 | 103.95 | 5197.5 | |
| 440 | iv | 82mm | Rft | 100 | 160.6 | 16060 | |
| 441 | v | 110mm | Rft | 80 | 254.3 | 20344 | |
| 442 | vi | 160mm | Rft | 10 | 493.4 | 4934 | |
| 443 | 19 / 49 | Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 444 | b-i | Multi-Trap 4" | Each | 4 | 1436.1 | 5744.4 | |
| 445 | c-ii | Vent Cowel 3" | Each | 2 | 386.1 | 772.2 | |
| 446 | 19 / 12 page 119 | Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 447 | (i) | 4" Diameter | Each | 2 | 1254.95 | 2509.9 | |
| 448 | 21 / 5 | Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects: | |||||
| 449 | a) | with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type. | Each | 3 | 17212.95 | 51638.85 | |
| 450 | **STORM DRAINAGE PIPES & FITTINGS** | ||||||
| 451 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 452 | v | 110mm | Rft | 65 | 254.3 | 16529.5 | |
| 453 | 19 / 13 page 119 | Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 454 | (i) | 4" Diameter | Each | 3 | 1284.8 | 3854.4 | |
| 455 | **MISCELLANEOUS** | ||||||
| 456 | 19 / 40 | Supply and fitting of cast iron manhole cover square with frame, etc. complete | |||||
| 457 | iii) | 60cm x 60cm(24"x24") | Each | 2 | 6089.85 | 12179.7 | |
| 458 | **NON-SCHEDULED ITEMS** | ||||||
| 459 | **GENERAL NOTE ** | ||||||
| 460 | Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer. | ||||||
| 461 | **SANITARY FIXTURES AND FITTINGS** | ||||||
| 462 | NS-01 | CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects. | Each | 2 | 2170 | 4340 | |
| 463 | NS-02 | Electric water coolers of 40Gallons capacity, minimum two taps, including Tee stop cock on inlet, and all other accessories for complete installation. | Each. | 1 | 121000 | 121000 | |
| 464 | NS-03 | Triple water filter (10") including inlet and outlet connections, power supply, and all accessories for complete installation | Each. | 1 | 32450 | 32450 | |
| 465 | **WATER SUPPLY PIPES AND FITTINGS** | ||||||
| 466 | G.I. water pipes conforming to BS-1387, Medium Grade, I/c all fittings, wraping polythene tape, giving anticorrosion treatment, applying protective painting, clamps, hangers & supports, making holes in concrete or masonry and then repairing holes, flushing, disinfecting, testing and commissioning etc. of approved make, of the following diameters,complete in all respects. | ||||||
| 467 | NS-04 | 3/4 inch | Rft | 20 | 515 | 10300 | |
| 468 | NS-05 | 1 inch | Rft | 10 | 755 | 7550 | |
| 469 | NS-06 | 1-1/4 inches | Rft | 10 | 825 | 8250 | |
| 470 | NS-07 | 1-1/2 inches | Rft | 100 | 950 | 95000 | |
| 471 | NS-08 | 2 inches | Rft | 10 | 1270 | 12700 | |
| 472 | **MISCELLANEOUS** | ||||||
| 473 | NS-09 | 3/4" diameter Galvanised MS ladder rungs for water tanks; each rung of 18" width, 6" projected outside the wall and 6" embeded in RCC on both ends; including all necessary works for complete installation. | Each | 10 | 1490 | 14900 | |
| 474 | NS-10 | Dia 2" u-turned G.I. vent pipes, pudddle plate, with insect proof mesh at open end etc., complete in all respects. | Job | 1 | 7545 | 7545 | |
| 475 | **PLUMBING WORKS** | ||||||
| 476 | **SWIMMING POOL** | ||||||
| 477 | **SANITARY FIXTURES AND FITTINGS** | ||||||
| 478 | 19 / 3 | Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 479 | B | One Piece | |||||
| 480 | iii. | PORTA HD 102N Toilet Cito with Hydraulic Seat Cover | Each | 1 | 59851.1 | 59851.1 | |
| 481 | 19 / 5 | Providing and fitting white glazed earthen ware water closet, squartter type, with separate foot rest. | Each | 1 | 8761.75 | 8761.75 | |
| 482 | 19 / 13 / i | Providing and fitting plastic made low down flushing cistern 13.63 litre (3 gallons) capacity, including bracket set, copper connection, etc. complete , white | Each | 1 | 5803.2 | 5803.2 | |
| 483 | 19/49 | Providing, fixing, testing and commissioning of μ-PVC (Unplasticized polyvinyl Chloride ) Nikasi/ waste pipe Fittings make of Dadex /Popular/Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 484 | a) | P-Trap | |||||
| 485 | (i) 4" dia | Each | 1 | 960.2 | 960.2 | ||
| 486 | 19 / 4 / ii page 118 | Providing and fixing, flushing bend of PVC , 4cm (1-1/2") | Each | 1 | 394.65 | 394.65 | |
| 487 | 19 / 7 | Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc. | |||||
| 488 | (v) | Under Counter Vanity Basin | Each | 5 | 13047.55 | 65237.75 | |
| 489 | 19 / 16 | Providing and fixing, chromium plated soap dish. | Each | 5 | 981.6 | 4908 | |
| 490 | 19 / 9 / ii page 119 | Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steel | Each | 2 | 4229.4 | 8458.8 | |
| 491 | 19 / 18 | Providing and fixing, chromium plated toilet paper holder. | Each | 1 | 1271.45 | 1271.45 | |
| 492 | 19 / 19 / i | Providing and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") dia | Each | 2 | 1337.2 | 2674.4 | |
| 493 | 19 / 20 | Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality. | Each | 5 | 1546.2 | 7731 | |
| 494 | 19 / 27/ ii | Providing and fixing chromium plated bib cock 1.5cm (1/2") | Each | 2 | 1588 | 3176 | |
| 495 | 19 / 28 | Providing and fixing chromium plated Tee stop cock 15mm (1/2") | Each | 12 | 2068 | 24816 | |
| 496 | 19 / 52 | Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge | |||||
| 497 | ii | Lever Type Basin Mixer | Each | 5 | 6707 | 33535 | |
| 498 | iii | Double Bib Cock | Each | 2 | 1907 | 3814 | |
| 499 | iv | Open Type Wall Shower | Each | 2 | 18707 | 37414 | |
| 500 | v | Muslim shower | Each | 2 | 2387 | 4774 | |
| 501 | viI | Bottle Trap | Each | 5 | 1487 | 7435 | |
| 502 | 19 / 7 / ii page 118 | Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) | Each | 12 | 712.8 | 8553.6 | |
| 503 | 19 / 56 page 117 | Supply & Installation of Duel (Electric and Gas Water Heaters) with factory-installed pressure relief valve, adjustable water temperature control thermostate, Copper connections for specific capacity having leaving waterr temprature 140 deg F & working pressure 15 PSI, Ambasador/Canon or approved manufacturer i/c cost of all accessories to complete the job as per specifications and standards & making connection, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 504 | ii | 55 Gallons | Each | 1 | 83161.5 | 83161.5 | |
| 505 | **WATER SUPPLY PIPES AND FITTINGS** | ||||||
| 506 | 23 / 33 / b | Providing, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20 | |||||
| 507 | ii | 25mm dia | Rft | 100 | 99.7 | 9970 | |
| 508 | iii | 32mm dia | Rft | 60 | 158.25 | 9495 | |
| 509 | iv | 40mm dia | Rft | 20 | 241.75 | 4835 | |
| 510 | v | 50mm dia | Rft | 50 | 347.1 | 17355 | |
| 511 | vi | 63mm dia | Rft | 10 | 541.3 | 5413 | |
| 512 | 23 / 42 | Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 513 | a-ii | 3/4" dia Brass Threaded Valves | Each | 2 | 3510 | 7020 | |
| 514 | a-iii | 1" dia Brass Threaded Valves | Each | 2 | 5025.6 | 10051.2 | |
| 515 | a-iv | 1-1/4" dia Brass Threaded Valves | Each | 1 | 7039.2 | 7039.2 | |
| 516 | a-v | 1-1/2" dia Brass Threaded Valves | Each | 1 | 9930 | 9930 | |
| 517 | a-vi | 2" dia Brass Threaded Valves | Each | 1 | 14500.8 | 14500.8 | |
| 518 | 23 / 45 | Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic | |||||
| 519 | a-ii | 3/4 inches | Each | 2 | 1896 | 3792 | |
| 520 | **SOIL, WASTE AND VENT PIPES & FITTINGS** | ||||||
| 521 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 522 | iii | 50mm | Rft | 50 | 103.95 | 5197.5 | |
| 523 | iv | 82mm | Rft | 100 | 160.6 | 16060 | |
| 524 | v | 110mm | Rft | 50 | 254.3 | 12715 | |
| 525 | vi | 160mm | Rft | 10 | 493.4 | 4934 | |
| 526 | 19 / 49 | Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge. | |||||
| 527 | b-i | Multi-Trap 4" | Each | 2 | 1436.1 | 2872.2 | |
| 528 | c-ii | Vent Cowel 3" | Each | 2 | 386.1 | 772.2 | |
| 529 | 19 / 12 page 119 | Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 530 | (i) | 4" Diameter | Each | 6 | 1254.95 | 7529.7 | |
| 531 | 21 / 5 | Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects: | |||||
| 532 | a) | with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type. | Each | 2 | 17212.95 | 34425.9 | |
| 533 | **STORM DRAINAGE PIPES & FITTINGS** | ||||||
| 534 | 19 / 47 | Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge. | |||||
| 535 | v | 110mm | Rft | 65 | 254.3 | 16529.5 | |
| 536 | 19 / 13 page 119 | Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 537 | (i) | 4" Diameter | Each | 3 | 1284.8 | 3854.4 | |
| 538 | **MISCELLANEOUS** | ||||||
| 539 | 19 / 40 | Supply and fitting of cast iron manhole cover square with frame, etc. complete | |||||
| 540 | iii) | 60cm x 60cm(24"x24") | Each | 1 | 6089.85 | 6089.85 | |
| 541 | **NON-SCHEDULED ITEMS** | ||||||
| 542 | **GENERAL NOTE ** | ||||||
| 543 | Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer. | ||||||
| 544 | **SANITARY FIXTURES AND FITTINGS** | ||||||
| 545 | NS-01 | CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects. | Each | 10 | 2170 | 21700 | |
| 546 | NS-02 | Electric water coolers of 40Gallons capacity, minimum two taps, including Tee stop cock on inlet, and all other accessories for complete installation. | Each. | 1 | 121000 | 121000 | |
| 547 | NS-03 | Triple water filter (10") including inlet and outlet connections, power supply, and all accessories for complete installation | Each. | 1 | 32450 | 32450 | |
| 548 | **SOIL, WASTE AND VENT PIPES & FITTINGS** | ||||||
| 549 | G.I. water pipes conforming to BS-1387, Medium Grade, I/c all fittings, wraping polythene tape, giving anticorrosion treatment, applying protective painting, clamps, hangers & supports, making holes in concrete or masonry and then repairing holes, flushing, disinfecting, testing and commissioning etc. of approved make, of the following diameters,complete in all respects. | ||||||
| 550 | NS-04 | 2 inches | Rft | 50 | 1270 | 63500 | |
| 551 | uPVC floor Cleanout of the following diameter, including screw type Stainless Steel/CP top tile access plug, transition pipe, breaking concrete or masonry work & then making it good, etc. complete in all respects. | ||||||
| 552 | NS-06 | 3 inches | Each | 2 | 7765 | 15530 | |
| 553 | NS-07 | 4 inches | Each | 1 | 8635 | 8635 | |
| 554 | **MISCELLANEOUS** | ||||||
| 555 | NS-07 | 3/4" diameter Galvanised MS ladder rungs for water tanks; each rung of 18" width, 6" projected outside the wall and 6" embeded in RCC on both ends; including all necessary works for complete installation. | Each | 5 | 1490 | 7450 | |
| 556 | **SWIMMING POOL EQUIPMENT** | ||||||
| 557 | NS-09 | Swimming pool related all plumbing works including all equipment, pumps, filters,heater, valves,skimmers, piping, fittings, nozzles, drains etc for a tentative pool size as 20'x40'x5' (30,000gallons) and all other works complete. | Job | 1 | 3600000 | 3600000 | |
| 558 | **RECEPTION/BILLIARD/TABLE-TENNIS** | ||||||
| 559 | **ELECTRICAL WORKS** | ||||||
| 560 | **Conduits & Pipes** | ||||||
| 561 | 46105 | Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials. | |||||
| 562 | ii | 20 mm i/d | Rft. | 4000 | 119.35 | 477400 | |
| 563 | iii | 25 mm i/d | Rft. | 4000 | 138.95 | 555800 | |
| 564 | vi) | 50 mm i/d | Rft. | 500 | 238.15 | 119075 | |
| 565 | vii) | 80 mm i/d | Rft. | 250 | 299.65 | 74912.5 | |
| 566 | viii) | 100 mm i/d | Rft. | 800 | 377.65 | 302120 | |
| 567 | 24-105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge | |||||
| 568 | **a)** | One way Gange Switch (Small) | |||||
| 569 | (i) | 01 Gange | Each | 3 | 463.2 | 1389.6 | |
| 570 | (ii) | 02 Gange | Each | 5 | 704.4 | 3522 | |
| 571 | (iii) | Three pin Light Plug 10/13 Amp | Each | 22 | 754.45 | 16597.9 | |
| 572 | (iv) | Telephone / TV/Datacable socket | Each | 10 | 662.45 | 6624.5 | |
| 573 | (v) | Fan Dimmer | Each | 1 | 740.6 | 740.6 | |
| 574 | (vi) | Bell push | Each | 1 | 598.2 | 598.2 | |
| 575 | (vii) | Three Pin Power Plug 15-32 Amp | Each | 8 | 924.55 | 7396.4 | |
| 576 | **b)** | One way Gange Switch (Large) | |||||
| 577 | (i) | 04 Gange | Each | 4 | 981.25 | 3925 | |
| 578 | (ii) | 05 Gange | Each | 4 | 1151.35 | 4605.4 | |
| 579 | (iii) | 06 Gange | Each | 4 | 1405.85 | 5623.4 | |
| 580 | **C)** | Two way Gange Switch Small | |||||
| 581 | (i) | 01 Gange One Way/ Two Way | Each | 3 | 499.9 | 1499.7 | |
| 582 | **Wiring** | ||||||
| 583 | 24-8 | Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 584 | c) | 450/750 volts, PVC insulated: | |||||
| 585 | ii) | 1.5 mm sq (3/0.029") | Per Rft. | 7000 | 42.4 | 296800 | |
| 586 | iii) | 2.5 mm sq (7/0.029") | Per Rft. | 3500 | 62 | 217000 | |
| 587 | iv) | 4 mm sq (7/0.036") | Per Rft. | 3000 | 81.85 | 245550 | |
| 588 | **LT Cables** | ||||||
| 589 | 24-10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | |||||
| 590 | i) | 4 mm sq (7/0.036") | Per Rft. | 50 | 74.65 | 3732.5 | |
| 591 | ii) | 6 mm sq (7/0.044") | Per Rft. | 10 | 100.45 | 1004.5 | |
| 592 | iii) | 10 mm sq (7/0.052") | Per Rft. | 250 | 155.7 | 38925 | |
| 593 | iv) | 16 mm sq (7/0.064") | Per Rft. | 50 | 234.3 | 11715 | |
| 594 | 24-11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- | |||||
| 595 | c) | PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:- | |||||
| 596 | iv) | 4 mm sq (7/0.036") | Per Rft. | 250 | 268.75 | 67187.5 | |
| 597 | v) | 6 mm sq (7/0.044") | Per Rft. | 20 | 381.4 | 7628 | |
| 598 | vi) | 10 mm sq (7/0.052") | Per Rft. | 150 | 605.85 | 90877.5 | |
| 599 | vii) | 16 mm sq (7/0.064") | Per Rft. | 150 | 926.05 | 138907.5 | |
| 600 | viii) | 25 mm sq (19/0.052") | Per Rft. | 20 | 1426.2 | 28524 | |
| 601 | ix) | 35 mm sq (19/0.064") | Per Rft. | 150 | 1919.9 | 287985 | |
| 602 | **Fans and Exhaust Fans** | ||||||
| 603 | 24-102 | Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. | |||||
| 604 | a)-i | Plastic body - 10" dia | Each | 2 | 5235.5 | 10471 | |
| 605 | a)-ii | Plastic body - 12" dia | Each | 1 | 5685.5 | 5685.5 | |
| 606 | **b) ** | **Steel body** | |||||
| 607 | i | 12" sweep | Each | 1 | 5516.75 | 5516.75 | |
| 608 | ii | 18" sweep | Each | 6641.75 | |||
| 609 | 24-103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 610 | ii) | 24" Sweep dia | Each | 4 | 10703 | 42812 | |
| 611 | 24-104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 612 | (iii) | 56" dia | Each | 1 | 10180.2 | 10180.2 | |
| 613 | **Lightning Protection System** | ||||||
| 614 | 24-111 | Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing) | P.Job | 2 | 21210.95 | 42421.9 | |
| 615 | 24-113 | Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System | |||||
| 616 | viii) | 70 mm² CU bare conductor | Per Rft | 200 | 850.45 | 170090 | |
| 617 | **CCTV** | ||||||
| 618 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 619 | a) | UTP (Unshielded Twisted pair) | |||||
| 620 | (i) | CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet system | Per Rft | 1200 | 49.2 | 59040 | |
| 621 | 24-126 | Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | |||||
| 622 | ii) | 16-Channel | Each | 1 | 116388.7 | 116388.7 | |
| 623 | 24-127 | Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge | |||||
| 624 | iii) | 10 TB | Each | 1 | 69360 | 69360 | |
| 625 | 24-128 | Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2 x 1Gigabit SFP ports with 2 x 1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP nooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/ Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge. | Each | 1 | 364102.5 | 364102.5 | |
| 626 | 24-132 | Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 627 | b | 4 Mega PixeL | |||||
| 628 | (i) | Fixed Bullet Type | Each | 1 | 71535 | 71535 | |
| 629 | (ii) | Fixed Dome type | Each | 5 | 82785 | 413925 | |
| 630 | 24-139 | Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge | |||||
| 631 | ii | 15U size (600x550x770 mm | Each | 1 | 59379.95 | 59379.95 | |
| 632 | 24-138 | Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge. | Each | 1 | 641053.15 | 641053.15 | |
| 633 | **DATA NETWORK & WIFI SYSTEM** | ||||||
| 634 | **Data Cabling System** | ||||||
| 635 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge. | |||||
| 636 | a-ii) | UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher) | P.Rft | 1500 | 69.6 | 104400 | |
| 637 | 24-119 | Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge. | |||||
| 638 | i) | 1 meter Patch Cord | Each | 8 | 1074.4 | 8595.2 | |
| 639 | ii) | 3 meter Patch Cord | Each | 8 | 1309.6 | 10476.8 | |
| 640 | 24-124 | Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | Each | 1 | 4108.8 | 4108.8 | |
| 641 | 24-125 | Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge. | |||||
| 642 | ii) | CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit) | Each | 1 | 35405 | 35405 | |
| 643 | 24-141 | Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project. | |||||
| 644 | i) | Single I/O | Each | 8 | 1678.15 | 13425.2 | |
| 645 | ii) | Double I/O | Each | 2626.5 | |||
| 646 | 24-142 | Supply, Installation and commissioning of Core Switches with interface : 10 GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 647 | i) | 24 Ports | Each | 1 | 125582.25 | 125582.25 | |
| 648 | 14324- | Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 649 | 24 Ports | Each | 1 | 91902 | 91902 | ||
| 650 | 24-144 | Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge. | |||||
| 651 | a-(ii) | 06 Core | PER RFT | 250 | 596.4 | 149100 | |
| 652 | 24-145 | Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge | |||||
| 653 | a) | Multimode (MM) Ports | |||||
| 654 | (ii) | 12 Ports | Each | 1 | 64560.4 | 64560.4 | |
| 655 | 24-160 | Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge. | |||||
| 656 | b) Column Type Speaker | ||||||
| 657 | (iv) | 60 Watt | Each | 4 | 80081.25 | 320325 | |
| 658 | 24-162 | Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge. | |||||
| 659 | vi) | 480 Watt | Each | 1 | 468983.65 | 468983.65 | |
| 660 | 24-165 | Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge | |||||
| 661 | i) | Cordless Microphone with Transmitter | Each | 1 | 151462.9 | 151462.9 | |
| 662 | 24-166 | Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer Incharge | Each | 1 | 116294.25 | 116294.25 | |
| 663 | 24-15 | Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 664 | a)-i | Flexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029") | Per Rft | 500 | 128.45 | 64225 | |
| 665 | 24-85 | Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge | |||||
| 666 | a) | Single Pole | |||||
| 667 | (iii) | 6-63 Amp (10 KA) | Each | 40 | 1459.05 | 58362 | |
| 668 | b) | Double Pole | |||||
| 669 | iii) 6-63 Amp (10 KA) | Each | 1 | 5621.55 | 5621.55 | ||
| 670 | 24-86 | Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge | |||||
| 671 | a) | Triple Pole | |||||
| 672 | (iii) | 15-100 Amp(18 KA) | Each | 12 | 12172.95 | 146075.4 | |
| 673 | viii) | 125-150 Amp(36 KA) | Each | 3 | 26516.7 | 79550.1 | |
| 674 | 24-90 | (Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately). | |||||
| 675 | (a) | 6" deep | |||||
| 676 | (i) | 20~60A | P.CFT | 30 | 2463.7 | 73911 | |
| 677 | ii) | 75~100A | P.CFT | 20 | 2604.4 | 52088 | |
| 678 | (b) | 12" deep | |||||
| 679 | (i) | 125~150A | P.CFT | 20 | 7011.65 | 140233 | |
| 680 | 24-91 | P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately). | |||||
| 681 | 1 | LT Switchboards | |||||
| 682 | a)(i) | 2.50 Ft deep 250~600A | P. cft | 20 | 4772.65 | 95453 | |
| 683 | 24-94 | Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge | |||||
| 684 | i) | Selector Switch | Each | 1 | 1228.8 | 1228.8 | |
| 685 | (ii) | Current Transformer Coil (Make: Metelx/Fico) | Each | 6 | 2134.3 | 12805.8 | |
| 686 | (iii) | Digital Voltmeter (0-600 Volt) | Each | 6 | 1012.8 | 6076.8 | |
| 687 | (iv) | Digital Ammeter (0-9999 Amp) | Each | 6 | 1228.8 | 7372.8 | |
| 688 | (v) | LED Phase Indicator | Each | 9 | 622.8 | 5605.2 | |
| 689 | (vi) | Push Button ON/OFF (Make: Schneider/Himal/Eqv.) | Each | 6 | 631.15 | 3786.9 | |
| 690 | vii) | Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB) | Each | 6 | 5373.8 | 32242.8 | |
| 691 | viii) | Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB) | Each | 9 | 1375.8 | 12382.2 | |
| 692 | ix) | Surge Suppressors | Each | 6 | 1060.8 | 6364.8 | |
| 693 | x) | Auto/Manual Switch 3-Steps (Make: GGT/Camsco) | Each | 1 | 2257.8 | 2257.8 | |
| 694 | xi) | Exhaust Fan with Louvers (Make: Imported/Plastim | Each | 3 | 3832.8 | 11498.4 | |
| 695 | xii) | Temperature Regulator 0~60C | Each | 3 | 2134.3 | 6402.9 | |
| 696 | xiii) | (Power Capacitors | Each | ||||
| 697 | a) | 12.5 KVAR | Each | 1 | 16852.8 | 16852.8 | |
| 698 | b) | 25 KVAR | Each | 1 | 25852.8 | 25852.8 | |
| 699 | Magnetic Contactor | ||||||
| 700 | (a) | 25 A (AC 3) for 12.5 KVAR | Each | 3 | 10048.8 | 30146.4 | |
| 701 | b) | 40 A (AC 3) for 25 KVAR | Each | 3 | 14332.8 | 42998.4 | |
| 702 | (xvii) | Power Factor Controller | |||||
| 703 | a) | 6 Steps | Each | 1 | 55252.8 | 55252.8 | |
| 704 | **Non - Schedule Items** | ||||||
| 705 | **Light Fixtures** | ||||||
| 706 | Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. **Note:** Refer light fixtures drawings/Schedule for complete light fixtures details. | ||||||
| 707 | NS-01 | 40 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects. | No. | 2 | 9500 | 19000 | |
| 708 | NS-02 | (16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects. | No. | 6 | 2500 | 15000 | |
| 710 | NS-03 | 15-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 60 | 3500 | 210000 | |
| 711 | NS-04 | 7-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 5 | 1950 | 9750 | |
| 712 | NS-05 | Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better rated | No. | 8 | 6500 | 52000 | |
| 713 | NS-06 | LED EXIT LIGHT 8/10 W | No. | 5 | 9500 | 47500 | |
| 714 | Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding, fittings insulation,tape wraping etc, insulation, refrigerant charge thermostate, control between indoor and outdoor units power wiring, conduiting, dura duct / channel mounting brackets and accessories complete in all respect. | ||||||
| 715 | NS-07 | Split Air- Conditioner 1.5 ton | Job | 4 | 350000 | 1400000 | |
| 716 | NS-08 | Floor standing type Air- Conditioner 4 ton | Job | 4 | 1200000 | 4800000 | |
| 717 | **CAFE/CIGAR ROOM (GF + FF)** | ||||||
| 718 | **ELECTRICAL WORKS** | ||||||
| 719 | **Conduits & Pipes** | ||||||
| 720 | 24-3 | Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials. | |||||
| 721 | ii | 20 mm i/d | Rft. | 8000 | 119.35 | 954800 | |
| 722 | iii | 25 mm i/d | Rft. | 10000 | 138.95 | 1389500 | |
| 723 | vi) | 50 mm i/d | Rft. | 2000 | 238.15 | 476300 | |
| 724 | vii) | 80 mm i/d | Rft. | 500 | 299.65 | 149825 | |
| 725 | viii) | 100 mm i/d | Rft. | 1000 | 377.65 | 377650 | |
| 726 | 24-105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made ofLegrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge | |||||
| 727 | a) | One way Gange Switch (Small) | |||||
| 728 | (i) | 01 Gange | Each | 5 | 463.2 | 2316 | |
| 729 | (ii) | 02 Gange | Each | 10 | 704.4 | 7044 | |
| 730 | (iii) | Three pin Light Plug 10/13 Amp | Each | 50 | 754.45 | 37722.5 | |
| 731 | (iv) | Telephone / TV/Datacable socket | Each | 15 | 662.45 | 9936.75 | |
| 732 | (v) | Fan Dimmer | Each | 1 | 740.6 | 740.6 | |
| 733 | (vi) | Bell push | Each | 1 | 598.2 | 598.2 | |
| 734 | (vii) | Three Pin Power Plug 15-32 Amp | Each | 10 | 924.55 | 9245.5 | |
| 735 | b) | One way Gange Switch (Large) | |||||
| 736 | (i) | 04 Gange | Each | 6 | 981.25 | 5887.5 | |
| 737 | (ii) | 05 Gange | Each | 6 | 1151.35 | 6908.1 | |
| 738 | (iii) | 06 Gange | Each | 6 | 1405.85 | 8435.1 | |
| 739 | C) | Two way Gange Switch Small | |||||
| 740 | (i) | 01 Gange One Way/ Two Way | Each | 4 | 499.9 | 1999.6 | |
| 741 | **WIRING** | ||||||
| 742 | 24-8 | Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 743 | c) | 450/750 volts, PVC insulated: | |||||
| 744 | ii) | 1.5 mm sq (3/0.029") | Per Rft. | 15000 | 42.4 | 636000 | |
| 745 | iii) | 2.5 mm sq (7/0.029") | Per Rft. | 5500 | 62 | 341000 | |
| 746 | iv) | 4 mm sq (7/0.036") | Per Rft. | 4000 | 81.85 | 327400 | |
| 747 | **LT CABLES** | ||||||
| 748 | 24-10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | |||||
| 749 | i) | 4 mm sq (7/0.036") | Per Rft. | 50 | 74.65 | 3732.5 | |
| 750 | ii) | 6 mm sq (7/0.044") | Per Rft. | 10 | 100.45 | 1004.5 | |
| 751 | iii) | 10 mm sq (7/0.052") | Per Rft. | 500 | 155.7 | 77850 | |
| 752 | iv) | 16 mm sq (7/0.064") | Per Rft. | 50 | 234.3 | 11715 | |
| 753 | viii) | 70 mm sq (19/0.083") | Per Rft. | 250 | 917.85 | 229462.5 | |
| 754 | 24-11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- | |||||
| 755 | c) | PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:- | |||||
| 756 | iv) | 4 mm sq (7/0.036") | Per Rft. | 500 | 268.75 | 134375 | |
| 757 | v) | 6 mm sq (7/0.044") | Per Rft. | 250 | 381.4 | 95350 | |
| 758 | vi) | 10 mm sq (7/0.052") | Per Rft. | 300 | 605.85 | 181755 | |
| 759 | vii) | 16 mm sq (7/0.064") | Per Rft. | 300 | 926.05 | 277815 | |
| 760 | viii) | 25 mm sq (19/0.052") | Per Rft. | 50 | 1426.2 | 71310 | |
| 761 | ix) | 35 mm sq (19/0.064") | Per Rft. | 300 | 1919.9 | 575970 | |
| 762 | **Fans and Exhaust Fans** | ||||||
| 763 | 24-102 | Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. | |||||
| 764 | a)-i | Plastic body - 10" dia | Each | 3 | 5235.5 | 15706.5 | |
| 765 | a)-ii | Plastic body - 12" dia | Each | 2 | 5685.5 | 11371 | |
| 766 | b) Steel body | ||||||
| 767 | i | 12" sweep | Each | 1 | 5516.75 | 5516.75 | |
| 768 | ii | 18" sweep | Each | 1 | 6641.75 | 6641.75 | |
| 769 | 24-103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 770 | ii) | 24" Sweep dia | Each | 10 | 10703 | 107030 | |
| 771 | 24-104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 772 | (iii) | 56" dia | Each | 1 | 10180.2 | 10180.2 | |
| 773 | **Lightning Protection System** | ||||||
| 774 | 24-111 | Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing) | P.Job | 5 | 21210.95 | 106054.75 | |
| 775 | 24-113 | Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System | |||||
| 776 | viii) | 70 mm² CU bare conductor | Per Rft | 225 | 850.45 | 191351.25 | |
| 777 | **CCTV** | ||||||
| 778 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 779 | a) | UTP (Unshielded Twisted pair) | |||||
| 780 | (i) | CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet system | Per Rft | 3000 | 49.2 | 147600 | |
| 781 | 24-126 | Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | |||||
| 782 | ii) | 16-Channel | Each | 1 | 116388.7 | 116388.7 | |
| 783 | 24-127 | Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge | |||||
| 784 | iii) | 10 TB | Each | 1 | 69360 | 69360 | |
| 785 | 24-128 | Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge. | Each | 1 | 364102.5 | 364102.5 | |
| 786 | 24-132 | Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 787 | b | 4 Mega PixeL | |||||
| 788 | (i) | Fixed Bullet Type | Each | 2 | 71535 | 143070 | |
| 789 | (ii) | Fixed Dome type | Each | 6 | 82785 | 496710 | |
| 790 | 24-139 | Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge | |||||
| 791 | ii | 15U size (600x550x770 mm | Each | 1 | 59379.95 | 59379.95 | |
| 792 | 24-138 | Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge. | Each | 1 | 641053.15 | 641053.15 | |
| 793 | ** DATA NETWORK & WIFI SYSTEM** | ||||||
| 794 | ** Data Cabling System** | ||||||
| 795 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge. | |||||
| 796 | a-ii) | UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher) | P.Rft | 2500 | 69.6 | 174000 | |
| 797 | 24-119 | Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge. | |||||
| 798 | i) | 1 meter Patch Cord | Each | 10 | 1074.4 | 10744 | |
| 799 | ii) | 3 meter Patch Cord | Each | 10 | 1309.6 | 13096 | |
| 800 | 24-124 | Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | Each | 1 | 4108.8 | 4108.8 | |
| 801 | 24-125 | Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge. | |||||
| 802 | ii) | CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit) | Each | 1 | 35405 | 35405 | |
| 803 | 24-141 | Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project. | |||||
| 804 | i) | Single I/O | Each | 10 | 1678.15 | 16781.5 | |
| 805 | 24-142 | Supply, Installation and commissioning of Core Switches with interface : 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 806 | i) | 24 Ports | Each | 1 | 125582.25 | 125582.25 | |
| 807 | 24-143 | Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 808 | 24 Ports | Each | 1 | 91902 | 91902 | ||
| 809 | 24-144 | Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge. | |||||
| 810 | a-(ii) | 06 Core | PER RFT | 500 | 596.4 | 298200 | |
| 811 | 24-145 | Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge | |||||
| 812 | a) | Multimode (MM) Ports | |||||
| 813 | (ii) | 12 Ports | Each | 1 | 64560.4 | 64560.4 | |
| 814 | 24-160 | Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge. | |||||
| 815 | b) Column Type Speaker | ||||||
| 816 | (iv) | 60 Watt | Each | 8 | 80081.25 | 640650 | |
| 817 | 24-162 | Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge. | |||||
| 818 | vi) | 480 Watt | Each | 1 | 468983.65 | 468983.65 | |
| 819 | 24-165 | Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge | |||||
| 820 | i) | Cordless Microphone with Transmitter | Each | 1 | 151462.9 | 151462.9 | |
| 821 | 24-166 | Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer Incharge | Each | 1 | 116294.25 | 116294.25 | |
| 822 | 24-15 | Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 823 | a)i | Flexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029") | Per Rft | 1000 | 128.45 | 128450 | |
| 824 | 24-93 | P/F PFI PLANT (Power Factor Improvement Plant) comprising ofcomponents of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors,Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 825 | i) | 62.5 KVAr | Each | 1 | 269555 | 269555 | |
| 826 | 24-85 | Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge | |||||
| 827 | a) | Single Pole | |||||
| 828 | (iii) | 6-63 Amp (10 KA) | Each | 60 | 1459.05 | 87543 | |
| 829 | b) | Double Pole | |||||
| 830 | iii) 6-63 Amp (10 KA) | Each | 2 | 5621.55 | 11243.1 | ||
| 831 | 24-86 | Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge | |||||
| 832 | a) | Triple Pole | |||||
| 833 | (iii) | 15-100 Amp(18 KA) | Each | 24 | 12172.95 | 292150.8 | |
| 834 | viii) | 125-150 Amp(36 KA) | Each | 5 | 26516.7 | 132583.5 | |
| 835 | 24-90 | (Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/Fwall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately). | |||||
| 836 | (a) | 6" deep | |||||
| 837 | (i) | 20~60A | P.CFT | 50 | 2463.7 | 123185 | |
| 838 | ii) | 75~100A | P.CFT | 20 | 2604.4 | 52088 | |
| 839 | (b) | 12" deep | |||||
| 840 | (i) | 125~150A | P.CFT | 20 | 7011.65 | 140233 | |
| 841 | ii) | 160~200A | P.CFT | 20 | 6188.55 | 123771 | |
| 842 | 24-91 | P/F floor mounted Electric Panel board of required depth and size,fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately). | |||||
| 843 | 1 | LT Switchboards | |||||
| 844 | a)(i) | 2.50 Ft deep 250~600A | P. cft | 30 | 4772.65 | 143179.5 | |
| 845 | 24-94 | Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge | |||||
| 846 | i) | Selector Switch | Each | 1 | 1228.8 | 1228.8 | |
| 847 | (ii) | Current Transformer Coil (Make: Metelx/Fico) | Each | 6 | 2134.3 | 12805.8 | |
| 848 | (iii) | Digital Voltmeter (0-600 Volt) | Each | 6 | 1012.8 | 6076.8 | |
| 849 | (iv) | Digital Ammeter (0-9999 Amp) | Each | 6 | 1228.8 | 7372.8 | |
| 850 | (v) | LED Phase Indicator | Each | 18 | 622.8 | 11210.4 | |
| 851 | (vi) | Push Button ON/OFF (Make: Schneider/Himal/Eqv.) | Each | 6 | 631.15 | 3786.9 | |
| 852 | vii) | Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB) | Each | 6 | 5373.8 | 32242.8 | |
| 853 | viii) | Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB) | Each | 18 | 1375.8 | 24764.4 | |
| 854 | ix) | Surge Suppressors | Each | 6 | 1060.8 | 6364.8 | |
| 855 | x) | Auto/Manual Switch 3-Steps (Make: GGT/Camsco) | Each | 1 | 2257.8 | 2257.8 | |
| 856 | xi) | Exhaust Fan with Louvers (Make: Imported/Plastim | Each | 3 | 3832.8 | 11498.4 | |
| 857 | xii) | Temperature Regulator 0~60C | Each | 3 | 2134.3 | 6402.9 | |
| 858 | xiii) | (Power Capacitors | Each | ||||
| 859 | a) | 12.5 KVAR | Each | 1 | 16852.8 | 16852.8 | |
| 860 | b) | 25 KVAR | Each | 1 | 25852.8 | 25852.8 | |
| 861 | Magnetic Contactor | ||||||
| 862 | (a) | 25 A (AC 3) for 12.5 KVAR | Each | 3 | 10048.8 | 30146.4 | |
| 863 | b) | 40 A (AC 3) for 25 KVAR | Each | 3 | 14332.8 | 42998.4 | |
| 864 | (xvii) | Power Factor Controller | |||||
| 865 | a) | 6 Steps | Each | 1 | 55252.8 | 55252.8 | |
| 866 | **Non - Schedule Items** | ||||||
| 867 | ** Light Fixtures** | ||||||
| 868 | Ref. Specs Sec. 8001, 8150 | ||||||
| 869 | Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details. | ||||||
| 870 | NS-01 | 40 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects. | No. | 5 | 9500 | 47500 | |
| 871 | NS-02 | (16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects. | No. | 10 | 2500 | 25000 | |
| 872 | NS-03 | 15-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 100 | 3500 | 350000 | |
| 873 | NS-04 | 7-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 5 | 1950 | 9750 | |
| 874 | NS-05 | Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better rated | No. | 20 | 6500 | 130000 | |
| 875 | NS-06 | LED EXIT LIGHT 8/10 W | No. | 10 | 9500 | 95000 | |
| 876 | Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation, condensate drain piping including Venture Cladding, fittings insulation, tape wraping etc, insulation, refrigerant charge thermostate, control between indoor and outdoor units power wiring, conduiting, dura duct / channel mounting brackets and accessories complete in all respect. | ||||||
| 877 | NS-07 | Split Air- Conditioner 1.5 ton | Job | 2 | 350000 | 700000 | |
| 878 | NS-08 | Cassette ceiling type Air- Conditioner 4 ton | Job | 4 | 1500000 | 6000000 | |
| 879 | NS-09 | Floor standing type Air- Conditioner 4 ton | Job | 10 | 1200000 | 12000000 | |
| 880 | **SWIMMING POOL & GYM** | ||||||
| 881 | **ELECTRICAL WORKS** | ||||||
| 882 | **Conduits & Pipes** | ||||||
| 883 | 24-3 | Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials. | |||||
| 884 | ii | 20 mm i/d | Rft. | 15000 | 119.35 | 1790250 | |
| 885 | iii | 25 mm i/d | Rft. | 16000 | 138.95 | 2223200 | |
| 886 | vi) | 50 mm i/d | Rft. | 2000 | 238.15 | 476300 | |
| 887 | vii) | 80 mm i/d | Rft. | 500 | 299.65 | 149825 | |
| 888 | viii) | 100 mm i/d | Rft. | 1000 | 377.65 | 377650 | |
| 889 | 24-105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenide or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge | |||||
| 890 | a) | One way Gange Switch (Small) | |||||
| 891 | (i) | 01 Gange | Each | 7 | 463.2 | 3242.4 | |
| 892 | (ii) | 02 Gange | Each | 12 | 704.4 | 8452.8 | |
| 893 | (iii) | Three pin Light Plug 10/13 Amp | Each | 50 | 754.45 | 37722.5 | |
| 894 | (iv) | Telephone / TV/Datacable socket | Each | 15 | 662.45 | 9936.75 | |
| 895 | (v) | Fan Dimmer | Each | 1 | 740.6 | 740.6 | |
| 896 | (vi) | Bell push | Each | 1 | 598.2 | 598.2 | |
| 897 | (vii) | Three Pin Power Plug 15-32 Amp | Each | 20 | 924.55 | 18491 | |
| 898 | b) | One way Gange Switch (Large) | |||||
| 899 | (i) | 04 Gange | Each | 8 | 981.25 | 7850 | |
| 900 | (ii) | 05 Gange | Each | 8 | 1151.35 | 9210.8 | |
| 901 | (iii) | 06 Gange | Each | 8 | 1405.85 | 11246.8 | |
| 902 | C) | Two way Gange Switch Small | |||||
| 903 | (i) | 01 Gange One Way/ Two Way | Each | 6 | 499.9 | 2999.4 | |
| 904 | Wiring | ||||||
| 905 | 24-8 | Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 906 | c) | 450/750 volts, PVC insulated: | |||||
| 907 | ii) | 1.5 mm sq (3/0.029") | Per Rft. | 18000 | 42.4 | 763200 | |
| 908 | iii) | 2.5 mm sq (7/0.029") | Per Rft. | 5800 | 62 | 359600 | |
| 909 | iv) | 4 mm sq (7/0.036") | Per Rft. | 5000 | 81.85 | 409250 | |
| 910 | LT Cables | ||||||
| 911 | 24-10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | |||||
| 912 | i) | 4 mm sq (7/0.036") | Per Rft. | 50 | 74.65 | 3732.5 | |
| 913 | ii) | 6 mm sq (7/0.044") | Per Rft. | 10 | 100.45 | 1004.5 | |
| 914 | iii) | 10 mm sq (7/0.052") | Per Rft. | 1000 | 155.7 | 155700 | |
| 915 | iv) | 16 mm sq (7/0.064") | Per Rft. | 100 | 234.3 | 23430 | |
| 916 | vii) | 70 mm sq (19/0.083") | Per Rft. | 500 | 917.85 | 458925 | |
| 917 | 24-11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- | |||||
| 918 | c) | PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:- | |||||
| 919 | iv) | 4 mm sq (7/0.036") | Per Rft. | 600 | 268.75 | 161250 | |
| 920 | v) | 6 mm sq (7/0.044") | Per Rft. | 250 | 381.4 | 95350 | |
| 921 | vi) | 10 mm sq (7/0.052") | Per Rft. | 500 | 605.85 | 302925 | |
| 922 | vii) | 16 mm sq (7/0.064") | Per Rft. | 300 | 926.05 | 277815 | |
| 923 | viii) | 25 mm sq (19/0.052") | Per Rft. | 500 | 1426.2 | 713100 | |
| 924 | ix) | 35 mm sq (19/0.064") | Per Rft. | 600 | 1919.9 | 1151940 | |
| 925 | Fans and Exhaust Fans | ||||||
| 926 | 24-102 | Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. | |||||
| 927 | a)-i | Plastic body - 10" dia | Each | 6 | 5235.5 | 31413 | |
| 928 | a)-ii | Plastic body - 12" dia | Each | 4 | 5685.5 | 22742 | |
| 929 | b) Steel body | ||||||
| 930 | i | 12" sweep | Each | 1 | 5516.75 | 5516.75 | |
| 931 | ii | 18" sweep | Each | 1 | 6641.75 | 6641.75 | |
| 932 | 24-103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 933 | ii) | 24" Sweep dia | Each | 15 | 10703 | 160545 | |
| 934 | 24-104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 935 | (iii) | 56" dia | Each | 1 | 10180.2 | 10180.2 | |
| 936 | Lightning Protection System | ||||||
| 937 | 24-111 | Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing) | P.Job | 5 | 21210.95 | 106054.75 | |
| 938 | 24-113 | Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System | |||||
| 939 | viii) | 70 mm² CU bare conductor | Per Rft | 300 | 850.45 | 255135 | |
| 940 | **CCTV** | ||||||
| 941 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 942 | a) | UTP (Unshielded Twisted pair) | |||||
| 943 | (i) | CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet system | Per Rft | 5000 | 49.2 | 246000 | |
| 944 | 24-126 | Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | |||||
| 945 | iii) | 32-Channel | Each | 1 | 131353.5 | 131353.5 | |
| 946 | 24-127 | Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge | |||||
| 947 | iii) | 10 TB | Each | 2 | 69360 | 138720 | |
| 948 | 24-128 | Supply, Installation and Connection of L2 Access Switches 24xEthernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge. | Each | 2 | 364102.5 | 728205 | |
| 949 | 24-131 | Supply, Installation and Connection of Fiber Optic SC-LC Patch CordsOS2 or OM3 of Specified Length from PoE Switch to ODF Point, UL Listed, Made of Schneider / Norden ,Pollo Australia or equivalent as approved and directed by Engineer Incharge | P.Rft | 250 | 1922 | 480500 | |
| 950 | 24-132 | Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 951 | b | 4 Mega PixeL | |||||
| 952 | (i) | Fixed Bullet Type | Each | 4 | 71535 | 286140 | |
| 953 | (ii) | Fixed Dome type | Each | 12 | 82785 | 993420 | |
| 954 | 24-139 | Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge | |||||
| 955 | ii | 15U size (600x550x770 mm | Each | 2 | 59379.95 | 118759.9 | |
| 956 | 24-138 | Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge. | Each | 1 | 641053.15 | 641053.15 | |
| 957 | **DATA NETWORK & WIFI SYSTEM** | ||||||
| 958 | **Data Cabling System** | ||||||
| 959 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge. | |||||
| 960 | a-ii) | UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher) | P.Rft | 5000 | 69.6 | 348000 | |
| 961 | 24-119 | Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge. | |||||
| 962 | i) | 1 meter Patch Cord | Each | 15 | 1074.4 | 16116 | |
| 963 | ii) | 3 meter Patch Cord | Each | 15 | 1309.6 | 19644 | |
| 964 | 24-124 | Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | Each | 2 | 4108.8 | 8217.6 | |
| 965 | 24-125 | Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge. | |||||
| 966 | ii) | CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit) | Each | 2 | 35405 | 70810 | |
| 967 | 24-141 | Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project. | |||||
| 968 | i) | Single I/O | Each | 15 | 1678.15 | 25172.25 | |
| 969 | 24-142 | Supply, Installation and commissioning of Core Switches with interface: 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP), Bandwidth: Tbps or higher with Quad-core processor or higher, MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 970 | i) | 24 Ports | Each | 2 | 125582.25 | 251164.5 | |
| 971 | 24-143 | Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity: 90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei/ H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 972 | 24 Ports | Each | 1 | 91902 | 91902 | ||
| 973 | 24-144 | Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed, in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider /Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge. | |||||
| 974 | a(ii) | 06 Core | PER RFT | 1000 | 596.4 | 596400 | |
| 975 | 24-145 | Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge | |||||
| 976 | a) | Multimode (MM) Ports | |||||
| 977 | (ii) | 12 Ports | Each | 1 | 64560.4 | 64560.4 | |
| 978 | 24-160 | Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge. | |||||
| 979 | b) Column Type Speaker | ||||||
| 980 | (iv) | 60 Watt | Each | 8 | 80081.25 | 640650 | |
| 981 | 24-162 | Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge. | |||||
| 982 | vi) | 480 Watt | Each | 1 | 468983.65 | 468983.65 | |
| 983 | 24-165 | Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge | |||||
| 984 | i) | Cordless Microphone with Transmitter | Each | 1 | 151462.9 | 151462.9 | |
| 985 | 24-166 | Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer Incharge | Each | 1 | 116294.25 | 116294.25 | |
| 986 | 24-15 | Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 987 | a)-i | Flexible 3 core, 600/1000 volt non armoured cable:- 1.5sqm (3/.029") | Per Rft | 1000 | 128.45 | 128450 | |
| 988 | 24-93 | P/F PFI PLANT (Power Factor Improvement Plant) comprising of components of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors, Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 989 | i) | 62.5KVAr | Each | 1 | 269555 | 269555 | |
| 990 | 24-85 | Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge | |||||
| 991 | a) | Single Pole | |||||
| 992 | (iii) | 6-63 Amp (10 KA) | Each | 100 | 1459.05 | 145905 | |
| 993 | b) | Double Pole | |||||
| 994 | iii) 6-63 Amp (10 KA) | Each | 2 | 5621.55 | 11243.1 | ||
| 995 | 24-86 | Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge | |||||
| 996 | a) | Triple Pole | |||||
| 997 | (iii) | 15-100 Amp(18 KA) | Each | 48 | 12172.95 | 584301.6 | |
| 998 | viii) | 125-150 Amp(36 KA) | Each | 10 | 26516.7 | 265167 | |
| 999 | (ix) | 200-250 Amp(36 KA) | Each | 6 | 47329.2 | 283975.2 | |
| 1000 | x) | 300-630 Amp(36 KA) | Each | 2 | 93383.35 | 186766.7 | |
| 1001 | 24-90 | (Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector switch, Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately). | |||||
| 1002 | (a) | 6" deep | |||||
| 1003 | (i) | 20~60A | P.CFT | 100 | 2463.7 | 246370 | |
| 1004 | ii) | 75~100A | P.CFT | 50 | 2604.4 | 130220 | |
| 1005 | (b) | 12" deep | |||||
| 1006 | (i) | 125~150A | P.CFT | 40 | 7011.65 | 280466 | |
| 1007 | ii) | 160~200A | P.CFT | 40 | 6188.55 | 247542 | |
| 1008 | 24-91 | P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately). | |||||
| 1009 | 1 | LT Switchboards | |||||
| 1010 | a)(i) | 2.50 Ft deep 250~600A | P. cft | 50 | 4772.65 | 238632.5 | |
| 1011 | 24-94 | Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge | |||||
| 1012 | i) | Selector Switch | Each | 2 | 1228.8 | 2457.6 | |
| 1013 | (ii) | Current Transformer Coil (Make: Metelx/Fico) | Each | 12 | 2134.3 | 25611.6 | |
| 1014 | (iii) | Digital Voltmeter (0-600 Volt) | Each | 12 | 1012.8 | 12153.6 | |
| 1015 | (iv) | Digital Ammeter (0-9999 Amp) | Each | 12 | 1228.8 | 14745.6 | |
| 1016 | (v) | LED Phase Indicator | Each | 36 | 622.8 | 22420.8 | |
| 1017 | (vi) | Push Button ON/OFF (Make: Schneider/Himal/Eqv.) | Each | 12 | 631.15 | 7573.8 | |
| 1018 | vii) | Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB) | Each | 12 | 5373.8 | 64485.6 | |
| 1019 | viii) | Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB) | Each | 36 | 1375.8 | 49528.8 | |
| 1020 | ix) | Surge Suppressors | Each | 12 | 1060.8 | 12729.6 | |
| 1021 | x) | Auto/Manual Switch 3-Steps (Make: GGT/Camsco) | Each | 2 | 2257.8 | 4515.6 | |
| 1022 | xi) | Exhaust Fan with Louvers (Make: Imported/Plastim | Each | 6 | 3832.8 | 22996.8 | |
| 1023 | xii) | Temperature Regulator 0~60C | Each | 6 | 2134.3 | 12805.8 | |
| 1024 | xiii) | (Power Capacitors | Each | ||||
| 1025 | a) | 12.5 KVAR | Each | 2 | 16852.8 | 33705.6 | |
| 1026 | b) | 25 KVAR | Each | 2 | 25852.8 | 51705.6 | |
| 1027 | c) | 50 KVAR | Each | 1 | 66052.8 | 66052.8 | |
| 1028 | Magnetic Contactor | ||||||
| 1029 | (a) | 25 A (AC 3) for 12.5 KVAR | Each | 6 | 10048.8 | 60292.8 | |
| 1030 | b) | 40 A (AC 3) for 25 KVAR | Each | 6 | 14332.8 | 85996.8 | |
| 1031 | (xvii) | Power Factor Controller | |||||
| 1032 | a) | 6 Steps | Each | 2 | 55252.8 | 110505.6 | |
| 1033 | **Non -Schedule Items** | ||||||
| 1034 | **Light Fixtures** | ||||||
| 1035 | Ref. Specs Sec. 8001, 8150 | ||||||
| 1036 | Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders, SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details. | ||||||
| 1037 | NS-01 | 40 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects. | No. | 10 | 9500 | 95000 | |
| 1038 | NS-02 | (16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects. | No. | 20 | 2500 | 50000 | |
| 1039 | NS-03 | 15-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 300 | 3500 | 1050000 | |
| 1040 | NS-04 | 7-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 5 | 1950 | 9750 | |
| 1041 | NS-05 | Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better rated | No. | 20 | 6500 | 130000 | |
| 1042 | NS-06 | LED EXIT LIGHT 8/10 W | No. | 20 | 9500 | 190000 | |
| 1043 | NS-07 | 20 watt under water light ip 67 | No. | 20 | 45000 | 900000 | |
| 1044 | Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding , fittings insulation,tape wraping etc , insulation,refrigerant charge thermostate ,control between indoor and outdoor units power wiring , conduiting , dura duct / channel mounting brackets and accessories complete in all respect. | ||||||
| 1045 | NS-08 | Split Air- Conditioner 1.5 ton | Job | 4 | 350000 | 1400000 | |
| 1046 | NS-09 | Cassette ceiling type Air- Conditioner 4 ton | Job | 4 | 1500000 | 6000000 | |
| 1047 | NS-10 | Floor standing type Air- Conditioner 4 ton | Job | 15 | 1200000 | 18000000 | |
| 1048 | **BADMINTON HAL** | ||||||
| 1049 | **ELECTRICAL WORKS** | ||||||
| 1050 | **Conduits & Pipes** | ||||||
| 1051 | 24-3 | Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials. | |||||
| 1052 | ii | 20 mm i/d | Rft. | 3800 | 119.35 | 453530 | |
| 1053 | iii | 25 mm i/d | Rft. | 3700 | 138.95 | 514115 | |
| 1054 | vi) | 50 mm i/d | Rft. | 500 | 238.15 | 119075 | |
| 1055 | vii) | 80 mm i/d | Rft. | 250 | 299.65 | 74912.5 | |
| 1056 | viii) | 100 mm i/d | Rft. | 800 | 377.65 | 302120 | |
| 1057 | 24-105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge | |||||
| 1058 | a) | One way Gange Switch (Small) | |||||
| 1059 | (i) | 01 Gange | Each | 3 | 463.2 | 1389.6 | |
| 1060 | (ii) | 02 Gange | Each | 5 | 704.4 | 3522 | |
| 1061 | (iii) | Three pin Light Plug 10/13 Amp | Each | 22 | 754.45 | 16597.9 | |
| 1062 | (iv) | Telephone / TV/Datacable socket | Each | 10 | 662.45 | 6624.5 | |
| 1063 | (v) | Fan Dimmer | Each | 1 | 740.6 | 740.6 | |
| 1064 | (vi) | Bell push | Each | 1 | 598.2 | 598.2 | |
| 1065 | (vii) | Three Pin Power Plug 15-32 Amp | Each | 8 | 924.55 | 7396.4 | |
| 1066 | b) | One way Gange Switch (Large) | |||||
| 1067 | (i) | 04 Gange | Each | 4 | 981.25 | 3925 | |
| 1068 | (ii) | 05 Gange | Each | 4 | 1151.35 | 4605.4 | |
| 1069 | (iii) | 06 Gange | Each | 4 | 1405.85 | 5623.4 | |
| 1070 | C) | Two way Gange Switch Small | |||||
| 1071 | (i) | 01 Gange One Way/ Two Way | Each | 3 | 499.9 | 1499.7 | |
| 1072 | **Wiring** | ||||||
| 1073 | 24-8 | Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 1074 | c) | 450/750 volts, PVC insulated: | |||||
| 1075 | ii) | 1.5 mm sq (3/0.029") | Per Rft. | 6500 | 42.4 | 275600 | |
| 1076 | iii) | 2.5 mm sq (7/0.029") | Per Rft. | 3300 | 62 | 204600 | |
| 1077 | iv) | 4 mm sq (7/0.036") | Per Rft. | 2800 | 81.85 | 229180 | |
| 1078 | **LT Cables** | ||||||
| 1079 | 24-10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | |||||
| 1080 | i) | 4 mm sq (7/0.036") | Per Rft. | 50 | 74.65 | 3732.5 | |
| 1081 | ii) | 6 mm sq (7/0.044") | Per Rft. | 10 | 100.45 | 1004.5 | |
| 1082 | iii) | 10 mm sq (7/0.052") | Per Rft. | 250 | 155.7 | 38925 | |
| 1083 | iv) | 16 mm sq (7/0.064") | Per Rft. | 50 | 234.3 | 11715 | |
| 1084 | 24-11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- | |||||
| 1085 | c) | PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:- | |||||
| 1086 | iv) | 4 mm sq (7/0.036") | Per Rft. | 250 | 268.75 | 67187.5 | |
| 1087 | v) | 6 mm sq (7/0.044") | Per Rft. | 20 | 381.4 | 7628 | |
| 1088 | vi) | 10 mm sq (7/0.052") | Per Rft. | 150 | 605.85 | 90877.5 | |
| 1089 | vii) | 16 mm sq (7/0.064") | Per Rft. | 150 | 926.05 | 138907.5 | |
| 1090 | viii) | 25 mm sq (19/0.052") | Per Rft. | 20 | 1426.2 | 28524 | |
| 1091 | ix) | 35 mm sq (19/0.064") | Per Rft. | 150 | 1919.9 | 287985 | |
| 1092 | Fans and Exhaust Fans | ||||||
| 1093 | 24-102 | Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. | |||||
| 1094 | a)-i | Plastic body - 10" dia | Each | 2 | 5235.5 | 10471 | |
| 1095 | a)-ii | Plastic body - 12" dia | Each | 1 | 5685.5 | 5685.5 | |
| 1096 | b) Steel body | ||||||
| 1097 | i | 12" sweep | Each | 1 | 5516.75 | 5516.75 | |
| 1098 | ii | 18" sweep | Each | 6641.75 | |||
| 1099 | 24-103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 1100 | ii) | 24" Sweep dia | Each | 4 | 10703 | 42812 | |
| 1101 | 24-104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 1102 | (iii) | 56" dia | Each | 1 | 10180.2 | 10180.2 | |
| 1103 | **Lightning Protection System** | ||||||
| 1104 | 24-111 | Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link coppe plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing) | P.Job | 2 | 21210.95 | 42421.9 | |
| 1105 | 24-113 | Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System | |||||
| 1106 | viii) | 70 mm² CU bare conductor | Per Rft | 200 | 850.45 | 170090 | |
| 1107 | **CCTV** | ||||||
| 1108 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 1109 | a) | UTP (Unshielded Twisted pair) | |||||
| 1110 | (i) | CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet system | Per Rft | 1200 | 49.2 | 59040 | |
| 1111 | 24-126 | Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | |||||
| 1112 | ii) | 16-Channel | Each | 1 | 116388.7 | 116388.7 | |
| 1113 | 24-127 | Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge | |||||
| 1114 | iii) | 10 TB | Each | 1 | 69360 | 69360 | |
| 1115 | 24-128 | Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2 x 1 Gigabit SFP ports with 2 x 1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge. | Each | 1 | 364102.5 | 364102.5 | |
| 1116 | 24-132 | Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 1117 | b | 4 Mega PixeL | |||||
| 1118 | (i) | Fixed Bullet Type | Each | 1 | 71535 | 71535 | |
| 1119 | (ii) | Fixed Dome type | Each | 5 | 82785 | 413925 | |
| 1120 | 24-139 | Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge | |||||
| 1121 | ii | 15U size (600 x 550 x 770 mm) | Each | 1 | 59379.95 | 59379.95 | |
| 1122 | 24-138 | Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge. | Each | 1 | 641053.15 | 641053.15 | |
| 1123 | **DATA NETWORK & WIFI SYSTEM** | ||||||
| 1124 | **Data Cabling System** | ||||||
| 1125 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge. | |||||
| 1126 | a-ii) | UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher) | P.Rft | 1500 | 69.6 | 104400 | |
| 1127 | 24-119 | Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge. | |||||
| 1128 | i) | 1 meter Patch Cord | Each | 8 | 1074.4 | 8595.2 | |
| 1129 | ii) | 3 meter Patch Cord | Each | 8 | 1309.6 | 10476.8 | |
| 1130 | 24-124 | Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | Each | 1 | 4108.8 | 4108.8 | |
| 1131 | 24-125 | Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge. | |||||
| 1132 | ii) | CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit) | Each | 1 | 35405 | 35405 | |
| 1133 | 24-141 | Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project. | |||||
| 1134 | i) | Single I/O | Each | 8 | 1678.15 | 13425.2 | |
| 1135 | 24-142 | Supply, Installation and commissioning of Core Switches with interface : 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 1136 | i) | 24 Ports | Each | 1 | 125582.25 | 125582.25 | |
| 1137 | 24-143 | Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge. | |||||
| 1138 | 24 Ports | Each | 1 | 91902 | 91902 | ||
| 1139 | 24-144 | Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge. | |||||
| 1140 | a(ii) | 06 Core | PER RFT | 250 | 596.4 | 149100 | |
| 1141 | 24-145 | Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge | |||||
| 1142 | a) | Multimode (MM) Ports | |||||
| 1143 | (ii) | 12 Ports | Each | 1 | 64560.4 | 64560.4 | |
| 1144 | 24--160 | Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge. | |||||
| 1145 | b) Column Type Speaker | ||||||
| 1146 | (iv) | 60 Watt | Each | 4 | 80081.25 | 320325 | |
| 1147 | 24-162 | Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge. | |||||
| 1148 | vi) | 480 Watt | Each | 1 | 468983.65 | 468983.65 | |
| 1149 | 24-165 | Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge | |||||
| 1150 | i) | Cordless Microphone with Transmitter | Each | 1 | 151462.9 | 151462.9 | |
| 1151 | 24-166 | Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer Incharge | Each | 1 | 116294.25 | 116294.25 | |
| 1152 | 24-15 | Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 1153 | a)-i | Flexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029") | Per Rft | 500 | 128.45 | 64225 | |
| 1154 | 24-85 | Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge | |||||
| 1155 | a) | Single Pole | |||||
| 1156 | (iii) | 6-63 Amp (10 KA) | Each | 40 | 1459.05 | 58362 | |
| 1157 | b) | Double Pole | |||||
| 1158 | iii) | 6-63 Amp (10 KA) | Each | 1 | 5621.55 | 5621.55 | |
| 1159 | 24-86 | Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge | |||||
| 1160 | a) | Triple Pole | |||||
| 1161 | (iii) | 15-100 Amp(18 KA) | Each | 12 | 12172.95 | 146075.4 | |
| 1162 | viii) | 125-150 Amp(36 KA) | Each | 3 | 26516.7 | 79550.1 | |
| 1163 | 24-90 | (Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately). | |||||
| 1164 | (a) | 6" deep | |||||
| 1165 | (i) | 20~60A | P.CFT | 30 | 2463.7 | 73911 | |
| 1166 | ii) | 75~100A | P.CFT | 20 | 2604.4 | 52088 | |
| 1167 | (b) | 12" deep | |||||
| 1168 | (i) | 125~150A | P.CFT | 20 | 7011.65 | 140233 | |
| 1169 | 24-91 | P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately). | |||||
| 1170 | 1 | LT Switchboards | |||||
| 1171 | a)(i) | 2.50 Ft deep 250~600A | P. cft | 20 | 4772.65 | 95453 | |
| 1172 | 24-94 | Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge | |||||
| 1173 | i) | Selector Switch | Each | 1 | 1228.8 | 1228.8 | |
| 1174 | (ii) | Current Transformer Coil (Make: Metelx/Fico) | Each | 6 | 2134.3 | 12805.8 | |
| 1175 | (iii) | Digital Voltmeter (0-600 Volt) | Each | 6 | 1012.8 | 6076.8 | |
| 1176 | (iv) | Digital Ammeter (0-9999 Amp) | Each | 6 | 1228.8 | 7372.8 | |
| 1177 | (v) | LED Phase Indicator | Each | 9 | 622.8 | 5605.2 | |
| 1178 | (vi) | Push Button ON/OFF (Make: Schneider/Himal/Eqv.) | Each | 6 | 631.15 | 3786.9 | |
| 1179 | vii) | Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB) | Each | 6 | 5373.8 | 32242.8 | |
| 1180 | viii) | Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB) | Each | 9 | 1375.8 | 12382.2 | |
| 1181 | ix) | Surge Suppressors | Each | 6 | 1060.8 | 6364.8 | |
| 1182 | x) | Auto/Manual Switch 3-Steps (Make: GGT/Camsco) | Each | 1 | 2257.8 | 2257.8 | |
| 1183 | xi) | Exhaust Fan with Louvers (Make: Imported/Plastim | Each | 3 | 3832.8 | 11498.4 | |
| 1184 | xii) | Temperature Regulator 0~60C | Each | 3 | 2134.3 | 6402.9 | |
| 1185 | xiii) | (Power Capacitors | Each | ||||
| 1186 | a) | 12.5 KVAR | Each | 1 | 16852.8 | 16852.8 | |
| 1187 | b) | 25 KVAR | Each | 1 | 25852.8 | 25852.8 | |
| 1188 | Magnetic Contactor | ||||||
| 1189 | (a) | 25 A (AC 3) for 12.5 KVAR | Each | 3 | 10048.8 | 30146.4 | |
| 1190 | b) | 40 A (AC 3) for 25 KVAR | Each | 3 | 14332.8 | 42998.4 | |
| 1191 | (xvii) | Power Factor Controller | |||||
| 1192 | a) | 6 Steps | Each | 1 | 55252.8 | 55252.8 | |
| 1193 | **Non - Schedule Items** | ||||||
| 1194 | **Light Fixtures** | ||||||
| 1195 | Ref. Specs Sec. 8001, 8150 | ||||||
| 1196 | Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders, SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details. | ||||||
| 1197 | NS-01 | 40 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects. | No. | 2 | 9500 | 19000 | |
| 1198 | NS-02 | (16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects. | No. | 6 | 2500 | 15000 | |
| 1199 | NS-03 | 15-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 60 | 3500 | 210000 | |
| 1200 | NS-04 | 7-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser | No. | 5 | 1950 | 9750 | |
| 1201 | NS-05 | Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better rated | No. | 8 | 6500 | 52000 | |
| 1202 | NS-06 | LED EXIT LIGHT 8/10 W | No. | 5 | 9500 | 47500 | |
| 1203 | Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding , fittings insulation,tape wraping etc , insulation,refrigerant charge thermostate ,control between indoor and outdoor units power wiring , conduiting , dura duct / channel mounting brackets and accessories complete in all respect. | ||||||
| 1204 | NS-07 | Split Air- Conditioner 1.5 ton | Job | 4 | 350000 | 1400000 | |
| 1205 | NS-08 | Floor standing type Air- Conditioner 4 ton | Job | 4 | 1200000 | 4800000 | |
| 1206 | **EXTERNAL Electrical Works** | ||||||
| 1207 | **ELECTRICAL WORKS** | ||||||
| 1208 | **Conduits & Pipes** | ||||||
| 1209 | 24-3 | Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials. | |||||
| 1210 | ii | 20 mm i/d | Rft. | 1000 | 119.35 | 119350 | |
| 1211 | iii | 25 mm i/d | Rft. | 1000 | 138.95 | 138950 | |
| 1212 | vi) | 50 mm i/d | Rft. | 3000 | 238.15 | 714450 | |
| 1213 | vii) | 80 mm i/d | Rft. | 1000 | 299.65 | 299650 | |
| 1214 | viii) | 100 mm i/d | Rft. | 2000 | 377.65 | 755300 | |
| 1215 | 24-105 | P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenide or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge | |||||
| 1216 | a) | One way Gange Switch (Small) | |||||
| 1217 | (i) | 01 Gange | Each | 4 | 463.2 | 1852.8 | |
| 1218 | (ii) | 02 Gange | Each | 2 | 704.4 | 1408.8 | |
| 1219 | (iii) | Three pin Light Plug 10/13 Amp | Each | 5 | 754.45 | 3772.25 | |
| 1220 | (vii) | Three Pin Power Plug 15-32 Amp | Each | 10 | 924.55 | 9245.5 | |
| 1221 | **Wiring** | ||||||
| 1222 | 24-8 | Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):- | |||||
| 1223 | c) | 450/750 volts, PVC insulated: | |||||
| 1224 | ii) | 1.5 mm sq (3/0.029") | Per Rft. | 2000 | 42.4 | 84800 | |
| 1225 | iii) | 2.5 mm sq (7/0.029") | Per Rft. | 2000 | 62 | 124000 | |
| 1226 | iv) | 4 mm sq (7/0.036") | Per Rft. | 4000 | 81.85 | 327400 | |
| 1227 | **LT Cables** | ||||||
| 1228 | 24-10 | Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):- | |||||
| 1229 | i) | 4 mm sq (7/0.036") | Per Rft. | 100 | 74.65 | 7465 | |
| 1230 | ii) | 6 mm sq (7/0.044") | Per Rft. | 100 | 100.45 | 10045 | |
| 1231 | iii) | 10 mm sq (7/0.052") | Per Rft. | 200 | 155.7 | 31140 | |
| 1232 | iv) | 16 mm sq (7/0.064") | Per Rft. | 200 | 234.3 | 46860 | |
| 1233 | v) | 25 mm sq (19/0.052") | Per Rft. | 500 | 358.5 | 179250 | |
| 1234 | 24-11 | Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):- | |||||
| 1235 | b) | Three core, 600/1000 volt cable:- | |||||
| 1236 | iii) | 7/0.74 mm (7/0.029") | Per Rft. | 3000 | 141.1 | 423300 | |
| 1237 | c) | PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:- | |||||
| 1238 | iv) | 4 mm sq (7/0.036") | Per Rft. | 200 | 268.75 | 53750 | |
| 1239 | v) | 6 mm sq (7/0.044") | Per Rft. | 100 | 381.4 | 38140 | |
| 1240 | vi) | 10 mm sq (7/0.052") | Per Rft. | 250 | 605.85 | 151462.5 | |
| 1241 | vii) | 16 mm sq (7/0.064") | Per Rft. | 2000 | 926.05 | 1852100 | |
| 1242 | viii) | 25 mm sq (19/0.052") | Per Rft. | 600 | 1426.2 | 855720 | |
| 1243 | **Fans and Exhaust Fans** | ||||||
| 1244 | 24-102 | Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge. | |||||
| 1245 | a)-i | Plastic body - 10" dia | Each | 2 | 5235.5 | 10471 | |
| 1246 | 24-103 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 1247 | ii) | 24" Sweep dia | Each | 1 | 10703 | 10703 | |
| 1248 | 24-104 | Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge. | |||||
| 1249 | (iii) | 56" dia | Each | 1 | 10180.2 | 10180.2 | |
| 1250 | **Lightning Protection System** | ||||||
| 1251 | 24-111 | Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers plugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing) | P.Job | 80 | 21210.95 | 1696876 | |
| 1252 | 24-113 | Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System | |||||
| 1253 | viii) | 70 mm² CU bare conductor | Per Rft | 1000 | 850.45 | 850450 | |
| 1254 | **CCTV** | ||||||
| 1255 | 24-116 | Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge. | |||||
| 1256 | a) | UTP (Unshielded Twisted pair) | |||||
| 1257 | (i) | CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet system | Per Rft | 6500 | 49.2 | 319800 | |
| 1258 | 24-126 | Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge. | |||||
| 1259 | iii) | 32-Channel | Each | 1 | 131353.5 | 131353.5 | |
| 1260 | 24-127 | Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge | |||||
| 1261 | iii) | 10 TB | Each | 2 | 69360 | 138720 | |
| 1262 | 24-128 | Supply, Installation and Connection of L2 Access Switches 24xEthernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge. | Each | 1 | 364102.5 | 364102.5 | |
| 1263 | 24-129 | Supply, Installation and Connection of Layer-3, CoreSwitches, of specified speeds, supporting 10 Giga SFP+ (Small Form Pluggable +) Tranceiver, Switching Capacity at least 500 Gbps or higher ,supporting bidirectional ACL,port-based ACL., Stackable or Cluster setup complete with stacking cable, Stack modules, necessary licenses made of Cisco/ HP / Planet/Huawei/H3C Pollo Australia or equivalent approved manufacturer i/c the cost of tags as approved and directed by Engineer Incharge | |||||
| 1264 | a) | 10/100/1000 | |||||
| 1265 | (i) | 12 port(SFP) | Each | 2 | 645777.75 | 1291555.5 | |
| 1266 | 24-130 | Supply and installation of ODF (Optical Distribution frame) having specified ports,mounting tray loaded, including Splicing, labeling, tagging, support for OM3 multi mode fibre, duplex adopters, and simplex pig-tails. Make Schneider, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge | |||||
| 1267 | (ii) | 12 Port | Each | 1 | 69148.5 | 69148.5 | |
| 1268 | 24-131 | Supply, Installation and Connection of Fiber Optic SC-LC Patch Cords OS2 or OM3 of Specified Length from PoE Switch to ODF Point, UL Listed, Made of Schneider / Norden ,Pollo Australia or equivalent as approved and directed by Engineer Incharge | P.Rft | 500 | 1922 | 961000 | |
| 1269 | 24-132 | Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 1270 | b | 4 Mega PixeL | |||||
| 1271 | (i) | Fixed Bullet Type | Each | 25 | 71535 | 1788375 | |
| 1272 | 24-139 | Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge | |||||
| 1273 | ii | 15U size (600 x 550 x 770 mm | Each | 2 | 59379.95 | 118759.9 | |
| 1274 | 24-138 | Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge. | Each | 5 | 641053.15 | 3205265.75 | |
| 1275 | 24-136 | Supply, installation & connecting outdoor PTZ (Pan-Tilt-Zoom),IP based Camera of specified resolution, lens,motorized varfocal,AL & AF function,specified optical zoom,D/N function-IR cut filter,Video content analysis,micro SD card support, Min, illumination:face recognition, specified IR LED range RANGE i/c the cost of mounting bracket, accessories, made of AXIS Europe/NOVAS Europe/Avigilon by Motorla USA/Bosch Germany, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge | |||||
| 1276 | iii) | 4.0 MPxl, Optical zoom 30x,Digital zoom 16x,,laser distance 200 meter, Main stream H-264+/265+, sub stream H.264/265, Third Stream H.264/265, Max resolution 2560 x 1440 with 30 fps, IP-67 | Each | 1 | 520635 | 520635 | |
| 1277 | 24-69 | Supplying, installation testing and commissioning of Octagonal shape electric street light pole, made of hot dipped 4.5 mm thick (7 SWG) galvanized steel, tappered from 225 mm at bottom to 100 mm at top, with 1500 mm x 60 mm x 4mm thick dia. arm for luminaire installation, duly G.I.welded with 70x470x20 mm base plate with the help of 4 no triangular stiffeners 100x350x20 mm of GI sheet, with built in junction box with shutter, i/c the cost of nuts & J-rag bolts, duly fixed in prelaid concrete foundation, foundation will be paid additionally as approved and directed by the Engineer In charge | |||||
| 1278 | a) Single Arm | ||||||
| 1279 | (i) | 8 mtr height | Each | 40 | 107310.3 | 4292412 | |
| 1280 | 24-70 | Supplying, installation and commissioning of LED Cobra-head Luminaries of specified wattage and lumens conforming to IP 66 & IK 08 or above Philips/Osram/Thorn or NEECA approved equivalent manufacturer with corrosion resistant die casted Aluminum housing, silicon gasket in special groove, UV stable & scratch resistant synthetic materials, thermally hardened glass complete with LED Chip (Philips Lumiled/Cree/Nichia/Osram make or equivalent approved manufacturer), programmable LED driver (Harvard/TCI/Lumotech/Philips/VOSSLOH Schwabe/Lightech make or approved equivalent manufacturer), minimum 10kV surge protection rating device i/c the cost of all accessories/components required for proper operation, fully flexible for future upgradation and easy replacements for maintenance purposes, bucket elevator charges as approved and directed by the Engineer Incharge. | |||||
| 1281 | a) | 140 Lm/Watt | |||||
| 1282 | iv) | 90 Watt with 12600 Lumens | Each | 40 | 41540.4 | 1661616 | |
| 1283 | 24-93 | P/F PFI PLANT (Power Factor Improvement Plant) comprising ofcomponents of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors, Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge. | |||||
| 1284 | i) | 62.5KVAr | Each | 1 | 269555 | 269555 | |
| 1285 | 24-85 | Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge | |||||
| 1286 | a) | Single Pole | |||||
| 1287 | (iii) | 6-63 Amp (10 KA) | Each | 48 | 1459.05 | 70034.4 | |
| 1288 | b) | Double Pole | |||||
| 1289 | iii) | 6-63 Amp (10 KA) | Each | 2 | 5621.55 | 11243.1 | |
| 1290 | 24-86 | Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge | |||||
| 1291 | a) | Triple Pole | |||||
| 1292 | (iii) | 15-100 Amp(18 KA) | Each | 2 | 12172.95 | 24345.9 | |
| 1293 | viii) | 125-150 Amp(36 KA) | Each | 1 | 26516.7 | 26516.7 | |
| 1294 | 24-90 | (Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights, Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter ,Digital Ammeter, Volt Selector Switch,Ammeter selector switch, Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately). | |||||
| 1295 | (a) | 6" deep | |||||
| 1296 | (i) | 20~60A | P.CFT | 20 | 2463.7 | 49274 | |
| 1297 | ii) | 75~100A | P.CFT | 10 | 2604.4 | 26044 | |
| 1298 | 24-92 | P/F floor mounted ATS (Auto Transfer Switch) panel board , fabricarted with 14S WG M.S sheet (Indoor Type) duly painted with 100 microns powder coated paint in approved colour, front access, extendable, insulation class of 600 volts IP-44, incomimg & outgoing connections from bottom with flexible copper cable suitable for 415 VAC, 3-phase 4 wire, 50 HZ TPN&E system having rated service, short circuit breaking capacity at 400VAC conformimg to IEC-947-2 to accomodate given no of circuit components, instruments & accessories,assembled & wired with Electrolitic Copper bus bars at 50 deg and cables duly cleaned down to bare shining metal phosphate, manual change Over i/c the cost of Lock, Indication lights, Brass glands, Netural & Earth bar, thimbles, Digital volt meter/ Amp meter, Selector switch, Current transformers, Controles, Channels, Copper bus bars of specified capacity, Relays, Door Earthing, complete in all respects as approved and directed by the Engineer Incharge. (Breakers wil be paid additionally) | |||||
| 1299 | b) 2.00 Ft deep (i)125-250 KVA | Each | 1 | 2349389.05 | 2349389.05 | ||
| 1300 | 24-94 | Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge | |||||
| 1301 | i) | Selector Switch | Each | 5 | 1228.8 | 6144 | |
| 1302 | (ii) | Current Transformer Coil (Make: Metelx/Fico) | Each | 10 | 2134.3 | 21343 | |
| 1303 | (iii) | Digital Voltmeter (0-600 Volt) | Each | 4 | 1012.8 | 4051.2 | |
| 1304 | (iv) | Digital Ammeter (0-9999 Amp) | Each | 10 | 1228.8 | 12288 | |
| 1305 | (v) | LED Phase Indicator | Each | 12 | 622.8 | 7473.6 | |
| 1306 | (vi) | Push Button ON/OFF (Make: Schneider/Himal/Eqv.) | Each | 15 | 631.15 | 9467.25 | |
| 1307 | vii) | Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB) | Each | 18 | 5373.8 | 96728.4 | |
| 1308 | viii) | Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB) | Each | 18 | 1375.8 | 24764.4 | |
| 1309 | ix) | Surge Suppressors | Each | 6 | 1060.8 | 6364.8 | |
| 1310 | x) | Auto/Manual Switch 3-Steps (Make: GGT/Camsco) | Each | 5 | 2257.8 | 11289 | |
| 1311 | xi) | Exhaust Fan with Louvers (Make: Imported/Plastim | Each | 5 | 3832.8 | 19164 | |
| 1312 | xii) | Temperature Regulator 0~60C | Each | 6 | 2134.3 | 12805.8 | |
| 1313 | xiii) | (Power Capacitors | Each | ||||
| 1314 | a) | 12.5 KVAR | Each | 1 | 16852.8 | 16852.8 | |
| 1315 | b) | 25 KVAR | Each | 1 | 25852.8 | 25852.8 | |
| 1316 | c) | 50 KVAR | Each | 1 | 66052.8 | 66052.8 | |
| 1317 | (d) | 100 KVAR | Each | 1 | 188030.4 | 188030.4 | |
| 1318 | Magnetic Contactor | ||||||
| 1319 | (a) | 25 A (AC 3) for 12.5 KVAR | Each | 2 | 10048.8 | 20097.6 | |
| 1320 | b) | 40 A (AC 3) for 25 KVAR | Each | 3 | 14332.8 | 42998.4 | |
| 1321 | © | 80 A (AC 3) for 50 KVAR | Each | 2 | 26932.8 | 53865.6 | |
| 1322 | (xvii) | Power Factor Controller | |||||
| 1323 | a) | 6 Steps | Each | 1 | 55252.8 | 55252.8 | |
| 1324 | b) | 12 Steps | Each | 1 | 64252.8 | 64252.8 | |
| 1325 | **Non - Schedule Items** | ||||||
| 1326 | **HT CABLES & SYSTEM (8.7/15 kV)** | ||||||
| 1327 | (Ref. Specification Section-8001 8211 ) | ||||||
| 1328 | NS-01 | Supply & Installation of 1 core, 240 mm2 8.7/15 kV Aluminum conductors, XLPE cable as per requirements of the MV distribution system as per WAPDA/IESCO standards. | Meter | 40 | 5100 | 204000 | |
| 1329 | TRANSFORMERS | ||||||
| 1330 | NS-02 | Supply, Installation, testing , Commissioning, of Outdoor type 400KVA, three phase, 11/0.415 kV PAD mounted transformer.The complete unit shall be designed, fabricated and commissioned as per latest WAPDA's technical specifications. It shall also include the cost of mounting and installation material. | Job | 1 | 6240000 | 6240000 | |
| 1331 | Light Fixtures | ||||||
| 1332 | Ref. Specs Sec. 8001, 8150 | ||||||
| 1333 | Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details. | ||||||
| 1334 | NS-15 | 10 W LED Flood light with bult in integrated driver and frosted glass diffuser IP 65 | No. | 10 | 5600 | 56000 | |
| 1335 | NS-16 | 200 W LED Flood light with bult in integrated driver and frosted glass diffuser IP 65 | No. | 60 | 55000 | 3300000 | |
| 1336 | NS-17 | Outdoor type LED Bollard light of minimum 1800 lumens light output, IP-55 or better rated | No. | 40 | 25000 | 1000000 | |
| 1337 | LOW VOLTAGE D.G. SET Ref. Spec. Sec. 8001, 8111, 8240. | ||||||
| 1338 | NS-28 | Supply, installation , testing and commissioning of 300 kVA, Prime Rating 415 volt D.G. Set skid mounted including control / Instrument Panels, generator Panel, fuel day tank and all accessories along with Sound proof Canopy, manufactured for 300 kVA Prime D.G. Set. etc. complete in all respect including factory testing expenditure as mentioned in Clause 13 of Section 8001. | Job. | 1 | 23700000 | 23700000 | |
| 1339 | **FIREFIGHTING WORKS** | ||||||
| 1340 | **Schedule Items** | ||||||
| 1341 | **BILLIARD ROOM** | ||||||
| 1342 | 23 / 54 | Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge: | |||||
| 1343 | i) | Dry Chemical Powder capacity 6 Kg | Each | 1 | 13329.6 | 13329.6 | |
| 1344 | ii) | CO2 Capacity 5 kg. | Each | 1 | 33067.2 | 33067.2 | |
| 1345 | **CAFÉ / CIGAR ROOM** | ||||||
| 1346 | 23 / 54 | Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge: | |||||
| 1347 | i) | Dry Chemical Powder capacity 6 Kg | Each | 2 | 13329.6 | 26659.2 | |
| 1348 | ii) | CO2 Capacity 5 kg. | Each | 2 | 33067.2 | 66134.4 | |
| 1349 | iv) | K-Type wet chemical capacity 6 Litters. | Each | 2 | 48232.8 | 96465.6 | |
| 1350 | **SWIMMING POOL** | ||||||
| 1351 | 23 / 54 | Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge: | |||||
| 1352 | i) | Dry Chemical Powder capacity 6 Kg | Each | 3 | 13329.6 | 39988.8 | |
| 1353 | ii) | CO2 Capacity 5 kg. | Each | 2 | 33067.2 | 66134.4 | |
| 1354 | **Non-Schedule Items** | ||||||
| 1355 | **PUMPING MACHINERY** | ||||||
| 1356 | NS-01 | Automatically operated submersible drainage pump set to be installed in Basement-sump pit, comprising 01No. pump (minimum particle passage : 25mm) including all accessories, pulling chain, Motor Control panel, level switches, gate valves, non return valves, manual tools spare parts, complete in all respects as per drawings and specs of approved make, pump of the following capacity and pumping head. Capacity = 30 gpm Head =02Bars | Job | 1 | 708000 | 708000 | |
| 1357 | **PEDAL COURT** | ||||||
| 1358 | **ELECTRICAL WORKS-BUILDING** | ||||||
| 1359 | **Non-Schedule Items** | ||||||
| 1360 | NSI-01 | Providing and Supplying Electricity and Lights Wiring with 7/29 Guage Wire (Pakistan Cable/Fast Cable) 4 x Lights 350 watts each Philips Lumileds Luxeon 3030 2D Model Life Span of PCB: 50,000hrs Light Source Efficiency (Im/w): 210lm/w Driver Brand: Philips IP Class: Module IP 66 complete in all respects. | No | 4 | 165938 | 663752 | |
| 1361 | **BOX CRICKET /FUTSAL GROUND** | ||||||
| 1362 | **ELECTRICAL WORKS-BUILDING** | ||||||
| 1363 | **Non-Schedule Items** | ||||||
| 1364 | NSI-05 | Providing and Supplying Electricity and Lights Wiring with 7/29 Gauge Wire (Pakistan Cable/Fast Cable) Lights 200 watts each Philips Lumileds Luxeon 3030 2D Model Life Span of PCB: 50,000hrs Light Source Efficiency (Im/w): 210 lm/w Driver Brand: Philips IP Class: Module IP 66 complete in all respects. | No | 14 | 39515 | 553210 | |
| 1365 | ** PROVISIONAL SUM ** | ||||||
| 1366 | Lump Sum Provision | 100000000 | 100000000 | ||||
| GRAND TOTAL: | Rs 496,583,040.16 |
All componenets in accordance with BOQ
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
Red Book:
© FIDIC 2017. All rights reserved.
The Conditions of Contract are the “General Conditions” which form part of the “Conditions of Contract for Construction for Building and Engineering Works Designed by the Employer (“Red book”) Second edition 2017” published by the Federation Internationale Des Ingenieurs – Conseils (FIDIC) and the following “Particular Conditions” which shall complement the General Conditions of the Contract.
The successful Bidder, upon contract award, shall be required to furnish two (02) copies of aforementioned “General Conditions” for incorporation in the Works Contract.
International Federation of Consulting Engineers (FIDIC) FIDIC
Bookshop – Box- 311 – CH – 1215 Geneva 15, Switzerland
Fax: +41 22 799 49 054
Telephone: +41 22 568 0500
E-mail: fidic@fidic.org
Website: www.fidic.org
FIDIC code: ISBN13: 978-2-88432-084-9
Particular Conditions
(Mandatory Provisions not to be amended/substituted)
The Particular Conditions (PCC) complement the General Conditions (GCC) to specify dates, contractual requirements, and special circumstances related to the Works. The PCC consists of two parts, Part A - Contract Data and Part B - Special Provisions. The provisions to be found in the Special Provisions (Particular Conditions - Part B) take precedence over the equivalent provisions found under the same Sub-Clause number(s) in the General Conditions, and the provisions of the Contract Data (Particular Conditions - Part A) take precedence over the Special Provisions (Particular Conditions - Part B).
Sub-Clause 1.1.27
Defects Notification Period (DNP): 365 Days
Sub-Clause 1.1.31
Employer's name & address: Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
Sub-Clause 1.1.35
Engineer's name & address: Concerned Member
Executive Block, CDA Secretariat G-7/4, Islamabad
Sub-Clause 1.1.84
Time for Completion: 120 days for whole of the works
Sub-Clause 1.3 (a)(ii)
Agreed method of electronic transmission: Not Agreed
Sub-Clause 1.3 (d)
Address of Empoyer for Communications: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
Address of Engineer for Communications:
Executive Block, CDA Secretariat G-7/4, Islamabad
Sub-Clause 1.4
Contract shall be governed by the law of: Islamic Republic of Pakistan
Ruling language: English
Language for communications: English
Sub-Clause 2.1
After receiving the Letter of Acceptance, the Contractor shall be given right of access to all or part of the Site within: 14 days after Commencement Date
Sub-Clause 2.4
Employer’s financial arrangements:
Through CDA's own resources
Sub-Clause 3.2 (e)(ii)
Engineer’s Duties and Authority: Variation resulting in an increase of the Accepted Contract Amount in excess ofone percent (1%)subject to accumulative Variations not exceeding five percent (5%)of the Accepted Contract Amount
Sub-Clause 4.2
Performance Security (as percentage of the Accepted Contract Amount in Currencies): 10.00%
Form of Performance Guarantee: Bank Guarantee
Sub-Clause 4.2.1
List of Insurance Companies:
Only Bank Guarantee
Sub-Clause 4.7.2
period for notification of errors in the items of reference: Twenty Eight (28) days
Sub-Clause 4.19
Period of payment for temporary utilities: Each Month
Sub-Clause 5.1 (a)
Maximum allowable accumulated value of work subcontracted (as a percentage of the Accepted Contract Amount): Nil %
Sub-Clause 5.1 (b)
Parts of the Works for which subcontracting is not permitted: Nil
Sub-Clause 6.5
Normal working hours on the Site: 8
Sub-Clause 8.3
Number of additional paper copies of programmes: 3
Sub-Clause 8.8 & 14.15(b)
Delay Damages payable for each day of delay 0.10% of the Accepted Contract Amountfor delay in completion of whole of the Works
Sub-Clause 8.8
Maximum amount of Delay Damages 10.00 % of the Accepted Contract Amount
Sub-Clause 8.14
Applicability of Incentives for Early Completion No
Sub-Clause 12.3
Percentage profit (Not more than 10%): Nil
Sub-Clause 13.4.(b)(ii)
Percentage rate to be applied to Provisional Sums for overhead charges and profit: Twenty Five percent (25%)
Sub-Clause 14.2
Total Advance Payment: Fifteen percent (15%) of the Accepted Contract Amount excluding Provisional Sums payable in the currencies and proportions in which the Accepted Contract Amount is payable
Sub-Clause 14.2.1
Advance Payment Insurance Not Allowed
Sub-Clause 14.2.3
Percentage deductions for the repayment of the Advance Payment: Deduction shall be made at the amortization rate of 17.5 % of the value of the Works executed of each IPC as provided in paragraph (i) of Sub-Clause GCC 14.3, starting from 2nd IPC provided that the advance payment shall be completely repaid prior to the time when 90% of the Accepted Contract Amount less Provisional Sums has been certified for payment. It may be more than 17.5% in the last instalment to ensure full repayment.
Sub-Clause 14.3
Period of payment One Month
Sub-Clause 14.3(b)
Number of additional paper copies of Statements: 3
Sub-Clause 14.3 (iii)
Percentage of retention: Seven percent (7%)
Sub-Clause 14.3 (iii)
Limit of Retention Money (as a percentage of the Accepted Contract Amount): Five percent (5%)
Sub-Clause 14.5(b)(i)
Plant and Materials for payment when shipped: Plant and Materials under Bill of “Imported Plant and Materials”
Sub-Clause 14.5(c)(i)
Plant and Materials for payment when delivered to the Site: Plant and Non Perishable Materials
Sub-Clause 14.6.2
Minimum amount of Interim Payment Certificate (IPC): Yes
The Minimum Amount IPC is 15000000
[Employer to give value not exceeding one fifth of the average expected value of Interim Payment Certificate]
Sub-Clause 14.7(a)
Period of payment of Advance Payment to the Contractor: 14 days
Sub-Clause 14.7b(i)
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.6: 28 days
Sub-Clause 14.7b(ii)
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.13 (Final Payment): 28 days
Sub-Clause 14.7(c)
Period for the Employer to make final payment to the Contractor: 56 days
Sub-Clause 14.8
Financing charges for delayed payment Local Currency (PKR):
6-Month KIBOR (Offer) +3% per annum.
Foreign Currency:
USD
6-Month SOFR (Secured Overnight Financing Rate for USD) +1% per annum.
EURO
6-Month EURIBOR (EURO Interbank Offered Rate for EURO) +1% per annum.
Others
Appropriate rates +1% (for other foreign currencies, Ref. Schedule-A, A-4 to Bid).
Sub-Clause 14.11.1(b)
Number of additional paper copies of draft Final Statements: 3
[insert number of copies say six (06)]
Sub-Clause 14.15
Currencies of payment of Contract Price: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(a)(i)
Proportions or amounts of Local and Foreign currencies: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(c)
Currencies and proportions for payment of Delay Damages: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)
Sub-Clause 14.15(f)
rates of exchange: as stated in the Table IV of Schedule A (If Given)
Sub-Clause 17.2(d)
Forces of nature, the risks of which are allocated to the Contractor: Nil
Sub-Clause 19.1
Permitted deductible limits:
i) insurance required for the Works: Ten percent (10%) of loss amount on each & every loss
ii) insurance required for Goods: Nil
iii) insurance required for liability for breach of professional duty: Nil
iv) insurance required against liability for fitness for purpose (if any is required): Nil
v) insurance required for injury to persons and damage to property: Nil
vi) insurance required for injury to employees: Nil
vii) other insurances required by Laws and by local practice : Nil
Periods for submission of insurance:
a) evidence of insurance: Not later than the Commencement Date
b) relevant policies: Within twenty eight (28) day from the Commencement Date
Sub-Clause 19.2.1(b)
Additional amount to be insured (as a percentage of the replacement value): 15% of the replacement value (Accepted Contract Amount)
Sub-Clause 19.2.2
Extent of insurance required for Goods: From Ex-Works (i.e., works, factory, warehouse, etc) to delivery at the Site
Amount of insurance required for Goods: Full replacement value
Sub-Clause 19.2.3(a)
Amount of insurance required for liability for breach of professional duty: Full replacement value of the Works to be designed by the Contractor
Sub-Clause 19.2.3(b)
Insurance required against liability for fitness for purpose: Yes
Sub-Clause 19.2.3
Period of insurance required for liability for breach of professional duty: Until the date of issuance of Performance Certificate
Sub-Clause 19.2.4
Amount of insurance required for injury to persons and damage to property: Injury to person and Fatal case:
in accordance with Workmen Compensation Act
Damage to Property: The Amount of Insurance Required for Person Injury is 2000000
The Amount of Insurance Required for Damage to Property is 5000000 as per his assessment of the adjoining property(ies) other than the Works]
without limit to the number of incidents
Sub-Clause 19.2.6
Other insurances required by Laws and by local practice: All insurances as applicable, to the extent of execution of the project, under Federal and Provincial laws of Islamic Republic of Pakistan
Sub-Clause 21.1
Time for appointment of the DAAB: Within 28 days from the Commencement Date.
In case the Accepted Contract Amount is lesser than PKR one (01) billion, appointment of the DAAB shall be made when Dispute arises between the Parties.
Sub-Clause 21.1
The DAAB shall comprise 1
[insert either “a sole Member” or “Three Members”]
[For a Contract estimated to cost above PKR 2.5billion, the DAAB shall comprise of three members. For a Contract estimated to cost between PKR1billion and PKR2.5billion, the DAAB may comprise of three members or a sole member. For a Contract estimated to cost less than PKR1billion, a sole member is recommended.]
Sub-Clause 21.1
List of proposed members of DAAB
- proposed by Employer
Dr. Shahid Mehmood
Sub-Clause 21.2
Appointing entity (official) for DAAB members Managing Director Public Procurement Regulatory Authority (PPRA) or Chairman Pakistan Engineering Council (PEC) from the list of PEC approved arbitrators published at its website
Sub-Clause 21.6
Rules of Arbitration: PEC Rules of Conciliation and Arbitration or Pakistan Arbitration Act of 1940, if the former is inactive.
The place of Arbitration shall be in the Employer’s country: Islamabad , Pakistan
[Insert name of city]
PartB - Special Provisions
1.1 Definitions
1.1.76 “Specification”
Following is added at the end:
“and consists of two parts i.e.,
i) “Part A - Specific Provisions”; and
ii) “Part B - Technical Provisions”.”
1.2 Interpretation
“and” is deleted from the end of sub-paragraph (i) and added at the end of sub-paragraph (j).
Sub-paragraph (k) is added:
“(k) The word “tender” is synonymous with “bid” the word tenderer with “bidder”, the words “tender documents” with “bidding documents” and “Schedule of Prices” with “Bill of Quantities”, as applicable.”
1.5 Priority of Documents The documents listed at (a) through (k) of this Sub-Clause are deleted and substituted with the following:
(a) the Contract Agreement;
(b) the Letter of Acceptance;
(c) the Letter of Bid;
(d) the Particular Conditions Part A - Contract Data;
(e) the Particular Conditions Part B - SpecialProvisions;
(f) the General Conditions;
(g) the Specification Part A - SpecificProvisions;
(h) the Specification Part B- Technical Provisions;
(i) the Drawings;
(j) the completed Schedules to Bid includingBillof Quantities;
(k) the JV Undertaking (if the Contractor is a JV); and
(l) any other documents forming part of the Contract.
The addenda/corrigenda, if any, shall be deemed to have been incorporated at the appropriate places in the documents forming the Contract.
1.6 Contract Agreement
In the last line of the 1st paragraph the text “shall be borne by the Employer” is substituted by “shall be reimbursed by the Employer to the Contractor”.
3.1 The Engineer
In sub-paragraph (a) the text “as defined in the Pakistan Engineering Council Act, 1975 (Act No.V of 1976)” are added after the words “professional engineer”.
3.2 Engineer’s Duties and Authority
The Engineer shall obtain the consent in writing of the Employer before taking action under the following Sub-Clauses of these Conditions:
(a) Consenting to the subcontracting of any part of the Works under Sub-Clause 5.1 [Subcontractors]
(b) Any action under Sub-Clauses 8.9 [Employer’s Suspension] and 8.12 [Prolonged Suspension]
(c) Issuance of “Taking Over Certificate” under Sub-Clause 10.1 [Taking Over the Works and Sections].
(d) Issuing the “Performance Certificate” under Sub-Clause 11.9 [Performance Certificate].
(e) Sub-Clause 13.1 [Right to Vary]: instructing a Variation, except;
(i) in an emergency situation as determined by the Engineer, or
(ii) if such a Variation would increase the Accepted Contract Amount by less than the percentage specified in the Contract Data.
(f) Sub-Clause 13.3 [Variation Procedure]: approving a proposal for Variation submitted by the Contractor in accordance with Sub-Clause 13.3.2 [Variation by Request for Proposal] or 13.2 [Value Engineering].
(g) Certifying release of second half of the Retention Money under Sub-Clause 14.9 [Release of Retention Money].
(h) Issuing Final Payment Certificate under Sub-Clause 14.13 [Issue of FPC].
(i)
Determination
4.2 Performance Security
4.2.1 Contractor’s Obligations
The entity issuing the Performance Security and its form shall be as under:
The Performance Security shall be, at the option of the Contractor,issuedin the prescribed form included in the Bidding Documents,by(a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistan or (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofratingas provided in Table below:
Accepted Contract Amount (In Eq. PKR million) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
In case of Joint Venture, the Performance Security shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.
Following paragraph is added at the end of this Sub-Clause:
“The amount of Performance Security shall be reducedto 50%following issue of the Taking-Over Certificate for the whole of the Works under Clause 10 of Conditions of Contract.”
4.3 Contractor’s Representative
In second paragraphthe text “professional engineer as defined in the Pakistan Engineering Council Act, 1975 (Act No. V of 1976) (having temporary licence in case of foreign engineer under Section 12 of the Pakistan Engineering Council Act, 1975 (Act No. V of 1976)” are added after the words “qualified, experienced”.
In the 3rd paragraph the words “28 days” are substituted by “14 days”. In 2nd line of 4thparagraph the text “or appoint a replacement” is substituted by “except appointment of a suitable temporary replacement is deployed at the Site”
4.4 Contractor’s Documents
4.4.2 As-Built Records
First paragraph is deleted and the text in the last paragraph is substituted with the following:
“The Contractor shall furnish to the Engineer 6 copies, one reproducible and one electronic copy(provided the Engineer has made available to the Contractor editable form of the Drawings)of all Drawings amended to conform to the Works as built.In case the Engineer does not make available to the Contractor editable form of the Drawings, the Contractor shall furnish to the Engineer as-built data for incorporation in the Drawings. Upon receipt of PDF versions of the as-built drawings prepared by the Engineer, the Contractor shall furnish to the Engineer 6copies and one reproducible of these Drawings.
The price of such Drawings shall be deemed to be included in the Contract Price.”
Following Sub-Clause is added:
4.4.4 ShopDrawings
The Contractor shall submit to the Engineer for review 3 copies of all shop and erection drawings applicable to this Contract as per provision of relevant Sub-Clause of the Contract.
Review and approval by the Engineer shall not exceed 21 days and be construed as a complete check but will indicate only that the general method of construction and detailing is satisfactory and the Engineer’s review or approval shall not relieve the Contractor of any of his responsibilities under the Contract.
4.8 Health and Safety Obligations
The following text is added at the end ofthis Sub-Clause:
In the event of work being carried out outside the normal working hours and in the event of work being carried out at night, the Contractor shall at his own cost, provide and maintain such good and sufficient light as will enable the work to proceed satisfactorily and without danger. The approaches to the Site and the Works where the night work is being carried out shall be sufficiently lighted. All arrangement adopted for such lighting shall be to the satisfaction of the Engineer.
4.20 Progress Reports
At the end of sub-paragraph (g) the word “and” is deleted and at the end of sub-paragraph (h) the full stop (.) is replaced with “;”, and the following new sub-paragraphs are added as:
(i) planned programme for the execution of the Works for next 56 days to enable the Engineer to determine its programme of inspection and testing;
(j) monthly summery of daily job record indicating weather conditions, deployment of Contractor’s Equipment, labour employment, local material procurement and material import, if any; and
(k) salient contractual and project information.
5.1 Subcontractors
Add the following text at the end of paragraph (ii):
“underSchedule to Bid”
The following is added at the end of the last paragraph of Sub-Clause 5.1:
“All subcontracts relating to the Works shall include provisions which entitle the Employer to require the subcontract to be assigned to the Employer under sub-paragraph (a) of Sub-Clause 15.2.3 [After Termination].
The Contractor shall give reasonable opportunity to contractors from Islamic Republic of Pakistan for subcontracts for the Works, and endeavour to employ such contractors as Subcontractors.”
5.2 Nominated Subcontractors
5.2.2 Objection to Nomination
In sub-paragraph (c), “and” is deleted from the end of (i);
“.” at the end of (ii) is replaced with: “, and”.
The following is then added as (iii):
“(iii) be paid only if and when the Contractor has received from the Employer payments for sums due under the Subcontract referred to under Sub-Clause 5.2.3 [Payment to nominated Subcontractors].”
6.1 Engagement of Staff and Labour
The following paragraph is added at the end of the Sub-Clause:
“The Contractor shall, to the extent practicable and reasonable, employ staff (not less than 50%) and labour (not less than 85%) with appropriate qualifications and experience from sources within the Islamic Republic of Pakistan.”
6.7 Health and Safety of Personnel
The existing text is substituted with the following:
“In order to provide for the safety, health and welfare of persons, and for prevention of damage of any kind, all operations for the purposes of or in connection with the Contract shall be carried out in compliance with the Safety Requirements of the Government of Pakistan with such modifications thereto as the Engineer may authorize or direct and the Contractor shall take or cause to be taken such further measures and comply with such further requirements as the Engineer may determine to be reasonably necessary for such purpose. The Contractor shall also provide all other medical services and appoint a health and safety officer at Site if stated in the Specifications. In case of any fatality or serious accident, the Contractor shall, in addition, notify the Engineer immediately by the quickest available means.”
6.8 Contractor’s Superintendence
Insert at the end of sub-paragraph (a) of this Sub-Clause:
"or, if not, the Contractor shall make competent interpreters available during all working hours, in a number sufficient for those persons to properly perform their superintendence duties"
The following text is added at the end of this Sub-Clause:
“The Contractor’s authorized representative and his other engineers working at site shall possess valid registration with the Pakistan Engineering Council.
The Contractor’s authorized representative at Site shall be authorized to exercise adequate administrative and financial powers on behalf of the Contractor so as to achieve completion of the Works as per the Contract.”
6.12 Key Personnel
The following is inserted at the end of the last paragraph:
“If any of the Key Personnel are not fluent in this language, the Contractor shall make competent interpreters available during all working hours in a number deemed sufficient by the Engineer.”
The following Sub-Clauses 6.13 to 6.26 are added at the end of Sub-Clause 6.12:
6.13 Foreign Personnel
The Contractor may bring in to the Country any foreign personnel who are necessary for the execution of the Works to the extent allowed by the applicable Laws. The Contractor shall ensure that these personnel are provided with the required residence visas and work permits. The Employer will, if requested by the Contractor, use all reasonable endeavours in a timely and expeditious manner to assist the Contractor in obtaining any local, state, national, or government permission required for bringing in the Contractor’s personnel.
The Contractor shall be responsible for the return of these personnel to the place where they were recruited or to their domicile. In the event of the death in the Country of any of these personnel or members of their families, the Contractor shall similarly be responsible for making the appropriate arrangements for their return or burial.
6.14 Supply of Foodstuffs
The Contractor shall arrange for the provision of a sufficient supply of suitable food as may be stated in the Specification at reasonable prices for the Contractor’s Personnel for the purposes of or in connection with the Contract.
6.15 Supply of Water
The Contractor shall, having regard to local conditions, provide on the Site an adequate supply of drinking and other water for the use of the Contractor’s Personnel.
6.16 Measures against Insect and Pest Nuisance
The Contractor shall at all times take the necessary precautions to protect the Contractor’s Personnel employed on the Site from insect and pest nuisance, and to reduce the danger to their health. The Contractor shall comply with all the regulations of the local health authorities, including use of appropriate insecticide.
6.17 Alcoholic Liquor or Drugs
The Contractor shall not, otherwise than in accordance with the Laws of the Country, import, sell, give, barter or otherwise dispose of any alcoholic liquor or drugs, or permit or allow importation, sale, gift, barter or disposal thereto by Contractor’s Personnel.
6.18 Arms and Ammunition
The Contractor shall not give, barter, or otherwise dispose of, to any person, any arms or ammunition of any kind, or allow Contractor’s Personnel to do so.
6.19 Festivals and Religious Customs
The Contractor shall respect the Country’s recognized festivals, days of rest and religious or other customs.
6.20 Funeral Arrangements
The Contractor shall be responsible, to the extent required by local regulations, for making any funeral arrangements for any of its local employees who may die while engaged upon the Works.
6.21 Forced Labour
The Contractor, including its Subcontractors, shall not employ or engage forced labour which consists of any work or service, not voluntarily performed, that is exacted from an individual under threat of force or penalty, and includes any kind of involuntary or compulsory labour, such as indentured labour, bonded labour or similar labour-contracting arrangements.
6.22 Child Labour
The Contractor, including its Subcontractors, shall not employ or engage child labour in accordance with relevant law(s) in force in Islamic Republic of Pakistan.
6.23 Employment Records of Workers
The Contractor shall keep complete and accurate records of the employment of labour at the Site. The records shall include the names, ages, genders, hours worked and wages paid to all workers. These records shall be summarized on a monthly basis and submitted to the Engineer. These records shall be included in the details to be submitted by the Contractor under Sub-Clause 6.10 [Contractor’s Records].
6.24 Workers’ Organizations
The Contractor shall comply with the relevant labour laws of Pakistan which recognize workers’ rights to form and to join workers’ organizations/Trade Union of their choosing and to bargain collectively without interference.
6.25 Non-Discrimination and Equal Opportunity
The Contractor shall not make decisions relating to the employment or treatment of Contractor’s Personnel on the basis of personal characteristics unrelated to inherent job requirements. The Contractor shall base the employment of Contractor’s Personnel on the principle of equal opportunity and fair treatment, and shall not discriminate with respect to any aspects of the employment relationship, including recruitment and hiring, compensation (including wages and benefits), working conditions and terms of employment, access to training, job assignment, promotion, termination of employment or retirement, and disciplinary practices.
Special measures of protection or assistance to remedy past discrimination or selection for a particular job based on the inherent requirements of the job shall not be deemed discrimination. The Contractor shall provide protection and assistance as necessary to ensure nondiscrimination and equal opportunity, including for specific groups such as women, persons with disabilities, migrant workers and children (of working age in accordance with Sub-Clause 6.22).
6.26 Epidemics
In the event of any out-break of illness of epidemic nature, the Contractor shall comply with and carry out such regulations, orders and requirements as may be made by the Government or the local medical or sanitary authorities for the purpose of overcoming the same.
7.7 Ownership of Plant and Materials
The following is added before the first paragraph:
“Except as otherwise provided in the Contract,”
The following is added at the end of the Sub-Clause:
"No Plant and/or Materials that is the property of the Employer shallbe removed from the Site. If it becomes necessary to:
(i) remove any item of such Plant from the Site for the purposesof repair, the Contractor shall give a Notice, with reasons, tothe Engineer requesting consent to remove the defective ordamaged item off the Site. This Notice shall clearly identifythe item of defective or damaged Plant, and shall give detailsof: the defect or damage to be repaired; the place to whichdefective or damaged item of Plant is to be taken for repair;the transportation to be used (and insurance cover for suchtransportation); the proposed inspections and testing off theSite; and the planned duration required before the repaireditem of Plant shall be returned to the Site. The Contractorshall also provide any further details that the Employer mayreasonably require; or
(ii) replace any item(s) of such Plant and/or Materials, theContractor shall give a Notice, with reasons, to the Engineerclearly identifying the item(s) of Plant and/or Materials to bereplaced, and giving details of the due date of delivery tothe Site of the replacement item(s).
Where any item of Plant and/or Materials has become the propertyof the Employer under this Sub-Clause before it has been deliveredto the Site, the Contractor shall ensure that such an item is notmoved except for its delivery to the Site.
The Contractor shall indemnify and hold the Employer harmlessagainst and from the consequences of any defect in title orencumbrance or charge (except any reasonable restrictionarising from the intellectual property rights of the manufacturer orproducer) on any item of Plant and/or Materials that has becomethe property of the Employer under this Sub-Clause."
The following Sub-Clause7.9 is added after Sub Clause 7.8:
7.9 Use of Pakistani Materials and Services
The Contractor shall, so far as may be consistent with the Contract, make the maximum use of materials, supplies, plant and equipment indigenous to or produced or fabricated in Pakistan and services available in Pakistan provided such materials, supplies, plant, equipment and services shall be of required standard.
8.1 Commencement of Works
The following is added before the first paragraph:
“After signing of the Contract Agreement by both Parties,” and thereafter the word “The” is replaced with the word “the”.
8.5 Extension of Time for Completion
The following is added after paragraph (c):
“for last five years”.
The following Sub-Clause 8.14 is added after Sub-Clause 8.13:
8.14 Incentives For Early Completion
If Contract Data does not state applicability of incentives for early completion, this Sub-Clause shall not apply.
The Contractor shall be entitled subject to Sub-Clause 20.2 [Claims for Payment and/or EOT] to bonus payment if the Works and/or each Section is completed earlier than the Time for Completion for the Works or Section (as the case may be). The amount of bonus for early completion of the Works and/or each Section shall be upto a limit and at a rate to 50% of the relevant limit and rate of delay damages prescribed in Contract Data and shall be paid for every day which shall elapse between the relevant Date of Completion of the Works or Section and the relevant Time for Completion.
For the purposes of calculating any bonus payment, the applicableTime for Completion stated in the Contract Data is fixed and noadjustments of this time by reason of granting an EOT will beallowed.
The following Sub-Clause 11.12 is added after Sub-Clause 11.11:
11.12 Supervisory Assistance During DNP
If provided under the Schedule of Prices, the Contractor shall provide supervisory assistance to the Employer during the DNP for the Works. Such supervisory assistance shall be as described in the Specification for the purpose of supporting the Employer's operation and maintenance of the Plant for the period specified in the Schedule of Prices after the Date of Completion.
12.2 Method of Measurement
The following paragraph is added at the end of the Sub-Clause:
“Summary of measured quantity for payment shall be delineated item-wise under four headsnamely; “Schedule of Prices Quantity”, “Quantity Executed To-date”, “Quantity Certified Previously” and “Net Quantity Executed under this Certificate”.
12.3 Valuation of the Works
The following text is added at the end of fifth paragraph of the Sub-Clause:
“Sum of overhead charges and profit for sub-paragraph (a) shall be Twenty Five percent (25%)”.
13.4 Provisional Sums
The following paragraph is inserted as the penultimate paragraph:
“The Provisional Sum shall be used to cover the Employer’s share of the DAAB members’ fees and expenses, in accordance with Clause 21. No prior instruction of the Engineer shall be required with respect to the work of the DAAB. The Contractor shall submit the DAAB members’ invoices and the satisfactory evidence of having paid 100% of such invoices as part of the substantiation of those Statements submitted under Sub-Clause 14.3.
13.6 Adjustments for Changes in Laws
The following paragraphsare added at the end of the Sub-Clause:
“Notwithstanding the foregoing, the Contractor shall not be entitled to an extension of time if the relevant delay has already been taken into account in the determination of a previous extension of time and such Cost shall not be separately paid if the same shall already have been taken into account in the indexing of any inputs to the Table of Adjustment Data in accordance with the provisions of Sub-Clause 13.7 [Adjustments for Changes in Cost].”
14.1 The Contract Price
The following is added at the end of the Sub-Clause:
“Notwithstanding the provisions of subparagraph (b), Contractor's Equipment, including essential spare parts, imported by the Contractor for the sole purpose of executing the Contract shall be temporarily exempt from the payment of import duties and taxes upon initial importation, provided the Contractor shall post with the customs authorities at the port of entry an approved re-export bond or bank guarantee, valid until the Time for Completion plus six months, in an amount equal to the full import duties and taxes which would be payable on the assessed imported value of such Contractor's Equipment and spare parts, and callable in the event the Contractor's Equipment is not re-exported from the Country on completion of the Contract. A copy of the bond or bank guarantee endorsed by the customs authorities shall be provided by the Contractor to the Employer upon the importation of individual items of Contractor's Equipment and spare parts. Upon re-export of individual items of Contractor's Equipment or spare parts, or upon the completion of the Contract, the Contractor shall prepare, for approval by the customs authorities, an assessment of the residual value of the Contractor's Equipment and spare part to be re-exported, based on the depreciation scale(s) and other criteria used by the customs authorities for such purposes under the provisions of the applicable Laws. Import duties and taxes shall be due and payable to the customs authorities by the Contractor on (a) the difference between the initial imported value and the residual value of the Contractor's Equipment and spare parts to re-exported; and (b) on the initial imported value of the Contractor's Equipment and spare parts remaining in the Country after completion of the Contract. Upon payment of such dues within 28 days of being invoiced, the bond or bank guarantee shall be reduced or released accordingly; otherwise the security shall be called in the full amount remaining.”
[The Employer may change or delete this Sub-Clause as per Project requirements]
14.2 Advance Payment
14.2.1 Advance Payment Guarantee
The entity issuing the Advance PaymentGuaranteeand its form shall be as under:
The Advance PaymentGuarantee shall be in the form of Guarantee issued by (a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistanor (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofrating as provided in Table below:
Accepted Contract Amount (In Eq. million PKR) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
In case of Joint Venture, the Advance PaymentGuarantee(s)shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.
14.6 Issue of IPC
14.6.1 The IPC
In the first line of the 1st paragraph the words “28 days” are substituted by “14 days”.
14.7 Payment
The words “or through crossed cheque in favour of the Contractor or JV partners. The Payment to JV partners shall be made at the request of the Joint Ventures in the ratio of their shares specified by them” are added at the end of the Sub-Clause.
14.8 Delayed Payment
In the first paragraph, third line, the words “compounded monthly” are deleted.
The text of 2nd paragraph is deleted and substituted with the following:
“The Employer shall pay to the Contractor compensation at the rate stated in the Contract Data.”
14.9 Release of Retention Money
The following is added at the end of Sub-Clause 14.9:
“Unless otherwise stated in the Contract, when the Taking-Over Certificate has been issued for the Works and the first half of the Retention Money has been certified for payment by the Engineer, the Contractor shall be entitled to substitute a guarantee, in the form annexed to the Particular Conditions or in another form approved by the Employer and issued by a schedule bank selected by the Contractor, for the second half of the Retention Money. The Contractor shall ensure that the guarantee is in the amounts and currencies of the second half of the Retention Money and is valid and enforceable until the Contractor has executed and completed the Works and remedied any defects, as specified for the Performance Security. On receipt by the Employer of the required guarantee, the Engineer shall certify, and the Employer shall pay the second half of the Retention Money. The release of the second half of the Retention Money against a guarantee shall then be in lieu of the release after the latest of the expiry dates of the Defects Notification Periods. The Employer shall return the guarantee to the Contractor within 21 days after receiving a copy of the Performance Certificate.
If the Performance Security required under Sub-Clause 4.2 is in the form of a demand guarantee, and the amount guaranteed under them when the Taking-Over Certificate is issued is more than half of the Retention Money, then the Retention Money guarantee will not be required. If the amount guaranteed under the Performance Security when the Taking-Over Certificate is issued is less than half of the Retention Money, the Retention Money guarantee will only be required for the difference between half of the Retention Money and the amount guaranteed under the Performance Security.
15.2 Termination for Contractor’s Default
15.2.1 Notice
Following text is added at the end of sub-paragraph (h) of this Sub-Clause:
“For the purposes of this Contract, corrupt and fraudulent practices have been defined in Public Procurement Rules 2004.”
15.2.3 After Termination
The word “and” at the end of sub-paragraph (ii) of paragraph (b) is deleted the following paragraph is added after sub-paragraph (iii):
“(iv) all Employer-Supplied Materials and/or Employer's Equipment madeavailable to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer's Equipment], and”
15.4 Payment after Termination
The following text is added at the end of this Sub-Clause:
“The Employer shall be entitled to sell any of the Contractor’s Equipment, Temporary Works and unused materials and apply the proceeds of sale towards payment of any debt due from the Contractor to the Employer under this Clause including any outstanding payments to the Subcontractors.
16.2 Termination by Contractor
16.2.1 Notice
The sub-paragraph (j) is deleted in its entirety.
At the end of sub-paragraph (i) “; or” is replaced with “.” and at the end of sub-paragraph (h) “;” is replaced with “; or”.
In sub-paragraph (f) “84 days” are replaced with “180 days” and text “for reasons not attributable to the Contractor” is added at the end.
16.3 Contractor’s Obligations After Termination
Sub-paragraph (c) is deleted and replaced with:
"(c) deliver to the Engineer all Employer-Supplied Materials and/orEmployer's Equipment made available to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer’s Equipment]; and
(d) remove all other Goods from the Site, except as necessary for safety,and leave the Site."
17.1 Responsibility for Care of the Works
After the two instances of “Goods” in the last paragraph, the words “Employer-Supplied Materials and/orEmployer's Equipment” are added.
The following Sub-Clause 17.7 is added after Sub-Clause 17.6:
17.7 Use of Employer’s Accommodation/Facilities
The Contractor shall take full responsibility for the care of the items of the Employer’s facilities and/or accommodation, if any, as detailed in the Specification, from the date of use and/or occupation by the Contractor until the date on which such use and/or occupation is re-vested in the Employer.
If any loss or damage happens to any of the above items during a time while the Contractor is responsible for its care, arising from any cause other than a cause for which the Employer is responsible or liable, the Contractor shall promptly rectify the loss or damage at the Contractor’s risk and cost.
18.1 Exceptional Events
The words “or disorder” are replaced with “disorder or sabotage” in sub-paragraph (c) of the Clause.
18.4 Consequences of an Exceptional Event
The following is added at the end of sub-paragraph (b) after deleting the “.”:
“, including the costs of rectifying or replacing the Works and/or Goods damaged or destroyed by Exceptional Events, to the extent they are not indemnified through the insurance policy referred to in Sub-Clause 19.2 [Insurance to be provided by the Contractor].”
18.5 Optional Termination
In sub-paragraph (c), the words “and necessarily” areadded after the words “was reasonably”.
19.1 General Requirements
Following text is added at the end of first paragraph:
“The Contractor shall immediately after the date of the Letter of Acceptance submit the draft of insurance policies for the Employer’s consent.”
Following text is added at the end of third paragraph:
“The Contractor shall, within the respective periods stated in the Contract Data submit to the Engineer and the Employer a) evidence that the insurances described in this Clause have been effected, and b) copies of policies of the insurances described in Sub-Clauses 19.2.1, 19.2.4 and 19.2.5.”
19.2 Insurance to be provided by the Contractor
19.2.5 Injury to employees
The words “sickness, disease” are deleted in the third line of first paragraph.
The following Sub-Clause is added after Sub-Clause 19.2.6:
19.2.7 Insurance Company
“The Contractor shall be obliged to place all insurances described in this Clause with insurers listed in the Contract Data and rated byPACRA/VISofrating as provided in Table below:
Accepted Contract Amount (In Eq. million PKR) Minimum Rating of Insurance Companies
Up to 1000 A (+)
1001 to no limit AA
21.6 Arbitration
The word “international” is deleted in the sixth line of first paragraph. The text of sub-paragraph (a) is substituted with the following:
“the Dispute shall be finally settled under the Rules of Arbitration, specified in the Contract Data;”
The following Clauses are added after Clause 21
22 Custom Duty
[Employer may incorporate provisions where applicable. However, in order to make the bid more balanced, the payment of Customs Duties should be the responsibility of the Employer.]
23 Taxes
The Contractor, Subcontractors and their employees shall be liable to pay income tax, withholding tax, super tax and other taxes on income arising out of the Contract. The rates and prices as stated in the contract shall be deemed to cover all such taxes.
24 Integrity Part
If it is found and established at any stage that the Contractor or any of his Subcontractors, agents or servants have violated or involved in violation of the Integrity Pact signed by the Contractor then the Employer shall be entitled to :
(a) recover from the Contractor an amount equivalent to ten times the sum of any commission, gratification, bribe, finder’s fee or kickback given by the Contractor or any of his Subcontractors, agent or servants;
(b) terminate the Contract; and
(c) recover from the Contractor any loss or damage to the Employer as a result of such termination or of any other corrupt business practices of the Contractor or any of his Subcontractors, agent or servants.
The termination under sub-paragraph(b) of this Sub-Clause shall proceed in the manner prescribed under Sub-Clause 15.1 to 15.4 and the payment under Sub-Clause 15.4 shall be made after having deducted the amounts due to the Employer under sub-paragraph(a) and (c) of this Sub-Clause.
Appendix General Conditions of Dispute Avoidance/Adjudication Agreement
12 Disputes Under DAAB Agreement
In the first paragraph, third, fourth and fifth line, the text “under the Rules of Arbitration of the International Chamber of Commerce 2017……………shall apply” is substituted with “under the Arbitration Act 1940 by sole arbitrator appointed by the Managing Director Public Procurement Regulatory Authority or Chairman Pakistan Engineering Council.”
Date:
No.:
Alternative No.: P63434
To: Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid-Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
(a) have withdrawn our Bid during the period of Bid validity specified in the Letter of Bid; or
(b) having been notified of the acceptance of our Bid by the Procuring agency/Employer during the period of Bid validity, (i) fail or refuse to sign the Contract; or (ii) fail or refuse to furnish the Performance Security (or guarantee), if required, in accordance with the ITB.
We understand this Bid Securing Declaration shall expire if we are not the successful Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight days after the expiration of our Bid.
Name of the Bidder*
Name of the person duly authorized to sign the Bid on behalf of the Bidder** _______
Title of the person signing the Bid ______________________
Signature of the person named above ______________________
Date signed ________________________________ day of ___________________, _____
*: In the case of the Bid submitted by joint venture specify the name of the Joint Venture as Bidder
**: Person signing the Bid shall have the power of attorney given by the Bidder attached to the Bid
[Note: In case of a Joint Venture, the Bid-Securing Declaration must be in the name of all members to the Joint Venture that submits the Bid.]
THIS CONTRACT AGREEMENT (hereinafter called the “Agreement”) made on the _________ day of __________ (month) 20_____ between Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad (hereinafter called the “Employer”) of the one part and __________________________________________________ (hereinafter called the “Contractor”) of the other part.
WHEREAS the Employer is desirous that certain Works, viz., WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD. (P63434) should be executed by the Contractor and has accepted a Bid by the Contractor for the execution and completion of such Works and the remedying of any defects therein.
NOW this Agreement witnessed as follows:
1. In this Agreement words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract hereinafter referred to.
2. The following documents, in the order of priority, after incorporating addenda, if any, except those parts relating to Instructions to Bidders shall be deemed to form and be read and construed as part of this Agreement:
a) This Contract Agreement;
b) The Letter of Acceptance;
c) The Letter of Bid;
d) The Particular Conditions Part A - Contract Data;
e) The Particular Conditions Part B - SpecialProvisions;
f) The General Conditions;
g) The Specifications Part A - SpecificProvisions;
h) The Specifications Part B- Technical Provisions;
i) The Drawings;
j) The Completed Schedules to Bid including Schedule of Prices;
k) the JV Undertaking (if the Contractor is a JV); and
l) [Employer to insert any other documents forming part of the Contract]
The addenda/corrigenda,if any, (Excluding part relating to Instructions to Bidders alongwith Bidding Data) shall be deemed to have been incorporated at the appropriate places in the “Documents forming the Contract”.
3. In consideration of the payments to be made by the Employer to the Contractor as hereinafter mentioned, the Contractor hereby covenants with the Employer to execute and complete the Works and remedy defects therein in conformity and in all respects with the provisions of the Contract.
4. The Employer hereby covenants to pay the Contractor, in consideration of the execution and completion of the Works as per provisions of the Contract, the Contract Price or such other sum as may become payable under the provisions of the Contract at the times and in the manner prescribed by the Contract.
IN WITNESS WHEREOF the parties hereto have caused this Agreement to be executed on the day, month and year first before written in accordance with their respective laws.
Signature of the Contactor Signature of Employer
(Seal) (Seal)
Signed, Sealed and Delivered in the presence of:
Witness Witness
(Name, Title and Address) (Name, Title and Address)
[All italicised text and any text within square brackets (except sub-clause headings) in this form of agreement is for use in preparing the form and should be deleted from the final product].
Name and details of the Contract WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.
______________________________________________________________________________
This Agreement made the ______day of ______ [month], _____ [year], between
Name and contact details of the Employer Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA
Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
+92-334-856-6622
ammarpavero@gmail.com
Name and contact details of the Contractor _____________________________________ (name)
____________________________________ (address)
__________________________________ (telephone)
___________________(email / other contact details);
Name and contact details of the DAAB Member _____________________________________ (name)
____________________________________ (address)
__________________________________ (telephone)
___________________(email / other contact details);
Whereas:
A. the Employer and the Contractor have entered (or intend to enter) into the Contract;
B. under the Contract, the “DAAB” or “Dispute Avoidance/Adjudication Board” means the sole member or three members (as stated in the Contract Data of the Contract) so named in the Contract, or appointed under Sub-Clause 21.1 [Constitution of the DAAB] or Sub-Clause 21.2 [Failure to Appoint DAAB Members] of the Conditions of Contract;
C. the Employer and the Contractor desire jointly to appoint the above-named DAAB Member to act on the DAAB as:
a. the sole member of the DAAB, and where this is the case, all references to the “Other Members” do not apply; or
b. one of three members / chairman [delete the one which is not applicable] of the DAAB and, where this is the case, the other two persons are:
____________________________ (name) _________________________ (name)
___________________________ (address) _______________________ (address)
_____________________________(telephone) ______________________(telephone)
______________(email/ other contact details) _______ (email/other contact details)
the “Other Members”; and
D. the DAAB Member accepts this appointment.
The Employer, Contractor and DAAB Member jointly agree as follows:
1. The conditions of this DAAB Agreement comprise:
(a) Clause 21 [Disputes and Arbitration] of the Conditions of Contract, and any other provisions of the Contract that are applicable to the DAAB’s Activities; and
(b) the “General Conditions of Dispute Avoidance/Adjudication Agreement”, which is appended to the General Conditions of the “Conditions of Contract for Construction” Second Edition 2017 published by FIDIC (“GCs”), as amended and/or added to by the following provisions.
2. [Details of amendments to the GCs, if any. For example:
In the procedural rules annexed to the GCs, Rule _ is deleted and replaced by: “ … “]
3. The DAAB Member shall be paid in accordance with Clause 9 of the GCs. The currency of payment shall be ________.
In respect of Sub-Clauses 9.1 and 9.2 of the GCs, the amounts of the DAAB Member’s monthly fee and daily fee shall be:
monthly fee___________________ per month, and
daily fee of____________________ per day
(or as otherwise set under Sub-Clause 9.3 of the GCs).
4. In consideration of the above fees, and other payments to be made to the DAAB Member in accordance with the GCs, the DAAB Member undertakes to act as DAAB Member in accordance with the terms of this DAAB Agreement.
5. The Employer and the Contractor shall be jointly and severally liable for the DAAB Member’s fees and other payments to be made to the DAAB Member in accordance with the GCs.
6. This DAAB Agreement shall be governed by the law of _____________ (if not stated, the law that governs the Contract under Sub-Clause 1.4 of the Conditions of Contract).
SIGNED by:_______________ SIGNED by:_______________ SIGNED by:_______________
Print name:_________________ Print name:_________________ DAAB Member
Title: _____________________ Title:______________________ Title:______________________
for and on behalf of the
Employer for and on behalf of the
Contractor
in the presence of in the presence of in the presence of
Witness:___________________ Witness:___________________ Witness:___________________
Name:_____________________ Name:_____________________ Name:_____________________
Address:___________________ Address:___________________ Address:___________________
__________________________ __________________________ __________________________
Date:______________________ Date:______________________ Date:______________________
Guarantee No._________________________________________ Date _________________
WHEREAS _____________________________________ (hereinafter called the 'Employer')
has entered into a Contract for __________________________________________________
(Particulars of Contract)
with ____________________________________________ (hereinafter called the "Contractor').
AND WHEREAS, the Employer has agreed to advance to the Contractor, at the Contractor's request, an amount of Pak Rupees ___________________________________ (PKR _________ ) which amount shall be advanced to the Contractor as per provisions of the Contract.
AND WHEREAS, the Employer has asked the Contractor to furnish Guarantee to secure the mobilization advance for the performance of his obligations under the said Contract.
AND WHEREAS, ____________________________________________________________
(hereinafter called the “Guarantor”) at the request of the Contractor and in consideration of theEmployer agreeing to make the above advance to the Contractor, has agreed to furnish the said Guarantee.
NOW, THEREFORE, the Guarantor hereby guarantees that the Contractor shall use the advance for the purpose of above mentioned Contract and if he fails and commits default in fulfilment of any of his obligations for which the advance payment is made, the Guarantor shall be liable to the Employer for payment not exceeding the aforementioned amount.
Notice in writing of any default,on the part of the Contractor, of which the Employer at his discretion of making decision, shall be given by the Employer to the Guarantor, and on such first written demand, payment shall be made by the Guarantor of all sums then due under this Guarantee without any reference to the Contractor and without any objection.
This Guarantee shall remain in force until the advance is fully adjusted against payments from the Interim Payment Certificates of the Contractor or until _________________________whichever is earlier. (Date)
The Guarantor's liability under this Guarantee shall not in any case exceed the sum of
PKR ______________________ (PakRupees ________________________________________________).
This Guarantee shall remain valid up to the aforesaid date and shall be null and void after the aforesaid date or earlier if the advance made to the Contractor is fully adjusted against paymentsfrom Interim Payment Certificates of the Contractor provided that the Guarantor
agrees that the aforesaid period of validity shall be deemed to be extended if on the above mentioned date the advance payment is not fully adjusted.
Guarantor
(Scheduled Bank/ Insurance Company)
Signature ________________________________________________
Name ________________________________________________
Title ________________________________________________
WITNESS:
1. ________________________________________________
________________________________________________
Corporate Secretary (Seal) Corporate Guarantor (Seal)
2. ________________________________________________
________________________________________________
Name, Title & Address
________________________________ [Guarantor letterhead or SWIFT identifier code]
Beneficiary: ___________________ [Insert name and Address of Employer]
Date: ________________[Insert date of issue]
RETENTION MONEY GUARANTEE No.: [Insert guarantee reference number]
Guarantor: [Insert name and address of place of issue, unless indicated in the letterhead]
We have been informed that ________________ [insert name of Contractor, which in the case of a joint venture shall be the name of the joint venture] (hereinafter called "the Contractor") has entered into Contract No. _____________ [insert reference number of the contract] dated ____________ with the Employer, for the execution of _____________________ [insert name of contract and brief description of Works] (hereinafter called "the Contract").
Furthermore, we understand that, according to the conditions of the Contract, the Employer retains moneys up to the limit set forth in the Contract (“the Retention Money”), and that when the Taking-Over Certificate has been issued under the Contract and the first half of the Retention Money has been certified for payment, payment of [insert the second half of the Retention Money orifthe amount guaranteed under the Performance Guarantee when the Taking-Over Certificate is issued is less than half of the Retention Money, the difference between half of the Retention Money and the amount guaranteed under the Performance Security and, if required, the ES Performance Security] is to be made against a Retention Money guarantee.
At the request of the Applicant, we, as Guarantor, hereby irrevocably undertake to pay the Beneficiary any sum or sums not exceeding in total an amount of ___________ [insert amount in figures] () [amount in words] upon receipt by us of the Employer’s complying demand supported by the Beneficiary’s statement, whether in the demand itself or in a separate signed document accompanying or identifying the demand, stating that the Applicant is in breach of its obligation(s) under the Contract, without your needing to prove or show grounds for your demand or the sum specified therein.
A demand under this guarantee may be presented as from the presentation to the Guarantor of a certificate from the Employer’s bank stating that the second half of the Retention Money as referred to above has been credited to the contractor on its account number ___________ at _________________ [insert name and address of Contractor’s bank].
This guarantee shall expire no later than the …. day of ……, 2…, and any demand for payment under it must be received by us at the office indicated above on or before that date.
____________________
[signature(s)]
Note: All italicized text (including footnotes) is for use in preparing this form and shall be deleted from the final product.
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
Name of Employer: ……………… Name of Bidder/Contractor: ……………
Signature: …………………… Signature: …………………………….
[Seal] [Seal]
Guarantee No.___________________
Executed on ____________________
Expiry date _____________________
Name of Guarantor with address: _________________________________________________________________________________________________________________________________
Name of Principal (Contractor) with address:___________________________________________________________________________________________________________________________
Penal Sum of Security (express in words and figures) ____________________________________________________________________________________________________________________
Letter of Acceptance No. _____________________________________Dated __________________
KNOW ALL MEN BY THESE PRESENTS, that in pursuance of the terms of the Bidding Documents and above said Letter of Acceptance (hereinafter called the Documents) and at the request of the said Principal we, the Guarantor above named, are held and firmly bound unto the Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad (hereinafter called the Employer) in the penal sum of the amount stated above for the payment of which sum well and truly to be made to the said Employer, we bind ourselves, our heirs, executors, administrators and successors, jointly and severally, firmly by these presents.
THE CONDITION OF THIS OBLIGATION IS SUCH, that whereas the Principal has accepted the Employer's above said Letter of Acceptance for _____________________________________ ________________________________
(Name of Contract) for the WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD. (P63434)
______________________________________________ (Name of Project).
NOW THEREFORE, if the Principal (Contractor) shall well and truly perform and fulfill all the undertakings, covenants, terms and conditions of the said Documents during the original terms of the said Documents and any extensions thereof that may be granted by the Employer, with or without notice to the Guarantor, which notice is, hereby, waived and shall also well and truly perform and fulfill all the undertakings, covenants terms and conditions of the Contract and of any and all modifications of said Documents that may hereafter be made, notice of which modifications to the Guarantor being hereby waived, then, this obligation to be void; otherwise to remain in full force and virtue till all requirements of Clause11, Defects After Taking Over, of Conditions of Contract are fulfilled.
Our total liability under this Guarantee is limited to the sum stated above and it is a condition of any liability attaching to us under this Guarantee that the claim for payment in writing shall be received by us within the validity period of this Guarantee, failing which we shall be discharged of our liability, if any, under this Guarantee.
We, _________________________________________________ (the Guarantor), waiving all objections and defense under the Contract, do hereby irrevocably and independently guarantee to pay to the Employer without delay upon the Employer's first written demand without cavil or arguments and without requiring the Employer to prove or to show grounds or reasons for such demand any sum or sums up to the amount stated above, against the Employer's written declaration that the Principal has refused or failed to perform the obligations under the Contract which payment will be effected by the Guarantor to Employer’s designated Bank & Account Number.
PROVIDED ALSO THAT the Employer shall decide, whether the Principal (Contractor) has duly performed his obligations under the Contract or has defaulted in fulfilling said obligations and the Guarantor shall pay without objection any sum or sums up to the amount stated above upon first written demand from the Employer forthwith and without any reference to the Principal or any other person.
IN WITNESS WHEREOF, the above-bounden Guarantor has executed this Instrument under its seal on the date indicated above, the name and corporate seal of the Guarantor being hereto affixed and these presents duly signed by its undersigned representative, pursuant to authority of its governing body.
Guarantor
(Schedule Bank/ Insurance Company)
Signature: _________________________________________________
Name: _________________________________________________
Title: _________________________________________________
Corporate Guarantor (Seal)
WITNESS:
1.
_________________________________________________
_________________________________________________
2.
_________________________________________________
_________________________________________________
Name, Title & Address
The bidder is required to submit Abstract of Cost.