In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director
Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
+92-315-983-2148
muhammadsuleman@paa.gov.pk
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)) The subject of procurement is: CONSTRUCTION OF 32 NO. JS APARTMENTS (02 BED) FOR ASF AT IIAP ISLAMABAD. Expected commencement date: Monday, September 7, 2026 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P71351 |
| 3. | 3.1 | JV/Consortium or Association Allowed: Yes Number of JV/Consortium Members: 02 |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Thursday, August 6, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid:
|
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 120 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Banker's Cheque |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Thursday, August 13, 2026 11:00 AM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Thursday Date: August 13, 2026 Time : 11:30 AM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 5.00%. The Performance Guarantee shall be acceptable in the form of: Bank Guarantee |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Sole Proprietorship Company (Private Limited) State Owned Enterprise (Private Limited) | NADRA CITIZENSHIP (CNIC/NICOP) FBR (NTN) SECP PEC |
Least Cost Based Selection (LCBS)
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| CONSTRUCTION OF 32 NO. JS APARTMENTS (02 BED) FOR ASF AT IIAP ISLAMABAD | Address: Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory Schedule: 365 Days Quantity: 1/job |
1/job | 9000000 PKR |
No
Jobs Without Lots :
Job: CONSTRUCTION OF 32 NO. JS APARTMENTS (02 BED) FOR ASF AT IIAP ISLAMABAD
Specifications / Requirements:
| Sr. No | Item Ref.No | Description | Unit | Qty | RATE | Amount | |
|---|---|---|---|---|---|---|---|
| 1 | In Figure | In Words | |||||
| 2 | 1 | Cutting to a required gradient in all kinds of soil (except rock) and dressing the ground by bulldozers, grader or scraper including disposal of excavated stuff within 3 chains (91.5 Rm) including all lifts as required. | 100 Cft | 7200 | |||
| 3 | 2 | Excavation for foundation trenches and drains in all kinds of soil (except gravelly and murum soil, wet silt, clay or mud conglomeration of gravel and boulders, soft, sandy or disintegrated sandy and hard rock) and back filling the excavated material in foundation, plinth or under floor including breaking clods, watering, consolidation by ramming in layers not exceeding 9 inches (229 mm) in depth to full compaction, dressing and disposal of surplus excavated stuff as directed, lead upto one chain (30.5 R.m) and lift upto 5 feet (1.52 m). | 100 Cft | 39690 | |||
| 4 | 3 | Supplying and laying machine crushed 2" to 1/2" (51 mm to 13 mm) stone ballast of approved grade and quality in sub-base or base courses in required grade and camber and compacting to the required density by approved mechanical means (Vibratory Roller, Road Packer and Smooth Wheel Roller etc.) including watering with all lead and lift complete. (actual compacted depth shall be considered for payment) | 100 Cft | 7938 | |||
| 5 | 4 | Providing and carrying out termite proffing in foundations, under floors and wood work surface with a solution using of confront TC with water and spraying the solution of the area to be treated as completed as per direction of Engineer incharge. | P.Sft | 9600 | |||
| 6 | 5 | Providing and laying 1:4:8 (1 cement 4 sand and 8 coarse aggregate) cement concrete using crushed graded boulders (machine broken) 1 inches (51 mm) and down gauge in foundation including levelling, compacting and curing etc. complete. | 100 Cft | 1984 | |||
| 7 | 6 | P/L RCC using crushed graded boulders 3/4" & down gauge with lawrencepur sand having min.works cube crushing strength of 3750 PSI at 28 days with a mix not leaner than 1:1-1/2:3 i/c form work & its removal compacting & curing etc. complete but excluding the cost of steel reinforcement... | |||||
| 8 | i | In column Raft foundation of required size. | 100 Cft | 12916 | |||
| 9 | ii | In footing column in foundation basement and plinth. | 100 Cft | 244 | |||
| 10 | iii | In plinth beams of required shape and design in foundation basement and plinth. | 100 Cft | 1316 | |||
| 11 | iv | In columns of square or rectangular shape in G/floor superstructure. | 100 Cft | 1296 | |||
| 12 | v | In straight beams, cantilever beams of required shape/section in basement and ground floot. | 100 Cft | 1360 | |||
| 13 | vi | In ordinary slab 5" to 6" thick in basement, plinth and ground floor. | 100 Cft | 3200 | |||
| 14 | vii | In ordinary slab more than 6" thick in basement, plinth and ground floor. | 100 Cft | 126 | |||
| 15 | viii | In straight stairs and landing G/F | 100 Cft | 80 | |||
| 16 | ix | In lintels of required size in G/floor. | 100 Cft | 386 | |||
| 17 | x | In shelves 1-1/2" to 2" thick in ground floor. | 100 Cft | 26 | |||
| 18 | xi | In columns of square or rectangular shape in 1st floor | 100 Cft | 1296 | |||
| 19 | xii | In straight beams, cantilever beams of required shape/section in 1st floor | 100 Cft | 1466 | |||
| 20 | xiii | In ordinary slab 5" to 6" thick in 1st floor. | 100 Cft | 3204 | |||
| 21 | xiv | in cantilever chajja F/F | 100 Cft | 126 | |||
| 22 | xv | In straight stairs and landing .F/F | 100 Cft | 80 | |||
| 23 | xvi | In lintels of required size in 1st floor. | 100 Cft | 226 | |||
| 24 | xvii | In shelves 1-1/2" to 2" thick 1st Floor. | 100 Cft | 26 | |||
| 25 | xviii | In columns of square or rectangular shape in 2nd floor | 100 Cft | 1296 | |||
| 26 | xix | In straight beams, cantilever beams of required shape/section in 2nd floor | 100 Cft | 1466 | |||
| 27 | xx | In ordinary slab 5" to 6" thick in 2nd floor. | 100 Cft | 3204 | |||
| 28 | xxi | in cantilever chajja 2nd/F | 100 Cft | 126 | |||
| 29 | xxii | In straight stairs and landing .2nd/F | 100 Cft | 80 | |||
| 30 | xxiii | In lintels of required size in 2nd floor. | 100 Cft | 226 | |||
| 31 | xxiv | In ordinary slab 3" to 5" thick in 2nd floor. | 100 Cft | 26 | |||
| 32 | xxv | In columns of square or rectangular shape in 3rd floor | 100 Cft | 1322 | |||
| 33 | xxvi | In straight beams, cantilever beams of required shape/section in 3rd floor | 100 Cft | 1466 | |||
| 34 | xxvii | In ordinary slab 5" to 6" thick in 3rd floor. | 100 Cft | 3204 | |||
| 35 | xxviii | in cantilever chajja 3rd/F | 100 Cft | 126 | |||
| 36 | xxix | In ordinary slab 3" to 5" thick in 3rd floor. | 100 Cft | 80 | |||
| 37 | xxx | In over head water tank, beams, etc in 3rd Floor | 100 Cft | 226 | |||
| 38 | xxxi | In ordinary slab 3" to 5" thick in 3rd floor. | 100 Cft | 26 | |||
| 39 | xxxii | In columns of square or rectangular shape in 3rd floor Mumty. | 100 Cft | 68 | |||
| 40 | xxxiii | In straight beams, cantilever beams of required shape/section in 3rd floor Mumty. | 100 Cft | 124 | |||
| 41 | xxxiv | In ordinary slab 3" to 5" thick in 3rd floor Mumty. | 100 Cft | 240 | |||
| 42 | xxvi | In a square of rectangular bottom slab of over head water tankin 3rd Floor. | 100 Cft | 600 | |||
| 43 | 8 | Providing and fixing plain polyvinyle chloride (PVC) water stops 12" (305 mm) wide in vertical or horizontal expansion joints including cutting and jointing etc. complete in all floors. | P.Rft | 90 | |||
| 44 | 9 | Providing and mixing water proofing agent cemcon in cement mortar of any description in any floor @ 0.25ltr/Bag. | P.Ltr | 28 | |||
| 45 | 10 | Providing and laying dado and skirting etc. 7/8 inch (22 mm) thick consisting of 3/8 inch (9.5 mm) thick topping 1:2 (one grey cement 2 marble chips 0 to 4 No.) in 2nd floor over 1/2 inch (13 mm) thick cement mortar base 1:4 with grinding, rubbing, polishing and curing etc. complete. | 100 Sft | 556 | |||
| 46 | 11 | Providing and laying hard grade ribbed deformed (minimum yield point 60,000 psi) reinforcement bars with & including the cost of straightening, cutting, bending, binding, wastage, and such overlaps as are not shown in the drawings, placing in position on cement concrete 1:2:4 precast or m.s. chairs, tying with binding wire, cost of chairs and wires etc. in all kinds of RCC work in foundation, basement, plinth and ground floor of building including septic tanks and under ground tanks and in projections for future extension . | P.Kg | 158892.92196007 | |||
| 47 | 12 | P/L 1st class solid burnt brick masonry in straight or curved walls set in cement mortar i/c racking out joints scaffoldings & curing etc. complete as directed: | |||||
| 48 | ii | ii)-----do------ 9" to 13-/2 inches thick complete in foundation, basement and plinth CM 1:6 | 100 Cft | 2412 | |||
| 49 | iii | iii)-----do------ 9" to 13-1/2" thick in G/floor superstructure in CM 1:6 | 100 Cft | 7680 | |||
| 50 | 13 | iv)-----do------ 9" to 13-1/2" thick in 1st floor superstructure in CM 1:6 | 100 Cft | 7680 | |||
| 51 | 14 | v)-----do------ 9" to 13-1/2" thick in 2nd floor superstructure in CM 1:6 | 100 Cft | 6960 | |||
| 52 | 15 | v)-----do------ 9" to 13-1/2" thick in 3rd floor superstructure in CM 1:6 | 100 Cft | 7680 | |||
| 53 | 16 | v)-----do------ 9" to 13-1/2" thick in 4th floor superstructure in CM 1:6 | 100 Cft | 766 | |||
| 54 | 17 | vi) 4-1/2" or less in thickness in G/floor in CM 1:4 | 100 Cft | 1114 | |||
| 55 | i | vii)-----do------ 4-1/2" or less thickness in 1st floor in CM 1:4 | 100 Cft | 1114 | |||
| 56 | ii | vii)-----do------ 4-1/2" or less thickness in 2nd floor in CM 1:4 | 100 Cft | 1114 | |||
| 57 | iii | vii)-----do------ 4-1/2" or less thickness in 3rd floor in CM 1:4 | 100 Cft | 1114 | |||
| 58 | 18 | P/F of Dowel pin bar 1/4" dia 1'-0" long up to 3" in the column and 9" in wall @3'- 0" centre to centre i/c the cost of drilling in the coulmn complete as per direction of Engineer-in-Charge | P.Rft | 2304 | |||
| 59 | 19 | Providing and fixing M.S. moulded steel door frames manufactured from mild steel sheet of 18 gauge (1.41 mm) conforming to B.S.S. 1245, provision of 3 Nos. M.S. plate, section 1-1/2" x 1/4" (38 mm x 6 mm) (2 Nos. 6 inch long welded with frame at not less than 10 points and 1 Nos. 12 inch long welded with frame at not less than 20 points), with holes and threads for fixing steel hinges, fitted with one locking box of same sheet (point welded inside the frame), 6 Nos. 6 inches long flat iron fixing lugs of 1-1/4" x 3/16" section, treated with special red oxide primer coat all around including cutting holes and filling the cavity with cement concrete 1:2:4 etc. in any floor at any height complete as directed by the Engineer-in-Charge. | |||||
| 60 | i | (i) of 5.73" x 2-1/2" having a single/double rebate size 1-1/2" x 1/2". | P.Rft | 2112 | |||
| 61 | ii | (ii) of 10" x 2-1/2" having a double rebate size 1-1/2" x 1/2". | P.Rft | 4852 | |||
| 62 | 20 | 1/4" (6.4 mm) thick cement plaster 1:3 on soffits of ceiling, cantilever slabs, sides and soffits of beams etc., in basement, mezzanine and ground floor including making edges, corners and curing etc., complete | 100 Sft | 6752 | |||
| 63 | i | Do but in first floor | 100 Sft | 6752 | |||
| 64 | ii | Do but in 2nd floor | 100 Sft | 6752 | |||
| 65 | iii | Do but in 3rd floor | 100 Sft | 6752 | |||
| 66 | iv | Do but in 4th floor | 100 Sft | 1584 | |||
| 67 | 21 | 1/2" (13 mm) thick cement plaster 1:6 on walls and columns etc. in basement, plinth, mezzanine and ground floor including making edges, comers, and curing etc., complete. | 100 Sft | 13400 | |||
| 68 | i | Do but in first floor | 100 Sft | 13400 | |||
| 69 | ii | Do but in 2nd floor | 100 Sft | 13400 | |||
| 70 | ii | Do but in 3rd floor | 100 Sft | 13400 | |||
| 71 | ii | Do but in 4th floor | 100 Sft | 1496 | |||
| 72 | 22 | 3/4" (13 mm) thick cement plaster 1:4 on walls and columns etc. in basement, plinth, mezzanine and ground floor including making edges, comers, and curing etc, complete. | 100 Sft | 5904 | |||
| 73 | ii | Do but in first floor | 100 Sft | 5904 | |||
| 74 | iii | Do but in 2nd floor | 100 Sft | 5904 | |||
| 75 | iv | Do but in 3rd floor | 100 Sft | 5904 | |||
| 76 | v | Do but in 4th floor | 100 Sft | 1496 | |||
| 77 | 23 | Providing and laying 1:4:8 cement concrete bed under floors using graded stone ballast 1 inches and down gauge with levelling and ramming, watering and curing etc. complete. | 100 Cft | 10470 | |||
| 78 | 24 | Providing and laying 1:4:8 cement concrete bed under floors using graded stone ballast 1 inches and down gauge in FF with levelling and ramming, watering and curing etc. complete. | 100 Cft | 1988 | |||
| 79 | 25 | Providing and laying 1:4:8 cement concrete bed under floors using graded stone ballast 1 inches and down gauge in 2nd floor with levelling and ramming, watering and curing etc. complete. | 100 Cft | 1988 | |||
| 80 | 26 | Providing and laying 1:4:8 cement concrete bed under floors using graded stone ballast 1 inches and down gauge in 3rd floor with levelling and ramming, watering and curing etc. complete. | 100 Cft | 1988 | |||
| 81 | 27 | Providing and laying light colour, glazed/non skid vitrified porcelean tiles (Polished) exceeding 1600 Sqcm and upto 3600 Sqcm each, (Pak made) on walls and floors, in any floor, laid with dry bond (stile bond) over a base of 1" thick cement mortar (1:3) including jointing to tiles with joint filler of approved quality as per direction of the Engineer incharge. | 100 Sft | 30310 | |||
| 82 | 28 | Providing and fixing 10mm thick first grade Pakistani glazed tiles of National on facing of approved size colour/shade on walls, columns and pillers etc in ground floor over 1/2" (13mm) thick base of cement motar 1:3 setting of tiles in slurry of grey cement over mortar base, including filling the joint and washing the tiles with cement slurry of matching colour, (by using white cement mixed with pigment) curing and cleaning etc. complete as per direction of the engineer-in-charge. | 100 Sft | 3028 | |||
| 83 | 29 | Providing and laying floor of 1 inch (25 mm) thick Granite marble tiles of Pakistani origin, fine dressed on the surface without winding in ground floor over 1 inch (25 mm) cement mortar 1:4 (one cement, four sand) setting the marble tiles with grey cement slurry over cement mortar, jointing and washing the tiles with white cement slurry including curing, rubbing and polishing etc. complete including the cost of mortar. | |||||
| 84 | i | more than 3 Sq.ft. upto 5 Sq.ft for stair/steps(in treads, risers and midstair landings) G/F. | 100 Sft | 704 | |||
| 85 | ii | more than 5 Sq.ft. upto 7 Sq.ft for stair/steps(in treads, risers and midstair landings) G/F. | 100 Sft | 640 | |||
| 86 | iii | Extra for making nosing of treads as per design and instructions of the Engineer-in-Charge. | P.Rft | 1056 | |||
| 87 | iv | Making Grooves in Stair Trades (anti skid Grooves) complete as per direction of Engineer Incharge | P.Rft | 2208 | |||
| 88 | 30 | Providing and fixing 1-1/2 inch (38 mm) thick best quality deodar wood shutters fully panelled with same wood, approved iron hinges and tower bolts, etc., as required.. | P.Sft | 4864 | |||
| 89 | 31 | Providing and fixing approved heavy type iron handles 5" (127 mm) size with necessary iron screws. | Each | 226 | |||
| 90 | 32 | Providing and fixing approved heavy type iron sliding or aldrope bolts 6" x 1/2" (152 mm x 13 mm) size with necessary iron screws, iron bolts and nuts . | Each | 226 | |||
| 91 | 33 | Providing and fixing with C.P. brass screws main door handle type yale lock (Italy make) of approved design, cutting wood etc., to required size, with two operating keys, as per direction of the engineer-in-Charge. | Each | 226 | |||
| 92 | 34 | Providing and fixing with brass screws lucky / KGI Latch lock set of approved design (Taiwan) cutting wood to required shape and size with two operating keys as per direction of the Engineer-in-Charge. | Each | 96 | |||
| 93 | 35 | Providing and fixing with brass screws or specialty supplied screws hydraulic door closer Rayobi of approved design No.72, japan make, cutting wood etc., to required shape and size as per direction of engineer-in-charge. | Each | 98 | |||
| 94 | 36 | Providing and fixing fully glazed Champagne anodized aluminium Sliding windows as per British standard manufactured by Lucky, Prime, Chawla, Krudson and Pakistan Cables (fixing through their approved fabricators), Prime model box section 101mm x 30mm and 1.6mm thick including the cost of aluminium netting ,fittings, with all accessories cutting hole etc. and making good damages to walls etc. complete as required in any floor as per direction of engineer-in-charge, but excluding the cost of glass pans. | P.Sft | 1664 | |||
| 95 | 37 | Providing and fixing Tinted glass panes 5mm thick to M.S. Box pipe / Aluminium doors, windows and ventilators etc including the cost of labour but excluding the cost of M.S. square pipe beading, rubber packing and screw in any floor at any height. | P.Sft | 1664 | |||
| 96 | 38 | Providing and fixing MS Pipe size 3" dia, 16 Gauge using vertical supports for stair painted with two coats of red oxide paint including cutting to required section, welding etc cutting holes and making good damages to walls etc. complete as required. | P.Rft | 200 | |||
| 97 | 39 | Providing and fixing stair railing 3 feet height of M.S Square pipes 1-1/2" 1-1/2", 16 Gauge vertical on alternate step and M.S square pipe 3/4" x 3/4", 16 SWG 2 Nos, horizontal pipes and 2-1/2" x 2-1/2", 16 SWG, MS Suare pipe as top rail as per approved design including cutting, welding making holes fixing with sunk iron screws, painting two coats of red oxide paint etc. complete as required in any floor. | P.Rft | 200 | |||
| 98 | 40 | Providing and fixing kitchen cabinet wall mounted of 3/4" thick laminated board with best quality deodar wood frame and beading required section in approved patteren etc, fixed on wall eith rawal pugs, screws i/c cost of glue, nall, piano hinges, handles and painting or polishing etc as drawings complete all as respect. | |||||
| 99 | i | Wall mounted with 1/8" thick hard board backing. | P.Sft | 416 | |||
| 100 | ii | Floor mounted | P.Sft | 3080 | |||
| 101 | 41 | Providing and fixing approved chromium plated brass handles 5" (127 mm) size heavy type with necessary brass screws. | Each | 512 | |||
| 102 | 42 | Painting with (ICI) Dulux plastic emulsion paint VIP of approved shade two coats over and including the cost of one priming coat complete over plastered surface at any height in any floor . | 100 Sft | 82192 | |||
| 103 | 43 | Painting three coats with weather shield paint deluxe (ICI) make of approved shade on plaster surface (External) and including the cost of cleaning the surface, sand papering etc. complete at any height in any floor. | 100 Sft | 23904 | |||
| 104 | 44 | Painting iron work with synthetic enamel paint of approved make and shade two coats over and including the cost of one priming coat complete at any height in any floor. | 100 Sft | 5404 | |||
| 105 | 45 | Painting wood work with synthetic enamel paint of approved make and shade two coats over and including the cost of one priming coat complete at any height in any floor. | 100 Sft | 9728 | |||
| 106 | 46 | Providing and laying in floor C.C. 1:2:4: tuff paver 2-1/2" thick of approved design and colour pattren laid on sand cushion filling of joint with sand and warring etc. complete as per direction of Engineer Incharge. (the cost of sand cushion is included) | |||||
| 107 | i | b) Average Strength 5000 Psi | P.Sft | 31500 | |||
| 108 | 47 | Providing a two coats of bitumen emulsion at 10 Lbs. per % sft. (0.49 Kg/sm) on walls and floor in ground floor. | 100 Sft | 6902 | |||
| 109 | 48 | Providing and laying double layer of polythene sheet of 500 gauge (0.005 or 0.13 mm thick) under floors for water proofing laid as per specifications and instructions of the Engineer-in-Charge in ground floor. | 100 Sft | 6902 | |||
| 110 | 49 | Providing and Fixinf of Diamond Jumbolon insulation board 1-1/2" thick and polyphone sheet over diamond jumbolon insulation board for Roof Insulation as per direction of the Engineer Incharge in any floor in any height. | P.Sft | 6902 | |||
| 111 | 50 | Providing and laying 1st class burnt clay tiles of 9" X 4-1/2" X 1-1/2" size grouted with 1:3 cement mortar over 4" thick (avg) puddled earth compacted and smooth finished to slope mixed with bhoosa at the rate of one seer of bhoosa for one cft. of puddled earth in ground floor including flush pointing on tiles works with 1:3 cement mortar and curing complete. | 100 Sft | 6902 | |||
| 112 | 51 | Providing and fixing galvanized iron sheet of 22 gauge (1.15 mm thick) wall surface with sunken galvanized iron screws of required size as per direction of the Engineer-in-Charge. | P.Sft | 1120 | |||
| 113 | 52 | Providing and fixing 2" dia stainless steel pipe (18 guage) railing alongwith 4 Nos 3/4" dia parallel pipe having S/S pipe vertical post 2" dia at 3 ft C/C average spacing and 4" dia vertical post at start turning and end point i/c cost of labour, welding charges fitting & fixing in marble floor and wall etc complete as per direction of the Engineer incharge. | P.Rft | 920 | |||
| 114 | 53 | Providing and fixing windows roll up blinds sunscreen, darkout, or translucent fabric any colour / shade best quality (imported) with manual roll up arrangements complete in all respect with all other required accessories and hardware from the approved suppliers and manufactureres and hardware from the approved suppliers and manufacturers, as per direction of Engineer Incharge. | P.Sft | 1600 | |||
| 115 | 54 | Providing and laying 1:2:4 cement concrete Khurras 2" (51 mm) thick 2 ft. x 2 ft. (610 mm x 610 mm) size on roof including finishing with cement plaster 1:4, curing etc. complete. | Each | 20 | |||
| 116 | 55 | Providing and fixing 4" (100 mm) dia polyvinyl chloride rain water (PVC) down pipe with mild steel clamps, bolts and nuts fixed in cement concrete 1:2:4 etc. complete. | P.Rft | 280 | |||
| 117 | 56 | Providing and fixing 4" (100 mm) dia polyvinyl chloride (PVC) bend of any degree for rain water down pipe with clamps, bolts and nuts in cement concrete 1:2:4 etc. complete. | Each | 8 | |||
| 118 | Sub Head II - Water Supply & Sanitary Installations | ||||||
| 119 | 1 | Providing and fixing best quality squatting type white glazed earthenware W.C Pan, Pakistani (of not less than 18 Inches clear opening as measured between flushing rims) complete with and including the cost of best quality low level plastic flushing cistern of standard size with internal fittings complete, P.V.C. flushing pipe suitable for squatting type with extra bends and length with fittings, C.I. trap 4 inches (100mm) dia and making requisite number of holes in walls, plinth & floor for pipe connection and making good in cement concrete 1:2:4. | Each | 32 | |||
| 120 | 2 | Providing and fixing Pakistani make best available quality European style white glazed earthenware wash down W.C.Pan complete with and including the cost of a plastic seat (PVC cover and buffers 3 galns white glazed earthenware low level flushing cistern with siphon fittings, 1-1/2 inches (40mm) dia white porcelain enamelled flush bend, 3/4 inch (20mm) dia, G.I. warning pipe carried outside and bent vertically downwards and making requisite number of holes in walls, plinth and floor for pipe connections and making good in cement concrete 1:2:4. | Each | 32 | |||
| 121 | 3 | Providing and fixing 25 inches x 18 inches (635 mm x 457 mm) lavatory basin in white glazed earthenware (Pakistani) complete with and including the cost of brass oxidized bolts kit built into wall 1/2 inch (15 mm) dia. Chrome plated mixer 1-1/4" inches (32mm) rubber plug and chrome plated brass chain, 1-1/4 inches (32 mm) dia brass waste of approved pattern, 1-1/4 inches (32 mm) dia. Malleable iron or C.P. brass traps malleable iron or brass unions and making requisite number of holes in walls plinth and floor for pipe connections and making god in cement concrete 1:2:4. | Each | 64 | |||
| 122 | 4 | Providing manhole type 'A' size 2 feet x 1-1/2 feet or 610 mm x 457 mm( inside dimensions) x 2 feet (610 mm) deep as per approved design and specifications complete for 4 inches to 12 inches (100 mm to 305 mm) dia. Pipes upto 3 feet-11 inches (1.19 m) depth with 16 inches (406 mm dia.) (inside) cast iron cover and frame (weight = 1 Cwt. 1. Qtr.) (63.5 kg.) fixed in R.C.C.1:2:4 slab 4 inches (102 mm)( thick, burnt brick masonry walls 9 inches (229 mm) thick set in 1:4 cement mortar, 6 inches (150 mm) 1:3:6 C.C. in foundation, 1:2:4 C.C. in benching and 1/2 inch (13 mm) thick cement plaster in 1:3 C.M., to all inside walls surfaces channels and benching etc., and to top including making requisite number of main and branches channels but excluding the cost of excavation, back filling and disposal of excavated stuff, manhole cover and frame. | Each | 256 | |||
| 123 | 5 | Add for extra depth beyond 2 feet and up to 3 feet-11 inches for 'A' type manholes (for depth lesser than 2 feet or 610 mm deduct at the same rate). | P.Inch | 6144 | |||
| 124 | 6 | Providing manhole type 'B' size 3 feet x 2-1/2 feet or 914 mm x 762 mm (inside dimensions) x 4 feet (1219 mm deep as per approved design and specifications complete for 4 inches to 12 inches (100 mm to 305 mm) dia. Pipe 4 feet to 7 feet-5 inches (1.22 m to 2.26m) depth with 18 inches (457 mm) dia. (inside) cast iron cover and frame (weights 1 Cwt. 3 Qrs.) or 88.9 kg, fixed in R.C.C.1:2:4 slab 6 inches (152 mm) thick, 9 inches (229 mm) thick burnt brick masonry walls set in 1:4 C.M., 6 inches (152 mm) thick 1:3:6 C,C. in foundation, 1:2:4 C.C. in benching and 1/2 inch (13 mm) thick cement plaster in 1:3 C.M., to all inside wall surfaces, channels and benching etc. and to top including providing and fixing cast iron foot rest at every foot of depth and making requisite number of main and branch channels but excluding the cost of excavation, back filling, disposal of excavated stuff, manhole cover and frame. | Each | 128 | |||
| 125 | 7 | Add for extra depth beyond 4 feet and up to 7 feet-5 inches for 'B' type manholes (for depth lesser than 4 feet or 1219 mm deduct at the same rate). | P.Inch | 1536 | |||
| 126 | 8 | Making Connection with the existing manhole including the cost of cutting holes in walls, making them good in cement concrete 1:2:4 and making the required channel etc, complete. | Each | 20 | |||
| 127 | 9 | Providing and fixing un plasticized polyvinyl chloride pipe (U.P.V.C) "D" class and specials etc. including cutting and fitting complete with and including the cost of cutting trench upto 1-1/2 feet deep refilling, watering, ramming, and disposal of surplus earth within one chain and after cleaning the pipe and cartage within 10 miles (16.09 km.) (working pressure 12 kg/cm2) | |||||
| 128 | (i) Do Do. 4 inches (80 mm) dia pipe.. | P.Rft | 4000 | ||||
| 129 | (ii) Do Do. 3 inches (80 mm) dia pipe.. | P.Rft | 4000 | ||||
| 130 | (iii) Do Do. 2 inches (50 mm) dia pipe. | P.Rft | 2000 | ||||
| 131 | 10 | Excavation in all kinds of soil, murum, hard, average or soft including lift up to 5 feet (1.52 m) and lead up to one chain (30.48 m). | 100 Cft | 1000 | |||
| 132 | 11 | Providing and fixing un platisized polyvinyl chloride pipe (U.P.V.C) "D" class and specials etc. including cutting and fitting complete with and including the cost of cutting trench upto 1-1/2 feet deep refilling, watering, ramming, and disposal of surplus earth within one chain and after cleaning the pipe and cartage within 10 miles (16.09 km.) (working pressure 12 kg/cm2 ) 8 inches (200 mm) dia. | P.Rft | 1400 | |||
| 133 | 12 | Providing and Fixing PPRC pipe PN-20 with specials and clamps etc, including cutting and fitting complete with and including the cost of breaking through walls and roof making good etc, after cleaning the pipe and cartage within 10 miles. | |||||
| 134 | (i) Do. Do. 63mm dia pipe External Side | P.Rft | 1400 | ||||
| 135 | (ii) Do. Do. 50mm External Side | P.Rft | 1900 | ||||
| 136 | (iii) Do. Do. 40mm External Side | P.Rft | 1200 | ||||
| 137 | 13 | Providing and Fixing PPRC pipe PN-20 with specials and clamps etc, including cutting and fitting complete with and including the cost of breaking through walls and roof making good etc, after cleaning the pipe and cartage within 10 miles. | |||||
| 138 | (i) Do. Do. 32mm Internal Side | P.Rft | 3000 | ||||
| 139 | (ii) Do. Do. 25mm Internal Side | P.Rft | 3000 | ||||
| 140 | 14 | Providing and fixing standing wall shower of CP brass 3 knobs of approved quality mixer unit and moveable shower head complete. | Each | 64 | |||
| 141 | 15 | Providing and fixing bath room accessories of set of 6 pieces consist of one shelf, one towel rod with bracket, one towel ring, one soap dish, one tooth Brush holder with glass, one tissue paper holder one double hook etc complete of approved quality as per direction of Engineer in-charge. | Each | 64 | |||
| 142 | 16 | Providing and fixing approved quality stainless steel sink 60” x 20” Pak made (Atlas) complete with brass oxidized bolt kit/angle iron brackets built into walls ½” dia CP sink mixer 1-1/4” rubber plug and CP brass chain 1-1/4” CP brass waste 1-1/4” dia malleable iron or CP brass bottle trap with malleable iron or brass unions and making requisite number of holes in walls, plinth and floor for pipe connections and making good in cement concrete 1:2:4. | Each | 32 | |||
| 143 | 17 | P/F 3/4" thick granite(factory polished) of approved colour on vanity top i/c the cost of fixing in position with cement sand mortar 1:2, filling with jointing material of matching color, making holes for vanity basin, making round edging of exposed edges complete at any height in any floor as per directions of the Engineer in charge. (No deduction will be made for vanity holes) | P.Sft | 512 | |||
| 144 | 18 | Making connection with the existing GI pipe of size larger than 2 inches to 6 inches (50 mm to 150 mm) dia. including cutting the pipe and providing and fixing necessary fittings. | Each | 10 | |||
| 145 | 19 | Providing and fixing fully way gun metal valves with wheels threaded or flanged ends with rubber washers, (standard pattern).. | |||||
| 146 | (i) 3" dia | Each | 20 | ||||
| 147 | (ii) 2" dia. | Each | 30 | ||||
| 148 | (iii) 1" dia. | Each | 50 | ||||
| 149 | 20 | Providing and fixing best quality float valve complete as per direction of Engineer Incharge. | |||||
| 150 | (i) 2" dia. | Each | 4 | ||||
| 151 | (ii) 3" dia. | Each | 4 | ||||
| 152 | 21 | Providing and fixing 4" dia U.P.V.C floor trap of approved design i/c making requisite number of holes in walls, plinth and floor for pipe connection and making good in cement concrete 1:2:4. | Each | 96 | |||
| 153 | 22 | Providing and fixing 4" dia UPVC terminal guard of required dia etc complete and cartage within 10 miles. | Each | 64 | |||
| 154 | 23 | Providing and fixing u.P.V.C Y-Tee of required degree etc. complete. 4"x4"x4" | Each | 200 | |||
| 155 | 24 | Providing and fixing 4" dia U.P.V.C plain bend of required degree etc. complete. | Each | 240 | |||
| 156 | 25 | Providing and fixing chromium plated Muslim bib-cock with Muslim Shower of approved quality. | Each | 64 | |||
| 157 | 26 | Providing and fixing 1/2 inches dia (15mm) CP bib Cock | Each | 64 | |||
| 158 | 27 | Providing and fixing 1/2" Single dia bib cock / stop cock (Master / Sonex make) with approved knob etc. complete. | Each | 64 | |||
| 159 | 28 | P/F mirror 6mm thick (imported) fixed with silicon paste / C.P clips etc. complete as per direction of Engineer-in-Charge. | P.Sft | 64 | |||
| 160 | 29 | Providing and fixing floor waste 6"x6" (Stainless Steel) Jali etc complete. | Each | 232 | |||
| 161 | 30 | Providing and fixing 1/2 inches dia (15mm) CP stop cock / Tee Stop cock. | Each | 400 | |||
| 162 | 31 | Providing and fixing CP Mixer 1/2 inches (15mm) (Faisal/Master or equivelent) lever type pakistani complete in all respect. | Each | 64 | |||
| 163 | Sub Head III - E & M Works | ||||||
| 164 | 1 | Wiring for light, fan or call bell point with 1.5 mm² single core, PVC insulated wire copper conductor wire in 20 mm (3/4")dia uPVC conduit recessed in the wall or column, roof etc. including 1mm² single core PVC insulated wire as ECC as required. | Per Point | 1364 | |||
| 165 | 2 | Wiring for two way light point with 1.5 mm2 single core, PVC insulated wire copper conductor wire in 20 mm (3/4")dia uPVC conduit recessed in the wall or column, roof etc. including Immz single core PVC insulated wire as ECC as required. | Per Point | 16 | |||
| 166 | 3 | Extension/Additional wiring for light, fan or call bell point controlled with same switch with 1.5mm² PVC insulated wire in 20 mm (3/4")dia PVC conduit recessed in the wall or column, including1mm² PVC insulated wire as ECC as required. | Per Point | 1012 | |||
| 167 | 4 | Wiring for submain with 2 x 2.5 mm², PVC insulated wire 300/500 volts grade, single core, stranded coppe conductor wire in 20 mm (3/4'') dia PVC conduit recessed in the wall, column and roof etc including 1.5 mm² insulated wire sinfle core as ECC as required. | Per RM | 11260 | |||
| 168 | 5 | Wiring for submain with 2 x 4 mm², PVC insulated wire 300/500 volts grade, single core, stranded coppe conductor wire in 20 mm (3/4'') dia PVC conduit recessed in the wall, column and roof etc including 1.5 mm² insulated wire sinfle core as ECC as required. | Per RM | 3660 | |||
| 169 | 6 | Wiring for sub-main with 2 x 6 mm², PVC insulated wire 300/500 volts grade, single core, stranded copper conductor wire in 25 mm (1")dia uPVC conduit recessed in the wall, column and roof etc including 2.5 mm² Pvc insulated wire single core wire as ECC as required. | Per RM | 1408 | |||
| 170 | 7 | Wiring for sub-main with 2 x 10 mm², PVC insulated wire 300/500 volts grade, single core, stranded copper conductor wire in 25 mm (1")dia uPVC conduit recessed in the wall, column and roof etc including 2.5 mm² Pvc insulated wire single core wire as ECC as required. | Per RM | 704 | |||
| 171 | 8 | Providing & laying 4 core, 16 mm2 PVC insulated & PVC sheathed, 600/1000 volts grade with stranded copper conductor , un armoured, L.T cable in existing all kind of conduit or cable duct as per Pak. P.W.D specification as required. | Per RM | 418 | |||
| 172 | 9 | Providing & laying 4 core, 95 mm2 PVC insulated & PVC sheathed, 600/1000 volts grade with stranded copper conductor , armoured underground, L.T cable buried in the ground dully covered with sand and warning cable tiles as per Pak. P.W.D specification as required. | Per RM | 660 | |||
| 173 | 10 | Supply & drawing of 10 mm2, single core, PVC insulated wire in all kinds of existing or given conduit/cable duct as required. ( | Per RM | 418 | |||
| 174 | 11 | Supply & drawing of 16 mm2, single core, PVC insulated wire in all kinds of existing or given conduit/cable duct as required. | Per RM | 660 | |||
| 175 | 12 | Providing & fixing pilot lamp set fitted on existing board I/c connection as required. | P.Set | 70 | |||
| 176 | 13 | Supply & fixing 30 mm dia uPVC conduit with all especial such as bends, sockets, Junction etc fItted on surface as required. | Per RM | 2068 | |||
| 177 | 14 | Making Termination of 3 or 4 core, 16 mm2 to 25 mm2 armoured / un-armoured copper conductor, PVC x PVC L.T Cable including providing & fixing proper lugs, etc complete in all respect as required. | Per Job | 36 | |||
| 178 | 15 | Making Termination of 3 or 4 core, 70 mm2 to 95 mm2 armoured / un-armoured copper conductor, PVC x PVC L.T Cable including providing & fixing proper lugs, etc complete in all respect as required. | Per Job | 10 | |||
| 179 | 16 | Providing & fixing 6 to 32 Amps, S.P MCCB fixed on existing board, i/c inter-connection as required. | Each | 704 | |||
| 180 | 17 | Providing & fixing 6 to 32 Amps, DP MCCB fixed on metal board recessed in the wall duly covered with fiber sheet, 1/c inter-connection as required. | Each | 352 | |||
| 181 | 18 | Providing & fixing 20 to 100 Amps, (Adjustable - High Breaking Capacity) 4 Pole circuit breaker fixed on existing board, i/c inter-connection as required. | Each | 36 | |||
| 182 | 19 | Providing & fixing 160 to 250 Amps, (Adjustable - High Breaking Capacity) 4 Pole circuit breaker fixed on existing board, i/c inter-connection as required. | Each | 10 | |||
| 183 | 20 | Providing & fixing cubical type metal sheet vermin protected Distribution board as per drawing with locking arrangement duly powder coated i/c all fastening devices and electrical wire /leads for internal conection complete as required. (Different sizes, outdoor type) | Per Sft | 142 | |||
| 184 | 21 | Providing & fixing cubical type metal sheet vermin protected LT panel board as per drawing with locking arrangement duly powder coated i/c all fastening devices and electrical wire/ leads for internal connection complete as required. | Per Sft | 8 | |||
| 185 | 22 | Providing & fixing 10 to 60 Amps, 4 pole, three phase bus bar strip fitted in given Distribution board complete with bus bar insulator, screws, bolts etc as required. | Each | 32 | |||
| 186 | 23 | Providing & fixing 160 to 200 Amps, 4 pole, three phase bus bar strip fitted in given Distribution board complete with bus bar insulator, screws, bolts etc as required. | Each | 8 | |||
| 187 | 24 | Providing & fixing 10 Amps Polycarbonate flame retardant S.P switch with fancy required gang plate fixed on die fabricated, powder coated metal board recessed in wall or column including connection as required. | Each | 1550 | |||
| 188 | 25 | Providing & fixing 10 Amps Polycarbonate flame retardant Two way switch with fancy gang plate fixed on die fabricated, powder coated, metal board recessed in wall or column including connection as required. | Each | 36 | |||
| 189 | 26 | Providing & fixing 10 Amps Polycarbonate flame retardant 2-Pin switch socket unit (Universal) with fancy gang plate fixed on die fabricated, powder coated metal board recessed in wall or column including connection as required. | Each | 422 | |||
| 190 | 27 | Providing & fixing 13 Amps Polycarbonate flame retardant 3-Pin switch socket unit with fancy gang plate fixed on die fabricated, powder coated metal board recessed in wall or column including connection as required. | Each | 1056 | |||
| 191 | 28 | Providing & fixing 15 Amps Polycarbonate flame retardant 3-Pin switch socket unit with fancy gang plate fixed on die fabricated, powder coated metal board recessed in wall or column including connection as required. | Each | 422 | |||
| 192 | 29 | Providing & fixing 10 Amps Polycarbonate flame retardant Bell Push with fancy gang plate fixed on die fabricated, powder coated, metal board recessed in wall or column including connection as required. | Each | 64 | |||
| 193 | 30 | Providing & installing 140 Cm (56") sweep inverter ceiling fan with blades, canopy, strandard length of down rod including connection and all required accessories with 14.0076" flexible wire complete as required. Millat/Pak/GFC/ Younas/Royal. | Each | 212 | |||
| 194 | 31 | Providing & installing 30 Cm (12") sweep, metallic body Exhaust fan complete with blades. motor, etc fitted in existing hole including connection with 14/.0076" flexible wire complete as required | Each | 70 | |||
| 195 | 32 | Providing & installing 25 Cm ( 10") sweep, Plastic body Exhaust fan complete with blades, motor, etc fixed in existing hole including connection with 14/.0076" flexible wire complete as required. | Each | 140 | |||
| 196 | 33 | Providing & fixing 6 Amps plastic ceiling rose on PVC Round block/Round Cover fitted on surface including connection as required | Each | 100 | |||
| 197 | 34 | Providing & fixing 4" X 4" size MS die casted, Powder coated recessed type fan clamp box with 1/2" dia MS bar fan clamp fixed in roof at casting time as required. | Each | 212 | |||
| 198 | 35 | Providing, installation, testing & commissioning of recessed / surface mounted LED 7-10 Watt ceiling light/downlight including driver having warm/natural white /cool white colour, 80-90 Im/watts efficiency 0.9 or above power factor, 20000-25000 hours life cycle, including connections complete in all respect as approved by the Engineer Incharge. a) | Each | 1268 | |||
| 199 | 36 | Providing, installation, testing & commissioning of recessed / surface mounted LED 12 Watt ceiling light/downlight including driver having warm/natural white /cool white colour, 80-90 Im/watts efficiency 0.9 or above power factor, 20000-25000 hours life cycle, including connections complete in all respect as approved by the Engineer Incharge. | Each | 422 | |||
| 200 | 37 | Providing, installation, testing & commissioning of recessed / surface mounted LED 18-20 Watt ceiling light/downlight including driver having warm/natural white /cool white colour, 80-90 Im/watts efficiency 0.9 or above power factor, 20000-25000 hours life cycle, including connections complete in all respect as approved by the Engineer Incharge. | Each | 124 | |||
| 201 | 38 | Providing, Inr Commissioning of 04 feet, 36 watt LED Tube / Batten Lights including driver haqng warm / Neutral White / cool white colour.80-90 Im/watts efficiency, 0.9 or above power factor, 10000-15000 hours life cycle, including connection, complete in all respect as approved by the Engineer Incharge. | Each | 212 | |||
| 202 | 39 | Providing, Inr Commissioning of 02 feet, 18-20 watt LED Tube / Batten Lights including driver haqng warm / Neutral White / cool white colour.80-90 Im/watts efficiency, 0.9 or above power factor, 10000-15000 hours life cycle, including connection, complete in all respect as approved by the Engineer Incharge. | Each | 140 | |||
| 203 | 40 | Providing, Installation, Testing & Commissioning of 5-7 watt Emergency Light (surface/recessed), including connection, complete in all respect as approved by the Engineer Incharge. | Each | 22 | |||
| 204 | 41 | Providing, Installation, Testing & Commissioning of 2 watt Emergency Exit Light , including connection, complete in all respect as approved by the Engineer Incharge. | Each | 36 | |||
| 205 | 42 | Providing and fixing standard ceiling suspended pendant light fitting, supporting 01 No. built in led source or led lamp, including hanging cord complete in all respect, of design/make/shape/finish as approved by the Engineer Incharge. | Each | 64 | |||
| 206 | 43 | Providing and fixing outdoor wall mounted water proof led light fitting with rust proof and anticorrosion metal body, complete in all respect, of approved design/make/shape, as approved by the Engineer Incharge. | Each | 32 | |||
| 207 | 44 | Proving and fixing 6"x4" MS perforated cable tray, 16 SWG complete with cover of 18 SWG including painting and support system. | Per RM | 200 | |||
| 208 | 45 | Providing, Installation. Testing & Commissioning of Flood Lights, 180-201 watts, (IP66) including driver, having neutral white / cool white colour,110 -120 Im/watts efficiency; 0.9 or above power factor. 20000-25000 hours life cycle, including connection, complete in all respect as approved by the Engineer Incharge. ) | Each | 32 | |||
| 209 | 46 | Supply & fixing 20 mm ( 3/4") dia uPVC conduit with all especial such as bends, sockets, Junction etc fitted on surface as required. | Per RM | 220 | |||
| 210 | 47 | Supply & fixing 25mm ( 1") dia uPVC conduit with all especial such as bends, sockets, Junction etc fitted on surface as required. | Per RM | 220 | |||
| 211 | 48 | Providing & fixing of 16x60 mm uPVC duct fitted on surface as required | Per RM | 220 | |||
| 212 | 49 | Providing & fixing of 25x60 mm uPVC duct fitted on surface as required. | Per RM | 220 | |||
| 213 | 50 | Providing & fixing Three phase 15 to 90 Amps, 400/440 volts energy meter fitted on existing board I/c connection as required. | Each | 4 | |||
| 214 | 51 | Providing and fixing Earthing set with 2'x2'x1/4" copper plate buried in the ground at a depth of 12 feet or less if water comes out from the ground level (withsalt and charcoal.or Earthing chemical Powder) etc making the pit 12 feet deep by excavation of all type of soil (except soft or hard rock) i/c fixing of 8 SWG copper wire in 1/2 " G.I conduit completein all respect as required. | Per Job | 14 | |||
| 215 | 52 | Providing and fixing 1" diameter 3ft long lighting-copper rod with five spikes and balls on its head as required. | Per Job | 18 | |||
| 216 | 53 | Providing and fixing 1-1/2" x 1/3" thick copper strip with suitable saddle at 12" intervals completeas required. | Per RM | 440 | |||
| 217 | 54 | Providing, fixing and commissioning Pad mounted, step down 11000/ 400 volts, 200 KVA three phase, 50Hz, Transformer as per electricity code complete in all respect as reqd. | Each | 2 | |||
| 218 | 55 | Providing and laying HT 11 KV, 3 core, 35 mm2 stranded copper conductor, XLPE insulated. cu tape screened PVC bedded and PVC sheathed armoured cable, laid in existing all kind of pipes, cable duct, channels etc as per Pak.P.W.D specification as required. (without Termination) | Per RM | 30 | |||
| 219 | 56 | Providing and fixing indoor/outdoor, 3 core, 16 mm2 to 35 mm2, 11KV, XLPE. heat shrink termination ends Kit complete in all respect as required. | Per Job | 4 | |||
| 220 | 57 | Providing and fixing HT,11 KV indoor/outdoor type fuse D link /cut off fuse assembly set of three pieces complete with fuse fitted on angle iron base frame as required.(with out termination) | Each | 6 | |||
| 221 | 58 | Providing & fixing 400 to 630 Amps,(Adjustable - High Breaking Capacity) 4 Pole circuit breaker fixed on existing board , i/c inter-connection as required. | Each | 2 | |||
| 222 | 59 | Providing & fixing LT Service Box, as per Wapda specifications complete in all respect as approved by the engineer Incharqe. | Each | 2 | |||
| 223 | 60 | Providing & fixing mono block pumping set complete with 2 HP pump 2850/2900 RPM complete with AC 220V single phase motor on a common base plate having suction & discharge 1-1/2” x 1-1/2” as approved. | Each | 4 | |||
| 224 | 61 | Providing & fixing mono block pumping set complete with 3 HP pump 2850/2900 RPM complete with AC 220V single phase motor on a common base plate having suction & discharge 2” x 1-1/2” as approved. | Each | 4 | |||
| 225 | 62 | Providing, Installing, Testing & Commissioning of Dual Supply (Gas & Electric) Geysers, 35 Gallons capacity, with fully automatic thermostat, complete in all respect, as approved by the Engineer Incharge | Per Job | 64 | |||
| 226 | 63 | Providing and fixing Kitchen Hob, 3 burner 30 inch size auto ignition glass top superior quality complete in all respect i/c making necessary connection with gas line complete in all respect as approved by the Engineer Incharge | Per Job | 64 | |||
| 227 | 64 | Providing and fixing Kitchen Hood superior quality with SS canopy filter front and back made up of tempered glass, powerful blower motor, LED light and touch control as approved etc complete in all respect i/c electrical connection as required. | Per Job | 64 | |||
| 228 | Total (S.H-I + S.H-II + S.H-III) | 383310636 | |||||
| GRAND TOTAL: | Rs 383,310,636.00 |
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
The Supplier is:
The title of the subject procurement is: CONSTRUCTION OF 32 NO. JS APARTMENTS (02 BED) FOR ASF AT IIAP ISLAMABAD.
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director
Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
+92-315-983-2148
muhammadsuleman@paa.gov.pk
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director
Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
+92-315-983-2148
muhammadsuleman@paa.gov.pk
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.05% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 5.00% of the contract price in acceptable form of Bank Guarantee
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P71351
To: Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., CONSTRUCTION OF 32 NO. JS APARTMENTS (02 BED) FOR ASF AT IIAP ISLAMABAD. (P71351) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: Islamabad International Airport (Pakistan Airports Authority) (Pakistan Airports Authority (PAA)), Deputy Director Landside Division, Islamabad International Airport, Islamabad, Islamabad Capital Territory
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}