In terms of Rules 48 of Public Procurement Rules, 2004 Grievance Redressal Committee (GRC) is notified for the subject procurement and notification copy is available on the procuring agency’s website and on Authority’s website at (www.ppra.org.pk).
SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer
SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
+92-315-720-2000
akhtar.munir@sbp.org.pk
The following specific data for the procurement of Goods to be procured shall complement, supplement, or amend the provisions in the Instructions to Bidders (ITB). Whenever there is a conflict, the provisions herein shall prevail over those in ITB.
|
BDS Clause Number |
ITB Number |
Amendments of, and Supplements to, Clauses in the Instruction to Bidders |
A. Introduction |
||
|
1 |
1.1 |
Name of Procuring Agency: SBP-BSC North (SBP Banking Services Corporation (BSC)) The subject of procurement is: UPGRADATION AND IMPROVEMENT OF ELECTRICAL SYSTEM AT SBP BSC (BANK) NORTH NAZIMABAD Expected commencement date: Wednesday, March 31, 2027 |
|
2. |
2.1 |
Financial year for the operations of the Procuring Agency: 2026-27 Name and identification number of the Contract: P103714 |
| 3. | 3.1 | JV/Consortium or Association Allowed: No Number of JV/Consortium Members: Nil |
B. Bidding Documents |
||
|
4. |
6.2 & 6.4 |
The Bidders may seek clarifications through EPADS v2.0: Clarification Date: Sunday, November 1, 2026 |
| 5. | 7.2 |
Any addendum, in case issued, shall be published on SBP-BSC North (SBP Banking Services Corporation (BSC)) website and on EPADS v2.0. |
C. Preparation of Bids |
||
| 6. |
8.1 |
List of documents required along with the bid: No |
| 7. | 9.1 |
The qualification criteria to establish the supply / production capability of the bidder. see Eligibility Criteria |
| 8. | 11.2 |
|
| 9. | 11.1 | Price schedule will be provided according to the format defined and acquired. see section price schedule. |
| 10. | 11.4 |
Specifications: see section of specifications. |
|
11. |
11.5 & 13.5 |
The price shall be Fixed. |
| 12. |
14.1 |
Currency of the Bids shall be : PKR |
| 13. |
16.1 |
The Bids/Bid Validity period shall be: 180 Days |
| 14. |
17.1 |
The amount of Bid Security shall be as defined in Bid Security Section for items and lots given in BDS 6 |
| 15. | 17.2 |
The Bid Security shall be in the form of: Pay Order, Banker's Cheque, Call at Deposit, Demand Draft |
| 16. | 15.1 |
Alternative Bids to the requirements of the bidding documents will not be permitted. |
D. Submission of Bids |
||
|
17. |
18.1 & 21.1 |
Bid shall be submitted online on EPADS v2.0 whereas hard copy of the bid security should be submitted to the following; SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province). Bids that are not submitted on EPADS v2.0 shall be disqualified. The deadline for Bids submission is: Wednesday, November 4, 2026 03:00 PM |
E. Opening and Evaluation of Bids |
||
|
18. |
24.1 |
The Bids opening shall take place on EPADS v2.0. Day : Wednesday Date: November 04, 2026 Time : 03:30 PM |
|
19. |
30.2 |
Selection technique adopted will be: Least Cost Based Selection (LCBS) |
F. Award of Contract |
||
|
20. |
41.1 & 41.2 |
The Performance guarantee shall: 10.00%. The Performance Guarantee shall be acceptable in the form of: Pay Order, Banker's Cheque, Call at Deposit, Bank Guarantee, Demand Draft |
| 21. | 45.1 |
Arbitrator shall be appointed by mutual consent of the both parties. |
G. Review of Procurement Decisions |
||
|
22. |
37 |
Grievance against this procurement shall be submitted online on EPADS v2.0. |
| Bidder's Type | Required Registration |
|---|---|
| Individual / Individual Consultant Sole Proprietorship Partnership Firm Company (Private Limited) Company (Public Limited) Company (Holding Company) Company (Limited by Guarantee) State Owned Enterprise (Private Limited) State Owned Enterprise (Public Limited) | FBR (NTN) PEC |
| Eligibility Criteria | Document |
|---|---|
| Revenue Authority Registration: The Bidder should be registered with relevant / concerned Provincial Revenue Authority. If not registered, the 100% tax shall be deducted at source as per applicable law and credited to relevant account. | No |
| Valid registration with Pakistan Engineering Council at least in Category C-03, or above with specialized category EE-04 and EE-05. | Yes |
| Undertaking/Letter of Bid (As per Format attached): The bidder is required to submit an undertaking/letter of bid as per format attached. | Yes |
Least Cost Based Selection (LCBS)
Weightage
| Technical Evaluation % |
|---|
| 100 |
| Technical Marks | 100 | |
|---|---|---|
| Passing Marks | 100 | |
| Technical Evaluation Criteria | ||
| Minimum experience of the company/ firm should not less than five (05) Years for performing works related to Electrical system (The bidder shall provide documentary evidence such as work order / acceptance letter / completion certificate / Contract documents or any other tractable evidence) (Quantitative)(Doc Required) | 20 | |
| The bidder should have executed minimum One (01) project of supply & installation of 1000KVA transformer or above, HT/LT Panels of cost Rs. 120 Million during last five (05) year. OR The bidder should have executed minimum Two (02) projects of electrical supply and installation works including 1000KVA transformer or above and MV/LV panels of cost 80.0M executed during last five (05) years (The bidder shall provide documentary evidence such as work order/ completion certificate / Contract documents showing scope of works) (Quantitative)(Doc Required) | 20 | |
| Available Financial Capability/Liquid Assets of Rs. 80M or above. (Bank statement be submitted as evidence showing required balance at any one instant in the statement of last three months before date of publication of tender notice or available Bank Credit Line facility during same period or Liquid Assets). OR Annual Sales volume/Gross Turnover of at least Rs. 150M in any of the last 03 (three) years Attach Copy(s) of Audited Financial Statements / Sales Tax/ Income Tax return filed in FBR/ purchase orders or work orders (Quantitative)(Doc Required) | 30 | |
| The bidder/contractor shall provide technical brochures of quoted equipment complying with specification mentioned in Bill of Quantities (BOQ) and Schedule of Specifications Appendix A to Bid (Quantitative)(Doc Required) | 10 | |
| The Bidder shall submit a valid support/authorization letter from the OEM of the proposed Synchronization Controller(s) or its Authorized Distributor, authorizing the Bidder for supply, installation, commissioning, and after-sales support. The OEM or Authorized Distributor shall: Hold valid OEM authorization/dealership credentials for the quoted controller brand for the last three (03) consecutive years, including the current year. Have a minimum of ten (10) years' experience in synchronization controllers, power management, generator synchronization, or related automation and control systems. Maintain a technical support office in Karachi, Pakistan. Provide technical support, warranty services, and spare parts for the proposed equipment. (Quantitative)(Doc Required) | 20 | |
Jobs Without Lots :
| Job | Delivery Schedule | Quantity | Bid Security |
|---|---|---|---|
| UPGRADATION AND IMPROVEMENT OF ELECTRICAL SYSTEM AT SBP BSC (BANK) NORTH NAZIMABAD | Address: SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province). Schedule: 540 Days Quantity: 1/job |
1/job | 4000000 PKR |
No
Jobs Without Lots :
Job: UPGRADATION AND IMPROVEMENT OF ELECTRICAL SYSTEM AT SBP BSC (BANK) NORTH NAZIMABAD
Specifications / Requirements:
| Sr. No | S.# | DESCRIPTION | UNIT | QTY | RATE | AMOUNT IN WORDS | AMOUNT |
|---|---|---|---|---|---|---|---|
| 1 | SECTION - A MEDIUM VOLTAGE SWITCHGEAR | ||||||
| 2 | Minimum Two Year Warranty required, warranty period will start from the date of successful Testing & Commissioning. NOTE: - Shop drawings with complete technical details shall be submitted for approval before manufacturing. - The Contractor shall facilitate a comprehensive Factory Acceptance Test (FAT) at the manufacturer's facility for all LV/MV panels prior to dispatch. The testing shall be witnessed by the Client/Consultant. | ||||||
| 3 | A-1/1 | Supply of following 11KV Incoming MV Type Tested Switchgear (Cassette Type) comprising with motor mechanism, metering and all protection devices CTs, PTs, Over current Protection, IBMS Complied along with Energy Analyzer, earth Fault Relay including complete interlocking facility by adding blocking coils, UVT, coils etc. Panel shall have provision for Cable Entry/Exit from TOP along with cable chamber box termination of minimum 450mm x 1200mm including seperate trolly for VCB drawout, Complete with all respects having following specifications: The (80x10mm) Cu Bus Bars shall be Tin Plated using Electroplating Method and covered with Heat Shrink Color Coded Sleeves. Complete in all respect. Breaker type: VCB Rate Voltage: 12kV Rated Current : 630A TP Busbar: Pure Copper Tinned With Sleeves BIL: 75kV Supply Frequency: 50 Hz Rated Power Frequency Withstand Voltage: 28 kV Rated Short Circuit Breaking Current Rating : 20KA for 3 sec. MV Panel must be Type Tested with operator safety IAC qualification FLR All Controls of VCB shall be 220V AC AC supply should be provided by client DC power supply should be supplied by supplier if required Each Panel Shall have Sensor for humidity & temparature with de-humidifirer. Note: -All protection relays must be self-powered -To be Coupled with the below mentioned 2 No. Outgoing Switchgears Minimum Two Year Warranty required, warranty period will start from the date of successful Testing & Commissioning. - Shop drawings with complete technical details shall be submitted for approval before manufacturing. - The Contractor shall facilitate a comprehensive Factory Acceptance Test (FAT) at the manufacturer's facility for all LV/MV panels prior to dispatch. The testing shall be witnessed by the Client/Consultant. | No. | 1 | 6989346 | Rupees Six Million Nine Hundred Eighty Nine Thousand Three Hundred Forty Six Only | 6989346 |
| 4 | A-1/2 | Placement, Transportation, Loading/Unloading, Installation, Testing & Commissioning of above item at S.# A-1/1 | No. | 1 | 123714 | Rupees One Hundred Twenty Three Thousand Seven Hundred Fourteen Only | 123714 |
| 5 | A-2/1 | Supply of 11KV Phase Reversal Correction Panel (Cassette Type) comprising with motor mechanism, metering and all protection devices CTs, PTs, Over current Protection, IBMS Complied along with Energy Analyzer, earth Fault Relay including complete interlocking facility by adding blocking coils, UVT, coils etc. Panel shall have provision for Cable Entry/Exit from TOP along with cable chamber box termination of minimum 450mm x 1200mm, Complete with all respects having following specifications: The (80x10mm) Cu Bus Bars shall be Tin Plated using Electroplating Method and covered with Heat Shrink Color Coded Sleeves. Complete in all respect. Breaker type: VCB Rate Voltage: 12kV Rated Current : 630A TP Busbar: Pure Copper Tinned With Sleeves BIL: 75kV Supply Frequency: 50 Hz Rated Power Frequency Withstand Voltage: 28 kV Rated Short Circuit Breaking Current Rating : 20KA for 3 sec. MV Panel must be Type Tested with operator safety IAC qualification AFLR All Controls of VCB shall be 220V AC AC supply should be provided by client DC power supply should be supplied by supplier if required Each Panel Shall have Sensor for humidity & temparature with de-humidifier. Note: -All protection relays must be self-powered -To be Coupled with the below mentioned 2 No. Outgoing Switchgears | No. | 1 | 6989346 | Rupees Six Million Nine Hundred Eighty Nine Thousand Three Hundred Forty Six Only | 6989346 |
| 6 | A-2/2 | Placement, Transportation, Loading/Unloading, Installation, Testing & Commissioning of above item at S.# A-2/1 | No. | 1 | 123714 | Rupees One Hundred Twenty Three Thousand Seven Hundred Fourteen Only | 123714 |
| 7 | A-3/1 | Supply of 11KV Outgoing MV Switchgear (Cassette Type) comprising with motor mechanism and all protection devices CTs, PTs, Over current Protection, IBMS Complied along with Energy Analyzer, earth Fault Relay, earthing switch, including complete interlocking facility by adding blocking coils, UVT, coils etc. Panel shall have provision for Cable Entry/Exit from TOP along with cable chamber box termination of minimum 450mm x 1200mm, Complete with all respects having following specifications: The (80x10mm) Cu Bus Bars shall be Tin Plated using Electroplating Method and covered with Heat Shrink Color Coded Sleeves. Complete in all respect. Breaker type: VCB Rate Voltage: 12kV Rated Current : 630A TP Busbar: Pure Copper Tinned With Sleeves BIL: 75kV Supply Frequency: 50 Hz Rated Power Frequency Withstand Voltage: 28 kV Rated Short Circuit Breaking Current Rating : 20KA for 3 sec. MV Panel must be Type Tested with operator safety IAC qualification FLR All Controls of VCB shall be 220V AC AC supply should be provided by client DC power supply should be supplied by supplier if required Each Panel Shall have Sensor for humidity & temparature with de-humidifier. (To Be Coupled with the above mentioned Incoming / Phase Reversal Switchgear) | No. | 2 | 6825751 | Rupees Thirteen Million Six Hundred Fifty One Thousand Five Hundred Two Only | 13651502 |
| 8 | A-3/2 | Placement, Transportation, Loading/Unloading, Installation, Testing & Commissioning of above item at S.# A-3/1 | No. | 2 | 123714 | Rupees Two Hundred Forty Seven Thousand Four Hundred Twenty Eight Only | 247428 |
| 9 | A-4/1 | Supply of 600mm wide, 6 mm thick Rubber mat piece to be installed all along Switchgear in substation rooms as per requirements and specifications, complete in all respect. | Rm. | 15 | 6786 | Rupees One Hundred One Thousand Seven Hundred Ninety Only | 101790 |
| 10 | A-4/2 | Laying of above item at S.# A-4/1 | Rm. | 15 | 124 | Rupees One Thousand Eight Hundred Sixty Only | 1860 |
| 11 | A-5/1 | Supply of Danger Boards, Emergency Signs etc. including all mounting accessories, complete in all respects. | Job | 1 | 26100 | Rupees Twenty Six Thousand One Hundred Only | 26100 |
| 12 | A-5/2 | Installation, Testing & Commissioning of above item at S.# A-5/1 | Job | 1 | 6186 | Rupees Six Thousand One Hundred Eighty Six Only | 6186 |
| 13 | A-6/1 | Supply and delivery of a loose, fully operational, truck-mounted Vacuum Circuit Breaker (VCB) trolley, completely compatible and interchangeable with the 11kV IAC AFLR switchgear panels specified above. | No. | 1 | 55098 | Rupees Fifty Five Thousand Ninety Eight Only | 55098 |
| 14 | A-7 | Physical Factory Acceptance Test at the manufacturer's premises for 2 Persons (1 No. Client's Representative & 1 No. Consultant's Representative with supplier) | Job | 1 | 61857 | Rupees Sixty One Thousand Eight Hundred Fifty Seven Only | 61857 |
| 15 | Note: ● Vendor is advised to inform missing items (if any) in BOQ at time of submitting this tender. No escalation will be considered at time of execution of work. ● Vendor to check placement of MV switch gear on substation room and make necessary arrangement for it accordingly as per site condition. | ||||||
| 16 | SECTION - B OIL FILLED TRANSFORMER | ||||||
| 17 | B-1/1 | Supply of Oil Filled Step Down Distribution Transformers including all protection devices CTs, PTs, PRD relay etc. Complete in all respects and having following specifications: Rated power: 1000kVA Phase: 3 Phase Rated frequency: 50 Hz Rated primary voltage: 11 kV Secondary voltage ( at no-load): 415 V Vector group: Dyn11 Basic Insulation Level: 95kV Dielectric liquid: Mineral oil Cooling mode: ONAN (oil natural air natural) Type of installation: Indoor Mounting mode: Ground / Pad Mounted Degree of protection: IP00 no enclosure IEC | No. | 2 | 9487089 | Rupees Eighteen Million Nine Hundred Seventy Four Thousand One Hundred Seventy Eight Only | 18974178 |
| 18 | B-1/2 | Placement, Transportation, Loading/Unloading, Installation, Testing & Commissioning of above item at S.# B-1/1 | No. | 2 | 309285 | Rupees Six Hundred Eighteen Thousand Five Hundred Seventy Only | 618570 |
| 19 | B-2/1 | Supply of wiring for bucholz relay, alarm control etc. for above Transformers from transformers to MV Panels with 3x1C-2.5 Sqmm Cu/PVC cables in 25mm dia G.I conduit with all accessories, complete as per drawing and specification. | Rm. | 50 | 1044 | Rupees Fifty Two Thousand Two Hundred Only | 52200 |
| 20 | B-2/2 | Installation, laying, tagging, termination, testing and commissioning of above item at S.# B-2/1 | Rm. | 50 | 118 | Rupees Five Thousand Nine Hundred Only | 5900 |
| 21 | B-3 | Physical Factory Acceptance Test at the manufacturer's premises for 2 Persons (1 No. Client's Representative & 1 No. Consultant's Representative with supplier) | Job | 1 | 309285 | Rupees Three Hundred Nine Thousand Two Hundred Eighty Five Only | 309285 |
| 22 | SECTION - C LV PANELS & DISTRIBUTION BOARDS | ||||||
| 23 | Supply, Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of the following LV Panels/Distribution boards made with 14 SWG Sheet Steel Enclosure including all installation accessories such as Rawal bolt etc. Complete in all respects. Note: - Imported Bi-Mettalic Lugs and Connectors shall be used in existing LV Cables. - Manual crimping of lugs is not allowed. Proper hydraulic lug presser should be used. - All the DBs should be front accessible and maintainable. - The transportation & unloading of Panels is to be done by Panel Supplier. - Laser engraved tags required as mention in SLDs - Space for circuit tagging required with permanent installation on protective sheet via rivets - 20% space required in DB for future provision - Tin platted Imported Cu bus bar with heat shrink color coded sleeves to be used. - Hindged protective metallic door is required with knob/handle. - Braided Door earth required. - Lockable handle required for main door. - As-built drawing pocket. - Cable hanging arrangement. - Shop drawings with complete technical details shall be submitted for approval before manufacturing. - The Contractor shall facilitate a comprehensive Factory Acceptance Test (FAT) at the manufacturer's facility for all LV/MV panels prior to dispatch. The testing shall be witnessed by the Client/Consultant. Minimum Two Year Warranty Required from date of successful comissioning on site. | ||||||
| 24 | C-1/1 | Supply of Main L.V Panels with PFI and Synchronization system (Form3B - Type 2 minimum). The scope comprehensively includes all necessary control cabling, an automation system featuring a remote monitoring synchronization module, a dedicated Microgrid Controller for PV system control, and an integrated HMI display module for real-time synchronization management. (Sync. Module must be COMAP) Note: -Refer Technical Specification Section V-05 (Annexure A) for control philosophy. -All Rigid Connection (Busbar links between Busway Flange and Panel) of following Busways are in Panel Builder Scope a- 1600A Main Incoming 1 b- 1600A Main Incoming 2 | No. | 1 | 32707602 | Rupees Thirty Two Million Seven Hundred Seven Thousand Six Hundred Two Only | 32707602 |
| 25 | C-1/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-1/1 | No. | 1 | 371142 | Rupees Three Hundred Seventy One Thousand One Hundred Forty Two Only | 371142 |
| 26 | C-2/1 | Supply of Genset LTO Panel with Synchronization system (Form3B - Type 2 minimum). The scope comprehensively includes all necessary control cabling, an automation system featuring a remote monitoring synchronization module, complete in all respects. (Sync. Module must be COMAP) | No. | 1 | 17963754 | Rupees Seventeen Million Nine Hundred Sixty Three Thousand Seven Hundred Fifty Four Only | 17963754 |
| 27 | C-2/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-2/1 | No. | 1 | 371142 | Rupees Three Hundred Seventy One Thousand One Hundred Forty Two Only | 371142 |
| 28 | C-3/1 | Supply of LT-5 PANEL (GF) | No. | 1 | 2890810 | Rupees Two Million Eight Hundred Ninety Thousand Eight Hundred Ten Only | 2890810 |
| 29 | C-3/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-3/1 | No. | 1 | 123714 | Rupees One Hundred Twenty Three Thousand Seven Hundred Fourteen Only | 123714 |
| 30 | C-4/1 | Supply of ELT-1 PANEL (GF) | No. | 1 | 1979336 | Rupees One Million Nine Hundred Seventy Nine Thousand Three Hundred Thirty Six Only | 1979336 |
| 31 | C-4/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-4/1 | No. | 1 | 123714 | Rupees One Hundred Twenty Three Thousand Seven Hundred Fourteen Only | 123714 |
| 32 | C-5/1 | Supply of EDB-1 (GF) | No. | 1 | 323458 | Rupees Three Hundred Twenty Three Thousand Four Hundred Fifty Eight Only | 323458 |
| 33 | C-5/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-5/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 34 | C-6/1 | Supply of DB-1 (GF) | No. | 1 | 414129 | Rupees Four Hundred Fourteen Thousand One Hundred Twenty Nine Only | 414129 |
| 35 | C-6/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-6/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 36 | C-7/1 | Supply of DB-AC (FF) | No. | 1 | 414745 | Rupees Four Hundred Fourteen Thousand Seven Hundred Forty Five Only | 414745 |
| 37 | C-7/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-7/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 38 | C-8/1 | Supply of EDB-4 (FF) | No. | 1 | 339734 | Rupees Three Hundred Thirty Nine Thousand Seven Hundred Thirty Four Only | 339734 |
| 39 | C-8/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-8/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 40 | C-9/1 | Supply of SLT-1 & DB-2 (FF) | No. | 1 | 646607 | Rupees Six Hundred Forty Six Thousand Six Hundred Seven Only | 646607 |
| 41 | C-9/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-9/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 42 | C-10/1 | Supply of SLT-2 & DB-5 (SF) | No. | 1 | 621186 | Rupees Six Hundred Twenty One Thousand One Hundred Eighty Six Only | 621186 |
| 43 | C-10/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-10/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 44 | C-11/1 | Supply of LPDB-SF (SF) | No. | 1 | 349495 | Rupees Three Hundred Forty Nine Thousand Four Hundred Ninety Five Only | 349495 |
| 45 | C-11/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-11/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 46 | C-12/1 | Supply of DB-HALL-1 (SF) | No. | 1 | 368872 | Rupees Three Hundred Sixty Eight Thousand Eight Hundred Seventy Two Only | 368872 |
| 47 | C-12/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-12/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 48 | C-13/1 | Supply of DB-HALL-2 (SF) | No. | 1 | 368872 | Rupees Three Hundred Sixty Eight Thousand Eight Hundred Seventy Two Only | 368872 |
| 49 | C-13/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-13/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 50 | C-14/1 | Supply of LPDB-SUB | No. | 1 | 312767 | Rupees Three Hundred Twelve Thousand Seven Hundred Sixty Seven Only | 312767 |
| 51 | C-14/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-14/1 | No. | 1 | 37115 | Rupees Thirty Seven Thousand One Hundred Fifteen Only | 37115 |
| 52 | C-15/1 | Supply of MCC Panel | No. | 1 | 8497748 | Rupees Eight Million Four Hundred Ninety Seven Thousand Seven Hundred Forty Eight Only | 8497748 |
| 53 | C-15/2 | Placement, Installation, Transportation, Loading/Unloading, Testing & Commissioning of above item at S.# C-15/1 | No. | 1 | 123714 | Rupees One Hundred Twenty Three Thousand Seven Hundred Fourteen Only | 123714 |
| 54 | C-16 | Physical Factory Acceptance Test at the manufacturer's premises for 2 Persons (1 No. Client's Representative & 1 No. Consultant's Representative with supplier) | Job | 1 | 30929 | Rupees Thirty Thousand Nine Hundred Twenty Nine Only | 30929 |
| 55 | Note: - The contractor shall provision and install temporary Distribution Board (DB) as required to minimize system downtime during the transition and swapping of existing units. | ||||||
| 56 | SECTION - D CENTRALIZED ENERGY MONITORING SYSTEM | ||||||
| 57 | Supply, Installation, Testing & Commissioning of complete Central Energy monitoring System, including with wiring, software, terminations, complete in all respect. Note: - Energy Analyzers with protocols like Modbus RTU/TCP, BACnet, and INCOM are already installed in the DBs. - Warranty period will start from the date of successful Testing & Commissioning | ||||||
| 58 | D-1/1 | IoT Gateway / Data Logger for transmission of energy analyzer data to server including housing (if required) | Job | 1 | 340971 | Rupees Three Hundred Forty Thousand Nine Hundred Seventy One Only | 340971 |
| 59 | D-1/2 | Installation, Testing & Commissioning of above item at S.# D-1/1 | Job | 1 | 72781 | Rupees Seventy Two Thousand Seven Hundred Eighty One Only | 72781 |
| 60 | D-2/1 | Software Interface with Complete Dashboard for live remote monitoring of all electrical and energy parameters as well as data logging of complete data. including 1 year license for all nodes from the date of successful commissioning of system. | Job | 1 | 968665 | Rupees Nine Hundred Sixty Eight Thousand Six Hundred Sixty Five Only | 968665 |
| 61 | D-2/2 | Installation, Testing & Commissioning of above item at S.# D-2/1 | Job | 1 | 27298 | Rupees Twenty Seven Thousand Two Hundred Ninety Eight Only | 27298 |
| 62 | D-3/1 | Workstation PC with complete accessories (if required for software installation / server set-up to be quoted by supplier as per their system requirement) | No. | 1 | 232484 | Rupees Two Hundred Thirty Two Thousand Four Hundred Eighty Four Only | 232484 |
| 63 | D-3/2 | Installation, Testing & Commissioning of above item at S.# D-3/1 | No. | 1 | 7281 | Rupees Seven Thousand Two Hundred Eighty One Only | 7281 |
| 64 | D-4/1 | Supply and Wiring for interconnecting from Energy Analyzer to Energy Analyzer with CAT-6 UTP 23 AWG in 25mm dia PVC conduit including all accessories Complete in all respect as per drawings and technical Specifications. | Rm | 150 | 851 | Rupees One Hundred Twenty Seven Thousand Six Hundred Fifty Only | 127650 |
| 65 | D-4/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# D-4/1 | Rm | 150 | 279 | Rupees Forty One Thousand Eight Hundred Fifty Only | 41850 |
| 66 | D-5 | Programming, testing and commissioning of complete system including on site demonstration and training of client's representative upto the entire satisfaction of consultant/client | Job | 1 | 247428 | Rupees Two Hundred Forty Seven Thousand Four Hundred Twenty Eight Only | 247428 |
| 67 | Note: - Contractor is advised to confirm the cable running lengths and termination as per site conditions before commencement of work. | ||||||
| 68 | SECTION - E MEDIUM VOLTAGE CABLES & TERMINATION KITS | ||||||
| 69 | Supply, Laying Termination, Testing and Commissioning of following 8.7/15kV, MV Cables in already installed Cable trench / Cable ladder / Cable tray / Duct Bank including all accessories. Complete in all respects as per drawing and specification. | ||||||
| 70 | E-1/1 | From MV Switch to 1000kVA Transformer # 1 3C-300 Sqmm 8.7/15kV AL/XLPE/PVC | Rm | 25 | 17378 | Rupees Four Hundred Thirty Four Thousand Four Hundred Fifty Only | 434450 |
| 71 | E-1/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# E-1/1 | Rm | 25 | 1807 | Rupees Forty Five Thousand One Hundred Seventy Five Only | 45175 |
| 72 | E-2/1 | From MV Switch to 1000kVA Transformer # 2 3C-300 Sqmm 8.7/15kV AL/XLPE/PVC | Rm | 25 | 17378 | Rupees Four Hundred Thirty Four Thousand Four Hundred Fifty Only | 434450 |
| 73 | E-2/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# E-2/1 | Rm | 25 | 1807 | Rupees Forty Five Thousand One Hundred Seventy Five Only | 45175 |
| 74 | E-3/1 | Supply, installation, testing and commissioning of 11KV, XLPE-AL, MV Cable Termination Kit at both ends with 3M, Raychem or equivalent approved brand termination kit etc. 3C-300 Sqmm Indoor Type MV Cable Termination kits with Boots including all termination accessories like HT tape etc. | No | 7 | 63324 | Rupees Four Hundred Forty Three Thousand Two Hundred Sixty Eight Only | 443268 |
| 75 | E-3/2 | Installation, Testing & Commissioning of above item at S.# E-3/1 | No | 7 | 24743 | Rupees One Hundred Seventy Three Thousand Two Hundred One Only | 173201 |
| 76 | E-4 | Physical Factory Acceptance Test at the manufacturer's premises for 2 Persons (1 No. Client's Representative & 1 No. Consultant's Representative with supplier) | Job | 1 | 30929 | Rupees Thirty Thousand Nine Hundred Twenty Nine Only | 30929 |
| 77 | Note: - Contractor is advised to confirm the cable running lengths and termination as per site conditions before commencement of work. - HIPOT Testing of MV Cables to be done by the Contractor. | ||||||
| 78 | SECTION - F LOW VOLTAGE CABLES | ||||||
| 79 | Supply, Laying, Termination, Testing & Commissioning of the following ratings of LV Cables along with complete installation and termination accessories to be laid in already installed Cable trench / Cable ladder / Cable tray / Duct Bank including all accessories. Complete in all respects. -Imported Bi-Mettalic Lugs and Connectors shall be used in LV Cables. -Manual crimping of lugs is not allowed. Proper lug presser for smaller lugs and hydraulic lug presser for large size lugs should be used. | ||||||
| 80 | F-1/1 | From 500kVA Generator to Generator Load Take-Off Panel 8 No. 1C-300 Sqmm Cu/PVC+ ECC 2 No. 1C-150 Sqmm Cu/PVC | Rm | 65 | 212334 | Rupees Thirteen Million Eight Hundred One Thousand Seven Hundred Ten Only | 13801710 |
| 81 | F-1/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-1/1 | Rm | 65 | 11209 | Rupees Seven Hundred Twenty Eight Thousand Five Hundred Eighty Five Only | 728585 |
| 82 | F-2/1 | From 600kVA Generator to Generator Load Take-Off Panel 12 No. 1C-240 Sqmm Cu/PVC+ ECC 3 No. 1C-120 Sqmm Cu/PVC | Rm | 55 | 254658 | Rupees Fourteen Million Six Thousand One Hundred Ninety Only | 14006190 |
| 83 | F-2/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-2/1 | Rm | 55 | 13442 | Rupees Seven Hundred Thirty Nine Thousand Three Hundred Ten Only | 739310 |
| 84 | F-3/1 | From 200kVA Generator to Generator Load Take-Off Panel 04 No. 1C-300 Sqmm Cu/PVC+ ECC 1 No. 1C-150 Sqmm Cu/PVC | Rm | 100 | 106170 | Rupees Ten Million Six Hundred Seventeen Thousand Only | 10617000 |
| 85 | F-3/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-3/1 | Rm | 100 | 5605 | Rupees Five Hundred Sixty Thousand Five Hundred Only | 560500 |
| 86 | F-4/1 | From Generator Load Take-off Panel O/G-1 to Main LV Panel 8 No. 1C-300 Sqmm Cu/PVC+ ECC 2 No. 1C-150 Sqmm Cu/PVC | Rm | 30 | 212334 | Rupees Six Million Three Hundred Seventy Thousand Twenty Only | 6370020 |
| 87 | F-4/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-4/1 | Rm | 30 | 11209 | Rupees Three Hundred Thirty Six Thousand Two Hundred Seventy Only | 336270 |
| 88 | F-5/1 | From Generator Load Take-off Panel O/G-2 to Main LV Panel 12 No. 1C-240 Sqmm Cu/PVC+ ECC 3 No. 1C-120 Sqmm Cu/PVC | Rm | 30 | 254658 | Rupees Seven Million Six Hundred Thirty Nine Thousand Seven Hundred Forty Only | 7639740 |
| 89 | F-5/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-5/1 | Rm | 30 | 13442 | Rupees Four Hundred Three Thousand Two Hundred Sixty Only | 403260 |
| 90 | F-6/1 | From Main LV Panel to LT-5 Panel (GF) 8 No. 1C-240 Sqmm Al/XLPE/PVC+ ECC 2 No. 1C-120 Sqmm Cu/PVC | Rm | 140 | 37250 | Rupees Five Million Two Hundred Fifteen Thousand Only | 5215000 |
| 91 | F-6/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-6/1 | Rm | 140 | 1968 | Rupees Two Hundred Seventy Five Thousand Five Hundred Twenty Only | 275520 |
| 92 | F-7/1 | From Main LV Panel to ELT-1 Panel (GF) 8 No. 1C-240 Sqmm Al/XLPE/PVC+ ECC 2 No. 1C-120 Sqmm Cu/PVC | Rm | 140 | 37250 | Rupees Five Million Two Hundred Fifteen Thousand Only | 5215000 |
| 93 | F-7/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-7/1 | Rm | 140 | 1968 | Rupees Two Hundred Seventy Five Thousand Five Hundred Twenty Only | 275520 |
| 94 | F-8/1 | From Main LV Panel to MCC Panel (Basement) 16 No. 1C-240 Sqmm Al/XLPE/PVC+ ECC 3 No. 1C-150 Sqmm Cu/PVC | Rm | 170 | 71608 | Rupees Twelve Million One Hundred Seventy Three Thousand Three Hundred Sixty Only | 12173360 |
| 95 | F-8/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-8/1 | Rm | 170 | 3780 | Rupees Six Hundred Forty Two Thousand Six Hundred Only | 642600 |
| 96 | F-9/1 | 4C-35 Sqmm Cu/PVC/PVC + 1C-16 Sqmm Cu/PVC | Rm | 50 | 11704 | Rupees Five Hundred Eighty Five Thousand Two Hundred Only | 585200 |
| 97 | F-9/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-9/1 | Rm | 50 | 1238 | Rupees Sixty One Thousand Nine Hundred Only | 61900 |
| 98 | F-10/1 | 4C-25 Sqmm Cu/PVC/PVC + 1C-16 Sqmm Cu/PVC | Rm | 50 | 8833 | Rupees Four Hundred Forty One Thousand Six Hundred Fifty Only | 441650 |
| 99 | F-10/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-10/1 | Rm | 50 | 935 | Rupees Forty Six Thousand Seven Hundred Fifty Only | 46750 |
| 100 | F-11/1 | 4C-16 Sqmm Cu/PVC/PVC + 1C-16 Sqmm Cu/PVC | Rm | 50 | 6097 | Rupees Three Hundred Four Thousand Eight Hundred Fifty Only | 304850 |
| 101 | F-11/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-11/1 | Rm | 50 | 644 | Rupees Thirty Two Thousand Two Hundred Only | 32200 |
| 102 | F-12/1 | 4C-10 Sqmm Cu/PVC/PVC + 1C-10 Sqmm Cu/PVC | Rm | 50 | 4124 | Rupees Two Hundred Six Thousand Two Hundred Only | 206200 |
| 103 | F-12/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-12/1 | Rm | 50 | 440 | Rupees Twenty Two Thousand Only | 22000 |
| 104 | F-13/1 | 2.5 Sqmm Cu/PVC (Red & Black coil for temporary works) | Rm | 50 | 215 | Rupees Ten Thousand Seven Hundred Fifty Only | 10750 |
| 105 | F-13/2 | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# F-13/1 | Rm | 50 | 25 | Rupees One Thousand Two Hundred Fifty Only | 1250 |
| 106 | F-14 | Supply and installation of Heat Shrinkable Straight-Through Jointing Kits suitable for 0.6/1kV or 11kV (as per site requirement) XLPE/PVC insulated, armored/unarmored power cables. Includes high-conductivity tinned copper/aluminum ferrules (as per conductor material), stress control tubing, adhesive-lined outer sealing sleeve, and earth continuity braid with constant force springs. The kits must be designed to provide a complete moisture-proof seal and mechanical protection equivalent to the original cable sheath. Complete in all respects. | |||||
| 107 | F-14/1 | 4C-300 sq.mm | Job | 1 | 40962 | Rupees Forty Thousand Nine Hundred Sixty Two Only | 40962 |
| 108 | F-14/1A | Installation, Testing & Commissioning of above item at S.# F-14/1 | Job | 1 | 6186 | Rupees Six Thousand One Hundred Eighty Six Only | 6186 |
| 109 | F-14/2 | 4C-240 sq.mm | Job | 1 | 40962 | Rupees Forty Thousand Nine Hundred Sixty Two Only | 40962 |
| 110 | F-14/2A | Installation, Testing & Commissioning of above item at S.# F-14/2 | Job | 1 | 6186 | Rupees Six Thousand One Hundred Eighty Six Only | 6186 |
| 111 | F-14/3 | 4C-35 sq.mm | Job | 1 | 24524 | Rupees Twenty Four Thousand Five Hundred Twenty Four Only | 24524 |
| 112 | F-14/3A | Installation, Testing & Commissioning of above item at S.# F-14/3 | Job | 1 | 3712 | Rupees Three Thousand Seven Hundred Twelve Only | 3712 |
| 113 | F-14/4 | 4C-25 sq.mm | Job | 1 | 24524 | Rupees Twenty Four Thousand Five Hundred Twenty Four Only | 24524 |
| 114 | F-14/4A | Installation, Testing & Commissioning of above item at S.# F-14/4 | Job | 1 | 3712 | Rupees Three Thousand Seven Hundred Twelve Only | 3712 |
| 115 | F-14/5 | 4C-16 sq.mm | Job | 1 | 13797 | Rupees Thirteen Thousand Seven Hundred Ninety Seven Only | 13797 |
| 116 | F-14/5A | Installation, Testing & Commissioning of above item at S.# F-14/5 | Job | 1 | 2475 | Rupees Two Thousand Four Hundred Seventy Five Only | 2475 |
| 117 | F-15 | Physical Factory Acceptance Test at the manufacturer's premises for 2 Persons (1 No. Client's Representative & 1 No. Consultant's Representative with supplier) | Job | 1 | 30929 | Rupees Thirty Thousand Nine Hundred Twenty Nine Only | 30929 |
| 118 | Note: - Contractor is instructed to confirm the cable running lengths and termination as per site conditions before commencement of work. - Imported Lugs and Connectors shall be used in LV Cables. - Megger Test of all LV Cables to be done by contractor. | ||||||
| 119 | SECTION - G CABLE CONTAINMENT | ||||||
| 120 | G-1 | Supply & Laying of following sizes of UPVC pipe sleeves embedded under the floor/slab, including all necessary couplers, solvent cement, end bells, and termination accessories, to form smooth cable routing paths connecting various handholes/manholes; including necessary excavation, trenching, backfilling, compacting, and installation of a 2mm galvanized steel draw wire inside each sleeve for future cable pulling. Provide Handhole where ever required. Note: The below mentioned conduits will be used for items where description of the item clearly states that the conduit is not inclusive or already laid/installed. This section will also cover empty conduit runs, sleeves, conduit risers etc. | |||||
| 121 | G-1/1 | 150mm dia UPVC Conduit (Class-D) | Rm. | 600 | 7857 | Rupees Four Million Seven Hundred Fourteen Thousand Two Hundred Only | 4714200 |
| 122 | G-1/1a | Laying, Installation, Testing & Commissioning of above item at S.# G-1/1 | Rm. | 600 | 829 | Rupees Four Hundred Ninety Seven Thousand Four Hundred Only | 497400 |
| 123 | G-2 | Making of RCC Handhole 600mm x 600mm x 900mm internal size, made with 150 mm thick Fiber walls and 200mm thick bed & top slabs, including cost of heavy duty 450mm square cover & angle iron frame (made 2”x2”x1/4” size angle iron) complete in all respects as per site requirements, as per drawing & details and as directed by the consultant. | No. | 10 | 92786 | Rupees Nine Hundred Twenty Seven Thousand Eight Hundred Sixty Only | 927860 |
| 124 | G-3 | Supply and Installation of following sizes G.I Powder Coated Perforated Cable Tray with 4 feet covers duly Painted after degreesing, derusting, phosphating and antirust primer complete in all respect with supporting hangers, brackets, elbows, tee & mounting accessories etc. Note: - Color Printed Tags to be provided at every 3 Meter Length. - Threaded Rods & Base Plate to be used for hanging from ceiling. - Wall Hanger Supports to be provided moving with walls. - U-shaped fischer plates to be used for joints. - Earth bonding to be done with every joint using flexible braided copper. - Color to be decided with consent of client. - Imported mounting accessories to be used make mungo or fischer. | |||||
| 125 | G-3/1 | 450mm x 100mm (16 SWG Tray and 18 SWG Cover) With Accessories (Power Cables) | Rm. | 40 | 11657 | Rupees Four Hundred Sixty Six Thousand Two Hundred Eighty Only | 466280 |
| 126 | G-3/1a | Installation, Testing & Commissioning of above item at S.# G-3/1 | Rm. | 40 | 1485 | Rupees Fifty Nine Thousand Four Hundred Only | 59400 |
| 127 | G-3/2 | 300mm x 100mm (16 SWG Tray and 18 SWG Cover) With Accessories (Power Cables) | Rm. | 100 | 8707 | Rupees Eight Hundred Seventy Thousand Seven Hundred Only | 870700 |
| 128 | G-3/2a | Installation, Testing & Commissioning of above item at S.# G-3/2 | Rm. | 100 | 1485 | Rupees One Hundred Forty Eight Thousand Five Hundred Only | 148500 |
| 129 | Note: Contractor is advised to confirm the sizes, running lengths and termination as per site conditions before commencement of work. | ||||||
| 130 | SECTION - H ENCLOSED BUS ASSEMBLIES | ||||||
| 131 | Supply, Installation, Testing and Commissioning must be included in quoted price of the following imported TP+N+E Compact Busway including imported accessories like elbows, flange ends, U Shape supporting hangers, mounting accessories, complete in all respects and having attached specifications. Material : Aluminium Type : Compact Note: - The contract will be on item rate basis, therefore amount for only items being used at site will be paid. - Separate earth bar on 100% (50% Housing + 50% Bar) is required for all busways. - Expansion joints for straight length feeders shall be added in cost as per manufacturer standard without any additional cost. - All Power Busway shall be Sandwich Type. - All Power Busway shall be IP-65 and IK-09 rated. - All type test certificates are required; site tests shall be carried out in accordance with the provided specifications. - Supplier is advised to confirm the busway running lengths as per site conditions before final ordering to the principal. - Bidder shall submit the shop drawings with isometric views in hard copy and soft copy as well. - All the mounting heights have been mentioned in drawings. - Installation will include hangers and other accessories like hanging rods,rawal bolts etc. - Client will not arrange the site security particularly for the material & equipment till its final erection. It will be vendor responsibility. - All Busway lengths will be measured from End to End excluding the Elbows, Flanges, Flexibles etc. '- Copper connection between Breaker and Flange shall be included as mentioned below. - Expansion joints for straight length feeders shall be added in cost as per manufacturer standard without any additional cost. - Flexible connections on straight lengths as per manufacturer's recommendation shall be provided as inclusive in the cost of busways. - Spring Hangers for Earth Quake sustainability on all vertical busways shall be included in the above mentioned cost. | ||||||
| 132 | H-1 | Busway-Main (IP-65 Rated, 1600A TP+N+E) for Main Incoming 1 Location: From Transformer 1 to LV Panel | |||||
| 133 | H-1/1 | Straight Lengths 1600A TP+N+E (5 Bar) | Rm. | 30 | 133502 | Rupees Four Million Five Thousand Sixty Only | 4005060 |
| 134 | H-1/1a | Installation, Testing & Commissioning of above item at S.# H-1/1 | Rm. | 30 | 7058 | Rupees Two Hundred Eleven Thousand Seven Hundred Forty Only | 211740 |
| 135 | H-1/2 | Elbow 1600A | No. | 3 | 96884 | Rupees Two Hundred Ninety Thousand Six Hundred Fifty Two Only | 290652 |
| 136 | H-1/2a | Installation, Testing & Commissioning of above item at S.# H-1/2 | No. | 3 | 5122 | Rupees Fifteen Thousand Three Hundred Sixty Six Only | 15366 |
| 137 | H-1/3 | Flange for LV Panel Connection | No. | 1 | 87587 | Rupees Eighty Seven Thousand Five Hundred Eighty Seven Only | 87587 |
| 138 | H-1/3a | Installation, Testing & Commissioning of above item at S.# H-1/3 | No. | 1 | 4634 | Rupees Four Thousand Six Hundred Thirty Four Only | 4634 |
| 139 | H-1/4 | Flange for Transformer Connection | No. | 1 | 87587 | Rupees Eighty Seven Thousand Five Hundred Eighty Seven Only | 87587 |
| 140 | H-1/4a | Installation, Testing & Commissioning of above item at S.# H-1/4 | No. | 1 | 4634 | Rupees Four Thousand Six Hundred Thirty Four Only | 4634 |
| 141 | H-1/5 | Flexible Connection (Insulated Braided Copper) 1600A TP+N+E (Busbar links between Flange and Transformer) | No. | 1 | 464962 | Rupees Four Hundred Sixty Four Thousand Nine Hundred Sixty Two Only | 464962 |
| 142 | H-1/5a | Installation, Testing & Commissioning of above item at S.# H-1/5 | No. | 1 | 24570 | Rupees Twenty Four Thousand Five Hundred Seventy Only | 24570 |
| 143 | H-1/6 | Imported Galvanized Fixing Bracket with threaded rods, bolts and all other required accessories. | Job | 1 | 48964 | Rupees Forty Eight Thousand Nine Hundred Sixty Four Only | 48964 |
| 144 | H-1/6a | Installation, Testing & Commissioning of above item at S.# H-1/6 | Job | 1 | 2592 | Rupees Two Thousand Five Hundred Ninety Two Only | 2592 |
| 145 | H-2 | Busway-Main (IP-65 Rated, 1600A TP+N+E) for Main Incoming 2 Location: From Transformer 2 to LV Panel | |||||
| 146 | H-2/1 | Straight Lengths 1600A TP+N+E (5 Bar) | Rm. | 30 | 133502 | Rupees Four Million Five Thousand Sixty Only | 4005060 |
| 147 | H-2/1a | Installation, Testing & Commissioning of above item at S.# H-2/1 | Rm. | 30 | 7058 | Rupees Two Hundred Eleven Thousand Seven Hundred Forty Only | 211740 |
| 148 | H-2/2 | Elbow 1600A | No. | 3 | 96884 | Rupees Two Hundred Ninety Thousand Six Hundred Fifty Two Only | 290652 |
| 149 | H-2/2a | Installation, Testing & Commissioning of above item at S.# H-2/2 | No. | 3 | 5122 | Rupees Fifteen Thousand Three Hundred Sixty Six Only | 15366 |
| 150 | H-2/3 | Flange for LV Panel Connection | No. | 1 | 87587 | Rupees Eighty Seven Thousand Five Hundred Eighty Seven Only | 87587 |
| 151 | H-2/3a | Installation, Testing & Commissioning of above item at S.# H-2/3 | No. | 1 | 4634 | Rupees Four Thousand Six Hundred Thirty Four Only | 4634 |
| 152 | H-2/4 | Flange for Transformer Connection | No. | 1 | 87587 | Rupees Eighty Seven Thousand Five Hundred Eighty Seven Only | 87587 |
| 153 | H-2/4a | Installation, Testing & Commissioning of above item at S.# H-2/4 | No. | 1 | 4634 | Rupees Four Thousand Six Hundred Thirty Four Only | 4634 |
| 154 | H-2/5 | Flexible Connection (Insulated Braided Copper) 1600A TP+N+E (Busbar links between Flange and Transformer) | No. | 1 | 464962 | Rupees Four Hundred Sixty Four Thousand Nine Hundred Sixty Two Only | 464962 |
| 155 | H-2/5a | Installation, Testing & Commissioning of above item at S.# H-2/5 | No. | 1 | 24570 | Rupees Twenty Four Thousand Five Hundred Seventy Only | 24570 |
| 156 | H-2/6 | Imported Galvanized Fixing Bracket with threaded rods, bolts and all other required accessories. | Job | 1 | 48964 | Rupees Forty Eight Thousand Nine Hundred Sixty Four Only | 48964 |
| 157 | H-2/6a | Installation, Testing & Commissioning of above item at S.# H-2/6 | Job | 1 | 2592 | Rupees Two Thousand Five Hundred Ninety Two Only | 2592 |
| 158 | H-3 | Transportation, Loading & Unloading, Placement and Storing material at site | Job | 1 | 61857 | Rupees Sixty One Thousand Eight Hundred Fifty Seven Only | 61857 |
| 159 | SECTION - I IMPORTED EARTHING / GROUNDING SYSTEM | ||||||
| 160 | Supply, Installation, Testing & Commissioning of the following items required for Earthing, Lightning Protection and Grounding of other systems including all material, boring, labor, tools, transportation, installation accessories etc. Complete in all respects as per drawings and specifications. - The contractor will also submit detailed earth test reports for approval. | ||||||
| 161 | I-1/1 | Chemical Enhanced Earth using 20mm dia, 10ft long imported copper cladded steel Rod filled with soil conditioning material including 6" dia, 11' deep boring and back filled chemical to enhance conductivity. Complete with termination clamps, 12" dia heavy duty tin plated round cover as per details given in drawings. | No. | 14 | 104855 | Rupees One Million Four Hundred Sixty Seven Thousand Nine Hundred Seventy Only | 1467970 |
| 162 | I-1/2 | Installation, Testing & Commissioning of above item at S.# I-1/1 | No. | 14 | 24743 | Rupees Three Hundred Forty Six Thousand Four Hundred Two Only | 346402 |
| 163 | I-2/1 | Earth Connecting Point (ECP) or Equipotential bar made with 450 mm wide, 75 mm high and 5 mm thick tin plated Copper, as shown in drawings. Bar shall be provided with holes suitable for installation of 6 No. 95 sqmm bare copper conductor. ECP shall be enclosed in appropriate size of powder coated metal enclosure with front accessible cover. | No. | 20 | 49371 | Rupees Nine Hundred Eighty Seven Thousand Four Hundred Twenty Only | 987420 |
| 164 | I-2/2 | Installation, Testing & Commissioning of above item at S.# I-2/1 | No. | 20 | 3712 | Rupees Seventy Four Thousand Two Hundred Forty Only | 74240 |
| 165 | I-3 | Stranded bare copper conductors of the following sizes in 38mm dia UPVC Class-D conduit to be laid in floor/raft from Earth Station to ECP as shown in drawings. Complete in all respects including termination at ECP. | |||||
| 166 | I-3/1 | 95 Sqmm Bare Copper Conductor | Rm. | 400 | 6599 | Rupees Two Million Six Hundred Thirty Nine Thousand Six Hundred Only | 2639600 |
| 167 | I-3/1a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# I-3/1 | Rm. | 400 | 693 | Rupees Two Hundred Seventy Seven Thousand Two Hundred Only | 277200 |
| 168 | I-4 | Supply, installation, testing & commissioning of following size of single core PVC cables in appropriate size of exposed / concelled conduit from ECP to several equipments as per details given below, including all material, labor, tools, transportation, accessories etc. Complete in all respects with detailed test reports. | |||||
| 169 | I-4/1 | 1C-95 Sqmm Cu/PVC | Rm. | 50 | 6672 | Rupees Three Hundred Thirty Three Thousand Six Hundred Only | 333600 |
| 170 | I-4/1a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# I-4/1 | Rm. | 50 | 699 | Rupees Thirty Four Thousand Nine Hundred Fifty Only | 34950 |
| 171 | I-4/2 | 1C-70 Sqmm Cu/PVC | Rm. | 50 | 6014 | Rupees Three Hundred Thousand Seven Hundred Only | 300700 |
| 172 | I-4/2a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# I-4/2 | Rm. | 50 | 631 | Rupees Thirty One Thousand Five Hundred Fifty Only | 31550 |
| 173 | I-4/3 | 1C-35 Sqmm Cu/PVC | Rm. | 50 | 3080 | Rupees One Hundred Fifty Four Thousand Only | 154000 |
| 174 | I-4/3a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# I-4/3 | Rm. | 50 | 328 | Rupees Sixteen Thousand Four Hundred Only | 16400 |
| 175 | Note: - Contractor is advised to confirm the cable running lengths and termination as per site conditions before commencement of work. - The bidder shall submit complete technical literature of the quoted system for approval before procurement. | ||||||
| 176 | SECTION - J SUBSTATION ELECTRIFICATION | ||||||
| 177 | J-1 | Supply, Installation, Testing & Commissioning of the following wiring items including all material, labour & tools required for completion of work as per item description, specifications & drawings including cutting, chiseling, making good and all necessary accessories such as bends, junction boxes, conduit sockets, earth connecting point connectors, etc. as shown on drawings, specifications and approval by the Engineer. Complete in all respects. Note: 1) The cost of wiring items shall includes Imported Polycarbonate Connectors and High Quality flexible PVC conduit as per LOAM of appropriate size on each light point. 2) Insulation Resistance Test of each circuit to be done by the Contractor. 3) All General Wiring grade should be 450/750 copper. 4) Surface conduiting shall be done in decorative / aesthetic manner. 5) Wherever the circuits are running in cable tray, it will enter / leave tray using proper PVC glands / Junction boxes (IP44). The cost of all such accessories to be included in wiring cost. 6) All electrical circuits and power outlets shall be numbered (i.e. circuit number and distribution board number shall be printed). 7) Contractor is advised to confirm the cable running lengths and termination as per site conditions before commencement of work. 8) All the cables shall be colour coded according to phases / types of services. | |||||
| 178 | J-1/1 | Circuit wiring from DB to Switchboard including any wiring from switch board to switch board with 2x2.5 Sq.mm + ECC 1x2.5 Sqmm, Cu/PVC wires in 25mm dia PVC conduit as shown in drawings. | No | 2 | 14329 | Rupees Twenty Eight Thousand Six Hundred Fifty Eight Only | 28658 |
| 179 | J-1/1a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/1 | No | 2 | 1485 | Rupees Two Thousand Nine Hundred Seventy Only | 2970 |
| 180 | J-1/1b | Wiring for light point from Switchboard to first light point with phase 2.5 Sq.mm, common neutral 2.5 Sq.mm and common ECC 2.5 Sq.mm, Cu/PVC wires in 25mm dia PVC conduit as shown on drawings. | No | 15 | 7168 | Rupees One Hundred Seven Thousand Five Hundred Twenty Only | 107520 |
| 181 | J-1/1c | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/1b | No | 15 | 743 | Rupees Eleven Thousand One Hundred Forty Five Only | 11145 |
| 182 | J-1/1d | Point to Point wiring with phase 1.5 Sq.mm, common neutral 2.5 Sq.mm and common ECC 2.5 Sq.mm Cu/PVC in 25mm dia PVC conduit as shown in drawings. | No | 5 | 3169 | Rupees Fifteen Thousand Eight Hundred Forty Five Only | 15845 |
| 183 | J-1/1e | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/1d | No | 5 | 335 | Rupees One Thousand Six Hundred Seventy Five Only | 1675 |
| 184 | J-1/2 | Wiring for Group Control light fixtures from DB to first light point with 2x1.5 Sq.mm + ECC 1x1.5 Sq.mm Cu/PVC wires in 25mm dia PVC conduit as shown on drawings. | No | 1 | 7011 | Rupees Seven Thousand Eleven Only | 7011 |
| 185 | J-1/2a | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/2 | No | 1 | 737 | Rupees Seven Hundred Thirty Seven Only | 737 |
| 186 | J-1/2b | Point to Point wiring using the same wires & conduit size as mentioned in the above item. | No | 5 | 4672 | Rupees Twenty Three Thousand Three Hundred Sixty Only | 23360 |
| 187 | J-1/2c | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/2b | No | 5 | 495 | Rupees Two Thousand Four Hundred Seventy Five Only | 2475 |
| 188 | J-1/3 | Circuit Wiring of 13A/15A Switch Socket units (RAW Power) from DB to first outlet including wiring within same technology box / adjacent power outlets in separate back boxes with following size of 1-core wires in 25mm dia of PVC conduits as shown in the drawings. | |||||
| 189 | J-1/3a | 2 x 4 Sq.mm Cu/PVC + ECC 1 x 4 Sq.mm Cu/PVC | No | 4 | 15875 | Rupees Sixty Three Thousand Five Hundred Only | 63500 |
| 190 | J-1/3b | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/3a | No | 4 | 1640 | Rupees Six Thousand Five Hundred Sixty Only | 6560 |
| 191 | J-1/3c | Outlet to Outlet wiring including adjacent outlet wiring using 3 x 2.5 Sqmm Cu/PVC wires & in 25mm dia PVC conduit as mentioned in the drawings. | No | 22 | 5158 | Rupees One Hundred Thirteen Thousand Four Hundred Seventy Six Only | 113476 |
| 192 | J-1/3d | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/3c | No | 22 | 526 | Rupees Eleven Thousand Five Hundred Seventy Two Only | 11572 |
| 193 | J-1/4 | Circuit Wiring of 4 TON Floor Standing Air Conditioner from DB to equipment with following size of wires in 25mm dia size of exposed / concealed PVC conduit as shown on drawings. | |||||
| 194 | J-1/4a | 2 x 4 Sq.mm Cu/PVC + ECC 1 x 4 Sq.mm Cu/PVC | No | 1 | 21168 | Rupees Twenty One Thousand One Hundred Sixty Eight Only | 21168 |
| 195 | J-1/4b | Laying, Tagging, Termination, Testing & Commissioning of above item at S.# J-1/4a | No | 1 | 2184 | Rupees Two Thousand One Hundred Eighty Four Only | 2184 |
| 196 | J-2 | Supply & Laying of the following sizes of PVC/UPVC/EMT Conduits including all accessories such as bends, sockets, j-boxes, flexible conduits, metal saddles e.t.c as per design drawings, complete in all respect. | |||||
| 197 | J-2/1 | 25mm dia PVC Conduit | Rm | 100 | 220 | Rupees Twenty Two Thousand Only | 22000 |
| 198 | J-2/1a | Installation, Testing & Commissioning of above item at S.# J-2/1 | Rm | 100 | 25 | Rupees Two Thousand Five Hundred Only | 2500 |
| 199 | J-2/2 | 38mm dia UPVC Conduit (Class-D) | Rm | 100 | 700 | Rupees Seventy Thousand Only | 70000 |
| 200 | J-2/2a | Installation, Testing & Commissioning of above item at S.# J-2/2 | Rm | 100 | 75 | Rupees Seven Thousand Five Hundred Only | 7500 |
| 201 | J-3/1 | Supply & Installation of 16 SWG MS Sheet Steel Back Boxes for installation of Switches, Sockets, Voice & Data Outlets, Isolators as per drawings and details including all accessories. | Rm | 35 | 449 | Rupees Fifteen Thousand Seven Hundred Fifteen Only | 15715 |
| 202 | J-3/2 | Installation, Testing & Commissioning of above item at S.# J-3/1 | Rm | 35 | 50 | Rupees One Thousand Seven Hundred Fifty Only | 1750 |
| 203 | J-4 | Supply and installation of following sizes 16 SWG Galvanized Cable Ladder with 16 SWG G.I Cover as per details given in the drawings and specifications with prime quality japanese standard JIS 3302 36-38 microns Galvanized iron steel in line with NEMA standards with min. 36 microns Zinc overlap coating. Complete with all supporting hangers, brackets, elbows, tee & mounting accessories etc. Note: - Color Printed Tags to be provided at every 3 Meter Length. - Threaded Rods & Base Plate to be used for hanging from ceiling & vertical accessories. - Wall Hanger Supports to be provided moving with walls. - U-shaped fischer plates to be used for joints. - Earth bonding to be done with every joint using flexible braided copper. - Imported mounting accessories to be used make mungo or fischer. | |||||
| 204 | J-4/1 | 300mm x 100mm (MV Cable) | Rm. | 40 | 8504 | Rupees Three Hundred Forty Thousand One Hundred Sixty Only | 340160 |
| 205 | J-4/1a | Installation, Testing & Commissioning of above item at S.# J-4/1 | Rm. | 40 | 1238 | Rupees Forty Nine Thousand Five Hundred Twenty Only | 49520 |
| 206 | J-5 | Supply & Installation of following Switches and socket outlets recessed / surface on wall or as per design drawings. Following makes and models are suggested in white color but the final recommendation and approval to be given by the Architect on physical samples. Switches: Schneider Vivace, Legrand Eloe, or approved equiv. Sockets : Schneider Vivace Legrand Eloe, or approved equiv. Isolators : Schneider, Gewiss, Walther Industrial Sockets : Schneider, Gewiss, Walther, PCE | |||||
| 207 | J-5/1 | One Gang Light Switch | No | 1 | 1097 | Rupees One Thousand Ninety Seven Only | 1097 |
| 208 | J-5/1a | Installation, Testing & Commissioning of above item at S.# J-5/1 | No | 1 | 433 | Rupees Four Hundred Thirty Three Only | 433 |
| 209 | J-5/2 | Two Gang Light Switch | No | 1 | 1655 | Rupees One Thousand Six Hundred Fifty Five Only | 1655 |
| 210 | J-5/2a | Installation, Testing & Commissioning of above item at S.# J-5/2 | No | 1 | 433 | Rupees Four Hundred Thirty Three Only | 433 |
| 211 | J-5/3 | Three Gang Light Switch | No | 4 | 2600 | Rupees Ten Thousand Four Hundred Only | 10400 |
| 212 | J-5/3a | Installation, Testing & Commissioning of above item at S.# J-5/3 | No | 4 | 433 | Rupees One Thousand Seven Hundred Thirty Two Only | 1732 |
| 213 | J-5/4 | 13A, International Switch Socket Unit | No | 13 | 2772 | Rupees Thirty Six Thousand Thirty Six Only | 36036 |
| 214 | J-5/4a | Installation, Testing & Commissioning of above item at S.# J-5/4 | No | 13 | 433 | Rupees Five Thousand Six Hundred Twenty Nine Only | 5629 |
| 215 | J-5/5 | 15A 3-Pin Round Switch Socket unit | No | 13 | 2772 | Rupees Thirty Six Thousand Thirty Six Only | 36036 |
| 216 | J-5/5a | Installation, Testing & Commissioning of above item at S.# J-5/5 | No | 13 | 433 | Rupees Five Thousand Six Hundred Twenty Nine Only | 5629 |
| 217 | J-5/6 | 32A DP Isolator | No | 1 | 14194 | Rupees Fourteen Thousand One Hundred Ninety Four Only | 14194 |
| 218 | J-5/6a | Installation, Testing & Commissioning of above item at S.# J-5/6 | No | 1 | 743 | Rupees Seven Hundred Forty Three Only | 743 |
| 219 | J-5/7 | 16A 3-Pin (Single Phase) Industrial Socket with Plug | No | 1 | 3910 | Rupees Three Thousand Nine Hundred Ten Only | 3910 |
| 220 | J-5/7a | Installation, Testing & Commissioning of above item at S.# J-5/7 | No | 1 | 1238 | Rupees One Thousand Two Hundred Thirty Eight Only | 1238 |
| 221 | J-5/8 | 32A 3-Pin (Single Phase) Industrial Socket with Plug | No | 1 | 6197 | Rupees Six Thousand One Hundred Ninety Seven Only | 6197 |
| 222 | J-5/8a | Installation, Testing & Commissioning of above item at S.# J-5/8 | No | 1 | 1238 | Rupees One Thousand Two Hundred Thirty Eight Only | 1238 |
| 223 | J-6 | Supply, Installation, Testing & Commissioning of the following Light fixtures complete with the supply of all hanging accessories including clips, suspension rods / wires, ceiling frame etc. | |||||
| 224 | J-6/1 | Wall/Surface Mounted 18W LED Batten Light Fixture, 4000K, L=1200mm | No. | 20 | 3952 | Rupees Seventy Nine Thousand Forty Only | 79040 |
| 225 | J-6/1a | Installation, Testing & Commissioning of above item at S.# J-6/1 | No. | 20 | 749 | Rupees Fourteen Thousand Nine Hundred Eighty Only | 14980 |
| 226 | J-6/2 | NON-MAINTAINED TYPE WALL MOUNT EMERGENCY LIGHT WITH 5W LED LAMP AND 1.5 HOUR BUILT-IN BATTERY BACK-UP | No. | 6 | 24101 | Rupees One Hundred Forty Four Thousand Six Hundred Six Only | 144606 |
| 227 | J-6/2a | Installation, Testing & Commissioning of above item at S.# J-6/2 | No. | 6 | 749 | Rupees Four Thousand Four Hundred Ninety Four Only | 4494 |
| 228 | SECTION - K MISC. WORKS | ||||||
| 229 | K-1 | Preparation & Submission of As-Built drawings for all electrical and allied works after getting final approval from the Client/Consultant. Note: 2 sets of as-built drawings after work completion of each floor, and 3 sets with a soft copy of complete electrical works after final commissioning of project to be submitted. Approval of bills are subject to the completion of as built drawings upto the entire satisfaction ot site engineer. | Job | 1 | 110106 | Rupees One Hundred Ten Thousand One Hundred Six Only | 110106 |
| 230 | K-2 | Disconnection, professional rigging, craneage, and transportation of the existing 200kVA Diesel Generator from the substation to the new outdoor location. This item includes the construction of a reinforced concrete (RCC) foundation pad with vibration isolators and the provision of a 110% capacity fuel/oil spill containment bund. The scope covers all mechanical and electrical re-connections, cable containment, and full testing and commissioning, ensuring the system is complete in all respects. | Job | 1 | 556713 | Rupees Five Hundred Fifty Six Thousand Seven Hundred Thirteen Only | 556713 |
| 231 | K-3 | Supply and installation of an IP-rated acoustic weather-proof canopy for the existing 200kVA Diesel Generator. The item includes all necessary mounting, sealing, and integration with the generator unit to ensure protection against environmental factors and compliance with noise reduction requirements, complete in all respects. | Job | 1 | 618570 | Rupees Six Hundred Eighteen Thousand Five Hundred Seventy Only | 618570 |
| 232 | K-4 | Disconnection, professional rigging, craneage, and transportation of the existing 2,400-liter fuel storage tank to the designated new location. Item includes the construction of a heavy-duty reinforced concrete (RCC) foundation pad and a 110% capacity secondary fuel/oil spill containment bund (dyke wall) to comply with environmental safety standards. Scope covers the relocation, modification, and extension of all fuel supply, return, and vent piping, including the re-installation of all valves, strainers, and level sensing equipment. Work includes all mechanical/electrical integration, earth bonding, and comprehensive pressure and leak testing of the entire fuel delivery system. Complete in all respects as per job requirements or as directed by the Engineer. | Job | 1 | 742284 | Rupees Seven Hundred Forty Two Thousand Two Hundred Eighty Four Only | 742284 |
| 233 | K-5 | Dismantling/pulling/removal, loading, shifting, unloading and transportation to SBP Store of existing Consumer MV Switchgears including with all required materials, equipment, machines, removal of any debris etc. related to complete the job. Complete in all respects as per job requirements or as directed by the Engineer / as per Client instructions. Notes: 1) Contractor has been advised to make a detailed site visit for this job. 2) Contractor shall handover all dismantled items to SBP Store with signed inventory. 3) A clearly marked plan to be prepared for dismantling / disconnection work by the contractor for approval of consultant / client before commencement of work. | Job | 1 | 309285 | Rupees Three Hundred Nine Thousand Two Hundred Eighty Five Only | 309285 |
| 234 | K-6 | Dismantling/pulling/removal, loading, shifting, unloading and transportation to SBP Store of existing 02 Nos Transfomers including with all required materials, equipment, machines, removal of any debris etc. related to complete the job. Complete in all respects as per job requirements or as directed by the Engineer / as per Client instructions. Notes: 1) Contractor has been advised to make a detailed site visit for this job. 2) Contractor shall handover all dismantled items to SBP Store with signed inventory. 3) A clearly marked plan to be prepared for dismantling / disconnection work by the contractor for approval of consultant / client before commencement of work. | Job | 1 | 371142 | Rupees Three Hundred Seventy One Thousand One Hundred Forty Two Only | 371142 |
| 235 | K-7 | Dismantling/pulling/removal, loading, shifting, unloading and transportation to SBP Store of existing Main LV Panels and Distribution Boards (DBs) shall include a comprehensive technical execution plan where the contractor performs systematic tracing and tagging of all incoming and outgoing feeders using permanent, legible identifiers prior to any disconnection. This process must be supported by a detailed re-termination and interconnection schedule, including a clearly marked plan for cable re-routing to ensure seamless integration into the new LV panels. The scope further encompasses the safe disconnection and pulling of all power and control cables from existing ducts or trays, the physical removal of panel structures, and all associated logistics including loading, shifting, and transportation of dismantled components to the SBP Store, followed by the complete disposal of electrical debris and site clearance as directed by the Consultant and Client. | Job | 1 | 371142 | Rupees Three Hundred Seventy One Thousand One Hundred Forty Two Only | 371142 |
| 236 | K-8 | Arrangment of temporary cables and installation, connection to energize the system during dismantling and shifting of MV Switches to avoid shutdowns and to provide smooth power supply to building. Work also includes temporary site facilities, required materials & equipments to complete the job as per job requirements / directed by the Engineer / Client instructions. Complete in all respects to maintain zero downtime. | Job | 1 | 309285 | Rupees Three Hundred Nine Thousand Two Hundred Eighty Five Only | 309285 |
| 237 | K-9 | Arrangment of temporary cables and installation, connection to energize the system during dismantling and shifting of Transformers to avoid shutdowns and to provide smooth power supply to building. Work also includes temporary site facilities, required materials & equipments to complete the job as per job requirements / directed by the Engineer / Client instructions. Complete in all respects to maintain zero downtime. | Job | 1 | 309285 | Rupees Three Hundred Nine Thousand Two Hundred Eighty Five Only | 309285 |
| 238 | K-10 | Careful pulling out of existing cable from Main LV panel to LT-5, ELT-1 and MCC panel of 4C-240 sqmm Cu/XLPE/PVC power cable with associated ECC from existing indoor/outdoor cable trays, vertical risers, and under-floor UPVC sleeves/handholes; including safe disconnecting, sealing of cable ends using waterproof PVC insulation tape or heat-shrinkable end caps to prevent moisture ingress, coiling/drumming, transportation, and safe stacking/handing over at the client's designated storage location within the facility premises. | Job | 1 | 556713 | Rupees Five Hundred Fifty Six Thousand Seven Hundred Thirteen Only | 556713 |
| 239 | K-11 | Careful dismantling, relocation, and re-installation of the existing 60kVA Automatic Transfer Switch (ATS) DB from its current position to a new location designated by the client. The scope of work includes marking/tagging of existing wires, safe electrical disconnection, structural unmounting, safe transit within the facility premises, rigid wall or floor mounting at the new location, extending/rerouting existing power/control cables if necessary, proper dressing, re-termination using appropriate copper lugs and glands, testing, and final commissioning to ensure seamless functionality. | Job | 1 | 185571 | Rupees One Hundred Eighty Five Thousand Five Hundred Seventy One Only | 185571 |
| 240 | K-12 | Dismantling, relocation, reinstallation, testing and recommissioning of the existing 110 kWe Solar PV system equipment, including solar inverters, AC/DC combiner boxes, energy meters, associated accessories and cabling, from the existing location to the new inverter room as directed by the Consultant/Client. The work shall include tagging and disconnection of existing cables, dismantling, internal transportation, mounting at the new location, cable rerouting/extensions as required, termination with suitable lugs and glands, reconnection of earthing and control circuits, testing, commissioning, and handing over the complete system in fully functional condition. | Job | 1 | 247428 | Rupees Two Hundred Forty Seven Thousand Four Hundred Twenty Eight Only | 247428 |
| 241 | SECTION - L CIVIL WORKS | ||||||
| 242 | Dismantling Works | ||||||
| 243 | L-1 | Dismantling of the existing walls and floors using mechanical means and manual labour as per site requirements, including the cost of dismantling existing installations necessary to remove for dismantling and to complete the job, including the cost of disposal of debris away from premises, complete in all respects. | Cft | 650 | 178 | Rupees One Hundred Fifteen Thousand Seven Hundred Only | 115700 |
| 244 | L-2 | Dismantling of existing doors carefully without any damages, stacking them at a designated location carefully within Bank Premises, cost of all labour, tools required to complete the job successfully is included, complete in all respects. | Job | 2 | 17775 | Rupees Thirty Five Thousand Five Hundred Fifty Only | 35550 |
| 245 | Sub Flooring Works | ||||||
| 246 | L-3 | Providing, mixing, laying, vibrating & curing cement concrete 1:3:6 in floors, in trenches in required levels & slopes complete in all respects as per site requirements and as directed by the Engineer Incharge. | Cft | 480 | 948 | Rupees Four Hundred Fifty Five Thousand Forty Only | 455040 |
| 247 | L-4 | Backfilling & compaction of approved quality sand in under floors, trenches, etc. including breaking clods, dressing, watering, compaction etc, complete in all respects as per site requirements and as directed by the Engineer In-Charge. | Cft | 250 | 237 | Rupees Fifty Nine Thousand Two Hundred Fifty Only | 59250 |
| 248 | L-5 | Providing, mixing, laying, vibrating & curing RCC 1:2:4 in foundation beam and columns for gate using SR cement, including the cost of required formwork, including the cost of using mechanical vibrator for concrete compaction as per site requirements. The contractor shall be responsible for providing fairface concrete after removing formwork, free from all defects e.g honey combing etc. Complete in all respects as per site requirements and as directed by the Engineer In-Charge | Cft | 210 | 1185 | Rupees Two Hundred Forty Eight Thousand Eight Hundred Fifty Only | 248850 |
| 249 | L-6 | Providing, straightening, cutting, bending and binding of grade-60 deformed steel bars in beams, columns, foundations etc. including the cost of required binding wire, spacers etc. complete in all respects as per site requirements and as directed by the Engineer In-Charge | Kg | 400 | 593 | Rupees Two Hundred Thirty Seven Thousand Two Hundred Only | 237200 |
| 250 | L-7 | Providing, mixing, laying, vibrating & curing cement concrete 1:2:4 cost of required formwork, in required levels & slopes, including the cost of concrete pouring in panels in flooring, including the cost of glass strips in floor panels, complete in all respects as per site requirements and as directed by the Engineer Incharge. | Cft | 600 | 1185 | Rupees Seven Hundred Eleven Thousand Only | 711000 |
| 251 | Masonry & Plaster Works | ||||||
| 252 | L-8 | Providing & laying 6 inch thick block masonry having minimum compressive strength of 700 psi in walls with 1:4 cement-sand mortar including cost of precast lintel, curing etc. complete in all respects as per site requirements and as directed by the Engineer incharge. | Cft | 1200 | 948 | Rupees One Million One Hundred Thirty Seven Thousand Six Hundred Only | 1137600 |
| 253 | L-9 | Providing and fixing lintel of precast beam a minimum of 6 inch high above doors as per site requirements, covering full width of wall or as diercted by the engineer incharge. | Rft | 18 | 1304 | Rupees Twenty Three Thousand Four Hundred Seventy Two Only | 23472 |
| 254 | L-10 | Providing & laying ½” to ¾” thick 1:4 cement-sand plaster including curing etc. working at any height, complete in all respects as per site requirements and as directed by the Engineer incharge. | Sft | 2600 | 237 | Rupees Six Hundred Sixteen Thousand Two Hundred Only | 616200 |
| 255 | L-11 | Providing and fixing door frames made of about 10 swg MS sheet as per existing design and pattern, including the cost of cutting, bending, grinding, fixing in position, including the cost of red oxide, including the cost of enamel paint, complete in all respects as per site requirements and as directed by the engineer incharge. | Job | 2 | 93615 | Rupees One Hundred Eighty Seven Thousand Two Hundred Thirty Only | 187230 |
| 256 | L-12 | Refixing of doors at the designated location including cost of any repairs required, complete in all respects as per site requirements and as directed by the engineer incharge. | Job | 2 | 23700 | Rupees Forty Seven Thousand Four Hundred Only | 47400 |
| 257 | L-13 | Dismantling of existing rain water pipe completely, including disposal of debris away from municipal limits, including stacking serviceable items at a designated location inside bank premises as per directions of the engineer incharge. | Job | 4 | 5925 | Rupees Twenty Three Thousand Seven Hundred Only | 23700 |
| 258 | L-14 | Providing and fixing 4 inch dia pvc pipe schedule 40, inlcuding cost of any fittings, including cost of pvc strainer, inlcuding cost of clips, nails required to fix the pipe, including the cost of providing khurrah, complete in all respects as per site requirements and as directed by the engineer incharge. | Rft | 65 | 1067 | Rupees Sixty Nine Thousand Three Hundred Fifty Five Only | 69355 |
| 259 | L-15 | Leveling/repairing of slab surface with about ¾” average thick layer of slurry comprising of Cement + Sand (in 1:3 ratio) using latex based concrete bonding agent from Sika, ICPL, Fospak or other approved manufacturer @ 3 liters per bag of cement or as per the directions of the manufacturer/ supplier, smooth trowel finished top surface, curing with damp jute cloth, complete in all respects as per site requirements and as directed by the Engineer In-Charge. | Sft | 2030 | 104 | Rupees Two Hundred Eleven Thousand One Hundred Twenty Only | 211120 |
| 260 | L-16 | Making of PCC edge fillet (triangular/parabolic shape gola) of approximately 4” x 4” size along the outer walls with plain cement in 1:2:4 ratio using OP cement, clean sand and coarse aggregate of 10mm and down sizes mixed with latex based bonding agent SBR from Sika, ICPL, Fospak or other approved manufacturer @ 3 liters per bag of cement or as per the directions of the manufacturer/ supplier with smooth trowel finished top surface, curing, complete in all respects as per site requirements and as directed by the Engineer In-Charge. | Rft | 110 | 115 | Rupees Twelve Thousand Six Hundred Fifty Only | 12650 |
| 261 | L-17 | Providing and torch applying 4mm thick layer of modified bitumen & non-woven spun-bond polyester fibers reinforcement based water proofing membrane of Derma Bit (ECOGUM SP) or other approved equivalent KSA make, with slated type top surface finish, in accordance with the directions of the manufacturer/supplier including the cost of approved primer (DERMAPRIMER or other approved equivalent) applied @ about 4m2/liter or as recommended by the manufacturer, all required overlaps of minimum 3” width, complete in all respects as per site requirements and as directed by the Engineer In-Charge. Measurement for payment shall be made on the basis of top surface only without considering any overlaps. (The contractor shall have to submit samples along with technical data sheets of materials for approval by the Engineer In-Charge before application at site.) | Sft | 2030 | 415 | Rupees Eight Hundred Forty Two Thousand Four Hundred Fifty Only | 842450 |
| 262 | Paint Works | ||||||
| 263 | L-18 | Providing & applying two coats of plastic emulsion paint of Burger Robbialac or other approved equivalent over walls & ceiling application of wall putty, sand papering, etc. complete in all respects as per site requirements and as directed by the Engineer In-charge. | Sft | 6700 | 107 | Rupees Seven Hundred Sixteen Thousand Nine Hundred Only | 716900 |
| 264 | L-19 | Providing & applying two coats of weather coat paint of Burger Robbialac or other approved equivalent over walls , application of wall putty, sand papering, etc. complete in all respects as per site requirements and as directed by the Engineer In-charge. | Sft | 2800 | 119 | Rupees Three Hundred Thirty Three Thousand Two Hundred Only | 333200 |
| 265 | L-20 | Providing and applying enamel paint of nippon or approved equivalent on doors, ventilators and anyother metal frame as directed by the engineer incharge. | Sft | 1000 | 143 | Rupees One Hundred Forty Three Thousand Only | 143000 |
| 266 | L-21 | Providing and fixing 100 x 100 x 10mm angle along the edge of the cable trench, including the cost of enamel paint on angle, complete in all respects as per site requirements and as directed by the engineer incharge. | Rft | 110 | 2489 | Rupees Two Hundred Seventy Three Thousand Seven Hundred Ninety Only | 273790 |
| 267 | L-22 | Providing and fixing precast RCC slabs over cable trench having varying widths of 2 ft, 2.5 ft and 4 ft. Each slab must have two hooks at top for ease of lifting, minimum width of slab be about 1 ft, minimum thickness of slab is about 4 inch, with about 2 bars at top and 2 bars at bottom of 3/8" steel, with distribution steel as well, complete in all respects. payment will be made on top surface area of slab. | Sft | 180 | 1422 | Rupees Two Hundred Fifty Five Thousand Nine Hundred Sixty Only | 255960 |
| GRAND TOTAL: | Rs 240,285,841.00 |
For Individual Jobs
| # | Job Title | Quantity | Unit Price (PKR) | Total Price (PKR) | Delivery Location | Delivery Period / Year | Country of Origin |
|---|---|---|---|---|---|---|---|
| 1 | |||||||
| 2 |
| # | Lot Title | Total Lot Price (PKR) | Country of Origin |
|---|---|---|---|
| 1 | [Lot 1 Title] |
The following Special Conditions of Contract shall supplement the General Conditions of Contract. Whenever there is a conflict, the provisions herein shall prevail over those in the Conditions of Contract. The corresponding clause number of the GCC is indicated in parentheses.
Number of GC Clause
Amendments of, and Supplements to, Clauses in the General Conditions of Contract
Number of GC Clause 1
Definitions
The Procuring Agency is: SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
The Supplier is:
The title of the subject procurement is: UPGRADATION AND IMPROVEMENT OF ELECTRICAL SYSTEM AT SBP BSC (BANK) NORTH NAZIMABAD
Number of GC Clause 2
Applicable/Governing Law:
The Contract shall be interpreted in accordance with the laws of Islamic Republic of Pakistan
Number of GC Clause 3
Language:
The language of the Contract, all correspondence and communications to be given, and all other documentation to be prepared and supplied under the Contract shall be in English.
Number of GC Clause 4
Notices:
The addresses for the notices are:
Procuring Agency:
SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer
SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
+92-315-720-2000
akhtar.munir@sbp.org.pk
Contractor/ Bidder:
[Name, address and telephone number]
The Contractor/ Bidder’s Representative(s)
[Name, address, telephone number and e-mail address]
Number of GC Clause 6.1
The Authorized Representatives are:
For the Procuring Agency:
SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer
SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
+92-315-720-2000
akhtar.munir@sbp.org.pk
For the Bidder:
Name: ………………………………………
Designation: ……………………..
Address: …………………………………………..
Number of GC Clause 7
Effectiveness of the contract
The Contractor/Bidder shall be effective within ….. days from the date of signature of the Contract by both parties
Number of GC Clause 8
Commencement of Contract:
The Contractor/Bidder shall provide Non-Consultancy Services from the effective date of contract.
Number of GC Clause 10.2
Expiration of Contract:
The time period shall be ……………………………
Number of GC Clause 14
Termination
In the event of termination of the contract due to any reason as already defined in the General Conditions of Contract, the Bidder shall be responsible for providing to the Authority the Goods till the time of alternate arrangements.
Number of GC Clause 16
Conflict of Interest:
The Procuring Agency reserves the right to determine on a case-by-case basis whether the Bidder should be disqualified from providing goods or services due to a conflict of a nature described in Clause GCC 17.
Number of GC Clause 20
Liquidated Damages
If the Bidder fails to provide services as required under the contract or in case of any data loss/data breach or any incident compromising the data security or other such failures related to any services, the Bidder shall pay to the Procuring Agency as Liquidated Damages at a rate of 0.10% to 10.00% of the Contract value, in accordance with the extent of performance failure & the cost of investigating such incidents as judged by the Authority.
Number of GC Clause 21
Performance Guarantee:
The amount of performance guarantee shall be 10.00% of the contract price in acceptable form of Pay Order, Banker's Cheque, Call at Deposit, Bank Guarantee, Demand Draft
Number of GC Clause 27
Currency of Payment:
All the payment to be released to the contractor/Bidder shall be in Pakistani Rupees.
Number of GC Clause 28
Payment terms:
Payment will be made to the Bidder against the procured Goods and services according to the actual invoice or running bills submitted by the Bidder against the services provided within the time given in the conditions of the contract.
Number of GC Clause 29
Identifying Defects:
The Authority reserves the right at any time to inspect the premises of the provider to inspect the goods and monitor the goods being provided.
For being Brand New, bearing relevant reference numbers of the equipment (Certificate from supplier)
For Physical Fitness having No Damages (Certificate from supplier)
For the Country of Origin as quoted by the Supplier (Certificate from manufacturer)
For conformance to specifications and performance parameters, through Prior to delivery inspection (Inspection Report by Procurement Committee / Inspection Team)
For successful operation at site after complete installation, testing and commissioning of the equipment (Installation, Testing and Commissioning Report by Procurement Committee / Inspection Team)
Copies of the Supplier’s invoice showing Goods’ description, quantity, unit price, and total amount;
Original and two copies of the usual transport document (for example, a negotiable bill of lading, a non-negotiable sea waybill, an inland waterway document, an air waybill, a railway consignment note, a road consignment note, or a multimodal transport document) which the buyer may require to take the goods;
Copies of the packing list identifying contents of each package;
Insurance Certificate;
Manufacturer’s or Supplier’s Valid Warranty Certificate;
Inspection Certificate issued by the Nominated Inspection Agency (if any), and the Supplier’s Factory Inspection Report;
Certificate of Origin.
The above documents would be required even if the equipment has already been imported and is available with the supplier ex-stock
Number of GC Clause 31
Following is the guidance for Dispute Resolution
Notwithstanding any reference to the arbitration herein, the parties shall continue to perform their respective obligations under the Contract.
Rules of procedure for arbitration proceedings:
Any dispute between the Authority and a Bidder shall be referred to arbitration under the laws of Pakistan including Arbitration Act 1940.
Place of Arbitration and Award:
The arbitration shall be conducted in English language and place shall be Islamabad. The award shall be final and binding.
Date: [insert date (as day, month and year)]
Bid No.:P103714
To: SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
We, the undersigned, declare that:
We understand that, according to your conditions, Bids must be supported by a Bid Securing Declaration.
We accept that we will be blacklisted and henceforth cross debarred for participating in respective category of public procurement proceedings for a period of (not more than) six months, if fail to abide with a bid securing declaration, however without indulging in corrupt and fraudulent practices, if we are in breach of our obligation(s) under the Bid conditions, because we:
We understand this Bid Securing Declaration shall expire if we are not the successful
Bidder, upon the earlier of (i) our receipt of your notification to us of the name of the successful Bidder; or (ii) twenty-eight (28) days after the expiration of our Bid.
THIS AGREEMENT made the _____ day of __________ 20_____ between SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
(hereinafter called “the Procuring Agency”) of the one part and [name of Bidder] of [city and country of Bidder] (hereinafter called “the Bidder”) of the other part:
WHEREAS the Procuring Agency invited Bids for provision of goods, viz., UPGRADATION AND IMPROVEMENT OF ELECTRICAL SYSTEM AT SBP BSC (BANK) NORTH NAZIMABAD (P103714) and has accepted a Bids by the Bidder for the provision of Goods in the sum of [contract price in words and figures] (hereinafter called “the Contract Price”).
NOW THIS CONTRACT WITNESSETH AS FOLLOWS:
1. In this Contract words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to.
2. The following documents shall be deemed to form and be read and construed as part of this Contract, In the event of any ambiguity or conflict between the Contract Documents listed below, the order of precedence shall be the order in which the Contract Documents are listed below:-
3. In consideration of the payments to be made by the Procuring Agency to the Bidder as hereinafter mentioned, the Bidder hereby covenants with the Procuring Agency to provide the Goods related services and to remedy defects therein in conformity in all respects with the provisions of the Contract.
4. The Procuring Agency hereby covenants to pay the Bidder in consideration of the provision of Goods and the remedying of defects therein, the Contract Price or such other sum as may become payable under the provisions of the contract at the times and in the manner prescribed by the contract.
IN WITNESS whereof the parties hereto have caused this Contract to be executed in accordance with their respective laws the day and year first above written.
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Procuring Agency:
………………………………………………
Signed, sealed, delivered by __________________the ________________ (for the Procuring Agency)
Witness to the signatures of the Bidder: …………………………………………………
Contract Number: Contract Value: Contract Title:
Dated:
[Name of Supplier] hereby declares that it has not obtained or induced the procurement of any contract, right, interest, privilege or other obligation or benefit from Government of Pakistan or any administrative subdivision or agency thereof or any other entity owned or controlled by it (GoP) through any corrupt business practice.
Without limiting the generality of the foregoing [Name of Supplier] represents and warrants that it has fully declared the brokerage, commission, fee etc. paid or payable to anyone and not given or agreed to give and shall not give or agree to give to anyone within or outside Pakistan either directly or indirectly through any natural or juridical person, including its affiliate, agent, associate, broker, consultant, director, promoter, shareholder, sponsor or subsidiary, any commission, gratification, bribe, finder's fee or kickback, whether described as consultations fee or otherwise, with the object of obtaining or inducing the procurement of a contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP, except that which has been expressly declared pursuant hereto.
[Name of Supplier] certifies that it has made and will make full disclosure of all agreements and arrangements with all persons in respect of or related to the transaction with GoP and has not taken any action or will not take any action to circumvent the above declaration, representative or warranty.
[Name of Supplier] accepts full responsibility and strict liability for making and false declaration, not making full disclosure, misrepresenting fact or taking any action likely to defeat the purpose of this declaration, representation and warranty. It agrees that any contract, right interest, privilege or other obligation or benefit obtained or procured as aforesaid shall, without prejudice to any other right and remedies available to GoP under any law, contract or other instrument, be voidable at the option of GoP.
Notwithstanding any rights and remedies exercised by GoP in this regard, [Name of Supplier] agrees to indemnify GoP for any loss or damage incurred by it on account of its corrupt business practices and further pay compensation to GoP in an amount equivalent to ten time the sum of any commission, gratification, bribe, finder's fee or kickback given by [Name of Supplier] as aforesaid for the purpose of obtaining or inducing the procurement of any contract, right, interest, privilege or other obligation or benefit in whatsoever form from GoP.
To: SBP-BSC North (SBP Banking Services Corporation (BSC)), Senior Officer SBP BSC (Bank) Building Shahrah-e-Noor Jahan North Nazimabad,, North Nazimabad Sub-Division, Karachi Central (District), Karachi (Division), Sindh (Province).
WHEREAS [name of Bidder] (hereinafter called “the Bidder”) has undertaken, in pursuance of Contract No. [reference number of the contract] dated [insert date] for provision of Goods(hereinafter called “the Contract”).
AND WHEREAS it has been stipulated by you in the said Contract that the Bidder shall furnish you with a Bank Guarantee by a reputable bank for the sum specified therein as security for compliance with the Bidder’s performance obligations in accordance with the Contract.
AND WHEREAS we have agreed to give the Bidders guarantee:
THEREFORE, WE hereby affirm that we are Guarantors and responsible to you, on behalf of the Bidder, up to a total of [amount of the guarantee in words and figures], and we undertake to pay you, upon your first written demand declaring the Bidder to be in default under the Contract and without cavil or argument, any sum or sums within the limits of [amount of guarantee] as aforesaid, without your needing to prove or to show grounds or reasons for your demand or the sum specified therein.
This guarantee is valid until the: [insert date]
Signature and seal of the Guarantors
_____________________________________________________________________
[name of bank or financial institution]
_____________________________________________________________________
[address]
_____________________________________________________________________
[date}
Annexure-02 - Section VIII - SCC (Part-B).pdf
Annexure-3-Formula for Price Adjustment.pdf