Standard Bidding Document

📑 Procurement Notice (NIT)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

REQUEST FOR BIDS

PROCUREMENT OF CIVIL WORKS

  1. The Capital Development Authority (Works Directorate) has reserved Funds for the procurement planned for FY 2026-27. The Capital Development Authority (Works Directorate) intends to apply part of the proceeds of this Fund to cover eligible payments under the contract for the "WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD." with the reference of "P63434".
  2. The Capital Development Authority (Works Directorate) invites electronic Bids from eligible Bidders for procurement of Works (WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.) described in the bidding documents on EPADS v2.0.
  3. Single Stage-Two Envelope will be used by adopting Least Cost Based Selection (LCBS) Technique for the subject procurement, in line with the Public Procurement Rules, 2004 and any Regulations, Regulatory Guides, Procurement Guidelines or Instructions issued by the Authority from time to time.
  4. All Bids must be accompanied by a Bid Security amounting described in Bid Security Section in Bidding Document in the form of  Pay Order, Call at Deposit. Or all bids must be accompanied by bid securing declaration in the format specified in the Bidding documents
  5. E-Bidding documents, containing detailed terms & conditions, specifications and requirements etc. are available on e-Pak Acquisition and Disposal System (EPADS) at https://epads.gov.pk/opportunities/federal/procurements/63434 for all the interested bidders registered on EPADS v2.0. Bidders are required to get themselves registered on EPADS v2.0 to participate in Bidding process.
  6. The e-bids, prepared in accordance with the instructions in the e-Bidding documents, must be submitted through EPADS v2.0 on or before Friday, July 31, 2026 11:30 AM. E-bids will be opened by using EPADS v2.0 on the same day at Friday, July 31, 2026 12:00 PM. Manual submission of Bids shall not be entertained. Those vendor who have not yet registered on the new version of EPADS v2.0, may register themselves on https://pa.epads.gov.pk/. A tutorial to explain the registeration process is available at https://www.youtube.com/watch?v=MNW6T38v7tc.

In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).

 

 

Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA
Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
+92-334-856-6622
ammarpavero@gmail.com

📑 Instructions to Bidders (ITB)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

A. INTRODUCTION

  1. Scope of Bid
    1. The Procuring agency/Employer (PA), as indicated in the Bid Data Sheet (BDS) invites Bids for the execution of Works as specified in the BDS and Section V- Works Requirements. The name, identification, and number of lots (contracts) of this National/ International Competitive Bidding process are specified in the BDS.
  2. Source of Funds
    1. Source of funds as referred in Clause 2 of Bid Data Sheet.
  3. Eligible Bidders 
    1. A bidder may be natural person, company or firm or public or semi-public agency of Pakistan or any foreign country, or any combination of them with a formal existing agreement (on Judicial Papers) in the form of a joint venture or consortium. In the case of a joint venture or consortium, all members shall be jointly and severally liable for the execution of the Contract in accordance with the terms and conditions of the Contract. The joint venture or consortium shall nominate a Lead Member as nominated in the BDS, who shall have the authority to conduct all business for and on behalf of any and all the members of the joint venture or consortium during the Bidding process, and in case of award of contract, during the execution of contract. Verifiable copy of the agreement that forms a joint venture, consortium or association shall be required to be submitted as part of the Bid.
      Any bid submitted by the joint venture, consortium or association shall indicate the part of proposed contract to be performed by each party and each party shall be evaluated (or post qualified if required) with respect to its contribution only, and the responsibilities of each party shall not be substantially altered without prior written approval of the Procuring Agency and in line with any instructions issued by the Authority.
      (The limit on the number of members of JV or Consortium may be prescribed in BDS, in accordance with the guidelines issued by the PPRA).
    2. The invitation for bids is open to all prospective bidders subject to any provisions of incorporation or licensing by the respective national/ international incorporating agency or statutory body established for that particular trade or business. Procuring agencies shall specify the registration/licensing requirements for the foreign bidder keeping in view the requirement of that business.
    3. A Bidder shall not have a conflict of interest. All Bidders found to have a conflict of interest shall be disqualified. A Bidders may be considered to have a conflict of interest with one or more parties in this Bidding process, if they:
      1. are associated or have been associated in the past, directly or indirectly with a firm or any of its affiliates which have been engaged by the Procuring agency/Employer to provide consulting services for the preparation of design or technical specifications of the works that are the subject of the bid; or
      2. have controlling shareholders in common; or 
      3. receive or have received any direct or indirect subsidy from any of them; or 
      4. have the same legal representative for purposes of this Bid; or
      5. have a relationship with each other, directly or through common third parties, that puts them in a position to have access to information about or influence on the bid of another bidder, or influence the decisions of the Procuring agency/Employer regarding this Bidding process; or
      6. Submit more than one bid in this bidding process.
    4. A Bidder may be ineligible if –
      1. he is declared bankrupt or, in the case of company or firm, insolvent;
      2. payments in favor of the bidder is suspended in accordance with the judgment of a court of law other than a judgment declaring bankruptcy and resulting (in accordance with the national laws) in the total or partial loss of the right to administer and dispose of its property;
      3. the bidder is convicted, by a final judgment of a Court of Law or relevant Professional Statuary Body, of any offence involving professional conduct;
      4. The bidder is debarred/ blacklisted by a national level Procuring agency/Employer and hence debarred due to involvement in corrupt and fraudulent practices, or performance failure or due to breach of bid securing declaration.
    5. As and when required, bidders shall provide to the Procuring agency/Employer evidence of their eligibility, proof of compliance with the necessary legal requirements to carry out the contract effectively.
    6. Bidders shall submit proposal relating to the nature, conditions and modalities of sub-contracting wherever the sub-contracting of any elements of the contract is envisaged.
  4. Eligible Material and Equipment
    1. All the material and equipment to be mobilized under the contract shall have their origin in eligible source countries, and all expenditures made under the contract will be limited to such materials and equipment. For this purpose, ineligible countries are stated in the section-IV titled as “Eligible Countries”. 

B. BIDDING DOCUMENTS

  1. Contents of Bidding Documents 
    1. The scope of Works, bidding procedures, and terms and conditions of the contract are prescribed in the bidding documents.  In addition to the Invitation for Bids, the bidding documents which should be read in conjunction with any addenda issued in accordance with ITB 7.1 include:
      1. Section I -Invitation for Bids 
      2. Section II Instructions to Bidders (ITBs)
      3. Section III Bid Data Sheet (BDS)
      4. Section IV Eligible Countries
      5. Section V Evaluation and Qualification Criteria
      6. Section VI Works Requirements Technical Specifications & Schedule of Requirements
      7. Section VII Standard Bidding Forms
      8. Section VIII General Conditions of Contract (GCC)
      9. Section IX Particular Conditions of Contract (PCC)
      10. Section X Contract Forms
    2. The bidder is expected to examine all instructions, forms, specifications, terms and conditions prescribed in the bidding documents. Failure to furnish all the information required in the bidding documents will be at the bidder’s risk and may result in the rejection of his bid. 
  2. Clarification of Bidding Document, Pre-bid Meeting
    1. A prospective bidder requiring any clarification of the bidding document may notify the Procuring agency/Employer through EPADS v2.0
    2. The Procuring agency/Employer shall respond to the request for clarification in accordance with the Public Procurement Rules 2004, Rule No.31 i.e. Clarification of bids
    3. Should the Procuring Agency deem it necessary to amend the BIDDING document as a result of a clarification, it shall do so following the procedure under ITB 7.
    4. If indicated in the BDS, the bidder’s designated representative is invited at the bidder’s cost to attend a pre-bid meeting at the place, date and time mentioned in the BDS. During this pre-bid meeting, prospective bidders may request clarification of the schedule of requirement, the evaluation criteria or any other aspects of the bidding documents.
    5. Minutes of the pre-bid meeting, if applicable, including the text of the questions asked by bidders, including those during the meeting (without identifying the source) and the responses given, together with any responses prepared after the meeting will be uploaded on EPADS v2.0. Any modification to the bidding documents that may become necessary as a result of the pre-bid meeting shall be made by the Procuring agency/Employer exclusively through the use of an Addendum pursuant to ITB 7. Non-attendance at the pre-bid meeting will not be a cause for disqualification of a bidder.
    6. The bidder is advised to visit and examine the Site of Works and its surroundings and obtain for itself on its own responsibility all information that may be necessary for preparing the bid and entering into a contract for construction of the Works.  The costs of visiting the Site shall be at the bidder’s own expense.
    7. The bidder and any of its authorized personnel will be granted permission by the Procuring agency/Employer to enter upon its premises and lands for the purpose of such visit, but only upon the express condition that the bidder and its personnel will release and indemnify the Procuring agency/Employer  from and against all liability in respect thereof, and will be responsible for death or personal injury, loss of or damage to property, and any other loss, damage, costs, and expenses incurred as a result of the inspection.
  3. Amendment of Bidding Documents
    1. The procuring agency may issue notification of any change, addition, modification or deletion in accordance with the PP Rules 2004, rule no. 23 i.e. Bidding Documents.
    2. To give prospective bidders reasonable time in which to take an addendum/corrigendum into account in preparing their bids, the Procuring agency/Employer may, at its discretion, extend the deadline for the submission of bids:
      Provided that the Procuring agency/Employer shall extend the deadline for submission of bid in pursuance of PP Rules 2004, rule no. 27 i.e. Extension of time for submission of bids, if such an addendum is issued within last three (03) days of the bid submission deadline.

C. PREPARATION OF BIDS

  1. Language of Bid
    1. The bid prepared by the bidder, as well as all correspondence and documents relating to the bid exchanged by the bidder and the Procuring agency/Employer shall be written in the English language unless specified in the BDS. Supporting documents and printed literature furnished by the bidder may be in another language provided they are accompanied by an accurate translation of the relevant pages in the English language unless specified in the BDS, in which case, for purposes of interpretation of the bidder, the translation shall govern.
  2. Documents Constituting the Bids
    1. The Bids prepared by the Bidder shall constitute of all the documents required in the BDS
  3. Documents Establishing Eligibility of Material, Equipment and Works, their Conformity to Bidding Documents
    1. The bid prepared by the bidder shall constitute the following components: -
      1. Documentary evidence established in accordance with ITB 10 that the material and equipment to be utilized by the Bidder for the executions of works are eligible material and equipment and conform to the Bidding Documents;
      2. Documentary evidence established in accordance with ITB 11 that the bidder has been authorized to carry out the Construction works;
      3. Documentary evidence established in accordance with ITB 11 that the bidder is eligible and/or qualified for the subject bidding process;
      4. Form of Bid and Bid Prices completed in accordance with ITB 12 and 13
      5. Completed schedules as required, including priced Bill of Quantities in accordance with ITB 13.
      6. Technical Proposal completed in all aspects in accordance with ITB-15
      7. Bid security or Bid Securing Declaration furnished in accordance with ITB 17;
      8. Any other document required in the BDS.
    2. In addition to the requirements, bids submitted by a JV shall include a copy of the Joint Venture Agreement entered into by all members. Alternatively, a letter of intent to execute a Joint Venture Agreement in the event of a successful bid shall be signed by all members and submitted with the bid, together with a copy of the proposed Agreement.
    3. The bidder shall furnish, as part of its bid, all those documents establishing the eligibility in conformity to the terms and conditions specified in the bidding documents for all material, equipment and works which the bidder proposes to execute.
    4. The documentary evidence of conformity of the material, equipment and works to the Bidding Documents may be in the form of literature, drawings, and data, and shall consist of:
      1. a detailed description of the work methodology, approach, schedule and resources to be mobilized at site;
      2. an item-by-item commentary on the Procuring agency/Employer’s Technical Specifications demonstrating substantial responsiveness of the material, equipment and works to those specifications, or a statement of deviations and exceptions to the provisions of the Technical Specifications;
      3. any other procurement specific documentation requirement as stated in the BDS.
    5. The required documents and other accompanying documents must be in English. In case any other language than English is used the pertinent translation into English shall be attached to the original version.
  4. Documents Establishing Eligibility and Qualification of the Bidder
    1. The bidder shall furnish, as part of its bid, all those documents establishing the bidder’s eligibility to participate in the bidding process and/or its qualification to perform the contract if its bid is accepted.
    2. The documentary evidence of the bidder’s eligibility to bid shall establish to the satisfaction of the Procuring agency/Employer that the bidder, at the time of submission of its bid, is from an eligible country as defined in Section-IV titled as “Eligible Countries”.
    3. The documentary evidence of the bidder’s qualification to perform the contract if its bid is accepted shall establish to the satisfaction of Procuring agency/Employer that:
      1. The bidder has the financial and technical capability necessary to perform the Contract, meets the qualification criteria specified in Section-V, Evaluation and Qualification Criteria and BDS.
      2. In the case of a bidder not doing business within Pakistan, the bidder is or will be (if awarded the contract) represented by a local bidder (Joint Venture) in accordance with the PEC works bylaws, and in case of award of works such foreign firm is required to participate in the execution of works to carry out its obligations as prescribed in the Conditions of Contract and /or Technical Specifications.
      3. That the bidder meets the qualification criteria listed in Section-V, Evaluation and Qualification Criteria and BDS
  5. Forms of Bid
    1. The Bidder shall fill the Form of Bids furnished in the bidding documents. The Bids Form must be completed without any alterations to its format and no substitute shall be accepted.
  6. Bid Prices
    1. The bid prices quoted by the bidder in the Standard bid Forms, Bill of Quantities and in the Price Schedules shall conform to the requirements specified below or exclusively mentioned hereafter in the bidding documents.
    2. The bidder shall fill in rates and prices for all items of the Works described in the Bill of Quantities. If a Price Schedule shows items listed but not priced, their prices shall be construed to be included in the prices of other items in the Bill of Quantities and will not be paid for separately by the Procuring agency/Employer. 
    3. Items not listed in the Price Schedule shall be assumed not to be included in the bid, and provided that the bid is still substantially responsive in their absence or due to their nominal nature, the corresponding average price of the respective item(s) of the remaining substantially responsive bidder(s) shall be construed to be the price of those missing item(s):
      Provided that:
      1. where there is only one (substantially) responsive bidder, or
      2. where there is provision for alternate proposals and the respective items are not listed in the other bids,
        The Procuring agency/Employer may fix the price of missing items in accordance with market survey, and the same shall be considered as final price. 
    4. The Bid price to be quoted in the Form of Bid in accordance with ITB 12 shall be the total price of the bid.
    5. Unless otherwise specified in the BDS and the Contract, the rates and prices quoted by the bidder are subject to adjustment during the performance of the Contract in accordance with the provisions of the Conditions of Contract.
    6. If so specified in ITB 1.1, bids may be invited for individual lots (contracts) or for any combination of lots (packages).
    7. Prices quoted by the Bidder shall be fixed during the bidder’s performance of the contract and not subject to variation on any account. A bid submitted with an adjustable price will be treated as non-responsive and shall be rejected, pursuant to ITB 27, unless otherwise price adjustment is permissible under Conditions of the Contract.
    8. All duties, taxes, and other levies payable by the Contractor under the Contract, or for any other cause, as of the date twenty-eight (28) days prior to the deadline for submission of bids, shall be included in the rates and prices and the total bid price submitted by the bidder.
  7. Currencies of Bid and Payment
    1. Prices shall be quoted in Pakistani Rupees unless otherwise specified in the BDS. Comparison of bids and tie of bid shall be treated in accordance with the PP rules 2004, rule no. 30.
  8. Documents Comprising the Technical Proposal
    1. The bidder shall furnish a Technical Proposal including a statement of work methods, equipment, personnel, schedule and any other information as stipulated in Section VII – Standard Bid Forms, in sufficient detail to demonstrate the adequacy of the bidder’s proposal to meet the work requirements and the completion time.
  9. Bid Validity Period
    1. Bids shall remain valid for the period specified in the BDS after the bid submission deadline prescribed by the Procuring agency/Employer. A bid valid for a shorter period shall be rejected by the Procuring agency/Employer as non-responsive. The period of bid validity will be determined from the complementary bid securing instrument i.e. the expiry period of bid security or bid securing declaration as the case may be. 
    2. Under exceptional circumstances, prior to the expiration of the initial Bids/Bid validity period, the Procuring Agency may request the Bidders’ consent to an extension of the period of validity of their Bids/Bid. Such request for extension of the period of bid validity shall be carried out in accordance with the PP rules 2004, rule no. 26 i.e. Bid Validity.
  10. Bid Security or Bid Securing Declaration
    1. Pursuant to ITB 11.1 unless otherwise specified in the BDS, the bidder shall furnish as part of its bid, a Bid Security in accordance with the PP Rules 2004, rule no. 25   in the amount and currency specified in the BDS or Bid Securing Declaration as specified in the BDS in the format provided in Section VII (Standard Bidding Forms). 
      In case Procuring agency/Employer is inviting bids in lots / packages, the bidder shall be required to submit his bid security against the respective lot/ package for which he is submitting his bid.
      Until the development of functionality of auto verification of financial instrument in EPADS v2.0, the scanned copy of bid security or bid securing declaration, as the case may be, shall be uploaded on EPADS v2.0 whereas the original instrument to be submitted to the procuring agency before closing of bid submission deadline,
    2. The Bid Security shall be denominated in the local currency or in another freely convertible currency, and it shall be in the form specified in the BDS which shall be in any of the following:
      1. A bank guarantee, an irrevocable letter of credit issued by a Scheduled bank in the form provided in the Bidding Documents or another form acceptable to the Procuring agency/Employer and valid for twenty-eight (28) days beyond the end of the validity of the Bid. This shall also apply if the period for Bid Validity is extended. In either case, the form must include the complete name of the bidder; 
      2. A cashier’s or certified cheque; or
      3. Another security as indicated in the BDS.
    3. The Bid Security or Bid Securing Declaration shall be in accordance with the Form of the Bid Security or Bid Securing Declaration included in Section VII (Standard Bidding Forms) or another form approved by the Procuring agency/Employer prior to the bid submission.
    4. The Bid Security shall be payable promptly upon written demand by the Procuring agency/Employer in case any of the conditions listed in ITB 17.9 are invoked.
    5. Any bid not accompanied by a Bid Security or Bid Securing Declaration in accordance with ITB 17.1 or 17.3 shall be rejected by the Procuring agency/Employer and shall be declared as non-responsive bid, pursuant to ITB 27.
    6. Unsuccessful bidders’ Bid Security will be discharged or returned as promptly as possible, however in no case later than thirty (30) days after the expiration of the period of Bid Validity prescribed by the Procuring agency/Employer pursuant to ITB 16. The Procuring agency/Employer shall make no claim to the amount of the Bid Security, and shall promptly return the Bid Security document, after whichever of the following that occurs earliest:
      1. The expiry of the Bid Security;
      2. The entry into force of a procurement contract and the provision of a performance security (or guarantee), for the performance of the contract if such a security (or guarantee), is required by the Biding documents;
      3. The rejection by the Procuring agency/Employer of all Bids;
      4. The withdrawal of the bid prior to the deadline for the submission of bids, unless the biding documents stipulate that no such withdrawal is permitted.
    7. The successful bidder’s Bid Security will be discharged upon the bidder signing the contract pursuant to ITB 40, or furnishing the performance security (or guarantee), pursuant to ITB 41.
    8. The Bid Security may be forfeited or the Bid Securing Declaration executed:
      if a Bidder:
      1. Withdraws its Bid during the period of Bid Validity as specified by the Procuring agency/Employer, and referred by the bidder on the Form of Bid except as provided for in ITB 16.2; or 
      2. In the case of a successful bidder, if the bidder fails:
        1. to sign the contract in accordance with ITB 40; or
        2. to furnish performance security (or guarantee) in accordance with ITB 41.
    9. In case of Bid Security issued by the foreign bank is allowed by the Procuring agency/Employer, the same should be counter guaranteed by a corresponding bank in Pakistan. Furthermore, in case of joint venture, it should be in the name of Joint venture to ensure joint responsibility. In case the JV is not legally constituted at the time of bid submission, the bid security or bid securing declaration shall be in the names of all future members as named in the letter of bid.
  11. Withdrawal of Bids
    1. Before bid submission deadline, any bidder may withdraw, substitute, or modify its bid after it has been submitted by sending a written notice, duly signed by an authorized representative, and the corresponding must accompany the respective written notice. 
  12. Format and Signing of Bid
    1. The Bidder shall prepare and submit Bids through EPADS with due diligence after carefully reading all the terms and condition before bid submission deadline.

D. SUBMISSION OF BIDS

  1. Submission of Bids
    1. All bids shall be submitted through EPADS v2.0.
  2. Deadline for Submission of Bids
    1. All bids shall be received through EPADS v2.0 not later than bid submission deadline as specified in the BDS.
    2. The Procuring agency/Employer may, under exceptional circumstances and at its discretion, extend the deadline for the submission of bids, pursuant to PP Rules 2025, rule no.39 Extension of Time for submission of bid, by amending the Bidding Documents in accordance with ITB 7, in which case all rights and obligations of the Procuring agency/Employer and bidders previously subject to the deadline will thereafter be subject to the new deadline.
  3. Substitution and Modification of bids
    1. A bidder may substitute or modify his bid after it has been submitted, provided that written notice of the substitution or modification of the bid, is received by the Procuring agency/Employer prior to the deadline for submission of bids.
    2. Revised bid may be submitted after the substitution or modification made in the original bid in accordance with the provisions referred in ITB 18. 

E. OPENING AND EVALUATION OF BIDS

  1. Opening of Bids
    1. The Procuring Agency will open bids in accordance with the PP rules 2004, rule no 28 and as specified in the BDS.
  2. Confidentiality
    1. Information relating to the examination, clarification, evaluation and comparison of bids and recommendation of contract award shall not be disclosed to bidders or any other persons not officially concerned with such process until the time of the announcement of the respective evaluation report.
  3. Clarification of Bids
    1. Clarification of Bidding Documents shall be carried out in accordance with the PP Rules 2025, rule no 38 i.e. Clarifications.
    2. The alteration or modification in the bid which in any case affect the following parameters will be considered as a change in the substance of a bid:
      1. evaluation & qualification criteria;
      2. required scope of work;
      3. contract price;
      4. all securities requirements;
      5. tax requirements;
      6. terms and conditions of bidding documents.
      7. change in the ranking of the bidder
  4. Preliminary Examination of Bids
    1. Prior to the detailed evaluation of bids, the Procuring agency/Employer will determine whether each bid:
      1. meets the eligibility criteria defined in ITB 3 and ITB 4;
      2. has been prepared as per the format and contents defined by the Procuring agency/Employer in the bidding documents;
      3. has been properly signed; 
      4. is accompanied by the required securities; and 
      5. is substantially responsive to the requirements of the bidding documents. 
        The Procuring agency/Employer's determination of a bid's substantial responsiveness will be based on the contents of the bid itself.
    2. A substantially responsive Bid is one which conforms to all the terms, conditions, and specifications of the Bidding Documents, without material deviation or reservation. A material deviation or reservation is one that: - 
      1. affects in any substantial way the scope, quality, or performance of the Works; 
      2. limits in any substantial way, inconsistent with the bidding documents, the Procuring agency/Employer's rights or the bidders’ obligations under the Contract; or 
      3. if rectified, would affect unfairly the competitive position of other bidders presenting substantially responsive bids.
    3. The Procuring agency/Employer will confirm that the documents and information specified under ITB 9, 10 and 11 have been provided in the bid. If any of these documents or information is missing, or is not provided in accordance with the Instructions to Bidders, the bid shall be rejected.
    4. The Procuring agency/Employer may waive-off any minor informality, nonconformity, or irregularity in a bid which does not constitute a material deviation, provided such waiver does not prejudice or affect the relative ranking of any Bidder.
      Explanation: A minor informality, non-conformity or irregularity is one that is merely a matter of form and not of substance. It also pertains to some immaterial defect in a Bid or variation of a bid from the exact requirements of the invitation that can be corrected or waived without being prejudicial to other bidders. The defect or variation is immaterial when the effect on quantity, quality, or delivery is negligible when contrasted with the total cost or scope of the works. The Procuring agency/Employer either shall give the bidder an opportunity to cure any deficiency resulting from a minor informality or irregularity in a bid or waive the deficiency, whichever is advantageous to the Procuring agency/Employer. Examples of minor informalities or irregularities include failure of a bidder to –
      1. Submit the number of copies of signed bids required by the invitation;
      2. Furnish required information concerning the number of its employees;
      3. the firm submitting a bid has formally adopted or authorized, before the date set for opening of bids, the execution of documents by typewritten, printed, or stamped signature and submits evidence of such authorization and the bid carries such a signature.
    5. Provided that a Technical Bid is substantially responsive, the Procuring agency/Employer may request the bidder to submit the necessary information or documentation, within a reasonable period of time, to rectify nonmaterial nonconformities or omissions in the Technical Bid related to documentation requirements. Requesting information or documentation on such nonconformities shall not be related to any such aspect of the technical Proposal linked with the ranking of the bidders. Failure of the bidder to comply with the request may result in the rejection of its bid.
    6. Provided that a Technical Bid is substantially responsive, the Procuring agency/Employer shall rectify quantifiable nonmaterial nonconformities or omissions related to the Financial Proposal. To this effect, the Bid Price shall be adjusted, for comparison purposes only, to reflect the price of the missing or nonconforming item or component.
    7. If a bid is not substantially responsive, it will be rejected by the Procuring agency/Employer and may not subsequently be evaluated for complete technical responsiveness.
  5. Examination of Terms and Conditions; Technical Evaluation
    1. The Procuring agency/Employer shall examine the bid to confirm that all terms and conditions specified in the GCC and the PCC have been accepted by the bidder without any material deviation or reservation.
      For this purpose:
      Deviation” means departure from the requirements specified in the Bidding Document.
      Reservation” means setting of limiting conditions or withholding from complete acceptance of the requirements specified in the Bidding Document.
    2. The Procuring agency/Employer shall evaluate the technical aspects of the bid submitted in accordance with ITB 30, to confirm that all requirements specified in Section VI – Works Requirement, Technical Specifications of the Bidding Documents have been met without material deviation or reservation.
    3. If after the examination of the terms and conditions and the technical evaluation, the Procuring agency/Employer determines that the bid is not substantially responsive in accordance with ITB 27, it shall reject the bid.
  6. Correction of Arithmetic Errors
    1. Bids determined to be substantially responsive will be checked for any arithmetic errors.  Errors will be corrected as follows: -
      1. if there is a discrepancy between unit prices and the sub-total price that is obtained by multiplying the unit price and quantity, the unit price shall prevail, and the sub-total price shall be corrected, unless in the opinion of the Procuring agency/Employer there is an obvious misplacement of the decimal point in the unit price, in which the total price as quoted shall govern and the unit price shall be corrected;
      2. if there is an error in a total corresponding to the addition or subtraction of sub-totals, the sub-totals shall prevail, and the total shall be corrected; and 
      3. where there is a discrepancy between the amounts in figures and in words, the amount in words will govern.
      4. Where there is discrepancy between grand total of price schedule and amount mentioned on the Form of Bid, the amount referred in Price Schedule shall be treated as correct subject to elimination of other errors. 
    2. The amount stated in the Bid will, be rectified by the Procuring agency/Employer in accordance with the above procedure for the correction of errors and, with, the concurrence of the bidder, shall be considered as binding upon the bidder. If the bidder does not accept the corrected amount, its bid shall be rejected after forfeiture of Bid Security or execution of the Bid Securing Declaration, as the case may be, in accordance with ITB 41.3.
  7. Conversion to Single Currency
    1. The unit rates and the prices shall be quoted by the bidder entirely in Pak rupees. A bidder expecting to incur expenditures in other currencies for inputs to the Works from outside the Procuring agency/Employer’s country (referred to as the “Foreign Currency Requirements”) shall indicate the same in the letter of bid-financial proposal. The proportion of the Bid Price (excluding Provisional Sums) needed by him for the payment of such Foreign Currency Requirements either (i) entirely in the currency of the Bidder’s home country or, (ii) at the bidder’s option, entirely in Pak rupees provided always that a bidder expecting to incur expenditures in a currency or currencies other than those stated in (i) and (ii) above for a portion of the foreign currency requirements, and wishing to be paid accordingly, shall indicate the respective portions in his bid. Comparison of bids quoted in different currencies and conversion of bids into a single currency shall be carried out in accordance with the PP Rule 2004, rule no. 30 (2).
  8. Evaluation of Bids
    1. The Procuring agency/Employer shall evaluate and compare only the bids determined to be substantially responsive, pursuant to ITB 27.
    2. In evaluating the Technical Proposal of each Bid, the Procuring agency/Employer shall use the criteria and methodologies listed in the BDS and in terms of works requirement. No other evaluation criteria or methodologies shall be permitted.
    3. The Procuring agency/Employer’s evaluation of a bid will take into account:
      1. the bid price, excluding provisional sums and the provision, if any, for contingencies in the summary bill of quantities, but including day work items, where priced competitively;
      2. converting the amount resulting from applying above, if relevant, to a single currency in accordance with ITB 29;
    4. The estimated effect of the price adjustment provisions of the Conditions of Contract, applied over the period of execution of the Contract, shall not be taken into account in bid evaluation.
    5. If these bidding documents allow bidders to quote separate prices for different lots, and the award to a single bidder of multiple lots, the methodology of evaluation to determine the lowest evaluated lot combinations in the Form of Bid, is specified in the BDS.
    6. If the bid, which results in the Evaluated Bid Price (Successful Bid), is seriously unbalanced or front loaded in the opinion of the Employer, the Employer may require the Bidder to produce detailed price analyses for any or all items of the Bill of Quantities, to demonstrate the internal consistency of those prices with the construction methods and schedule proposed. After evaluation of the price analyses, taking into consideration the schedule of estimated Contract payments, the Employer may require that the amount of the performance security be increased at the expense of the Bidder to a level sufficient to protect the Employer against financial loss in the event of default of the successful Bidder under the Contract.
      Explanation:
      “Unbalanced” or “front-loaded” bids consist of deliberately submitting bids with artificially high prices or unit rates for the early stages of a construction project, offset by artificially low prices or unit rates for the later stages of the project, to improve the contractor’s cash flow.
  9. Domestic Preference
    1. If the BDS so specifies, the Procuring agency/Employer will grant a margin of preference to the domestic contractor in line with the rules, regulations, regulatory guides or instructions issued by the Authority from time to time. 
  10. Determination of Successful Bid
    1. The Procuring agency/Employer shall compare the evaluated bids in accordance with the predefined bidding procedure, of all substantially responsive bids to determine the Successful bidder.
  11. Qualification of Bidder
    1. The Procuring agency/Employer shall determine to its satisfaction whether the bidder is substantially responsive and whose bid is declared as Successful bid either continues to meet (if prequalification applies) or meets (if post-qualification applies) the qualifying criteria specified in Evaluation and Qualification Criteria.
      Note: In case of international bidding, the parameters for incorporation or licensing within Pakistan may be fulfilled as part of post qualification.
    2. The determination shall be based upon an examination of the documentary evidence of the bidder’s qualifications submitted by the bidder, pursuant to ITB 11.
    3. Prior to contract award, the Procuring agency/Employer will verify that the successful bidder (including each member of a JV) is not blacklisted/debarred. The Procuring agency/Employer will conduct the same verification for each sub-contractor proposed by the successful bidder.
  12. Sub-Contractors
    1. The bidder shall provide details regarding any specialized sub-contractor to the Procuring agency/Employer. In case change of sub-contractors, the bidder shall promptly notify the Procuring agency/Employer and obtain approval for replacement of sub-contractors.
    2. Bidders may propose sub-contracting up to the percentage of total value of contracts or the volume of works as specified in the BDS.
  13. Abnormally Low Financial Bid
    1. A procuring Agency may reject abnormally low bids in accordance with the PP Rules 2025 rule no. 43. The decision of the Procuring agency/Employer to reject a bid and reasons for the decision shall be recorded in the procurement proceedings and promptly communicated to the bidder concerned. Moreover, the Procuring agency/Employer shall not incur any liability solely by rejecting abnormally bid 
      Guidance for Procuring agency/Employer:
      An abnormally low bid means, in the light of the Procuring agency/Employer’s estimate and of all the bids submitted, the bid appears to be abnormally low by not providing a margin for normal levels of profit. In order to identify the Abnormally Low Bid (ALB) following approaches can be considered to minimize the scope of subjectivity:
      1. Comparing the bid price with the cost estimate;
      2. Comparing the bid price with the bids offered by other bidders submitting substantially responsive bids; and
      3. Comparing the bid price with prices paid in similar contracts in the recent past either government- or development partner-funded.
    2. The Procuring agency/Employer will determine to its satisfaction whether the bidder that is selected as having submitted the successful bid is qualified to perform the contract satisfactorily, in accordance with the criteria listed in ITB 11
    3. The determination will take into account the bidder’s financial and technical capabilities.  It will be based upon an examination of the documentary evidence of the bidder’s qualifications submitted by the bidder, pursuant to ITB 11, as well as such other information as the Procuring agency/Employer deems necessary and appropriate. Factors not included in these bidding documents shall not be used in the evaluation of the bidders’ qualifications.
    4. Procuring agency/Employer may seek “Certificate for Independent Price Determination” from the bidder and the results of reference checks may be used in determining award of contract.
      Explanation: The Certificate shall be furnished by the bidder. The bidder shall certify that the price is determined keeping in view of all the essential aspects such as raw material, its processing, value addition, optimization of resources due to economy of scale, transportation, insurance and margin of profit etc. 
    5. An affirmative determination will be a prerequisite for award of the contract to the bidder. A negative determination will result in rejection of the bidder’s bid, in which event the Procuring agency/Employer will proceed to the next ranked bidder to make a similar determination of that bidder’s capabilities to perform satisfactorily.

F. AWARD OF CONTRACT

  1. Criteria of Award
    1. Subject to ITB 36 and 37, the Procuring agency/Employer will award the Contract to the bidder whose bid has been determined to be substantially responsive to the bidding documents and who has been declared as Successful Bidder, provided that such bidder has been determined to be:
      1. eligible in accordance with the provisions of ITB 3;
      2. is determined to be qualified to perform the Contract satisfactorily; and 
      3. Successful negotiations have been concluded, if any.
  2. Negotiations
    1. The Committee of the Procuring agency/Employer may negotiate with the Most Advantageous Bidder relating to the following areas:
      1. a minor alteration to the technical (drawings, design technical specifications) details of the statement of works;
      2. Methodology, work plan, staffing in view to streamline the work;
      3. a minor amendment to the Particular conditions of Contract;
      4. finalizing payment arrangements;
      5. clarifying details that were not apparent or could not be finalized at the time of Bidding;
    2. Where negotiation fails to result into an agreement, the Procuring agency/Employer may invite the next ranked bidder for negotiations. Where negotiations are commenced with the next ranked bidder, the Procuring agency/Employer shall not reopen earlier negotiations.
  3. Procuring agency/Employer’s Right to reject All Bids
    1. The procuring agency has the right to reject all bids in accordance with the PP Rules 2025 rule no. 45. However, the Authority (i.e. PPRA) may call from the Procuring agency/Employer the justification of those grounds.
  4. Notification of Award
    1. The procuring agency shall announce and publish the evaluation result in accordance with the PP Rules 2004, rule no. 40.
    2. Where no complaints have been lodged, the bidder whose bid has been accepted will be notified of the award by the Procuring agency/Employer prior to expiration of the bid validity period through EPADS. However, the Procuring agency/Employer shall not award any procurement contract at least for five (05) days after the announcement of final evaluation report. The notification letter (herein after and in the condition of the contract and contract form called “Letter of Acceptance” will specify the sum that the Procuring agency/Employer will pay the successful bidder in consideration for the execution and completion of the works as prescribed by the Contract (hereinafter and in the Contract called the "Contract Price).
    3. The notification of award will constitute the formation of the Contract, subject to the bidder furnishing the Performance Security (or guarantee) in accordance with ITB 41 and signing of the contract in accordance with ITB 40. 
    4. Upon the successful bidder’s furnishing of the performance security (or guarantee) pursuant to ITB 41, the Procuring agency/Employer will promptly notify each unsuccessful bidder, the name of the successful bidder and the Contract amount and will discharge the Bid Security or Bid Securing Declaration of the bidder(s) pursuant to ITB 17. 
  5. Signing of Contract
    1. Promptly after notification of award, Procuring agency/Employer shall send the successful bidder the draft agreement, incorporating all terms and conditions as agreed by the parties to the contract.
    2. Immediately after the Redressal of grievance by the GRC, and after fulfillment of all conditions precedent of the Contract Form, the successful bidder and the Procuring agency/Employer shall sign the contract.
    3. Where no formal signing of a contract is required, work order issued to the bidder shall be construed to be the contract.
  6. Performance Security (or Guarantee)
    1. After the receipt of the Letter of Acceptance, the successful bidder, within the specified time, shall deliver to the Procuring agency/Employer a Performance Guarantee in the amount and in the form stipulated in the BDS and PCC, denominated in the type and proportions of currencies in the Letter of Acceptance and in accordance with the Conditions of Contract.
    2. If the Performance Guarantee is provided by the successful bidder and it shall be in the form specified in the BDS which shall be in any of the following:
      1. certified cheque, cashier’s or manager’s cheque, or bank draft;
      2. irrevocable letter of credit issued by a scheduled bank of Pakistan or in the case of an irrevocable letter of credit issued by a foreign bank, the letter shall be confirmed or authenticated by a scheduled bank of Pakistan;
      3. bank guarantee confirmed by a reputable local bank or, in the case of a successful foreign bidder, bonded by a foreign bank; or
      4. surety bond callable upon demand issued by any reputable surety or insurance company.
        Any Performance Guarantee submitted shall be enforceable in Pakistan.
    3. Failure of the Most Advantageous Bidder to comply with the requirement of ITB 40 shall constitute sufficient grounds for the annulment of the award and forfeiture of the Bid Security or declare blacklisted (in case bid securing declaration is submitted) in which event the Procuring agency/Employer may make the award to the next most advantageous bidder or reinitiate the procurement process afresh (as a case may be).
  7. Advance Payment
    1. Advance payment will be provided to the bidder in percentage and in the manner as agreed by the both parties in terms of Conditions of the Contract.
    2. The Procuring agency/Employer will provide an advance payment as stipulated in the Conditions of Contract, subject to a maximum amount, as stated and/or Conditions of the Contract.  The advance payment request shall be accompanied by an advance payment security (guarantee) in the form provided in Section X. For the purpose of receiving the advance payment, the bidder shall make and estimate of, and include in its bid, the expenses that will relate to the purchase of equipment, machinery, materials, and on the engagement of labor during the first month beginning with the date of the Procuring agency/Employer’s “Notice to Commence” as specified in the PCC.
  8. General Performance of the Bidders
    1. The Procuring agency/Employer reserves the right to obtain information regarding performance of the bidders on their previously awarded contracts / works. The Procuring agency/Employer may seek information / report from the previous employer for consideration. However, the Procuring agency/Employer shall incorporate such parameters in the evaluation criteria and accordingly decide the fate of the bid submitted.
  9. Corrupt & Fraudulent Practices
    1. Procuring agencies (including beneficiaries of Government funded projects and procurement) as well as Bidders/Suppliers/Contractors under Government financed contracts, observe the highest standard of ethics during the procurement and execution of such contracts, and will avoid to engage in any corrupt and fraudulent practices.

G. GRIEVANCE REDRESSAL & COMPLAINT REVIEW MECHANISM

  1. Grievance Redressal
    1. Grievance Redressal shall be carried out in accordance with the PP Rules 2025, rule no. 65 i.e. Redressal of grievances by the procuring agency and “Redressal of Grievances Regulations 2021”.

H. MECHANISM OF BLACKLISTING

  1. Mechanism of Blacklisting
    1. The Procuring agency/Employer shall proceed Blacklisting of Bidders/Contractors in accordance with PP Rules 2025, rule no.25 i.e. Blacklisting and “Blacklisting and Debarment of Bidders or Contractors Regulations 2024. 

📑 Bid Data Sheet (BDS)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

Bid Data Sheet (BDS)

The following specific data for the procurement of works shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITBs).  Whenever there is a conflict, the provisions herein shall prevail over those in ITBs.

A. Introduction

ITB Number   
Amendments of, and Supplements to, Clauses in the Instruction to Bidders

ITB Number 1.1

Name of Procuring agency/Employer: Capital Development Authority (Works Directorate)

The subject of procurement is: WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Period for completion of the works 4 Months

Commencement date execution of the works: 14 Days

Type of Procurement: Local

ITB Number 2.1

Financial year for the operations of the Procuring agency/Employer: 2026-27Name of Project [insert: name and summary description of the Project if any] 

Name of financing institution: [insert: name if any]

Name and identification number of the Contract: P63434 

ITB Number 3.1

JV/Consortium or Association Allowed: Yes

Maximum number of members in the joint venture shall be: 3.

B. Bidding Documents

ITB Number 6.4

The Bidders may seek clarifications through EPADS v2.0: Last Clarification Date: Thursday, July 23, 2026

C. Preparation of Bids

ITB Number 8.1

The Language of all correspondences and documents related to the Bid is: English

ITB Number 5.1 & 9.1 

The following documents must be included to constitute the Bid

 

  1. Filled in, Signed and Stamp letter of Technical Bid.
  2. Signed and Stamp Integrity Pact

ITB Number 9.4 (b)

Other procurement specific documentation requirements are: 

The bidder shall submit with its pricedbid the following documents to be uploded on E-PADS

  • Duly filled in signed and stamped Letter of Price Bid.
  • Bill of Quantities.
  • Estimated Progress Payments.
 

ITB Number 12.4

The Bid price will be/will not be subject to the price adjustment Nil.

ITB Number 12.6

The Bid price shall be adjusted in accordance with Schedule-A to Bid – “Schedule of Adjustment Data” if available. 

ITB Number 13.1

Bidders to quote entirely in Pak rupees (PKR)

ITB Number 15.1

The Bid Validity period shall be 120 Days days.

ITB Number 16.1

The amount of Bid Security shall be (insert amount)  

The currency of the Bid Security shall be: PKR.

ITB Number 16.2

The Bid Security shall be in the form of: Pay Order, Call at Deposit

D. Submission of Bids

ITB Number 19.1

The deadline for Bid submission is: Friday, July 31, 2026 11:30 AM
Address for submission of Original Bid Security: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad

ITB Number  21.1
The Bid opening shall take place at: EPADS v2.0
Day : Friday
Date: July 31, 2026
Time : 12:00 PM

ITB Number 27.1
The currency that shall be used for Bid evaluation and comparison purposes to convert all Bid prices expressed in various currencies is: PKR Only
The source of exchange rate shall be: Nil
The date of exchange rate shall be: Nil

ITB Number 28.2 & 28.5
Least Cost Based Selection (LCBS)

see Evaluation Criteria

ITB Number 29.1
Domestic preference to apply.
Domestic preference: No  
Preference to domestic or national suppliers or contractors shall be provided in accordance with policies of the Federal Government and/or in accordance with the regulations issued by the Authority.
If Yes, The percentage for the domestic preference alongwith calculation formula is provided in the evaluation and qualification criteria.

ITB Number 32.2
Sub-contracting is allowed? : No

No % of the total value of the contract.

39.1    The Performance Security (or guarantee) shall be 10.00%
39.2    The Performance Security (or guarantee) shall be in the form of: Bank Guarantee

Eligibility Criteria

Bidder's TypeRequired Registration
Sole Proprietorship
Partnership Firm
Company (Private Limited)
Company (Public Limited)
Company (Limited by Guarantee)
State Owned Enterprise (Private Limited)
State Owned Enterprise (Public Limited)
NADRA CITIZENSHIP (CNIC/NICOP)
FBR (NTN)
FBR (GSTN)
PEC
Eligibility CriteriaDocument
The Contractor/Firm having valid registration for the year 2026-27 with Pakistan Engineering Council in Category C-3 or above with specialization codes CE-01, CE-09, CE-10, EE-02, EE-04, EE-06, EE-07 & ME-02 are eligible to apply.Yes
The bidder shall submit written power of Attorney authorizing the signatory of the bid to act for and on behalf of the bidder. The name and position held be each person signing the authorization must be typed or printed below the signature.Yes

Evaluation Criteria

Least Cost Based Selection (LCBS)

Technical Marks100
Passing Marks70
WORKING EXPERIENCE
Number of completed contracts of public sector Sports Facility Related works (i.e. Government or Semi Government organization or autonomous bodies or authorities) of minimum value of 60 % of the laydown cost of the project completed in the last 10 years. **NOTE** In case of Joint Venture, the working experience of leader of the Joint Venture shall be evaluated. **DOCUMENTATION REQUIREMENT** The bidder must upload Project Award Letter, Work Orders or Contract Agreement & completion Certificates and other documents necessary for confirming scope of works i.e. BOQs, IPC’s etc. The bidder must upload joint venture agreement in case of projects is executed as a partner of joint venture clearly showing scope of works and percentage share of all partners of joint venture. To comply with the criteria, the share of bidder under the joint venture for similar works must be equal or exceeding the qualification criteria and requirement (Quantitative)(Doc Required)

  2 Completed Contracts   (20)

  1 Completed Contract   (10)

20
Number of on-going contracts of public sector Sports Facility Related works (i.e. Government or Semi Government organization or autonomous bodies or authorities) of minimum value of 70 % of the laydown cost of the project completed in the last 10 years. **NOTE** In case of Joint Venture, the working experience of leader of the Joint Venture shall be evaluated. **DOCUMENTATION REQUIREMENT** The bidder must upload Project Award Letter, Work Orders or Contract Agreement & completion Certificates and other documents necessary for confirming scope of works i.e. BOQs, IPC’s etc. The bidder must upload joint venture agreement in case of projects is executed as a partner of joint venture clearly showing scope of works and percentage share of all partners of joint venture. To comply with the criteria, the share of bidder under the joint venture for similar works must be equal or exceeding the qualification criteria and requirement (Quantitative)(Doc Required)

  2 On going Contracts   (20)

  1 On going Contract   (10)

20
**EQUIPMENT CAPABILITIES**
Concrete Batching Plant (1 m3 Capacity or above) (01) (Quantitative)(Doc Required)4
Mobile Concrete Transit Mixers (6 Cum Capacity or above) (02) (Quantitative)(Doc Required)

  02 nos.   (4)

  01 no.   (2)

4
Mobile Crane (01 no.) (Quantitative)(Doc Required)2
Generator (50KVA) (01 no.) (Quantitative)(Doc Required)2
Tractor Trolley/ Dumper (02 nos.) (Quantitative)(Doc Required)

  02 nos.   (2)

  01 NO.   (1)

2
Water Tanker (01 no.) (Quantitative)(Doc Required)1
**PERSONNEL CAPABILITIES**
Project Manager (01 No.) • BSc Civil Engineering • registration with PEC as Registered Engineer • At least 15 years’ of Professional Experience (Quantitative)(Doc Required)5
Site Engineer (Civil) (01 No.) • BSc Civil Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required)5
Site Engineer (E&M) • BSc Electrical/Mechanical/Mechatronic Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required)4
Material Engineer • BSc Civil/ Geological Engineering • registration with PEC as Registered Engineer • At least 10 years’ of professional experience (Quantitative)(Doc Required)2
Supervisor (Civil) • Diploma in Civil (DAE) • at least 5 years’ experience in building and road works (Quantitative)(Doc Required)1
Supervisor (E&M) • Diploma in Electrical (DAE) • at least 5 years’ experience in building and road works (Quantitative)(Doc Required)1
Quantity Surveyor • Diploma (DAE)/Relevant Certificate • at least 5 years’ experience in building project estimation (Quantitative)(Doc Required)1
Surveyor • Diploma in Civil (DAE) /Relevant Certificate • at least 5 years’ experience in building and road works (Quantitative)(Doc Required)1
**FINANCIAL SOUNDNESS**
Financial Resources (Contract/Project Specific Bank Credit Line) (Quantitative)(Doc Required)

  Contract/Project Specific Bank Credit Line PKR 224 Million or above   (15)

  Contract/Project Specific Bank Credit Line less than PKR 224 Million and more than or equal to PKR 210 Million   (14)

  Contract/Project Specific Bank Credit Line less than PKR 210 Million and more than or equal to PKR 196 Million   (13)

  Contract/Project Specific Bank Credit Line less than PKR 196 Million and more than or equal to PKR 182 Million   (12)

  Contract/Project Specific Bank Credit Line less than PKR 182 Million and more than or equal to PKR 168 Million   (11)

  Contract/Project Specific Bank Credit Line less than PKR 168 Million and more than or equal to PKR 154 Million   (10)

  Contract/Project Specific Bank Credit Line less than PKR 154 Million and more than or equal to PKR 140 Million   (9)

  Contract/Project Specific Bank Credit Line less than PKR 140 Million and more than or equal to PKR 126 Million   (8)

15
Average Annual Construction Turnover in last 3 years, evaluated through the bidder’s, Audited financial statements for the last three (03) years. (Quantitative)(Doc Required)

  Average Annual Construction Turnover of PKR 220 million or above.   (10)

  Average Annual Construction Turnover less than PKR 220 million and more than or equal to PKR 200 Million.   (9)

  Average Annual Construction Turnover less than PKR 200 million and more than or equal to PKR 180 Million.   (8)

  Average Annual Construction Turnover less than PKR 180 million and more than or equal to PKR 160 Million.   (7)

  Average Annual Construction Turnover less than PKR 160 million and more than or equal to PKR 140 Million.   (6)

  Average Annual Construction Turnover less than PKR 140 million and more than or equal to PKR 120 Million.   (5)

10

Jobs/Lots

Jobs Without Lots :

JobDelivery ScheduleQuantityBid Security
Wellness Complex
Address: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, IslamabadSchedule: 120 DaysQuantity: 1/job
1/job 14897491 PKR

Work Specifications and Market Rates

Jobs Without Lots :

Job: Wellness Complex

Specifications / Requirements:

Sr. NoRef. No.DescriptionUnitQtyRateRate in WordsAmount
1**RECEPTION/BILLIARD/TABLE-TENNIS**      
2**CIVIL WORKS**      
3**EARTH WORK (EXCAVATION & EMBANKMENT)**      
403-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft2.712266.7 33120.09
503-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft1.448155.5 11743.92
6 ii) With new earth excavated from outside lead upto one chain (30 m).1000 Cft1.8617545.5 32634.63
706-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
8(h)Ratio 1:3:6100 Cft0.2640827.38 10615.1188
9(i)Ratio 1:4:8100 Cft9.5635592.28 340262.1968
1006-06Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.).     
11 a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift.     
12 (2) Type B (nominal mix 1:1½: 3) Per Cft2045853.53 1745468.85
13 (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects: including all lead and lift.     
14 (2) Type B (nominal mix 1:1½: 3)      
15 (i) Upto 9" thick (Avg)Per Cft68823.28 55983.04
16 (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift.     
17 (2) Type B (nominal mix 1: 1½: 3)Per Cft762700.58 533841.96
1806-12Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars).     
19 (b) Deformed bars     
20 ii) Grade-60100kg118.728479.6 3380528.52
21**BRICK WORK**      
2207-05 (i)Pacca brick work in 1:4 C/S mortar in Ground floor100 Cft16.6742181.95 703173.1065
23**ROOFING**      
2409-15Khuras on roof 2'x2'x6" (600 x 600 x 150 mm)Each41228.55 4914.2
2509-35 (iii)Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick100 Sft17.3319751.6 342295.228
2609-46Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain     
27 i) 3 mm thickPer Sft1733125.15 216884.95
2809-48Providing and fixing false ceiling comprises of Gypsum board laminated sheet of size 2'x2'/2'x3'/ 3'x3'of specified design and thickness i/c cost of fixtures i.e galvanized angle 1" x 1" at wall sides, galvanized tee 1¼" x 1"and 1 ½” x 1” both at 4’ c/c ( made of Taiwan CKM or equivalent),hanging with G.I/Copper wire 16 SWG, G.I hook, Rawal Plug etc:complete in all respects as approved and directed by the Engineer Incharge      
29 iv) 12 mm thickPer Sft1535182.25 279753.75
30**FLOORING**      
3106-02Dry rammed brick or stone ballast, 1½" to 2" ( 40 mm to 50 mm) gauge.100Cft7.2814076.5 102476.92
3210-14Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm)100 Sft5.7621668.65 124811.424
3310-46-aProviding and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") Per Sft1535501.05 769111.75
3410-36Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge     
35 a) Full body Glazed tiles      
36 (iv) 600mmx 1200 mm (24"x48") Per Sft613501.2 307235.6
3710-47Providing and laying flooring with China Verona Marble having uniform texture (Spotless) of required size and specified thickness, with adhesive bond over 3/4" thick bedding of (1:2) cement sand mortor i/c the cost of matching sealer,cutting, grinding and chemical polishing complete in all respect as approved and directed by the Engineer Incharge. ii) 3/4" thick (12"x24"/12"x36") Per Sft120538 64560
3810-48Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Risers/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White Per Sft662015.75 133039.5
3910-49Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. Per Rft4239.9 1675.8
40**SURFACE RENDERING**      
4111-9(b)Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick100 Sft37.214923.45 183201.5745
4211-9(c)Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick100 Sft23.726585.35 156204.502
4311-12Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3100 Sft0.585624.75 3262.355
44**DOORS AND WINDOWS**      
4512-64Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge Each34569.55 13708.65
4612-30Providing and fixing approved quality rim lock adjustable over the style surface Each41680 6720
4712-13P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge.Per Sft81916.45 74232.45
4812-18Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc     
49 b) Deodar woodPer Sft811075.45 87111.45
5025-50Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick GlassPer Sft.1231799.55 221344.65
5125-55providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick GlassPer Sft.6282764.35 1736011.8
5225-52Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect.Per Sft.316538.3 170102.8
53**PAINTING AND VARNISHING**      
5413-31Preparing surface and painting emulsion paint :      
55 a) 1st coat100 Sft37.791760.75 66538.7425
56 b) 2nd & each subsequent coat.100 Sft75.581361.75 102921.065
5713-33, 13-31Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh     
58 i) 1st coat100 Sft1805271 948780
59 ii) 2nd & each subsequent coat.100 Sft3603038.4 1093824
6013-9Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m)100 Sft13.272821.7 37443.959
61**IRON WORKS**      
62**MISCELLANEOUS**      
6326-43Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge Sft 563812.7 71602.6
64**NON-SCHEDULED ITEM**      
65NSI-01Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects.Sft.615110 67650
66NSI-02Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer.Each350000 150000
67NSI-03Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area.Sft1186440 521840
68NSI-04Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects.Sft11862500 2965000
69**CAFÉ**      
70**CIVIL WORKS**      
71**EARTH WORK (EXCAVATION & EMBANKMENT)**      
7203-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft5.1212266.7 62805.504
7303-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft38155.5 24466.5
74ii)ii) With new earth excavated from outside lead upto one chain (30 m).1000 Cft0.2517545.5 4386.375
75**CONCRETE**      
7606-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
77(h)Ratio 1:3:6100 Cft0.340827.38 12248.214
78(i)Ratio 1:4:8100 Cft14.0635592.28 500427.4568
7906-06Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.).     
80 a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift.     
81 (2) Type B (nominal mix 1:1½: 3) Per Cft11091.33853.53 9466782.8949
82 (3) Type C (nominal mix 1: 2: 4)Per Cft54778.78 42054.12
83 (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects: including all lead and lift. (Water Tank Walls)     
84 (2) Type B (nominal mix 1:1½: 3)      
85 (i) Upto 9" thick (Avg)Per Cft230823.28 189354.4
86 (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift.     
87 (2) Type B (nominal mix 1: 1½: 3)Per Cft1527700.58 1069785.66
8806-12Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars).     
89 (b) Deformed bars     
90 ii) Grade-60100kg54928479.6 15635300.4
9106-32Providing and embedding 10" (250mm) wide PVC water stopper in expansion joints of RCC structures (Retaining walls, water tanks, Slabs) complete in all respect.     
92 ii) 10 mm thickRft60816 48960
93**BRICK WORK**      
9407-05 (i)Pacca brick work in 1:4 C/S mortar in Ground floor100 Cft119.0842181.95 5023026.606
9507-06-iPacca brick work in 1:4 C/S mortar.'Add extra labour on item No. 5 for brickwork in (i) first floor:- 100 Cft20.771793.45 37249.9565
96**ROOFING**      
9709-15Khuras on roof 2'x2'x6" (600 x 600 x 150 mm)Each41228.55 4914.2
9809-35 (iii)Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick100 Sft24.0419751.6 474828.464
9909-46Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain     
100 i) 3 mm thickPer Sft2404125.15 300860.6
10109-48Providing and fixing false ceiling comprises of Gypsum board laminated sheet of size 2'x2'/2'x3'/ 3'x3'of specified design and thickness i/c cost of fixtures i.e galvanized angle 1" x 1" at wall sides, galvanized tee 1¼" x 1"and 1 ½” x 1” both at 4’ c/c ( made of Taiwan CKM or equivalent),hanging with G.I/Copper wire 16 SWG, G.I hook, Rawal Plug etc:complete in all respects as approved and directed by the Engineer Incharge      
102 iv) 12 mm thickPer Sft1809182.25 329690.25
10309-50Providing and fixing Drywall Partition (4" thick) which consist of Gypsum Board sheet screwed to G.I Track U Channel (72mm x 32mmx 32mm x 0.50mm thick) fixed at top & bottom and G.I Studs (C-Channel) size (70mm x 34mm x 36mm x 0.50mm thick) equal vertical interval @ 2' C/C fit within the channel sections to form the frame work, including 12mm gypsum board (confirming to ASTM 1396) on both sides with infill insulation material (rockwool) i/c of jointing compound, self adhesive fiberglass tape for covering the joints between the drywall panels, corner angle bead, Smart Screws (3.5mm x 25mm), flex metal corner tape, for smooth and homogeneous look, grinding the exposed compound with abrasive paper, complete in all respects, as per specification and as approved by the Engineer inchargePer Sft138464.65 64121.7
104**FLOORING**      
10506-02Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge.100Cft9.5614076.5 134571.34
10610-14Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm)100 Sft6.4821668.65 140412.852
10710-35Mosaic dado or skirting with one part of cement and marble powder in the ratio of 3:1 and two parts of marble chips, laid over ½"(13 mm) thick cement plaster 1:3, including rubbing and polishing, complete with finishing: (a) using grey cement: i) 1/2"(13 mm) thick100 Sft4.520075.65 90340.425
10810-46-aProviding and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") Per Sft4500501.05 2254725
10910-36Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge     
110 a) Full body Glazed tiles      
111 (iv) 600mmx 1200 mm (24"x48") Per Sft1946501.2 975335.2
11210-47Providing and laying flooring with China Verona Marble having uniform texture (Spotless) of required size and specified thickness, with adhesive bond over 3/4" thick bedding of (1:2) cement sand mortor i/c the cost of matching sealer,cutting, grinding and chemical polishing complete in all respect as approved and directed by the Engineer Incharge. ii) 3/4" thick (12"x24"/12"x36") Per Sft69538 37122
11310-48Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White Per Sft4022015.75 810331.5
11410-49Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. Per Rft20539.9 8179.5
11510-50Extra cost for making hole in Marble slab for fixtures, Sink,burners,basin Vanities i/c cost of bevelling of internal edge as approved and directed by the Engineer Incharge. Each2980.7 1961.4
11610-51Providing and laying Prepolished Granite of specified thickness and shade of full width of approved quality laid with adhesive bond over 3/4" thick (1:2) cement sand mortor bed , complete in all respect as approved and directed by the Engineer Incharge.     
117 (i) 3/4" thick Per Sft811181.2 95677.2
11810-19Extra labour for each storey above ground, for mosaic, conglomerate, tiles, stone and wooden floor.(First floor)100 Sft30.081218.1 36640.448
119**SURFACE RENDERING**      
12011-9(b)Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick100 Sft72.084923.45 354882.276
12111-29Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30')100 Sft24.63659.45 16242.2535
12211-9(c)Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick100 Sft42.726585.35 281326.152
12311-29Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30')100 Sft24.06659.45 15866.367
12411-12Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3100 Sft4.175624.75 23455.2075
12511-29Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30')100 Sft3.58659.45 2360.831
126**DOORS AND WINDOWS**      
12712-13P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge.Per Sft77916.45 70566.65
12812-18Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc     
129 b) Deodar woodPer Sft771075.45 82809.65
13012-64Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge Each24569.55 9139.1
13112-30Providing and fixing approved quality rim lock adjustable over the style surface Each41680 6720
13225-50Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick GlassPer Sft.1171799.55 210547.35
13325-55providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick GlassPer Sft.17522764.35 4843141.2
13425-52Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect.Per Sft.876538.3 471550.8
135**PAINTING AND VARNISHING**      
13613-31Preparing surface and painting emulsion paint :      
137 a) 1st coat100 Sft76.251760.75 134257.1875
138 b) 2nd & each subsequent coat.100 Sft152.511361.75 207680.4925
13913-31Extra labour for painting, varnishing, etc. from 20' (6.10 m)height and above, for every additional 10' (3.05 m) height,or part thereof, requiring scaffolding100 Sft28.21259.85 7330.3685
14013-33, 13-31Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh     
141 i) 1st coat100 Sft6.895271 36317.19
142 ii) 2nd & each subsequent coat.100 Sft13.783038.4 41869.152
14313-9Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m)100 Sft23.82821.7 67156.46
144**IRON WORKS**      
14525-38Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer InchargePer Rft303387.45 101623.5
146**MISCELLANEOUS**      
14726-43Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge Sft 607712.7 77177.9
148**NON-SCHEDULED ITEM**      
149NSI-01Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects.Sft.1635110 179850
150NSI-02Supply and installation of Wood Plastic Composite (WPC) ceiling panels, manufactured from weather‑resistant composite material, designed to be durable, moisture‑proof, termite‑proof, and low maintenance. Installation shall include all necessary fixtures, fasteners, and accessories, and complete in all respects as per drawings and as directed by The Engineer’s instructions.Sft.24991000 2499000
151NSI-03Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects.Sft.1621020 165240
152NSI-04Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer.Each350000 150000
153NSI-05Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area.Sft3339440 1469160
154NSI-06Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects.Sft33392500 8347500
155**GYM**      
156**CIVIL WORKS**      
157**EARTH WORK (EXCAVATION & EMBANKMENT)**      
15803-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft26.1812266.7 321142.206
15903-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft18.378155.5 149816.535
160ii)ii) With new earth excavated from outside lead upto one chain (30 m).1000 Cft3.6217545.5 63514.71
161**CONCRETE**      
16206-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
163(h)Ratio 1:3:6100 Cft1.1840827.38 48176.3084
164(i)Ratio 1:4:8100 Cft25.5235592.28 908314.9856
16506-06Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.).     
166 a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects. including all lead and lift.     
167 (2) Type B (nominal mix 1:1½: 3) Per Cft10116853.53 8634309.48
168 (3) Type C (nominal mix 1: 2: 4)Per Cft13778.78 10124.14
169 (b) (ii) Reinforced cement concrete in retaining/ Shear walls laid in situ or precast laid in position, or prestressed members cast in situ (Formwork on both sides) , complete in all respects:including all lead and lift.     
170 (2) Type B (nominal mix 1:1-1/2:3)     
171 (i) Upto 9" thick (Avg)Per Cft1971823.28 1622684.88
172 (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:- including all lead and lift.     
173 (2) Type B (nominal mix 1: 1½: 3)Per Cft5617700.58 3935157.86
174 Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars).     
175 (b) Deformed bars     
176 ii) Grade-60100kg682.728479.6 19443022.92
177 Providing and embedding 10" (250mm) wide PVC water stopper in expansion joints of RCC structures (Retaining walls, water tanks, Slabs) complete in all respect.     
178 ii) 10 mm thickRft122816 99552
179**BRICK WORK**      
18007-4(i)Pacca brick work in 1:4 C/S mortar in foundation and upto plinth top:-100Cft0.5441153.25 22222.755
18107-05 (i)Pacca brick work in 1:4 C/S mortar in Ground floor100 Cft57.1342181.95 2409854.8035
18207-06-iPacca brick work in 1:4 C/S mortar.'Add extra labour on item No. 5 for brickwork in (i) first floor:- 100 Cft19.131793.45 34308.6985
183**ROOFING**      
18409-15Khuras on roof 2'x2'x6" (600 x 600 x 150 mm)Each41228.55 4914.2
18509-35 (iii)Providing and laying roof insulation, comprising of single layer of tiles 9"x4½"x1½" (225x113x40 mm) grouted with cement sand mortar 1:3 laid over 2" (50 mm) thick earth (including mud plaster) over thermopore sheet, over polythene sheet 300 gauge over a layer of bitumen, complete in all respects:- iii) Thermopore sheet 1" (25 mm) thick100 Sft46.8419751.6 925164.944
18609-46Providing and applying torch-on plain water proofing bitumenous membrane of specified thickness (made of Roof-Grip/ Euro Bit) duly lapped/connected by heating with Torch over ps-6 primer i/c preparation/smoothen the surface complete in all respect as approved and directed by the Engineer Incharge a) Plain     
187 i) 3 mm thickPer Sft7410125.15 927361.5
188**FLOORING**      
18906-02Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge.100Cft12.5214076.5 176237.78
19010-14Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm)100 Sft8.721668.65 188517.255
19110-16Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick100 Sft3.916609.8 64778.22
19210-35Mosaic dado or skirting with one part of cement and marble powder in the ratio of 3:1 and two parts of marble chips, laid over ½"(13 mm) thick cement plaster 1:3, including rubbing and polishing, complete with finishing: (a) using grey cement: i) 1/2"(13 mm) thick100 Sft220075.65 40151.3
19310-39Providing and laying 1" thick terrazo tile for specified colour & size full body, best quality with minimum 5000 PSI in approved design with adhesive bond over 3/4" thick 1:3 cement plaster i/c the cost of sealer for finishing the joints i/c cutting, grinding, rubbing, filling Complete in all respect as approved and directed by the Engineer incharge. (Without Polishing) b) Size 24"x24"x1" ii) ColouredSft1414405.05 572740.7
19410-46-aProviding and laying superb quality Porcelain glazed tiles flooring of Master/ Stile brand or approved equivalent manufacturer of specified size in approved design,Color and Shade with adhesive/bond over 3/4"thick (1:3) cement plaster i/c the cost of sealer for finishing the joints i/c cutting grinding complete in all respect as approved and directed by the Engineer Incharge. a) Full body Glazed tiles (iv) 600mmx 1200 mm (24"x48") Per Sft3510501.05 1758685.5
19510-36Providing and laying superb quality Porcelain glazed tiles of Master/ Stile brand or approved equivalent manufacturer, skirting/dado of specified size, Color and Shade with adhesive/ bond over 1/2"thick (1:2) cement plaster i/c the cost of and sealer for finishing the joints, cutting grinding complete in all respect as approved and directed by the Engineer Incharge     
196 a) Full body Glazed tiles      
197 (iv) 600mmx 1200 mm (24"x48") Per Sft4341501.2 2175709.2
19810-48Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Risers/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White Per Sft3552015.75 715591.25
19910-49Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. Per Rft18139.9 7221.9
20010-50Extra cost for making hole in Marble slab for fixtures, Sink,burners,basin Vanities i/c cost of bevelling of internal edge as approved and directed by the Engineer Incharge. Each5980.7 4903.5
20110-51Providing and laying Prepolished Granite of specified thickness and shade of full width of approved quality laid with adhesive bond over 3/4" thick (1:2) cement sand mortor bed , complete in all respect as approved and directed by the Engineer Incharge.     
202 (i) 3/4" thick Per Sft841181.2 99220.8
20310-19Extra labour for each storey above ground, for mosaic, conglomerate, tiles, stone and wooden floor.(First floor)100 Sft0.911218.1 1108.471
204**SURFACE RENDERING**      
20511-9(b)Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick100 Sft79.484923.45 391315.806
20611-29Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30')100 Sft36.29659.45 23931.4405
20711-9(c)Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick100 Sft54.846585.35 361140.594
20811-29Extra for lime, mud or cement plaster and pointing from 20' (6.00 m) and above for each additional 10' (3.00 m) height or part thereof. (20'~30')100 Sft26.88659.45 17726.016
20911-12Cement plaster 3/8" (10 mm) thick under soffit of R.C.C.roof slabs only, upto 20' height. b) 1:3100 Sft6.065624.75 34085.985
210**PAINTING AND VARNISHING**      
21113-31Preparing surface and painting emulsion paint :      
212 a) 1st coat100 Sft30.661760.75 53984.595
213 b) 2nd & each subsequent coat.100 Sft61.321361.75 83502.51
21413-33, 13-31Providing and applying weather shield paint of approved quality on external surface of building including preparation of surface, application of primer complete in all respect: upto 20' heigh     
215 i) 1st coat100 Sft9.35271 49020.3
216 ii) 2nd & each subsequent coat.100 Sft18.63038.4 56514.24
217**DOORS AND WINDOWS**      
21812-64Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge Each84569.55 36556.4
21925-50Providing and fixing all types of partly fixed and partly openable glazed anodised/ powder coated aluminium doors 1.6mm, using delux section of M/s Al-Cop or Pakistan Cables, having chowkat frame of size 40 x 100 mm (1½" x 4") and leaf frame of 60x40mm (2½"x1½") wide sections including the cost of specified thickness tempered glass with aluminium triangular gola and rubber gasket to support the glass and leaf edging, using approved standard fittings, locks, 3" (75 mm) wide long handles etc., and hardware any required as approved by the Engineer in-charge. ii) 8mm thick GlassPer Sft.731799.55 131367.15
22025-55providing and fixing 2 mm thick Double glazed aluminium windows of anodize / powder coated partly fixed and party sliding using deluxe section of 100mm x 40mm x2 mm using frame (70501) at bottom, (70502) at Top & Side made of Pakistan Cables/Alcop or approved equivalent manufacturer having Leaf Frame size 31mm x 60mm x2 mm (70506) at Top & Bottom, 35mm x 60mm x2 mm (70505) at center and 35mm x 60mm x2 mm(70503) at sides , fixing one side Tinted and one side clear double glass, and air tight using double tape, chemical strips, Silicon using approved latches, wheels for channel, stopper, brush channel angle joint and hardware etc.( excluding the cost of Fly Proofing). Complete in all respect as approved and directed by the Engineer Incharge. b) 6mm thick GlassPer Sft.10012764.35 2767114.35
22125-61P/F Iron door comprising of specified leaves made of 1-1/4”x1-1/4”x3/16" MS angle iron for leaf frame, diagonal and horizontal braces duly welded with MS. sheet 18-SWG i/c the cost of sliding bolt, tower bolt and painting 3-coats but excluding the cost of Chowkat complete in all respect as approved and directed by the Engineer incharge (i) Single LeafSft741083.75 80197.5
22212-05Providing and fixing 1st class solid wood wrought joinery in panelled or panelled and glazed doors and windows of specified thickness with 1" thick solid wood panels with step and 1-1/2"x2-1/2" beadings all around the panels i/c the cost of Tower bolt and handles complete in all respect (Excluding the cost of sliding bolt,lock and chowkats (frame), etc.) as approved and directed by the Engineer Incharge b) Ash wood Door (i) 2" thick (50 mm)Sft1573753.45 589291.65
22312-13P/F 1-1/2" thick solid flush door comprising of 2.5 mm thick Deodar/Ash/Oak ply with grooves , compressed over 2.5 mm thick commercial ply over 1" thick packing wood in style and rails under proper pressure i/c the cost of nails, tower bolt , handles, glue, sawing charges and lacquar polishing to show the grains of ply properly, sand papering and 3/8" thick matching wooden lipping as approved and directed by the Engineer Incharge.Per Sft140916.45 128303
22412-18Providing and fixing 3"x4-1/2" chowkat for doors, windows and C. windows, including holdfast, etc     
225 b) Deodar woodPer Sft2971075.45 319408.65
22625-52Providing and fixing Aluminum Fly screen comprising of Fiber / Aluminum wire guaze (Malasian) fixed in aluminum frame of approved manufacturer / powder coated of size 1-1/2"x1/2" and 1.6mm thick with rubber gasket i/c cost of Hardwares as approved and directed by the engineer incharge. complete in all respect.Per Sft.501538.3 269688.3
227**PAINTING AND VARNISHING**      
22813-9Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m)100 Sft51.222821.7 144527.474
229**IRON WORKS**      
23025-38Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer InchargePer Rft763387.45 257446.2
231**MISCELLANEOUS**      
23226-43Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge Sft 1105312.7 140373.1
233**NON-SCHEDULED ITEM**      
234**MISCELLANIES WORKS**      
235NSI-01Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects.Sft.2494110 274340
236NSI-02Supply and installation of Wood Plastic Composite (WPC) ceiling panels, manufactured from weather‑resistant composite material, designed to be durable, moisture‑proof, termite‑proof, and low maintenance. Installation shall include all necessary fixtures, fasteners, and accessories, and complete in all respects as per drawings and as directed by The Engineer’s instructions.Sft.8301000 830000
237NSI-03Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects.Sft.80321020 8192640
238NSI-04Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer.Each350000 150000
239NSI-05Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area.Sft4086440 1797840
240NSI-6Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects, and directions of the Engineer-in-Charge, Sft40862500 10215000
241NSI-7Supply and installation of MR (Moisture Resistant) grade board lockers, complete with internal shelves as per requirement, finished with approved laminate finish, including premium quality hinges and hardware, such as handles, locks, screws, and fittings. and directions of The Engineer.Sft2646875 1815000
242NSI-8Supply and installation of high-density gym rubber flooring, made from durable shock-absorbing rubber, slip-resistant, impact-resistant, and noise-reducing. Suitable for heavy gym equipment and high-traffic fitness areas. Installed complete with proper leveling and finishing.. and directions of The Engineer.Sft45824200 19244400
243NSI-9Three coats of Matt Enamel Paint of approved colour, including surface preparation by provision of a film with Alkali resisting primer to form smooth base for paint, including sand papering etc. , filling where required, etc. complete.Sft348385 296055
244**PEDAL COURT**      
245**CIVIL WORKS**      
246**EARTH WORK (EXCAVATION & EMBANKMENT)**      
24703-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft0.0612266.7 736.002
24803-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft0.058155.5 407.775
249**CONCRETE**      
25006-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
251(f)Ratio 1:2:4100 Cft7.6847998.78 368630.6304
252(h)Ratio 1:3:6100 Cft0.0840827.38 3266.1904
253**FLOORING**      
25410-16Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick100 Sft21.416609.8 355449.72
255**NON-SCHEDULED ITEM**      
256NSI-01Providing, supplying and fixing of MS STEEL Square Tube for Corner Columns 5 inch, (Triangular Shape) 10gauge Thick.Supply of MS STEEL Square Tube for Cross 4 inch x 4 inch x12 gauge Thick for Top Sections same as bottom section. Supply of MS STEEL Rectangular Tube for Mesh Frame 3 inch x 1.5 inch x 12 gauge Thick. Supply and Fixing of 2 inch x 2 inch x 8 gauge Wire Mesh Black Paint. Supply of Floodlight Column MS STEEL Square Tube 10 ft Long 3 inch x 1.5 inch 14 gauge Thick. Supply & fixing with complete accessories with 10 mm thick metal plates and fixtures. (Botts, Elastic Washers, Rubber Mats) etc.complete in all respects.Sft.21781186 2583108
257NSI-02Providing, supplying and fixing Ghani Glass12 mm thick Tempered glass with complete accessories etc.complete in all respects.Sft.12611814 2287454
258NSI-03Providing, supplying and fixing Bellin Turf Vietnam / CC Gras Color Blue, Green, TerracottaThickness 12 mm Backing: PU backing Material: PE Monofilament +PP texturized Yarn (Curly) Dtex: 9600 Also Include Installation of Silica Sand (2 tons) Waterproof Turf Cover complete in all respects.Sft.21781084 2360952
259NSI-04Providing, Supplying and fixing Paddle Net Length: 9830 mm, Height 920mm Material: PP, Thickness: 3mm Mesh: 43mm x 43mm Net Column 4 in x 4 in 12 gauge pole With pully and tightner Height: 920 mm Column Size: 80 mm x 80 mm x 3 mm Leather Poshish with branding (Complete Set) complete in all respects.Set.1221250 221250
260NSI-05Providing, Supplying and fixing Digital Scoring BoardNo173750 73750
261NSI-06Providing and Supplying Rackets and Balls 2x Padel Rackets 12k 2x Containers and Padel balls Racket hanger complete in all respects.No1147500 147500
262**BADMINTON**      
263**CIVIL WORKS**      
264**EARTH WORK (EXCAVATION & EMBANKMENT)**      
26503-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft3.6612266.7 44896.122
26603-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft2.018155.5 16392.555
267ii)ii) With new earth excavated from outside lead upto one chain (30 m).1000 Cft1.9517545.5 34213.725
268**CONCRETE**      
26906-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
270(h)Ratio 1:3:6100 Cft0.2640827.38 10615.1188
271(i)Ratio 1:4:8100 Cft12.3435592.28 439208.7352
27206-06Providing and laying reinforced cement concrete (including prestressed concrete), using coarse sand and screened graded and washed aggregate, in required shape and design, including forms, moulds, shuttering, lifting, compacting, curing, rendering and finishing exposed surface, complete (but excluding the cost of steel reinforcement, its fabrication and placing in position, etc.).     
273 a.) (i) Reinforced cement concrete in roof slab, beams, columns lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects.including all lead and lift.     
274 (2) Type B (nominal mix 1:1½: 3) Per Cft3358853.53 2866153.74
275 (c) (iii) Reinforced cement concrete in slab of rafts / strip foundation, base slab of column and retaining walls; etc and footing beams, other structural members other than those mentioned in 6(a) (i)&(ii) above not requiring form work (i.e. horizontal shuttering) complete in all respects:-including all lead and lift.     
276 (2) Type B (nominal mix 1: 1½: 3)Per Cft1152700.58 807068.16
27706-12Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings, including cost of binding wire and labour charges for binding of steel reinforcement (also includes removal of rust from bars).     
278 (b) Deformed bars     
279 ii) Grade-60100kg14828479.6 4214980.8
280**BRICK WORK**      
28107-05 (i)Pacca brick work in 1:4 C/S mortar in Ground floor100 Cft11.7942181.95 497325.1905
282**FLOORING**      
28306-02Dry rammed brick or stone ballast, 1½" to 2"( 40 mm to 50 mm) gauge.100Cft7.7214076.5 108670.58
28410-14Cement concrete tiles laid in 1:2 cement mortar, over 3/4" (20 mm) thick bed of cement mortar 1:2:- (a) 12"x12"x1" (300 x 300 x 25 mm)100 Sft5.7621668.65 124811.424
28510-48Providing and laying 3/4" thick full width Prepolished Marble slab for Vanities / Shelves / Treads/Window Cills , having Uniform texture (Spotless) with adhesive bond over 3/4" thick (1:2) cement sand mortor i/c the cost of matching sealer complete in all respects as approved and directed by the Engineer Incharge ii) Ziarat White Per Sft1142015.75 229795.5
28610-49Extra for Bevelling charges of marble edge in approved design complete in all respects i/c the cost of Carborandam disc as approved and directed by the Engineer Incharge. Per Rft4239.9 1675.8
28710-48Providing, laying and jointing Premium Quality Imported HDF Laminated Wooden Flooring (sustainable certification compliance )of approved color, shade, size and surface finish having properties of water resistance, UV resistance, stain resistance, scratch resistance, abrasion resistance complying EN 438, including the cost of edging & underlayment (min 2 mm polyethylene / EVA ), etc., complete in all respect as per approved specifications and as approved by the Engineer incharge. ii 12mm thick (AC5 - cycle>6000) Per Sft1665909.7 1514650.5
288**SURFACE RENDERING**      
28911-9(b)Cement plaster 1:4 upto 20' (6.00 m) height: b) ½" (13 mm) thick100 Sft18.984923.45 93447.081
29011-9(c)Cement plaster 1:4 upto 20' (6.00 m) height: c) ¾" (20 mm) thick100 Sft19.546585.35 128677.739
291**DOORS AND WINDOWS**      
29212-64Providing and fixing Imported Mortise Lever Handle Lock with back plate (Machine, Cylinders, Lever Handles (Pair) and backplate (Pair)) of approved quality, design & finish, including the cost of all accessories to complete the job as shown on drawing and as per specification, complete in all respect, as approved and directed by the Engineer Incharge Each14569.55 4569.55
293**PAINTING AND VARNISHING**      
29413-5dPreparing surface and painting guard bars, gates of iron bars, gratings, railing (including standards, braces, etc.) and in similar open work:-      
295 i). Priming coat100 Sft18.591274.1 23685.519
296 ii). each subsequent coat of paint (2 coats)100 Sft37.18850.6 31625.308
29713-9Bitumen coating to plastered or cement concrete surface:- i) 20 lbs. per 100 Sft. (9.07 Kg per Sq.m)100 Sft16.52821.7 46558.05
298**IRON WORKS**      
29925-10Fabrication of heavy steel work, with angle, tees, flat iron round iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, but excluding erection in position100 Kg56.2435334.3 1987201.032
30025-11Erection and fitting in position iron trusses, staging of water tanks, etc.100 Kg56.242042.95 114895.508
30125-38Providing and fixing 2'-9" high stair railing comprising of non magnetic (304) Stain less steel 2" dia pipe railing of 18 SWG welded with vertical posts of 2" dia stainless steel round/ Squar pipe/ Tong (chimta) @ 2-ft c/c fixed on alternate steps with 3" long steel screws and brass rawal plugs , 3-Nos diagonal stainless steel pipes of 1/2" dia passes through goties fixed on vertical post, i/c stainles steel welding, fixing & polishing complete in all respects as approved and directed by the Engineer InchargePer Rft153387.45 50811.75
30225-69Providing and fixing 12 mm Tempered Glass Door frameless comprising of aluminium H-section (D48) at bottom, H-type S.S framless handles both side (approved), top pivot hinges, bottom concealed floor machine hinges, s.s patch fitting, D glass door lock (approved) and all the cost of using approved standard fittings, accessories etc., and hardware any required, as shown on drawings, complete in all respect as per Specifications,as approved by the Engineer. Per Sft 402184.75 87390
303**MISCELLANEOUS**      
30426-43Spraying termite proofing by using liquid FMC/ Biflex/ Terminex Exin/ Ms Hextar or equivalent @ specified suspension concenterate (SC), Mixing Ability-HEXTAR with Ratio (1:250) = 540 Sft or equivalent approved liquid applying with shower and certificate will be provided by the contractor for 10-years complete in all respect .as approved by the Engineer Incharge Sft 591912.7 75171.3
305**NON SCHEDULE ITEMS**      
306**IRON WORKS**      
307NSI-01Provide & fix expended metal 1/2" to 3/4", 22 guage fixed walls or on area as required and specified on drawings with steel nails with washers complete in all respects.Sft.385110 42350
308NSI-02Providing and fixing Aluminium 15 mm thick 2' x 2' mineral fiber acoustical tile false ceiling (with surface pattern / design /texture), 4 sides revealed with bevel edges of approved manufacturer with recommended adjustable suspension system and accessories in approved colour exposed surfaces, complete in all respects.Sft.16651020 1698300
309NSI-03Supplying and installation of sandwich roofing panels of 2" (50 mm) overall thickness, comprising outer sheet of 24 SWG pre-painted galvanized steel (PPGI) and inner sheet of 26 SWG PPGI, factory-bonded with rigid insulation core of PUF/PIR/EPS of density 40 ± 2 kg/m³, modular width approx. 1000 mm, lengths as per site requirement, with tongue-and-groove/cam-lock jointing system, complete with ridge, flashing, fasteners, sealants, and trims, ensuring thermal conductivity ≤ 0.024 W/make, sound insulation ≥ 25 dB, and fire resistance Class B or equivalent, including all cutting, fixing finishing and complete in all respects as per drawings and as directed by The Engineer’s instructions.Sft.18591560 2900040
310NSI-04Supply, fabrication and installation of illuminated logo signage to be mounted at the top of building, as per approved design, drawings and Specifications. The work shall include fabrication of logo letters and symbols in approved size and proportions using MS/Aluminum framework, clad with acrylic/ACP or equivalent approved material, complete with internal LED illumination system to achieve uniform backlit/front-lit effect, including diffusers, wiring, drivers and power supply units, structural supporting frame, base plates, brackets, anchor bolts (chemical/mechanical), and all necessary fixing arrangements designed to withstand wind loads and external environmental conditions at height, anti-corrosion treatment (primer, paint or powder coating), weatherproofing, sealing, and finishing and all incidental works shall be included, complete in all respects, as per approved shop drawings and as directed by the Engineer.Sft.150000 50000
311NSI-05Providing and applying high-quality Decorative Acrylic Texture Coating (Stucco Finish) Italian texture paint finish on prepared internal/external wall surfaces, including surface cleaning, crack filling, putty work where required, application of primer, and textured coating to achieve a uniform decorative stucco finish. The work shall include all materials, labor, tools, scaffolding, surface preparation, and finishing coats complete in all respects, as per manufacturer's specifications, approved samples, and directions of the Engineer-in-Charge. Measurement shall be made on the finished surface area.Sft977440 429880
312NSI-06Providing, supplying and fixing 25 mm thick decorative natural stone wall cladding panels with a CNC-carved 3D pattern, of approved type, color, and finish. The work shall include fixing the panels using an approved stainless steel mechanical anchoring system, including cutting, drilling, edge finishing, joint treatment, sealant, scaffolding, transportation, labour, and all necessary hardware and accessories required for installation complete with all respect as per drawings, specifications, and as approved by the Engineer-in-Charge. Complete in all respects.Sft9772500 2442500
313NSI-07Structural/glazing system with 2 mm thick and 100mm wide powder coated (in approved colour) base frame system as per the recommendations of the specialized facade designer and agreed by the approved manufacturer and stainless steel fittings using insulated glazing unit (IGU) system comprising of 6mm thick imported Low-E glass of approved color/shade having Low-E coating on surface no. 2 (inside the outer glass) and 6mm thick clear tempered glass (inner glass), with 12 mm wide aluminum spacers Low-E glass shall have a maximum of 3.7 U-factor with 0.45 solar heat gain coefficient. The glass to be used shall be from Pilkington/Guardian or an approved equivalent manufacturer. Doors in the curtain wall shall be of 12 mm thick Low-E tempered glass of approved color/shade, having handles 1500 mm long with 38mm dia & 2 mm wall thickness pipes of SS-316 brushed finish. All joints between the panels shall be sealed with minimum clear silicon sealant from Dow Corning of an approved equivalent. The Contractor shall submit shop drawings for the approval of the Engineer.Sft8413800 3195800
314**BOX CRICKET /FUTSAL GROUND**      
315**CIVIL WORKS**      
316**EARTH WORK (EXCAVATION & EMBANKMENT)**      
31703-21Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling in layers around structure with excavated earth, watering and ramming lead upto one chain (30 m) lift upto 5 ft (1.5m) 2) a) By Excavator (iii) Hard soil or Soft murum 1000 Cft0.112266.7 1226.67
31803-15Filling, watering and ramming earth under floors. i) with surplus earth from foundation, etc.1000 Cft0.068155.5 489.33
319**CONCRETE**      
32006-05Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
321(f)Ratio 1:2:4100 Cft15.0847998.78 723821.6024
322(h)Ratio 1:3:6100 Cft0.1240827.38 4899.2856
323**FLOORING**      
32410-16Providing and laying topping of cement concrete 1:2:4,including surface finishing and dividing in panels (i) 3"(75 mm) thick100 Sft42.6416609.8 708241.872
325**NON SCHEDULE ITEMS**      
326NSI-01Providing, supplying and fixing 3 inch round poles galvanized for vertical columns 12 gauge 22 ft height 2 inch round poles galvanized for horizontal connections 2 lines on after 10 ft height Ground fixing with J-bolt system 3 ft deep and 10 mm thick iron base plates Top net tension iron cable 9 mm etc.complete in all respects.Sft.4264676 2882464
327NSI-02Providing, supplying and fixing Iron Mesh / Net Coverage Iron mesh with 2 inch holes on all four sides diamond shape Height 20 ft 10 guage UV coated fiber net on top Solid CNC designed gate etc.complete in all respects.Sft.1450087 1261500
328NSI-03Providing, supplying and fixing Imported turf for cricket pitch Color: Blue, Green, Terracotta Pile height 12 mm PU backing PE Monofilament + PP texturized Yarn (Curly) Turf for Ground Multiparous Grass for futsal and cricket Color: Lite and Dark Green Pile height 30 mm 20 stiches UV coated complete in all respects.Sft.4264606 2583984
329NSI-04Providing and Supplying Play Equipment 2 x Bats Set of Wickets 2 x BallsNo136875 36875
330**INTERNAL ROADS**      
331**CIVIL WORKS**      
33203-25/P-26Compaction of earthwork with power road roller, includingploughing, mixing, moistening earth to optimum moisture content in layers, etc. complete     
333 i) 95% to 100% maximum modified AASHTO dry density.P.CUM385.44864633660.05 23146.191212477
33406-05/P-35Cement concrete plain including placing, compacting, finishing and curing complete (including screening and washing of stone aggregate) including all lead and lift.     
335 (f) Ratio 1: 2: 4P.CUM192.72432316816945.35 3265781.1095949
336 18-3 /P-106a) Providing and laying sub-base course of stone product of approved quality and grade, including placing, mixing, spreading and compaction of sub-base material to required depth, camber, grade to achieve 100% maximum modified AASHO dry density, including carriage of all material to site of work except gravel and. aggregate. i/c lead ii) Crushed stone aggregate. P.CUM254.396106581763669.65 933544.67251776
33710-44/p-65Providing and laying Polygon Pavers, having 7000 PSI crushing strength of approved manufacturer, 60mm thick, over 2" to 3" sand cushion i/c grouting with sand in joints i/c finishing to require slope,in pattern as approved by Engineer Incharge. Complete in all respect. (Grey & Combination of any Colour)Per Meter1264.91401486991873 2369183.9498513
338**PLUMBING WORKS**      
339**BILLIARD ROOM**      
340**SANITARY FIXTURES AND FITTINGS**      
34119 / 3Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge.     
342BOne Piece     
343iii.PORTA HD 102N Toilet Cito with Hydraulic Seat CoverEach259851.1 119702.2
34419 / 7Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc.     
345(i)white with pedestalEach212051.55 24103.1
34619 / 16Providing and fixing, chromium plated soap dish.Each2981.6 1963.2
34719 / 9 / ii page 119Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steelEach24229.4 8458.8
34819 / 18Providing and fixing, chromium plated toilet paper holder.Each21271.45 2542.9
34919 / 19 / iProviding and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") diaEach21337.2 2674.4
35019 / 20Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality.Each21546.2 3092.4
35119/21Providing and fixing glass shelf 60x13 cm (24"x5"), with 5mm thick glass:- i) with chromium plated brackets and railing.Each21701.7 3403.4
35219 / 27/ iiProviding and fixing chromium plated bib cock 1.5cm (1/2")Each21588 3176
35319 / 28Providing and fixing chromium plated Tee stop cock 15mm (1/2")Each102068 20680
35419 / 52Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge     
355iiLever Type Basin MixerEach26707 13414
356iiiDouble Bib CockEach21907 3814
357vMuslim showerEach22387 4774
358viIBottle TrapEach21487 2974
35919 / 7 / ii page 118Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) Each10712.8 7128
36019 / 55 page 117Providing/fixing Gas water heater (Geyser) of specified capacity, comprising of water tank made of 14 SWG steel sheet and cover with 20 SWG MS sheet, best quality make of Corona/Ambassador / Super Asia/Canon or approved equivalent manufacturer i/c the cost of non return valve,imported thermostate,G.I. accessories, safety valve and making connection with existing water supply pipe line complete in all respects as approved and directed by the Engineer Incharge     
361(i)06 GallonsEach219730.05 39460.1
362**WATER SUPPLY PIPES AND FITTINGS**      
36323 / 33 / bProviding, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20     
364ii25mm diaRft10099.7 9970
365iii32mm diaRft50158.25 7912.5
366iv40mm diaRft20241.75 4835
36723 / 42Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge.     
368a-ii3/4" dia Brass Threaded ValvesEach13510 3510
369a-iii1" dia Brass Threaded ValvesEach15025.6 5025.6
37023 / 45Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic     
371a-ii3/4 inches Each11896 1896
372**SOIL, WASTE AND VENT PIPES & FITTINGS**      
37319 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
374iii50mmRft20103.95 2079
375iv82mmRft50160.6 8030
376v110mmRft30254.3 7629
377vi160mmRft10493.4 4934
37819 / 49Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge.     
379b-iMulti-Trap 4"Each21436.1 2872.2
380c-iiVent Cowel 3"Each2386.1 772.2
38119 / 12 page 119Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge.     
382(i)4" DiameterEach21254.95 2509.9
38321 / 5Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects:     
384a)with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type.Each217212.95 34425.9
385**STORM DRAINAGE PIPES & FITTINGS**      
38619 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
387v110mmRft30254.3 7629
38819 / 13 page 119Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge.     
389(i)4" DiameterEach21284.8 2569.6
390**NON-SCHEDULED ITEMS**      
391 **GENERAL NOTE **     
392 Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer.     
393NS-01CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects.Each22170 4340
394**PLUMBING WORKS**      
395**CAFÉ / CIGAR ROOM**      
396**SANITARY FIXTURES AND FITTINGS**      
39719 / 3Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge.     
398BOne Piece     
399iii.PORTA HD 102N Toilet Cito with Hydraulic Seat CoverEach259851.1 119702.2
40019 / 7Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc.     
401(i)white with pedestalEach212051.55 24103.1
40219 / 8Providing and fixing stainless steel sink with drain board, size 120x60 cm (48"x24") including bracket set, waste pipe and waste coupling.Each215806.95 31613.9
40319 / 30Providing and fixing, chromium plated mixing valve, for wash hand basin, sink or shower.Each23950 7900
40419 / 16Providing and fixing, chromium plated soap dish.Each2981.6 1963.2
40519 / 9 / ii page 119Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steelEach24229.4 8458.8
40619 / 18Providing and fixing, chromium plated toilet paper holder.Each21271.45 2542.9
40719 / 19 / iProviding and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") diaEach21337.2 2674.4
40819 / 20Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality.Each21546.2 3092.4
40919/21Providing and fixing glass shelf 60x13 cm (24"x5"), with 5mm thick glass:- i) with chromium plated brackets and railing.Each21701.7 3403.4
41019 / 27/ iiProviding and fixing chromium plated bib cock 1.5cm (1/2")Each21588 3176
41119 / 28Providing and fixing chromium plated Tee stop cock 15mm (1/2")Each82068 16544
41219 / 52Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge     
413iiLever Type Basin MixerEach26707 13414
414iiiDouble Bib CockEach21907 3814
415vMuslim showerEach22387 4774
416viIBottle TrapEach21487 2974
41719 / 7 / ii page 118Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) Each8712.8 5702.4
41819 / 56 page 117Supply & Installation of Duel (Electric and Gas Water Heaters) with factory-installed pressure relief valve, adjustable water temperature control thermostate, Copper connections for specific capacity having leaving waterr temprature 140 deg F & working pressure 15 PSI, Ambasador/Canon or approved manufacturer i/c cost of all accessories to complete the job as per specifications and standards & making connection, complete in all respect as approved and directed by Engineer Incharge.     
419ii55 GallonsEach183161.5 83161.5
420**WATER SUPPLY PIPES AND FITTINGS**      
42123 / 33 / bProviding, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20     
422ii25mm diaRft20099.7 19940
423iii32mm diaRft50158.25 7912.5
424iv40mm diaRft30241.75 7252.5
425v50mm diaRft10347.1 3471
426vi63mm diaRft50541.3 27065
42723 / 42Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge.     
428a-ii3/4" dia Brass Threaded ValvesEach63510 21060
429a-iii1" dia Brass Threaded ValvesEach45025.6 20102.4
430a-iv1-1/4" dia Brass Threaded ValvesEach17039.2 7039.2
431a-v1-1/2" dia Brass Threaded ValvesEach49930 39720
432a-vi2" dia Brass Threaded ValvesEach114500.8 14500.8
43323 / 45Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic     
434a-ii3/4 inches Each21896 3792
43519 / 12 page 118Providing and fixing brass ball float valve:     
436v4.0 cm (1½") diaEach11934 1934
437**SOIL, WASTE AND VENT PIPES & FITTINGS**      
43819 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
439iii50mmRft50103.95 5197.5
440iv82mmRft100160.6 16060
441v110mmRft80254.3 20344
442vi160mmRft10493.4 4934
44319 / 49Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge.     
444b-iMulti-Trap 4"Each41436.1 5744.4
445c-iiVent Cowel 3"Each2386.1 772.2
44619 / 12 page 119Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge.     
447(i)4" DiameterEach21254.95 2509.9
44821 / 5Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects:     
449a)with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type.Each317212.95 51638.85
450**STORM DRAINAGE PIPES & FITTINGS**      
45119 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
452v110mmRft65254.3 16529.5
45319 / 13 page 119Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge.     
454(i)4" DiameterEach31284.8 3854.4
455**MISCELLANEOUS**      
45619 / 40Supply and fitting of cast iron manhole cover square with frame, etc. complete     
457iii)60cm x 60cm(24"x24") Each26089.85 12179.7
458**NON-SCHEDULED ITEMS**      
459 **GENERAL NOTE **     
460 Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer.     
461**SANITARY FIXTURES AND FITTINGS**      
462NS-01CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects.Each22170 4340
463NS-02Electric water coolers of 40Gallons capacity, minimum two taps, including Tee stop cock on inlet, and all other accessories for complete installation.Each.1121000 121000
464NS-03Triple water filter (10") including inlet and outlet connections, power supply, and all accessories for complete installationEach.132450 32450
465**WATER SUPPLY PIPES AND FITTINGS**      
466 G.I. water pipes conforming to BS-1387, Medium Grade, I/c all fittings, wraping polythene tape, giving anticorrosion treatment, applying protective painting, clamps, hangers & supports, making holes in concrete or masonry and then repairing holes, flushing, disinfecting, testing and commissioning etc. of approved make, of the following diameters,complete in all respects.     
467NS-043/4 inchRft20515 10300
468NS-051 inchRft10755 7550
469NS-061-1/4 inchesRft10825 8250
470NS-071-1/2 inchesRft100950 95000
471NS-082 inchesRft101270 12700
472**MISCELLANEOUS**      
473NS-093/4" diameter Galvanised MS ladder rungs for water tanks; each rung of 18" width, 6" projected outside the wall and 6" embeded in RCC on both ends; including all necessary works for complete installation.Each101490 14900
474NS-10Dia 2" u-turned G.I. vent pipes, pudddle plate, with insect proof mesh at open end etc., complete in all respects.Job17545 7545
475**PLUMBING WORKS**      
476**SWIMMING POOL**      
477**SANITARY FIXTURES AND FITTINGS**      
47819 / 3Providing and fitting imported floor mounted Europeon coupled set of Water Closet (WC) and flushing Cistern of PORTA/ Marachi brand (full size) manufacturer i/c the cost of CP/rubber connection, thimble, seat cover and rawal bolts complete in all respects as approved and directed by the Engineer Incharge.     
479BOne Piece     
480iii.PORTA HD 102N Toilet Cito with Hydraulic Seat CoverEach159851.1 59851.1
48119 / 5Providing and fitting white glazed earthen ware water closet, squartter type, with separate foot rest.Each18761.75 8761.75
48219 / 13 / iProviding and fitting plastic made low down flushing cistern 13.63 litre (3 gallons) capacity, including bracket set, copper connection, etc. complete , whiteEach15803.2 5803.2
48319/49Providing, fixing, testing and commissioning of μ-PVC (Unplasticized polyvinyl Chloride ) Nikasi/ waste pipe Fittings make of Dadex /Popular/Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge.     
484a)P-Trap      
485 (i) 4" diaEach1960.2 960.2
48619 / 4 / ii page 118Providing and fixing, flushing bend of PVC , 4cm (1-1/2")Each1394.65 394.65
48719 / 7Providing and fitting glazed earthen ware wash hand basin/vanity 56x40 cm (22"x16") including bracket set, waste pipe and waste coupling, etc.     
488(v)Under Counter Vanity BasinEach513047.55 65237.75
48919 / 16Providing and fixing, chromium plated soap dish.Each5981.6 4908
49019 / 9 / ii page 119Supply and fixing of Soap Dispensor including all other cost of required fittings & required accessories complete in all respect as approved & directed by the Engineer incharge.: Stainless steelEach24229.4 8458.8
49119 / 18Providing and fixing, chromium plated toilet paper holder.Each11271.45 1271.45
49219 / 19 / iProviding and fixing, chromium plated towel rail, 60 cm (24") long, and 2 cm (¾") diaEach21337.2 2674.4
49319 / 20Providing and fixing looking glass 55x40 cm (22"x16") size and minimum 5 mm thick, first quality.Each51546.2 7731
49419 / 27/ iiProviding and fixing chromium plated bib cock 1.5cm (1/2")Each21588 3176
49519 / 28Providing and fixing chromium plated Tee stop cock 15mm (1/2")Each122068 24816
49619 / 52Providing and fixing CP bath Room Set made of Sonex / Master / Faisal comprising of 3-No Tee stop cocks, lever type Basin Mixer, double Bib Cock, open wall shower, Muslim shower, waste coupling and bottle trap etc. complete in all respect as approved and directed by the Engineer incharge     
497iiLever Type Basin MixerEach56707 33535
498iiiDouble Bib CockEach21907 3814
499ivOpen Type Wall ShowerEach218707 37414
500vMuslim showerEach22387 4774
501viIBottle TrapEach51487 7435
50219 / 7 / ii page 118Providing and fixing 1.5 cm (½") dia connection, including check nuts, etc, (copper connection) Each12712.8 8553.6
50319 / 56 page 117Supply & Installation of Duel (Electric and Gas Water Heaters) with factory-installed pressure relief valve, adjustable water temperature control thermostate, Copper connections for specific capacity having leaving waterr temprature 140 deg F & working pressure 15 PSI, Ambasador/Canon or approved manufacturer i/c cost of all accessories to complete the job as per specifications and standards & making connection, complete in all respect as approved and directed by Engineer Incharge.     
504ii55 GallonsEach183161.5 83161.5
505**WATER SUPPLY PIPES AND FITTINGS**      
50623 / 33 / bProviding, laying, testing and commissioning of POLYPROPYLENE RANDOM COPOLYMER ( PPRC ) water supply pipe (Dadex / Popular / Beta or equivalent ) with specified pressure rating PN ( PRESSURE NOMINAL ) and conforming to DIN 8077 - 8078 code i/c cost of solvent, specials, making jharries complete in all respect as approved and directed by Engineer Incharge. ( Internal / External Diameters mentioned ). PN20     
507ii25mm diaRft10099.7 9970
508iii32mm diaRft60158.25 9495
509iv40mm diaRft20241.75 4835
510v50mm diaRft50347.1 17355
511vi63mm diaRft10541.3 5413
51223 / 42Providing and fixing heavy duty Gate valve of specified diameter and material for pressure rating PN-16 mde of Crane (USA), Hatersly (UK) or Scon (Pakistan) or approved equivalent manufacturer, i/c the cost of all accessories flanges, nut/bolt and gaskit where required complete in all respect as approved and directed by the Engineer Incharge.     
513a-ii3/4" dia Brass Threaded ValvesEach23510 7020
514a-iii1" dia Brass Threaded ValvesEach25025.6 10051.2
515a-iv1-1/4" dia Brass Threaded ValvesEach17039.2 7039.2
516a-v1-1/2" dia Brass Threaded ValvesEach19930 9930
517a-vi2" dia Brass Threaded ValvesEach114500.8 14500.8
51823 / 45Supply & installation of heavy duty Brass PN-16 air Vents of specified size provided at the highest points (Pipe Risers) to expel air as approved and directed by the Engineer Incharge, Automatic     
519a-ii3/4 inches Each21896 3792
520**SOIL, WASTE AND VENT PIPES & FITTINGS**      
52119 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
522iii50mmRft50103.95 5197.5
523iv82mmRft100160.6 16060
524v110mmRft50254.3 12715
525vi160mmRft10493.4 4934
52619 / 49Providing, fixing, testing and commissioning of µ-PVC (Unplasticized polyvinyl Chloride ) Nikasi / waste pipe Fittings make of Dadex / Popular / Beta or approved equivalent manufacturer, conforming to BS 4514 / BS 5255 including the cost of Solvents complete in all respect as approved and directed by the Engineer Incharge.     
527b-iMulti-Trap 4"Each21436.1 2872.2
528c-iiVent Cowel 3"Each2386.1 772.2
52919 / 12 page 119Providing and Fixing of SS 304 Floor Drain, complete in all respect as approved and directed by Engineer Incharge.     
530(i)4" DiameterEach61254.95 7529.7
53121 / 5Constructing gully grating chamber, 12"x12", ( 300x300 mm) complete in all respects:     
532a)with C.I. gully trap, weighing 81 lbs. (36.75 Kg.) frame hinged safety type.Each217212.95 34425.9
533**STORM DRAINAGE PIPES & FITTINGS**      
53419 / 47Providing, fixing, testing and commissioning of (Unplasticized Polyvinyl Chloride Nikasi /SWV pipe, Dadex /Popular /Beta or approved equivalent manufacturer ,plain/Bell Ended/ ZJoints conforming to BS4514/ BS5255- EN1329 including the cost of specials and Solvents complete in all respects ,as per drawings & specifications and /or as approved and directed by the Engineer Incharge.     
535v110mmRft65254.3 16529.5
53619 / 13 page 119Providing and Fixing of SS 304 Roof / scupper Drain, complete in all respect as approved and directed by Engineer Incharge.     
537(i)4" DiameterEach31284.8 3854.4
538**MISCELLANEOUS**      
53919 / 40Supply and fitting of cast iron manhole cover square with frame, etc. complete     
540iii)60cm x 60cm(24"x24") Each16089.85 6089.85
541**NON-SCHEDULED ITEMS**      
542 **GENERAL NOTE **     
543 Supply, installation, testing and commissioning of the following items of work, including all labour, tools, plant, accessories, etc. required for completion of each item as per drawings, specifications and as approved by the Engineer.     
544**SANITARY FIXTURES AND FITTINGS**      
545NS-01CP Small hook of any size and shape, of approved make, complete with plugs and screws etc., fixed to concrete, brick stone or wood work, complete in all respects.Each102170 21700
546NS-02Electric water coolers of 40Gallons capacity, minimum two taps, including Tee stop cock on inlet, and all other accessories for complete installation.Each.1121000 121000
547NS-03Triple water filter (10") including inlet and outlet connections, power supply, and all accessories for complete installationEach.132450 32450
548**SOIL, WASTE AND VENT PIPES & FITTINGS**      
549 G.I. water pipes conforming to BS-1387, Medium Grade, I/c all fittings, wraping polythene tape, giving anticorrosion treatment, applying protective painting, clamps, hangers & supports, making holes in concrete or masonry and then repairing holes, flushing, disinfecting, testing and commissioning etc. of approved make, of the following diameters,complete in all respects.     
550NS-042 inchesRft501270 63500
551 uPVC floor Cleanout of the following diameter, including screw type Stainless Steel/CP top tile access plug, transition pipe, breaking concrete or masonry work & then making it good, etc. complete in all respects.     
552NS-063 inchesEach27765 15530
553NS-074 inchesEach18635 8635
554**MISCELLANEOUS**      
555NS-073/4" diameter Galvanised MS ladder rungs for water tanks; each rung of 18" width, 6" projected outside the wall and 6" embeded in RCC on both ends; including all necessary works for complete installation.Each51490 7450
556**SWIMMING POOL EQUIPMENT**      
557NS-09Swimming pool related all plumbing works including all equipment, pumps, filters,heater, valves,skimmers, piping, fittings, nozzles, drains etc for a tentative pool size as 20'x40'x5' (30,000gallons) and all other works complete.Job13600000 3600000
558**RECEPTION/BILLIARD/TABLE-TENNIS**      
559**ELECTRICAL WORKS**      
560**Conduits & Pipes**      
56146105Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials.     
562ii20 mm i/dRft.4000119.35 477400
563iii25 mm i/dRft.4000138.95 555800
564vi)50 mm i/dRft.500238.15 119075
565vii)80 mm i/dRft.250299.65 74912.5
566viii)100 mm i/dRft.800377.65 302120
56724-105P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge     
568**a)** One way Gange Switch (Small)     
569(i) 01 Gange Each3463.2 1389.6
570(ii) 02 Gange Each5704.4 3522
571(iii)Three pin Light Plug 10/13 AmpEach22754.45 16597.9
572(iv)Telephone / TV/Datacable socketEach10662.45 6624.5
573(v) Fan DimmerEach1740.6 740.6
574(vi)Bell pushEach1598.2 598.2
575(vii) Three Pin Power Plug 15-32 AmpEach8924.55 7396.4
576**b)** One way Gange Switch (Large)     
577(i) 04 Gange Each4981.25 3925
578(ii)05 Gange Each41151.35 4605.4
579(iii) 06 Gange Each41405.85 5623.4
580**C)**Two way Gange Switch Small     
581(i) 01 Gange One Way/ Two WayEach3499.9 1499.7
582**Wiring**      
58324-8Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
584c)450/750 volts, PVC insulated:     
585ii)1.5 mm sq (3/0.029")Per Rft.700042.4 296800
586iii)2.5 mm sq (7/0.029")Per Rft.350062 217000
587iv)4 mm sq (7/0.036")Per Rft.300081.85 245550
588**LT Cables**      
58924-10Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):-     
590i)4 mm sq (7/0.036")Per Rft.5074.65 3732.5
591ii)6 mm sq (7/0.044")Per Rft.10100.45 1004.5
592iii)10 mm sq (7/0.052")Per Rft.250155.7 38925
593iv)16 mm sq (7/0.064")Per Rft.50234.3 11715
59424-11Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):-     
595c)PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:-     
596iv)4 mm sq (7/0.036")Per Rft.250268.75 67187.5
597v)6 mm sq (7/0.044")Per Rft.20381.4 7628
598vi)10 mm sq (7/0.052")Per Rft.150605.85 90877.5
599vii)16 mm sq (7/0.064")Per Rft.150926.05 138907.5
600viii)25 mm sq (19/0.052")Per Rft.201426.2 28524
601ix)35 mm sq (19/0.064")Per Rft.1501919.9 287985
602**Fans and Exhaust Fans**      
60324-102Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge.     
604a)-iPlastic body - 10" diaEach25235.5 10471
605a)-iiPlastic body - 12" diaEach15685.5 5685.5
606**b) ****Steel body**     
607i12" sweepEach15516.75 5516.75
608ii18" sweepEach 6641.75  
60924-103Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
610ii)24" Sweep diaEach410703 42812
61124-104Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
612(iii)56" diaEach110180.2 10180.2
613**Lightning Protection System**      
61424-111Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing)P.Job221210.95 42421.9
61524-113Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System     
616viii) 70 mm² CU bare conductorPer Rft200850.45 170090
617**CCTV**      
61824-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge.      
619a)UTP (Unshielded Twisted pair)     
620(i)CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet systemPer Rft120049.2 59040
62124-126Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.     
622ii)16-ChannelEach1116388.7 116388.7
62324-127Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge     
624iii)10 TBEach169360 69360
62524-128Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2 x 1Gigabit SFP ports with 2 x 1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP nooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/ Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge.Each1364102.5 364102.5
62624-132Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
627b4 Mega PixeL     
628(i)Fixed Bullet TypeEach171535 71535
629(ii)Fixed Dome typeEach582785 413925
63024-139Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge     
631ii15U size (600x550x770 mmEach159379.95 59379.95
63224-138Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge.Each1641053.15 641053.15
633**DATA NETWORK & WIFI SYSTEM**      
634**Data Cabling System**      
63524-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge.     
636a-ii)UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher)P.Rft150069.6 104400
63724-119Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge.     
638i)1 meter Patch CordEach81074.4 8595.2
639ii)3 meter Patch CordEach81309.6 10476.8
64024-124Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.Each14108.8 4108.8
64124-125Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge.     
642ii)CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit)Each135405 35405
64324-141Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project.     
644i)Single I/OEach81678.15 13425.2
645ii)Double I/OEach 2626.5  
64624-142Supply, Installation and commissioning of Core Switches with interface : 10 GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
647i) 24 PortsEach1125582.25 125582.25
64814324-Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
649 24 PortsEach191902 91902
65024-144Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge.     
651a-(ii) 06 CorePER RFT250596.4 149100
65224-145Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge     
653a) Multimode (MM) Ports     
654(ii) 12 PortsEach164560.4 64560.4
65524-160Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge.     
656 b) Column Type Speaker     
657(iv) 60 WattEach480081.25 320325
65824-162Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge.     
659vi) 480 WattEach1468983.65 468983.65
66024-165Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge     
661i)Cordless Microphone with TransmitterEach1151462.9 151462.9
66224-166Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer InchargeEach1116294.25 116294.25
66324-15Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
664a)-iFlexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029")Per Rft500128.45 64225
66524-85Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge     
666a) Single Pole     
667(iii) 6-63 Amp (10 KA) Each401459.05 58362
668b) Double Pole     
669 iii) 6-63 Amp (10 KA)Each15621.55 5621.55
67024-86Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge     
671a) Triple Pole     
672(iii) 15-100 Amp(18 KA)Each1212172.95 146075.4
673viii) 125-150 Amp(36 KA)Each326516.7 79550.1
67424-90(Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately).      
675(a) 6" deep     
676(i) 20~60A P.CFT302463.7 73911
677ii) 75~100AP.CFT202604.4 52088
678(b) 12" deep     
679(i) 125~150AP.CFT207011.65 140233
68024-91P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately).     
6811 LT Switchboards     
682a)(i)2.50 Ft deep 250~600A P. cft 204772.65 95453
68324-94Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge     
684i) Selector SwitchEach11228.8 1228.8
685(ii) Current Transformer Coil (Make: Metelx/Fico)Each62134.3 12805.8
686(iii) Digital Voltmeter (0-600 Volt)Each61012.8 6076.8
687(iv) Digital Ammeter (0-9999 Amp)Each61228.8 7372.8
688(v) LED Phase IndicatorEach9622.8 5605.2
689(vi) Push Button ON/OFF (Make: Schneider/Himal/Eqv.)Each6631.15 3786.9
690vii) Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB)Each65373.8 32242.8
691viii) Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB)Each91375.8 12382.2
692ix) Surge SuppressorsEach61060.8 6364.8
693x) Auto/Manual Switch 3-Steps (Make: GGT/Camsco)Each12257.8 2257.8
694xi) Exhaust Fan with Louvers (Make: Imported/PlastimEach33832.8 11498.4
695xii) Temperature Regulator 0~60CEach32134.3 6402.9
696xiii)(Power CapacitorsEach    
697a) 12.5 KVAREach116852.8 16852.8
698b) 25 KVAREach125852.8 25852.8
699 Magnetic Contactor     
700(a) 25 A (AC 3) for 12.5 KVAREach310048.8 30146.4
701b) 40 A (AC 3) for 25 KVAREach314332.8 42998.4
702(xvii)Power Factor Controller      
703a) 6 StepsEach155252.8 55252.8
704**Non - Schedule Items**      
705**Light Fixtures**      
706 Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. **Note:** Refer light fixtures drawings/Schedule for complete light fixtures details.     
707NS-0140 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects.No.29500 19000
708NS-02(16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects.No.62500 15000
710NS-0315-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.603500 210000
711NS-047-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.51950 9750
712NS-05Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better ratedNo.86500 52000
713NS-06LED EXIT LIGHT 8/10 WNo.59500 47500
714 Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding, fittings insulation,tape wraping etc, insulation, refrigerant charge thermostate, control between indoor and outdoor units power wiring, conduiting, dura duct / channel mounting brackets and accessories complete in all respect.      
715NS-07Split Air- Conditioner 1.5 tonJob4350000 1400000
716NS-08Floor standing type Air- Conditioner 4 tonJob41200000 4800000
717**CAFE/CIGAR ROOM (GF + FF)**      
718**ELECTRICAL WORKS**      
719**Conduits & Pipes**      
72024-3Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials.     
721ii20 mm i/dRft.8000119.35 954800
722iii25 mm i/dRft.10000138.95 1389500
723vi)50 mm i/dRft.2000238.15 476300
724vii)80 mm i/dRft.500299.65 149825
725viii)100 mm i/dRft.1000377.65 377650
72624-105P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made ofLegrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge     
727a) One way Gange Switch (Small)     
728(i) 01 Gange Each5463.2 2316
729(ii) 02 Gange Each10704.4 7044
730(iii)Three pin Light Plug 10/13 AmpEach50754.45 37722.5
731(iv)Telephone / TV/Datacable socketEach15662.45 9936.75
732(v) Fan DimmerEach1740.6 740.6
733(vi)Bell pushEach1598.2 598.2
734(vii) Three Pin Power Plug 15-32 AmpEach10924.55 9245.5
735b) One way Gange Switch (Large)     
736(i) 04 Gange Each6981.25 5887.5
737(ii)05 Gange Each61151.35 6908.1
738(iii) 06 Gange Each61405.85 8435.1
739C)Two way Gange Switch Small     
740(i) 01 Gange One Way/ Two WayEach4499.9 1999.6
741**WIRING**      
74224-8Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
743c)450/750 volts, PVC insulated:     
744ii)1.5 mm sq (3/0.029")Per Rft.1500042.4 636000
745iii)2.5 mm sq (7/0.029")Per Rft.550062 341000
746iv)4 mm sq (7/0.036")Per Rft.400081.85 327400
747**LT CABLES**      
74824-10Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):-     
749i)4 mm sq (7/0.036")Per Rft.5074.65 3732.5
750ii)6 mm sq (7/0.044")Per Rft.10100.45 1004.5
751iii)10 mm sq (7/0.052")Per Rft.500155.7 77850
752iv)16 mm sq (7/0.064")Per Rft.50234.3 11715
753viii)70 mm sq (19/0.083")Per Rft.250917.85 229462.5
75424-11Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):-     
755c)PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:-     
756iv)4 mm sq (7/0.036")Per Rft.500268.75 134375
757v)6 mm sq (7/0.044")Per Rft.250381.4 95350
758vi)10 mm sq (7/0.052")Per Rft.300605.85 181755
759vii)16 mm sq (7/0.064")Per Rft.300926.05 277815
760viii)25 mm sq (19/0.052")Per Rft.501426.2 71310
761ix)35 mm sq (19/0.064")Per Rft.3001919.9 575970
762**Fans and Exhaust Fans**      
76324-102Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge.     
764a)-iPlastic body - 10" diaEach35235.5 15706.5
765a)-iiPlastic body - 12" diaEach25685.5 11371
766 b) Steel body      
767i12" sweepEach15516.75 5516.75
768ii18" sweepEach16641.75 6641.75
76924-103Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
770ii)24" Sweep diaEach1010703 107030
77124-104Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
772(iii)56" diaEach110180.2 10180.2
773**Lightning Protection System**      
77424-111Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing)P.Job521210.95 106054.75
77524-113Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System     
776viii) 70 mm² CU bare conductorPer Rft225850.45 191351.25
777**CCTV**      
77824-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge.      
779a)UTP (Unshielded Twisted pair)     
780(i) CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet systemPer Rft300049.2 147600
78124-126Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.     
782ii)16-ChannelEach1116388.7 116388.7
78324-127Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge     
784iii)10 TBEach169360 69360
78524-128Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge.Each1364102.5 364102.5
78624-132Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
787b4 Mega PixeL     
788(i)Fixed Bullet TypeEach271535 143070
789(ii)Fixed Dome typeEach682785 496710
79024-139Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge     
791ii15U size (600x550x770 mmEach159379.95 59379.95
79224-138Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge.Each1641053.15 641053.15
793 ** DATA NETWORK & WIFI SYSTEM**      
794 ** Data Cabling System**     
79524-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge.     
796a-ii)UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher)P.Rft250069.6 174000
79724-119Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge.     
798i)1 meter Patch CordEach101074.4 10744
799ii)3 meter Patch CordEach101309.6 13096
80024-124Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.Each14108.8 4108.8
80124-125Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge.     
802ii)CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit)Each135405 35405
80324-141Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project.     
804i)Single I/OEach101678.15 16781.5
80524-142Supply, Installation and commissioning of Core Switches with interface : 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
806i) 24 PortsEach1125582.25 125582.25
80724-143Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
808 24 PortsEach191902 91902
80924-144Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge.     
810a-(ii) 06 CorePER RFT500596.4 298200
81124-145Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge     
812a) Multimode (MM) Ports     
813(ii) 12 PortsEach164560.4 64560.4
81424-160Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge.     
815 b) Column Type Speaker     
816(iv) 60 WattEach880081.25 640650
81724-162Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge.     
818vi) 480 WattEach1468983.65 468983.65
81924-165Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge     
820i)Cordless Microphone with TransmitterEach1151462.9 151462.9
82124-166Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer InchargeEach1116294.25 116294.25
82224-15Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
823a)i Flexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029")Per Rft1000128.45 128450
82424-93P/F PFI PLANT (Power Factor Improvement Plant) comprising ofcomponents of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors,Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge.      
825i) 62.5 KVArEach1269555 269555
82624-85Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge     
827a) Single Pole     
828(iii) 6-63 Amp (10 KA) Each601459.05 87543
829b) Double Pole     
830 iii) 6-63 Amp (10 KA)Each25621.55 11243.1
83124-86Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge     
832a) Triple Pole     
833(iii) 15-100 Amp(18 KA)Each2412172.95 292150.8
834viii) 125-150 Amp(36 KA)Each526516.7 132583.5
83524-90(Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/Fwall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately).      
836(a)6" deep     
837(i) 20~60A P.CFT502463.7 123185
838ii)75~100AP.CFT202604.4 52088
839(b)12" deep     
840(i) 125~150AP.CFT207011.65 140233
841ii)160~200AP.CFT206188.55 123771
84224-91P/F floor mounted Electric Panel board of required depth and size,fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately).     
8431 LT Switchboards     
844a)(i) 2.50 Ft deep 250~600A P. cft 304772.65 143179.5
84524-94Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge     
846i)Selector SwitchEach11228.8 1228.8
847(ii)Current Transformer Coil (Make: Metelx/Fico)Each62134.3 12805.8
848(iii)Digital Voltmeter (0-600 Volt)Each61012.8 6076.8
849(iv)Digital Ammeter (0-9999 Amp)Each61228.8 7372.8
850(v)LED Phase IndicatorEach18622.8 11210.4
851(vi) Push Button ON/OFF (Make: Schneider/Himal/Eqv.)Each6631.15 3786.9
852vii)Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB)Each65373.8 32242.8
853viii) Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB)Each181375.8 24764.4
854ix)Surge SuppressorsEach61060.8 6364.8
855x) Auto/Manual Switch 3-Steps (Make: GGT/Camsco)Each12257.8 2257.8
856xi)Exhaust Fan with Louvers (Make: Imported/PlastimEach33832.8 11498.4
857xii)Temperature Regulator 0~60CEach32134.3 6402.9
858xiii)(Power CapacitorsEach    
859a) 12.5 KVAREach116852.8 16852.8
860b) 25 KVAREach125852.8 25852.8
861 Magnetic Contactor     
862(a) 25 A (AC 3) for 12.5 KVAREach310048.8 30146.4
863b) 40 A (AC 3) for 25 KVAREach314332.8 42998.4
864(xvii)Power Factor Controller      
865a) 6 StepsEach155252.8 55252.8
866**Non - Schedule Items**      
867** Light Fixtures**      
868 Ref. Specs Sec. 8001, 8150     
869 Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details.     
870NS-0140 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects.No.59500 47500
871NS-02(16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects.No.102500 25000
872NS-0315-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.1003500 350000
873NS-047-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.51950 9750
874NS-05Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better ratedNo.206500 130000
875NS-06LED EXIT LIGHT 8/10 WNo.109500 95000
876 Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation, condensate drain piping including Venture Cladding, fittings insulation, tape wraping etc, insulation, refrigerant charge thermostate, control between indoor and outdoor units power wiring, conduiting, dura duct / channel mounting brackets and accessories complete in all respect.      
877NS-07Split Air- Conditioner 1.5 tonJob2350000 700000
878NS-08Cassette ceiling type Air- Conditioner 4 tonJob41500000 6000000
879NS-09Floor standing type Air- Conditioner 4 tonJob101200000 12000000
880**SWIMMING POOL & GYM**      
881**ELECTRICAL WORKS**      
882**Conduits & Pipes**      
88324-3Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials.     
884ii20 mm i/dRft.15000119.35 1790250
885iii25 mm i/dRft.16000138.95 2223200
886vi)50 mm i/dRft.2000238.15 476300
887vii)80 mm i/dRft.500299.65 149825
888viii)100 mm i/dRft.1000377.65 377650
88924-105P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenide or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge     
890a) One way Gange Switch (Small)     
891(i) 01 Gange Each7463.2 3242.4
892(ii) 02 Gange Each12704.4 8452.8
893(iii)Three pin Light Plug 10/13 AmpEach50754.45 37722.5
894(iv)Telephone / TV/Datacable socketEach15662.45 9936.75
895(v) Fan DimmerEach1740.6 740.6
896(vi)Bell pushEach1598.2 598.2
897(vii) Three Pin Power Plug 15-32 AmpEach20924.55 18491
898b) One way Gange Switch (Large)     
899(i) 04 Gange Each8981.25 7850
900(ii)05 Gange Each81151.35 9210.8
901(iii) 06 Gange Each81405.85 11246.8
902C)Two way Gange Switch Small     
903(i) 01 Gange One Way/ Two WayEach6499.9 2999.4
904 Wiring     
90524-8Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
906c)450/750 volts, PVC insulated:     
907ii)1.5 mm sq (3/0.029")Per Rft.1800042.4 763200
908iii)2.5 mm sq (7/0.029")Per Rft.580062 359600
909iv)4 mm sq (7/0.036")Per Rft.500081.85 409250
910 LT Cables     
91124-10Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):-     
912i)4 mm sq (7/0.036")Per Rft.5074.65 3732.5
913ii)6 mm sq (7/0.044")Per Rft.10100.45 1004.5
914iii)10 mm sq (7/0.052")Per Rft.1000155.7 155700
915iv)16 mm sq (7/0.064")Per Rft.100234.3 23430
916vii)70 mm sq (19/0.083")Per Rft.500917.85 458925
91724-11Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):-     
918c)PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:-     
919iv)4 mm sq (7/0.036")Per Rft.600268.75 161250
920v)6 mm sq (7/0.044")Per Rft.250381.4 95350
921vi)10 mm sq (7/0.052")Per Rft.500605.85 302925
922vii)16 mm sq (7/0.064")Per Rft.300926.05 277815
923viii)25 mm sq (19/0.052")Per Rft.5001426.2 713100
924ix)35 mm sq (19/0.064")Per Rft.6001919.9 1151940
925 Fans and Exhaust Fans     
92624-102Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge.     
927a)-iPlastic body - 10" diaEach65235.5 31413
928a)-iiPlastic body - 12" diaEach45685.5 22742
929 b) Steel body      
930i12" sweepEach15516.75 5516.75
931ii18" sweepEach16641.75 6641.75
93224-103Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
933ii)24" Sweep diaEach1510703 160545
93424-104Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
935(iii)56" diaEach110180.2 10180.2
936 Lightning Protection System     
93724-111Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing)P.Job521210.95 106054.75
93824-113Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System     
939viii) 70 mm² CU bare conductorPer Rft300850.45 255135
940**CCTV**      
94124-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge.      
942a)UTP (Unshielded Twisted pair)     
943(i) CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet systemPer Rft500049.2 246000
94424-126Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.     
945iii)32-ChannelEach1131353.5 131353.5
94624-127Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge     
947iii)10 TBEach269360 138720
94824-128Supply, Installation and Connection of L2 Access Switches 24xEthernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge.Each2364102.5 728205
94924-131Supply, Installation and Connection of Fiber Optic SC-LC Patch CordsOS2 or OM3 of Specified Length from PoE Switch to ODF Point, UL Listed, Made of Schneider / Norden ,Pollo Australia or equivalent as approved and directed by Engineer InchargeP.Rft2501922 480500
95024-132Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
951b4 Mega PixeL     
952(i)Fixed Bullet TypeEach471535 286140
953(ii)Fixed Dome typeEach1282785 993420
95424-139Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge     
955ii15U size (600x550x770 mmEach259379.95 118759.9
95624-138Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge.Each1641053.15 641053.15
957**DATA NETWORK & WIFI SYSTEM**      
958**Data Cabling System**      
95924-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge.     
960a-ii)UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher)P.Rft500069.6 348000
96124-119Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge.     
962i)1 meter Patch CordEach151074.4 16116
963ii)3 meter Patch CordEach151309.6 19644
96424-124Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.Each24108.8 8217.6
96524-125Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge.     
966ii)CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit)Each235405 70810
96724-141Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project.     
968i)Single I/OEach151678.15 25172.25
96924-142Supply, Installation and commissioning of Core Switches with interface: 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP), Bandwidth: Tbps or higher with Quad-core processor or higher, MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
970i) 24 PortsEach2125582.25 251164.5
97124-143Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity: 90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei/ H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
972 24 PortsEach191902 91902
97324-144Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed, in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider /Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge.     
974a(ii) 06 CorePER RFT1000596.4 596400
97524-145Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge     
976a) Multimode (MM) Ports     
977(ii) 12 PortsEach164560.4 64560.4
97824-160Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge.     
979 b) Column Type Speaker     
980(iv) 60 WattEach880081.25 640650
98124-162Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge.     
982vi)480 WattEach1468983.65 468983.65
98324-165Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge     
984i)Cordless Microphone with TransmitterEach1151462.9 151462.9
98524-166Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer InchargeEach1116294.25 116294.25
98624-15Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
987a)-iFlexible 3 core, 600/1000 volt non armoured cable:- 1.5sqm (3/.029")Per Rft1000128.45 128450
98824-93P/F PFI PLANT (Power Factor Improvement Plant) comprising of components of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors, Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge.      
989i) 62.5KVArEach1269555 269555
99024-85Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge     
991a) Single Pole     
992(iii) 6-63 Amp (10 KA) Each1001459.05 145905
993b) Double Pole     
994 iii) 6-63 Amp (10 KA)Each25621.55 11243.1
99524-86Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge     
996a) Triple Pole     
997(iii) 15-100 Amp(18 KA)Each4812172.95 584301.6
998viii) 125-150 Amp(36 KA)Each1026516.7 265167
999(ix) 200-250 Amp(36 KA)Each647329.2 283975.2
1000x) 300-630 Amp(36 KA)Each293383.35 186766.7
100124-90(Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector switch, Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately).      
1002(a) 6" deep     
1003(i) 20~60A P.CFT1002463.7 246370
1004ii) 75~100AP.CFT502604.4 130220
1005(b) 12" deep     
1006(i) 125~150AP.CFT407011.65 280466
1007ii) 160~200AP.CFT406188.55 247542
100824-91P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately).     
10091 LT Switchboards     
1010a)(i) 2.50 Ft deep 250~600A P. cft 504772.65 238632.5
101124-94Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge     
1012i) Selector SwitchEach21228.8 2457.6
1013(ii) Current Transformer Coil (Make: Metelx/Fico)Each122134.3 25611.6
1014(iii) Digital Voltmeter (0-600 Volt)Each121012.8 12153.6
1015(iv) Digital Ammeter (0-9999 Amp)Each121228.8 14745.6
1016(v) LED Phase IndicatorEach36622.8 22420.8
1017(vi) Push Button ON/OFF (Make: Schneider/Himal/Eqv.)Each12631.15 7573.8
1018vii) Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB)Each125373.8 64485.6
1019viii) Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB)Each361375.8 49528.8
1020ix) Surge SuppressorsEach121060.8 12729.6
1021x) Auto/Manual Switch 3-Steps (Make: GGT/Camsco)Each22257.8 4515.6
1022xi) Exhaust Fan with Louvers (Make: Imported/PlastimEach63832.8 22996.8
1023xii) Temperature Regulator 0~60CEach62134.3 12805.8
1024xiii)(Power CapacitorsEach    
1025a) 12.5 KVAREach216852.8 33705.6
1026b) 25 KVAREach225852.8 51705.6
1027c) 50 KVAREach166052.8 66052.8
1028 Magnetic Contactor     
1029(a) 25 A (AC 3) for 12.5 KVAREach610048.8 60292.8
1030b) 40 A (AC 3) for 25 KVAREach614332.8 85996.8
1031(xvii)Power Factor Controller      
1032a) 6 StepsEach255252.8 110505.6
1033**Non -Schedule Items**      
1034**Light Fixtures**      
1035 Ref. Specs Sec. 8001, 8150     
1036 Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders, SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details.     
1037NS-0140 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects.No.109500 95000
1038NS-02(16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects.No.202500 50000
1039NS-0315-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.3003500 1050000
1040NS-047-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.51950 9750
1041NS-05Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better ratedNo.206500 130000
1042NS-06LED EXIT LIGHT 8/10 WNo.209500 190000
1043NS-0720 watt under water light ip 67 No.2045000 900000
1044 Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding , fittings insulation,tape wraping etc , insulation,refrigerant charge thermostate ,control between indoor and outdoor units power wiring , conduiting , dura duct / channel mounting brackets and accessories complete in all respect.      
1045NS-08Split Air- Conditioner 1.5 tonJob4350000 1400000
1046NS-09Cassette ceiling type Air- Conditioner 4 tonJob41500000 6000000
1047NS-10Floor standing type Air- Conditioner 4 tonJob151200000 18000000
1048**BADMINTON HAL**      
1049**ELECTRICAL WORKS**      
1050**Conduits & Pipes**      
105124-3Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials.     
1052ii20 mm i/dRft.3800119.35 453530
1053iii25 mm i/dRft.3700138.95 514115
1054vi)50 mm i/dRft.500238.15 119075
1055vii)80 mm i/dRft.250299.65 74912.5
1056viii)100 mm i/dRft.800377.65 302120
105724-105P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenider or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge     
1058a) One way Gange Switch (Small)     
1059(i) 01 Gange Each3463.2 1389.6
1060(ii) 02 Gange Each5704.4 3522
1061(iii)Three pin Light Plug 10/13 AmpEach22754.45 16597.9
1062(iv)Telephone / TV/Datacable socketEach10662.45 6624.5
1063(v)Fan DimmerEach1740.6 740.6
1064(vi)Bell pushEach1598.2 598.2
1065(vii)Three Pin Power Plug 15-32 AmpEach8924.55 7396.4
1066b)One way Gange Switch (Large)     
1067(i) 04 Gange Each4981.25 3925
1068(ii)05 Gange Each41151.35 4605.4
1069(iii)06 Gange Each41405.85 5623.4
1070C)Two way Gange Switch Small     
1071(i)01 Gange One Way/ Two WayEach3499.9 1499.7
1072**Wiring**      
107324-8Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
1074c)450/750 volts, PVC insulated:     
1075ii)1.5 mm sq (3/0.029")Per Rft.650042.4 275600
1076iii)2.5 mm sq (7/0.029")Per Rft.330062 204600
1077iv)4 mm sq (7/0.036")Per Rft.280081.85 229180
1078**LT Cables**      
107924-10Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):-     
1080i)4 mm sq (7/0.036")Per Rft.5074.65 3732.5
1081ii)6 mm sq (7/0.044")Per Rft.10100.45 1004.5
1082iii)10 mm sq (7/0.052")Per Rft.250155.7 38925
1083iv)16 mm sq (7/0.064")Per Rft.50234.3 11715
108424-11Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):-     
1085c)PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:-     
1086iv)4 mm sq (7/0.036")Per Rft.250268.75 67187.5
1087v)6 mm sq (7/0.044")Per Rft.20381.4 7628
1088vi)10 mm sq (7/0.052")Per Rft.150605.85 90877.5
1089vii)16 mm sq (7/0.064")Per Rft.150926.05 138907.5
1090viii)25 mm sq (19/0.052")Per Rft.201426.2 28524
1091ix)35 mm sq (19/0.064")Per Rft.1501919.9 287985
1092 Fans and Exhaust Fans     
109324-102Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge.     
1094a)-iPlastic body - 10" diaEach25235.5 10471
1095a)-iiPlastic body - 12" diaEach15685.5 5685.5
1096 b) Steel body      
1097i12" sweepEach15516.75 5516.75
1098ii18" sweepEach 6641.75  
109924-103Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
1100ii)24" Sweep diaEach410703 42812
110124-104Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
1102(iii)56" diaEach110180.2 10180.2
1103**Lightning Protection System**      
110424-111Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link coppe plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers lugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing)P.Job221210.95 42421.9
110524-113Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System     
1106viii) 70 mm² CU bare conductorPer Rft200850.45 170090
1107**CCTV**      
110824-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge.      
1109a)UTP (Unshielded Twisted pair)     
1110(i)CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet systemPer Rft120049.2 59040
111124-126Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.     
1112ii)16-ChannelEach1116388.7 116388.7
111324-127Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge     
1114iii)10 TBEach169360 69360
111524-128Supply, Installation and Connection of L2 Access Switches 24 x Ethernet 10/100/1000 base-T port, min 2 x 1 Gigabit SFP ports with 2 x 1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge.Each1364102.5 364102.5
111624-132Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
1117b4 Mega PixeL     
1118(i)Fixed Bullet TypeEach171535 71535
1119(ii)Fixed Dome typeEach582785 413925
112024-139Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge     
1121ii15U size (600 x 550 x 770 mm)Each159379.95 59379.95
112224-138Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge.Each1641053.15 641053.15
1123**DATA NETWORK & WIFI SYSTEM**      
1124**Data Cabling System**      
112524-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23AWG UL/ EN listed cable *Conforming to following standards: TIA/EIA568/ISO/IEC11801, in prelaid conduit/ cable tray from including all accessories, Manufacturer/ OEM Authorization, Make: Schneider/ i-connect UK/ 3M Corning USA/ D-Link/ Pollo Australian or equivalent complete in all respect as approved and directed by Engineer Incharge.     
1126a-ii)UTP (Unshielded Twisted pair) CAT-6A (Min.1G/ 10G @ 500MHz or higher)P.Rft150069.6 104400
112724-119Supply, installation and connections of CAT-6A UTP (Unsheilded Twisted Pair), patch cord of specified length, Factory Fabricated and UL Listed with anti Snag Boots-Gold over nickel plated made of Schneider, Pollo Australia or equivalent as approved and directed by Engineer Incharge.     
1128i)1 meter Patch CordEach81074.4 8595.2
1129ii)3 meter Patch CordEach81309.6 10476.8
113024-124Supply and installation of Cable Metal Organizer, 19" Rack mounted with high graded epoxy powder coating and slideable top-UL Listed. Made of Schneider/ i-Connect UK/ 3M Corning :Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.Each14108.8 4108.8
113124-125Supply, Installation and commissioning of 19" Rack Mounted of specified, UTP Patch Panel with specified toolless support & Rear Cable Management, ULlisted, Loaded with UTP of specified Keystone Jack Toolless Support, Made of Schneider/ Norden/ 3M Corning/ D-Link, Pollo Australia or equivalent approved manufacturer and Directed by Engineer Incharge.     
1132ii)CAT-6A (24 Port Patch Panel with Toolless Support 10-Gigabit)Each135405 35405
113324-141Supply, Installation and commissioning of Simple type, Dual Shutter Face Plates having fully populated I/O: Option 1:RJ-11 with RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project Option 2: Two RJ45/8P8C I/Os supporting either Cat6 or Cat6a cables as required by project.     
1134i)Single I/OEach81678.15 13425.2
113524-142Supply, Installation and commissioning of Core Switches with interface : 10GBASE-R(SFP+)/1000 BASE-X(SFP) 4X40 BASE -SR4/LR4 (QSFP) ,Bandwidth: Tbps or higher with Quad-core processor or higher,MAC Table: 96K ,AC Power: 220V+-10%,cooling fans made of RUCKS USA/Cisco USA/Juniper USA, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
1136i) 24 PortsEach1125582.25 125582.25
113724-143Supply, Installation and commissioning of Access Switches Layer 3, with specified 1000 Base-T (RJ-45) Ports (PoE/PoE+) with 4 x 10 G SFP+ with license , Switching capacity 128 Gbps or higher,Packet forwarding capacity :90 Mpps,RAM (DDR3):512 MB, DHCP snooping, ACL, power supply Min.350 Watt AC, made of RUCKS USA/Cisco USA/Juniper USA / Huawei / H3C, Pollo Australia or equivalent as approved and directed by Engineer's Incharge.     
1138 24 PortsEach191902 91902
113924-144Supply, Installation and commissioning of Armored Fiber Optic Cable of specified core and mode, Fiber Optic Connection, UL listed , in prelaid/pipe, cable tray , including all accessories, made of Norden / Schneider / Panduit/Pollo Australia or equivalent Complete in all respect as approved and directed by Engineer Incharge.     
1140a(ii) 06 CorePER RFT250596.4 149100
114124-145Supply, Installation of OFDF (Optical Fiber Distribution Frame) having specified mode ports Loaded with Splicing Tray, with splicing of Pigtails, Fully loaded DUPLEX SC Couplers& Pigtail supplied with Patch Leads (LC SC) or as per site SFP based required cords, UL Listed, Made of Schneider / Norden, Pollo Australia or equivalent or as approved and directed by the Engineer Incharge     
1142a) Multimode (MM) Ports     
1143(ii) 12 PortsEach164560.4 64560.4
114424--160Supply, Installation & Commissioning of recessed/surface mounted Speakers of specified capacity housed in metalic enclosure with builtin 70v/100v transformer , aluminium grill, SPL (Sound Pressure Level) (1W / 1M)= 92dB max 99dB, frequency response 130-13 Khz, EN-54 compliant, Including cost of all accessories and matierlas, complete in all respect made of Ecler Europe/Bosch/ Norden / Honey Well or equivalent as approved and directed by the Engineer Incharge.     
1145 b) Column Type Speaker     
1146(iv) 60 WattEach480081.25 320325
114724-162Supply, Installation and commissioning of Power / Mixer Amplifier of specified wattage, Including cost of all necessary accessories / materials , completein all respectsmadeof Ecler Europe/Bosch/ Norden / Honey Well or Equivalent or as approved and directed by Engineer Incharge.     
1148vi) 480 WattEach1468983.65 468983.65
114924-165Supply, Installation of Microphone of specified quality as per requirement made of : Norden, Bosch, Honeywell. Complete in all respect. as approved and directed by Engineer Incharge     
1150i)Cordless Microphone with TransmitterEach1151462.9 151462.9
115124-166Supplying, Installation of musical source multiformat audio player, including cost of all necessary accessories / materials , complete in all respects. made of Bosch/ Norden / Honey Well or equivalent, as approved and directed by Engineer InchargeEach1116294.25 116294.25
115224-15Supply and erection of PVC insulated, PVC Sheathed flexible copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
1153a)-iFlexible 3 core, 600/1000 volt non armoured cable:- 1.5 sqmm (3/.029")Per Rft500128.45 64225
115424-85Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge     
1155a)Single Pole     
1156(iii)6-63 Amp (10 KA) Each401459.05 58362
1157b)Double Pole     
1158iii) 6-63 Amp (10 KA)Each15621.55 5621.55
115924-86Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge     
1160a) Triple Pole     
1161(iii) 15-100 Amp(18 KA)Each1212172.95 146075.4
1162viii) 125-150 Amp(36 KA)Each326516.7 79550.1
116324-90(Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights,Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter,Digital Ammeter,Volt Selector Switch,Ammeter selector switch,Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately).      
1164(a) 6" deep     
1165(i) 20~60A P.CFT302463.7 73911
1166ii) 75~100AP.CFT202604.4 52088
1167(b) 12" deep     
1168(i) 125~150AP.CFT207011.65 140233
116924-91P/F floor mounted Electric Panel board of required depth and size, fabricarted with 14SWG M.S sheet (Indoor/Outdoor Type),derusting, zinc Phosphated, finish with electro static powder coating in approved colour i/c the cost of capacitor trip unit over current, Lock, Indication lights, Brass glands, Netural & Earth bar, Digital volt meter/ Amp meter, Slector switchs, Current Transformers, Controles, Channels, Copper bus bars of specified capacity ,Door Earthing, complete in all respects as approved and directed by the Engineer Incharge (Breakers will be Paid Separately).     
11701 LT Switchboards     
1171a)(i) 2.50 Ft deep 250~600A P. cft 204772.65 95453
117224-94Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge     
1173i)Selector SwitchEach11228.8 1228.8
1174(ii)Current Transformer Coil (Make: Metelx/Fico)Each62134.3 12805.8
1175(iii)Digital Voltmeter (0-600 Volt)Each61012.8 6076.8
1176(iv)Digital Ammeter (0-9999 Amp)Each61228.8 7372.8
1177(v)LED Phase IndicatorEach9622.8 5605.2
1178(vi) Push Button ON/OFF (Make: Schneider/Himal/Eqv.)Each6631.15 3786.9
1179vii)Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB)Each65373.8 32242.8
1180viii) Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB)Each91375.8 12382.2
1181ix)Surge SuppressorsEach61060.8 6364.8
1182x) Auto/Manual Switch 3-Steps (Make: GGT/Camsco)Each12257.8 2257.8
1183xi)Exhaust Fan with Louvers (Make: Imported/PlastimEach33832.8 11498.4
1184xii)Temperature Regulator 0~60CEach32134.3 6402.9
1185xiii)(Power CapacitorsEach    
1186a) 12.5 KVAREach116852.8 16852.8
1187b) 25 KVAREach125852.8 25852.8
1188 Magnetic Contactor     
1189(a) 25 A (AC 3) for 12.5 KVAREach310048.8 30146.4
1190b) 40 A (AC 3) for 25 KVAREach314332.8 42998.4
1191(xvii)Power Factor Controller      
1192a) 6 StepsEach155252.8 55252.8
1193**Non - Schedule Items**      
1194**Light Fixtures**      
1195 Ref. Specs Sec. 8001, 8150     
1196 Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders, SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details.     
1197NS-0140 watt Surface mounted Damp proof LED Light Fixture with 4400 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, PF=.95 complete in all respects.No.29500 19000
1198NS-02(16-20) Watt Surface mounted LED batten Light Fixture with 2000 lumens min., 30000 Life Hrs. fixed output LED driver, IP20 rated, complete in all respects.No.62500 15000
1199NS-0315-20 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.603500 210000
1200NS-047-10 W Surface/ ceiling Mounted LED downlight with bult in integrated driver and frosted glass diffuser No.51950 9750
1201NS-05Outdoor type LED bulkhead wall light of minimum 1500 lumens light output, IP-55 or better ratedNo.86500 52000
1202NS-06LED EXIT LIGHT 8/10 WNo.59500 47500
1203 Supply & Installation of split/ Cassette type reversible Air conditioning units Wall/ ceiling Mounted type complete with refrigerant piping with insulation ,condensate drain piping including Venture Cladding , fittings insulation,tape wraping etc , insulation,refrigerant charge thermostate ,control between indoor and outdoor units power wiring , conduiting , dura duct / channel mounting brackets and accessories complete in all respect.      
1204NS-07Split Air- Conditioner 1.5 tonJob4350000 1400000
1205NS-08Floor standing type Air- Conditioner 4 tonJob41200000 4800000
1206**EXTERNAL Electrical Works**      
1207**ELECTRICAL WORKS**      
1208**Conduits & Pipes**      
120924-3Supply and erection of PVC pipe for wiring recessed in walls, including inspection boxes, pull boxes, hooks, cutting jharries, and repairing surface, etc., complete with all specials.     
1210ii20 mm i/dRft.1000119.35 119350
1211iii25 mm i/dRft.1000138.95 138950
1212vi)50 mm i/dRft.3000238.15 714450
1213vii)80 mm i/dRft.1000299.65 299650
1214viii)100 mm i/dRft.2000377.65 755300
121524-105P/F PVC doublelayer Switch kit Faceplate with specified switch holes i/c the cost of switches / sockets / dimmer made of Legrand/ ABB / Schenide or approved equvilent manufacturer, screws complete as approved and directed by the Engineer Incharge     
1216a) One way Gange Switch (Small)     
1217(i) 01 Gange Each4463.2 1852.8
1218(ii) 02 Gange Each2704.4 1408.8
1219(iii)Three pin Light Plug 10/13 AmpEach5754.45 3772.25
1220(vii) Three Pin Power Plug 15-32 AmpEach10924.55 9245.5
1221**Wiring**      
122224-8Supply and erection of single core PVC insulated copper conductor cables, in prelaid PVC pipe/M.S. conduit/G.I pipe/wooden strip batten/wooden casing an capping/G.I. wire/trenches (rate for cables only):-     
1223c)450/750 volts, PVC insulated:     
1224ii)1.5 mm sq (3/0.029")Per Rft.200042.4 84800
1225iii)2.5 mm sq (7/0.029")Per Rft.200062 124000
1226iv)4 mm sq (7/0.036")Per Rft.400081.85 327400
1227**LT Cables**      
122824-10Supply and erection of single core PVC insulated, PVC sheathed copper conductor, 600/1000 volts grade cable, in prelaid G.I. pipe/M.S. conduits/PVC pipe/G.I. wire/trenches, etc (rate for cable only):-     
1229i)4 mm sq (7/0.036")Per Rft.10074.65 7465
1230ii)6 mm sq (7/0.044")Per Rft.100100.45 10045
1231iii)10 mm sq (7/0.052")Per Rft.200155.7 31140
1232iv)16 mm sq (7/0.064")Per Rft.200234.3 46860
1233v)25 mm sq (19/0.052")Per Rft.500358.5 179250
123424-11Supply and erection of copper conductor cables for service connection, in prelaid pipe/G.I. wire/trenches, etc. (rate for cable only):-     
1235b) Three core, 600/1000 volt cable:-     
1236iii) 7/0.74 mm (7/0.029")Per Rft.3000141.1 423300
1237c)PVC insulated, PVC sheathed 4 core, 600/1000 volt non armoured cable:-     
1238iv)4 mm sq (7/0.036")Per Rft.200268.75 53750
1239v)6 mm sq (7/0.044")Per Rft.100381.4 38140
1240vi)10 mm sq (7/0.052")Per Rft.250605.85 151462.5
1241vii)16 mm sq (7/0.064")Per Rft.2000926.05 1852100
1242viii)25 mm sq (19/0.052")Per Rft.6001426.2 855720
1243**Fans and Exhaust Fans**      
124424-102Providing and fixing Copper winded Exhaust fan with louver and shutter made of Pak/Younas/G.F.C. i/c the cost of necessary cable and hardware for connection from ceiling rose complete as approved and directed by Engineer Incharge.     
1245a)-iPlastic body - 10" diaEach25235.5 10471
124624-103Providing and fixing Pakistan Energy Label NEECA approved Copper winded wall bracket Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
1247ii)24" Sweep diaEach110703 10703
124824-104Providing and fixing Pakistan Energy Label NEECA approved Copper winded Ceiling Fan i/c the cost of necessary cable and hardware for connection as approved and directed by Engineer Incharge.     
1249(iii)56" diaEach110180.2 10180.2
1250**Lightning Protection System**      
125124-111Providing, making & testing/commissioning of Rod type Earth point comprising of 5/8" dia. (16 mm dia) 10 ft long copper coated M.S. rod driven in ground duly fixed with clamp with Tinned earth test link copper plate (300x50x10mm), i/c the cost of brass nuts,spacers, bolts washers plugs etc but excluding the cost of copper strand & manhole. as approved and directed by Engineer Incharge (Rod Type Earthing)P.Job8021210.95 1696876
125224-113Supply, installation, testing and commissioning of bare copper conductor for Earthing/ Grounding System     
1253viii) 70 mm² CU bare conductorPer Rft1000850.45 850450
1254**CCTV**      
125524-116Supply, Installation and commissioning of wiring with 4-pair data Cable, 23 AWG UL/EN listed cable * Conforming to following standards: TIA/EIA 568 / ISO/IEC 11801, in prelaid conduit / cable tray from including all accessories, Manufacturer/OEM Authorization, Make: Schneider / i-connect UK/3M Corning USA/ D-Link/ Pollo Australian or equivalent approved manufacturer, complete in all respect as approved and directed by Engineer Incharge.      
1256a)UTP (Unshielded Twisted pair)     
1257(i) CAT-6 (Min.1G @ 250MHz or higher) (for cctv and parking managemnet systemPer Rft650049.2 319800
125824-126Supply & Installation of NVR (Network Video Recorder) for Real TimeView of specified Channels, video and Audio channels,Supported protocoles: ONVIF,RTSP etc, Internal HDDs mount support:2/4/8 or higher as per site requirement,Monitor outputs,(HDMI,4K Ultra HD),VGA (Video Graphic array), Support Raid 5/6, Embeded OS, Data Encryption, Min. 1 x RJ-45 1000Mbps Ports, with PC Video Monitoring Software, Web Server, Embedded Server complete in all respect. made of AXIS Europe/NOVAS Europe/Avigilon by Motrola USA /Huawei, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge.     
1259iii)32-ChannelEach1131353.5 131353.5
126024-127Supply, Installation and Connection of Surveillance Grade Hard Drives (HDD) of Specified Capacity for CCTV System Backup. made of Seagate / WD, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge     
1261iii)10 TBEach269360 138720
126224-128Supply, Installation and Connection of L2 Access Switches 24xEthernet 10/100/1000 base-T port, min 2x1Gigabit SFP ports with 2x1G single mode SFP. POE/POE+. Switching capacity at least 200 Gbps full-duplex or higher supporting bi-directional ACL, port based ACL,VLAN based ACL, automatic Isolation of attack sources, DAI (Dyanamic ARP inspection), DHCP Snooping, IP Source Gaurd, port based network acess control conforming IEEE 802.1 x standard, Stackable or Cluster setup complete with Stack Modules, Stack cables, necessary licenses etc made of Cisco/HP/Planet/H3C/Huawei, Pollo Australia or equivalent approved manufacturer and directed by Engineer Incharge.Each1364102.5 364102.5
126324-129Supply, Installation and Connection of Layer-3, CoreSwitches, of specified speeds, supporting 10 Giga SFP+ (Small Form Pluggable +) Tranceiver, Switching Capacity at least 500 Gbps or higher ,supporting bidirectional ACL,port-based ACL., Stackable or Cluster setup complete with stacking cable, Stack modules, necessary licenses made of Cisco/ HP / Planet/Huawei/H3C Pollo Australia or equivalent approved manufacturer i/c the cost of tags as approved and directed by Engineer Incharge     
1264a)10/100/1000     
1265(i) 12 port(SFP)Each2645777.75 1291555.5
126624-130Supply and installation of ODF (Optical Distribution frame) having specified ports,mounting tray loaded, including Splicing, labeling, tagging, support for OM3 multi mode fibre, duplex adopters, and simplex pig-tails. Make Schneider, Pollo Australia or equivalent approved manufacturer and directed by the Engineer Incharge     
1267(ii) 12 PortEach169148.5 69148.5
126824-131Supply, Installation and Connection of Fiber Optic SC-LC Patch Cords OS2 or OM3 of Specified Length from PoE Switch to ODF Point, UL Listed, Made of Schneider / Norden ,Pollo Australia or equivalent as approved and directed by Engineer InchargeP.Rft5001922 961000
126924-132Supply, installation & connecting IP based Camera of specified resolution, 1/3" Progressive scan, fixed lens 2.8 mm AF, Max resolution 2592 x 1920 mm, Codec H-265, Camera with 25 fps, day night (ICR), ONVIF, IP-66, Max IR distance 30 meter, WDR Smart Analytics, i/c the cost of mounting bracket, mounting accessories/ materials. Make: - Honey Well / Bosch / Norden, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
1270b4 Mega PixeL     
1271(i)Fixed Bullet TypeEach2571535 1788375
127224-139Supply , installation of wall mounted CCTV Cabinet comprising of Powder Coated M.S frame, front glass & two side openings, 02 way fans for cooling, top & bottom entry, handle lock with 6 way PDU (Power Distribution Unit) with all necessary accessories/ materials, complete in all respects. Made of Bosch/ HP/ Dell , Pollo Australiaor equivalent or as approved and directed by Engineer Incharge     
1273ii15U size (600 x 550 x 770 mmEach259379.95 118759.9
127424-138Supply, installation and connections of HD Video Decoder that support digital video stream on network and allow for the decoding upto 16 simultaneous streams with HDMI cable as required at site. made of PELCO ( USA) /AXIS (Sweden) , Pollo Australia or equivalent as approved and directed by the Engineer Incharge.Each5641053.15 3205265.75
127524-136Supply, installation & connecting outdoor PTZ (Pan-Tilt-Zoom),IP based Camera of specified resolution, lens,motorized varfocal,AL & AF function,specified optical zoom,D/N function-IR cut filter,Video content analysis,micro SD card support, Min, illumination:face recognition, specified IR LED range RANGE i/c the cost of mounting bracket, accessories, made of AXIS Europe/NOVAS Europe/Avigilon by Motorla USA/Bosch Germany, Pollo Australia or equivalent, as approved as directed by the Engineer Incharge     
1276iii)4.0 MPxl, Optical zoom 30x,Digital zoom 16x,,laser distance 200 meter, Main stream H-264+/265+, sub stream H.264/265, Third Stream H.264/265, Max resolution 2560 x 1440 with 30 fps, IP-67Each1520635 520635
127724-69Supplying, installation testing and commissioning of Octagonal shape electric street light pole, made of hot dipped 4.5 mm thick (7 SWG) galvanized steel, tappered from 225 mm at bottom to 100 mm at top, with 1500 mm x 60 mm x 4mm thick dia. arm for luminaire installation, duly G.I.welded with 70x470x20 mm base plate with the help of 4 no triangular stiffeners 100x350x20 mm of GI sheet, with built in junction box with shutter, i/c the cost of nuts & J-rag bolts, duly fixed in prelaid concrete foundation, foundation will be paid additionally as approved and directed by the Engineer In charge     
1278 a) Single Arm     
1279(i) 8 mtr heightEach40107310.3 4292412
128024-70Supplying, installation and commissioning of LED Cobra-head Luminaries of specified wattage and lumens conforming to IP 66 & IK 08 or above Philips/Osram/Thorn or NEECA approved equivalent manufacturer with corrosion resistant die casted Aluminum housing, silicon gasket in special groove, UV stable & scratch resistant synthetic materials, thermally hardened glass complete with LED Chip (Philips Lumiled/Cree/Nichia/Osram make or equivalent approved manufacturer), programmable LED driver (Harvard/TCI/Lumotech/Philips/VOSSLOH Schwabe/Lightech make or approved equivalent manufacturer), minimum 10kV surge protection rating device i/c the cost of all accessories/components required for proper operation, fully flexible for future upgradation and easy replacements for maintenance purposes, bucket elevator charges as approved and directed by the Engineer Incharge.      
1281a) 140 Lm/Watt      
1282iv) 90 Watt with 12600 LumensEach4041540.4 1661616
128324-93P/F PFI PLANT (Power Factor Improvement Plant) comprising ofcomponents of required ratitngs, in MS box of 14 SWG i/c the cost of 3mm thick Backlite sheet (Safety Sheet) Lock, thimbles, power capacitors, Magnetic contactors, HRC fuses, Power factor controllers, Indication lights, Copper comb, Wiring, Netural & Earth bar, Door earthing, brass glands, push buttons, CTS, Controle MCB, Surge Suppressors, Auto/Manual Switches, Exhaust Fan, Temp regulators as per WAPDA standards complete in all respects as approved and directed by the Engineer Incharge.      
1284i) 62.5KVArEach1269555 269555
128524-85Suppling,Installation and comissioning of MCB (Miniature Circuit Breaker) of specified rating made of LEGRAND FRANCE/ GE U.S.A / SCHNEIDER GERMANY /SIEMEN GERMAN/TERASAKI JAPAN/ SWITZERLAND or approved equivalent manufacturer in prelaid DBs and Panels i/c the cost of screwes,necessary wire complete in all respect as approved and directed by the Engineer Incharge     
1286a) Single Pole     
1287(iii) 6-63 Amp (10 KA) Each481459.05 70034.4
1288b) Double Pole     
1289iii) 6-63 Amp (10 KA)Each25621.55 11243.1
129024-86Supplying ,Installation and commissioning of MCCB FRANCE/ GE U.S.A / SCHNEIDER GERMANY / TERASAKI JAPAN/SIEMEN/ABB SWITZERLAND or approved equivalent manufacturer (with fixed Thermal-Magnetic Trip ) in prelaid DBs and Panels i/c the cost of screws, necessary wire complete in all respect as (Moulded Case Circuit Breaker) of specified rating made of LEGRAND approved and directed by the Engineer Incharge     
1291a) Triple Pole     
1292(iii) 15-100 Amp(18 KA)Each212172.95 24345.9
1293viii) 125-150 Amp(36 KA)Each126516.7 26516.7
129424-90(Recessded/Surface mounted Type), Powder coated Paint, i/c the cost of Lock, Indication lights, Thimble, Copper Comb, Wiring, Netural & Earth Bar, Door Earthing, Digital Voltmeter ,Digital Ammeter, Volt Selector Switch,Ammeter selector switch, Current Transformers and Controles Complete in all respect as approved and directed by the Engineer P/F wall mounted DB (Distribution Board) made with 16SWG Sheet Incharge (Breakers will be Paid Separately).      
1295(a) 6" deep     
1296(i) 20~60A P.CFT202463.7 49274
1297ii) 75~100AP.CFT102604.4 26044
129824-92P/F floor mounted ATS (Auto Transfer Switch) panel board , fabricarted with 14S WG M.S sheet (Indoor Type) duly painted with 100 microns powder coated paint in approved colour, front access, extendable, insulation class of 600 volts IP-44, incomimg & outgoing connections from bottom with flexible copper cable suitable for 415 VAC, 3-phase 4 wire, 50 HZ TPN&E system having rated service, short circuit breaking capacity at 400VAC conformimg to IEC-947-2 to accomodate given no of circuit components, instruments & accessories,assembled & wired with Electrolitic Copper bus bars at 50 deg and cables duly cleaned down to bare shining metal phosphate, manual change Over i/c the cost of Lock, Indication lights, Brass glands, Netural & Earth bar, thimbles, Digital volt meter/ Amp meter, Selector switch, Current transformers, Controles, Channels, Copper bus bars of specified capacity, Relays, Door Earthing, complete in all respects as approved and directed by the Engineer Incharge. (Breakers wil be paid additionally)      
1299 b) 2.00 Ft deep (i)125-250 KVA Each12349389.05 2349389.05
130024-94Providing and fixing DB/Panel accessories of required rating and size i/c copper screws of approved brand Complete in all respect as approved and directed by the Engineer Incharge     
1301i)Selector SwitchEach51228.8 6144
1302(ii)Current Transformer Coil (Make: Metelx/Fico)Each102134.3 21343
1303(iii)Digital Voltmeter (0-600 Volt)Each41012.8 4051.2
1304(iv)Digital Ammeter (0-9999 Amp)Each101228.8 12288
1305(v)LED Phase IndicatorEach12622.8 7473.6
1306(vi) Push Button ON/OFF (Make: Schneider/Himal/Eqv.)Each15631.15 9467.25
1307vii)Auxiliary Contactor. (Make: Schneider/ Terasaki/ABB)Each185373.8 96728.4
1308viii) Control MCB S/P 6A (Make: Schneider/ Terasaki/ABB)Each181375.8 24764.4
1309ix)Surge SuppressorsEach61060.8 6364.8
1310x) Auto/Manual Switch 3-Steps (Make: GGT/Camsco)Each52257.8 11289
1311xi)Exhaust Fan with Louvers (Make: Imported/PlastimEach53832.8 19164
1312xii)Temperature Regulator 0~60CEach62134.3 12805.8
1313xiii)(Power CapacitorsEach    
1314a) 12.5 KVAREach116852.8 16852.8
1315b) 25 KVAREach125852.8 25852.8
1316c) 50 KVAREach166052.8 66052.8
1317(d) 100 KVAREach1188030.4 188030.4
1318 Magnetic Contactor     
1319(a) 25 A (AC 3) for 12.5 KVAREach210048.8 20097.6
1320b) 40 A (AC 3) for 25 KVAREach314332.8 42998.4
1321© 80 A (AC 3) for 50 KVAREach226932.8 53865.6
1322(xvii)Power Factor Controller      
1323a) 6 StepsEach155252.8 55252.8
1324b) 12 StepsEach164252.8 64252.8
1325**Non - Schedule Items**      
1326**HT CABLES & SYSTEM (8.7/15 kV)**      
1327 (Ref. Specification Section-8001 8211 )     
1328NS-01Supply & Installation of 1 core, 240 mm2 8.7/15 kV Aluminum conductors, XLPE cable as per requirements of the MV distribution system as per WAPDA/IESCO standards.Meter405100 204000
1329 TRANSFORMERS     
1330NS-02Supply, Installation, testing , Commissioning, of Outdoor type 400KVA, three phase, 11/0.415 kV PAD mounted transformer.The complete unit shall be designed, fabricated and commissioned as per latest WAPDA's technical specifications. It shall also include the cost of mounting and installation material. Job16240000 6240000
1331 Light Fixtures     
1332 Ref. Specs Sec. 8001, 8150     
1333 Supply, installation, testing & commissioning of following LED Light fixtures complete with Electronic ballast (unless mention otherwise), lamps, lamp holders,SPD, Earth Protection and mounting accessories etc., as per specification, complete in all respects, as per drawings and specification, complete in all respect. Lighting fixtures sample must be submitted to consultant for approval. PF> 0.9, CRI>80, 110 Lumens/watt. Operating Life 30,000hrs, IEC Certified. Note: Refer light fixtures drawings/Schedule for complete light fixtures details.     
1334NS-1510 W LED Flood light with bult in integrated driver and frosted glass diffuser IP 65 No.105600 56000
1335NS-16200 W LED Flood light with bult in integrated driver and frosted glass diffuser IP 65 No.6055000 3300000
1336NS-17Outdoor type LED Bollard light of minimum 1800 lumens light output, IP-55 or better ratedNo.4025000 1000000
1337 LOW VOLTAGE D.G. SET Ref. Spec. Sec. 8001, 8111, 8240.     
1338NS-28Supply, installation , testing and commissioning of 300 kVA, Prime Rating 415 volt D.G. Set skid mounted including control / Instrument Panels, generator Panel, fuel day tank and all accessories along with Sound proof Canopy, manufactured for 300 kVA Prime D.G. Set. etc. complete in all respect including factory testing expenditure as mentioned in Clause 13 of Section 8001.Job.123700000 23700000
1339**FIREFIGHTING WORKS**      
1340**Schedule Items**      
1341**BILLIARD ROOM**      
134223 / 54Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge:     
1343i)Dry Chemical Powder capacity 6 KgEach113329.6 13329.6
1344ii)CO2 Capacity 5 kg.Each133067.2 33067.2
1345**CAFÉ / CIGAR ROOM**      
134623 / 54Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge:     
1347i)Dry Chemical Powder capacity 6 KgEach213329.6 26659.2
1348ii)CO2 Capacity 5 kg.Each233067.2 66134.4
1349iv)K-Type wet chemical capacity 6 Litters.Each248232.8 96465.6
1350**SWIMMING POOL**      
135123 / 54Providing and fixing of fire extinguishers of following type and capacities complete in all respect as approved and directed by the Engineer Incharge:     
1352i)Dry Chemical Powder capacity 6 KgEach313329.6 39988.8
1353ii)CO2 Capacity 5 kg.Each233067.2 66134.4
1354**Non-Schedule Items**      
1355**PUMPING MACHINERY**      
1356NS-01Automatically operated submersible drainage pump set to be installed in Basement-sump pit, comprising 01No. pump (minimum particle passage : 25mm) including all accessories, pulling chain, Motor Control panel, level switches, gate valves, non return valves, manual tools spare parts, complete in all respects as per drawings and specs of approved make, pump of the following capacity and pumping head. Capacity = 30 gpm Head =02BarsJob1708000 708000
1357**PEDAL COURT**      
1358**ELECTRICAL WORKS-BUILDING**      
1359**Non-Schedule Items**      
1360NSI-01Providing and Supplying Electricity and Lights Wiring with 7/29 Guage Wire (Pakistan Cable/Fast Cable) 4 x Lights 350 watts each Philips Lumileds Luxeon 3030 2D Model Life Span of PCB: 50,000hrs Light Source Efficiency (Im/w): 210lm/w Driver Brand: Philips IP Class: Module IP 66 complete in all respects.No4165938 663752
1361**BOX CRICKET /FUTSAL GROUND**      
1362**ELECTRICAL WORKS-BUILDING**      
1363**Non-Schedule Items**      
1364NSI-05Providing and Supplying Electricity and Lights Wiring with 7/29 Gauge Wire (Pakistan Cable/Fast Cable) Lights 200 watts each Philips Lumileds Luxeon 3030 2D Model Life Span of PCB: 50,000hrs Light Source Efficiency (Im/w): 210 lm/w Driver Brand: Philips IP Class: Module IP 66 complete in all respects.No1439515 553210
1365** PROVISIONAL SUM **      
1366 Lump Sum Provision  100000000 100000000
GRAND TOTAL:Rs 496,583,040.16

Scope of Work

All componenets in accordance with BOQ

Price Schedule

For Individual Jobs

# Job Title Quantity Unit Price (PKR) Total Price (PKR) Delivery Location Delivery Period / Year Country of Origin
1
2
For Lots
# Lot Title Total Lot Price (PKR) Country of Origin
1[Lot 1 Title]

📑 General Conditions of Contract (GCC)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

Red Book:
© FIDIC 2017. All rights reserved.

The Conditions of Contract are the “General Conditions” which form part of the “Conditions of Contract for Construction for Building and Engineering Works Designed by the Employer (“Red book”) Second edition 2017” published by the Federation Internationale Des Ingenieurs – Conseils (FIDIC) and the following “Particular Conditions” which shall complement the General Conditions of the Contract.

The successful Bidder, upon contract award, shall be required to furnish two (02) copies of aforementioned “General Conditions” for incorporation in the Works Contract.

International Federation of Consulting Engineers (FIDIC) FIDIC
Bookshop – Box- 311 – CH – 1215 Geneva 15, Switzerland
Fax: +41 22 799 49 054
Telephone: +41 22 568 0500
E-mail: fidic@fidic.org
Website:
www.fidic.org
FIDIC code: ISBN13: 978-2-88432-084-9

📑 Special Conditions of Contract (SCC)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

PARTICULAR  CONDITIONS OF CONTRACT (PCC)

Particular Conditions
(Mandatory Provisions not to be amended/substituted) 

The Particular Conditions (PCC) complement the General Conditions (GCC) to specify dates, contractual requirements, and special circumstances related to the Works. The PCC consists of two parts, Part A - Contract Data and Part B - Special Provisions. The provisions to be found in the Special Provisions (Particular Conditions - Part B) take precedence over the equivalent provisions found under the same Sub-Clause number(s) in the General Conditions, and the provisions of the Contract Data (Particular Conditions - Part A) take precedence over the Special Provisions (Particular Conditions - Part B).

PART A - Contract Data

Sub-Clause 1.1.27
Defects Notification Period (DNP): 365 Days

Sub-Clause 1.1.31 
Employer's name & address: Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad

Sub-Clause 1.1.35 
Engineer's name & address: Concerned Member 

Executive Block, CDA Secretariat G-7/4, Islamabad

Sub-Clause 1.1.84
Time for Completion: 120 days for whole of the works

Sub-Clause 1.3 (a)(ii)
Agreed method of electronic transmission: Not Agreed

Sub-Clause 1.3 (d)
Address of Empoyer for Communications: Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
Address of Engineer for Communications: 

Executive Block, CDA Secretariat G-7/4, Islamabad


Address of Contractor for Communications: -----------------------------

Sub-Clause 1.4
Contract shall be governed by the law of:    Islamic Republic of Pakistan
Ruling language: English
Language for communications: English

Sub-Clause 2.1
After receiving the Letter of Acceptance, the Contractor shall be given right of access to all or part of the Site within: 14 days after Commencement Date

Sub-Clause 2.4
Employer’s financial arrangements:

Through CDA's own resources

Sub-Clause 3.2 (e)(ii)
Engineer’s Duties and Authority: Variation resulting in an increase of the Accepted Contract Amount in excess ofone percent (1%)subject to accumulative Variations not exceeding five percent (5%)of the Accepted Contract Amount 

Sub-Clause 4.2
Performance Security (as percentage of the Accepted Contract Amount in Currencies): 10.00%
Form of Performance Guarantee: Bank Guarantee

Sub-Clause 4.2.1
List of Insurance Companies:

Only Bank Guarantee

Sub-Clause 4.7.2
period for notification of errors in the items of reference: Twenty Eight (28) days

Sub-Clause 4.19
Period of payment for temporary utilities: Each Month

Sub-Clause 5.1 (a)
Maximum allowable accumulated value of work subcontracted (as a percentage of the Accepted Contract Amount): Nil %

Sub-Clause 5.1 (b)
Parts of the Works for which subcontracting is not permitted: Nil

Sub-Clause 6.5
Normal working hours on the Site: 8

Sub-Clause 8.3
Number of additional paper copies of programmes: 3

Sub-Clause 8.8 & 14.15(b)
Delay Damages payable for each day of delay 0.10% of the Accepted Contract Amountfor delay in completion of whole of the Works

Sub-Clause 8.8
Maximum amount of Delay Damages    10.00 % of the Accepted Contract Amount

Sub-Clause 8.14
Applicability of Incentives for Early Completion    No

Sub-Clause 12.3
Percentage profit (Not more than 10%):    Nil

Sub-Clause 13.4.(b)(ii)
Percentage rate to be applied to Provisional Sums for overhead charges and profit: Twenty Five percent (25%)

Sub-Clause 14.2
Total Advance Payment: Fifteen percent (15%) of the Accepted Contract Amount excluding Provisional Sums payable in the currencies and proportions in which the Accepted Contract Amount is payable

Sub-Clause 14.2.1
Advance Payment Insurance Not Allowed

Sub-Clause 14.2.3
Percentage deductions for the repayment of the Advance Payment: Deduction shall be made at the amortization rate of 17.5 % of the value of the Works executed of each IPC as provided in paragraph (i) of Sub-Clause GCC 14.3, starting from 2nd IPC provided that the advance payment shall be completely repaid prior to the time when 90% of the Accepted Contract Amount less Provisional Sums has been certified for payment. It may be more than 17.5% in the last instalment to ensure full repayment.

Sub-Clause 14.3
Period of payment    One Month

Sub-Clause 14.3(b)
Number of additional paper copies of Statements: 3

Sub-Clause 14.3 (iii)
Percentage of retention: Seven percent (7%)

Sub-Clause 14.3 (iii)
Limit of Retention Money (as a percentage of the Accepted Contract Amount): Five percent (5%)

Sub-Clause 14.5(b)(i)
Plant and Materials for payment when shipped: Plant and Materials under Bill of “Imported Plant and Materials” 

Sub-Clause 14.5(c)(i)
Plant and Materials for payment when delivered to the Site: Plant and Non Perishable Materials 

Sub-Clause 14.6.2
Minimum amount of Interim Payment Certificate (IPC): Yes
The Minimum Amount IPC is 15000000

[Employer to give value not exceeding one fifth of the average expected value of Interim Payment Certificate]

Sub-Clause 14.7(a)
Period of payment of Advance Payment to the Contractor: 14 days

Sub-Clause 14.7b(i)   
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.6:    28 days

Sub-Clause 14.7b(ii)
Period for the Employer to make interim payments to the Contractor under Sub-Clause 14.13 (Final Payment): 28 days 

Sub-Clause 14.7(c)
Period for the Employer to make final payment to the Contractor: 56 days 

Sub-Clause 14.8
Financing charges for delayed payment Local Currency (PKR):
6-Month KIBOR (Offer) +3% per annum.
Foreign Currency: 
USD
6-Month SOFR (Secured Overnight Financing Rate for USD) +1% per annum.

EURO
6-Month EURIBOR (EURO Interbank Offered Rate for EURO) +1% per annum.

Others
Appropriate rates +1% (for other foreign currencies, Ref. Schedule-A, A-4 to Bid).

Sub-Clause 14.11.1(b)
Number of additional paper copies of draft Final Statements: 3
[insert number of copies say six (06)]

Sub-Clause 14.15
Currencies of payment of Contract Price: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)

Sub-Clause 14.15(a)(i)
Proportions or amounts of Local and Foreign currencies: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)

Sub-Clause 14.15(c)
Currencies and proportions for payment of Delay Damages: as stated in the Table Schedule of Adjustment Data of Schedule A (if Given)

Sub-Clause 14.15(f)
rates of exchange: as stated in the Table IV of Schedule A (If Given)

Sub-Clause 17.2(d)
Forces of nature, the risks of which are allocated to the Contractor: Nil

Sub-Clause 19.1
Permitted deductible limits: 
i)    insurance required for the Works: Ten percent (10%) of loss amount on each & every loss
ii)    insurance required for Goods: Nil
iii)    insurance required for liability for breach of professional duty: Nil
iv)    insurance required against liability for fitness for purpose (if any is required): Nil
v)    insurance required for injury to persons and damage to property: Nil
vi)    insurance required for injury to employees: Nil
vii)    other insurances required by Laws and by local practice : Nil  

Periods for submission of insurance:
a)    evidence of insurance: Not later than the Commencement Date
b)    relevant policies: Within twenty eight (28) day from the Commencement Date

Sub-Clause 19.2.1(b)
Additional amount to be insured (as a percentage of the replacement value): 15% of the replacement value (Accepted Contract Amount)
Sub-Clause 19.2.2 
Extent of insurance required for Goods: From Ex-Works (i.e., works, factory, warehouse, etc) to delivery at the Site
Amount of insurance required for Goods: Full replacement value

Sub-Clause 19.2.3(a)
Amount of insurance required for liability for breach of professional duty: Full replacement value of the Works to be designed by the Contractor

Sub-Clause 19.2.3(b)
Insurance required against liability for fitness for purpose: Yes

Sub-Clause 19.2.3
Period of insurance required for liability for breach of professional duty: Until the date of issuance of Performance Certificate

Sub-Clause 19.2.4
Amount of insurance required for injury to persons and damage to property: Injury to person and Fatal case: 
in accordance with Workmen Compensation Act
Damage to Property: The Amount of Insurance Required for Person Injury is 2000000
The Amount of Insurance Required for Damage to Property is 5000000 as per his assessment of the adjoining property(ies) other than the Works]
without limit to the number of incidents

Sub-Clause 19.2.6
Other insurances required by Laws and by local practice: All insurances as applicable, to the extent of execution of the project, under Federal and Provincial laws of Islamic Republic of Pakistan

Sub-Clause 21.1
Time for appointment of the DAAB: Within 28 days from the Commencement Date.
In case the Accepted Contract Amount is lesser than PKR one (01) billion, appointment of the DAAB shall be made when Dispute arises between the Parties.

Sub-Clause 21.1
The DAAB shall comprise  1
[insert either “a sole Member” or “Three Members”]
[For a Contract estimated to cost above PKR 2.5billion, the DAAB shall comprise of three members. For a Contract estimated to cost between PKR1billion and PKR2.5billion, the DAAB may comprise of three members or a sole member. For a Contract estimated to cost less than PKR1billion, a sole member is recommended.]

Sub-Clause 21.1
List of proposed members of DAAB
- proposed by Employer

Dr. Shahid Mehmood


- proposed by Contractor
[to be inserted at the time of signing of the Contract]
1.________________
2.________________
3.________________

Sub-Clause 21.2
Appointing entity (official) for DAAB members    Managing Director Public Procurement Regulatory Authority (PPRA) or Chairman Pakistan Engineering Council (PEC) from the list of PEC approved arbitrators published at its website

Sub-Clause 21.6
Rules of Arbitration: PEC Rules of Conciliation and Arbitration or Pakistan Arbitration Act of 1940, if the former is inactive.
The place of Arbitration shall be in the Employer’s country: Islamabad , Pakistan
[Insert name of city]

 

Particular Conditions

PartB - Special Provisions

1.1    Definitions

1.1.76 “Specification”
Following is added at the end:
“and consists of two parts i.e.,
i)    “Part A - Specific Provisions”; and 
ii)    “Part B - Technical Provisions”.”

1.2    Interpretation

“and” is deleted from the end of sub-paragraph (i) and added at the end of sub-paragraph (j). 
Sub-paragraph (k) is added:
“(k)    The word “tender” is synonymous with “bid” the word tenderer with “bidder”, the words “tender documents” with “bidding documents” and “Schedule of Prices” with “Bill of Quantities”, as applicable.”
1.5    Priority of Documents    The documents listed at (a) through (k) of this Sub-Clause are deleted and substituted with the following:
(a)    the Contract Agreement;
(b)    the Letter of Acceptance;
(c)    the Letter of Bid;
(d)    the Particular Conditions Part A - Contract Data;
(e)    the Particular Conditions Part B - SpecialProvisions;
(f)    the General Conditions;
(g)    the Specification Part A - SpecificProvisions;
(h)    the Specification Part B- Technical Provisions;
(i)    the Drawings;
(j)    the completed Schedules to Bid includingBillof Quantities;
(k)    the JV Undertaking (if the Contractor is a JV); and
(l)    any other documents forming part of the Contract.
The addenda/corrigenda, if any, shall be deemed to have been incorporated at the appropriate places in the documents forming the Contract.

1.6    Contract Agreement

In the last line of the 1st paragraph the text “shall be borne by the Employer” is substituted by “shall be reimbursed by the Employer to the Contractor”.

3.1    The Engineer

In sub-paragraph (a) the text “as defined in the Pakistan Engineering Council Act, 1975 (Act No.V of 1976)” are added after the words “professional engineer”.

3.2    Engineer’s Duties and Authority

The Engineer shall obtain the consent in writing of the Employer before taking action under the following Sub-Clauses of these Conditions:
(a)    Consenting to the subcontracting of any part of the Works under Sub-Clause 5.1 [Subcontractors]
(b)    Any action under Sub-Clauses 8.9 [Employer’s Suspension] and 8.12 [Prolonged Suspension]
(c)    Issuance of “Taking Over Certificate” under Sub-Clause 10.1 [Taking Over the Works and Sections].
(d)    Issuing the “Performance Certificate” under Sub-Clause 11.9 [Performance Certificate].
(e)    Sub-Clause 13.1 [Right to Vary]: instructing a Variation, except;
(i)    in an emergency situation as determined by the Engineer, or
(ii)    if such a Variation would increase the Accepted Contract Amount by less than the percentage specified in the Contract Data.
(f)    Sub-Clause 13.3 [Variation Procedure]: approving a proposal for Variation submitted by the Contractor in accordance with Sub-Clause 13.3.2 [Variation by Request for Proposal] or 13.2 [Value Engineering].
(g)    Certifying release of second half of the Retention Money under Sub-Clause 14.9 [Release of Retention Money].
(h)    Issuing Final Payment Certificate under Sub-Clause 14.13 [Issue of FPC].
(i)    

Issue of FPC Sub Clauses

Determination


*[insert Sub-Clause number (not Sub-Clause 3.7 [Agreement or Determination]
Any such requirement shall not be applied to any action by the Engineer under Sub-Clause 3.7 [Agreement or Determination], as stated in Sub-Clause 3.2 [Engineer’s Duties and Authority] of the General Conditions.
Notwithstanding the obligation, as set out above, to obtain approval, if, in the opinion of the Engineer, an emergency occurs affecting the safety of life or of the Works or of adjoining property, he may, without relieving the Contractor of any of his duties and responsibility under the Contract, instruct the Contractor to execute all such work or to do all such things as may, in the opinion of the Engineer, be necessary to abate or reduce the risk. The Contractor shall forthwith comply, despite the absence of approval of the Employer, with any such instruction of the Engineer. The Engineer shall determine an addition to the Contract Price, in respect of such instruction, in accordance with Clause 13 and shall notify the Contractor accordingly, with a copy to the Employer.
Following is added after the words “the Employer’s consent is required” in 4th paragraph:
“stating that the Employer’s consent has been obtained for that specified authority”

4.2    Performance Security

4.2.1    Contractor’s Obligations
The entity issuing the Performance Security and its form shall be as under:
The Performance Security shall be, at the option of the Contractor,issuedin the prescribed form included in the Bidding Documents,by(a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistan or (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofratingas provided in Table below:
Accepted Contract Amount (In Eq. PKR million)    Minimum Rating of Insurance Companies
Up to 1000    A (+)
1001 to no limit    AA
In case of Joint Venture, the Performance Security shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.
Following paragraph is added at the end of this Sub-Clause:
“The amount of Performance Security shall be reducedto 50%following issue of the Taking-Over Certificate for the whole of the Works under Clause 10 of Conditions of Contract.”

4.3    Contractor’s Representative

In second paragraphthe text “professional engineer as defined in the Pakistan Engineering Council Act, 1975 (Act No. V of 1976) (having temporary licence in case of foreign engineer under Section 12 of the Pakistan Engineering Council Act, 1975 (Act No. V of 1976)” are added after the words “qualified, experienced”.
In the 3rd paragraph the words “28 days” are substituted by “14 days”. In 2nd line of 4thparagraph the text “or appoint a replacement” is substituted by “except appointment of a suitable temporary replacement is deployed at the Site”

4.4    Contractor’s Documents

4.4.2    As-Built Records
First paragraph is deleted and the text in the last paragraph is substituted with the following:
“The Contractor shall furnish to the Engineer 6 copies, one reproducible and one electronic copy(provided the Engineer has made available to the Contractor editable form of the Drawings)of all Drawings amended to conform to the Works as built.In case the Engineer does not make available to the Contractor editable form of the Drawings, the Contractor shall furnish to the Engineer as-built data for incorporation in the Drawings. Upon receipt of PDF versions of the as-built drawings prepared by the Engineer, the Contractor shall furnish to the Engineer 6copies and one reproducible of these Drawings.
The price of such Drawings shall be deemed to be included in the Contract Price.”
Following Sub-Clause is added:
4.4.4    ShopDrawings
The Contractor shall submit to the Engineer for review 3 copies of all shop and erection drawings applicable to this Contract as per provision of relevant Sub-Clause of the Contract.
Review and approval by the Engineer shall not exceed 21 days and be construed as a complete check but will indicate only that the general method of construction and detailing is satisfactory and the Engineer’s review or approval shall not relieve the Contractor of any of his responsibilities under the Contract.

4.8    Health and Safety Obligations

The following text is added at the end ofthis Sub-Clause:
In the event of work being carried out outside the normal working hours and in the event of work being carried out at night, the Contractor shall at his own cost, provide and maintain such good and sufficient light as will enable the work to proceed satisfactorily and without danger. The approaches to the Site and the Works where the night work is being carried out shall be sufficiently lighted. All arrangement adopted for such lighting shall be to the satisfaction of the Engineer.

4.20    Progress Reports

At the end of sub-paragraph (g) the word “and” is deleted and at the end of sub-paragraph (h) the full stop (.) is replaced with “;”, and the following new sub-paragraphs are added as:
(i)    planned programme for the execution of the Works for next 56 days to enable the Engineer to determine its programme of inspection and testing;
(j)    monthly summery of daily job record indicating weather conditions, deployment of Contractor’s Equipment, labour employment, local material procurement and material import, if any; and
(k)    salient contractual and project information.

5.1    Subcontractors

Add the following text at the end of paragraph (ii):
“underSchedule to Bid”
The following is added at the end of the last paragraph of Sub-Clause 5.1:
“All subcontracts relating to the Works shall include provisions which entitle the Employer to require the subcontract to be assigned to the Employer under sub-paragraph (a) of Sub-Clause 15.2.3 [After Termination].
The Contractor shall give reasonable opportunity to contractors from Islamic Republic of Pakistan for subcontracts for the Works, and endeavour to employ such contractors as Subcontractors.”

5.2    Nominated Subcontractors

5.2.2    Objection to Nomination
In sub-paragraph (c), “and” is deleted from the end of (i);
 “.” at the end of (ii) is replaced with: “, and”. 
The following is then added as (iii):  
“(iii)    be paid only if and when the Contractor has received from the Employer payments for sums due under the Subcontract referred to under Sub-Clause 5.2.3 [Payment to nominated Subcontractors].”

6.1    Engagement of Staff and Labour

The following paragraph is added at the end of the Sub-Clause:
“The Contractor shall, to the extent practicable and reasonable, employ staff (not less than 50%) and labour (not less than 85%) with appropriate qualifications and experience from sources within the Islamic Republic of Pakistan.”

6.7    Health and Safety of Personnel

The existing text is substituted with the following:
“In order to provide for the safety, health and welfare of persons, and for prevention of damage of any kind, all operations for the purposes of or in connection with the Contract shall be carried out in compliance with the Safety Requirements of the Government of Pakistan with such modifications thereto as the Engineer may authorize or direct and the Contractor shall take or cause to be taken such further measures and comply with such further requirements as the Engineer may determine to be reasonably necessary for such purpose. The Contractor shall also provide all other medical services and appoint a health and safety officer at Site if stated in the Specifications. In case of any fatality or serious accident, the Contractor shall, in addition, notify the Engineer immediately by the quickest available means.”

6.8    Contractor’s Superintendence

Insert at the end of sub-paragraph (a) of this Sub-Clause:
"or, if not, the Contractor shall make competent interpreters available during all working hours, in a number sufficient for those persons to properly perform their superintendence duties"
The following text is added at the end of this Sub-Clause: 
“The Contractor’s authorized representative and his other engineers working at site shall possess valid registration with the Pakistan Engineering Council.
The Contractor’s authorized representative at Site shall be authorized to exercise adequate administrative and financial powers on behalf of the Contractor so as to achieve completion of the Works as per the Contract.”

6.12    Key Personnel

The following is inserted at the end of the last paragraph: 
“If any of the Key Personnel are not fluent in this language, the Contractor shall make competent interpreters available during all working hours in a number deemed sufficient by the Engineer.”
The following Sub-Clauses 6.13 to 6.26 are added at the end of Sub-Clause 6.12:

6.13    Foreign Personnel

The Contractor may bring in to the Country any foreign personnel who are necessary for the execution of the Works to the extent allowed by the applicable Laws. The Contractor shall ensure that these personnel are provided with the required residence visas and work permits. The Employer will, if requested by the Contractor, use all reasonable endeavours in a timely and expeditious manner to assist the Contractor in obtaining any local, state, national, or government permission required for bringing in the Contractor’s personnel.
The Contractor shall be responsible for the return of these personnel to the place where they were recruited or to their domicile. In the event of the death in the Country of any of these personnel or members of their families, the Contractor shall similarly be responsible for making the appropriate arrangements for their return or burial.

6.14    Supply of Foodstuffs

The Contractor shall arrange for the provision of a sufficient supply of suitable food as may be stated in the Specification at reasonable prices for the Contractor’s Personnel for the purposes of or in connection with the Contract.

6.15    Supply of Water

The Contractor shall, having regard to local conditions, provide on the Site an adequate supply of drinking and other water for the use of the Contractor’s Personnel.

6.16    Measures against Insect and Pest Nuisance

The Contractor shall at all times take the necessary precautions to protect the Contractor’s Personnel employed on the Site from insect and pest nuisance, and to reduce the danger to their health. The Contractor shall comply with all the regulations of the local health authorities, including use of appropriate insecticide.

6.17    Alcoholic Liquor or Drugs

The Contractor shall not, otherwise than in accordance with the Laws of the Country, import, sell, give, barter or otherwise dispose of any alcoholic liquor or drugs, or permit or allow importation, sale, gift, barter or disposal thereto by Contractor’s Personnel.

6.18    Arms and Ammunition

The Contractor shall not give, barter, or otherwise dispose of, to any person, any arms or ammunition of any kind, or allow Contractor’s Personnel to do so.

6.19    Festivals and Religious Customs

The Contractor shall respect the Country’s recognized festivals, days of rest and religious or other customs.

6.20    Funeral Arrangements

The Contractor shall be responsible, to the extent required by local regulations, for making any funeral arrangements for any of its local employees who may die while engaged upon the Works.

6.21    Forced Labour

The Contractor, including its Subcontractors, shall not employ or engage forced labour which consists of any work or service, not voluntarily performed, that is exacted from an individual under threat of force or penalty, and includes any kind of involuntary or compulsory labour, such as indentured labour, bonded labour or similar labour-contracting arrangements.

6.22    Child Labour

The Contractor, including its Subcontractors, shall not employ or engage child labour in accordance with relevant law(s) in force in Islamic Republic of Pakistan.

6.23    Employment Records of Workers

The Contractor shall keep complete and accurate records of the employment of labour at the Site. The records shall include the names, ages, genders, hours worked and wages paid to all workers. These records shall be summarized on a monthly basis and submitted to the Engineer. These records shall be included in the details to be submitted by the Contractor under Sub-Clause 6.10 [Contractor’s Records].

6.24    Workers’ Organizations

The Contractor shall comply with the relevant labour laws of Pakistan which recognize workers’ rights to form and to join workers’ organizations/Trade Union of their choosing and to bargain collectively without interference.

6.25    Non-Discrimination and Equal Opportunity

The Contractor shall not make decisions relating to the employment or treatment of Contractor’s Personnel on the basis of personal characteristics unrelated to inherent job requirements. The Contractor shall base the employment of Contractor’s Personnel on the principle of equal opportunity and fair treatment, and shall not discriminate with respect to any aspects of the employment relationship, including recruitment and hiring, compensation (including wages and benefits), working conditions and terms of employment, access to training, job assignment, promotion, termination of employment or retirement, and disciplinary practices. 
Special measures of protection or assistance to remedy past discrimination or selection for a particular job based on the inherent requirements of the job shall not be deemed discrimination. The Contractor shall provide protection and assistance as necessary to ensure nondiscrimination and equal opportunity, including for specific groups such as women, persons with disabilities, migrant workers and children (of working age in accordance with Sub-Clause 6.22).

6.26    Epidemics   

In the event of any out-break of illness of epidemic nature, the Contractor shall comply with and carry out such regulations, orders and requirements as may be made by the Government or the local medical or sanitary authorities for the purpose of overcoming the same.

7.7    Ownership of Plant and Materials

The following is added before the first paragraph:
“Except as otherwise provided in the Contract,” 
The following is added at the end of the Sub-Clause:
"No Plant and/or Materials that is the property of the Employer shallbe removed from the Site. If it becomes necessary to:
(i)    remove any item of such Plant from the Site for the purposesof repair, the Contractor shall give a Notice, with reasons, tothe Engineer requesting consent to remove the defective ordamaged item off the Site. This Notice shall clearly identifythe item of defective or damaged Plant, and shall give detailsof: the defect or damage to be repaired; the place to whichdefective or damaged item of Plant is to be taken for repair;the transportation to be used (and insurance cover for suchtransportation); the proposed inspections and testing off theSite; and the planned duration required before the repaireditem of Plant shall be returned to the Site. The Contractorshall also provide any further details that the Employer mayreasonably require; or
(ii)    replace any item(s) of such Plant and/or Materials, theContractor shall give a Notice, with reasons, to the Engineerclearly identifying the item(s) of Plant and/or Materials to bereplaced, and giving details of the due date of delivery tothe Site of the replacement item(s).
Where any item of Plant and/or Materials has become the propertyof the Employer under this Sub-Clause before it has been deliveredto the Site, the Contractor shall ensure that such an item is notmoved except for its delivery to the Site.
The Contractor shall indemnify and hold the Employer harmlessagainst and from the consequences of any defect in title orencumbrance or charge (except any reasonable restrictionarising from the intellectual property rights of the manufacturer orproducer) on any item of Plant and/or Materials that has becomethe property of the Employer under this Sub-Clause."
The following Sub-Clause7.9 is added after Sub Clause 7.8:

7.9    Use of Pakistani Materials and Services

The Contractor shall, so far as may be consistent with the Contract, make the maximum use of materials, supplies, plant and equipment indigenous to or produced or fabricated in Pakistan and services available in Pakistan provided such materials, supplies, plant, equipment and services shall be of required standard.

8.1    Commencement of Works

The following is added before the first paragraph:
“After signing of the Contract Agreement by both Parties,” and thereafter the word “The” is replaced with the word “the”.

8.5    Extension of Time for Completion

The following is added after paragraph (c):
“for last five years”.
The following Sub-Clause 8.14 is added after Sub-Clause 8.13:

8.14    Incentives For Early Completion

If Contract Data does not state applicability of incentives for early completion, this Sub-Clause shall not apply.
The Contractor shall be entitled subject to Sub-Clause 20.2 [Claims for Payment and/or EOT] to bonus payment if the Works and/or each Section is completed earlier than the Time for Completion for the Works or Section (as the case may be). The amount of bonus for early completion of the Works and/or each Section shall be upto a limit and at a rate to 50% of the relevant limit and rate of delay damages prescribed in Contract Data and shall be paid for every day which shall elapse between the relevant Date of Completion of the Works or Section and the relevant Time for Completion.
For the purposes of calculating any bonus payment, the applicableTime for Completion stated in the Contract Data is fixed and noadjustments of this time by reason of granting an EOT will beallowed.
The following Sub-Clause 11.12 is added after Sub-Clause 11.11:

11.12    Supervisory Assistance During DNP

If provided under the Schedule of Prices, the Contractor shall provide supervisory assistance to the Employer during the DNP for the Works. Such supervisory assistance shall be as described in the Specification for the purpose of supporting the Employer's operation and maintenance of the Plant for the period specified in the Schedule of Prices after the Date of Completion.

12.2    Method of Measurement

The following paragraph is added at the end of the Sub-Clause:
“Summary of measured quantity for payment shall be delineated item-wise under four headsnamely; “Schedule of Prices Quantity”, “Quantity Executed To-date”, “Quantity Certified Previously” and “Net Quantity Executed under this Certificate”.

12.3    Valuation of the Works

The following text is added at the end of fifth paragraph of the Sub-Clause:
“Sum of overhead charges and profit for sub-paragraph (a) shall be Twenty Five percent (25%)”.

13.4    Provisional Sums

The following paragraph is inserted as the penultimate paragraph:
“The Provisional Sum shall be used to cover the Employer’s share of the DAAB members’ fees and expenses, in accordance with Clause 21. No prior instruction of the Engineer shall be required with respect to the work of the DAAB. The Contractor shall submit the DAAB members’ invoices and the satisfactory evidence of having paid 100% of such invoices as part of the substantiation of those Statements submitted under Sub-Clause 14.3.

13.6    Adjustments for Changes in Laws

The following paragraphsare added at the end of the Sub-Clause:
“Notwithstanding the foregoing, the Contractor shall not be entitled to an extension of time if the relevant delay has already been taken into account in the determination of a previous extension of time and such Cost shall not be separately paid if the same shall already have been taken into account in the indexing of any inputs to the Table of Adjustment Data in accordance with the provisions of Sub-Clause 13.7 [Adjustments for Changes in Cost].”

14.1    The Contract Price

The following is added at the end of the Sub-Clause: 
“Notwithstanding the provisions of subparagraph (b), Contractor's Equipment, including essential spare parts, imported by the Contractor for the sole purpose of executing the Contract shall be temporarily exempt from the payment of import duties and taxes upon initial importation, provided the Contractor shall post with the customs authorities at the port of entry an approved re-export bond or bank guarantee, valid until the Time for Completion plus six months, in an amount equal to the full import duties and taxes which would be payable on the assessed imported value of such Contractor's Equipment and spare parts, and callable in the event the Contractor's Equipment is not re-exported from the Country on completion of the Contract. A copy of the bond or bank guarantee endorsed by the customs authorities shall be provided by the Contractor to the Employer upon the importation of individual items of Contractor's Equipment and spare parts. Upon re-export of individual items of Contractor's Equipment or spare parts, or upon the completion of the Contract, the Contractor shall prepare, for approval by the customs authorities, an assessment of the residual value of the Contractor's Equipment and spare part to be re-exported, based on the depreciation scale(s) and other criteria used by the customs authorities for such purposes under the provisions of the applicable Laws. Import duties and taxes shall be due and payable to the customs authorities by the Contractor on (a) the difference between the initial imported value and the residual value of the Contractor's Equipment and spare parts to re-exported; and (b) on the initial imported value of the Contractor's Equipment and spare parts remaining in the Country after completion of the Contract. Upon payment of such dues within 28 days of being invoiced, the bond or bank guarantee shall be reduced or released accordingly; otherwise the security shall be called in the full amount remaining.”
[The Employer may change or delete this Sub-Clause as per Project requirements]

14.2    Advance Payment

14.2.1    Advance Payment Guarantee
The entity issuing the Advance PaymentGuaranteeand its form shall be as under:
The Advance PaymentGuarantee shall be in the form of Guarantee issued by (a) a Scheduled Bank in Pakistan or (b) a foreign bank duly counter-guaranteed by a Scheduled Bank in Pakistanor (c)an Insurance Companylisted in the Contract Data and rated by PACRA/VIS ofrating as provided in Table below:
Accepted Contract Amount (In Eq. million PKR)    Minimum Rating of Insurance Companies
Up to 1000    A (+)
1001 to no limit    AA
In case of Joint Venture, the Advance PaymentGuarantee(s)shall be in the name of the Joint Venture or in the name of Lead/either firm of the JV or in ratio of shares of the individual JV partners.

14.6    Issue of IPC

14.6.1    The IPC
In the first line of the 1st paragraph the words “28 days” are substituted by “14 days”.

14.7    Payment

The words “or through crossed cheque in favour of the Contractor or JV partners. The Payment to JV partners shall be made at the request of the Joint Ventures in the ratio of their shares specified by them” are added at the end of the Sub-Clause.

14.8    Delayed Payment

In the first paragraph, third line, the words “compounded monthly” are deleted.
The text of 2nd paragraph is deleted and substituted with the following:
“The Employer shall pay to the Contractor compensation at the rate stated in the Contract Data.”

14.9    Release of Retention Money

The following is added at the end of Sub-Clause 14.9:
“Unless otherwise stated in the Contract, when the Taking-Over Certificate has been issued for the Works and the first half of the Retention Money has been certified for payment by the Engineer, the Contractor shall be entitled to substitute a guarantee, in the form annexed to the Particular Conditions or in another form approved by the Employer and issued by a schedule bank selected by the Contractor, for the second half of the Retention Money. The Contractor shall ensure that the guarantee is in the amounts and currencies of the second half of the Retention Money and is valid and enforceable until the Contractor has executed and completed the Works and remedied any defects, as specified for the Performance Security. On receipt by the Employer of the required guarantee, the Engineer shall certify, and the Employer shall pay the second half of the Retention Money. The release of the second half of the Retention Money against a guarantee shall then be in lieu of the release after the latest of the expiry dates of the Defects Notification Periods. The Employer shall return the guarantee to the Contractor within 21 days after receiving a copy of the Performance Certificate.

If the Performance Security required under Sub-Clause 4.2 is in the form of a demand guarantee, and the amount guaranteed under them when the Taking-Over Certificate is issued is more than half of the Retention Money, then the Retention Money guarantee will not be required. If the amount guaranteed under the Performance Security when the Taking-Over Certificate is issued is less than half of the Retention Money, the Retention Money guarantee will only be required for the difference between half of the Retention Money and the amount guaranteed under the Performance Security.

15.2    Termination for Contractor’s Default

15.2.1    Notice
Following text is added at the end of sub-paragraph (h) of this Sub-Clause:
“For the purposes of this Contract, corrupt and fraudulent practices have been defined in Public Procurement Rules 2004.”
15.2.3    After Termination
The word “and” at the end of sub-paragraph (ii) of paragraph (b) is deleted the following paragraph is added after sub-paragraph (iii):
“(iv)    all Employer-Supplied Materials and/or Employer's Equipment madeavailable to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer's Equipment], and”

15.4    Payment after Termination

The following text is added at the end of this Sub-Clause:
“The Employer shall be entitled to sell any of the Contractor’s Equipment, Temporary Works and unused materials and apply the proceeds of sale towards payment of any debt due from the Contractor to the Employer under this Clause including any outstanding payments to the Subcontractors.

16.2    Termination by Contractor

16.2.1    Notice
The sub-paragraph (j) is deleted in its entirety.
At the end of sub-paragraph (i) “; or” is replaced with “.” and at the end of sub-paragraph (h) “;” is replaced with “; or”.
In sub-paragraph (f) “84 days” are replaced with “180 days” and text “for reasons not attributable to the Contractor” is added at the end.

16.3    Contractor’s Obligations After Termination

Sub-paragraph (c) is deleted and replaced with:
"(c)    deliver to the Engineer all Employer-Supplied Materials and/orEmployer's Equipment made available to the Contractor in accordance with Sub-Clause 2.6 [Employer-Supplied Materials and Employer’s Equipment]; and
(d)    remove all other Goods from the Site, except as necessary for safety,and leave the Site."

17.1    Responsibility for Care of the Works

After the two instances of “Goods” in the last paragraph, the words “Employer-Supplied Materials and/orEmployer's Equipment” are added.
The following Sub-Clause 17.7 is added after Sub-Clause 17.6:

17.7    Use of Employer’s Accommodation/Facilities

The Contractor shall take full responsibility for the care of the items of the Employer’s facilities and/or accommodation, if any, as detailed in the Specification, from the date of use and/or occupation by the Contractor until the date on which such use and/or occupation is re-vested in the Employer.
If any loss or damage happens to any of the above items during a time while the Contractor is responsible for its care, arising from any cause other than a cause for which the Employer is responsible or liable, the Contractor shall promptly rectify the loss or damage at the Contractor’s risk and cost.

18.1    Exceptional Events

The words “or disorder” are replaced with “disorder or sabotage” in sub-paragraph (c) of the Clause.

18.4    Consequences of an Exceptional Event

The following is added at the end of sub-paragraph (b) after deleting the “.”: 
“, including the costs of rectifying or replacing the Works and/or Goods damaged or destroyed by Exceptional Events, to the extent they are not indemnified through the insurance policy referred to in Sub-Clause 19.2 [Insurance to be provided by the Contractor].”

18.5    Optional Termination

In sub-paragraph (c), the words “and necessarily” areadded after the words “was reasonably”.

19.1    General Requirements

Following text is added at the end of first paragraph:
“The Contractor shall immediately after the date of the Letter of Acceptance submit the draft of insurance policies for the Employer’s consent.”
Following text is added at the end of third paragraph:
“The Contractor shall, within the respective periods stated in the Contract Data submit to the Engineer and the Employer a) evidence that the insurances described in this Clause have been effected, and b) copies of policies of the insurances described in Sub-Clauses 19.2.1, 19.2.4 and 19.2.5.”

19.2    Insurance to be provided by the Contractor   

19.2.5    Injury to employees
The words “sickness, disease” are deleted in the third line of first paragraph.

The following Sub-Clause is added after Sub-Clause 19.2.6:
19.2.7    Insurance Company
“The Contractor shall be obliged to place all insurances described in this Clause with insurers listed in the Contract Data and rated byPACRA/VISofrating as provided in Table below:

Accepted Contract Amount (In Eq. million PKR)    Minimum Rating of Insurance Companies
Up to 1000    A (+)
1001 to no limit    AA

21.6    Arbitration

    The word “international” is deleted in the sixth line of first paragraph. The text of sub-paragraph (a) is substituted with the following:
“the Dispute shall be finally settled under the Rules of Arbitration, specified in the Contract Data;”
The following Clauses are added after Clause 21

22    Custom Duty   

[Employer may incorporate provisions where applicable. However, in order to make the bid more balanced, the payment of Customs Duties should be the responsibility of the Employer.]

23    Taxes   

The Contractor, Subcontractors and their employees shall be liable to pay income tax, withholding tax, super tax and other taxes on income arising out of the Contract. The rates and prices as stated in the contract shall be deemed to cover all such taxes.

24    Integrity Part

If it is found and established at any stage that the Contractor or any of his Subcontractors, agents or servants have violated or involved in violation of the Integrity Pact signed by the Contractor then the Employer shall be entitled to :
(a)    recover from the Contractor an amount equivalent to ten times the sum of any commission, gratification, bribe, finder’s fee or kickback given by the Contractor or any of his Subcontractors, agent or servants;
(b)    terminate the Contract; and
(c)    recover from the Contractor any loss or damage to the Employer as a result of such termination or of any other corrupt business practices of the Contractor or any of his Subcontractors, agent or servants. 
The termination under sub-paragraph(b) of this Sub-Clause shall proceed in the manner prescribed under Sub-Clause 15.1 to 15.4 and the payment under Sub-Clause 15.4 shall be made after having deducted the amounts due to the Employer under sub-paragraph(a) and (c) of this Sub-Clause.
Appendix     General Conditions of Dispute Avoidance/Adjudication Agreement

12    Disputes Under DAAB Agreement

In the first paragraph, third, fourth and fifth line, the text “under the Rules of Arbitration of the International Chamber of Commerce 2017……………shall apply” is substituted with “under the Arbitration Act 1940 by sole arbitrator appointed by the Managing Director Public Procurement Regulatory Authority or Chairman Pakistan Engineering Council.”

 

 

 

 

📑 Bid Securing Declaration (BSD)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

FORM OF BID SECURING DECLARATION

Date: 
No.: 
Alternative No.: P63434

To: Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad

We, the undersigned, declare that:

We understand that, according to your conditions, Bids must be supported by a Bid-Securing Declaration.

We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:

(a)     have withdrawn our Bid during the period of Bid validity specified in the Letter of Bid; or
(b)     having been notified of the acceptance of our Bid by the Procuring agency/Employer during the period of Bid validity, (i) fail or refuse to sign the Contract; or (ii) fail or refuse to furnish the Performance Security (or guarantee), if required, in accordance with the ITB.

We understand this Bid Securing Declaration shall expire if we are not the successful Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight days after the expiration of our Bid.

 

Name of the Bidder*    
Name of the person duly authorized to sign the Bid on behalf of the Bidder**    _______
Title of the person signing the Bid    ______________________
Signature of the person named above    ______________________
Date signed ________________________________ day of ___________________, _____
*: In the case of the Bid submitted by joint venture specify the name of the Joint Venture as Bidder
**: Person signing the Bid shall have the power of attorney given by the Bidder attached to the Bid

[Note: In case of a Joint Venture, the Bid-Securing Declaration must be in the name of all members to the Joint Venture that submits the Bid.]

📑 Contract Form (CNF)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

FORM OF CONTRACT AGREEMENT

THIS CONTRACT AGREEMENT (hereinafter called the “Agreement”) made on the _________ day of __________ (month) 20_____ between Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad (hereinafter called the “Employer”) of the one part and __________________________________________________ (hereinafter called the “Contractor”) of the other part.
WHEREAS the Employer is desirous that certain Works, viz., WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD. (P63434) should be executed by the Contractor and has accepted a Bid by the Contractor for the execution and completion of such Works and the remedying of any defects therein.
NOW this Agreement witnessed as follows:
1.    In this Agreement words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract hereinafter referred to.
2.    The following documents, in the order of priority, after incorporating addenda, if any, except those parts relating to Instructions to Bidders shall be deemed to form and be read and construed as part of this Agreement:
a)    This Contract Agreement;
b)    The Letter of Acceptance;
c)    The Letter of Bid;
d)    The Particular Conditions Part A - Contract Data;
e)    The Particular Conditions Part B - SpecialProvisions;
f)    The General Conditions;
g)    The Specifications Part A - SpecificProvisions;
h)    The Specifications Part B- Technical Provisions;
i)    The Drawings;
j)    The Completed Schedules to Bid including Schedule of Prices;
k)    the JV Undertaking (if the Contractor is a JV); and
l)    [Employer to insert any other documents forming part of the Contract]

The addenda/corrigenda,if any, (Excluding part relating to Instructions to Bidders alongwith Bidding Data) shall be deemed to have been incorporated at the appropriate places in the “Documents forming the Contract”.
3.    In consideration of the payments to be made by the Employer to the Contractor as hereinafter mentioned, the Contractor hereby covenants with the Employer to execute and complete the Works and remedy defects therein in conformity and in all respects with the provisions of the Contract.
4.    The Employer hereby covenants to pay the Contractor, in consideration of the execution and completion of the Works as per provisions of the Contract, the Contract Price or such other sum as may become payable under the provisions of the Contract at the times and in the manner prescribed by the Contract.


IN WITNESS WHEREOF the parties hereto have caused this Agreement to be executed on the day, month and year first before written in accordance with their respective laws.

 

Signature of the Contactor        Signature of Employer
        
(Seal)        (Seal)
Signed, Sealed and Delivered in the presence of:

Witness        Witness
        
        
(Name, Title and Address)        (Name, Title and Address)

 

DAAB Agreement

[All italicised text and any text within square brackets (except sub-clause headings) in this form of agreement is for use in preparing the form and should be deleted from the final product].

Name and details of the Contract WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.
______________________________________________________________________________

This Agreement made the ______day of ______ [month], _____ [year], between

Name and contact details of the Employer  Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA    
   Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad
   +92-334-856-6622
   ammarpavero@gmail.com


Name and contact details of the Contractor     _____________________________________ (name)
    ____________________________________ (address)
    __________________________________ (telephone)
    ___________________(email / other contact details);

Name and contact details of the DAAB Member    _____________________________________ (name)
    ____________________________________ (address)
    __________________________________ (telephone)
    ___________________(email / other contact details);


(“DAAB Agreement”)

Whereas:
A.    the Employer and the Contractor have entered (or intend to enter) into the Contract;
B.    under the Contract, the “DAAB” or “Dispute Avoidance/Adjudication Board” means the sole member or three members (as stated in the Contract Data of the Contract) so named in the Contract, or appointed under Sub-Clause 21.1 [Constitution of the DAAB] or Sub-Clause 21.2 [Failure to Appoint DAAB Members] of the Conditions of Contract;
C.    the Employer and the Contractor desire jointly to appoint the above-named DAAB Member to act on the DAAB as:
a.    the sole member of the DAAB, and where this is the case, all references to the “Other Members” do not apply; or
b.    one of three members / chairman [delete the one which is not applicable] of the DAAB and, where this is the case, the other two persons are:

 

____________________________ (name)    _________________________ (name)
___________________________ (address)    _______________________ (address)
_____________________________(telephone)    ______________________(telephone)
______________(email/ other contact details)    _______ (email/other contact details)

the “Other Members”; and
D.    the DAAB Member accepts this appointment.

The Employer, Contractor and DAAB Member jointly agree as follows:

1.    The conditions of this DAAB Agreement comprise:
(a)    Clause 21 [Disputes and Arbitration] of the Conditions of Contract, and any other provisions of the Contract that are applicable to the DAAB’s Activities; and
(b)    the “General Conditions of Dispute Avoidance/Adjudication Agreement”, which is appended to the General Conditions of the “Conditions of Contract for Construction” Second Edition 2017 published by FIDIC (“GCs”), as amended and/or added to by the following provisions.
2.    [Details of amendments to the GCs, if any. For example:
In the procedural rules annexed to the GCs, Rule _ is deleted and replaced by: “ … “]
3.    The DAAB Member shall be paid in accordance with Clause 9 of the GCs. The currency of payment shall be ________.
In respect of Sub-Clauses 9.1 and 9.2 of the GCs, the amounts of the DAAB Member’s monthly fee and daily fee shall be:
monthly fee___________________ per month, and
daily fee of____________________ per day
(or as otherwise set under Sub-Clause 9.3 of the GCs).
4.    In consideration of the above fees, and other payments to be made to the DAAB Member in accordance with the GCs, the DAAB Member undertakes to act as DAAB Member in accordance with the terms of this DAAB Agreement.
5.    The Employer and the Contractor shall be jointly and severally liable for the DAAB Member’s fees and other payments to be made to the DAAB Member in accordance with the GCs.
6.    This DAAB Agreement shall be governed by the law of _____________ (if not stated, the law that governs the Contract under Sub-Clause 1.4 of the Conditions of Contract).

SIGNED by:_______________    SIGNED by:_______________    SIGNED by:_______________
Print name:_________________    Print name:_________________    DAAB Member
Title: _____________________    Title:______________________    Title:______________________
for and on behalf of the
Employer    for and on behalf of the
Contractor    
in the presence of    in the presence of    in the presence of
Witness:___________________    Witness:___________________    Witness:___________________
Name:_____________________    Name:_____________________    Name:_____________________
Address:___________________    Address:___________________    Address:___________________
__________________________    __________________________    __________________________
Date:______________________    Date:______________________    Date:______________________

 

FORM OF MOBILIZATION ADVANCE GUARANTEE/ BOND

Guarantee No._________________________________________ Date _________________


WHEREAS _____________________________________ (hereinafter called the 'Employer')
has entered into a Contract for __________________________________________________
(Particulars of Contract)
with ____________________________________________ (hereinafter called the "Contractor').
AND WHEREAS, the Employer has agreed to advance to the Contractor, at the Contractor's request, an amount of Pak Rupees ___________________________________ (PKR _________ ) which amount shall be advanced to the Contractor as per provisions of the Contract.
AND WHEREAS, the Employer has asked the Contractor to furnish Guarantee to secure the mobilization advance for the performance of his obligations under the said Contract.
AND WHEREAS, ____________________________________________________________

(hereinafter called the “Guarantor”) at the request of the Contractor and in consideration of theEmployer agreeing to make the above advance to the Contractor, has agreed to furnish the said Guarantee.
NOW, THEREFORE, the Guarantor hereby guarantees that the Contractor shall use the advance for the purpose of above mentioned Contract and if he fails and commits default in fulfilment of any of his obligations for which the advance payment is made, the Guarantor shall be liable to the Employer for payment not exceeding the aforementioned amount.
Notice in writing of any default,on the part of the Contractor, of which the Employer at his discretion of making decision, shall be given by the Employer to the Guarantor, and on such first written demand, payment shall be made by the Guarantor of all sums then due under this Guarantee without any reference to the Contractor and without any objection.
This Guarantee shall remain in force until the advance is fully adjusted against payments from the Interim Payment Certificates of the Contractor or until _________________________whichever is earlier.                                    (Date)
The Guarantor's liability under this Guarantee shall not in any case exceed the sum of 
PKR ______________________ (PakRupees ________________________________________________).
This Guarantee shall remain valid up to the aforesaid date and shall be null and void after the aforesaid date or earlier if the advance made to the Contractor is fully adjusted against paymentsfrom Interim Payment Certificates of the Contractor provided that the Guarantor

agrees that the aforesaid period of validity shall be deemed to be extended if on the above mentioned date the advance payment is not fully adjusted.

 

Guarantor
(Scheduled Bank/ Insurance Company)

Signature ________________________________________________
Name ________________________________________________
Title ________________________________________________ 

 

WITNESS:                        

           

1.     ________________________________________________
       ________________________________________________                             
       Corporate Secretary (Seal)     Corporate Guarantor (Seal)

2.    ________________________________________________
       ________________________________________________              
       Name, Title & Address

 

 

Retention Money Security
Demand Guarantee

________________________________ [Guarantor letterhead or SWIFT identifier code]
Beneficiary:    ___________________ [Insert name and Address of Employer]        
Date:    ________________[Insert date of issue]
RETENTION MONEY GUARANTEE No.:    [Insert guarantee reference number]
Guarantor:  [Insert name and address of place of issue, unless indicated in the letterhead]

We have been informed that ________________ [insert name of Contractor, which in the case of a joint venture shall be the name of the joint venture] (hereinafter called "the Contractor") has entered into Contract No. _____________ [insert reference number of the contract] dated ____________ with the Employer, for the execution of _____________________ [insert name of contract and brief description of Works] (hereinafter called "the Contract"). 
Furthermore, we understand that, according to the conditions of the Contract, the Employer retains moneys up to the limit set forth in the Contract (“the Retention Money”), and that when the Taking-Over Certificate has been issued under the Contract and the first half of the Retention Money has been certified for payment, payment of [insert the second half of the Retention Money orifthe amount guaranteed under the Performance Guarantee when the Taking-Over Certificate is issued is less than half of the Retention Money, the difference between half of the Retention Money and the amount guaranteed under the Performance Security and, if required, the ES Performance Security] is to be made against a Retention Money guarantee.
At the request of the Applicant, we, as Guarantor, hereby irrevocably undertake to pay the Beneficiary any sum or sums not exceeding in total an amount of ___________ [insert amount in figures] () [amount in words] upon receipt by us of the Employer’s complying demand supported by the Beneficiary’s statement, whether in the demand itself or in a separate signed document accompanying or identifying the demand,  stating that the Applicant is in breach of its obligation(s) under the Contract, without your needing to prove or show grounds for your demand or the sum specified therein. 
A demand under this guarantee may be presented as from the presentation to the Guarantor of a certificate from the Employer’s bank stating that the second half of the Retention Money as referred to above has been credited to the contractor on its account number ___________ at _________________ [insert name and address of Contractor’s bank].
This guarantee shall expire no later than the …. day of ……, 2…, and any demand for payment under it must be received by us at the office indicated above on or before that date.

____________________     
[signature(s)]

Note:  All italicized text (including footnotes) is for use in preparing this form and shall be deleted from the final product.

 

 

 

📑 Integrity Pact (INP)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

Integrity Pact

DECLARATION OF FEES, COMMISSION AND BROKERAGE ETC. PAYABLE BYTHE SUPPLIERS OF GOODS, SERVICES & WORKS IN  CONTRACTS WORTH RS.10.00 MILLION OR MORE

 

Contract                           Number:  Contract                               Value:  Contract Title:

Dated:

 

[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.

Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid  or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.

[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.

[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.

Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.

 

Name of Employer: ………………                                           Name of Bidder/Contractor: ……………
Signature: ……………………                                                   Signature: …………………………….
[Seal]                                                                                   [Seal]

📑 Performance Guarantee Form (PGF)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

FORM OF PERFORMANCE SECURITY

Guarantee No.___________________
Executed on ____________________
Expiry date _____________________


Name of Guarantor with address: _________________________________________________________________________________________________________________________________

Name of Principal (Contractor) with address:___________________________________________________________________________________________________________________________

Penal Sum of Security (express in words and figures) ____________________________________________________________________________________________________________________

Letter of Acceptance No. _____________________________________Dated __________________

KNOW ALL MEN BY THESE PRESENTS, that in pursuance of the terms of the Bidding Documents and above said Letter of Acceptance (hereinafter called the Documents) and at the request of the said Principal we, the Guarantor above named, are held and firmly bound unto the Capital Development Authority (Works Directorate), Dy. Director (Works-II), CDA Office # 26, 1st Floor, Block-III, CDA Secretariat, G-7/4, Islamabad (hereinafter called the Employer) in the penal sum of the amount stated above for the payment of which sum well and truly to be made to the said Employer, we bind ourselves, our heirs, executors, administrators and successors, jointly and severally, firmly by these presents.

THE CONDITION OF THIS OBLIGATION IS SUCH, that whereas the Principal has accepted the Employer's above said Letter of Acceptance for _____________________________________ ________________________________

(Name of Contract) for the WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD. (P63434)
______________________________________________ (Name of Project).

NOW THEREFORE, if the Principal (Contractor) shall well and truly perform and fulfill all the undertakings, covenants, terms and conditions of the said Documents during the original terms of the said Documents and any extensions thereof that may be granted by the Employer, with or without notice to the Guarantor, which notice is, hereby, waived and shall also well and truly perform and fulfill all the undertakings, covenants terms and conditions of the Contract and of any and all modifications of said Documents that may hereafter be made, notice of which modifications to the Guarantor being hereby waived, then, this obligation to be void; otherwise to remain in full force and virtue till all requirements of Clause11, Defects After Taking Over, of Conditions of Contract are fulfilled.

Our total liability under this Guarantee is limited to the sum stated above and it is a condition of any liability attaching to us under this Guarantee that the claim for payment in writing shall be received by us within the validity period of this Guarantee, failing which we shall be discharged of our liability, if any, under this Guarantee.

We, _________________________________________________ (the Guarantor), waiving all objections and defense under the Contract, do hereby irrevocably and independently guarantee to pay to the Employer without delay upon the Employer's first written demand without cavil or arguments and without requiring the Employer to prove or to show grounds or reasons for such demand any sum or sums up to the amount stated above, against the  Employer's written declaration that the Principal has refused or failed to perform the obligations under the Contract which payment will be effected by the Guarantor to Employer’s designated Bank & Account Number.

PROVIDED ALSO THAT the Employer shall decide, whether the Principal (Contractor) has duly performed his obligations under the Contract or has defaulted in fulfilling said obligations and the Guarantor shall pay without objection any sum or sums up to the amount stated above upon first written demand from the Employer forthwith and without any reference to the Principal or any other person.

IN WITNESS WHEREOF, the above-bounden Guarantor has executed this Instrument under its seal on the date indicated above, the name and corporate seal of the Guarantor being hereto affixed and these presents duly signed by its undersigned representative, pursuant to authority of its governing body.

 

Guarantor
(Schedule Bank/ Insurance Company)
Signature:  _________________________________________________
Name: _________________________________________________
Title: _________________________________________________ 

Corporate Guarantor (Seal)

 

    
WITNESS:                 

1.
_________________________________________________ 
_________________________________________________  

2.  

_________________________________________________ 
_________________________________________________ 
Name, Title & Address

📑 Annexure (ANX)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

Abstart of Cost

The bidder is required to submit Abstract of Cost.

Unknown

Document Required

Complete BOQ

Complete BOQ in pdf format

Unknown

📑 Procurement Forms (PFD)

WELLNESS COMPLEX MINISTER'S ENCLAVE, ISLAMABAD.

Published on: Thursday, July 16, 2026 10:58 PM

Ref# : P63434
QR Code

Past Construction Experiences

Contractor's Key Personnel Representative and Their Schedules

Financial Resources

Past Experience and Completed Contracts

Historical Contract Non-Performance, and Pending Litigation and Litigation History

Current Contracts and Their Progress

Financial Capacity and Net Worth Evaluation Form

Average Annual Turnover